Aspenengineering Install Guide Suitev7_3-Inst

214
8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 1/214 Aspen Engineering Suite V7.3 Installation Guide

Transcript of Aspenengineering Install Guide Suitev7_3-Inst

Page 1: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 1/214

Aspen Engineering Suite V7.3

Installation Guide

Page 2: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 2/214

Page 3: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 3/214

Contents iii

Contents1 Introduction.........................................................................................................9

aspenONE Overview .........................................................................................9Packaging .............................................................................................9DVDs ....................................................................................................9

Start Installation ....................................................................................9AspenTech Installation Browser.............................................................. 10Aspen Documentation DVD....................................................................10

Installing License Manager Before Installing Applications..................................... 10

Installation Process ........................................................................................11Important Installation Change for V7.3 ............................................................. 11Related Documentation................................................................................... 11

aspenONE V7.3 Deployment Guide ......................................................... 11Software License Manager (SLM) Installation and Reference Guide ............. 11 Aspen Engineering What’s New in V7.3 ................................................... 12 Aspen Framework Server V7.3 Installation Manual  ................................... 12

 Aspen Local Security Server V7.3 Installation Manual  ............................... 12 Aspen Engineering Known Issues in V7.3 ................................................ 12Other Related Documents......................................................................12

Technical Support ..........................................................................................12

2 Pre-installation ..................................................................................................15

Overview....................................................................................................... 15Product Name Changes ................................................................................... 15

Aspen Engineering Installation Options and Sub-Options .....................................19

Pre-installation Checklist ................................................................................. 23Checking Aspen System Requirements.............................................................. 23

Aspen Engineering V7.3 Hardware Requirements ..................................... 23

Checking Software Requirements ..................................................................... 24

Aspen Engineering V7.3 Software Requirements ...................................... 24Checking the Service Pack Version ................................................................... 25

Checking Virtual Memory................................................................................. 25

Checking Account Privileges ............................................................................25Checking Product-Specific Requirements and Dependencies.................................26

Aspen Adsorption Additional Requirements .............................................. 28

Aspen Basic Engineering Additional Requirements ....................................28Aspen Batch Process Developer Additional Requirements .......................... 30Aspen Chromatography Additional Software Requirements ........................30Aspen Custom Modeler Additional Software Requirements .........................30

Aspen Economic Evaluation Additional Requirements ................................ 31Aspen Exchanger Design and Rating Additional Requirements....................31Aspen HYSYS Additional Software Requirements ...................................... 31

Aspen HYSYS Petroleum Refining Additional Software Requirements........... 32

Aspen HYSYS Upstream Additional Software Requirements........................ 32

Page 4: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 4/214

iv Contents

Aspen OnLine Additional Software Requirements...................................... 32

Aspen Online Deployment Additional Software Requirements..................... 33

Aspen Plus Additional Software Requirements .......................................... 35Aspen Plus CatCracker Additional Software Requirements .........................35Aspen Plus Dynamics Additional Software Requirements ........................... 36

Aspen Plus Hydrocracker Additional Software Requirements ...................... 36

Aspen Plus Hydrotreater Additional Software Requirements ....................... 36Aspen Plus Reformer Additional Software Requirements ............................ 36

Aspen Process Manual Additional Requirements ....................................... 36Aspen Properties Additional Software Requirements ................................. 37

Aspen Properties Enterprise Database Additional Software Requirements .... 38Aspen Properties Mobile Additional Software Requirements........................ 38

Aspen Simulation Workbook Additional Software Requirements.................. 38

Aspen Utilities Planner Additional Software Requirements.......................... 39Aspen Utilities On-Line Optimizer Additional Software Requirements........... 39

Recommended Installation Sequence................................................................ 39

3 Installing Aspen Products ..................................................................................41

Overview....................................................................................................... 41SLM Client Tools............................................................................................. 41Installing Aspen Products ................................................................................ 41

Important Installation Change for V7.3 ............................................................. 41Installation Options ........................................................................................42

Valid Aspen Product Installation Options ................................................. 42Standard Installation ...................................................................................... 44

Before You Begin.................................................................................. 44Standard Installation Using the Aspen Engineering DVD ............................ 45Configuring Aspen Products at Install Time.............................................. 55

Ready to Install ................................................................................... 57

Setup Complete ................................................................................... 58Client-Server Installation ................................................................................ 59

Overview............................................................................................. 59Before You Begin.................................................................................. 60Client-Server Installation Using the Aspen Engineering DVD ...................... 61Installing Aspen Software on a Server .................................................... 61

Installing the Software.......................................................................... 61

Configuring Aspen Products at Install Time.............................................. 71Ready to Install ................................................................................... 73Setup Complete ................................................................................... 74

Configuring a Windows Server as an Aspen Host ................................................ 75Adding Windows Server Accounts...........................................................76

Installing Aspen Products on User PCs .............................................................. 77

Configuring Installed Aspen Products on User PCs .............................................. 77

Specifying a Remote Server.............................................................................77Verifying Client–Server Communication ............................................................ 80Verifying the Installation ................................................................................. 81

Configuring Installed Aspen Products ................................................................ 81

4 Individual Product Installation Notes.................................................................83

Installation Notes ........................................................................................... 83Aspen Basic Engineering Installation Notes ........................................................ 83

Installation Types.................................................................................84

Page 5: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 5/214

Contents v

Aspen Basic Engineering Standard Installation Notes ................................ 85

Aspen Basic Engineering Client Installation Notes .....................................88

Aspen Basic Engineering Server Installation Notes.................................... 90Aspen Basic Engineering Server Installation............................................. 90Uninstalling and/or Reinstalling ..............................................................92

Disconnecting Users from the Server ...................................................... 92

Aspen Batch Process Developer Installation Notes .............................................. 92Aspen Exchanger Design and Rating Installation Notes ....................................... 93

Aspen Economic Evaluation Installation Notes .................................................... 94Aspen HYSYS Installation Notes ....................................................................... 95

Installing the Aspen Properties Enterprise Database ................................. 95Verifying the Aspen Properties Enterprise Database Installation ................. 97

Installing Aspen HYSYS Dynamics Runtime.............................................. 98

Installing OLI Engine for HEO................................................................. 98OLI Engine in Aspen HYSYS ................................................................... 99

Installing............................................................................................. 99Aspen OnLine Installation Notes ..................................................................... 100

Aspen Online Deployment Installation Notes.................................................... 101Aspen Plus Installation Notes ......................................................................... 104

Installation Details for Aspen Plus and Aspen Properties.......................... 104Installing the Aspen Properties Enterprise Database ............................... 104Aspen Properties Mobile Installation Notes............................................. 105Aspen OLI Interface Installation Notes .................................................. 106

Installing OLI Engine for Aspen Plus ..................................................... 107

OLI Engine in Aspen Plus..................................................................... 108HardLock Device Driver Installation Script ............................................. 109

Aspen Process Manual Installation Notes ......................................................... 110Server Configuration Notes: ................................................................ 110

Application Configuration .................................................................... 110Aspen Simulation Workbook Installation Notes................................................. 111

Version Coexistence ........................................................................... 112

Disabling Add-in by Default ................................................................. 112Aspen Utilities Planner Installation Notes......................................................... 112

Aspen Utilities On-Line Optimizer Installation Notes.......................................... 112Computer Configuration (Installation) Type ........................................... 113

Microsoft Excel Interface Setup ............................................................ 113

5 Verifying and Configuring Aspen Products .......................................................115

Overview..................................................................................................... 115

Aspen Products That Use Aspen Properties ............................................ 117Configuring Microsoft SQL Server or SQL Express................................... 117Verifying the Aspen Properties Enterprise Database Installation ............... 118

Aspen Adsorption ......................................................................................... 119

Verifying an Aspen Adsorption Installation............................................. 119Verifying an Aspen Adsorption Installation that Uses Aspen Properties ...... 120Aspen Basic Engineering ............................................................................... 121

Verifying an Aspen Basic Engineering Installation ................................... 121

Configuring Aspen Basic Engineering .................................................... 123Aspen Batch Distillation ................................................................................ 124

Verifying an Aspen Batch Distillation Installation .................................... 124

Aspen Batch Process Developer...................................................................... 125Configuring Microsoft SQL Server or SQL Express................................... 125

Page 6: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 6/214

vi Contents

Verifying the Aspen Properties Enterprise Database Installation ............... 126

Aspen Chromatography................................................................................. 126

Verifying an Aspen Chromatography Installation .................................... 126Aspen Custom Modeler ................................................................................. 127

Verifying the Server Installation........................................................... 127

Verifying an Aspen Custom Modeler Installation ..................................... 128

Verifying an Aspen Custom Modeler Installation with Aspen Properties...... 128Aspen Exchanger Design and Rating ............................................................... 130

Verifying an Aspen Exchanger Design and Rating Installation................... 130Configuring Microsoft SQL Server or SQL Express................................... 131

Verifying the Aspen Properties Enterprise Database Installation ............... 131Aspen HYSYS............................................................................................... 132

Verifying an Aspen HYSYS Installation .................................................. 132

Verifying an Aspen HYSYS Upstream Installation.................................... 133Verifying an Aspen HYSYS Petroleum Refining Installation ....................... 133

Configuring Microsoft SQL Server or SQL Express................................... 134Verifying an Aspen HYSYS Petroleum Refining Installation ....................... 135

Configuring Microsoft SQL Server or SQL Express................................... 135Verifying the Aspen Properties Enterprise Database Installation ............... 136

Aspen MUSE ................................................................................................ 137Verifying an Aspen MUSE Installation.................................................... 137

Aspen OnLine .............................................................................................. 137Configuring Aspen OnLine ................................................................... 137

Verifying an Aspen OnLine Installation .................................................. 139

Aspen Plus .................................................................................................. 140Configuring Microsoft SQL Server or SQL Express................................... 141

Verifying the Aspen Properties Enterprise Database Installation ............... 141Verifying an Aspen Plus/Aspen Polymers Installation............................... 142

Using the FORTRAN Compiler with Aspen Plus........................................ 143Verifying the Installation of the FORTRAN Compiler ................................ 143

Verifying an Aspen OLI Interface Installation ......................................... 144

Verifying an Aspen Distillation Synthesis feature of Aspen Plus Installation 144Aspen Plus CatCracker/Hydrocracker/ Hydrotreater/Reformer ............................ 146

Configuring an Aspen Plus CatCracker/Hydrocracker/ Hydrotreater/ReformerInstallation........................................................................................ 146

Configuring Microsoft SQL Server or SQL Express................................... 147Verifying the Aspen Properties Enterprise Database Installation ............... 147

Aspen Plus Dynamics.................................................................................... 148

Verifying an Aspen Plus Dynamics Installation........................................ 148Aspen Properties .......................................................................................... 149

Verifying an Aspen Properties Installation.............................................. 149Configuring and Verifying an Aspen Properties Mobile Installation............. 150

Setting Up the Aspen Properties Web Interface ...................................... 153Configuring IIS for the Aspen Properties Web Interface........................... 153

Setting Up Directory Security............................................................... 154Providing Access to Out-Of-Process (OOP) COM Objects.......................... 155

Restricting User Access Using File Permissions ....................................... 156

Setting Up Properties Web Interface User Folders................................... 156Running the Aspen Properties Web Interface ......................................... 157

Configuring Excel for Performing Property Calculations............................ 157Aspen Remote Simulation Service .................................................................. 158

Configuring Aspen Remote Simulation Service ....................................... 158Running Aspen Remote Simulation Service (ARSS)................................. 158

Page 7: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 7/214

Contents vii

Aspen Solubility Modeler ............................................................................... 159

Configuring an Aspen Solubility Modeler Installation ............................... 159

Aspen Utilities Planner .................................................................................. 164Aspen Utilities On-Line Optimizer ................................................................... 164

Verifying an Aspen Utilities Planner Installation...................................... 164

6 Adding and Upgrading Aspen Products.............................................................167

Adding Aspen Engineering Products ................................................................ 167Upgrading Aspen Engineering Products ........................................................... 167

Before You Upgrade............................................................................ 167

Product Upgrade Task Summary .......................................................... 168

Upgrading Aspen Products................................................................... 169Repairing or Modifying Products ........................................................... 169After You Upgrade .............................................................................. 169

Re-registering CAPE-OPEN Property Packages........................................ 170

7 Repairing Aspen Products ................................................................................171

Repairing Products and Subfeatures ............................................................... 171

Setup Complete ................................................................................. 177

8 Removing Aspen Products................................................................................179

Before You Remove Any Aspen Product........................................................... 179

Overview..................................................................................................... 179

Removing Aspen Products ................................................................... 179After You Remove Aspen Products.................................................................. 185

Using Excel After Uninstalling Aspen Basic Engineering ........................... 186

9 Troubleshooting ...............................................................................................187

Common Problems ....................................................................................... 187

Checking Installation Account Privileges ................................................ 187Other Troubleshooting Tips.................................................................. 187

Error Messages ............................................................................................ 188

License Errors.................................................................................... 188Client-Server Installations ................................................................... 188

Troubleshooting Installation of Aspen Products ................................................ 188

.NET Framework Error ........................................................................ 188Installation Stalls When Installing Aspen Simulation Workbook or AspenUtilities Planner.................................................................................. 188

Troubleshooting SQL Server Problems ............................................................ 189

Verifying the Aspen Properties Enterprise Database Installation ............... 190Troubleshooting Individual Aspen Products ...................................................... 191

Troubleshooting Aspen Adsorption, Aspen Chromatography, Aspen Custom

Modeler, and Aspen Plus Dynamics....................................................... 191Troubleshooting Aspen Basic Engineering .............................................. 192Troubleshooting Aspen Batch Process Developer .................................... 194

Troubleshooting Aspen Economic Evaluation (Aspen Process Economic

Analyzer, Aspen Capital Cost Estimator, Aspen In-Plant Cost Estimator) ... 195Troubleshooting Aspen Online Deployment ............................................ 196Troubleshooting Aspen Plus ................................................................. 197

Configuring Microsoft SQL Server or SQL Express................................... 197

Verifying the Aspen Properties Enterprise Database Installation ............... 198

Page 8: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 8/214

viii Contents

Troubleshooting Aspen Remote Simulation Server .................................. 204

Troubleshooting Aspen Simulation Workbook......................................... 205

Troubleshooting Aspen Solubility Modeler.............................................. 207

10 Glossary .........................................................................................................209

Index ..................................................................................................................211

Page 9: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 9/214

1 Introduction 9

1 Introduction

aspenONE Overview

Packaging

Included in your package from AspenTech, you will find the following items

that you will need prior to installation:

  Letter notifying you which products are licensed.

