Page 1: August 2007 - Prefco-HVAC Catalog 2-04 v4.pdf · Series 5000 5000 Application Series 5000 multi-blade fire dampers are UL555 fire dampers that can be either static or dynamic rated.

August 2007

Page 2: August 2007 - Prefco-HVAC Catalog 2-04 v4.pdf · Series 5000 5000 Application Series 5000 multi-blade fire dampers are UL555 fire dampers that can be either static or dynamic rated.

Mutliblade Fire DampersSeries 5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Model 5000Model 5003

Combination Fire + Smoke DampersSeries 5050 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Model 5050-1Model 5050-2Model 5050-3

Series 5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5Model 5053-1Model 5053-2Model 5053-3

Series 5050 TC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6Model 5050 TC-1Model 5050 TC-2

Smoke DampersSeries 5150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Model 5150-1Model 5150-2Model 5150-3

Pressure Drop Information and Actuators . . . . . . . . .8

Curtain DampersSeries 5500 E4 / DE4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

5500 E4 A5500 E4 A35500 E4 BC5500 E4 BC35500 E4 C5500 E4 C35500 E4 CR5500 E4 CR35500 E4 CO5500 E4 CO35500 E4 ML5500 E4 ML35500 DE4 A5500 DE4 A35500 DE4 BC5500 DE4 BC35500 DE4 C5500 DE4 C35500 DE4 CR5500 DE4 CR35500 DE4 CO5500 DE4 CO35500 DE4 ML5500 DE4 ML3

Series 5500 E6 / DE6 . . . . . . . . . . . . . . . . . . . . . . . . . . . .105500 E6 LPB5500 E6 BC5500 E6 CR5500 E6 CO5500 E6 LPC5500 E6 M5500 E6 ML5500 DE6 LPB5500 DE6 BC5500 DE6 CR5500 DE6 CO5500 DE6 LPC5500 DE6 M5500 DE6 ML

Series 5500 E8 / DE8 . . . . . . . . . . . . . . . . . . . . . . . . . . . .115500 E8 CR5500 E8 CO5500 E8 LPC5500 E8 M5500 E8 ML5500 DE8 CR5500 DE8 CO5500 DE8 LPC5500 DE8 M5500 DE8 ML

Series 5500 E2 / DE2 . . . . . . . . . . . . . . . . . . . . . . . . . . . .125500 E2 A5500 DE2 A

Series 5500 SF / DSF . . . . . . . . . . . . . . . . . . . . . . . . . . . .135500 SF M5500 DSF LPB5500 DSF 2 1/25500 SF1.5 A5500 DSF1.5 A

Radiation DampersSeries 5600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

5600 / 5600EF5610 / 5610EF5650 / 5650EF5673 / 5673EF5660 / 5660EF5680 / 5680EF

Butterfly / Single Blade Fire DampersSeries 5600F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

5600F5600F35630F5650F5650F35660F5660F3

Table of Contents

About Prefco®

Prefco is a leading brand of Life-Safety Fire, Smoke, and Ceiling Radiation dampers. We are dedicated to providing the best serviceof any manufacturer serving the HVAC market today. Manufactured by Perfect Air Control, Inc., Prefco is an industry leader in the in-novation and development of these important HVAC components.

Our products are designed, manufactured, and tested in compliance with appropriate UL Standards for Safety as well as many stateand international standards.

The Prefco brand is sold throughout the United States as well as Canada, South America, the Far East, and Middle East through abroad network of representatives, distributors, and licensees, knowledgeable in all phases of HVAC design.

In the interest of product development, Prefco reserves the right to make changes without notice.

©2004 Perfect Air Control, Inc. • All Rights Reserved • 1310 N. Hercules Ave. • Clearwater, FL 33765 • (800) 437-6653 • (727) 443-7167 Fax • www.prefco-hvac.com

Page 3: August 2007 - Prefco-HVAC Catalog 2-04 v4.pdf · Series 5000 5000 Application Series 5000 multi-blade fire dampers are UL555 fire dampers that can be either static or dynamic rated.

Series 5000 5000

Application

Series 5000 multi-blade fire dampers are UL555 fire dampers that can be eitherstatic or dynamic rated. When applied in a dynamic (fans on) system, thisdamper has been evaluated with bi-directional airflow, and is rated to 3000 FPMand 4" static pressure in compliance with UL555 6th edition.

Series 5000 meets or complies with the following as a fire damper:• CA State Fire Marshall Fire listing #3225-1518:100

• NFPA 90A & B

• All major building codes, including BOCA, ICBO/UBC, SBCCI & the ICC International Code

UL Listings – File #R6189

• Model 5000 - UL555 1 1/2 Hour Fire Static or Dynamic

• Model 5003 - UL555 3 Hour Fire Static or Dynamic

Options & Accessories

❑ Dual Blade Position Indicator Switches (Switch#1)

❑ Factory Supplied Sleeves – 18 or 14 Gauge, 18" or 24" deep (For other gauges and depths, contact your local rep)

❑ Factory supplied ‘EZ Mount’ mounting angles

❑ Single or Dual Blade stiffeners - for strength & stability of wider units in high pressure systems

Standard Construction

• Frame4" Wrap around full channel frame – 16 GA Galvanized Steel

• Blades22 GA Galvanized Steel, Modified Triple-V Design

• BearingsIntegral Curl in Frame Design

• Linkage14 GA Galvanized, on Blade Type (in airstream)

• Heat Responsive DeviceFusible Link 165°F standard, 212°, 250° or 350°F optional

Typical Pressure Drop Per Duct Velocity

• Pressure drop information is from a 24" x 24" damper. • Pressure drop through a smaller damper will be higher.

