ATEX Compliant Diaphragm Pumps - Versa-Maticvm.salesmrc.com/pdfs/vmATEX_bro-rev0914_lowres.pdf2...

4
Versa-Matic SOLUTIONS V E R S A M AT I C . C O M Chemical Transfer Mine Dewatering Food Processing Metal Finishing Ship Cleaning ATEX Versa-Matic ® Pumps ATEX Compliant Diaphragm Pumps Safety: Safety: ATEX compliant for safe use in potentially explosive environments Broad Broad Material Range: Material Range: ATEX models available in an extensive range of metallic and non-metallic conductive materials to handle virtually any medium safely Multiple Pump Multiple Pump Configurations: Configurations: Both leak-free bolted and clamp designs available

Transcript of ATEX Compliant Diaphragm Pumps - Versa-Maticvm.salesmrc.com/pdfs/vmATEX_bro-rev0914_lowres.pdf2...

Vers

a-Mat

icS

OLU

TIO

NS

v e r S a m a T I c . c O m

• Chemical Transfer • Mine Dewatering • Food Processing • Metal Finishing • Ship Cleaning

ATEXVersa-Matic® Pumps

ATEX Compliant Diaphragm Pumps

Safety:Safety:ATEX compliant for

safe use in potentially explosive environments

BroadBroadMaterial Range:Material Range:

ATEX models available in an extensive range of metallic and

non-metallic conductive materials to handle virtually any medium safely

Multiple PumpMultiple PumpConfigurations:Configurations:

Both leak-free bolted and clamp designs available

WWW.VERSAMATIC.COM2 D E L I V E R I N G Q UA L I T Y, I N T E R C H A N G E A B L E P U M P I N G S O LU T I O N S

ATEX (Atmosphères Explosibles) is an acronym for the standard set by the European Parliament& Council of the European Union, recognized throughout the European Community as the safety standard for equipment used in potentially hazardous environments.

Why specify ATEX Compliant Pumps? Guaranteed Spark Free Safe Operation.FACT: Flammable gasses, vapors, mist, and dust as small as .03mm are explosive safety concerns when oxygen (air) is present and ignited. Products marked with the EX hexagon symbol followed by the Group and Category of safety protection indicates that the products are compliant with Directive 94/9/EC, according to Annex VIII.

Recognize the Components of ATEX Compliant Pumps.

NOTE: *See materials chart on back page for specific model details or consult the factory. (Grounding Strap sold separately - PN: 920.025.000)

CONDUCTIVE (ATEX COMPLIANT)CONDUCTIVE (ATEX COMPLIANT)• *Non-Wetted Conductive Materials:

• Conductive Acetal • Aluminum • Conductive Polypropylene • Stainless Steel

• Wetted Conductive Materials:• Conductive Acetal • Aluminum • Cast Iron • Alloy C• Conductive Polypropylene • Stainless Steel

• Fully groundable

• No isolated metallic hardware components

• Electrostatic discharges are dissipated in a continual current path throughout the pump to a natural ground

• Electrically conductive materials of construction

• ATEX Compliant means SAFE for use of equipment in potentially explosive environments, Zone 1 (gases) and Zone 21 (dusts), Gas Group IIB

ATEX SAFETY BENEFITSATEX SAFETY BENEFITS

ATEX Compliant Diaphragm PumpsKnow the Importance & Recognize the Components

WHAT IS ATEX?WHAT IS ATEX?

WWW.VERSAMATIC.COM 3

ATEX

D E L I V E R I N G Q UA L I T Y, I N T E R C H A N G E A B L E P U M P I N G S O LU T I O N S

NOTE: *See materials chart on back page for specific model details or consult the factory. (Grounding Strap sold separately - PN: 920.025.000)

WHAT IS ATEX?WHAT IS ATEX?

Versa-Matic® Metallic and Non-Metallic Pumps fully comply with ATEX requirements.

