AUMA_SGExC05.1-12.1_muszaki_adatok_1f_angol
-
Upload
raja-prathap-singh -
Category
Documents
-
view
220 -
download
4
Transcript of AUMA_SGExC05.1-12.1_muszaki_adatok_1f_angol
1) Tripping torque adjustable for both directions2) Permissible average torque for the whole travel of 90°.3) Weight for part-turn actuator AUMA NORM with 1-phase AC motor, standard electrical connection, unbored coupling and handwheel.4) Based on 20 °C ambient temperature and at an average load with running torque.5) PTC thermistors require additionally a suitable tripping device in the controls.6) According to EN 60079-14 a thermal overload relay (e.g. motor protection switch) must be installed for explosion-proof actuators in addition to the thermoswitches.
Type Operating timefor 90°
in seconds
Torque range 1) Runningtorque 2)
Valve attachment Valve shaft Handwheel
50/60 Hzmin.Nm
max.Nm
max.Nm
StandardEN ISO
5211
OptionEN ISO
5211Cylindricalmax. mm
Squaremax. mm
Two-flatmax. mm Ø mm
Turnsfor 90°
appr.kg3)
SGExC 05.1 4 – 32 100 150 75 F 05 F 07 25.4 22 22 160 58 19
SGExC 07.1 8 – 63 120 300 150 F 07 F 10 25.4 22 22 160 58 19
SGExC 10.1 16 – 125 250 600 300 F 10 F 12 38 30 27 160 107 25
SGExC 12.1 22 – 180 500 840 420 F 12 F 14 50 36 41 160 110 29
General informationPart-turn actuators AUMA NORM require external controls. AUMA offers actuator controls AUMA MATIC AMExC or AUMATICACExC. These can also easily be mounted to the actuator at a later date.Features and functionsExplosion protection Standard: II2G EEx de IIC T4
II2G c IIC T4Option: II2G EEx d IIC T4
II2G c IIC T4EC type examination certificate PTB 01 ATEX 1119Types of explosion protection Motor compartment: d flameproof enclosure EEx d
Switch compartment: d flameproof enclosure EEx dTerminal compartment: e increased safety EEx e (optional d)
Type of duty 4) Short-time duty S2 - 10 minMotors 1-ph AC motor, type IM B14 according to IEC 34Insulation class F, tropicalizedMotor protection Standard: PTC thermistors (according to DIN 44082)5)
Option: Thermoswitches (NC)6)
Self-locking yesSwing angle Standard: 80° to 110° adjustable between min. and max. value.
Options: 30° – 40°, 40° – 55°, 55° – 80°, 110° – 160°, 160° – 230° or 230° – 320°Swing angle Counter gear mechanism for end positions CLOSED and OPEN
Standard: Single switch (1 NC and 1 NO) for each end positionOptions: Tandem switch (2 NC and 2 NO) for each end position, switches galvanically isolated
Triple switch (3 NC and 3 NO) for each end position, switches galvanically isolatedIntermediate position switch (DUO limit switching), available for any intermediateposition
Torque switching Adjustable torque switching for direction OPEN and CLOSEStandard: Single switch (1 NC and 1 NO) for each directionOptions: Tandem switch (2 NC and 2 NO) for each direction, switches galvanically isolated
Non-intrusive setting (option) Magnetic limit and torque transmitter MWG(only possible in combination with actuator controls AUMATIC)
Position feedback signal,analogue (options)
Potentiometer or 0/4 – 20 mA (RWG)For further details see separate data sheet
Torque feedback signal,analogue (option)
Only in combination with magnetic limit and torque transmitter MWG and controlsAUMATIC
Mech. position indicator Continuous indication, adjustable indicator disc with symbols OPEN and CLOSEDRunning indication (option) Blinker transmitterHeater in switch compartment Standard: self-regulating PTC heater, 5 – 20 W, 110 – 250 V AC/DC
Options: 24 – 48 V AC/DC or 380 – 400 V ACA resistance type heater (5 W, 24 V DC) is installed in the actuator in combination with theactuator controls AMExC oder ACExC.
Motor heater (option) 12.5 W
Technical data AUMA part-turn actuators for open-close dutywith 1-phase AC motors
SGExC 05.1 – SGExC 12.1AUMA NORM
Issue 1.05Y003.812/002/en
We reserve the right to alter data according to improvements made. Previous data sheets become invalid with the issue of this data sheet.
Page 1 of 2
Manual operation Manual drive for setting and emergency operation, handwheel does not rotate duringelectric operation.Option: Handwheel lockable
Electrical connection Standard: Ex-plug/socket connector with terminal board KP (screw type connection)Options: Ex-plug-in terminal connection
Double SealedThreads for cable glands Standard: Metric threads
Options: Pg-threads, NPT-threads, G-threadsTerminal plan KMS 1TP 200/001 (basic version)Splined coupling for connectionto the valve shaft
Standard: Coupling without boreOptions: Machined coupling with bore and keyway, square bore or bore with two-flats
according to EN ISO 5211Valve attachment Dimensions according to EN ISO 5211Service conditionsEnclosure protection accordingto EN 60 5297)
Standard: IP 67Options: IP 68For both enclosure protections (IP 67 and IP 68) the terminal compartment is additionallysealed against the interior - double sealed
Corrosion protection Standard: KN Suitable for installation in industrial units, in water- or power plantswith a low pollutant concentration
Options: KS Suitable for installation in occasionally or permanently aggressiveatmosphere with a moderate pollutant concentration (e.g. in waste-water treatment plants, chemical industry)
KX Suitable for installation in extremely aggressive atmosphere with highhumidity and high pollutant concentration
KX-G same as KX, however aluminium-free version (outer parts)Finish coating Standard: two-component iron-mica combinationColour Standard: silver-grey (DB 701, similar to RAL 9007)
Option: Other colours are possible on requestAmbient temperature 8) Standard: – 20 °C to + 40 °C
Options: – 40 °C to + 40 °C (low temperature)– 50 °C to + 40 °C (extreme low temperature)
Lifetime
Other informationEC directives ATEX directive: (94/9/EC)
Electromagnetic Compatibility (EMC): (89/336/EEC)Low Voltage Directive: (73/23/EEC)Machinery Directive: (98/37/EC)
Reference documents Product description "Electric part-turn actuators SG"Information “Electric actuators and valve gearboxes according to ATEX directive...”Dimension sheets SGExCElectrical data sheets SGExC
SGExC 05.1 – SGExC 12.1AUMA NORM
Issue 1.05Y003.812/002/en
Technical data AUMA part-turn actuators for open-close dutywith 1-phase AC motors
We reserve the right to alter data according to improvements made. Previous data sheets become invalid with the issue of this data sheet.
Page 2 of 2
Type Operating cycles (OPEN-CLOSE-OPEN) for 90°
SGExC05.1 20,000SGExC07.1 20,000SGExC10.1 15,000SGExC12.1 10,000
7) For version in enclosure protection IP 68 higher corrosion protection KS or KX is strongly recommended.8) Under certain conditions (special sizing) up to + 60 °C possible. Version with RWG from – 40 °C to + 40 °C (+ 60 °C)