1 AT9000 Advanced Transmitter SuperAce JTG Series Gauge Pressure Transmitter JTG9S/W Model Overview e AT9000 Advanced Transmitter is a smart transmitter which features a built-in microprocessor and outstanding stability. It is capable of measuring the flow rate, pressure, liquid level, etc. of gases, liquids, and vapors, outputting a 4 to 20 mA DC analog signal corresponding to the measured pressure. Features (1) Outstanding long-term stability • Achieves an extremely high level of stability: zero point driſt of ±0.1 % in 10 years. (2) Fast response • Response speed: 100 ms or less. Can be utilized in applications that require fast response, such as in those related to turbines. (3) Outstanding usability • Zero adjustment can be performed without removing the cover. (4) A wide variety of functions • Using a communicator, historical information regarding excessive pressure, abnormal temperature, etc., can be checked. Product Usage Precautions • is product is intended for the general industrial market. • is product is not subject to the regulations pursuant to the Chinese electronic information product pollution control laws. However, if the product is used with semiconductor manufacturing equipment, special- purpose equipment for electronic devices, etc., it may in some cases be necessary to include documents and to mark the product in accordance the Chinese electronic information product pollution control laws. If necessary, please indicate this in advance to our sales department. No. SS2-ATSG10-0100 1st edition

Transcript of AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

Page 1: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

1

AT9000 Advanced Transmitter SuperAceJTG Series Gauge Pressure Transmitter

JTG9S/W Model

OverviewThe AT9000 Advanced Transmitter is a smart transmitter which features a built-in microprocessor and outstanding stability. It is capable of measuring the flow rate, pressure, liquid level, etc. of gases, liquids, and vapors, outputting a 4 to 20 mA DC analog signal corresponding to the measured pressure.

Features(1) Outstanding long-term stability•Achievesanextremelyhighlevelofstability:zeropoint

drift of ±0.1 % in 10 years.

(2) Fast response•Responsespeed:100msorless.Canbeutilizedin

applications that require fast response, such as in those related to turbines.

(3) Outstanding usability•Zeroadjustmentcanbeperformedwithoutremovingthe

cover.

(4) A wide variety of functions•Usingacommunicator,historicalinformationregardingexcessivepressure,abnormaltemperature,etc.,canbechecked.

Product Usage Precautions•Thisproductisintendedforthegeneralindustrialmarket.

•Thisproductisnotsubjecttotheregulationspursuantto the Chinese electronic information product pollution control laws. However, if the product is used with semiconductor manufacturing equipment, special-purpose equipment for electronic devices, etc., it may in some cases be necessary to include documents and to mark the product in accordance the Chinese electronic information product pollution control laws. If necessary, please indicate this in advance to our sales department.

No. SS2-ATSG10-0100

1st edition

Page 2: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

No. SS2-ATSG10-0100Azbil Corporation

2

SpecificationsMeasuring span/setting range/working pressure range:See Table 1.

Output signal:Analogoutput:4to20mADC

Communications: SFN,HART® HART®Version:5

Supply voltage/load resistance:DC12.5to45VDCFor communication with a communicator, load resistance of atleast250Ωisrequiredbetweenloops.Regardingsupplyvoltage and load resistance, see Figure 1.

Sealed liquid:Siliconeoil(regulartype),fluorineoil(foroxygenorchlorineuse)

Waterproof/dustproofstructure:IP66/IP67

Ambienttemperaturerange:• Normaloperatingrange: Forgeneral-purposeuse:-40to+85°C Forgeneral-purposeuse(withindicators):-25to+80°C Foroxygenorchlorineuse:-10to+75°C

• Operativelimitrange: Forgeneral-purposeuse:-50to+93°C Forgeneral-purposeuse(withindicators):-30to+85°C Foroxygenorchlorineuse:-40to+80°C Foroxygenorchlorineuse (withindicators):-30to+85°C

• TIISspecialexplosion-proofmodel: -20to+60°C(withoutindicators) -20to+55°C(withindicators)

Wettedparttemperaturerange:• Normaloperatingrange: Forgeneral-purposeuse:-40to+110°C Foroxygenorchlorineuse:-20to+75°C

• Operativelimitrange: Forgeneral-purposeuse:-50to+115°C Foroxygenorchlorineuse:-40to+80°C

• TIISspecialexplosion-proofmodel: -20to+60°C(withoutindicators) -20to+55°C(withindicators)

