Aten NrGence Energy Intelligence PDU for Datacenters

42
ATEN NRGence Energy Intelligence PDU for Data Centers Product Catalog 2015 2016

description

Product catalog 2015-2016

Transcript of Aten NrGence Energy Intelligence PDU for Datacenters

Page 1: Aten NrGence Energy Intelligence PDU for Datacenters

ATEN NRGence™ Energy Intelligence PDU for Data CentersProduct Catalog

20152016Printed 03/2015 V1.1

© Copyright 2015 ATEN® International Co., Ltd.ATEN and the ATEN logo are trademarks of ATEN International Co., Ltd. All rights reserved. All other trademarks are the property of their respective owners.

Belgian Subsidiary

ATEN Infotech N.V. Mijnwerkerslaan 34, 3550 Heusden-Zolder, BelgiumPhone: +32-11-531543 Fax: +32-11-531544http://www.aten.eu E-mail: [email protected]

Corporate Headquarters

ATEN International Co., Ltd. 3F., No.125, Sec. 2, Datong Rd., Sijhih District., New Taipei City 221, TaiwanPhone: +886-2-8692-6789 Fax: +886-2-8692-6767 http://www.aten.com E-mail: [email protected]

Page 2: Aten NrGence Energy Intelligence PDU for Datacenters

Simply Better Connections

Page 3: Aten NrGence Energy Intelligence PDU for Datacenters

SOHO / SMB Solutions

Digital Media Matrix Solutions

Media Matrix Solutions

Media Distribution Solutions

Video Matrix Switches

Video Switches

Video Splitters

Video Extenders

Video Converters

Over IP Solutions

Control Center

KVM over IP

Serial Console Server

Power

KVM Switches

Matrix KVM

High-Density KVM

Dual Rail LCD KVM

KVM Switches

Cable KVM

Desktop KVM

Rack KVM

LCD KVM

KVM Extenders

Secure KVM

USB Solutions

Data Communications

Green Data Center

Remote Energy Control

Indoor Air Quality

HVAC Balance System

Smart Energy

Resources Pipeline Distribution

Professional A / V Solutions Green Energy Business

AV & Digital Home

Computer Accessories

Mobility

Networking

KVM & KVMP

Enterprise SolutionsAltusen ™

Note: IOGEAR brand is only available in North & South America and limited countries

Our Vision“Simply Better Connections” has always been at the heart of

the ATEN brand. It means providing innovative solutions for you

to make better connections, e�ciently and seamlessly, to the

information that you value. As a result, ATEN connects you to the

world, anytime and anywhere, by providing technologies that enable

you to share and to care. ATEN makes professional and personal life easier

and better connected.

About ATENATEN, established in 1979, specializes in connectivity management solutions for accessing and sharing technologies.

ATEN consolidates all of its products under the ATEN brand to provide a standard of consistent service under one name.

The ATEN brand consists of innovative solutions applied to IT infrastructure access management, professional

audio/video, green energy products for consumers, small/home o�ces (SOHO), small to medium sized business (SMB)

and enterprise customers.

ATEN’s Altusen™ IT infrastructure access management solutions o�er connectivity and control capabilities for SMB and

Enterprise customers that allow people to e�ectively manage IT equipment from anywhere in the world. ATEN’s

VanCryst™ professional audio/video solutions o�er signal management and system control for home and professional

audio/video installations with a variety of applications in corporate, education, government, hospitality and home

theater environments. ATEN’s NRGence™ Green Energy line o�ers sensor-enabled energy-saving hardware and

software solutions for the data center with a range of intelligent power and cooling distribution units that provide

real-time energy management and performance indicators locally and remotely.

ATEN specializes in connectivity and management solutions. We distribute our products through a global sales network

to meet a broad range of customer needs. ATEN delivers with quality and we care about our customers. We are commit-

ted to the best customer support in the industry.

Our Core Value

Caring

Integritywith pragmatism as our philosophy

Ambitionwith optimism as our attitude

Noveltywith added-value as our achievementwith respect as our spirit

VanCryst ™ NRGence ™

Consumer Electronics

Page 4: Aten NrGence Energy Intelligence PDU for Datacenters

SOHO / SMB Solutions

Digital Media Matrix Solutions

Media Matrix Solutions

Media Distribution Solutions

Video Matrix Switches

Video Switches

Video Splitters

Video Extenders

Video Converters

Over IP Solutions

Control Center

KVM over IP

Serial Console Server

Power

KVM Switches

Matrix KVM

High-Density KVM

Dual Rail LCD KVM

KVM Switches

Cable KVM

Desktop KVM

Rack KVM

LCD KVM

KVM Extenders

Secure KVM

USB Solutions

Data Communications

Green Data Center

Remote Energy Control

Indoor Air Quality

HVAC Balance System

Smart Energy

Resources Pipeline Distribution

Professional A / V Solutions Green Energy Business

AV & Digital Home

Computer Accessories

Mobility

Networking

KVM & KVMP

Enterprise SolutionsAltusen ™

Note: IOGEAR brand is only available in North & South America and limited countries

Our Vision“Simply Better Connections” has always been at the heart of

the ATEN brand. It means providing innovative solutions for you

to make better connections, e�ciently and seamlessly, to the

information that you value. As a result, ATEN connects you to the

world, anytime and anywhere, by providing technologies that enable

you to share and to care. ATEN makes professional and personal life easier

and better connected.

About ATENATEN, established in 1979, specializes in connectivity management solutions for accessing and sharing technologies.

ATEN consolidates all of its products under the ATEN brand to provide a standard of consistent service under one name.

The ATEN brand consists of innovative solutions applied to IT infrastructure access management, professional

audio/video, green energy products for consumers, small/home o�ces (SOHO), small to medium sized business (SMB)

and enterprise customers.

ATEN’s Altusen™ IT infrastructure access management solutions o�er connectivity and control capabilities for SMB and

Enterprise customers that allow people to e�ectively manage IT equipment from anywhere in the world. ATEN’s

VanCryst™ professional audio/video solutions o�er signal management and system control for home and professional

audio/video installations with a variety of applications in corporate, education, government, hospitality and home

theater environments. ATEN’s NRGence™ Green Energy line o�ers sensor-enabled energy-saving hardware and

software solutions for the data center with a range of intelligent power and cooling distribution units that provide

real-time energy management and performance indicators locally and remotely.

ATEN specializes in connectivity and management solutions. We distribute our products through a global sales network

to meet a broad range of customer needs. ATEN delivers with quality and we care about our customers. We are commit-

ted to the best customer support in the industry.

Our Core Value

Caring

Integritywith pragmatism as our philosophy

Ambitionwith optimism as our attitude

Noveltywith added-value as our achievementwith respect as our spirit

VanCryst ™ NRGence ™

Consumer Electronics

I

Page 5: Aten NrGence Energy Intelligence PDU for Datacenters

Contents

01 Metered 1U PDU

03 Metered-Switched 1U PDU

05 Outlet-Metered 1U PDU

07 Outlet-Metered-Switched 1U PDU

09 Metered Ready PDU00

13 Metered PDU (16A)

15 Metered PDU (32A)

19 Switched PDU

21 Outlet-Metered PDU

23 Outlet-Metered-Switched PDU

25 Outlet-Metered-Critical-Load PDU

PDUs for International Regions (IEC System)

PE5108G / PE5208G

PE6108G / PE6208G

PE7108G / PE7208G

PE8108G / PE8208G

PE1216G / PE1324G / PE1213G * / PE1316G *PE2220G * / PE2340G *

PE5216G * / PE5220sG *

PE5324G * / PE5324LG * PE5340sG / PE5340SLG * / PE5312sGL * / PE5312sGR *

PE6216G / PE6324G / PE6324LG *

PE7214G * / PE7216G / PE7324G *

PE8216G / PE8316G * / PE8324G *

PE9216G * / PE9222G * / PE9324G * / PE9330G *

Energy Monitoring Device

27 EC1000 / EC2004 *

Optional Accessories

33 Environment Sensors

Mounting Kits

Lok-U-Plug

* Products available on demand. Contact [email protected] for further information and the latest product availability schemes.

Energy & DCIM Management Software

29 eco Sensors

II

Page 6: Aten NrGence Energy Intelligence PDU for Datacenters

Contents

01 Metered 1U PDU

03 Metered-Switched 1U PDU

05 Outlet-Metered 1U PDU

07 Outlet-Metered-Switched 1U PDU

09 Metered Ready PDU00

13 Metered PDU (16A)

15 Metered PDU (32A)

19 Switched PDU

21 Outlet-Metered PDU

23 Outlet-Metered-Switched PDU

25 Outlet-Metered-Critical-Load PDU

PDUs for International Regions (IEC System)

PE5108G / PE5208G

PE6108G / PE6208G

PE7108G / PE7208G

PE8108G / PE8208G

PE1216G / PE1324G / PE1213G * / PE1316G *PE2220G * / PE2340G *

PE5216G * / PE5220sG *

PE5324G * / PE5324LG * PE5340sG / PE5340SLG * / PE5312sGL * / PE5312sGR *

PE6216G / PE6324G / PE6324LG *

PE7214G * / PE7216G / PE7324G *

PE8216G / PE8316G * / PE8324G *

PE9216G * / PE9222G * / PE9324G * / PE9330G *

Energy Monitoring Device

27 EC1000 / EC2004 *

Optional Accessories

33 Environment Sensors

Mounting Kits

Lok-U-Plug

* Products available on demand. Contact [email protected] for further information and the latest product availability schemes.

