ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions...
Transcript of ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions...
![Page 1: ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions met prior to programming MRI mode or enabling the SJM MRI Activator device. Capture](https://reader033.fdocuments.in/reader033/viewer/2022053006/5f09b75e7e708231d4282cca/html5/thumbnails/1.jpg)
SJM-EDTR-0216-0025 | Item approved for global use.SJM-EDTR-0216-0025 | Item approved for global use.
ASSURITY MRI™ PACEMAKERProgramming MRI Mode
1
![Page 2: ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions met prior to programming MRI mode or enabling the SJM MRI Activator device. Capture](https://reader033.fdocuments.in/reader033/viewer/2022053006/5f09b75e7e708231d4282cca/html5/thumbnails/2.jpg)
SJM-EDTR-0216-0025 | Item approved for global use. 2
ENABLE MRI SETTINGS
SJM MRI Activator™ handheld device Merlin™ Patient Care System (PCS)
![Page 3: ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions met prior to programming MRI mode or enabling the SJM MRI Activator device. Capture](https://reader033.fdocuments.in/reader033/viewer/2022053006/5f09b75e7e708231d4282cca/html5/thumbnails/3.jpg)
SJM-EDTR-0216-0025 | Item approved for global use.
Saves time, effort, and inconvenience
3
MRI PATIENT WORKFLOW
Traditional MRI patient workflow processDevice is
programmed to
temporary MRI
settings
Patient needs an MRI
scan
Patient has MRI scan
MR
Patient goes to
cardiology center or
physician goes to MRI
clinic
Patient goes homePatient goes to
cardiology center or
physician goes to MRI
clinic
Device is
programmed back to
pre MRI scan settings
Patient needs an MRI
scanPatient has MRI scan
MR
Patient goes home
MRI patient workflow with SJM MRI Activator™ handheld device
Patient goes to
cardiology center for
device check
![Page 4: ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions met prior to programming MRI mode or enabling the SJM MRI Activator device. Capture](https://reader033.fdocuments.in/reader033/viewer/2022053006/5f09b75e7e708231d4282cca/html5/thumbnails/4.jpg)
SJM-EDTR-0216-0025 | Item approved for global use. 4
NOMINAL MRI SETTINGS
Parameter Setting
MRI Mode (dual-chamber devices) DOO
MRI Mode (single-chamber devices) VOO
MRI Base Rate 85 bpm
MRI Paced AV Delay 120 ms
MRI Pulse Amplitude 5.0 V
MRI Pulse Width 1.0 ms
MRI Pulse Configuration Bipolar
![Page 5: ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions met prior to programming MRI mode or enabling the SJM MRI Activator device. Capture](https://reader033.fdocuments.in/reader033/viewer/2022053006/5f09b75e7e708231d4282cca/html5/thumbnails/5.jpg)
SJM-EDTR-0216-0025 | Item approved for global use.
PROGRAMMING MRI MODEProgramming Tutorial
5
![Page 6: ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions met prior to programming MRI mode or enabling the SJM MRI Activator device. Capture](https://reader033.fdocuments.in/reader033/viewer/2022053006/5f09b75e7e708231d4282cca/html5/thumbnails/6.jpg)
6
![Page 7: ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions met prior to programming MRI mode or enabling the SJM MRI Activator device. Capture](https://reader033.fdocuments.in/reader033/viewer/2022053006/5f09b75e7e708231d4282cca/html5/thumbnails/7.jpg)
SJM-EDTR-0216-0025 | Item approved for global use.
MRI SUMMARY REPORT
MRI Settings Disabled MRI Settings Enabled
7
![Page 8: ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions met prior to programming MRI mode or enabling the SJM MRI Activator device. Capture](https://reader033.fdocuments.in/reader033/viewer/2022053006/5f09b75e7e708231d4282cca/html5/thumbnails/8.jpg)
SJM-EDTR-0216-0025 | Item approved for global use.
ENABLE SJM MRI ACTIVATOR™ HANDHELD DEVICEProgramming Tutorial
8
![Page 9: ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions met prior to programming MRI mode or enabling the SJM MRI Activator device. Capture](https://reader033.fdocuments.in/reader033/viewer/2022053006/5f09b75e7e708231d4282cca/html5/thumbnails/9.jpg)
9
![Page 10: ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions met prior to programming MRI mode or enabling the SJM MRI Activator device. Capture](https://reader033.fdocuments.in/reader033/viewer/2022053006/5f09b75e7e708231d4282cca/html5/thumbnails/10.jpg)
SJM-EDTR-0216-0025 | Item approved for global use.