Duct Velocity (FPM) 500 600 700 800 900 1000 1250 1500 1750 2000 3000 4000

Full Open .010 .013 .015 .021 .030 .035 .040 .067 .080 .100 .250 .480Pressure Drop / Inches of Water

Model 5000 Standard Sizes

Type Fire RatingMin. Vertical or

HorizontalMax.

VerticalMax

Horizontal

Static 1 1/2 HR Fire 6" x 6" 120" x 84" 144" x 90"

Dynamic 1 1/2 HR Fire 6" x 6" 36" x 45" 36" x 45" Dampers will be fabricated 1/4" under ordered dimensions unless otherwise specified.

Model 5003 Standard Sizes

Type Fire Rating Min. Vertical Max Vertical

Static 3 Hour Fire 6" x 6" 30" x 30"

Dynamic 3 Hour Fire 6" x 6" 30" x 30"Dampers will be fabricated 1/4" under ordered dimensions unless otherwise specified.

Multiblade Fire DampersFor Use in Static or Dynamic Systems

Available Models

Model Description

5000 1 1/2 HR Fire

5003 3 HR Fire

A dim. is always width of blades

©2004 Perfect Air Control, Inc. • All Rights Reserved • 1310 N. Hercules Ave. • Clearwater, FL 33765 • (800) 437-6653 • (727) 443-7167 Fax • www.prefco-hvac.com

Page 4: August 2007 - Prefco-HVAC Catalog 2-04 v4.pdf · Series 5000 5000 Application Series 5000 multi-blade fire dampers are UL555 fire dampers that can be either static or dynamic rated.

Series 5050

©2004 Perfect Air Control, Inc. • All Rights Reserved • 1310 N. Hercules Ave. • Clearwater, FL 33765 • (800) 437-6653 • (727) 443-7167 Fax • www.prefco-hvac.com

5050

Application

Series 5050 is a combination fire & smoke damper with a 1 1/2 Hour UL555 firerating available with your choice of Class I, II, or III UL555S Leakage rating. Thisdamper utilizes a thermally responsive electric switch to allow for the return springof the specified actuator to close the damper upon elevated temperature. Thedamper may be installed vertically or horizontally for use in barriers requiring bothfire and leakage protection. This damper has been evaluated with bi-directional air-flow, and is rated to 2000 FPM and 4" static pressure in compliance with UL555 6thedition and UL555S 4th edition.

Series 5050 meets or complies with the following as a smoke, fire or combination fire & smoke damper:• CA State Fire Marshall Fire listing #3225-1518:100

Leakage listing #3230-1518:106

• NFPA 90A & B, 92A & B

• All major building codes, including BOCA, ICBO/UBC, SBCCI & the ICC International Code

Models 5050-1 / 5050-2 / 5050-3 UL Listings – File #R6189• UL555 1 1/2 Hour Fire

• UL555S Class I/II/III @ 250°F or 350°F

Series 5050 Standard SizesSee actuator section, pg. 8 for internal mount minimums and pressure drop information

Fire Rating Leakage RatingMin. Verticalor Horizontal

Max. VerticalMax Horizon-

tal

1 1/2 Hour Fire Class I/II/III @ 250°F 6" x 6" 120" x 84" 144" x 90"

1 1/2 Hour Fire Class I/II/III @ 350°F 6" x 6" 120" x 84" 144" x 90"

Dampers will be fabricated 1/4" under ordered dimensions unless otherwise specified.

Combination Fire & Smoke Dampers1 1/2 Hour Class I/II/III Leakage

For Use in Static or Dynamic Systems

Standard Construction

• Frame4" Wrap around full channel frame – 16 GA Galvanized Steel

• Blades22 GA Galvanized Steel , Modified Triple-V Design

• BearingsIntegral Curl in Frame Design

• Linkage14 GA Galvanized, on Blade Type (in airstream)

• SealsCompression type silicone seals (Class I/II ONLY)

• Heat Responsive DeviceElectric-Thermal Disc, 165°F standard, 212°, 250° or 350°F

optional

• SealantUL Certified silicone caulk (sleeved units only)

Available ModelsModel Description

5050-1 / Class I 1 1/2 HR Fire5050-2 / Class II 1 1/2 HR Fire

5050-3 / Class III 1 1/2 HR Fire

A dim. is always width of blades

Options & Accessories

❑ Dual Blade Position Indicator Switches (Switch#1)

❑ Factory Supplied Sleeves – 18 or 14 Gauge, 18" or 24" deep (For other gauges and depths, contact your local rep. Dampers with external mounted actuators are available with a 18 gauge side plate, if no factory sleeve is desired)

❑ Factory supplied ‘EZ Mount’ mounting angles

❑ Single or Dual Blade stiffeners - for strength & stability of wider units in high pressure systems

Internally mounted actuator

Page 5: August 2007 - Prefco-HVAC Catalog 2-04 v4.pdf · Series 5000 5000 Application Series 5000 multi-blade fire dampers are UL555 fire dampers that can be either static or dynamic rated.