Energy & DCIM Management Software

29 eco Sensors

III

Page 7: Aten NrGence Energy Intelligence PDU for Datacenters

01

Metered 1U PDU PE5108G / PE5208G

PE5208G

PE5108G

44

432.4

44

432.4

PE5108G

PE5208G

FeaturesConnections• Built-in 10/100 Mbps Ethernet port• Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3

• 2-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS

• Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more

Metering• Bank level power metering and monitoring • Environment monitoring via external sensors for rack temperature and humidity readings and alerts

• Current, voltage, power, power dissipation, temperature and humidity metering with threshold settings

Outlet Switch Control• Always On

Special Features• Lok-U-Plug – easily secures power cable to PDU• 1U rack space

Page 8: Aten NrGence Energy Intelligence PDU for Datacenters

Refer to page 33 for more information.

PDUs for International Regions (IEC System) 02

Specifications

Optional Accessories

Type Part No. Description PE5108G PE5208G

Environment Sensors

EA1140 Temperature • •

EA1240 Temperature / Humidity • •

EA1340 Differential Pressure / Temperature • •

Door Sensors

EA1440 Photo Door Sensor

EA1441 Inductive Proximity Door Sensor

EA1442 Reed Door Sensor

Cable Holders2X-EA07 Lok-U-Plug Cable Holder (10 pcs per pack) • •

2X-EA08 Lok-U-Plug Installation Tool (4 pcs per pack) • •

Mounting Kits

2X-015G Double Mount Rail

2X-016G Slide Rail Kit

2X-017G Button Mount Kit

2X-018G Side Panel Mount Kit

2X-019G Side Panel Double Mount Kit

Model PE5108G PE5208G

Electrical

Nominal Input Voltage

100 – 240 VAC

Maximum Input Current

10A(Max) 16A(Max)

Input Frequency 50-60 Hz

Input Connection IEC60320 C20

Input Power 2300 VA(Max) 3680 VA(Max)

Outlet Type Total: 8 x IEC320 C13 Total: 7 x IEC320 C13 + 1 x IEC320 C19

Nominal Output Voltage

100 – 240 VAC

Maximum Output Current (Outlet)

10A(Max)C13: 10A(Max) C19: 16A(Max)

Maximum Output Current (Bank)

10A(Max) 16A(Max)

Maximum Output Current (Total)

10A(Max) 16A(Max)

Breakers 1 x 10A Non-Fuse Breaker 1 x 16A Non-Fuse Breaker

Metering Bank Level Current, Voltage, VA , PF and kWh Monitoring

Outlet Switching None

Environment Sensor Port

2

Metering Accuracy Voltage Range: 100VAC ~ 250VAC +/-1%

Power Range: 100W ~ Maximum Capacity +/- 2%Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%

Mechanical

Dimensions (H x W x D)

43.24 x 4.40 x 21.93 cm

Shipping Dimensions ( H x W x D)

53 x 14 x 31 cm

Weight /Shipping Weight

2.82 / 5.6 kg 2.79 / 5.6 kg

Power Cord Length 3 m

Environmental

Temperature (Operating / Storage)

0–50˚C / -20–60˚C

Humidity (Operating , Storage)

0–80% RH, Non-Condensing

Compliance

EMC Verification CE, Others by Request

Safety Verification TUV-CB, CE-LVD, Others by Request

Page 9: Aten NrGence Energy Intelligence PDU for Datacenters

03

Metered-Switched 1U PDU PE6108G / PE6208G

PE6208G

PE6108G

44

432.4 mm

PE6108G

PE6208G

44

FeaturesConnections• Built-in 10/100 Mbps Ethernet port• Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3

• 2-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS

• Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more

Metering• Bank level power metering and monitoring • Environment monitoring via external sensors for rack temperature and humidity readings and alerts

• Current, voltage, power, power dissipation, temperature and humidity metering with threshold settings

Outlet Switch Control• Remote power outlet control (On/Off, Power Cycle) by individual outlet or outlet groups• Supports multiple power control methods – Wake on LAN, Safe Shutdown, and Kill the Power

• Power-on sequencing – users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the correct order

Special Features• Proactive Overload Protection (POP) automatically powers off outlets when current overloads to protect connected devices

• Lok-U-Plug – easily secures power cable to PDU • 1U rack space

Page 10: Aten NrGence Energy Intelligence PDU for Datacenters

Refer to page 33 for more information.

PDUs for International Regions (IEC System) 04

Specifications

Optional Accessories

Model PE6108G PE6208G

Electrical

Nominal Input Voltage

100 – 240 VAC

Maximum Input Current

10A(Max) 16A(Max)

Input Frequency 50-60 Hz

Input Connection IEC60320 C20

Input Power 2300 VA(Max) 3680 VA(Max)

Outlet Type Total: 8 x IEC320 C13 Total: 7 x IEC320 C13 + 1 x IEC320 C19

Nominal Output Voltage

100 – 240 VAC

Maximum Output Current (Outlet)

C13: 10A(Max)C13: 10A(Max) C19: 16A(Max)

Maximum Output Current (Bank)

10A(Max) 16A(Max)

Maximum Output Current (Total)

10A(Max) 16A(Max)

Breakers 1 x 10A Non-Fuse Breaker 1 x 16A Non-Fuse Breaker

Metering Bank Level Current, Voltage, VA , PF and kWh Monitoring

Outlet Switching Yes

Environment Sensor Port

2

Metering Accuracy Voltage Range: 100VAC ~ 250VAC +/-1%

Power Range: 100W ~ Maximum Capacity +/- 2%Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%

Mechanical

Dimensions (H x W x D)

43.24 x 4.40 x 21.93 cm

Shipping Dimensions ( H x W x D)

53 x 14 x 31 cm

Weight /Shipping Weight

2.82 / 5.6 kg 2.79 / 5.6 kg

Power Cord Length 3 m

Environmental

Temperature (Operating / Storage)

0–50˚C / -20–60˚C

Humidity (Operating , Storage)

0–80% RH, Non-Condensing

Compliance

EMC Verification CE, Others by Request

Safety Verification TUV-CB, CE-LVD, GOST, Others by Request

Type Part No. Description PE6108G PE6208G

Environment Sensors

EA1140 Temperature • •

EA1240 Temperature / Humidity • •

EA1340 Differential Pressure / Temperature • •

Door Sensors

EA1440 Photo Door Sensor

EA1441 Inductive Proximity Door Sensor

EA1442 Reed Door Sensor

Cable Holders2X-EA07 Lok-U-Plug Cable Holder (10 pcs per pack) • •

2X-EA08 Lok-U-Plug Installation Tool (4 pcs per pack) • •

Mounting Kits

2X-015G Double Mount Rail

2X-016G Slide Rail Kit

2X-017G Button Mount Kit

2X-018G Side Panel Mount Kit

2X-019G Side Panel Double Mount Kit

Page 11: Aten NrGence Energy Intelligence PDU for Datacenters

05

Outlet-Metered 1U PDU PE7108G / PE7208G

PE7208G

PE7108G

44

432.4

44

432.4

PE7108G

PE7208G

FeaturesConnections• Built-in 10/100 Mbps Ethernet port• Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3

• 2-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS

• Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more

Metering• PDU and outlet level power metering and monitoring • Environment monitoring via external sensors for rack temperature and humidity readings and alerts

• Current, voltage, power, power dissipation, temperature and humidity metering with threshold settings

Outlet Switch Control• Always On

Special Features• Lok-U-Plug – easily secures power cable to PDU• 1U rack space

Page 12: Aten NrGence Energy Intelligence PDU for Datacenters

Refer to page 33 for more information.

PDUs for International Regions (IEC System) 06

Specifications

Optional Accessories

Model PE7108G PE7208G

Electrical

Nominal Input Voltage

100 – 240 VAC

Maximum Input Current

10A(Max) 16A(Max)

Input Frequency 50-60 Hz

Input Connection IEC60320 C20

Input Power 2300 VA(Max) 3680 VA(Max)

Outlet Type Total: 8 x IEC320 C13 Total: 7 x IEC320 C13 + 1 x IEC320 C19

Nominal Output Voltage

100 – 240 VAC

Maximum Output Current (Outlet)

C13: 10A(Max)C13: 10A(Max) C19: 16A(Max)

Maximum Output Current (Bank)

10A(Max) 16A(Max)

Maximum Output Current (Total)

10A(Max) 16A(Max)

Breakers 1 x 10A Non-Fuse Breaker 1 x 16A Non-Fuse Breaker

Metering Outlet Level Current, Voltage, VA , PF and kWh Monitoring

Outlet Switching None

Environment Sensor Port

2

Metering Accuracy Voltage Range: 100VAC ~ 250VAC +/-1%

Power Range: 100W ~ Maximum Capacity +/- 2%Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%

Mechanical

Dimensions (H x W x D)

43.24 x 4.40 x 21.93 cm

Shipping Dimensions ( H x W x D)

53 x 14 x 31 cm

Weight /Shipping Weight

2.87 / 5.8 kg

Power Cord Length 3 m

Environmental

Temperature (Operating / Storage)

0–50˚C / -20–60˚C

Humidity (Operating , Storage)

0–80% RH, Non-Condensing

Compliance

EMC Verification CE, Others by Request

Safety Verification TUV-CB, CE-LVD, Others by Request

Type Part No. Description PE7108G PE7208G

Environment Sensors

EA1140 Temperature • •

EA1240 Temperature / Humidity • •

EA1340 Differential Pressure / Temperature • •

Door Sensors

EA1440 Photo Door Sensor

EA1441 Inductive Proximity Door Sensor

EA1442 Reed Door Sensor

Cable Holders2X-EA07 Lok-U-Plug Cable Holder (10 pcs per pack) • •

2X-EA08 Lok-U-Plug Installation Tool (4 pcs per pack) • •

Mounting Kits

2X-015G Double Mount Rail

2X-016G Slide Rail Kit

2X-017G Button Mount Kit

2X-018G Side Panel Mount Kit

2X-019G Side Panel Double Mount Kit

Page 13: Aten NrGence Energy Intelligence PDU for Datacenters

07

Outlet-Metered-Switched 1U PDU PE8108G / PE8208G

PE8208G

PE8108G

44

432.4 mm

44PE8108G

PE8208G

FeaturesConnections• Built-in 10/100 Mbps Ethernet port• Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3

• 2-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS

• Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more

Metering• PDU and outlet level power metering and monitoring • Environment monitoring via external sensors for rack temperature and humidity readings and alerts

• Current, voltage, power, power dissipation, temperature and humidity metering with threshold settings

Outlet Switch Control• Remote power outlet control (On/Off, Power Cycle) by individual outlet or outlet groups• Outlet groups supported at the PDU level• Supports multiple power control methods – Wake on LAN, Safe Shutdown, and Kill the Power

• Power-on sequencing – users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the correct order

Special Features• Proactive Overload Protection (POP) automatically powers off outlets when current overloads to protect connected devices

• Lok-U-Plug – easily secures power cable to PDU• 1U rack space

Page 14: Aten NrGence Energy Intelligence PDU for Datacenters

PDU for International Region (IEC System) 08

Refer to page 33 for more information.