Transportandstoragetemperaturerange:Withoutindicators:-50to+85°CWithindicators:-25to+80°CMeter body cover PVC:-10to+60°C

Ambienthumiditylimits:5to100%RH

Supplyvoltage/voltagecharacteristics:±0.005%FS/VEMC regulation compliance:EN61326-1:2013

IEC61326-2-3Lightning protection characteristics (surge immunity test, IEC61000-4-5) Line-to-line(S+,S-):±1kV Line-to-ground(S+,S-):±2kV Waveform:1.2/50(8/20)µs

Response time: 100msorless(ambienttemperature23±2°C)

Long-termstability(zeropoint):±0.1 %/10 years (JTG940 Model)±0.2%/10years(JTG960/980 Model) Drift under standard operating conditions (23±2°C,atmosphericpressure)Damping time constant:Settable to 10 levels in range 0 to 32 s(HART®communicationprotocolcanbesetinrange0to128s)

Output saturation point: Highlimit:21.6mA Lowlimit:3.6mA

Vibrationcharacteristics: Amplitude:1.5mm/frequency:5to9Hz Acceleration:4.9m/s2(0.5G)/9to200Hz

Shockcharacteristics:Acceleration9.8m/s2 (1 G)

Process pipe connection: Rc1/2internalthread,Rc1/4internal thread,1/2NPTinternalthread, 1/4NPTinternalthread

Electrical conduit connection: G1/2internalthread,1/2NPT internal thread, M20 internal thread

Body material Mainunit:SUS316 Transmittercase:aluminumalloy

Process wetted material: Meter body cover: SCS14A(SUS316equivalent)or

SUSF316,PVC Adapterflange(optional):SCS14A(SUS316equivalent),

PVC Wettedpartofmainunit:SUS316(diaphragm-only

SUS316L),alloyC-276, tantalum,SUS316L

Ventsandplugs:SUS316,PVC Gasketsforwettedpart:FEP

Table 1. Measuring Span/Setting Range/Working Pressure Range (for negative pressure in the working pressure range, see Figures 2 and 3) / overload resistance value

Model No. Measuring Span Setting Range Working Pressure Range Overload Resistant ValueJTG940 35to3500kPa -100to+3500kPa 2.0to3500kPa(Note1) 5250kPaJTG960 0.7to14MPa -0.1to+14MPa 2.0to14MPa(Note2) 21MPaJTG980 0.7to42MPa -0.1to+42MPa 2.0to42MPa(Note3) 63MPa

Notes1: IfmeterbodycovermaterialisPVC(polyvinylchloride),maximumworkingpressureisthesmallerof1.5MPaabsand the working pressure range.

2: IfboltandnutmaterialisSUS304,maximumworkingpressureis10MPa. 3: IfboltandnutmaterialisSUS304,maximumworkingpressureis20MPa.

Page 3: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

No. SS2-ATSG10-0100Azbil Corporation

3

Load

Res

istan

ce R

(Ω)

Supply Voltage E (V DC)

E - 12.5

0.0219R=

1345

1482

245

0 17.9 42 4512.5

Operative Limit Range

Normal Operating Range

Note:For communication with the communicator, load resistance of at least 250 Ω is required.

-50 -40 40 50 60 70 80 90 100 115

1.3

2.0

5.7

9.6

16

78

101.3

133.3

Wor

king

Pre

ssur

e P

(kPa

abs

.)

3.4

27

46

Operative Limit Range

Normal Operating Range

Unusable Range

Temperature (°C) 110

-10 40 75-40

54

101.3

Operative Limit Range

Liquid Temperature (°C)0 80

133.3

Normal Operating Range

Wor

king

Pre

ssur

e P

(kPa

abs

.)

Unusable Range

93

Operative Limit Range

Figure 1. Supply Voltage and Load Resistance Characteristics

Figure 2. Wetted Parts Working Pressure and Temperature (General Purpose)

Figure 3. Wetted Parts Working Pressure and Temperature (for Oxygen/Chlorine)

Boltandnutmaterial(formeterbodyfastening):Carbonsteel(SNB7),SUS304,SUS630

Finish: Standard:Bakedacrylicresincoatingfinish Corrosion-prooffinish:Urethanebakedfinish Standardcolor:Casecover:AzbilBold2.5R2.25/5,

silverN-8.2 Case:SilverN-8.2

Built-inindicators:Digital LCD indicators (optional)Engineering unit scale display compatibleCanbesettoavalueintherange-19999to+19999(4.5digits).Specify the following when issuing engineering unit scale commands.•Metercalibrationrange•Engineeringunitscale•ProportionalorsquarerootdisplayAll data setting operations are performed from the communicator.