Series 5053

©2004 Perfect Air Control, Inc. • All Rights Reserved • 1310 N. Hercules Ave. • Clearwater, FL 33765 • (800) 437-6653 • (727) 443-7167 Fax • www.prefco-hvac.com

5053Application

Series 5053 is a combination fire & smoke damper with a 3 Hour UL555 fire rat-ing available with your choice of Class I, II, or III UL555S Leakage rating. This damper utilizes a thermally responsive electric switch to allow for the returnspring of the specified actuator to close the damper upon elevated temperature.The damper may be installed vertically for use in barriers requiring both fire andleakage protection. This damper has been evaluated with bi-directional airflow, andis rated to 2000 FPM and 4" static pressure in compliance with UL555 6th editionand UL555S 4th edition.

Series 5053 meets or complies with the following as a smoke, fire or combina-tion fire & smoke damper:• CA State Fire Marshall Fire listing #3225-1518:100

Leakage listing #3230-1518:106

• NFPA 90A & B, 92A & B

• All major building codes, including BOCA, ICBO/UBC, SBCCI & the ICC International Code

UL Listings – File #R6189• UL555 3 Hour Fire

• UL555S Class I/II/III @ 250°F or 350°F

Options & Accessories

❑ Dual Blade Position Indicator Switches (Switch#1)

❑ Factory Supplied Sleeves – 18 or 14 Gauge, 18" or 24" deep (For other gauges and depths, contact your local rep. Dampers with external mounted actuators are available with a 18 gauge side plate, if no factory sleeve is desired)

❑ Factory supplied ‘EZ Mount’ mounting angles

❑ Single or Dual Blade stiffeners - for strength & stabilityof wider units in high pressure systems

Standard Construction

• Frame4" Wrap around full channel frame – 16 GA Galvanized Steel

• Blades22 GA Galvanized Steel , Modified Triple-V Design

• BearingsIntegral Curl in Frame Design

• Linkage14 GA Galvanized, on Blade Type (in airstream)

• SealsCompression type silicone seals (Class I/II ONLY)

• Heat Responsive DeviceElectric-Thermal Disc, 165°F standard, 212°, 250° or 350°F optional

• SealantUL Certified silicone caulk (sleeved units only)

Combination Fire & Smoke Dampers3 Hour Class I/II/III LeakageFor Use in Static or Dynamic Systems

Series 5053 Standard SizesSee actuator section, pg. 8 for internal mount minimums and pressure drop information

Fire Rating Leakage Rating Min. Vertical Max. Vertical

3 Hour Fire Class I/II/III @ 250°F 6" x 6" 30" x 30"

3 Hour Fire Class I/II/III @ 350°F 6" x 6" 30" x 30"

Dampers will be fabricated 1/4" under ordered dimensions unless otherwise specified.

Available ModelsModel Description

5053-1 / Class I 3 HR Fire

5053-2 / Class II 3 HR Fire5053-3 / Class III 3 HR Fire

A dim. is always width of blades

Page 6: August 2007 - Prefco-HVAC Catalog 2-04 v4.pdf · Series 5000 5000 Application Series 5000 multi-blade fire dampers are UL555 fire dampers that can be either static or dynamic rated.

Series 5050 TC 50

50 T

CApplication

Series 5050TC is a combination fire and smoke damper that is UL classified forinterior tunnel corridor ceiling penetrations. When installed in a tunnel-type corri-dor ceiling, the damper assembly carries a 1 hour UL555 fire rating and a ClassI/II UL555S leakage rating.

This damper also can be applied as a standard fire and smoke damper. It may bemounted horizontally or vertically, is approved for bi-directional airflow, and israted to 2000 FPM and 4" static pressure in compliance with UL555 6th editionand UL555S 4th edition.

Series 5050TC meets or complies with the following as a corridor smoke, fire orcombination fire & smoke damper:• CA State Fire Marshall Fire listing #3225-1518:100

Leakage listing #3230-1518:106

• NFPA 90A & B, 92A & B

• All major building codes, including BOCA, ICBO/UBC, SBCCI & the ICC International Code

UL Listings – File #R6189• UL555 1 Hour Fire Corridor - 1 1/2 Hour Fire Wall / Floor

• UL555S Class I/II @ 250°F or 350°F

Options & Accessories

❑ Dual Blade Position Indicator Switches (Switch#1)

❑ Factory Supplied Sleeves – 18 or 14 Gauge, 18" or 24"deep

(For other gauges and depths, contact your local rep)

❑ Factory supplied ‘EZ Mount’ mounting angles

❑ Single or Dual Blade stiffeners - for strength & stability ofwider

units in high pressure systems

Standard Construction

• Frame4" Wrap around full channel frame – 16 GA Galvanized Steel

• Blades22 GA Galvanized Steel, Modified Triple-V Design

• BearingsIntegral Curl in Frame Design

• Linkage14 GA Galvanized, on Blade Type (in airstream)

• SealsCompression type silicone seals

• Heat Responsive DeviceElectric-Thermal Disc, 165°F standard, 212°, 250° or 350°F optional

• SealantUL Certified silicone caulk (sleeved units only)

Series 5050 TC Standard SizesSee actuator section, pg. 8 for internal mount minimums and pressure drop information

Application Fire Rating Leakage Rating Min. Vert. or Horiz. Max Vert. Max Horiz.