  Package of DVDs (see “Installation DVDs” below).

  License file (only if a dongle has also been shipped to you).

  Instructions on how to run the License Utility (if a dongle is not used).

DVDs

The DVDs associated with the aspenONE release include:

aspenONE Documentation DVD  – includes all AspenTech documentation. Thisincludes all manuals (in PDF format) and standalone versions of Help files.This DVD is not used in the product installation process, but can be usedseparately to browse the documentation and install PDF documentation.

aspenONE Product DVDs  – includes a number of DVDs that contain theinstallations for Aspen products. For a complete description of the contents of those DVDs, refer to the   aspenONE Deployment Guide.

Start Installation

To begin an installation, insert the appropriate DVD into your DVD drive. You

will be prompted to configure your license information prior to installation.Aspen Administration components (SLM Server and Aspen Security (AspenFramework)) and some Aspen Engineering products do not require a license

to install. For all others, you must configure the license information beforeyou can install. When the products are determined to have valid licenses, theAspenTech Installation Browser will request the products or product set that

you want to install and request applicable DVDs as needed. Alternatively, DVD

content can be shared from a network server.

Page 10: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 10/214

10 1 Introduction

AspenTech Installation Browser

The AspenTech Installation Browser provides a mechanism for users tovalidate their product licenses and browse through the products that they are

licensed for prior to installation. The AspenTech Installation Browser contains

two tabs,  Administration  and Products.

From the  Administration  tab, you can install the Aspen Administrationproducts – Aspen SLM, Aspen Security (Aspen Framework), Aspen SLM tools,

and aspenONE Diagnostics.

From the  Products  tab, you can browse for and install individual products.The Installation Browser will guide you in determining your licensed products

based on your license configuration.

The AspenTech Installation Browser also includes links to Aspen Technologysupport centers and web sites for contact information, product updates and

other resources. A link is also provided to easily access the license

configuration wizard to determine which products you are licensed forinstallation.

Clicking  Install  starts the process during which you will select the products tobe installed on your computer.

For more information, see the   aspenONE Deployment Guide.

Aspen Documentation DVD

Before installing any AspenTech product, be sure to print and read theinstallation guide and release notes documentation for each product you

intend to install. All AspenTech installation and reference documents (in PDFformat) and standalone versions of Help files are included on the  aspenONE Documentation DVD.

Each product-specific installation guide contains critical information about

system requirements, product dependencies, and post-installationconfiguration procedures. The release notes for each product contain

information on new features, software fixes, and known problems and

workarounds.

Installing License ManagerBefore Installing Applications

Normally you may need to install SLM (Software License Manager) productsbefore installing Aspen applications. For information on how to install SLM(Software License Manager) products, see   Software License Manager (SLM)Installation and Reference Guide, which is contained on the  Documentation

DVD.

Page 11: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 11/214

1 Introduction 11

Installation ProcessTo begin an installation, insert any DVD into your DVD drive. The AspenTechInstaller requests the products or product set that you want to install andrequests applicable DVDs. Alternatively, DVD content can be shared from a

network server.

To install Aspen Engineering Products, insert DVD 1.

For example, if you are performing a new installation of Aspen Engineeringproducts only, the AspenTech Installer installs infrastructure components

(using the Infrastructure DVD) followed by Aspen Engineering components.

Important Installation Change

for V7.3With Aspen Engineering Suite V7.3, there are two options for installing Aspen

Engineering Products.

If you are installing:

o   Aspen Exchanger Design and Rating V7.3.1

o   Aspen Economic Evaluation V7.3.1

o   Aspen Properties Mobile V7.3

  Click  Products | Aspen Engineering (for Upgrade) | Install.

If you are installing any other product:

  Click  Products | Aspen Engineering | Install.

Related Documentation

Note: All documentation is contained on the  Documentation   DVD.

aspenONE V7.3 Deployment GuideaspenONE V7.3 Deployment Guide  provides an overview of the installation

options and details about the installation process.

Software License Manager (SLM) Installation and Reference GuideSoftware License Manager (SLM) Installation and Reference Guide, the license

manager software used with aspenONE.

Note: You must install and enable Software License Manager (SLM) before

installing Aspen products.

Page 12: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 12/214

12 1 Introduction

 Aspen Engineering What’s New in V7.3 Aspen Engineering What’s New in V7.3  highlights new products and featureswith the aspenONE   release of Aspen Engineering.

 Aspen Framework Server V7.3 InstallationManual  Aspen Framework Server V7.3 Installation Manual , which is contained on theDocumentation  DVD, provides step-by-step instructions for installing andconfiguring Aspen Framework.

 Aspen Local Security Server V7.3 Installation Manual  Aspen Local Security Server V7.3 Installation Manual , which is contained on

the  Documentation   DVD, provides step-by-step instructions for installingand configuring the Aspen Local Security (ALS) Server, which provides role-

based security for AspenTech point solutions.

 Aspen Engineering Known Issues in V7.3 Aspen Engineering Known Issues in V7.3  describes known issues andworkarounds for Aspen Engineering products.

Other Related Documents

Installation Guides for individual Aspen Manufacturing and Supply Chain

products are on the  Documentation  DVD.

Note: For Aspen PIMS Installation information, see the  DocumentationDVD.

Technical SupportAspenTech customers with a valid license and software maintenance

agreement can register to access the online AspenTech Support Center at:

http://support.aspentech.com

This Web support site allows you to:

  Access current product documentation

  Search for tech tips, solutions, and frequently asked questions (FAQs)

  Search for and download service packs and product updates

  Submit and track technical issues

  Send suggestions

  Report product defects

Page 13: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 13/214

1 Introduction 13

  Review lists of known deficiencies and defects

Registered users can also subscribe to our Technical Support e-Bulletins.

These are used to alert users to important technical support information suchas:

  Technical advisories

  Product updates and releases

Customer support is also available by phone, fax, and email. The most up-to-date contact information is available at the AspenTech Support Center athttp://support.aspentech.com.

Page 14: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 14/214

14 1 Introduction

Page 15: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 15/214

2 Pre-installation 15

2 Pre-installation

OverviewThis chapter provides an overview of the installation requirements and

installation options.

Product Name ChangesWith the release of aspenONE V7.0, AspenTech made the decision to provide

more functional names to several of its Process Engineering products. Thenew names reflect the function/role that each product performs as part of the

overall Aspen Engineering. The installation has also been re-organized to

reflect functional groups. Use the chart below to see the new product namesand their corresponding installation selections.

Product NameRelease 2006.5

Product NameV7.0 onwards

Install Mapping(What to Install)

Required InstallOption Selection

Aspen Acol+™   Aspen Air CooledExchanger

Exchanger Design AndRating

---

Aspen Adsim® Aspen Adsorption Process Modeling(Aspen Plus)

Advanced SimulationOptions

Aspen Batch Plus® Aspen BatchProcess Developer

Process Development ---

Aspen BatchSep™   Aspen BatchDistillation

Process Development Advanced ModelingOptions

Process Modeling(Aspen Plus)

Advanced SimulationOptions

Aspen CatRef® Aspen Plus®Reformer

Aspen Plus BasedRefinery Reactors

---

AspenChromatography®

AspenChromatography®

Process Development Advanced ModelingOptions

Aspen ComThermoWorkbench®

Aspen HYSYS®ThermodynamicsCOM Interface

Process Modeling(HYSYS)

Energy and FlareAnalysis

Aspen CustomModeler®

Aspen CustomModeler®

Process Modeling(Aspen Plus)

Advanced SimulationOptions

Process Modeling Advanced Simulation

Page 16: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 16/214

16 2 Pre-installation

Product NameRelease 2006.5

Product NameV7.0 onwards

Install Mapping(What to Install)

Required InstallOption Selection

(HYSYS) Options

Aspen Dynamics® Aspen Plus®Dynamics

Process Modeling(Aspen Plus)

Advanced SimulationOptions

Aspen FCC® Aspen Plus®CatCracker

Aspen Plus BasedRefinery Reactors

---

Aspen FiredHeater Aspen Fired Heater Exchanger Design andRating

---

Aspen FLARENET™   Aspen Flare SystemAnalyzer

Process Modeling(Aspen Plus)

Energy and FlareAnalysis

Process Modeling(HYSYS)

Energy and FlareAnalysis

Aspen HTFSResearch Network™

Aspen HTFSResearch Network™

Exchanger Design andRating

---

Aspen HX-Net® Aspen EnergyAnalyzer

Process Modeling(Aspen Plus)

Energy and FlareAnalysis

Process Modeling(HYSYS)

Energy and FlareAnalysis

Aspen

Hydrocracker®

Aspen Plus®

Hydrocracker

Aspen Plus Based

Refinery Reactors

---

AspenHydrotreater™

Aspen Plus®Hydrotreater

Aspen Plus BasedRefinery Reactors

---

Aspen HYSYS® Aspen HYSYS® Process Modeling(HYSYS)

---

Aspen HYSYSAmines™

Aspen HYSYSAmines™

Process Modeling(HYSYS)

---

Aspen HYSYSDynamics™

Aspen HYSYSDynamics™

Process Modeling(HYSYS)

---

Aspen HYSYSOLGAS™

Aspen HYSYS®Pipeline Hydraulics- OLGAS 2-Phase

Process Modeling(HYSYS)

---

Aspen HYSYSOLGAS 3-Phase™

Aspen HYSYS®Pipeline Hydraulics- OLGAS 3-Phase

Process Modeling(HYSYS)

---

Aspen HYSYSPIPESYS™

Aspen HYSYS®Pipeline Hydraulics

- PIPESYS

Process Modeling(HYSYS)

---

Aspen HYSYSRTO™ Offline

Aspen HYSYS®Offline Optimizer

Process Modeling(HYSYS)

---

Aspen HYSYS

Upstream™

Aspen HYSYS

Upstream™

Process Modeling

(HYSYS)

---

Aspen HYSYSUpstream

Dynamics™

Aspen HYSYSUpstream

Dynamics™

Process Modeling(HYSYS)

---

Aspen IcarusProcess Evaluator®

Aspen ProcessEconomic Analyzer

Economic Evaluation ---

Aspen IcarusProject Manager®

Aspen In-Plant CostEstimator

Economic Evaluation ---

Page 17: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 17/214

2 Pre-installation 17

Product NameRelease 2006.5

Product NameV7.0 onwards

Install Mapping(What to Install)

Required InstallOption Selection

Aspen Kbase® Aspen Capital CostEstimator

Economic Evaluation ---

Aspen MPIMS™   Aspen MPIMS™   Aspen PIMS ---

Aspen ModelRunner™

Aspen ModelRunner™

Process Modeling(Aspen Plus)

Advanced SimulationOptions

Aspen MUSE™   Aspen MUSE™   Aspen MUSE™   ---

Aspen OnLine® Aspen OnLine® Aspen OnLine® ---

Aspen OnlineDeployment™

Aspen OnlineDeployment™

Operations Support Aspen OnlineDeployment

Aspen PIMS™   Aspen PIMS™   Aspen PIMS ---

Aspen PIMSAdvancedOptimization™

Aspen PIMSAdvancedOptimization™

Aspen PIMS ---

Aspen PIMS

SubmodelCalculator™

Aspen PIMS

SubmodelCalculator™

Aspen PIMS ---

Aspen Plate+™   Aspen PlateExchanger

Exchanger Design andRating

---

Aspen Plus® Aspen Plus® Process Modeling(Aspen Plus)