MRI CHECKLIST
10
![Page 11: ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions met prior to programming MRI mode or enabling the SJM MRI Activator device. Capture](https://reader033.fdocuments.in/reader033/viewer/2022053006/5f09b75e7e708231d4282cca/html5/thumbnails/11.jpg)
SJM-EDTR-0216-0025 | Item approved for global use. 11
MRI CHECKLIST – DUAL CHAMBER (DOO)
![Page 12: ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions met prior to programming MRI mode or enabling the SJM MRI Activator device. Capture](https://reader033.fdocuments.in/reader033/viewer/2022053006/5f09b75e7e708231d4282cca/html5/thumbnails/12.jpg)
SJM-EDTR-0216-0025 | Item approved for global use. 12
MRI CHECKLIST – PACING OFF
![Page 13: ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions met prior to programming MRI mode or enabling the SJM MRI Activator device. Capture](https://reader033.fdocuments.in/reader033/viewer/2022053006/5f09b75e7e708231d4282cca/html5/thumbnails/13.jpg)
SJM-EDTR-0216-0025 | Item approved for global use. 13
MRI CHECKLIST – OUT OF RANGE VALUES
![Page 14: ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions met prior to programming MRI mode or enabling the SJM MRI Activator device. Capture](https://reader033.fdocuments.in/reader033/viewer/2022053006/5f09b75e7e708231d4282cca/html5/thumbnails/14.jpg)
SJM-EDTR-0216-0025 | Item approved for global use.
DISABLE MRI MODEProgramming Tutorial
14
![Page 15: ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions met prior to programming MRI mode or enabling the SJM MRI Activator device. Capture](https://reader033.fdocuments.in/reader033/viewer/2022053006/5f09b75e7e708231d4282cca/html5/thumbnails/15.jpg)
15
![Page 16: ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions met prior to programming MRI mode or enabling the SJM MRI Activator device. Capture](https://reader033.fdocuments.in/reader033/viewer/2022053006/5f09b75e7e708231d4282cca/html5/thumbnails/16.jpg)
SJM-EDTR-0216-0025 | Item approved for global use.
MERLIN.NET™ PATIENT CARE NETWORK ALERT: MRI Settings On
16
![Page 17: ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions met prior to programming MRI mode or enabling the SJM MRI Activator device. Capture](https://reader033.fdocuments.in/reader033/viewer/2022053006/5f09b75e7e708231d4282cca/html5/thumbnails/17.jpg)
SJM-EDTR-0216-0025 | Item approved for global use. 17
This alert is to highlight that the MRI settings weren’t disabled after the scan session was complete. The patients’ MRI settings should be turned OFF and permanent parameters restored as soon as possible.
This alert is automated, not set up by the user.
If MRI settings are not disabled and the patient goes home, an alert will appear on Merlin.net™
PCN indicating “MRI settings on”.
MRI SETTINGS ON ALERT
![Page 18: ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions met prior to programming MRI mode or enabling the SJM MRI Activator device. Capture](https://reader033.fdocuments.in/reader033/viewer/2022053006/5f09b75e7e708231d4282cca/html5/thumbnails/18.jpg)
SJM-EDTR-0216-0025 | Item approved for global use. 18
When you click on the Alert flag , and if the alert is due to the MRI settings being left ON, you will
see the MRI Summary and Alert Summary reports.
REPORTS
![Page 19: ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions met prior to programming MRI mode or enabling the SJM MRI Activator device. Capture](https://reader033.fdocuments.in/reader033/viewer/2022053006/5f09b75e7e708231d4282cca/html5/thumbnails/19.jpg)
SJM-EDTR-0216-0025 | Item approved for global use. 19
![Page 20: ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions met prior to programming MRI mode or enabling the SJM MRI Activator device. Capture](https://reader033.fdocuments.in/reader033/viewer/2022053006/5f09b75e7e708231d4282cca/html5/thumbnails/20.jpg)
SJM-EDTR-0216-0025 | Item approved for global use. 20
There are two ways to enable MRI mode (Merlin™ PCS or SJM MRI Activator™ handheld device)
The MRI Checklist must be completed and all conditions met prior to programming MRI mode or
enabling the SJM MRI Activator device.
Capture thresholds ≤2.5V @ 0.5ms
Bipolar impedances within range
SJM Leads are labeled for MRI
No additional cardiac hardware present
Merlin.net™ PCN has a new alert should a device be left in MRI mode after the patients MRI scan
SUMMARY
![Page 21: ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions met prior to programming MRI mode or enabling the SJM MRI Activator device. Capture](https://reader033.fdocuments.in/reader033/viewer/2022053006/5f09b75e7e708231d4282cca/html5/thumbnails/21.jpg)
![Page 22: ASSURITY MRI™ PACEMAKER - Abbott€¦ · The MRI Checklist must be completed and all conditions met prior to programming MRI mode or enabling the SJM MRI Activator device. Capture](https://reader033.fdocuments.in/reader033/viewer/2022053006/5f09b75e7e708231d4282cca/html5/thumbnails/22.jpg)
SJM-EDTR-0216-0025 | Item approved for global use.
Rx Only
Brief Summary: Prior to using these devices, please review the Instructions for Use for a complete listing of
indications, contraindications, warnings, precautions, potential adverse events and directions for use.
Unless otherwise noted, ™ indicates that the name is a trademark of, or licensed to St. Jude Medical or one
of its subsidiaries. ST. JUDE MEDICAL and the nine-squares symbol are trademarks and service marks of
St. Jude Medical, Inc. and its related companies. © 2016 St. Jude Medical, Inc. All Rights Reserved.
22
You may now close the browser window.