Corridor 1 Hour Class I / II @ 250°F 6" x 6" N/A 24" x 24"

Corridor 1 Hour Class I / II @ 350°F 6" x 6" N/A 24" x 24"

Fire/Smoke 1 1/2 Hour Class I / II @ 250°F 6" x 6" 24" x 24" 24" x 24"

Fire/Smoke 1 1/2 Hour Class I / II @ 350°F 6" x 6" 24" x 24" 24" x 24"

Dampers will be fabricated 1/4" under ordered dimensions unless otherwise specified.

Combination Fire& Smoke Dampers

For Tunnel Corridor Applications For Use in Static or Dynamic Systems

A dim. is always width of blades

Externally mounted actuator

Internally mounted actuator

Available ModelsModel Description

5050TC-1 / Class I 1 1/2 HR Fire

5050TC-2 / Class II 1 1/2 HR Fire

©2004 Perfect Air Control, Inc. • All Rights Reserved • 1310 N. Hercules Ave. • Clearwater, FL 33765 • (800) 437-6653 • (727) 443-7167 Fax • www.prefco-hvac.com

Page 7: August 2007 - Prefco-HVAC Catalog 2-04 v4.pdf · Series 5000 5000 Application Series 5000 multi-blade fire dampers are UL555 fire dampers that can be either static or dynamic rated.

Series 5150

©2004 Perfect Air Control, Inc. • All Rights Reserved • 1310 N. Hercules Ave. • Clearwater, FL 33765 • (800) 437-6653 • (727) 443-7167 Fax • www.prefco-hvac.com

5150

Application

Series 5150 is a UL555S approved Smoke damper available for Class I, II, orIII. Series 5150 can utilize a variety of internally or externally mounted actu-ators. The damper may be installed vertically or horizontally in ducts pene-trating barriers requiring leakage protection, within 24" of the barrier beingprotected. This damper has been evaluated with bi-directional airflow, andis rated to 2000 FPM and 4" static pressure in compliance UL555S 4th edi-tion.

Series 5150 meets or complies with the following as a smoke damper:• CA State Fire Marshall Leakage listing #3230-1518:106

• NFPA 90A & B, 92A & B

• All major building codes, including BOCA, ICBO/UBC, SBCCI & the ICC International Code

UL Listings – File #R6189

• UL555S Class I/II/III @ 250°F or 350°F

Options & Accessories

❑ Dual Blade Position Indicator Switches (Switch#1)

❑ Factory Supplied Sleeves – 18 or 14 Gauge, 18" or 24" deep (For other gauges and depths, contact your local rep. Dampers with external mounted actuators are available with a 18 gauge side plate, if no factory sleeve is desired)

❑ Factory supplied ‘EZ Mount’ mounting angles

❑ Single or Dual Blade stiffeners - for strength & stability of wider units in high pressure systems

Standard Construction

• Frame4" Wrap around full channel frame – 16 GA Galvanized Steel

• Blades22 GA Galvanized Steel , Modified Triple-V Design

• BearingsIntegral Curl in Frame Design

• Linkage14 GA Galvanized, on Blade Type (in airstream)

• SealsCompression type silicone seals (Class I/II ONLY)

• SealantUL Certified silicone caulk (sleeved units only)

Smoke DampersClass I/II/III LeakageFor Use in Static or Dynamic Systems

Series 5150 Standard SizesSee actuator section, pg. 8 for internal mount minimums and pressure drop information

Leakage RatingMin. Verticalor Horizontal

Max. Vertical or Horizontal

Class I/II/III @ 250°F 6" x 6" 144" x 96" or 288" x 48"

Class I/II/III @ 350°F 6" x 6" 144" x 96" or 288" x 48"

*Dampers will be fabricated 1/4" under ordered dimensions unless otherwise specified.

Available ModelsModel

5150-1 / Class I5150-2 / Class II5150-3 / Class III

A dim. is always width of blades

Page 8: August 2007 - Prefco-HVAC Catalog 2-04 v4.pdf · Series 5000 5000 Application Series 5000 multi-blade fire dampers are UL555 fire dampers that can be either static or dynamic rated.

Series 5050, 5053, 5050 TC and 5150 Pressure Drop

Series 5050, 5053, 5050 TC and 5150 Actuators

©2004 Perfect Air Control, Inc. • All Rights Reserved • 1310 N. Hercules Ave. • Clearwater, FL 33765 • (800) 437-6653 • (727) 443-7167 Fax • www.prefco-hvac.com

Specifications

Actuators will be mounted externally on the right side unless otherwise specified.Actuators available for internal or external mount (all must be factory mounted):

* Damper must be at least 13" in height for actuator to mount internally.* Unit must be 10" or greater in width for any internal actuator mounting orientation.* The factory will mount the actuator parallel to the damper, whenever height allows,

unless otherwise specified.