---

Aspen EO ModelLibrary (Equation-Oriented HYSYS)

Aspen EO ModelLibrary (Equation-Oriented HYSYS)

Process Modeling(HYSYS)

Advanced SimulationOptions

Aspen PlusOptimizer™

Aspen PlusOptimizer™

Process Modeling(Aspen Plus)

---

Process Modeling

(HYSYS)

Advanced Simulation

OptionsAspen PolymersPlus™

Aspen Polymers Process Modeling(Aspen Plus)

---

Aspen ProcessManual™

Aspen ProcessManual™

Aspen ProcessManual™

---

Process Development(Server Install only)

---

Aspen ProcessTools™

Aspen ProcessTools™

Process Development Advanced ModelingOptions

Aspen Properties® Aspen Properties® Process Modeling(Aspen Plus) or

Process Development

---

Aspen RateSep™   Aspen Rate-BasedDistillation

Process Modeling(Aspen Plus)

---

Aspen RefSYS™   Aspen HYSYS®Petroleum Refining

Process Modeling(HYSYS)

Aspen RefSYSCatcracker™

Aspen HYSYS®CatCracker

Process Modeling(HYSYS)

Advanced SimulationOptions

Aspen RefSYSHydrocracker™

Aspen HYSYS®Hydrocracker

Process Modeling(HYSYS)

Advanced SimulationOptions

Page 18: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 18/214

18 2 Pre-installation

Product NameRelease 2006.5

Product NameV7.0 onwards

Install Mapping(What to Install)

Required InstallOption Selection

Aspen RefSYSReformer™

Aspen HYSYS®Reformer

Process Modeling(HYSYS)

Advanced SimulationOptions

Aspen Simulation

Workbook™

Aspen Simulation

Workbook™

Operations Support Aspen Simulation

WorkbookProcess Modeling(Aspen Plus)

Aspen SimulationWorkbook

Process Modeling

(HYSYS)

Aspen Simulation

Workbook

Aspen Split™   Aspen DistillationSynthesis

Process Modeling(Aspen Plus)

---

Aspen Tasc+™   Aspen Shell & TubeExchanger

Exchanger Design AndRating

---

Aspen Teams® Aspen Shell & TubeMechanical

Exchanger Design AndRating

---

Aspen Utilities

Operations™

Aspen Utilities On-

Line Optimizer

Process Modeling

(Aspen Plus)

Advanced Simulation

OptionsAspen UtilitiesPlanner™

Aspen UtilitiesPlanner™

Process Modeling(Aspen Plus)

Advanced SimulationOptions

Aspen Zyqad™   Aspen BasicEngineering

Aspen BasicEngineering

---

NEW (V7.2) Aspen HYSYSDynamics Runtime*

Operations Support

-and-

Process Modeling(HYSYS)

Aspen OTSFramework

NEW (V7.2) Aspen SolubilityModeler

Process Development ---

NEW (V7.1) Aspen Process

DevelopmentConsole

Process Development ---

NEW (V7.0) Aspen ProcessEngineeringConsole

Process Modeling(Aspen Plus and/orHYSYS)

---

New (V7.1) Aspen Plate FinExchanger

Exchanger Design andRating

---

New (V7.0) Aspen ReactionModeler

Process Development Advanced ModelingOptions

Process Modeling(Aspen Plus)

Advanced SimulationOptions

*To install Aspen HYSYS Dynamics Runtime, you must install both Operations

Support | Aspen OTS Framework and Process Modeling (HYSYS).

Page 19: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 19/214

Page 20: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 20/214

20 2 Pre-installation

Option Licensable ProductsInstalled

Sub-Option Licensable ProductsInstalled

Modeling(HYSYS)

  Aspen HYSYSAmines™

  Aspen HYSYS Crude

  Aspen HYSYSDynamics™

  Aspen HYSYS PipelineHydraulics - OLGAS 3-Phase (formerly AspenHYSYS OLGAS 3-Phase)

  Aspen HYSYS PipelineHydraulics - OLGAS 2-Phase (formerly AspenHYSYS OLGAS)

  Aspen HYSYS PipelineHydraulics - PIPESYS(formerly Aspen

HYSYS PIPESYS)   Aspen HYSYS Offline

Optimizer (formerlyAspen RTO Offline)

  Aspen HYSYS

Upstream

  Aspen HYSYSUpstream Dynamics

  Aspen HYSYSPetroleum Refining(formerly AspenRefSYS)

  Aspen HYSYSDynamics Runtime*

  Aspen ProcessEngineering Console

AdvancedSimulationOptions

  Aspen Custom Modeler

  Aspen EO Model Library

  Aspen Properties

  Aspen HYSYS CatCrackerformerly Aspen RefSYSCatCracker)

  Aspen HYSYS Reformer(formerly Aspen RefSYSReformer)

  Aspen HYSYSHydrocracker (formerly

Aspen RefSYSHydrocracker)

  Aspen Plus Optimizer

Energy andFlare Analysis

  Aspen Energy Analyzer(formerly Aspen HX-Net)

  Aspen Flare SystemAnalyzer (formerlyAspen FLARENET)

  Aspen HYSYS

Thermodynamics COM

Page 21: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 21/214

2 Pre-installation 21

Option Licensable ProductsInstalled

Sub-Option Licensable ProductsInstalled

Interface

AspenSimulation

Workbook

  Aspen SimulationWorkbook

ExchangerDesign andRating

  Aspen Air CooledExchanger (formerlyAspen ACOL+)

  Aspen Fired Heater(formerly AspenFiredHeater)

  Aspen Shell and Tube

Exchanger (formerlyAspen TASC+)

  Aspen Shell and TubeMechanical (formerly

Aspen Teams)

  Aspen Plate Exchanger

(formerly AspenPlate+)

  Aspen Plate FinExchanger

  Aspen HTFS ResearchNetwork

AspenProperties

  Aspen Properties

EconomicEvaluation

  Aspen ProcessEconomic Analyzer(formerly Aspen IcarusProcess Evaluator)

  Aspen In-Plant Cost

Estimator (formerlyAspen Icarus ProjectManager)

  Aspen Capital CostEstimator (formerlyAspen Kbase)

ProcessDevelopment

  Aspen Batch ProcessDeveloper (formerlyAspen Batch Plus)

  Aspen Process Manual(server install only)

  Aspen Properties

  Aspen Solubility

Modeler

  Aspen Process

Development Console

AdvancedModelingOptions

  Aspen Chromatography

  Aspen Batch Distillation(formerly AspenBatchSep)

  Aspen Reaction Modeler

  Aspen Process Tools

Basic     Aspen Basic

Page 22: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 22/214

22 2 Pre-installation

Option Licensable ProductsInstalled

Sub-Option Licensable ProductsInstalled

Engineering   Engineering (formerlyAspen Zyqad)

Operations

Support

Aspen Online

Deployment

  Aspen Online

DeploymentAspen OTSFramework

  Aspen OTS Framework**

  Aspen HYSYS DynamicsRuntime*

AspenSimulation

Workbook

  Aspen SimulationWorkbook

AspenOnLine

  Aspen OnLine

Aspen MUSE     Aspen MUSE

Aspen PIMS     Aspen PIMS

  Aspen MPIMS

  Aspen PIMS AdvancedOptimization™

  Aspen PIMS SubmodelCalculator™

Aspen PlusBasedRefineryReactors

  Aspen Plus CatCracker(formerly Aspen FCC)

  Aspen Plus Reformer(formerly AspenCatRef)

  Aspen PlusHydrocracker(formerly AspenHydrocracker)

  Aspen Plus

Hydrotreater (formerlyAspen Hydrotreater)

AspenProcessManual

  Aspen Process Manual

APEDdatabasecomponent

  Aspen Properties

Enterprise Database

AspenPropertiesMobile

  Aspen Properties

Mobile

*To install Aspen HYSYS Dynamics Runtime, you must install both

Operations Support | Aspen OTS Framework  and Process Modeling(HYSYS).

**Aspen OTS Framework is not a product but a component that must beinstalled to run the Aspen HYSYS Dynamics Runtime product.

Page 23: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 23/214

2 Pre-installation 23

Pre-installation ChecklistBefore installing any Aspen Engineering product, review the followingchecklist to ensure a smooth installation.

  Verify that all system requirements are met. For instructions, see

” Checking Aspen System Requirements."   Verify that all additional required software has been installed. For

instructions, see "Checking Software Requirements."

  Verify that all additional product-specific requirements and dependencies

are met. For instructions, see “Checking Product-Specific Requirementsand Dependencies."

  Check which service pack (SP) is installed. For instructions, see "Checking

the Service Pack Version."

  Verify that the virtual memory, including swap space is sufficient for

running Aspen products. For instructions, see “Checking Virtual Memory ."

  Verify that the installation account has local Administrator   privileges. For

instructions, see “Checking Account Privileges."

  Verify that SLM is available. For instructions, see Software LicenseManager (SLM) Installation and Reference Guide,  which is contained the

Documentation DVD.

  Disable any anti-virus software running on your PC so that the installationprogram can copy files to the system area and modify the WindowsRegistry. After you complete the installation, enable the anti-virus

software.

Checking Aspen SystemRequirementsThis section provides the hardware and software requirements for the AspenEngineering products.

Aspen Engineering V7.3 Hardware

RequirementsRequirement Specification

Minimum Requirements   Intel® 1.00GHz or higher

DVD ROM

40 GB

1 GB RAM on XP, 2 GB RAM on VISTA

Recommended   Intel® Core™2 Duo 2.00GHz or higher

DVD ROM

250 GB

3 GB RAM or higher

Disk Space   The programs require about 5 GB when all AspenEngineering functionality is installed. Additionalspace may be required while installing so about 10

Page 24: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 24/214

24 2 Pre-installation

Requirement Specification

GB of free space is recommended. Additionallyprograms generated temporary files that may occupyspace depending on how you use the programs.

Checking SoftwareRequirementsThe following software requirements apply to all Aspen products.

  Internet Explorer 6 SP2 (XP and 2003 Server)

  Internet Explorer 7 (Vista and 2008 Server)

  Internet Explorer 8 (Windows 7, 2008 Server)

  Adobe Reader – see the Adobe website to determine which version is

appropriate for the operating system you are running.

Aspen Engineering V7.3 SoftwareRequirements

Requirement Specification

Operating System Desktop:

Windows XP SP3

Windows Vista Business SP2

Windows Vista Ultimate SP2

Windows 7 Ultimate (32 and 64 Bit)

Windows 7 Professional (32 and 64 Bit)

Server:

Windows Server 2003 R2 Standard SP2 (32-bit)

Windows Server 2003 R2 Enterprise SP2 (32-bit)

Windows Server 2008 Standard R2 (64-bit)

SQL Server   Microsoft SQL Server Express 2005 SP3

Microsoft SQL Server 2005 SP3 (Standard Edition)

Microsoft SQL Server 2005 SP3 (Enterprise Edition)

Microsoft SQL Server 2008 SP1 (Enterprise Edition)

Note: The SQL Server Express 2005 SP3 installationpackage is included on the AspenONE DVD. Thelocation on the disc is:

\3rd Party redistributables\Microsoft SQL

Express 2005 SP3These files are provided for convenience. You shouldseek support from Microsoft if you have installationissues or wish to use other versions of the software.

Microsoft .NET Framework   .NET Framework 3.5 SP 1

Microsoft .NET Framework and SQL Server are prerequisites of the Aspen

Engineering installation. You are responsible for installing this software beforeattempting to install the Aspen Engineering products.

Page 25: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 25/214

2 Pre-installation 25

Certain functionality requires you to install 3rd party programs such as Intel

Fortran, or Visual Studio Compiler, and so on. Details of such 3 rd party

program prerequisites are covered in individual product installation sections

With the exception of Aspen OnLine, all products are supported on English,

German, Japanese, and Chinese versions of the operating systems.

Unsupported language versions of these operating systems may or may notwork and are not tested.

Notes:

  AspenTech continues to support product versions prior to aspenONE V7.3on the operating systems on which they were supported when released

(unless AspenTech has notified customers with an “end of support” dateby e-bulletin and on the AspenTech Support Web site

http://support.aspentech.com/).

  Customers can continue to use products on the operating systems thatwere initially supported by AspenTech (within the limits specified in thelicense agreement).

Checking the Service Pack

Version

To check which Service Pack version is installed

  On the desktop, click  Start | Settings | Control Panel; then double-click

System.

The General  tab of  System Properties  dialog displays the installed versionof Windows and any service pack information.

Checking Virtual MemoryThe recommended amount of virtual memory (physical memory plus swap

file) is 1 Gigabyte. Large plant models or multiple open applications mayrequire additional virtual memory. For information on checking Virtual

Memory, see your Microsoft documentation.