Failure mode: The following can be selectedUpscale:21.6mA(110%)orhigherDownscale:3.6mA(-2.5%)orlower

Grounding: Dclass(resistance:lowerthan100ohms)

Installation:Mountonhorizontalonvertical2-inchdia.pipe (direct attachment to process pipe also possible)

Mass: Approx.3.7kg(JTG940/960S) Approx.6.3kg(JTG980S) For JTG9W,+1.0kg

Page 4: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

No. SS2-ATSG10-0100Azbil Corporation

4

Explosion-proof StructureTIISspecialexplosion-proofmodel(ExdIICT4)Note:Usecableswiththemaximumallowabletemperatureshownbelow.JTG9xxS:65°C(withindicators)

70°C(withoutindicators)JTG9xxW:60°C(withindicators)

65°C(withoutindicators)

OptionsExternalzeroadjustmentfunction:On-sitezeroadjustmentofthetransmittercanbeperformedusing the included magnetic bar.Note:Besuretousethisinconjunctionwiththeindicators.

Long vent drain:Maintenance, process conditions, and safety are addressed byusingadrainwhoselength(60mm)islongerthanthestandardlength(27mm).

Elbow:An adapter for changing the orientation of the electrical conduitconnectionportfromhorizontaltoverticalinordertofittheon-sitewiringconditions.Eitheroneortwocanbeselected as necessary.

High-grademoisture-free(includingoil-freefinish):Shipped with water content and oil content removed from the wetted part. (A small amount of fluorine oil is applied to vent/drain plugs in order to prevent sticking.)

Moisture-freefinish(incl.oil-freefinish):Shipped with water content and oil content removed from the wetted part (including the vent/drain plugs).

Oil-freefinish:Shipped with oil content removed from the wetted part. (A small amount of fluorine oil is applied to vent/drain plugs in order to prevent sticking.)

Highperformancetype:Has improved accuracy and ambient temperature performance.

Electricpowerspecification:Applicable in cases in which particularly strict quality control is required, as in the electric power and gas industries.Stabilitytestsunderhighstaticpressure,confirmationtestsof differential pressure gauge input-output characteristics under high-speed static pressure variation, and the like are performed.

Specialfailuremode(3.2mA):failure mode output values (low limit) during abnormal conditionswillbe3.2mA(-5%)orlower.

Variableoutputsaturationpoint:canbesetwithinthefollowingrange:12mA(50%)≤outputhighlimit≤21.6mA(110%)3.6mA(-2.5%)≤outputlowlimit<12mA(50%)Notes:RegardingtheHART®communicationprotocol

1.OptionJ8:When"Specialfailuremode3.2mA"isselected,3.2mA(-5%)≤outputlowerlimit <12mA(50%).

2.OptionJ8:When"Specialfailuremode3.2mA"isnotselected,3.8mA(-1.25%)≤outputlowerlimit <12mA(50%).

Testreport:Shows the results of having tested the appearance, input-output characteristics, insulation resistance, dielectric strength, etc., of the transmitter.

Millsheet:Shows data related to the chemical composition, heat treatment condition, and mechanical properties of the wetted part material.

Strengthcalculationsheet:Shows the results of having calculated the strength of the meter body cover, flanges, and bolts.

Withstandpressureandairtighttest(general-purposeuse):Shows the results of the wetted part withstand pressure test(waterpressure:10minutes)andairtighttest (N2:10minutes).

Testreport(withtraceabilitycertificate):Comprisedofthreedocuments:atraceabilitydiagram, acalibrationcertificate,andatestreport.

Page 5: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

No. SS2-ATSG10-0100Azbil Corporation

5

Product Usage PrecautionsBear in mind the following points when using the product in order to take full advantage of its capabilities. Also be sure to read the operating instructions for the product before use.

Installation Precautions

Warning

•Wheninstallingtheproduct,makesurethatthegasketsdo not stick out at the connections with the process (connections between adapter flanges and connecting pipes and flanges). There is a danger that the measured fluid will leak out and cause scalding and other harmful health effects. If the measured fluid is harmful to the human body, take safety measures such as wearing goggles or a mask so that it does not contact the skin or the eyes, become inhaled, etc.