Actuator Model Voltage (AC)Power Consumption

Running Holding

Belimo FSNF120 120 0.23A, 18W 0.09A, 6W

Belimo FSNF24 24 24VA 24VA

Honeywell ML4115 120 0.18A, 18W 0.11A, 9W

Honeywell ML8115 24 16VA 8VA

Honeywell MS4209F, MS4309F 120 0.25A, 23W 0.13A, 7W

Honeywell MS8209F, MS8309F 24 23VA 7VA

Honeywell MS4120F 120 0.35A, 35W 0.15A, 10W

Honeywell MS8120F 24 45VA 10VA

Mounting Configurations

Actuator Mounted Parallel to the dampe

(140)

(98)

(259)

(110)

(102)

Actuator Mounted perpendicular to the damper

*Available Down ToMin Height

(140)

(270)

(98)

(259)

(102)

Actuator Mounted Parallel to the damp

(140)

(84)

(272)

(111)

(102)

Actuator Mounted

perpendicular to the damper

*Available Down To

Min Height

(140)

(292)

(84)

(272)

(102)

Actuator Mounted Parallel to the damper

(140)

(57)

(191)

(122)

(102)

Actuator Mounted perpendicular to the damper

*Available Down ToMin Height

(140)

(233)

(130)

(191)

(43)

(102)

*Damper height must be at least 18"for actuator to mount internally.

*Damper height must be at least 18"for actuator to mount internally.

*Damper height must be at least 13"for actuator to mount internally.

Typical Pressure Drop Per Duct Velocity

Pressure drop information is from a 24" x 24" damper. Pressure drop through a smaller damper will be higher.

Duct Velocity (FPM) 500 600 700 800 900 1000 1250 1500 1750 2000 3000 4000

Full Open .010 .013 .015 .021 .030 .035 .040 .067 .080 .100 .250 .480

Pressure Drop / Inches of Water

Page 9: August 2007 - Prefco-HVAC Catalog 2-04 v4.pdf · Series 5000 5000 Application Series 5000 multi-blade fire dampers are UL555 fire dampers that can be either static or dynamic rated.

Series 5500 E4/ DE4

©2004 Perfect Air Control, Inc. • All Rights Reserved • 1310 N. Hercules Ave. • Clearwater, FL 33765 • (800) 437-6653 • (727) 443-7167 Fax • www.prefco-hvac.com

E4/D

E4

Standard Construction

• FrameWrap-around frame - 21 GA Galvanized Steel

• Blades - Low ProfileRoll Formed - 21 GA Galvanized Steel

• Closure Springs (Horizontal Models)Stainless Steel Constant Force Coil

• Fusible Link - UL-33UL Listed 165 F (standard), 212 F (optional) McCabe Link (optional)

UL555 1 1/2 Hour Fire - Static

5500 E4

A V or H Type A - Frame and blades within airstream

BC V or H Type B - Blades removed from airstream via cap

CR V or H Type C - Frame blades removed from airstream sq. to round

CO V or H Type C - Frame and blades are removed from airstream sq. to oval

C V or H Type C - Frame and blades are removed from airstream

M V or H Flanged frame, oversized 2" from duct removes frame and partial blades from airstream

ML V or H Slip connection oversized 2" from duct removes frame and partial blades from airstream

UL555 3 Hour Fire - Dynamic

5500DE4

A3 V Type A - Frame and blades within airstream

BC3 V Type B - Blades removed from airstream via cap

CR3 V Type C - Frame blades removed from airstream sq. to round

CO3 V Type C - Frame and blades are removed from airstream sq. to oval

C3 V Type C - Frame and blades are removed from airstream

M3 V Flanged frame, oversized 2" from duct removes frame and partial blades from airstream

ML3 V Slip connection oversized 2" from duct removes frame and partial blades from airstream

UL555 1 1/2 Hour Fire - Dynamic

5500DE4

A V or H Type A - Frame and blades within airstream

BC V or H Type B - Blades removed from airstream via cap

CR V or H Type C - Frame blades removed from airstream sq. to round

CO V or H Type C - Frame and blades are removed from airstream sq. to oval

C V or H Type C - Frame and blades are removed from airstream

M V or H Flanged frame, oversized 2" from duct removes frame and partial blades from airstream

ML V or H Slip connection oversized 2" from duct removes frame and partial blades from airstream

UL555 3 Hour Fire - Static

5500 E4

A3 V Type A - Frame and blades within airstream

BC3 V Type B - Blades removed from airstream via cap

CR3 V Type C - Frame blades removed from airstream sq. to round

CO3 V Type C - Frame and blades are removed from airstream sq. to oval

C3 V Type C - Frame and blades are removed from airstream

M3 V Flanged frame, oversized 2" from duct removes frame and partial blades from airstream

ML3 V Slip connection oversized 2" from duct removes frame and partial blades from airstream

Application

Series 5500 E4 or DE4 curtain fire dampers are UL Classified for installation in walls,floors, and partitions requiring a fire damper. Series 5500 E4 or DE4 is available witha UL555 Listing of either 1 1/2 or 3 hours. These dampers may be installed verticallyor horizontally in static (5500 E4) or dynamic (5500 DE4) systems.

Series 5500 E4 or DE4 meets or complies with the following as a fire damper:• NFPA Standards

• All major building codes including BOCA, ICBO/UBC, SBCCI, and ICC International Code

• BS 476:Part 8; 20 & 22; ISO/DIS 834-1 & 10294-1 PREN 1366-2 Internationally Tested 4 hour

• CA State Fire Marshall - #3225-1518-101

UL Listing – File #R6189• UL555 Listing 1 1/2 or 3 Hour Static (5500 E4)

• UL555 Listing 1 1/2 or 3 Hour Dynamic (5500 DE4)

Curtain Fire Dampers (4” Frame)For Use in Static or Dynamic Systems

Page 10: August 2007 - Prefco-HVAC Catalog 2-04 v4.pdf · Series 5000 5000 Application Series 5000 multi-blade fire dampers are UL555 fire dampers that can be either static or dynamic rated.