Checking Account PrivilegesWhen installing Aspen products, you must use an account with  LocalAdministrator  privileges. For information on checking Account Privileges,

see your Microsoft documentation.

Page 26: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 26/214

26 2 Pre-installation

Checking Product-SpecificRequirements andDependenciesSome Aspen products have specific pre-installation requirements that must be

met before installing the product.

The following table shows which Aspen products have additional hardwareand/or software requirements and which do not. The additional requirements

are shown below.

This product has additional pre-installationrequirements

Aspen Adsorption V7.3 Yes

Aspen Basic Engineering V7.3 Yes

Aspen Batch Process Developer V7.3 Yes

Aspen Batch Distillation V7.3 No

Aspen Chromatography V7.3 Yes

Aspen Custom Modeler V7.3 Yes

Aspen Distillation Synthesis V7.3 feature inAspen Plus

No

Aspen Economic Evaluation V7.3 Yes

Aspen Energy Analyzer V7.3 No

Aspen Exchanger Design and Rating V7.3

Aspen Shell & Tube Exchanger V7.3

Aspen Air Cooled Exchanger V7.3

Aspen Fired Heater V7.3

Aspen Plate Exchanger V7.3

Aspen Plate Fin Exchanger V7.3

Aspen HTFS Research Network V7.3

Aspen Shell & Tube Mechanical V7.3

Yes

Aspen Flare System Analyzer V7.3 No

Aspen HYSYS V7.3 Yes

Aspen HYSYS Petroleum Refining V7.3 Yes

Aspen HYSYS Upstream V7.3 Yes

Aspen Model Runner V7.3 No

Aspen MUSE V7.3 No

Aspen OnLine V7.3 Yes

Aspen Online Deployment V7.3 Yes

Aspen OTS Framework V7.3 No

Aspen PIMS No

Aspen Plus V7.3 Yes

Aspen Plus CatCracker V7.3 Yes

Aspen Plus Dynamics V7.3 Yes

Aspen Plus Hydrocracker V7.3 Yes

Page 27: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 27/214

2 Pre-installation 27

This product has additional pre-installationrequirements

Aspen Plus Hydrotreater V7.3 Yes

Aspen Plus Reformer V7.3 Yes

Aspen Polymers V7.3 No

Aspen Process Development Console V7.3 No

Aspen Process Engineering Console V7.3 No

Aspen Process Manual V7.3 Yes

Aspen Process Tools V7.3 No

Aspen Properties V7.3 Yes

Aspen Reaction Modeler V7.3 No

Aspen Properties Enterprise Database V7.3 Yes

Aspen Properties Mobile V7.3 Yes

Aspen Remote Simulation Service V7.3 No

Aspen Simulation Workbook V7.3 Yes

Aspen Solubility Modeler V7.3 NoAspen Utilities Planner V7.3 Yes

Aspen Utilities On-Line Optimizer V7.3 Yes

Page 28: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 28/214

28 2 Pre-installation

Aspen Adsorption Additional Requirements

Software Requirements

Requirements Notes

Intel Fortran 9.0, 9.1,10, 10.1,11.0, 11.1, or12.0

Required for customer development of Fortranprocedures.

Note:  Intel Fortran Composer XE 2011 includes IntelFortran 12.0.

Aspen Basic Engineering AdditionalRequirements

Hardware Requirements

64-bit Version of Aspen Basic Engineering Server

Starting from V7.3, Aspen Basic Engineering has a separate DVD containing

the 64-bit installation media. The 64-bit version includes a native 64-bit

Aspen Basic Engineering server as well as the 32-bit client applications. The64-bit Aspen Basic Engineering server is required by customers with very

large workspaces and allows the server process to essentially growunlimitedly (up to 8000 GB) to address as much memory as is available on

the server machine. The 64-bit DVD can be used for server only or standardinstallations on 64-bit operating systems.

For 32-bit operating systems, use the standard aspenONE installation DVD.

Server Hardware

Resource Requirements

CPU 1 GHz minimum (2 to 3 GHz recommended).

The Aspen Basic Engineering Server combined with Oracle

does not perform well on a machine with less than a 1 GHzclock speed. (Oracle or SQL Server is required to run AspenBasic Engineering, see  Software Requirements  below.) Thereare two modes you can use:

Two-tier mode: (RDB Server and Aspen Basic EngineeringServer run on the same host). (Follow the Relational

Database (RDB) product guidelines for additional system

requirements and add these to the overall Server systemrequirements if possible.) The RDB, especially Oracle,combined with the Aspen Basic Engineering Server will notperform well on a machine with less than a 1 GHz clockspeed. At least 2 GHz is recommended.

Three-tier mode: (the RDB exists on a separate PC). TheRDB does not greatly influence the middle tier hosting theAspen Basic Engineering Server other than some additionalmemory to operate its cache on the middle tier. You shoulduse a fast LAN connection between the Aspen Basic

Page 29: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 29/214

2 Pre-installation 29

Engineering Server and RDB Server Aspen Basic EngineeringV7.3 exploits multiple processor server hardware. Addingadditional processors can improve server response times.

Note: AZServer is extremely memory and CPU hungry – werecommend using a modern, fast dedicated machine for theserver.

Physical Memory 2 GB RAM minimum (4 GB recommended)

Note: Large workspaces (for example,1000 equipmentitems) can occupy up to 2 GB of memory each. If the servermachine is being used for multiple large projects, it shouldhave enough physical memory for all workspaces as well asother processes. Rule of thumb:

Physical memory requirement = 2GB + nw x 2GB where nw= the maximum number of workspaces runningsimultaneously.

Hard Disk Space 2 GB (recommended)

DVD Drive

Software Requirements

Component Additional Requirements

Microsoft SQL Server2000 or 2005 SP3 or2008 R2

-or-

Oracle 9i EnterpriseEdition – Version 9.2

Oracle 10g StandardEdition – Version 10.2

One of these Relational Databases is required to run AspenBasic Engineering V7.3 to operate as a transactioned backingstore (the contents of these cannot be designed to be queriedby the user). These products can be installed before or afterinstalling Aspen Basic Engineering. The RDB software can beinstalled either on the Aspen Basic Engineering Server hostmachine, or on a separate machine on the same local area

network.

For Oracle, you must install Oracle OLEDB Client on the Aspen

Basic Engineering Server host machine.

Important Note:  Only a correct and corresponding Oracledriver/client should be used in conjunction with the Oracleserver.Never mix Oracle client/driver versions and server versions

Severe maloperation can result by mixing driver and RDBMSversions from different Oracle installations.

Microsoft Access(optional, not availableon 64-bit operatingsystems)

Note: Aspen Basic Engineering installations can be tested withMicrosoft Access, especially on a Standard install where theserver and client are installed on the same machine. It can beused for some customization work that can be doneindependently of the final deployment environment. MicrosoftAccess must not be used in the deployment of Aspen Basic

Engineering onto engineering projects for reasons of datasecurity in a transactioned environment.

Microsoft Office 2003,

Service Pack 3

-or-

Microsoft Office 2007

-or-

Microsoft Office 2010

Microsoft Excel is required on the client for the Datasheet

Definer and the Excel Datasheet Generator.

Page 30: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 30/214

30 2 Pre-installation

(32-bit only)

Microsoft InternetExplorer 7  -or-

Microsoft InternetExplorer 8

Microsoft IE is required on the client to display KB dialogs

Pro/II v6.0, 6.01, 7.0,

7.1, 8.0, 8.1, 8.2, 8.3

For PRO/II licensees only on the client

HTRI XIST For HTRI licensees only on the client

Aspen Batch Process Developer AdditionalRequirements

Software Requirements

Requirements Notes

Aspen Plus V7.3   and Aspen Plus DynamicsV7.3

Required to run Kinetic Reactor model.

Microsoft Project 2003or 2007

Required to view Project charts.

Visio Professional 2003or 2007

Required to view Block and Equipment diagrams.

2007 CompatibilityPack

Required if using Excel 2003.

Aspen Chromatography Additional Software

RequirementsResource Requirements

Intel Fortran 9.0, 9.1,10, 10.1,11.0, 11.1, or12.0.

Required for customer development of Fortran procedures.

Note:  Intel Fortran Composer XE 2011 includes Intel Fortran12.0.

Aspen Custom Modeler Additional SoftwareRequirements

Requirements Notes

Intel Fortran 9.0, 9.1,10, 10.1,11.0, 11.1, or12.0.

Required for customer development of Fortran procedures.

Note:   Intel Fortran Composer XE 2011 includes Intel Fortran12.0.

Note: The compiler must be configured so that it can beused from the command line.

If multiple versions of the compiler are installed, by

default the most recent version is used.

Page 31: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 31/214

2 Pre-installation 31

Microsoft Visual C++2008

Required for customer development of C/C++ procedures, orto export models for use in Aspen Plus or HYSYS.

Microsoft Visual Basic

.NET 2008

Required to create custom forms within Aspen Custom

Modeler.

Aspen Economic Evaluation AdditionalRequirementsRequirements Notes

Internet Explorer 6.0 orhigher

Required for certain reports in all Aspen Economic Evaluationproducts.

Microsoft Excel 2003 orlater

Required for Aspen Decision Analyzer and certain reports inall other Aspen Economic Evaluation products.

Primavera EnterpriseProject Manager (P3e),Primavera IntegrationAPI, and Java Runtime

Environment or JavaDevelopment kit.

Required for scheduling component of Aspen Icarus ProjectScheduler (IPS) and Aspen In-Plant Cost Estimator (AICE).P3e, the Primavera Integration API, and Java componentsmust be installed and configured prior to successful operation

of IPS and AICE. For further information, see relatedPrimavera installation documents and the Aspen Capital CostEstimator and Aspen In-Plant Cost Estimator User Guideswhich provide an installation/configuration checklist.

Primavera ProjectPlanner for Windows(P3) 3.1

Required for legacy scheduling component of Aspen In-PlantCost Estimator. P3 must be installed prior to installing AspenIn-Plant Cost Estimator. For instructions, see the  PrimaveraProject Planner for Windows Reference   (version 3.0), pagesxxii-xxxiii, “Setting up P3.” 

Aspen Exchanger Design and Rating

Additional RequirementsRequirements Notes

Microsoft Excel 2003 orlater

Required for Microsoft Excel reports in all Aspen ExchangerDesign and Rating products.

Microsoft .NETFramework 3.5 SP1

Prerequisite for all Aspen Engineering Suite products.

Microsoft SQL

Express 2005 SP3Required for Aspen Properties..

Aspen HYSYS Additional Software

RequirementsRequirements Notes

Aspen ExchangerDesign and Rating V7.3

Required for detailed heat exchanger analysis.

Aspen EconomicEvaluation V7.3

Required to perform Capital Cost Estimation calculations.

Page 32: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 32/214

32 2 Pre-installation

Aspen HYSYS Petroleum RefiningAdditional Software RequirementsRequirements Notes

CrudeManager RefSYS

Link LE orCrudeManager RefSYSLink

This feature lets you import assays from a special version of 

CrudeManager - the assay management system from SpiralSoftware Ltd.

Aspen PIMS Required to share CME (Common Model Environment) sub-models.

Aspen PetroleumRefinery Scheduler

Required to share CME (Common Model Environment) sub-models.

Aspen HYSYS Upstream AdditionalSoftware RequirementsRequirements Notes

Prosper GAP Required to run GAP unit operation

PIPESIM 2003 orhigher

PIPESIM 2003 or higher is required for the PIPESIM Link andPIPESIM Net unit operations.

OLGA from SPT Group Required to run the HYSYS OLGA link

Infochem Multiflashversion 3.8

Required to create infochem multi-flash property packagesand infochem multiflash reservoir fluids in the HYSYS PVTenvironment.

Aspen OnLine Additional SoftwareRequirementsRequirements Notes

Microsoft IIS 5 Required to install Aspen OnLine. One of the Microsoftcomponents used by Aspen OnLine has a dependency on IIS

5.

Aspen Plus V7.3 Required if the model driven by Aspen OnLine is an Aspen Plussimulation model.

A complete installation of the Aspen Plus application should beinstalled on the computer running Aspen OnLine Server.

Aspen Custom ModelerV7.3

Aspen Adsorption V7.3

Aspen ChromatographyV7.3

For a model to be driven by Aspen OnLine, the successfulinstallation of the corresponding product and application onthe computer running Aspen OnLine Server is required.

CIM-IO Server CIM-IO server must be available to serve data residing on theDCS or information management system like InfoPlus 21,PHD, or PI.

Note: CIM-IO client component is installed automatically with

Aspen OnLine (standard install) when the server component isselected.

Page 33: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 33/214

2 Pre-installation 33

Microsoft Excel 2000 orhigher

Required by both Aspen OnLine Server and Client GUI.