I M2 cII 3/2 GD c T5–Metallic II 3/2 GD c T6–Non-Metallic

Date of Issue:

10 May 2014

Technical File No.:

203104000-1410/MER

Quality System Registration No:

ISO 9001-2000

Directive:

94/9/EC 23 March 1994 Annex VIII

Conforming Apparatus:

Air-Operated Metal

Double Diaphragm Pumps for Use In Potentially

Explosive Atmospheres

Hazardous Location Applied:

1. II 3/2GD c T5*

T5fluidsupto

95°C

*Whenpumping

non-conductiv

efluidstheint

ernalsurfaces

that

contactthefl

uidarerestric

tedtoExII3G

DcT5.Theex

ternal

surfaces of the pump are still Ex II 2GD c T5.

2. I M2 c

fluidsupto95

°C

Pumps marked with equipment Category II 3/2 G

(internal 3 G / external 2 G), 2D, when used with

non-conductiv

efluids.Thep

umpsareCate

goryII2G

whenusedfor

conductiveflu

ids.

Manufacture:

Warren Rupp, Inc., A Unit of IDEX Corporation

800 North Main Street, P.O. Box 1568

Mansfield,OH

44901-1568

USA.

OnFileWith:

DEKRACertific

ationB.V.(034

4)

Meander 1051

6825 MJ Arnhem

The Netherlands

Harmonized Standards Applied:

EN 13463-1:2009 Non-Electrical Equipment

Potentially Explosive Atmospheres-Part 1 Basic

Methods and Requirements

EN 13463-5:2011 Non-Electrical Equipment for

Potentially Explosive Atmospheres-Part 5

Protection by Constructional Safety

Equipments:

1. Elima-Matic Series metal pumps for II 3/2GD c T5

2. Elima-Matic Series Cast Iron or Stainless Steel pumps

with Stainless Steel air center sections for I M2 c

We hereby certify that the equipment described above conforms with the protection requirements of Council Directive

94/9/EC of 23 March 1994 Annex VIII on the approximation of the laws of the Member States Concerning Equipment

and Protective Systems Intended for use in Potentially Explosive Atmospheres

DATE/OF REVISION/TITLE:

Dave Roseberry

29 May 2014

Engineering Manager

EC DECLARATION OF CONFORMITY

in accordance with ANNEX VIII of Directive 94/9/EC - Equipment for use in Potentially Explosive Atmospheres

VM_DofC_ATEX_Metallic_V_rev0514

Date of Issue: 10 May 2014Technical File No.: 203104000-1410/MERQuality System Registration No: ISO 9001-2000Directive:

94/9/EC 23 March 1994 Annex VIIIConforming Apparatus:

Air-Operated Conductive Polypropylene and

Conductive Acetal Double Diaphragm Pumps

for use in Potentially Explosive Atmospheres

Hazardous Location Applied: 1. II 3/2GD c T6*

T6fluidsupto80°C

*Whenpumpingnon-conductivefluidstheinternalsurfacesthat

contactthefluidarerestrictedtoExII3GDcT5.Theexternal

surfacesofthepumparestillExII2GDcT5.

Pumps marked with equipment Category II 3/2 G

(internal 3 G / external 2 G), 2D, when used with

non-conductivefluids.ThepumpsareCategoryII2G

whenusedforconductivefluids.Manufacture:

Warren Rupp, Inc., A Unit of IDEX Corporation

800NorthMainStreet,P.O.Box1568

Mansfield,OH44901-1568

USA.OnFileWith:DEKRACertificationB.V.(0344)

Meander1051

6825MJArnhem

The Netherlands Harmonized Standards Applied:

EN 13463-1:2009 Non-Electrical Equipment

PotentiallyExplosiveAtmospheres-Part1Basic

Methods and Requirements

EN13463-5:2011Non-ElectricalEquipmentfor

PotentiallyExplosiveAtmospheres-Part5

Protection by Constructional Safety Equipments:

1. Elima-Matic Series with any of the following

materials of construction are rated to II 3/2GD c T6:

Conductive Polypropylene and Conductive Acetal

fluidhousingswithAluminumorStainlessSteel

air center sectionsWe hereby certify that the equipment described above conforms with the protection requirements of Council Directive