Series 5500 E6/DE6

©2004 Perfect Air Control, Inc. • All Rights Reserved • 1310 N. Hercules Ave. • Clearwater, FL 33765 • (800) 437-6653 • (727) 443-7167 Fax • www.prefco-hvac.com

E6/

DE

6

Standard Construction

• Blades - Low ProfileRoll Formed - 21 GA Galvanized Steel

• Closure Springs (Horizontal Models)Stainless Steel Constant Force Coil

• Fusible Link - UL-33UL Listed 165 F (standard), 212 F (optional)McCabe Link (optional).

Curtain Fire Dampers (6” Frame)

For Use in Static or Dynamic Systems

UL555 1 1/2 Hour Fire - Static

5500 E6

LPB V or H Type A - Frame and blades within airstream

BC V or H Type B - Blades removed from airstream via cap

CR V or H Type C - Frame blades removed from airstream sq. to round

CO V or H Type C - Frame and blades are removed from airstream sq. to oval

LPC V or H Oversized 2" from duct removes frame and partial blades from airstream

M V or H Flanged frame, oversized 2" from duct removes frame and partial blades from airstream

ML V or H Slip connection oversized 2" from duct removes frame and partial blades from airstream

UL555 1 1/2 Hour Fire - Dynamic

5500 DE6

LPB V or H Type A - Frame and blades within airstream

BC V or H Type B - Blades removed from airstream via cap

CR V or H Type C - Frame blades removed from airstream sq. to round

CO V or H Type C - Frame and blades are removed from airstream sq. to oval

LPC V or H Oversized 2" from duct removes frame and partial blades from airstream

M V or H Flanged frame, oversized 2" from duct removes frame and partial blades from airstream

ML V or H Slip connection oversized 2" from duct removes frame and partial blades from airstream

Application

Series 5500 E6 or DE6 curtain fire dampers are UL Classified for installation inwalls, floors, and partitions with a fire rating of less than 3 hours. These dampersmay be installed vertically or horizontally in static (5500 E6) or dynamic (5500DE6) systems.

Series 5500 E6 or DE6 meets or complies with the following as a fire damper• NFPA Standards

• All major building codes including BOCA, ICBO/UBC, SBCCI, and ICC International Code

• BS 476: Part 8; 20 & 22; ISO/DIS 834-1 & 10294-1PREN 1366-2 Internationally Tested 4 hour

• CA State Fire Marshall - #3225-1518-101

UL Listing – File #R6189• UL555 Listing 1 1/2 Hour Static (5500 E6)

• UL555 Listing 1 1/2 Hour Dynamic (5500 DE6)

Page 11: August 2007 - Prefco-HVAC Catalog 2-04 v4.pdf · Series 5000 5000 Application Series 5000 multi-blade fire dampers are UL555 fire dampers that can be either static or dynamic rated.

Series 5500 E8/DE8

©2004 Perfect Air Control, Inc. • All Rights Reserved • 1310 N. Hercules Ave. • Clearwater, FL 33765 • (800) 437-6653 • (727) 443-7167 Fax • www.prefco-hvac.com

E8/D

E8

Application

Series 5500 E8 or DE8 curtain fire dampers are UL Classified for installation inwalls, floors, and partitions with a fire rating of less than 3 hours. These dampersmay be installed vertically or horizontally in static (5500 E8) or dynamic (5500DE8) systems. The 8” frame allows for installation without the use of an additionsleeve.

Series 5500 E8 or DE8 meets or complies with the following as a fire damper:• NFPA Standards

• All major building codes including BOCA, ICBO/UBC, SBCCI, and ICC International Code

• BS 476:Part 8; 20 & 22; ISO/DIS 834-1 & 10294-1PREN 1366-2 Internationally Tested 4 hour

• CA State Fire Marshall - #3225-1518-101

UL Listing – File #R6189• UL555 Listing 1 1/2 Hour Static (5500 E8)

• UL555 Listing 1 1/2 Hour Dynamic (5500 DE8)

Standard Construction

• Blades - Low ProfileRoll Formed - 21 GA Galvanized Steel

• Closure Springs (Horizontal Models)Stainless Steel Constant Force Coil

• Fusible Link - UL-33UL Listed 165 F (standard), 212 F (optional)McCabe Link (optional)

Curtain Fire Dampers (8” Frame)For Use in Static or Dynamic Systems

UL555 1 1/2 Hour Fire - Static

5500 E8

CR V or H Type C - Frame blades removed from airstream sq. to round

CO V or H Type C - Frame and blades are removed from airstream sq. to oval

LPC V or H Oversized 2" from duct removes frame and partial blades from airstream

M V or H Flanged frame, oversized 2" from duct removes frame and partial blades from airstream

ML V or H Slip connection oversized 2" from duct removes frame and partial blades from airstream

UL555 1 1/2 Hour Fire - Dynamic

5500 DE8

CR V or H Type C - Frame blades removed from airstream sq. to round

CO V or H Type C - Frame and blades are removed from airstream sq. to oval

LPC V or H Oversized 2" from duct removes frame and partial blades from airstream

M V or H Flanged frame, oversized 2" from duct removes frame and partial blades from airstream

ML V or H Slip connection oversized 2" from duct removes frame and partial blades from airstream

Page 12: August 2007 - Prefco-HVAC Catalog 2-04 v4.pdf · Series 5000 5000 Application Series 5000 multi-blade fire dampers are UL555 fire dampers that can be either static or dynamic rated.