Microsoft Access 2000

or higher

Optional

Aspen Process Explorer Optional (Tag browser can be used together with AspenOnLine to easily add tags)

Aspen Online Deployment AdditionalSoftware RequirementsRequirement Notes

Aspen HYSYS V7.0,V7.1, V7.2, V7.3

HYSYS is needed to run HYSYS simulation cases online.

HYSYS MUST be installed on any system that uses Aspen

Online Deployment to create and maintain HYSYS-basedAspen Online Deployment online applications.

HYSYS must be installed on any system that solves the AspenHYSYS cases on behalf of an online application (this could bethe system running the Online Deployment online server, or itcould be a system running the Aspen Remote SimulationService).

Aspen Plus V7.0,V7.1, V7.2, V7.3

Aspen Plus is needed to run Aspen Plus simulation casesonline.

Aspen Plus MUST be installed on any system that uses AspenOnline Deployment to create and maintain Aspen Plus-basedAspen Online Deployment online applications.

Aspen Plus must be installed on any system that solves theAspen Plus cases on behalf of an online application (this could

be the system running the Online Deployment online server,or it could be a system running the Aspen Remote SimulationService).

Aspen Model RunnerV7.1, V7.2, V7.3

Aspen Model Runner is needed to run Aspen Model Runnersimulation cases online.

Aspen Model Runner MUST be installed on any system thatuses Aspen Online Deployment to create and maintain AspenPlus-based Aspen Online Deployment online applications.

Aspen Model Runner must be installed on any system thatsolves the Aspen Model Runner cases on behalf of an onlineapplication (this could be the system running the OnlineDeployment online server, or it could be a system running theAspen Remote Simulation Service).

Aspen CustomModeler V7.0, V7.1,V7.2, V7.3

Aspen Custom Modeler is needed to run Aspen CustomModeler simulation cases online.

Aspen Custom Modeler MUST be installed on any system thatuses Aspen Online Deployment to create and maintain AspenCustom Modeler-based Aspen Online Deployment onlineapplications.

Page 34: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 34/214

34 2 Pre-installation

Aspen Custom Modeler must be installed on any system thatsolves the Aspen Custom Modeler cases on behalf of an onlineapplication (this could be the system running the OnlineDeployment online server, or it could be a system running theAspen Remote Simulation Service).

Aspen ExchangerDesign and Rating

V7.0, V7.1, V7.2,V7.3

Aspen Exchanger Design and Rating is needed to runExchanger Design and Rating simulation cases online.

Aspen Online Deployment t can execute Aspen Shell & TubeExchanger (Tasc+), Aspen Air Cooled Exchanger (Acol+),Aspen Plate Exchanger (Plate+) and Aspen Fired Heater(FiredHeater) models online. The exchanger design and ratingfile (EDR file) must contain only one heat exchangerdefinition.

Exchanger Design and Rating MUST be installed on anysystem that uses Aspen Online Deployment to create andmaintain Exchanger Design and Rating based Aspen OnlineDeployment online applications.

Exchanger Design and Rating must be installed on any system

that solves the Exchanger Design and Rating cases on behalf of an online application (this could be the system running theOnline Deployment online server, or it could be a systemrunning the Aspen Remote Simulation Service).

Aspen RemoteSimulation ServiceV7.3

Aspen Remote Simulation Service must be installed on aserver computer that will solve HYSYS, Aspen Plus, ExchangerDesign and Rating, or Aspen Custom Modeler models onbehalf of Aspen Online Deployment applications running onthe same or a different server computer.

Note:   Aspen Remote Simulation Service gets installed whenAspen Simulation Workbook or Aspen Online Deployment areinstalled on a system; it cannot be installed directly.

Aspen CIM-IO V7.3(on the AspenManufacturing SuiteDVD)

Aspen CIM-IO is required on the server computer hostingAspen Online Deployment online applications. It is notrequired on a computer that will only run the Aspen OnlineDeployment Desktop.

Aspen Process Data

V7.3 (on the AspenManufacturing SuiteDVD)

Aspen Process Data is required on the server computer

hosting Aspen Online Deployment online applications. It is notrequired on a computer that will only run the Aspen OnlineDeployment Desktop.

Aspen Data SourceArchitecture V7.3 (onthe AspenManufacturing SuiteDVD)

Aspen Online Deployment will only use Process Data sourcesconfigured on a public ADSA data source directory server. If you do not already have an ADSA directory server that youplan to use, then you must install one and configure theAspen Online Deployment online application server to use it.

Aspen APC Web

Server V7.3 (on theAspen ManufacturingSuite DVD)

Aspen APC Web Server is required to be installed on a web

server to manage, view, and interact with Aspen OnlineDeployment online applications.

Aspen Local SecurityV7.3 (on the AspenManufacturing SuiteDVD) or AspenFramework Server

The Aspen Online Deployment online application server andAspen APC Web Server use Aspen Framework (AFW) Securityto provide role-based authorization of access to the onlineapplications. You must either configure the online applicationserver and web server systems to use an existing AFWSecurity server, or you must install one. You can either installAspen Local Security or an Aspen Framework Server.

Page 35: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 35/214

2 Pre-installation 35

Aspen Plus Additional SoftwareRequirementsRequirements Notes

Intel Fortran

9/10/11/12 Standardor Professional, with alinker

Required for customer development of Fortran models. Linker

may be:   Microsoft Visual Studio 2003, 2005 or 2008; or

  Microsoft Visual C++ Express 2005, 2008; or

  Bundled Visual Studio or Visual Studio 2010 for IntelFortran 11.1 or later.

Note:  Intel Fortran Composer XE 2011 includes Intel Fortran12.0.

It is also possible to use Compaq Visual Fortran (6.6a) withsome limitations. See  Aspen Plus User Models   for details.

Microsoft SQL Server2005 or 2008, orMicrosoft SQL Express2005, and a non-

compressed drive forstoring SQL databases.

Required if Aspen Properties Enterprise Database is installedlocally.SQL Server or SQL Express must be configured to use  SQLServer and Windows   authentication mode. See Configuring

Microsoft SQL Server or SQL Express

Aspen Plus no longer uses Microsoft SQL Server DesktopEdition (MSDE) or SQL Server 2000, due to problemsencountered with these SQL servers.

FactSage 5.1 or later Used to generate ChemSage files for the ChemApp interface;need not be on the same computer with Aspen Plus.

ChemApp 5.3.2 orlater

Required to use FACT/ChemApp interface for pyrometallurgicalprocesses.

Aspen ExchangerDesign and RatingV7.3

Required for detailed heat exchanger analysis.

Macromedia/Adobe

Flash Player 5 or later

Required to view the viewlets in online help. If you do not have

Flash Player installed, visithttp://www.macromedia.com/go/getflashplayer to install it.

Aspen EconomicEvaluation V7.3

Required to perform Capital Cost Estimation calculations.

Windows XPProfessional

Required for Aspen OLI Interface

Note: When you install Aspen Plus, the separately licensed Aspen PlusOptimizer is installed automatically.

Aspen Plus CatCracker Additional Software

RequirementsRequirements Notes

Aspen Plus V7.3 Required to run Aspen Plus CatCracker. Aspen Plus CatCrackeris not compatible with concurrent installations of multipleversions of itself or Aspen Plus.

Page 36: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 36/214

36 2 Pre-installation

Aspen Plus Dynamics Additional SoftwareRequirementsRequirements Notes

Intel Fortran 9.0, 9.1,

10.0, 10.1, 11.0, 11.1,or 12.0

Required for customer development of Fortran procedures.

Note:   Intel Fortran Composer XE 2011 includes Intel Fortran12.0.

Microsoft Visual C++2008

Required for customer development of C/C++ procedures, orto export models for use in Aspen Plus or HYSYS.

Microsoft Visual Basic.NET 2008

Required to create custom forms within Aspen CustomModeler.

Aspen Plus Hydrocracker Additional

Software RequirementsRequirements Notes

Aspen Plus V7.3 Required to run Aspen Plus Hydrocracker. Aspen Plus

Hydrocracker is not compatible with concurrent installations of multiple versions of itself or Aspen Plus.

Aspen Plus Hydrotreater AdditionalSoftware RequirementsRequirements Notes

Aspen Plus V7.3 Required to run Aspen Plus Hydrotreater. Aspen PlusHydrotreater is not compatible with concurrent installations of multiple versions of itself or Aspen Plus.

Aspen Plus Reformer Additional Software

RequirementsRequirements Notes

Aspen Plus V7.3 Required to run Aspen Plus Reformer. Aspen Plus Reformer isnot compatible with concurrent installations of multipleversions of itself or Aspen Plus.

Aspen Process Manual AdditionalRequirements

For Aspen Process Manual Server:

Hardware

Requirements Notes

Page 37: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 37/214

2 Pre-installation 37

Hard Disk Space Up to 1.2GB free disk space, depending upon the number of technical areas installed

Software

Requirements Notes

Internet InformationServer (IIS)

Required to run the product; must be installed first.

ASP Required to run the product; must be installed first.

For Aspen Process Manual Client:

Software

Requirements Notes

Internet Explorer 5 or

Later

Client must be configured to allow session cookies.

Java Virtual Machine Client must be configured to allow session cookies.

Active X Controls Some content uses signed Active X controls; these may bedisabled for the application, but functionality will be reduced.

Adobe Acrobat Reader Required for some content

Other Browsers May work, provided they have support for JavaScript.

Aspen Properties Additional SoftwareRequirementsRequirements Notes

Intel Fortran9/10/11/12 Standardor Professional, with alinker

Required for customer development of Fortran models. Linkermay be:

  Microsoft Visual Studio 2003, 2005 or 2008; or

  Microsoft Visual C++ Express 2005, 2008; or

  Bundled Visual Studio or Visual Studio 2010 for IntelFortran 11.1 or later.

Note:  Intel Fortran Composer XE 2011 includes Intel Fortran12.0.

It is also possible to use Compaq Visual Fortran (6.6a) withsome limitations. See  Aspen Plus User Models   for details.

Microsoft SQL Server2005 or 2008, or

Microsoft SQL Express2005, and a non-compressed drive forstoring SQL databases.

Required if Aspen Properties Enterprise Database is installedlocally.

SQL Server or SQL Express must be configured to use  SQLServer and Windows   authentication mode. See  ConfiguringMicrosoft SQL Server or SQL Express

.

Aspen Properties no longer uses Microsoft SQL Server DesktopEdition (MSDE), due to numerous problems encountered withthis SQL server.

MDAC 2.8 SP1 or later Required before Microsoft SQL Express can be installed.

Page 38: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 38/214

38 2 Pre-installation

Aspen Properties Enterprise DatabaseAdditional Software RequirementsRequirements Notes

Microsoft SQL Server

2005 or 2008, orMicrosoft SQL Express2005, and a non-compressed drive forstoring SQL databases.

SQL Server or SQL Express must be configured to use  SQL

Server and Windows   authentication mode. See  ConfiguringMicrosoft SQL Server or SQL Express.

Aspen Properties Enterprise Database no longer uses MicrosoftSQL Server Desktop Edition (MSDE), due to numerousproblems encountered with this SQL server.

Aspen Properties Mobile AdditionalSoftware RequirementsRequirements Notes

Internet Information

Server (IIS)Server certificateinstalled on IIS

Required to use secure communication (https).

Aspen Properties V7.1or later

The version of Aspen Properties intended to be used withAspen Properties Mobile must already be installed beforeAspen Properties Mobile is installed.

Aspen PropertiesMobile app available onthe App StoreSM

For iPad™, iPhone® 4, iPhone® 3GS, iPhone® 3G, the originaliPhone®, or iPod® touch. iOS versions 3 and 4 are supported.

Aspen Simulation Workbook Additional

Software RequirementsRequirements Notes

Microsoft Excel 2003 orlater

Required to use the Aspen Simulation Workbook.

If using Excel 2003, Microsoft KB 907417 is required.

Aspen Plus V7.0, V7.1or V7.3

Aspen HYSYS V7.0,V7.1 or V7.3

Aspen Custom ModelerV7.0 V7.1 or V7.3

Aspen Plus Dynamics

V7.1 or V7.3Aspen ChromatographyV7.1 or V7.3

Aspen Adsorption V7.1or V7.3

Aspen ExchangerDesign and RatingV7.0, V7.1 or V7.3

Required to use models from these products within the AspenSimulation Workbook.

Page 39: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 39/214

2 Pre-installation 39

Aspen Utilities Planner Additional SoftwareRequirementsRequirements Notes

Microsoft Excel 2003 or

2007

Used for reports. If using Excel 2003, Microsoft KB 907417 is

required.Microsoft Access 2003,2007

One of these databases is required to run Aspen UtilitiesPlanner and Aspen Utilities On-Line Optimizer.

Aspen Utilities On-Line Optimizer

Additional Software RequirementsRequirements Notes

Aspen Online Required to connect Aspen Utilities Planner to online data andto control execution of Aspen Utilities Planner

CIM-IO Used to transfer data between AspenTech products and

external devices.