•Use thisproductwithin the limitsof thedescribedusageconditions (explosionproofing,pressure rating,temperature, humidity, voltage, vibration, shock, installation orientation, ambient atmosphere, and the like). There is a danger of scalding and other harmful healtheffectsasaresultofinstrumentfailure,fire,etc.

•Whenworkinginahazardousarea,performinstallationand deployment according to the construction methods prescribedbythehazardguidelines.

In addition, with the TIIS flameproof model, for flameproof packing cable wiring system, be sure to use flameproofcableglandscertifiedbythiscompany.

Caution

•Afterinstallingthisproduct,donotuseitasascaffold,place your body weight on it, etc. Doing so may cause damage to the product.

•Becarefulnottostriketheglassportionofthedisplaywith tools, etc. The glass can become damaged, and injuriescanoccur.

•Asthisproductisextremelyheavy,wheninstallingitexercisecareregardingscaffolding,andbesuretowearsafety shoes.

•Thisproductisaprecisioninstrument.Besuretoavoidsubjectingittoshock.Shockmaydamagetheproduct.

Wiring Precautions

Warning

•Donotperformwiringwork,turnontheelectricity,etc., when your hands are wet. There is a risk of electric shock.

Caution

•Besuretothoroughlycheckthespecificationstoensurethat the wiring is carried out correctly. Incorrect wiring can cause instrument damage or malfunctions.

•Supplypowercorrectlybasedonthespecifications.Inputting an incorrect power supply can damage the instrument.

•Useapowersupplyforthisproductwhichhasovercurrent protection capability.

Usage Precautions for HART® Devices•Ifoperationusingasecondaryhost(HART®

Communicator, etc.) is necessary, set the communication interval of the primary host (distributed control system, devicemanagementsystem,etc.)to8secondsorlonger,or terminate communication from the primary host before using the secondary host. If the primary host repeatsHART®communicationbefore8secondshaveelapsed, the secondary host may not receive the request (i.e., may not be able to communicate).

•If,asaresultoftheeffectsofelectricalnoiseintheinstallationenvironment,HART®communicationwiththe host is not possible, take countermeasures such as distancing the signal cable from the noise sources, re-evaluating the grounding conditions, and changing the signalcabletoashieldedcable.However,evenifHART®communication is not possible due to noise, control by the 4 to 20 mA analog signal will not be affected.

•Whenusingthisproductinmultidropmode,thereisalimit to the number of units which can be used. If using multidrop, please consult our representative for more details.

Page 6: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

No. SS2-ATSG10-0100Azbil Corporation

6

Performance SpecificationsTheperformancespecifications(accuracy/temperaturecharacteristics/staticpressurecharacteristics)showtheabsolutevaluesofthelowerrangevalue(LRV)*1andupperrangevalue(URV)*2ofthecalibrationrange,aswellasthemaximumvalueχinthe span. The value relative to the span is as follows.(Span-relatedvalue)=(χ-relatedvalue)×(χ)/(span)

JTG940 (General Purpose, Wetted Part Material: SUS316)

Accuracy *3 ±0.1 %±(0.025+0.075×140

χ ) %(χ≥140kPa)(χ<140kPa)

Temperaturecharacteristics*(Shift from the set range) 30°Cchange *3

Combinedshift:(incl.zero/spanshift)

±0.44 %±(0.19+0.25×350χ ) %

(χ≥350kPa)(χ<350kPa)

JTG940 (Option "J1", Wetted Part Material: SUS316)

Accuracy *3 ±0.04 %±(0.008+0.032×350χ ) %

(χ≥350kPa)(χ<350kPa)

Temperaturecharacteristics*(Shift from the set range) 30°Cchange *3

Combinedshift:(incl.zero/spanshift)

±0.15%±(0.075+0.075×350χ ) %

(χ≥350kPa)(χ<350kPa)

JTG940 (for Oxygen, for Chlorine / Wetted Part Material: SUS316)

Accuracy *3 ±0.075%±0.1 %±(0.025+0.075×140.0

χ ) %

(χ≥1750kPa)(1750kPa>χ≥140kPa)(χ<140kPa)

Temperaturecharacteristics*(Shift from the set range) 30°Cchange *3(-5to+55°Crange)

Combinedshift:(incl.zero/spanshift)

±0.44 % ±(0.19+0.25×350χ ) %

(χ≥350kPa)(χ<350kPa)

JTG940 (General Purpose, for Oxygen, for Chlorine / Wetted Part Material: C-276, Tantalum, SUS316L)

Accuracy *3 ±0.15%±(0.05+0.1×350χ ) %

(χ≥140kPa)(χ<140kPa)