94/9/EC of 23 March 1994 Annex VIII on the approximation of the laws of the Member States Concerning Equipment

and Protective Systems Intended for use in Potentially Explosive Atmospheres

DATE/OF REVISION/TITLE: Dave Roseberry

29 May 2014 Engineering Manager

EC DECLARATION OF CONFORMITYin accordance with ANNEX VIII of Directive 94/9/EC - Equipment for use in Potentially Explosive Atmospheres

VM_DofC_ATEX_Non-Metallic_V_rev0514

- Equipment intended for use in potentially explosive atmospheres

This safety compliance includes:• Filing a Technical Risk Assessment with a notified body. Versa-Matic files with DEKRA Certification B.V. Notified Body NO. 0344, The Netherlands Reference Number 203104000-1410/MER.

Requirements for compliance include, but are not limited to:• Accompanying all equipment and protective systems with instructions• Analysis of hazards arising from different ignition sources• Due analysis of equipment and protective systems• Marking all equipment and protective systems• Precise selection of electrically conductive materials• Filing a Declaration of Conformity with the notified body• Including the ATEX Declaration of Conformity with the packaging and shipment of every Versa-Matic ATEX Compliant pump

Versa-matic’s self-declared use of the ATEX mark and the documentation we provide is our published guarantee of compliance with the requirements of the directive and the safety of our products.

Versa-Matic self-declares complianceVersa-Matic self-declares compliance with the safety requirements accordingwith the safety requirements according to Annex VIII of EU Directive 94/9/EC.to Annex VIII of EU Directive 94/9/EC.

vmATEXbro-rev0914

VERSA-MATIC®

Warren Rupp, Inc.A Unit of IDEX Corporation800 North Main Street Mansfield, OH 44902 USA

Phone: 419.526.7296Fax: 419.526.7289www.versamatic.com

Distributed By:

© Copyright 2014 Warren Rupp, Inc. All Rights Reserved.

Versa-Matic delivers the safety of ATEX Compliance, in theVersa-Matic delivers the safety of ATEX Compliance, in the pump pump styles and materials the world demands.styles and materials the world demands.

AL = Aluminum CP = Conductive Polypropylene CI = Cast Iron P = Polypropylene SS = Stainless Steel K = PVDF H = Alloy C G = Conductive Acetal

Wilden® is a registered trade name of Wilden Pump and Engineering Company, a Dover Resources Company.

ATEX COMPLIANTI M2 cII 3/2 GD c T5–Metallic II 3/2 GD c T6–Non-Metallic

Dimensionally interchangeable with Wilden® Metallic clamp style pumps.

=

SIZE MODELS MAX FLOW Metallic MaterialsAL CI SS H

Clamped Metallic Pumps1½" E4 71 gpm (268 lpm)2" E2 185 gpm (700 lpm)3" E3 234 gpm (886 lpm)

Bolted Metallic Pumps½"a E5 12 gpm (45 lpm)¾" E7 12 gpm (45 lpm)1" E1 49 gpm (185 lpm)

1½" E4 72 gpm (273 lpm)1½" E40 123 gpm (466 lpm)2" E2 160 gpm (606 lpm)3" E3 273 gpm (1,033 lpm)

FDA Food Processing Pumps½" E5 12 gpm (45 lpm)1" E1 49 gpm (181 lpm)

1½" E4 71 gpm (268 lpm)2" E2 185 gpm (700 lpm)3" E3 234 gpm (886 lpm)

Sanitary Pumps1½" E4 86 gpm (326 lpm)2" E2 180 gpm (681 lpm)

Flap Valve Pumps2" E2 219 gpm (829 lpm)

High Pressure Pumps (2:1)1" N25 30 gpm (114 lpm)2" N50 90 gpm (341 lpm)2" E2 69 gpm (261 lpm)

Non-Metallic Pumps Non-Metallic MaterialsCP P K G

¼" E6 4 gpm (15 lpm)½" E5 11 gpm (42 lpm)1" E1 45 gpm (170 lpm)

1½" E4 72 gpm (273 lpm)