Specifications

Optional Accessories

Model PE8108G PE8208G

Electrical

Nominal Input Voltage

100 – 240 VAC

Maximum Input Current

10A(Max) 16A(Max)

Input Frequency 50-60 Hz

Input Connection IEC60320 C20

Input Power 2300 VA(Max) 3680 VA(Max)

Outlet Type Total: 8 x IEC320 C13 Total: 7 x IEC320 C13 + 1 x IEC320 C19

Nominal Output Voltage

100 – 240 VAC

Maximum Output Current (Outlet)

C13: 10A(Max)C13: 10A(Max) C19: 16A(Max)

Maximum Output Current (Bank)

10A(Max) 16A(Max)

Maximum Output Current (Total)

10A(Max) 16A(Max)

Breakers 1 x 10A Non-Fuse Breaker 1 x 16A Non-Fuse Breaker

Metering Outlet Level Current, Voltage, VA , PF and kWh Monitoring

Outlet Switching Yes

Environment Sensor Port

2

Metering Accuracy Voltage Range: 100VAC ~ 250VAC +/-1%

Power Range: 100W ~ Maximum Capacity +/- 2%Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%

Mechanical

Dimensions (H x W x D)

43.24 x 4.40 x 21.93 cm

Shipping Dimensions ( H x W x D)

53 x 14 x 31 cm

Weight /Shipping Weight

2.87 / 5.8 kg

Power Cord Length 3 m

Environmental

Temperature (Operating / Storage)

0–50˚C / -20–60˚C

Humidity (Operating , Storage)

0–80% RH, Non-Condensing

Compliance

EMC Verification CE, Others by Request

Safety Verification TUV-CB, CE-LVD, GOST, Others by Request

Type Part No. Description PE8108G PE8208G

Environment Sensors

EA1140 Temperature • •

EA1240 Temperature / Humidity • •

EA1340 Differential Pressure / Temperature • •

Door Sensors

EA1440 Photo Door Sensor

EA1441 Inductive Proximity Door Sensor

EA1442 Reed Door Sensor

Cable Holders2X-EA07 Lok-U-Plug Cable Holder (10 pcs per pack) • •

2X-EA08 Lok-U-Plug Installation Tool (4 pcs per pack) • •

Mounting Kits

2X-015G Double Mount Rail

2X-016G Slide Rail Kit

2X-017G Button Mount Kit

2X-018G Side Panel Mount Kit

2X-019G Side Panel Double Mount Kit

Page 15: Aten NrGence Energy Intelligence PDU for Datacenters

Metered Ready PDU PE1216G / PE1324G / PE1213G / PE1316G

09

FeaturesConnections Via EC1000 Energy Box• Built-in 10/100 Mbps Ethernet port • Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2&V3• Supports multi-level account and password security, IP/MAC filters, SSL 128-bit data

encryption, RADIUS• Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and

moreNote: Refer to page 27 for EC1000 product details.

Metering Via EC1000 Energy Box• Bank level current metering and monitoring

Outlet Switch Control• Always On

Special Features• Lok-U-Plug – easily secures power cable to PDU• Environment monitoring via EC1000

PE1216G

PE1324G

PE1213G

PE1316G

44

730 mm

4451.4

44

1300

1340

81.9

103.

1

44 47

44

730

44

44

13001340

4444

PE1324G

PE1216G

Page 16: Aten NrGence Energy Intelligence PDU for Datacenters

Refer to page 33 for more information.

PDUs for International Regions (IEC System) 10

Specifications

Optional Accessories

Type Part No. Description PE1216G PE1324G PE1213G PE1316G

Environment Sensors

EA1140 Temperature

EA1240 Temperature / Humidity

EA1340 Differential Pressure / Temperature

Door Sensors

EA1440 Photo Door Sensor

EA1441 Inductive Proximity Door Sensor

EA1442 Reed Door Sensor

Cable Holders2X-EA07 Lok-U-Plug Cable Holder (10 pcs per pack) • • • •

2X-EA08 Lok-U-Plug Installation Tool (4 pcs per pack) • • • •

Mounting Kits

2X-015G Double Mount Rail

2X-016G Slide Rail Kit

2X-017G Button Mount Kit

2X-018G Side Panel Mount Kit

2X-019G Side Panel Double Mount Kit

Model PE1216G PE1324G PE1213G PE1316G

Electrical

Nominal Input Voltage

100–240 VAC

Maximum Input Current

16A(Max) 32A(Max) 16A(Max) 32A(Max)

Input Frequency 50-60 Hz

Input Connection IEC60320 C20 IEC 60309 32A IEC60320 C20 IEC 60309 32A

Input Power 3680 VA(Max) 7360 VA(Max) 3680 VA(Max) 7360 VA(Max)

Outlet Type Total: 16 x IEC320 C13

Total: 24 x IEC320 C13Bank1:

Outlet 1 – 12; 12 x C13Bank2:

Outlet 13 – 24; 12 x C13

Total: 10 x IEC320 C13 + 3 x IEC320 C19

Total: 10 x IEC320 C13 + 6 x IEC320 C19

Bank1: Outlet 1 – 8; 5 x C13 + 3 x C19

Bank2: Outlet 9 – 16; 5 x C13 + 3 x C19

Nominal Output Voltage

100 – 240 VAC

Maximum Output Current (Outlet)

C13: 10A(Max)C13: 10A(Max) C19: 16A(Max)

Maximum Output Current (Bank)

16A(Max)

Maximum Output Current (Total)

16A(Max) 32A(Max) 16A(Max) 32A(Max)

Breakers 1 x 16A Non-Fuse Breaker 2 x 16A UL489 Breaker 1 x 16A Non-Fuse Breaker 2 x 16A UL489 Breaker

Metering Bank Level Current Monitoring (Via EC1000 Energy Box)

Outlet Switching None

Environment Sensor Port

0

Metering Accuracy Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%

Mechanical

Dimensions (H x W x D)

73 x 4.4 x 4.4 cm 134 x 4.4 x 4.4 cm 73 x 4.4 x 4.4 cm 134 x 4.4 x 4.4 cm

Shipping Dimensions ( H x W x D)

83 x 20.8 x 12.7 cm 148.2 x 22.4 x 17 cm 83 x 20.8 x 12.7 cm 148.2 x 22.4 x 17 cm

Weight /Shipping Weight

1.3 / 4.9 kg 3.5 / 5.9 kg 1.3 / 4.9 kg 3.5 / 5.9 kg

Power Cord Length 3 m 1.6 m 3 m 1.6 m

Environmental

Temperature (Operating / Storage)

0–50˚C / -20–60˚C

Humidity (Operating , Storage)

0–80% RH, Non-Condensing

Compliance

EMC Verification CE, C-Tick, Others by Request CE, Others by Request

Safety Verification TUV-CB, GOST, Others by Request CE-LVD, Others by Request

Page 17: Aten NrGence Energy Intelligence PDU for Datacenters

11

Metered Ready PDU PE2220G / PE2340G

PE2220G

PE2340G

FeaturesConnections Via EC2004 Energy Box• Built-in 10/100 Mbps Ethernet port• Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3

• Supports multi-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS

• Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more

Note: Refer to page 27 for EC2004 product details.

Metering Via EC2004 Energy Box• Bank level current & power metering and monitoring

Outlet Switch Control• Always On

Special Features• Lok-U-Plug – easily secures power cable to PDU• Environment monitoring and door sensors via EC2004

6644

1325

6679

.2

691.4

44

PE2220G

PE2340G

Page 18: Aten NrGence Energy Intelligence PDU for Datacenters

Refer to page 33 for more information.