Temperaturecharacteristics*(Shift from the set range) 30°Cchange *3(-5to+55°Crange)

Combinedshift:(incl.zero/spanshift)

±0.85%±(0.35+0.5×350χ ) %

(χ≥350kPa)(χ<350kPa)

JTG960 (General Purpose, for Oxygen, for Chlorine / Wetted Part Material: SUS316)

Accuracy *3 ±0.1 % ±(0.05+0.05× 2.1

χ) %

(χ≥2.1MPa)(χ<2.1MPa)

Temperaturecharacteristics*(Shift from the set range) 30°Cchange *3

Combinedshift:(incl.zero/spanshift)

±0.41 % ±(0.18+0.23×3.5

χ) %

(χ≥3.5MPa)(χ<3.5MPa)

Notes:*1:URVisthemeasuredvaluewhen100%(20mADC)isoutput. *2:LRVisthemeasuredvaluewhen0%(4mADC)isoutput. *3:RangeisURV≥0,LRV≥0

Page 7: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

No. SS2-ATSG10-0100Azbil Corporation

7

JTG960 (for Oxygen, for Chlorine / Wetted Part Material: Alloy C-276, Tantalum, SUS316L)

Accuracy *3 ±0.15%±(0.05+0.1× 2.1

χ ) %(χ≥2.1MPa)(χ<2.1MPa)

Temperature characteristics(Shift from the set range) 30°Cchange

(-5to+55°Crange)

Combinedshift:(incl.zero/spanshift)

±0.85%±(0.35+0.5× 3.5χ ) %

(χ≥3.5MPa)(χ<3.5MPa)

JTG980 (General Purpose, for Oxygen, for Chlorine / Wetted Part Material: SUS316)

Accuracy *3 ±0.1 %±(0.05+0.05× 7

χ ) %(χ≥7MPa)(χ<7MPa)

Temperature characteristics(Shift from the set range) 30°Cchange *3(-5to+55°Crange)

Combinedshift:(incl.zero/spanshift)

±0.41 %±(0.18+0.23× 7

χ ) %(χ≥7MPa)(χ<7MPa)

JTG980 (General Purpose, for Oxygen, for Chlorine / Wetted Part Material: Alloy C-276)

Accuracy *3 ±0.15%±(0.05+0.1× 7

χ ) %(χ≥7MPa)(χ<7MPa)

Temperature characteristics(Shift from the set range) 30°Cchange *3(-5to+55°Crange)

Combinedshift:(incl.zero/spanshift)

±0.85%±(0.35+0.5× 7

χ ) %(χ≥3.5MPa)(χ<3.5MPa)

Notes:*1:URVisthemeasuredvaluewhen100%(20mADC)isoutputted *2:LRVisthemeasuredvaluewhen0%(4mADC)isoutputted *3:RangeisURV≥0,LRV≥0

Page 8: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

No. SS2-ATSG10-0100Azbil Corporation

8

Model number configuration tableFor Low Pressure/for Standard Pressure

4 to 20 mA DC (standard)Digital output (DE protocol) Note 14 to 20 mA DC (HART® communication)

G 1/2, water-tightG 1/2, TIIS special explosion-proof model with 1 cable gland attachedG 1/2, TIIS special explosion-proof model with 2 cable glands attached1/2 NPT, non-explosion-proofNo meterDigital meter linear scale (0 to 100 %)Digital meter engineering unit scaleStandard corrosion-proo�ngHeavy corrosion-proo�ngSilver paint (standard corrosion-proo�ng)Silver paint (heavy corrosion-proo�ng)NoneUpscaleDownscaleNoneCarbon steel (square)SUS304 (square)CF8 (SUS304 equivalent, round)

Mounting bracket

X127

Failure modeXUD

Corrosion-resistant �nish

XBCD

IndicatorsX12

Electrical connection / explosion-proof

X23A

No optionsExternal zero adjustment Note 5Long vent drainFor mounting a high load resistance smart meterElbow x 1 (le�)Elbow x 1 (right)Elbow x 2Moisture-free (incl. oil-free) �nishMoisture-free (incl. oil-free) �nish, high-gradeOil-free �nishHigh performance type Note 6Electric power speci�cationSpecial failure mode (3.2 mA)Variable output saturation pointTest reportMill sheetStrength calculation sheetWithstand pressure and air tight test (general-purpose use)Test report (with traceability certi�cate)Other