Microsoft Excel 2003 or2007

Used for reports.

Microsoft Access 2003or 2007

One of these databases is required to run Aspen UtilitiesPlanner and Aspen Utilities On-Line Optimizer.

Recommended InstallationSequence

Before you begin to install any Aspen Engineering software, we recommendthat the SLM Server is installed, configured, and available. This is typicallydone by your System Administrator.

Note: Normally you need to install SLM (Software License Manager) products

before installing Aspen applications. For information on how to install SLM(Software License Manager) products, see   Software License Manager (SLM)

Installation and Reference Guide, which is on the  Documentation  DVD.

Page 40: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 40/214

40 2 Pre-installation

Page 41: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 41/214

3 Installing Aspen Products 41

3 Installing Aspen Products

OverviewThis Guide covers installation of Aspen Engineering products when installed by

clicking the  Products  tab on the Installation Browser.

SLM Client ToolsWhen installing the Aspen Engineering products, you can also install the SLM

(Software License Manager) Client Tools. For information about these SLMclient tools, see   Software License Manager (SLM) Installation and ReferenceGuide.

Installing Aspen ProductsThis version of the Aspen Engineering Application Products is contained onDVD 1,   Aspen Engineering.

Note: If you are prompted to do so, restart your computer at the end of the

installation.Note: The installation program will check for all pre-requisites; if the pre-

requisite software is not present on the computer on which you are installing

Aspen software, you will get an error message and the installation will notproceed.

Important Installation Changefor V7.3With Aspen Engineering Suite V7.3, there are two options for installing AspenEngineering Products.

If you are installing:

o   Aspen Exchanger Design and Rating V7.3.1

o   Aspen Economic Evaluation V7.3.1

Page 42: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 42/214

42 3 Installing Aspen Products

o   Aspen Properties Mobile V7.3

  Click  Products | Aspen Engineering (for Upgrade) | Install.

If you are installing any other product:

  Click  Products | Aspen Engineering | Install.

Installation OptionsThere are two options for installing Aspen Engineering products:

  The Standard  option installs all files to the local hard drive of a computer.The computer can be a stand-alone or network PC with enough space and

power on the local drive to store and run the installed products.

For details, see “Standard Installation.” 

  The Server  option installs files on a central server machine. Products

supporting this configuration usually put computing intensive or main data

processing activities on the server machine.

For details, see "Client-Server Installation."

Note:   Not all products have both options.

Valid Aspen Product Installation Options

The following table summarizes the valid installation options for each Aspenproduct.

Aspen Product Installation Options

Standard Server

Aspen Adsorption V7.3 Yes YesAspen Basic Engineering V7.3 Yes Yes

Aspen Batch Distillation V7.3 Yes No

Aspen Batch Process Developer V7.3 Yes No

Aspen Chromatography V7.3 Yes Yes

Aspen Custom Modeler V7.3 Yes Yes

Aspen Economic Evaluation V7.3 Yes Yes

Aspen Energy Analyzer V7.3 Yes No

Aspen Exchanger Design and Rating V7.3

Aspen Shell & Tube Exchanger V7.3

Aspen Air Cooled Exchanger V7.3

Aspen Fired Heater V7.3

Aspen Plate Exchanger V7.3

Aspen Plate Fin Exchanger V7.3

Aspen Shell & Tube Mechanical V7.3

Aspen HTFS Research Network V7.3

Yes Yes

Aspen Flare System Analyzer V7.3 Yes No

Aspen HYSYS V7.3 Yes Yes

Aspen HYSYS Refining V7.3 Yes No

Page 43: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 43/214

3 Installing Aspen Products 43

Aspen Product Installation Options

Standard Server

Aspen HYSYS Upstream V7.3 Yes Yes

Aspen Model Runner V7.3 Yes Yes

Aspen MUSE V7.3 Yes YesAspen OnLine V7.3 Yes Yes

Aspen Online Deployment V7.3

Note: If HYSYS, Aspen Plus, or ACM areinstalled in order to support Aspen OnlineDeployment, then those products  MUST  beinstalled with the  Standard  option or all therequired features will not be installed.

Yes Yes

Aspen OTS Framework V7.3 Yes No

Aspen PIMS V7.3 Yes Yes

Aspen Plus V7.3 Yes No

Aspen Plus CatCracker V7.3 Yes No

Aspen Plus Dynamics V7.3 Yes Yes

Aspen Plus Hydrocracker V7.3 Yes No

Aspen Plus Hydrotreater V7.3 Yes No

Aspen Plus Reformer V7.3 Yes No

Aspen Polymers V7.3 Yes No

Aspen Process Development Console V7.3 Yes No

Aspen Process Engineering Console V7.3 Yes No

Aspen Process Manual V7.3 No Yes

Aspen Process Tools V7.3 Yes No

Aspen Properties V7.3 Yes No

Aspen Properties Enterprise Database V7.3 Yes Yes

Aspen Properties Mobile V7.3 No Yes

Aspen Reaction Modeler V7.3 Yes No

Aspen Remote Simulation Service V7.3 Yes Yes

Aspen Simulation Workbook V7.3 Yes Yes

Aspen Utilities On-Line Optimizer Yes No

Aspen Utilities Planner V7.3 Yes No

Note: Aspen Basic Engineering is normally installed in a client-server

configuration for project deployment.

Note: An option to install the Aspen Properties Enterprise Databasecomponent without installing Aspen Properties or another product which uses

it is available only in the server installation.Important: For Aspen Modeler products (Aspen Adsorption, Aspen BatchDistillation, Aspen Chromatography, Aspen Custom Modeler, Aspen ModelRunner, Aspen Plus Dynamics, and Aspen Reaction Modeler), V7.3 is the last

version of aspenONE that will offer the server installation option.

Page 44: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 44/214

44 3 Installing Aspen Products

Standard InstallationThis section explains how to install Aspen Engineering products for the firsttime by using the  Standard   installation option. The  Standard   option installsAspen product components on a single computer.

Note: If this is NOT your first time using the Standard installation, or if youare upgrading an Aspen product, Chapter 6 “ Adding and Upgrading Aspen

Products."

Before You Begin

See the “Pre-installation Checklist” section before you begin the installation.

If you are installing any of these products, review the installation notes in

their product sections in addition to the installation procedures in this section.

If you areinstalling

see

Aspen BasicEngineering

Aspen Basic Engineering Installation Notes

Aspen Batch ProcessDeveloper

Aspen Batch Process Developer Installation Notes

Aspen EconomicEvaluation

Aspen Economic Evaluation Installation Notes

Aspen ExchangerDesign and Rating

Aspen Exchanger Design and Rating Installation Notes

Aspen HYSYS Aspen HYSYS Installation Notes

Aspen OnLine Aspen OnLine Installation Notes

Aspen Online

Deployment

Aspen Online Deployment Installation Notes

Aspen Plus Aspen Plus Installation Notes

Aspen Process

Manual

Aspen Process Manual Installation Notes

Aspen Properties Aspen Plus Installation Notes

Aspen PropertiesEnterprise Database

Aspen Plus Installation Notes

Aspen RemoteSimulation Service

Aspen Remote Simulation Service Installation Notes

Aspen SimulationWorkbook

Aspen Simulation Workbook Installation Notes

Aspen Utilities On-

Line Optimizer

Aspen Utilities On-Line Optimizer Installation Notes

Aspen UtilitiesPlanner

Aspen Utilities Planner Installation Notes

Page 45: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 45/214

3 Installing Aspen Products 45

Standard Installation Using the AspenEngineering DVD

To perform a Standard installation of Aspen Engineering products

1   Log on to the computer, using an account with Local Administratorprivileges.

2   Insert the Aspen Engineering  DVD (DVD 1) into the DVD drive.

Note: If the installation does not start automatically, click  Start | Run. In

the  Run dialog box, enter  <drive>:\setup (where  <drive>   is the drive

letter assigned to your DVD drive); then click  OK.

The  AspenTech DVD Browser  window appears.

3   Click the Products  tab.

Note: If you want to see only products that you are licensed to install, selectthe   Show Licensed Products Only  check box.

A license requirement dialog box appears.

4   Click  OK.

Page 46: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 46/214

46 3 Installing Aspen Products

The License Configuration  Wizard appears.

Note: If you are installing the SLM Server, see   Software License Manager (SLM) Installation and Reference Guide,  which is contained on the

Documentation  DVD.

5 Click Next.

The License Configuration Type   dialog box appears.

6   Accept the default  Both  option and click  Next.

Note: You can click  None. If you click  None, skip to Step 10 below.

Page 47: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 47/214

3 Installing Aspen Products 47

The  License Files   dialog box appears..

7   Do the following:

o   If you have one or more standalone license files that are local to yourcomputer, click  Add License File, and then use the  Open  dialog box

to locate the license files (*.lic,  *.slf ). Then click  Next.

-and/or-

o   If you have licenses that are obtained from a network license server,

click  Next.

The License Servers  dialog box appears.

8   In the License Servers  dialog box, enter the  License Server  name and

click  Add Server, and repeat until all applicable  License Server  namesare included in the list. Then click  Next.

Page 48: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 48/214

48 3 Installing Aspen Products

The Determining Product Licenses   dialog box appears.

9   After the Licenses  list is populated with all licenses found, click  Next.

10  Click one of the following two options:

If you are installing:

o   Aspen Exchanger Design and Rating V7.3.1

o   Aspen Economic Evaluation V7.3.1

  Click  Products | Aspen Engineering (for Upgrade) | Install.

If you are installing any other product:

  Click  Products | Aspen Engineering | Install.

The Windows Installer  view appears briefly as it prepares for installation.

One of the following  AspenTech Installer  dialogs appears.

This version of the Aspen Installer dialog appears when no aspenONEproducts are installed:

Page 49: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 49/214

3 Installing Aspen Products 49

This version appears when one or more aspenONE   products are installed:

11   Whichever screen appears, click  Next   to continue.

Page 50: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 50/214

50 3 Installing Aspen Products

The License Agreement dialog box appears.

12  Review the license agreement. If you accept this agreement, click  Yes, I

accept the terms in the license agreement. If you do not accept it,click  No, I do not accept the terms in the license agreement.  If youclick on  No, you will not be able to continue with the installation.

Note: If you have already installed one or more aspenONE products, the next

screen will be the  Program Maintenance  screen.

Page 51: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 51/214

3 Installing Aspen Products 51

If you want to install additional programs or remove some (but not all)

existing Aspen programs:

o   Click  Modify; then click  Next. Skip to Step 14 below.

The Computer Configuration Type  dialog box appears.

13  Click  Standard Install  to install the Aspen software on a singlecomputer.

The Choose Destination Location   dialog box appears.

Page 52: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 52/214

52 3 Installing Aspen Products

14  To specify a different folder, click  Browse, then navigate to the correct

folder. When you are satisfied with the installation folder (default or your

choice), click  Next.

The Feature Selection   dialog box appears.

15  On the  Feature Selection  dialog box, click the Aspen product(s) you

want to install on the computer by clicking on the tree of products andproduct features. Click the  PLUS SIGN  and   MINUS SIGN  symbols to display or

hide branches of the tree. For each feature, you can select options thatcontrol the installation.

Initially, the icons appear with the red “x”. Open a tree and the icon there

will also have a red “x”. When you click on the subfeature “x” icon, thefollowing menu appears:

16  On this menu, select how you want that program to be installed.

Note: For an explanation of the icons, click  Help.

Changing Product/Subfeature Folders

For a selected product, you can change the default destination location of itsproduct directory. For some features you can also change the default

destination folder of product subfeatures.

To change the destination location of a selected Aspen product orsubfeature

A  On the  Feature Selection  dialog box, click   Change.

Page 53: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 53/214

3 Installing Aspen Products 53

The  Change Current Destination Location  dialog box appears.

The default destination is:

C:\Program Files\AspenTech

B  On the  Change Current Destination Location  dialog box, either

o   browse to the directory that you want to specify as the rootdestination directory under which all AspenTech products for

this software version  will be installed  on this computer . (If adialog box appears prompting you for permission to create the

folder, click  Yes.).

-or-

o   in the Folder name  field, type the path to the directory that

you want to specify as the root destination directory underwhich all AspenTech products for   this software version  will be

installed  on this computer . (If a dialog box appears prompting

you for permission to create the folder, click  Yes.).

Note: Once the installation of any Aspen product has been completed for

this software version on this computer, you cannot change the location of 

the AspenTech folder.Note the following product restrictions:

Product Restriction

AspenEconomicEvaluation

The Aspen Economic Evaluation product directory must be installedno deeper than the third level of the directory structure. Forexample: D:\Program Files\AspenTech\Aspen EconomicEvaluation V7.3

Page 54: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 54/214

54 3 Installing Aspen Products

C  Click  OK.

You are returned to the  Feature Selection   dialog box.