Series 5500 E2/DE2

©2004 Perfect Air Control, Inc. • All Rights Reserved • 1310 N. Hercules Ave. • Clearwater, FL 33765 • (800) 437-6653 • (727) 443-7167 Fax • www.prefco-hvac.com

E2/

DE

2Application

Series 5500 E2 or DE2 curtain fire dampers are UL Classified for installation inwalls, floors, and partitions with a fire rating of less than 3 hours. These dampersmay be installed vertically or horizontally in static (5500 E2) or dynamic (5500DE2) systems.

Series 5500 E2 or DE2 meets or complies with the following as a fire damper:• NFPA Standards

• All major building codes including BOCA, ICBO/UBC, SBCCI, and ICC International Code

• BS 476:Part 8; 20 & 22; ISO/DIS 834-1 & 10294-1 PREN 1366-2 Internationally Tested 4 hour

• CA State Fire Marshall - #3225-1518-101

UL Listing – File #R6189• UL555 Listing 1 1/2 Hour Static (5500 E2)

UL555 Listing 1 1/2 Hour Dynamic (5500 DE2)

Standard Construction

• Blades - Low ProfileRoll Formed - 21 GA Galvanized Steel

• Closure Springs (Horizontal Models)Stainless Steel Constant Force Coil

• Fusible Link - UL-33UL Listed 165 F (standard), 212 F (optional)McCabe Link (optional)

Curtain Fire Dampers(2” Frame - “Thin-Line”)

For Use in Static Systems or Dynamic Systems

UL555 1 1/2 Hour Fire - Static

5500 E2 A V or H Type A - Frame and blades within airstream

UL555 1 1/2 Hour Fire - Dynamic

5500 DE2 A V or H Type A - Frame and blades within airstream

Page 13: August 2007 - Prefco-HVAC Catalog 2-04 v4.pdf · Series 5000 5000 Application Series 5000 multi-blade fire dampers are UL555 fire dampers that can be either static or dynamic rated.

Series 5500 SF/DSF

©2004 Perfect Air Control, Inc. • All Rights Reserved • 1310 N. Hercules Ave. • Clearwater, FL 33765 • (800) 437-6653 • (727) 443-7167 Fax • www.prefco-hvac.com

SF

/DS

F

For more product information visit us at www.prefco-hvac.com

13

Application

Series 5500 SF or DSF curtain fire dampers are UL Classified for installation inwalls, floors, and partitions with a fire rating of less than 3 hours. These dampersmay be installed vertically or horizontally in static (5500 SF) or dynamic (5500DSF) systems.

Series 5500 SF or DSF meets or complies with the following as a fire damper:• NFPA Standards

• All major building codes including BOCA, ICBO/UBC, SBCCI, and ICC International Code

• CA State Fire Marshall - #3225-1518-101

UL Listing – File #R6189• UL555 Listing 1 1/2 Hour Static (5500 SF)

• UL555 Listing 1 1/2 Hour Dynamic (5500 DSF)

Standard Construction

• Blades - Full Length Hinge 21 GA Galvanized Steel

• Closure Springs Stainless Steel

• Fusible Link - UL-33UL Listed 212F (standard) 165 F (optional)McCabe Link (optional)

Curtain Fire Dampers (“Sub Frame”)For Use in Static Systems or Dynamic Systems

4 1/2” Wide Blade - “Sub” Frame

UL555 1 1/2 Hour Fire - Static

5500 SF LPB V or H Type A - Frame and blades within airstream

UL555 1 1/2 Hour Fire - Dynamic

5500 DSF LPB V or H Type A - Frame and blades within airstream

2 1/2” Wide Blade - “Sub” Frame

UL555 1 1/2 Hour Fire - Static

5500 SF 2 1/2 V or H Type A - Frame and blades within airstream

UL555 1 1/2 Hour Fire - Dynamic

5500 DSF 2 1/2 V or H Type A - Frame and blades within airstream

1 1/2” Wide Blade - “Sub” Frame

UL555 1 1/2 Hour Fire - Static

5500 SF 1 1/2 V or H Type A - Frame and blades within airstream

UL555 1 1/2 Hour Fire - Dynamic

5500 DSF 1 1/2 V or H Type A - Frame and blades within airstream

Page 14: August 2007 - Prefco-HVAC Catalog 2-04 v4.pdf · Series 5000 5000 Application Series 5000 multi-blade fire dampers are UL555 fire dampers that can be either static or dynamic rated.

Series 5600

©2004 Perfect Air Control, Inc. • All Rights Reserved • 1310 N. Hercules Ave. • Clearwater, FL 33765 • (800) 437-6653 • (727) 443-7167 Fax • www.prefco-hvac.com

5600

Application

Series 5600 provide fire and heat radiation protection of HVAC penetrations infloor/ceiling and roof/ceiling assemblies with restrained or unrestrained ratings of ei-ther 2 or 3 hours. Standard fire dampers (1 1/2 or 3 hr) do not provide the requiredheat protection for ceiling penetrations.