X XA 2A 5B 7G 1G 2G 3D 1E 6D 2J 1J 2J 8K 9T 1T 2T 5T 6T 8

123

ABCFGHLMNRST

125

EFHKP

135

Rc 1/2, process upper portionRc 1/2, process lower portionRc1/2, process side portion1/2 NPT internal thread, process upper portion1/2 NPT internal thread, process lower portion1/2 NPT internal thread, process side portionRc 1/4, process upper portionRc 1/4, process lower portionRc 1/4, process side portion1/4 NPT internal thread, process upper portion1/4 NPT internal thread, process lower portion1/4 NPT internal thread, process side portionCarbon SteelSUS304 Note 4SUS630

Regular type (silicone oil)For oxygen service (�uorine oil)For chlorine service (�uorine oil) Note 3

SUS316Alloy C-276TantalumSUS316LTantalum

Main unit:Wetted part

SUS316SUS316SUS316SUS316PVC

Vent /drain plugs

SCS14ASCS14ASCS14ASCS14APVC

Meter bodycover

Bolts and nutsmaterial

Process connection

Sealed liquid

Note 2Note 2Note 2Note 2

Process Wetted Material

Output/communication

format

JTG940SJTG940W (with external terminal box)JTG960SJTG960W (with external terminal box)

35 to 3500 kPa

0.7 to 14 MPa

Measuring span

OptionsAdditional SelectionsSelectionsBasic Model No.

Note 1: Cannot be combined with Failure mode "None," variable output saturation point, or external zero adjustment.Note 2: Meter body cover material: SCS14A (SUS316 equivalent) or SUSF316.Note 3: For wetted part of main unit, only "tantalum" can be selected.Note 4: Cannot be used with JTG960S/W. Maximum working pressure: 1.5 MPa. Bolt and nut material

is SUS304.Note 5: Be sure to select indicators.Note 6: Model JTG940S/W only.

Page 9: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

No. SS2-ATSG10-0100Azbil Corporation

9

For High Pressure

Note 1: Cannot be combined with Failure mode "None," variable output saturation point, or external zero adjustment.

Note 2: Be sure to select indicators.

G 1/2, water-tightG 1/2, TIIS special explosion-proof model with 1 cable gland attachedG 1/2, TIIS special explosion-proof model with 2 cable glands attached1/2 NPT, non-explosion-proofNoneDigital meter linear scale (0 to 100 %)Digital meter engineering unit scaleStandard corrosion-proo�ngHeavy corrosion-proo�ngSilver paint (standard corrosion-proo�ng)Silver paint (heavy corrosion-proo�ng)NoneUpscaleDownscaleNoneCarbon steel (square)SUS304 (square)CF8 (SUS304 equivalent, round)

Mounting bracket

X127

Failure modeXUD

Corrosion-resistant �nish

XBCD

IndicatorsX12

Electrical connection / explosion-proof

X23

123

A

No optionsX XA 2A 5B 7G 1G 1G 3D 1E 6D 2J 2J 8K 9T 1T 2T 5T 6T 8

External zero adjustment Note 2Long vent drainFor mounting a high load resistance smart meterElbow x 1 (le�)Elbow x 1 (right)Elbow x 2Moisture-free (incl. oil-free) �nishMoisture-free (incl. oil-free) �nish, high-gradeOil-free �nishElectric power speci�cationSpecial failure mode (3.2 mA)Variable output saturation pointTest reportMill sheetStrength calculation sheetWithstand pressure and air tight test (general-purpose use)Test report (with traceability certi�cate)Other

ABFGLMRS

12

EF

135

Regular type (silicone oil)For oxygen service (�uorine oil)Rc 1/2, process upper portionRc 1/2, process lower portion1/2 NPT internal thread, process upper portion1/2 NPT internal thread, process lower portionRc 1/4, process upper portionRc 1/4, process lower portion1/4 NPT internal thread, process upper portion1/4 NPT internal thread, process lower portionCarbon steelSUS304SUS630

SUS316Alloy C-276

Wetted part of main unit

SUS316SUS316

Vent/drain plugs

SUSF316SUSF316

Meter body cover

4 to 20 mA DC (standard)Digital output (DE protocol) Note 14 to 20 mA DC (HART® communication)

Bolt and nut material

Process connection

Sealed liquid

Process Wetted Material

Output /communication

format

JTG980S

JTG980W (with external terminal box)

0.7 to 42 MPaMeasuring span

OptionsAdditional SelectionsSelectionsBasic Model No.