17   This screen may appear regarding pre-requisites:

If it appears, click  Report  to get detailed instructions on the products

required, with links to download and configuration instructions. Then:

o   You should download all the required products first, since some

installations may require reboots.

o   You should print the page you get with  Report   for reference.

o   If any of the prerequisites is marked  Exiting AspenTech Installer

Required, you should exit the installer by clicking  Exit.

When you are done installing the prerequisites, if you did not have to exitthe installer, click  Recheck. If you did have to exit the installer, restart

the Aspen Engineering installation, if necessary. When doing so, when this

message appears, click  Yes.

Then the various screens starting with  Welcome  screen will appear. ClickNext  (and  Yes  on the  License Agreement  screen) to get through them.Your selections on the  Feature Selection  screen will be preserved. If you

have satisfied all the pre-requisites, the  Prerequisite Validation   screenwill not reappear.

Page 55: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 55/214

3 Installing Aspen Products 55

18  If this is the first installation of Aspen products on your computer, you are

prompted to choose a Working File Folders location.

19  Select a folder; then click  Next.

20  Click  Next  to continue.

Configuring Aspen Products at Install TimeDepending on the products you are installing, additional dialog boxes mayappear, prompting you for product-specific information.

If you are installing you are prompted for

Aspen Basic Engineering If the  Aspen Basic Engineering Brokerwindow appears, see Aspen Basic EngineeringInstallation Notes."

Aspen OnLine DCOM user account, and CIM-IO core security

settings. For details, see "Aspen OnLine."

If you install Aspen Remote Simulation Service, you are prompted for the

username and password of an account which will be used to run this service.

Page 56: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 56/214

56 3 Installing Aspen Products

When you install the Aspen Properties Enterprise Database feature of any

product and just one instance of MS SQL Server 2005 or 2008 or MS SQLServer Express 2005 is installed on the computer, it will be used. If more than

one such SQL server instance is installed, the installer will ask which one to

use.

Page 57: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 57/214

3 Installing Aspen Products 57

If you are installing Aspen Plus or Aspen Properties, you will be prompted to

configure the Fortran compiler. If no Fortran compiler is installed, the dialog

box will appear as shown below with the choices set to User and dimmed. If one or more compilers are installed, you will be able to choose the Fortrancompiler to use.

Ready to Install21  Click  Next  until the  Ready to Install the Program  dialog box appears.

Page 58: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 58/214

58 3 Installing Aspen Products

22  Review your selected installation options. (To modify any selected option,click  Back  to navigate to the appropriate dialog box and make thechanges.)

23  To complete the installation, click  Install.

24  Wait as the installation begins. The  Installing Aspen Engineeringscreen appears on which you can monitor the progress of the installation.

Setup Complete

Once the installation is finished, the  Wizard Completed  dialog box appears.

Page 59: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 59/214

3 Installing Aspen Products 59

25  Click  Finish.

26  A message box appears asking you to restart your computer. Do either of 

the following:

o   Click  Yes to restart your computer right away.  The systemshuts down and reboots.

o   Click  No to restart it later.

27  When the system reboot is complete, log on to Windows using an accountwith local Administrator privileges.

Client-Server Installation

Overview

This section provides instructions for installing Aspen products in a client-

server installation configuration.

Note: Only system administrators should perform this type of installation.

A server installation of Aspen products takes advantage of using a powerfulserver computer to perform calculations and various data- processing

activities. The following Aspen products support the Server installation option:

  Aspen Adsorption V7.3

  Aspen Basic Engineering V7.3

  Aspen Chromatography V7.3

Page 60: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 60/214

60 3 Installing Aspen Products

  Aspen Custom Modeler V7.3

  Aspen Economic Evaluation V7.3

  Aspen Exchanger Design and Rating V7.3

  Aspen HYSYS V7.3

  Aspen HYSYS for Upstream V7.3

  Aspen Model Runner V7.3

  Aspen MUSE V7.3

  Aspen OnLine V7.3

  Aspen Online Deployment V7.3

  Aspen PIMS V7.3

  Aspen Plus Dynamics V7.3

  Aspen Process Manual V7.3

  Aspen Properties Mobile V7.3

  Aspen Remote Simulation Service V7.3

  Aspen Simulation Workbook V7.3

Before You Begin

Before you begin the installation process:

  Review the “Pre-installation Checklist" section.

  Because several users may be running a calculation engine on the serversimultaneously, ensure the server machine has appropriate resources. For

guidelines, see "Checking Aspen System Requirements."

  Ensure the server and client machines use TCP/IP communication andhave the appropriate network access in both directions.

  Ensure the server and the user PCs have the proper name resolution

present so that the user PCs recognize the server name entered at runtime.

  Ensure that the users of Aspen products have Windows accounts that are

valid on the application server.

  If you are installing any of these products, review the installation notes inthe appropriate product section, in addition to the installation procedures

in this section.

If you areinstalling

see

Aspen BasicEngineering

Aspen Basic Engineering Installation Notes

Aspen EconomicEvaluation Aspen Economic Evaluation Installation Notes

Aspen HYSYS Aspen HYSYS Installation Notes

Aspen OnLine Aspen OnLine Installation Notes

Aspen OnlineDeployment

Aspen Online Deployment Installation Notes

Aspen ProcessManual

Aspen Process Manual Installation Notes

Aspen Properties Aspen Plus Installation Notes

Page 61: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 61/214

3 Installing Aspen Products 61

If you areinstalling

see

Mobile

Aspen SimulationWorkbook

Aspen Simulation Workbook Installation Notes

Client-Server Installation Using the AspenEngineering DVD

The following summarizes the steps for installing Aspen products for a client-server network configuration.

1   On the server machine, perform a  Server   installation of Aspen products.

2   Configure the server to perform calculations and data-processing activitiesfor the user PCs.

3   On each user PC, perform a  Standard   installation of Aspen products.

4   Configure the user PCs to use the remote server.

5   Verify communications between the server and the user PCs.

Note: Only system administrators should perform this type of installation.

Installing Aspen Software on a Server

Note: You must install any of the following products on the  same server machine and specify the  same working folder  as the Standard installation of Aspen Plus:

  Aspen Adsorption

  Aspen Chromatography

  Aspen Custom Modeler

  Aspen Plus Dynamics

This ensures that these products can find the .appdf  file containing the

physical property configuration when using Aspen Plus/Aspen Properties forphysical property calculations.

Installing the Software

To Install Aspen server software on the server machine:

1   Log on to the computer, using an account with Local Administratorprivileges.

2   Insert the Aspen Engineering  DVD (DVD 1) into the DVD drive.

Note: If the installation does not start automatically, click  Start | Run. In

the  Run dialog box, enter  <drive>:\setup (where  <drive>   is the drive

letter assigned to your DVD drive); then click  OK.

Page 62: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 62/214

62 3 Installing Aspen Products

The  AspenTech DVD Browser  window appears.

3   Click the Products  tab.

Note: If you want to see only products that you are licensed to install, selectthe   Show Licensed Products Only  check box.

A license requirement dialog box appears.

4   Click  OK.

Page 63: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 63/214

3 Installing Aspen Products 63

The License Configuration  Wizard appears.

Note: If you are installing the SLM Server, see   Software License Manager (SLM) Installation and Reference Guide,  which is contained on the

Documentation  DVD.

5 Click Next.

The License Configuration Type   dialog box appears.

6   Accept the default  Both  option and click  Next.

Note: You can click  None. If you click  None, skip to Step 10 below.

Page 64: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 64/214

64 3 Installing Aspen Products

The  License Files   dialog box appears..

7   Do the following:

o   If you have one or more standalone license files that are local to yourcomputer, click  Add License File, and then use the  Open  dialog box

to locate the license files (*.lic,  *.slf ). Then click  Next.

-and/or-

o   If you have licenses that are obtained from a network license server,

click  Next.

The License Servers  dialog box appears.

8   In the License Servers  dialog box, enter the  License Server  name and

click  Add Server, and repeat until all applicable  License Server  namesare included in the list. Then click  Next.

Page 65: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 65/214

3 Installing Aspen Products 65

The Determining Product Licenses   dialog box appears.

9   After the Licenses  list is populated with all licenses found, click  Next.

10  Click   Products | Aspen Engineering; then  click  Install.

The Windows Installer  view appears briefly as it prepares for installation.One of the following  AspenTech Installer  dialogs appears.

This version of the Aspen Installer dialog appears when no aspenONE

products are installed:

This version appears when one or more aspenONE   products are installed:

Page 66: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 66/214

66 3 Installing Aspen Products

11   Whichever screen appears, click  Next   to continue.

Note: If you have already installed one or more aspenONE products, the next

screen will be the  Program Maintenance  screen.

Page 67: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 67/214

3 Installing Aspen Products 67

If you want to install additional programs or remove some (but not all)

existing Aspen programs:

o   Click  Modify; then click  Next. Skip to Step 15 below.

The Computer Configuration Type  dialog box appears.

12  Click  Server Install  to install the Aspen software on a single computer.

The Aspen Engineering V7.3 Setup  dialog box appears.

13  Click  Next.

The License Agreement dialog box appears.

14  Review the license agreement. If you accept this agreement, click  Yes, I

accept the terms in the license agreement. If you do not accept it,

Page 68: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 68/214

68 3 Installing Aspen Products

click  No, I do not accept the terms in the license agreement.  If you

click on  No, you will not be able to continue with the installation.

The Choose Destination Location   dialog box appears.

15  To specify a different folder, click  Browse, then navigate to the correctfolder. When you are satisfied with the installation folder (default or your

choice), click  Next.

The Feature Selection   dialog box appears.

16  On the  Feature Selection  dialog box, click the Aspen product(s) you

want to install on the computer by clicking on the tree of products and

product features. Click the  PLUS SIGN  and   MINUS SIGN  symbols to display orhide branches of the tree. For each feature, you can select options that

control the installation.

Initially, the icons appear with the red “x”. Open a tree and the icon therewill also have a red “x”. When you click on the subfeature “x” icon, the

following menu appears:

17  On this menu, select how you want that program to be installed.

Note: For an explanation of the icons, click  Help.

Page 69: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 69/214

3 Installing Aspen Products 69

Changing Product/Subfeature Folders

For a selected product, you can change the default destination location of itsproduct directory. For some features you can also change the default

destination folder of product subfeatures.

To change the destination location of a selected Aspen product orsubfeature

A  On the  Feature Selection  dialog box, click   Change.

The  Change Current Destination Location  dialog box appears.

The default destination is:

C:\Program Files\AspenTech

B  On the  Change Current Destination Location  dialog box, either

o   browse to the directory that you want to specify as the rootdestination directory under which all AspenTech products for

this software version  will be installed  on this computer . (If adialog box appears prompting you for permission to create the

folder, click  Yes.).

-or-

o   in the Folder name  field, type the path to the directory that

you want to specify as the root destination directory underwhich all AspenTech products for   this software version  will be

installed  on this computer . (If a dialog box appears promptingyou for permission to create the folder, click  Yes.).

Page 70: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 70/214

70 3 Installing Aspen Products

Note: Once the installation of any Aspen product has been completed for

this software version on this computer, you cannot change the location of 

the AspenTech folder.

Note the following product restrictions:

Product Restriction

AspenEconomicEvaluation

The Aspen Economic Evaluation product directory must be installedno deeper than the third level of the directory structure. Forexample: D:\Program Files\AspenTech\Aspen EconomicEvaluation V7.3

C  Click  OK.

You are returned to the  Feature Selection   dialog box.

18  Click  Next  to continue.

19   This screen may appear regarding pre-requisites:

If it appears, click  Report  to get detailed instructions on the productsrequired, with links to download and configuration instructions. Then:

o   You should download all the required products first, since some

installations may require reboots.o   You should print the page you get with  Report   for reference.

o   If any of the prerequisites is marked  Exiting AspenTech InstallerRequired, you should exit the installer by clicking  Exit.

When you are done installing the prerequisites, if you did not have to exitthe installer, click  Recheck. If you did have to exit the installer, restart

the Aspen Engineering installation, if necessary. When doing so, when thismessage appears, click  Yes.

Page 71: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 71/214

3 Installing Aspen Products 71

Then the various screens starting with  Welcome  screen will appear. ClickNext  (and  Yes  on the  License Agreement  screen) to get through them.Your selections on the  Feature Selection  screen will be preserved. If you

have satisfied all the pre-requisites, the  Prerequisite Validation   screenwill not reappear.

Configuring Aspen Products at Install Time

Depending on the products you are installing, additional dialog boxes may

appear, prompting you for product-specific information.

If you are installing you are prompted for

Aspen Basic Engineering If the Aspen Basic Engineering Broker  windowappears, see Aspen Basic Engineering InstallationNotes."

Aspen OnLine If the   User name and Password  window appears,see "Aspen OnLine."

If you install Aspen Remote Simulation Service, you are prompted for theusername and password of an account which will be used to run this service.