PDUs for International Regions (IEC System) 12

Specifications

Optional Accessories

Type Part No. Description PE2220G PE2340G

Environment Sensors

EA1140 Temperature

EA1240 Temperature / Humidity

EA1340 Differential Pressure / Temperature

Door Sensors

EA1440 Photo Door Sensor

EA1441 Inductive Proximity Door Sensor

EA1442 Reed Door Sensor

Cable Holders2X-EA07 Lok-U-Plug Cable Holder (10 pcs per pack) • •

2X-EA08 Lok-U-Plug Installation Tool (4 pcs per pack) • •

Mounting Kits

2X-015G Double Mount Rail

2X-016G Slide Rail Kit

2X-017G Button Mount Kit • •

2X-018G Side Panel Mount Kit • •

2X-019G Side Panel Double Mount Kit

Model PE2220G PE2340G

Electrical

Nominal Input Voltage

100 – 240 VAC

Maximum Input Current

16A(Max) 32A(Max)

Input Frequency 50-60 Hz

Input Connection IEC60320 C20 IEC 60309 32A

Input Power 3680 VA(Max) 7360 VA(Max)

Outlet Type Total: 20 x IEC320 C13Total: 40 x IEC320 C13

Bank1: Outlet 1 – 20; 20 x C13Bank2: Outlet 21 – 40; 20 x C13

Nominal Output Voltage

100 – 240 VAC

Maximum Output Current (Outlet)

C13: 10A(Max)

Maximum Output Current (Bank)

16A(Max)

Maximum Output Current (Total)

16A(Max) 32A(Max)

Breakers 1 x 16A Non-Fuse Breaker 2 x 16A UL489 Breaker

Metering Bank Level Current/Voltage Monitoring (Via EC2004 Energy Box)

Outlet Switching None

Environment Sensor Port

0

Metering Accuracy Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%

Mechanical

Dimensions (H x W x D)

56.6 x 6.6 x 4.4 cm 132.5 x 6.6 x 4.4 cm

Shipping Dimensions ( H x W x D)

77.9 x 16.7 x 17.3 cm 143.3 x 24.8 x 19.4 cm

Weight / Shipping Weight

4 / 8.1 kg 4.2 / 8.4 kg

Power Cord Length 3 m 1.6 m

Environmental

Temperature (Operating / Storage)

0–40˚C / -20–60˚C

Humidity (Operating , Storage)

0–80% RH, Non-Condensing

Compliance

EMC Verification CE, Others by Request

Safety Verification TUV-CB, CE-LVD, Others by Request

Page 19: Aten NrGence Energy Intelligence PDU for Datacenters

13

Metered PDU (16A) PE5216G / PE5220sG

PE5220sG

PE5216G

FeaturesConnections• Built-in 10/100 Mbps Ethernet port• Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3

• 2-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS

• Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more

Metering• Bank level power metering and monitoring • Environment monitoring via external sensors for rack temperature and humidity readings and alerts

• Current, voltage, power, power dissipation, temperature and humidity metering with threshold settings

Outlet Switch Control• Always On

Special Features• Lok-U-Plug – easily secures power cable to PDU

1324.8 mm

6644 69 76

.4

66

691.4

44

PE5220sG

PE5216G

PE5216G

PE5220sG

Page 20: Aten NrGence Energy Intelligence PDU for Datacenters

Optional Accessories

Type Part No. Description PE5216G PE5220sG

Environment Sensors

EA1140 Temperature • •

EA1240 Temperature / Humidity • •

EA1340 Differential Pressure / Temperature • •

Door Sensors

EA1440 Photo Door Sensor

EA1441 Inductive Proximity Door Sensor

EA1442 Reed Door Sensor

Cable Holders2X-EA07 Lok-U-Plug Cable Holder (10 pcs per pack) • •

2X-EA08 Lok-U-Plug Installation Tool (4 pcs per pack) • •

Mounting Kits

2X-015G Double Mount Rail • •

2X-016G Slide Rail Kit

2X-017G Button Mount Kit •

2X-018G Side Panel Mount Kit • •

2X-019G Side Panel Double Mount Kit

Refer to page 33 for more information.

PDUs for International Regions (IEC System) 14

SpecificationsModel PE5216G PE5220sG

Electrical

Nominal Input Voltage

100 – 240 VAC

Maximum Input Current

16A(Max)

Input Frequency 50-60 Hz

Input Connection IEC60320 C20

Input Power 3680 VA(Max)

Outlet TypeTotal: 14 x IEC320 C13 + 2 x IEC320 C19Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19

Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19Total: 20 x IEC320 C13

Nominal Output Voltage

100 – 240 VAC

Maximum Output Current (Outlet)

C13: 10A(Max)C19: 16A(Max)

C13: 10A(Max)

Maximum Output Current (Bank)

16A(Max)

Maximum Output Current (Total)

16A(Max)

Breakers 1 x 16A Non-Fuse Breaker

Metering Bank Level Current, Voltage, VA , PF and kWh Monitoring

Outlet Switching None

Environment Sensor Port

2

Metering Accuracy Voltage Range: 100VAC ~ 250VAC +/-1%

Power Range: 100W ~ Maximum Capacity +/- 2%Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%

Mechanical Dimensions (H x W x D)

132.5 x 6.6 x 4.4 cm 69.1 x 6.6 x 4.4 cm

Shipping Dimensions ( H x W x D)

142 x 16 x 17 cm 77.9 x 16.7 x 17.3 cm

Weight /Shipping Weight

3.5 / 7.5 kg 2.1 / 4 kg

Power Cord Length 3 m

Environmental

Temperature (Operating / Storage)

0–40°C / -20–60°C0–50°C UL 60950

( EN 60950 de-rated 0-30˚C ) / -20–60°C

Humidity (Operating , Storage)

0–80% RH, Non-Condensing

Compliance

EMC Verification CE, C-Tick, Others by Request CE, Others by Request

Safety Verification TUV-CB, GOST, Others by Request TUV-CB, CE-LVD, Others by Request

Page 21: Aten NrGence Energy Intelligence PDU for Datacenters

15

Metered PDU (32A) PE5324G / PE5324LG

PE5324G

PE5324LG

79.2

119.

2

1775 mm

6644

6644

1775

55

PE5324LG PE5324G

FeaturesConnections• Built-in 10/100 Mbps Ethernet port• Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3

• 2-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS

• Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more

Metering• Bank level power metering and monitoring • Environment monitoring via external sensors for rack temperature and humidity readings and alerts

• Current, voltage, power, power dissipation, temperature and humidity metering with threshold settings

Outlet Switch Control• Always On

Special Features• Lok-U-Plug – easily secures power cable to PDU• Low profile dimension: PE5324LG

Page 22: Aten NrGence Energy Intelligence PDU for Datacenters

Refer to page 33 for more information.

PDUs for International Regions (IEC System) 16

Specifications

Optional Accessories

Type Part No. Description PE5324G PE5324LG

Environment Sensors

EA1140 Temperature • •

EA1240 Temperature / Humidity • •

EA1340 Differential Pressure / Temperature • •

Door Sensors

EA1440 Photo Door Sensor

EA1441 Inductive Proximity Door Sensor

EA1442 Reed Door Sensor

Cable Holders2X-EA07 Lok-U-Plug Cable Holder (10 pcs per pack) • •

2X-EA08 Lok-U-Plug Installation Tool (4 pcs per pack) • •

Mounting Kits

2X-015G Double Mount Rail • •

2X-016G Slide Rail Kit • •

2X-017G Button Mount Kit • •

2X-018G Side Panel Mount Kit • •

2X-019G Side Panel Double Mount Kit • •

Model PE5324G PE5324LG

Electrical

Nominal Input Voltage

100 – 240 VAC

Maximum Input Current

32A(Max)

Input Frequency 50-60 Hz

Connection IEC 60309 32A

Input Power 7360 VA(Max)

Outlet Type

Total: 21 x IEC320 C13 + 3 x IEC320 C19Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19

Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19Bank2: Outlet 17 – 24; 7 x C13 + 1 x C19

Nominal Output Voltage

100 – 240 VAC

Maximum Output Current (Outlet)

C13: 10A(Max) C19: 16A(Max)

Maximum Output Current (Bank)

16A(Max)

Maximum Output Current (Total)

32A(Max)

Breakers 2 x 16A UL489 Breaker 2 x 16A Slim Breaker

Metering Bank Level Current, Voltage, VA , PF and kWh Monitoring

Outlet Switching None

Environment Sensor Port

2

Metering Accuracy Voltage Range: 100VAC ~ 250VAC +/-1%

Power Range: 100W ~ Maximum Capacity +/- 2%Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%

Mechanical

Dimensions (H x W x D)

177.5 x 6.6 x 4.4 cm

Shipping Dimensions ( H x W x D)

189 x 21x 17 cm

Weight / Shipping Weight

6 / 10 kg 5.9 / 9.9 kg

Power Cord Length 1.6 m

Environmental

Temperature (Operating / Storage)

0–40°C / -20–60°C

Humidity (Operating , Storage)

0–80% RH, Non-Condensing

Compliance

EMC Verification CE, C-Tick, Others by Request CE, Others by Request

Safety Verification TUV-CB, GOST, Others by Request CE-LVD, Others by Request

Page 23: Aten NrGence Energy Intelligence PDU for Datacenters

17

Metered PDU (32A) PE5340sG / PE5340SLG / PE5312sGL / PE5312sGR

PE5312sGL

PE5312sGR

PE5340sG

PE5340SLG

66

79.2

44

1359.8

1359.8

79.2

4466

6644

1359.8

55

66

47 44 79.2

1359.8 mm

PE5340sG

PE5340SLG

FeaturesConnections• Built-in 10/100 Mbps Ethernet port• Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3

• 2-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS

• Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more

Metering• Bank level power metering and monitoring • Environment monitoring via external sensors for rack temperature and humidity readings and alerts

• Current, voltage, power, power dissipation, temperature and humidity metering with threshold settings

Outlet Switch Control• Always On

Special Features• Lok-U-Plug – easily secures power cable to PDU• Low profile dimension: PE5340SLG

Page 24: Aten NrGence Energy Intelligence PDU for Datacenters

Refer to page 33 for more information.