Page 10: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

No. SS2-ATSG10-0100Azbil Corporation

10

DimensionsJTG 940S/960S (Upper/Lower Connection)

Round Bracket

Square Bracket

External zero adjustment

(optional)

Electrical conduit connection port

Terminal Connection Diagram

(terminal screw size: M4)

Indicators

(optional)

Electrical conduit connection port

Approx. 6

210 if indicators included

206 if indicators included

265 if indicators included

261 if indicators not included

265 if indicators included

261 if indicators not included

M4 terminal screwfor grounding

Process connection port

4 × M8, depth: 8

Installation dimensions without mounting bracket

Units: mm

When using long vent / drain plug

Page 11: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

No. SS2-ATSG10-0100Azbil Corporation

11

JTG 940S/960S (Side Connection)

Round Bracket

Square Bracket

External zero adjustment

(optional)

Electrical conduit connection port

Terminal Connection Diagram

(terminal screw size: M4)

M4 terminal screwfor grounding

4 x M8, depth: 8

Installation dimensions without mounting bracket

Units: mm

See speci�cations

Electrical conduit connection port

See speci�cations

Process connection port

See speci�cations

Indicators

(optional)

approx. 166

210 if indicators included

206 if indicators not included

265 if indicators included

261 if indicators not included

265 if indicators included

261 if indicators not included

Page 12: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

No. SS2-ATSG10-0100Azbil Corporation

12

JTG 980S (Upper/Lower Output)

Round Bracket

Square Bracket

Units: mm

External zero adjustment

(optional)

Terminal Connection Diagram

(terminal screw size: M4)Electrical conduit connection port

See speci�cations

Electrical conduit connection port

See speci�cations

M4 terminal screwfor grounding

Process connection port See speci�cations

4 x M8, depth: 8

Installation dimensions without mounting bracket

Indicators

(optional)

approx. 178

223 if indicators included219 if indicators not included

278 if indicators included274 if indicators not included

278 if indicators included274 if indicators not included

When using long vent / drain

plug

Page 13: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

No. SS2-ATSG10-0100Azbil Corporation

13

JTG 980S (Side Connection)

Round Bracket

Square Bracket

External zero adjustment

(optional)

Electrical conduit connection port

Electrical conduit connection port

See speci�cations

M4 terminal screwfor grounding

4 x M8, depth: 8

Installation dimensions without mounting bracket

Units: mm

Terminal Connection Diagram

(terminal screw size: M4)

See speci�cations

approx. 178

278 if indicators included

274 if indicators not included

223 if indicators included

219 if indicators not included

278 if indicators included

274 if indicators not included

Indicators

(optional)

Process connection port

See speci�cations

Page 14: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

No. SS2-ATSG10-0100Azbil Corporation

14

JTG 940S/960S (Tantalum, SUS316L)

Upper/Lower ConnectionExternal zero adjustment

(optional)

Electrical conduit connection port

Terminal Connection Diagram

(terminal screw size: M4)

See speci�cations

Electrical conduit connection port

See speci�cations

Process connection port

See speci�cations

4 x M8 depth: 8

Installation dimensions without mounting bracket

Units: mmM4 terminal screw

for grounding

approx. 1662B pipe

210 if indicators included206 if indicators included

277 if indicators included273 if indicators included

Indicators

(optional)

External zero adjustment

(optional)

Electrical conduit connection port

Terminal Connection Diagram

(terminal screw size: M4)

See speci�cations

Electrical conduit connection port

See speci�cations

Process connection port

See speci�cations

4 x M8, depth: 8

Installation dimensions without mounting bracket

M4 terminal screwfor grounding

approx. 1662B pipe

210 if indicators included206 if indicators not included

277 if indicators included273 if indicators not included

Indicators

(optional)

When using long vent / drain

plug

Page 15: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

No. SS2-ATSG10-0100Azbil Corporation

15

JTG 940S/960S (Cover Material: PVC)

Units: mm

External zero adjustment

(optional)

Electrical conduit connection port

Terminal Connection Diagram

(terminal screw size: M4)

See speci�cations

Electrical conduit connection port

See speci�cations

M4 terminal screwfor grounding

Process connection port

See speci�cations

4 x M8, depth: 8

Installation dimensions without mounting bracket

Indicators

(optional)

2B pipe

(277 if indicators included)

(273 if indicators not included)

210 if indicators included206 if indicators not included

Page 16: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

No. SS2-ATSG10-0100Azbil Corporation

16

JTG 940W/960W (Upper/Lower Connection)