Series 5600 meets or complies with the following as a ceiling radiation damper:• NFPA Standards

• All major building codes including BOCA, ICBO/UBC, SBCCI, and ICC International Code

• CA State Fire Marshall - #3225-1518-103

UL Listing – File #R7365• UL555C Listing 2 or 3 Hour

Standard Construction

• Frame21 GA Galvanized Steel

• Blades - Full Length Hinge 21 GA Galvanized Steel

• Closure Springs Stainless Steel

• Fusible Link - UL-33UL Listed 212F (standard) 165 F (optional)McCabe Link (optional)

• Blade InsulationCeramic fiber

Ceiling Radiation Dampers

Series 5600

Round Butterfly

5600 H Un-insulated - 2 Hours

5600EF H Un-insulated - 2 Hours, w/extended flange

5610 H Insulated - 3 Hours

5610EF H Insulated - 3 Hours, w/extended flange

Square/Rectangular Butterfly

5660 H Un-insulated - 2 Hours

5660EF H Un-insulated - 2 Hours, w/extended flange

5680 H Insulated - 3 Hours

5680EF H Insulated - 3 Hours, w/extended flange

Square/Rectangular Single Blade

5650 H Un-insulated - 2 Hours

5650EF H Un-insulated - 2 Hours, w/extended flange

5673 H Insulated - 3 Hours

5673EF H Insulated - 3 Hours, w/extended flange

Page 15: August 2007 - Prefco-HVAC Catalog 2-04 v4.pdf · Series 5000 5000 Application Series 5000 multi-blade fire dampers are UL555 fire dampers that can be either static or dynamic rated.

Series 5600F

©2004 Perfect Air Control, Inc. • All Rights Reserved • 1310 N. Hercules Ave. • Clearwater, FL 33765 • (800) 437-6653 • (727) 443-7167 Fax • www.prefco-hvac.com

5600F

For more product information visit us at www.prefco-hvac.com

15

Application

Series 5600F fire damper is UL Classified for installation inwalls, floors, and partitions available with a UL555 Listing ofeither 1 1/2 or 3 hours. This damper may be installed verti-cally or horizontally in static HVAC systems that automaticallyshut down in the event of fire

Series 5600F meets or complies with the following as a firedamper:• NFPA Standards

• All major building codes including BOCA,ICBO/UBC, SBCCI, and ICC International Code

• CA State Fire Marshall - #3225-1518-101

UL Listing – File #R6189• UL555 Listing 1 1/2 or 3 Hour

Standard Construction

• Frame21 GA Galvanized Steel

• Blades - Full Length Hinge 21 GA Galvanized Steel

• Closure Springs Stainless Steel

• Fusible Link - UL-33UL Listed 212F (standard) 165 F (optional)McCabe Link (optional)

Butterfly/Single Blade Fire Dampers

Series 5600 F

Round Butterfly

5600F V or H 1 1/2 hours

5600F3 V 3 hours

Round Single Blade

5630F V 1 1/2 hours

Square/Rectangular Butterfly

5660F V or H 1 1/2 hours

5660F3 V 3 hours

Square/Rectangular Single Blade

5650F V or H 1 1/2 hours

5650F3 V 3 hours

Page 16: August 2007 - Prefco-HVAC Catalog 2-04 v4.pdf · Series 5000 5000 Application Series 5000 multi-blade fire dampers are UL555 fire dampers that can be either static or dynamic rated.

©2007 Perfect Air Control, Inc. • All Rights Reserved • 1310 N. Hercules Ave. • Clearwater, FL 33765 • (800) 437-6653 • (727) 443-7167 Fax • www.prefco-hvac.com

Perfect Air Control, Inc. manufactures Prefco products under one or more of the following patents.3,648,328/3,725,972/3,727,663/3,796,248/3,796,249/3,814,165/3,833,989/3,866,656/3,866,657/3,889,3143,899,156/3,960,065/3,977,456/4,040,304/4,041,570/4,074,388/4,080,978/4,081,173/4,099,292/4,113,2304,133,232/4,114,656/4,146,048/4,241,748/4,263,930/4,295,486/4,185,658/4,472,999/4,442,862/4,372,3424,338,967/4,301,569/4,219,185/4,474,167/4,372,485/4,195,384/4,200,954/4,213,227/4,287,638/3,273,6823,327,764/4,219,041/4,183,129/4,185,657/4,277,870/4,304,427/4,404,990/4,390,123/4,494,449/RE 323623,401,734/3,580,160/3,605,603 Other Patents Pending. Also Patented in other countries.

Prefco-Johnson Tech Air Control Inc. manufactures Prefco products under one or more of the following patents.3,648,328/3,725,972/3,727,663/3,796,248/3,796,249/3,814,165/3,833,989/3,866,656/3,866,657/3,889,3143,899,156/3,960,065/3,977,456/4,040,304/4,041,570/4,074,388/4,080,978/4,081,173/4,099,292/4,113,2304,133,232/4,114,656/4,146,048/4,241,748/4,263,930/4,295,486/4,185,658/4,472,999/4,442,862/4,372,3424,338,967/4,301,569/4,219,185/4,474,167/4,372,485/4,195,384/4,200,954/4,213,227/4,287,638/3,273,6823,327,764/4,219,041/4,183,129/4,185,657/4,277,870/4,304,427/4,404,990/4,390,123/4,494,449/RE 323623,401,734/3,580,160/3,605,603 Other Patents Pending. Also Patented in other countries.