PDUs for International Regions (IEC System) 18

Specifications

Optional Accessories

Type Part No. Description PE5340sG PE5340SLG PE5312sGL PE5312sGR

Environment Sensors

EA1140 Temperature • • • •

EA1240 Temperature / Humidity • • • •

EA1340 Differential Pressure / Temperature • • • •

Door Sensors

EA1440 Photo Door Sensor

EA1441 Inductive Proximity Door Sensor

EA1442 Reed Door Sensor

Cable Holders2X-EA07 Lok-U-Plug Cable Holder (10 pcs per pack) • • • •

2X-EA08 Lok-U-Plug Installation Tool (4 pcs per pack) • • • •

Mounting Kits

2X-015G Double Mount Rail • • • •

2X-016G Slide Rail Kit

2X-017G Button Mount Kit •

2X-018G Side Panel Mount Kit • • • •

2X-019G Side Panel Double Mount Kit

Model PE5340sG PE5340SLG PE5312sGL PE5312sGR

Electrical

Nominal Input Voltage

100 – 240 VAC

Maximum Input Current

32A(Max)

Input Frequency 50-60 Hz

Input Connection IEC 60309 32A

Input Power 7360 VA(Max)

Outlet TypeTotal: 40 x IEC320 C13

Bank1: Outlet 1 – 20; 20 x C13Bank2: Outlet 21 – 40; 20 x C13

Total: 12 x UK BS1363Bank1: Outlet 1 – 6; 6 x UK BS1363

Bank2: Outlet 7 – 12; 6 x UK BS1363

Nominal Output Voltage

100 – 240 VAC

Maximum Output Current (Outlet)

C13: 10A(Max) BS1363: 13A(Max)

Maximum Output Current (Bank)

16A(Max)

Maximum Output Current (Total)

32A(Max)

Breakers 2 x 16A UL489 Breaker 2 x16A Slim Breaker 2 x16A UL489 Breaker

Metering Bank Level Current, Voltage, VA , PF and kWh Monitoring

Outlet Switching None

Environment Sensor Port

2

Metering Accuracy Voltage Range: 100VAC ~ 250VAC +/-1%

Power Range: 100W ~ Maximum Capacity +/- 2%Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%

Mechanical

Dimensions (H x W x D)

135.9 x 6.6 x 4.4 cm

Shipping Dimensions ( H x W x D)

147 x 24.8 x 19.4 cm

Weight /Shipping Weight

4.6 / 9 kg 4.5 / 8.9 kg 5.4 / 8.1 kg

Power Cord Length 1.6 m

Environmental

Temperature (Operating / Storage)

0–40°C / -20–60°C

Humidity (Operating , Storage)

0–80% RH, Non-Condensing

Compliance

EMC Verification CE, Others by Request

Safety VerificationCE-LVD,TUV-CB,

Others by RequestCE-LVD, Others by Request

Page 25: Aten NrGence Energy Intelligence PDU for Datacenters

19

Switched PDU PE6216G / PE6324G / PE6324LG

FeaturesConnections• Built-in 10/100 Mbps Ethernet port• Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3

• 2-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS

• Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more

Metering• Bank level power metering and monitoring • Environment monitoring via external sensors for rack temperature and humidity readings and alerts

• Current, voltage, power, power dissipation, temperature and humidity metering with threshold settings

Outlet Switch Control• Remote power outlet control (On/Off, Power Cycle) by individual outlet or outlet groups• Supports multiple power control methods – Wake on LAN, Safe Shutdown, and Kill the Power

• Power-on sequencing – users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the correct order

Special Features• Proactive Overload Protection (POP) automatically powers off outlets when current overloads to protect connected devices

• Lok-U-Plug – easily secures power cable to PDU • Low profile dimension: PE6324LG

PE6324LG

PE6324G

PE6216G

4466

76.4

69

1324.8 mm

66

1775

79.2

119.

2

4466

1775

44 55

PE6216G

PE6324G

Page 26: Aten NrGence Energy Intelligence PDU for Datacenters

20

Refer to page 33 for more information.

PDUs for International Regions (IEC System)

SpecificationsModel PE6216G PE6324G PE6324LG

Electrical

Nominal Input Voltage

100 – 240 VAC

Maximum Input Current

16A(Max) 32A(Max)

Input Frequency 50-60 Hz

Input Connection IEC60320 C20 IEC 60309 32A

Input Power 3680 VA(Max) 7360 VA(Max)

Outlet TypeTotal: 14 x IEC320 C13 + 2 x IEC320 C19Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19

Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19

Total: 21 x IEC320 C13 + 3 x IEC320 C19Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19

Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19Bank2: Outlet 17 – 24; 7 x C13 + 1 x C19

Nominal Output Voltage

100 – 240 VAC

Maximum Output Current (Outlet)

C13: 10A(Max) C19: 16A(Max)

Maximum Output Current (Bank)

16A(Max)

Maximum Output Current (Total)

16A(Max) 32A(Max)

Breakers 1 x 16A Non-Fuse Breaker 2 x 16A UL489 Breaker 2 x 16A Slim Breaker

Metering Bank Level Current, Voltage, VA, PF and kWh Monitoring

Outlet Switching Yes

Environment Sensor Port

2

Metering Accuracy Voltage Range: 100VAC ~ 250VAC +/-1%

Power Range: 100W ~ Maximum Capacity +/- 2%Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%

Mechanical Dimensions (H x W x D)

132.5 x 6.6 x 4.4 cm 177.5 x 6.6 x 4.4 cm

Shipping Dimensions ( H x W x D)

142 x 16 x 17 cm 189 x 21 x 17 cm

Weight /Shipping Weight

3.7 / 7.7 kg 6.3 / 10.3 kg 6.2 / 10.2 kg

Power Cord Length 3 m 1.6 m

Environmental

Temperature (Operating / Storage)

0–40˚C / -20–60˚C 0–50˚C / -20–60˚C

Humidity (Operating , Storage)

0–80% RH, Non-Condensing

Compliance

EMC Verification CE, C-Tick, Others by Request CE, Others by Request

Safety Verification TUV-CB, GOST, Others by Request TUV-CB, CE-LVD, Others by Request CE-LVD, Others by Request

Optional Accessories

Type Part No. Description PE6216G PE6324G PE6324LG

Environment Sensors

EA1140 Temperature • • •

EA1240 Temperature / Humidity • • •

EA1340 Differential Pressure / Temperature • • •

Door Sensors

EA1440 Photo Door Sensor

EA1441 Inductive Proximity Door Sensor

EA1442 Reed Door Sensor

Cable Holders2X-EA07 Lok-U-Plug Cable Holder (10 pcs per pack) • • •

2X-EA08 Lok-U-Plug Installation Tool (4 pcs per pack) • • •

Mounting Kits

2X-015G Double Mount Rail • • •

2X-016G Slide Rail Kit • •

2X-017G Button Mount Kit • •

2X-018G Side Panel Mount Kit • • •

2X-019G Side Panel Double Mount Kit • •

Page 27: Aten NrGence Energy Intelligence PDU for Datacenters

21

Outlet-Metered PDU (16A) PE7214G / PE7216G / PE7324G / PE7328G

PE7216G

PE7214G

606.9 mm

66

4466

1324.8

76.4

6944

PE7216G

FeaturesConnections• Built-in 10/100 Mbps Ethernet port• Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3

• 2-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS

• Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more

Metering• PDU and outlet level power metering and monitoring • Environment monitoring via external sensors for rack temperature and humidity readings and alerts

• Current, voltage, power, power dissipation, temperature and humidity metering with threshold settings

Outlet Switch Control• Always On

Special Features• Lok-U-Plug – easily secures power cable to PDU

PE7328G

PE7324G

6644

1775 mm

119.

279

.2

664447

1359.8

119.

279

.2

PE7324G

Page 28: Aten NrGence Energy Intelligence PDU for Datacenters

Refer to page 33 for more information.

PDUs for International Regions (IEC System) 22

Specifications

Optional Accessories

Type Part No. Description PE7214G PE7216G PE7324G PE7328G

Environment Sensors

EA1140 Temperature • • • •

EA1240 Temperature / Humidity • • • •

EA1340 Differential Pressure / Temperature • • • •

Door Sensors

EA1440 Photo Door Sensor • • • •

EA1441 Inductive Proximity Door Sensor • • • •

EA1442 Reed Door Sensor • • • •

Cable Holders2X-EA07 Lok-U-Plug Cable Holder (10 pcs per pack) • • • •

2X-EA08 Lok-U-Plug Installation Tool (4 pcs per pack) • • • •

Mounting Kits

2X-015G Double Mount Rail • • • •

2X-016G Slide Rail Kit •

2X-017G Button Mount Kit •

2X-018G Side Panel Mount Kit • • • •

2X-019G Side Panel Double Mount Kit • •

Model PE7214G PE7216G PE7324G PE7328G

Electrical

Nominal Input Voltage

100 – 240 VAC

Maximum Input Current

16A(Max) 32A(Max)

Input Frequency 50-60 Hz

Input Connection IEC60320 C20 IEC 60309 32A

Input Power 3680 VA(Max) 7360 VA(Max)

Outlet Type

Total: 12 x IEC320 C13 + 2 x IEC320 C19

Bank1: Outlet 1 – 14; 12 x C13 + 2 x C19

Total: 14 x IEC320 C13 + 2 x IEC320 C19

Bank1-1: Outlet 1 - 8; 7 x C13 + 1 x C19

Bank1-2: Outlet 9 - 16; 7 x C13 + 1 x C19

Total: 21 x IEC320 C13 + 3 x IEC320 C19

Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19

Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19

Bank2: Outlet 17 – 24; 7 x C13 + 1 x C19

Total: 24 x IEC320 C13 + 4 x IEC320 C19

Bank1: Outlet 1 – 14; 12 x C13 + 2 x C19

Bank2: Outlet 15 – 28; 12 x C13 + 2 x C19

Nominal Output Voltage

100 – 240 VAC

Maximum Output Current (Outlet)

C13: 10A(Max) C19: 16A(Max)

Maximum Output Current (Bank)

16A(Max)

Maximum Output Current (Total)

16A(Max) 32A(Max)

Breakers 1 x 16A Non-Fuse Breaker 2 x 16A UL489 Breaker

Metering Outlet Level Current, Voltage, VA, PF, kWh Monitoring

Outlet Switching None

Environment Sensor Port

4

Metering Accuracy Voltage Range: 100VAC ~ 250VAC +/-1%

Power Range: 100W ~ Maximum Capacity +/- 2%Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%

Mechanical Dimensions (H x W x D) 90.96 x 6.6 x 4.4 cm 132.5 x 6.6 x 4.4 cm 177.5 x 6.6 x 4.4 cm 135.9 x 6.6 x 4.4 cm

Shipping Dimensions ( H x W x D)

100 x 18.7 x 16.6 cm 142 x 16 x 17 cm 189 x 21 x 17 cm 142 x 16 x 17 cm

Weight / Shipping Weight

2.7 / 3.8 kg 3.7 / 7.7 kg 6.2 / 10.2 kg 4.1 / 7.9 kg

Power Cord Length 3 m 1.6 m

Environmental

Temperature (Operating / Storage)

0–40°C / -20–60°C

Humidity (Operating , Storage)

0–80% RH, Non-Condensing

Compliance

EMC Verification CE, Others by Request

Safety Verification CE-LVD, Others by Request CE-LVD, TUV-CB, Others by Request

Page 29: Aten NrGence Energy Intelligence PDU for Datacenters

23

Outlet-Metered-Switched PDU PE8216G / PE8316G / PE8324G

PE8216G

PE8316G

66

1359.8

79.2

4466

44

1324.8 mm

76.4

69

FeaturesConnections• Built-in 10/100 Mbps Ethernet port• Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3

• 2-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS

• Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more

Metering• PDU and outlet level power metering and monitoring • Environment monitoring via external sensors for rack temperature and humidity readings and alerts

• Current, voltage, power, power dissipation, temperature and humidity metering with threshold settings

Outlet Switch Control• Remote power outlet control (On/Off, Power Cycle) by individual outlet or outlet groups• Outlet groups supported at the PDU level• Supports multiple power control methods – Wake on LAN, Safe Shutdown, and Kill the Power

• Power-on sequencing – users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the correct order

Special Features• Proactive Overload Protection (POP) automatically powers off outlets when current overloads to protect connected devices

• Lok-U-Plug – easily secures power cable to PDU

PE8324G

66

1775

119.