Round Bracket

Square Bracket

Terminal Connection Diagram

(terminal screw size: M4)

Process connection port

See speci�cations

4 x M8, depth: 8

Installation dimensions without mounting bracket

Units: mm

M4 terminal screwfor grounding

Indicators

(optional)

External zero adjustment

(optional)

306 if indicators included

302 if indicators not included

306 if indicators included

302 if indicators not included

Electrical conduit connection port

See speci�cations

Electrical conduit connection port

See speci�cations

When using long vent / drain

plug

Page 17: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

No. SS2-ATSG10-0100Azbil Corporation

17

JTG 940W/960W (Side Connection)

Round Bracket

Square Bracket

Terminal Connection Diagram

(terminal screw size: M4)

4 x M8, depth: 8

Installation dimensions without mounting bracket

Units: mm

M4 terminal screwfor grounding

Indicators

(optional)Electrical conduit connection port

See speci�cations

Electrical conduit connection port

See speci�cations

External zero adjustment

(optional)

Process connection port

See speci�cations

306 if indicators included

302 if indicators not included

306 if indicators included

302 if indicators not included

Page 18: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

No. SS2-ATSG10-0100Azbil Corporation

18

JTG 980W (Upper/Lower Connection)

Round Bracket

Square Bracket

Terminal Connection Diagram

(terminal screw size: M4)

M4 terminal screwfor grounding

Process connection port See speci�cations

4 x M8, depth: 8

Installation dimensions without mounting bracket

Units: mm

Indicators(optional)

External zero adjustment

(optional)

Electrical conduit connection port

See speci�cations

Electrical conduit connection port

See speci�cations

319 if indicators included

315 if indicators not included

319 if indicators included

315 if indicators not included

When using long vent / drain

plug

Page 19: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

No. SS2-ATSG10-0100Azbil Corporation

19

JTG 980W (side connection)

Round Bracket

Square Bracket

Terminal Connection Diagram

(terminal screw size: M4)

M4 terminal screwfor grounding

Indicators (optional)Electrical conduit

connection port See speci�cations

Electrical conduit connection port

See speci�cations

External zero adjustment(optional)

Process connection port

See speci�cations

Installation dimensions without mounting bracket

Units: mm

4 x M8 depth: 8

319 if indicators included

315 if indicators not included

319 if indicators included

315 if indicators not included

Page 20: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

No. SS2-ATSG10-0100Azbil Corporation

20

JTG 940W/960W (Tantalum, SUS316L)

Side Connection

Upper/Lower Connection

Terminal Connection Diagram

(terminal screw size: M4)

M4 terminal screw

for grounding

Process connection port

See speci�cations

Installation dimensions

without mounting bracket

Units: mm 4 x M8, depth: 8

Electrical conduit connection port

See speci�cations

Electrical conduit connection port

See speci�cations

External zero adjustment

(optional)

External zero adjustment

(optional)

2B pipe

2B pipe

4 x M8, depth: 8

Installation dimensions without mounting bracket

Terminal Connection Diagram

(terminal screw size: M4)

M4 terminal screw

for grounding

Process connection port

See speci�cations

Process connection port

See speci�cations

Electrical conduit connection port

See speci�cations

When using long vent / drain

plug

Page 21: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

No. SS2-ATSG10-0100Azbil Corporation

21

JTG 940W/960W (Case Cover Material: PVC)

Terminal Connection Diagram

(terminal screw size: M4)

M4 terminal screwfor grounding

4 x M8, depth: 8

Installation dimensions without mounting bracket

Units: mm

Process connection port

See speci�cations

External zero adjustment

(optional)

2B pipe

Electrical conduit connection port

See speci�cations

Electrical conduit connection port

See speci�cations

Indicators

(optional)

Page 22: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

No. SS2-ATSG10-0100Azbil Corporation

22

Page 23: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

No. SS2-ATSG10-0100Azbil Corporation

23

Page 24: AT9000 Advanced Transmitter SuperAce JTG Series Gauge ...

No. SS2-ATSG10-0100Azbil Corporation

24

Please read the "Terms and Conditions" from the following URL before ordering or use:

http://www.azbil.com/products/bi/order.html

(10)

1-12-2 Kawana, FujisawaKanagawa 251-8522 Japan

Specifications are subject to change without notice.

No part of this publication may be reproduced or duplicated without the prior written permission of Azbil Corporation.

http://www.azbil.com/1st edition: May 2015