279

.2

44

PE8324G

PE8216G

Page 30: Aten NrGence Energy Intelligence PDU for Datacenters

Refer to page 33 for more information.

PDUs for International Regions (IEC System) 24

Specifications

Optional Accessories

Type Part No. Description PE8216G PE8316G PE8324G

Environment Sensors

EA1140 Temperature • • •

EA1240 Temperature / Humidity • • •

EA1340 Differential Pressure / Temperature • • •

Door Sensors

EA1440 Photo Door Sensor • • •

EA1441 Inductive Proximity Door Sensor • • •

EA1442 Reed Door Sensor • • •

Cable Holders2X-EA07 Lok-U-Plug Cable Holder (10 pcs per pack) • • •

2X-EA08 Lok-U-Plug Installation Tool (4 pcs per pack) • • •

Mounting Kits

2X-015G Double Mount Rail • • •

2X-016G Slide Rail Kit •

2X-017G Button Mount Kit •

2X-018G Side Panel Mount Kit • • •

2X-019G Side Panel Double Mount Kit •

Model PE8216G PE8316G PE8324G

Electrical

Nominal Input Voltage

100 – 240 VAC

Maximum Input Current

16A(Max) 32A(Max)

Input Frequency 50-60 Hz

Input Connection IEC60320 C20 IEC 60309 32A

Input Power 3680 VA(Max) 7360 VA(Max)

Outlet Type

Total: 14 x IEC320 C13 + 2 x IEC320 C19

Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19

Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19

Total:6 x IEC320 C13 + 10 x IEC320 C19

Bank1:Outlet 1 – 8; 3 x C13 + 5 x C19

Bank2:Outlet 9 – 16; 3 x C13 + 5 x C19

Total: 21 x IEC320 C13 + 3 x IEC320 C19

Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19

Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19

Bank2: Outlet 17 – 24; 7 x C13 + 1 x C19

Nominal Output Voltage

100 – 240 VAC

Maximum Output Current (Outlet)

C13: 10A(Max) C19: 16A(Max)

Maximum Output Current (Bank)

16A(Max)

Maximum Output Current (Total)

16A(Max) 32A(Max)

Breakers 1 x 16A Non-Fuse Breaker 2 x 16A UL489 Breaker

Metering Outlet Level Current, Voltage, VA , PF and kWh Monitoring

Outlet Switching Yes

Environment Sensor Port

4

Metering Accuracy Voltage Range: 100VAC ~ 250VAC +/-1%

Power Range: 100W ~ Maximum Capacity +/- 2%Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%

Mechanical Dimensions (H x W x D) 132.5 x 6.6 x 4.4 cm 136 x 6.6 x 4.4 cm 177.5 x 6.6 x 4.4 cm

Shipping Dimensions ( H x W x D)

142 x 16 x 17 cm 147 x 24.8 x 19.4 cm 189 x 21 x 17 cm

Weight /Shipping Weight

3.9 / 7.9 kg 5.1 / 7.7 kg 6.5 / 10.5 kg

Power Cord Length 3 m 1.6 m

Environmental

Temperature (Operating / Storage)

0–40°C / -20–60°C

Humidity (Operating , Storage)

0–80% RH, Non-Condensing

Compliance

EMC Verification CE, Others by Request

Safety Verification TUV-CB, CE-LVD, Others by Request CE-LVD, Others by Request TUV-CB, CE-LVD, Others by Request

Page 31: Aten NrGence Energy Intelligence PDU for Datacenters

25

Outlet-Metered-Critical-Load PDU (16A) PE9216G / PE9222G / PE9324G / PE9330G

PE9222G

PE9216G

66

1324.8 mm

69 76.4

44

1324.6

66

44

PE9216G

FeaturesConnections• Built-in 10/100 Mbps Ethernet port• Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3

• 2-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS

• Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more

Metering• PDU and outlet level power metering and monitoring • Environment monitoring via external sensors for rack temperature and humidity readings and alerts

• Current, voltage, power, power dissipation, temperature and humidity metering with threshold settings

Outlet Switch Control• Remote power outlet control (On/Off, Power Cycle) by individual outlet or outlet groups• Outlet groups supported at the PDU level• Supports multiple power control methods – Wake on LAN, Safe Shutdown, and Kill the Power

• Power-on sequencing – users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the correct order

• Critical load outlet – keeps power always on for critical load devices

Special Features• Proactive Overload Protection (POP) automatically powers off outlets when current overloads to protect connected devices

• Lok-U-Plug – easily secures power cable to PDU

PE9330G

PE9324G 1775

66

119.

279

.2

4466

1775

79.2

119.

2

44

PE9324G

Page 32: Aten NrGence Energy Intelligence PDU for Datacenters

PDU for International Region (IEC System) 26

Type Part No. Description PE9216G PE9222G PE9324G PE9330G

Environment Sensors

EA1140 Temperature • • • •

EA1240 Temperature / Humidity • • • •

EA1340 Differential Pressure / Temperature • • • •

Door Sensors

EA1440 Photo Door Sensor • • • •

EA1441 Inductive Proximity Door Sensor • • • •

EA1442 Reed Door Sensor • • • •

Cable Holders2X-EA07 Lok-U-Plug Cable Holder (10 pcs per pack) • • • •

2X-EA08 Lok-U-Plug Installation Tool (4 pcs per pack) • • • •

Mounting Kits

2X-015G Double Mount Rail • • • •

2X-016G Slide Rail Kit • •

2X-017G Button Mount Kit • •

2X-018G Side Panel Mount Kit • • • •

2X-019G Side Panel Double Mount Kit • •

Model PE9216G PE9222G PE9324G PE9330G

Electrical

Nominal Input Voltage 100 – 240 VAC

Maximum Input Current

16A(Max) 32A(Max)

Input Frequency 50-60 Hz

Input Connection IEC60320 C20 IEC 60309 32A

Input Power 3680 VA(Max) 7360 VA(Max)

Outlet Type

Total: 14 x IEC320 C13 + 2 x IEC320 C19

Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19

Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19

Total: 19 x IEC320 C13 + 3 x IEC320 C19

Bank1-1: Outlet 1 – 14; 12 x C13 + 2 x C19

Bank1-2: Outlet 15 – 22; 7 x C13 + 1 x C19

Total: 21 x IEC320 C13 + 3 x IEC320 C19

Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19

Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19

Bank2: Outlet 17 – 24; 7 x C13 + 1 x C19

Total: 26 x IEC320 C13 + 4 x IEC320 C19

Bank1-1: Outlet 1 – 14; 12 x C13 + 2 x C19

Bank1-2: Outlet 15 – 22; 7 x C13 + 1 x C19

Bank2: Outlet 23 – 30; 7 x C13 + 1 x C19

Nominal Output Voltage

100 – 240 VAC

Maximum Output Current (Outlet)

C13: 10A(Max) C19: 16A(Max)

Maximum OutputCurrent (Bank)

16A(Max)

Maximum Output Current (Total)

16A(Max) 32A(Max)

Breakers 1 x 16A Non-Fuse Breaker 2 x 16A UL489 Breaker

Metering Outlet Level Current, Voltage, VA, PF, kWh Monitoring

Outlet Switching Bank1-1: None; Bank1-2: Yes Bank1-1: None; Bank1-2: Yes; Bank2: Yes

Environment Sensor Port

4

Metering Accuracy Voltage Range: 100VAC ~ 250VAC +/-1%

Power Range: 100W ~ Maximum Capacity +/- 2%Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%

Mechanical Dimensions (H x W x D) 132.5 x 6.6 x 4.4 cm 177.5 x 6.6 x 4.4 cm

Shipping Dimensions ( H x W x D)

142 x 16 x 17 cm 143 x 20.6 x 19.4 cm 189 x 21 x 17 cm

Weight / Shipping Weight

3.8 / 7.8 kg 3.9 / 7.9 kg 6.4 / 10.4 kg 6.6 / 10.6 kg

Power Cord Length 3 m 1.6 m

Environmental

Temperature (Operating / Storage)

0–40°C / -20–60°C

Humidity (Operating , Storage)

0–80% RH, Non-Condensing

Compliance

EMC Verification CE, Others by Request

Safety VerificationTUV-CB, CE-LVD, Others by Request

CE-LVD, Others by RequestTUV-CB, CE-LVD, Others by Request

Specifications

Refer to page 33 for more information.Optional Accessories

Page 33: Aten NrGence Energy Intelligence PDU for Datacenters

27

Energy Monitoring Device EC1000 / EC2004

FeaturesOperation

• Space saving 1U rack mounting with front and rear mounting• 4 RJ-45 Energy Sensor Ports to monitor four Energy PDU currents (0A to 32A per port, 2 Current Energy Sensors Ports, 2 Current / Voltage Energy Sensors Ports for EC2004)• 4 RJ-45 Energy Sensor Ports to monitor four Energy PDU currents for EC1000 (0A to 32A per port)• 4 RJ-11 Environment Sensor Ports to monitor temperature, humidity, and differential pressure*• 4-pin dry contact Rack Door Sensor status monitor (EC2004)• Maximum Amperage Monitor 32A@100V~240V (Energy Box)• 3 digit 7 segment front panel LED displays current/sensor/IP address information• Threshold monitoring for: - Current, Voltage - Temperature* - Humidity* - Differential pressure*• Threshold alerting through: - Local: audible alarm and LED lights - Remote: SMTP/SNMP trap/Syslog

Management

• Front panel LED indicators for current, temperature*, humidity*, differential pressure*, and IP address information at the Energy Box• Remote real-time current/voltage, temperature*, humidity*, and differential pressure* monitoring and management• Management through eco Sensors Energy Management Software or 3r party SNMP manager• Supports name assignment for individual Energy PDUs• Event Logging – 128 line event log• Syslog support• F/W upgradable

Remote Access

• Remote management via TCP/IP using built in 10/100Mbps Ethernet port• Management via built in browser based GUI• Network Interfaces: TCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, 10Base-T/100Base-TX, auto sense, Ping• Supports SNMP Manager V1, V2, V3

Security

• Strong security features include password protection and advanced encryption technologies – utilizing 128 bit SSL• RADIUS authorization and authentication

* Requires external sensors

EC1000

EC2004

Page 34: Aten NrGence Energy Intelligence PDU for Datacenters

Refer to page 33 for more information.

Energy Monitoring Device 28

SpecificationsFunction EC1000 EC2004

Connectors

Power 1 x DC Jack

Current Monitor 4 x RJ-45 2 x RJ-45

Voltage / Current Monitor N/A 2 x RJ-45

Env. Sensor 4 x RJ-11

Door Sensor N/A 4 Pin Dry Contact

LAN 1 x RJ-45 Female with LEDs (Silver/LED Orange/Green)

LEDs

Monitored PDU Status 4 (Orange)

Port Numbers 1 digit 7-segment (Orange)

Energy / Env. / IP Selection 3 (Green)

Current /Sensor / Voltage/ IP Address 3 digit 7-segment (Orange)

Power 1 (Blue)

Door Sensor 1 (Red)

LAN10M / 100 Mbps 1 (Orange/Green)

Link 1 (Green)

Env. Sensor Status 4 (Green)

SwitchesReset 1 x Semi-recessed Pushbutton

Selection 1 x Selection Button, 1 x Up, 1 x Down

Monitoring Range

100–240V~; 50/60Hz; 0A to 32A,LED Display Resolution 0.1A

Voltage Range: 100VAC ~ 250VAC +/-1%Power Range: 100W ~ Maximum Capacity +/- 2%Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%

Operating Temperature

0–50°C

Storage Temperature -20–60°C

Operating / Storage Humidity

0–80% RH, Non-Condensing

Housing Metal

Weight 0.64 kg

Size ( W × D x H ) 20.00 x 7.59 x 4.20 cm

Optional Accessories

Type Part No. Description EC1000 EC2004

Environment Sensors

EA1140 Temperature • •

EA1240 Temperature / Humidity • •

EA1340 Differential Pressure / Temperature • •

Door Sensors

EA1440 Photo Door Sensor •

EA1441 Inductive Proximity Door Sensor •

EA1442 Reed Door Sensor •

Cable Holders2X-EA07 Lok-U-Plug Cable Holder (10 pcs per pack)

2X-EA08 Lok-U-Plug Installation Tool (4 pcs per pack)

Mounting Kits

2X-015G Double Mount Rail

2X-016G Slide Rail Kit

2X-017G Button Mount Kit

2X-018G Side Panel Mount Kit

2X-019G Side Panel Double Mount Kit

Page 35: Aten NrGence Energy Intelligence PDU for Datacenters

eco Sensors - A Comprehensive Solution for Data Center Optimization

What is eco Sensors software?eco Sensors software gives you the tools to create a fully optimized, energy e�cient data center. The software combines ATEN’s cutting edge eco-technology with an intuitive GUI to deliver the best Data Center Infrastruc-ture Management (DCIM) software on the market. ATEN’s eco Sensors software not only gives you the means to assess, diagnose and estimate your energy saving potential, it provides advice on the best way to do it.

OverviewATEN’s eco Sensors perfectly synergize with NRGence™ Energy Intelligence PDUs to provide the mecha-nisms you need to optimize your data center energy needs. The software and PDU can measure the Dynamic Rack Cooling Index (RCI) and Return Temperature Index (RTI). This allows data center administrators to analyze the operational e�ciency of equipment versus the cost of cooling, in order to better manage power allocation. These indexes have been incorporated into the U.S. Department of Energy DC Pro software tools for data center energy assessments and the Data Center Energy Practitioner program.

Using ATEN’s NRGence™ Energy Intelligence PDU and eco Sensors energy & DCIM management software, an administrator’s data center is equipped with real time monitoring, measurements and EnPIs analysis, that produce reports of power usage, PUE, RCI and RTI to meet the ISO 50001 requirements. With these critical indexes, you can generate customized reports about your data center’s status that include energy saving suggestions. Following these suggestions allows you to optimize energy usage to save energy without harming your IT equipment’s reliability.

ATEN’s eco Sensors software is available in a Master and Client version. The Master version o�ers the full functionalities of the eco Sensors software, and is capable of managing the PDU through SNMP and managing the client node through TCP/IP. This allows multiple users to log in to the master node concurrently to manage PDUs in di�erent authorized zones, making distributed PDU management much more e�cient under one centralized environment. With the Client version, users are allowed to log in to a master node to monitor PDU status and control each outlet on the PDUs. Having a Master and Client version allows data centers to optimize their performance and centralize their management.

Power Measurement and Scheduling By Zone – eco Sensors allows you to group racks in your data center in up to 128 zones, or de�ne areas that you wish to get readings for. Administrators can schedule power on & o� by zone or monitor the real-time stats such as peak and average power usage per zone.

Power Analysis Report – eco Sensors o�ers comprehensive power analysis reports which can be separated by departments and locations. It displays trend charts in real-time or according to the day, month, year, or grasp the power consumption needs for each of the four seasons. By knowing actual power consumption trends, you can allocate power resources without waste and prevent wasted power capacity.

Optimum Data Center Energy Management – When used in conjunction with Sensor-enabled eco PDUs, eco Sensors Energy Management Software provides administrators with a real time Rack Cooling Index ® and dynamic power analysis to protect IT equipment from excess heat or insu�cient power capacity.

Fan Energy Saving & Chiller Energy Saving – eco Sensors software provides real-time power measurements and environment monitoring information of your data center in a variety of formats, such as zone, rack, device or outlet level. By generating customized reports about your data center’s status, administrators can evaluate the potential Fan Energy Saving & Chiller Energy Saving percentage. Furthermore, administrators can also realize how long it will take to recover the invested resources, con�rming the investment returns.

Energy Saving Estimates Zone Setting

DCie RCI-HIStrategic Operational Dashboard The Bene�ts of Using eco Sensors

Real-time Rack Status Monitoring

Temperature Sensor

eco PDU Sensor Probes Server Storage

Normal

1

1

2 3 4 5

1 5 10 15 20 25

5

A

6 7 8 9

10

Warning CriticalUnreachable

IT O�ce

Internet/LAN

Internet/LAN

IT O�ce

Report Title: Sales Department IT Power AnalysisDaily Report: 2011/1/1 – 2011/5/5 by Bill Li

IT Power Usage Chart

1/1 2/2 3/3 4/4 5/5 1/1 2/2 3/3 4/4 5/5

kWH

6

- Sales 2

- Sales 3

- Sales 1

4

2

IT Power Load Chart

kWH

6

Sales4

2

IT Inventory List in Report

No. Name Peak Watts Peak CO2e/Hrs Yearly Power Cost Yearly CO2e Cost Location

01 Web Server 3 1.8 kg 1200 600 L25

02 Log Server 6 3.6 kg 3600 1800 L27

Di�erential Pressure Sensor

eco Sensors Master & Client Version

eco SensorsClient Version

eco SensorsClient Version

eco SensorsClient Version

IP Network IP NetworkMySQL

Master Version O�ers full functionalities of eco Sensors Manage clients through TCP/IP Manage PDUs through SNMP

Client Version Users are allowed to log in to the Master version Real time functions: Dashboard / Power Control / Group Control

eco SensorsMaster Version

29

Page 36: Aten NrGence Energy Intelligence PDU for Datacenters

eco Sensors - A Comprehensive Solution for Data Center Optimization

What is eco Sensors software?eco Sensors software gives you the tools to create a fully optimized, energy e�cient data center. The software combines ATEN’s cutting edge eco-technology with an intuitive GUI to deliver the best Data Center Infrastruc-ture Management (DCIM) software on the market. ATEN’s eco Sensors software not only gives you the means to assess, diagnose and estimate your energy saving potential, it provides advice on the best way to do it.

OverviewATEN’s eco Sensors perfectly synergize with NRGence™ Energy Intelligence PDUs to provide the mecha-nisms you need to optimize your data center energy needs. The software and PDU can measure the Dynamic Rack Cooling Index (RCI) and Return Temperature Index (RTI). This allows data center administrators to analyze the operational e�ciency of equipment versus the cost of cooling, in order to better manage power allocation. These indexes have been incorporated into the U.S. Department of Energy DC Pro software tools for data center energy assessments and the Data Center Energy Practitioner program.

Using ATEN’s NRGence™ Energy Intelligence PDU and eco Sensors energy & DCIM management software, an administrator’s data center is equipped with real time monitoring, measurements and EnPIs analysis, that produce reports of power usage, PUE, RCI and RTI to meet the ISO 50001 requirements. With these critical indexes, you can generate customized reports about your data center’s status that include energy saving suggestions. Following these suggestions allows you to optimize energy usage to save energy without harming your IT equipment’s reliability.

ATEN’s eco Sensors software is available in a Master and Client version. The Master version o�ers the full functionalities of the eco Sensors software, and is capable of managing the PDU through SNMP and managing the client node through TCP/IP. This allows multiple users to log in to the master node concurrently to manage PDUs in di�erent authorized zones, making distributed PDU management much more e�cient under one centralized environment. With the Client version, users are allowed to log in to a master node to monitor PDU status and control each outlet on the PDUs. Having a Master and Client version allows data centers to optimize their performance and centralize their management.

Power Measurement and Scheduling By Zone – eco Sensors allows you to group racks in your data center in up to 128 zones, or de�ne areas that you wish to get readings for. Administrators can schedule power on & o� by zone or monitor the real-time stats such as peak and average power usage per zone.

Power Analysis Report – eco Sensors o�ers comprehensive power analysis reports which can be separated by departments and locations. It displays trend charts in real-time or according to the day, month, year, or grasp the power consumption needs for each of the four seasons. By knowing actual power consumption trends, you can allocate power resources without waste and prevent wasted power capacity.

Optimum Data Center Energy Management – When used in conjunction with Sensor-enabled eco PDUs, eco Sensors Energy Management Software provides administrators with a real time Rack Cooling Index ® and dynamic power analysis to protect IT equipment from excess heat or insu�cient power capacity.

Fan Energy Saving & Chiller Energy Saving – eco Sensors software provides real-time power measurements and environment monitoring information of your data center in a variety of formats, such as zone, rack, device or outlet level. By generating customized reports about your data center’s status, administrators can evaluate the potential Fan Energy Saving & Chiller Energy Saving percentage. Furthermore, administrators can also realize how long it will take to recover the invested resources, con�rming the investment returns.

Energy Saving Estimates Zone Setting

DCie RCI-HIStrategic Operational Dashboard The Bene�ts of Using eco Sensors

Real-time Rack Status Monitoring

Temperature Sensor

eco PDU Sensor Probes Server Storage

Normal

1

1

2 3 4 5

1 5 10 15 20 25

5

A

6 7 8 9

10

Warning CriticalUnreachable

IT O�ce

Internet/LAN

Internet/LAN

IT O�ce

Report Title: Sales Department IT Power AnalysisDaily Report: 2011/1/1 – 2011/5/5 by Bill Li

IT Power Usage Chart

1/1 2/2 3/3 4/4 5/5 1/1 2/2 3/3 4/4 5/5

kWH

6

- Sales 2

- Sales 3

- Sales 1

4

2

IT Power Load Chart

kWH

6

Sales4

2

IT Inventory List in Report

No. Name Peak Watts Peak CO2e/Hrs Yearly Power Cost Yearly CO2e Cost Location

01 Web Server 3 1.8 kg 1200 600 L25

02 Log Server 6 3.6 kg 3600 1800 L27

Di�erential Pressure Sensor

eco Sensors Master & Client Version

eco SensorsClient Version

eco SensorsClient Version

eco SensorsClient Version

IP Network IP NetworkMySQL

Master Version O�ers full functionalities of eco Sensors Manage clients through TCP/IP Manage PDUs through SNMP

Client Version Users are allowed to log in to the Master version Real time functions: Dashboard / Power Control / Group Control

eco SensorsMaster Version

30

Page 37: Aten NrGence Energy Intelligence PDU for Datacenters

Metered Ready PDU PE1216G / PE1324G/ PE1213G/ PE1316G

31

Energy & DCIM Management Software eco Sensors

Features• Automatic discovery of all PE devices within the same intranet

• Remote real-time power measurement and monitoring

-PDU level current / voltage / power dissipation / power consumption

-Outlet ON / OFF / Recycle status

• Second window to monitor data center status including PUE, RTI, RCI, Power, Carbon Footprint and rack status

• Remote real-time power outlet management*

-Power outlet ON / OFF / Cycle switching by outlet or user-defined group

-Power outlet ON / OFF / Cycle switching with pre-defined schedule

-User-defined outlet level delays for sequential power up

-Current / Voltage / Power Dissipation / Power Consumption threshold level setting

-User access assignment for every outlet

-Name assignment to individual outlets

• Remote real-time environment sensor monitoring

-Temperature / Temperature + Humidity reading / Temperature + Differential Pressure

-Temperature and Humidity threshold level setting

• Plotting/Monitoring of all PE devices

-Add data center server racks

-Add PE devices for each server rack

-Manage device/device outlet status for each plot

• Offers essential data center indices including Rack Intake Temperature, Rack Exhaust Temperature, Rack Equipment

Temperature Difference, RCI ( Rack Cooling Index ), RTI ( Return Temperature Index ), RHI ( Rack Humidity Index ), RPI (

Rack Pressure Index ), RAI ( Rack Airflow Index )

• Power analysis report for optimiz nter energy management – including power usage, power load, power cost, CO2 cost,

power capacity and trend

• Exceed threshold alert through SMTP and System log

• 10240 line event log

• System log provision

• Two-level password security

• Strong security features include password protection and advanced encryption technologies – 128 bit SSL

*Not all functions are supported by all eco PDU PE models. Please see www.aten.com for more details.

Overall Rack Cooling Effectiveness Power Control

Temperature Sensor Number

Page 38: Aten NrGence Energy Intelligence PDU for Datacenters

32Energy & DCIM Management Software

Functions

Master Version Client Version

Energy

Dash BoardReal time monitor power usage information, temperature and humidity

• •

Power Control Monitor PDU status and control power outlet • •

Group Control Control power outlet by group • •

Power Analysis Power Usage Analysis by hour, day, month or quarter •

Thermal Analysis Thermal Analysis by hour, day, month or quarter •

User Account Account Management, access right by function, device and group •

Device

Zone Define Define data center zone •

Rack Install Install server rack in data center •

Device Setup Setup PDU or Energy Box in data center •

Define Data GroupDefine data group for report analysis, group control and schedule control

In-Synergy Gateway Support external gateway for CT meter •

System

Sys Settings System parameters, SNMP and SMTP Settings •

Maintenance PDU and energy box firmware upgrade •

DatabaseDatabase settings, capacity management, import/export, config backup/restore

Task Scheduling group outlet control and config backup •

Billing Electricity billing report •

Log

System Log View system log •

Log Options Log Settings •

Events Event Settings •

Hardware Requirements

Master Version Client Version

Operating System Windows 7/Windows Server 2003 and later Windows 7/Windows Server 2003 and later

CPU 2.5 GHz Quad Core 2.0 GHz Dual Core

Display Larger than 1024x768 Larger than 1024x768

Memory 4GB 2GB

Disk 500GB 100GB

Network 10/100 Mbps Ethernet 10/100 Mbps Ethernet

System Parameter

Master Version

Max Account Number 128

Concurrent Login 8

Max PDU Number 2500

Data Center Layout 45x30 72x48 90x60

Max Rack Number 2500

Max Zone Number 128

Power Report Data At least 3 years

Real Time Dashboard Data 300GB

Page 39: Aten NrGence Energy Intelligence PDU for Datacenters

Metered Ready PDU PE1216G / PE1324G/ PE1213G/ PE1316G

33

Optional Accessories

Type Part No. Description Images Installation

Environment Sensors

EA1140 Temperature

EA1240 Temperature / Humidity

EA1340Differential Pressure /

Temperature

Door Sensors

EA1440 Photo Door Sensor

InsideRack Door

EA1441 Inductive Proximity Door Sensor

EA1442 Reed Door Sensor Door

RackFrame

Cable Holders

2X-EA07Lok-U-Plug Cable Holder

(10 pcs per pack)

2X-EA08Lok-U-Plug Installation Tool

(4 pcs per pack)

Page 40: Aten NrGence Energy Intelligence PDU for Datacenters

34Optional Accessories

Optional Accessories

Type Part No. Description Images Installation

Mounting Kits

2X-015G Double Mount Rail

2X-016G Slide Rail Kit

2X-017G Button Mount Kit

2X-018G Side Panel Mount Kit

2X-019G Side Panel Double Mount Kit

Page 41: Aten NrGence Energy Intelligence PDU for Datacenters

Belgian Subsidiary

ATEN Infotech N.V. Mijnwerkerslaan 34, 3550 Heusden-Zolder, Belgiumahttp://www.aten.eu E-mail: [email protected]

Corporate Headquarters

ATEN International Co., Ltd. 3F., No.125, Sec. 2, Datong Rd., Sijhih District., New Taipei City 221, TaiwanPhone: +886-2-8692-6789 Fax: +886-2-8692-6767 http://www.aten.com E-mail: [email protected]

Page 42: Aten NrGence Energy Intelligence PDU for Datacenters

ATEN NRGence™ Energy Intelligence PDU for Data CentersProduct Catalog

20152016Printed 03/2015 V1.1

© Copyright 2015 ATEN® International Co., Ltd.ATEN and the ATEN logo are trademarks of ATEN International Co., Ltd. All rights reserved. All other trademarks are the property of their respective owners.

Belgian Subsidiary

ATEN Infotech N.V. Mijnwerkerslaan 34, 3550 Heusden-Zolder, BelgiumPhone: +32-11-531543 Fax: +32-11-531544http://www.aten.eu E-mail: [email protected]

Corporate Headquarters

ATEN International Co., Ltd. 3F., No.125, Sec. 2, Datong Rd., Sijhih District., New Taipei City 221, TaiwanPhone: +886-2-8692-6789 Fax: +886-2-8692-6767 http://www.aten.com E-mail: [email protected]