Page 72: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 72/214

72 3 Installing Aspen Products

When you install the Aspen Properties Enterprise Database feature of any

product and only one instance of MS SQL Server or MS SQL Server Express is

installed on the computer, you are prompted for the database admin nameand password, and if more than one SQL server instance is installed, whichone to use.

If you are installing Aspen Properties Mobile, you will be prompted for theLDAP configuration for authenticating users of the client app.

Page 73: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 73/214

3 Installing Aspen Products 73

The LDAP Path   is an LDAP URL for the domain in which users are

authenticated. Typically this looks like  LDAP://domain.company.comwhere domain  is the Windows domain containing the user accounts andcompany.com is the Internet domain for the network.

The  LDAP Web Configure  is a group within this domain containing usersallowed to access Aspen Properties Mobile.

Ready to Install20  Click  Next  until the  Ready to Install the Program  dialog appears.

Page 74: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 74/214

74 3 Installing Aspen Products

21  Review your selected installation options. (To modify any selected option,click  Back  to navigate to the appropriate dialog box and make the

changes.)

22  To complete the installation, click  Install.

23  Wait as the installation begins. The  Installing Aspen Engineering

screen appears on which you can monitor the progress of the installation.

Setup Complete

Once the installation is finished, the  Wizard Completed  dialog box appears.

Page 75: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 75/214

3 Installing Aspen Products 75

24  Click  Finish.

25  A message box appears asking you to restart your computer. Do either of 

the following:

o   Click  Yes to restart your computer right away.  The systemshuts down and reboots.

o   Click  No to restart it later.

26  When the system reboot is complete, log on to Windows using an accountwith local Administrator privileges.

Configuring a Windows Server

as an Aspen HostNote: This does not apply to Aspen Basic Engineering.

After you complete the installation of the Aspen server components on theserver machine, you must configure the server as an Aspen host.

Each user connecting to the Windows Server must belong to one of thefollowing:

  A local user account or group on the server.

  An account or group in the domain to which the server belongs.

  An account or group in a trusted domain.

Important: Each user account that connects to the server must also begranted Log on as a Batch Job  access to the server.

Page 76: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 76/214

76 3 Installing Aspen Products

Adding Windows Server Accounts

The following sections provide detailed instructions for configuring useraccounts on Windows Server, using sample groups, accounts, and domains.

Creating Local Group and User Accounts

To create local group and user accounts

1   On the desktop, click Start | Settings | Control Panel |

Administrative Tools | Computer Management.

The Computer Management  console appears.

2   In the console tree expand System Tools | Local users & Groups; then

click  Groups.

3   On the Action   menu, click  New Group.

The New Group   dialog box appears.

4   Enter a Group Name for the local group, for example, Local1. Then clickCreate.

5   In the console tree, click Users,  and on the  Action  menu, click  NewUser.

The New User dialog box appears.

6 In the New User dialog box, type the following information:

In this field type

Username The name of the new user.

Password The password based on your local security policy.Confirm Password

7   Clear  User must change password at next logon  and click  Password

never expires.

8   Click  Create; then  close the dialog box.

9   Double-click the new user you just created. In its  Properties  dialog box,

click the  Member of  tab.

10  Click  Add.

11  Type the name of the group and click  Check Names  to verify it is correct.Then click  OK.

12  Click  OK  to close the  Properties  dialog box.

13  Repeat Steps 4 through 12 to create or add more users to the group.

14  When you finish adding users to the group, close the  ComputerManagement console.

After you have created new local group and user accounts, you must grant

access to the user PCs.

Setting User Rights

Each user account that connects to the server must be granted  Log on as aBatch Job  access to the server.

Page 77: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 77/214

3 Installing Aspen Products 77

To grant access to the server for local users

1   On the desktop, click Start | Settings | Control Panel.

2   Double-click  Administrative Tools; then double-click  Local SecurityPolicy.

3   Double-click  Security Settings, double-click Local Policies, and then

double-click User Rights Assignment.4   Double-click the user right Log on as a Batch Job.

5   Click  Add User or Group.

Click  Locations, and select the local computer.

Type the names of accounts to which you want to assign the right, then

click  Check Names.

6   Click  OK; then click  OK  again.

7   Confirm that the changes have taken effect locally by closing the  Local

Security Policy  window and re-opening it.

The newly assigned rights should appear under the  Effective Settings

columns.

You can now proceed with the installation on the user PCs.

Installing Aspen Products onUser PCsThe following table summarizes the steps for installing Aspen products on

user PCs in a client-server network configuration.

1   On each user PC, perform a  Standard   installation of Aspen products.

2   Configure the user PCs to use the remote server.

Configuring Installed AspenProducts on User PCsBefore you can run Aspen simulation/calculation software installed on theserver machine, you must specify the name of the server the first time you

run the product from the user PC.

Specifying a Remote ServerThe following sections contain detailed instructions on specifying the remoteserver for Aspen products.

Page 78: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 78/214

78 3 Installing Aspen Products

Aspen Modeler Products:

Aspen Adsorption

Aspen Chromatography

Aspen Custom Modeler

Aspen Plus Dynamics

To specify a remote server from a user PC running any of the AspenModeler products:

1   On the desktop, click Start | Programs | AspenTech | Process

Modeling V7.3 | <Aspen product >| <Aspen product >.

2   On the menu bar, click  Tools | Server Configuration.

3   In the Server Configurations  dialog box, click  Add.

The Servers   dialog box appears:

4   Type a  Current configuration name.

This name can be the name of the computer where the simulation serversoftware will run, or it can be a name with meaning to you only.

5   Click  Add Host.

The Host Properties  dialog box appears.

6   On the Host Properties  dialog box, enter the following information:

Page 79: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 79/214

3 Installing Aspen Products 79

In this field Do this

Host name Type the name of the server where thesimulation server software is installed.

Note:  Ensure the accuracy of both caseand spelling of the server name. The

name is used to resolve the networkaddress of the computer and must be in a

form recognizable to your Domain NameServer.

User name Type the user name for the account onthe server computer that you will use torun the server software.

Password Type the password for the account on theserver computer that you will use to runthe server software.

7   Click  OK.

8   In the Servers  dialog box, click the name of the server you just added as

the  Host Computer.

For example:

9   In the Configuration Properties  section, specify the following:

In this field do this

Working folder Specify the pathname of the root folder onthe remote machine, where run-time data,

such as simulation snapshots and plotdata, will be stored. For example,

Page 80: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 80/214

80 3 Installing Aspen Products

In this field do this

C:\My Documents\AspenTech\  AspenProduct Note: Snapshots and plot data will bestored in folders of this working folder onthe remote server machine.

Executable folder Type the pathname of the folder where thesimulator executables are installed on theremote machine. For example,C:\ProgramFiles\AspenTech\AMSystem V7.3\Bin

Prompt for Password (optional)   Select this option if you want the system toprompt for the remote password ratherthan use the stored one associated with thehost.

Visible Console (optional) Select this option if you have your owncode linked into the server and want todebug it. This is an advanced option and isnot for normal use.

10  Click  OK  to accept your changes and close the  Servers  dialog box.

11  In the  Server Configurations  dialog box, click  OK.

You are notified that you must restart the Aspen product for the changes you

have made to take effect.

After you have restarted the Aspen product, you can run simulations and/ or

calculations from your PC on the remote server you specified.

Checking the Status Bar

To quickly verify that an installed product is using the remote

configuration you specified

  Look for the configuration name on the status bar, for example:

Verifying Client–ServerCommunication

To verify that the installation on the user PC is successfullycommunicating with the server running the Aspen simulation and

calculation server software

1   Ensure that you have successfully installed and configured the software onboth the server and on the user PC.

2   If you have not already done so, restart the user PC.

3   Verify the client-server communication for the installed Aspen products, asdescribed in this section.

Page 81: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 81/214

3 Installing Aspen Products 81

4   Verify the installation of Aspen products on the user PCs, using verification

procedures in the appropriate product tabs.

Aspen Adsorption, Aspen Chromatography, AspenCustom Modeler, Aspen Plus Dynamics

If you encounter any problems running any of these Aspen products, you canensure that  REXEC  is working correctly on the user PC.

To ensure that REXEC is working correctly on the user PC:

  At the command prompt on the user PC, type:

rexec   MachineName pathname\sim_server.exe Name   (DomainName:UserName):   UserName

Password   (DomainName:UserName):

For example, where the:

  Machine name is  Blue

  Path is  C:\Program Files\AspenTech\AMSystem V7.3\bin\   Domain is  aspen.com

  UserName is  Fred

You would type:

rexec Blue C:\Program Files\AspenTech\AMSystemV7.3\bin\sim_server.exeName(aspen.com:Fred): FredPassword (Blue:Fred):

A message similar to the following example indicates a successful verification:sim_server.exe (Version 23.0) built on Nov 5 2008 at 17:40:23

If you encounter any other messages, see "9 Troubleshooting."

Verifying the InstallationFor most Aspen products, you can verify that the installation succeeded by

running the Aspen product you installed. However, some Aspen products haveproduct-specific verification requirements. For verification (and configuration)information, see "Chapter  5 Verifying and Configuring Aspen Products."

Configuring Installed AspenProductsAfter installation is complete, the following Aspen products require additionalconfiguration.

Aspen Product Notes

Aspen Basic

Engineering

Log on as Administrator and configure Aspen Basic Engineering.

For instructions, see "Verifying an Aspen Basic Engineering

Page 82: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 82/214

82 3 Installing Aspen Products

Aspen Product Notes

Installation."

Aspen OLI Interfacein Aspen Plus

Complete the installation with the OLI Alliance Suite.

Aspen OnLine See " Aspen OnLine

This section contains   the following sections:

  Configuring Aspen OnLine

  Verifying an Aspen OnLine Installation

Note: If you have an older version of Aspen OnLine

installed, see "Aspen OnLine," which explains how to backup your existing files so you don’t lose your work.

Configuring Aspen OnLine."

Page 83: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 83/214

4 Individual Product Installation Notes 83

4 Individual ProductInstallation Notes

Some Aspen Engineering products have product-specific installation notes.

Those notes are listed below in alphabetical order.

Installation Notes

Aspen Basic EngineeringInstallation Notes

Caution: If upgrading a V7.x installation (where x = 1 or 2), create a

backup of workspace libraries and customized files before installingV7.3.

V7.3 replaces V7.x Program Files, updates AspenTech standard workspacelibraries, and uses the same workspaces as V7.x.

V7.3 will install a new set of program files, for example, C:\ProgramFiles\AspenTech\Basic Engineering V7.3, and will remove the V7.x program

files.   The following files are replaced and should be copied to anotherfolder before starting the V7.3 installation:

  All customized files under:

C:\Program Files\AspenTech\Basic Engineering V7.xo   Server  customized files may include:

  DataServices\bin\ Broker.ini

  AspenTech delivered workspace library files in folder:

C:\AspenZyqadServer\Basic Engineering16.2\WorkspaceLibrarieso   Datasheets, templates, and KBs

o   DataModel\StandardModel.azcl (source for datamodel

customizations)o   StandardLibrarySet.cfg (customization to standard library

configuration)

  Client  Customized files may include:o   Mapping files for SmartPlant foundation in:

  UserServices\bin\EF\Mapping

Page 84: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 84/214

84 4 Individual Product Installation Notes

After the V7.3 installation, reapply your changes to all modified files. The

Upgrade will install a new version of these files with important changes that

you should not discard by simply overwriting the newly delivered files.Uninstall any earlier (pre-release) versions of Aspen Basic Engineering V7.3before installing this release of Aspen Basic Engineering V7.3.

Caution: On 64-bit operating systems, you must uninstall V7.x beforeinstalling the 64-bit version of Aspen Basic Engineering – upgrade

from V7.x to V7.3 is not supported for 64-bit version.

Installation Types

You have two options for installation type:

  Upgrade

  Full

Upgrade installationUse this option when V7.x is already installed. Review the previous Caution

statement for creating a backup of workspace libraries and customized files. If Aspen Basic Engineering V7.x is installed on the client and/or server

machines, the installation program will prompt with the following dialog:

Choose  Upgrade or Repair. The installer will upgrade only those options that

were installed in V7.x.

Page 85: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 85/214

4 Individual Product Installation Notes 85

If you wish to modify the installed options, first uninstall V7.x. After a

reboot, you can perform a full installation, selecting the options you wish to

install.

Note: Uninstalling V7.x will not remove your workspaces or workspacelibraries. A full installation of V7.3 will use the V7.x workspaces and

workspace libraries. Refer to the Caution statement at the beginning of thissection for creating a backup of workspace libraries and customized files.

Full installation

Use this option when Aspen Basic Engineering V7.x is not previously installed.

Aspen Basic Engineering can be installed as either a Standard or a Serverinstallation:

  The Standard   install option can be used to install all client and server

components onto a single machine. Such an installation lets the machineoperate as a server, as well as allowing the user to connect to the localserver or other server installations. This can be convenient for

administrators and customization users. On 32-bit machines, a default

Access workspace can be used for testing. On 64-bit machines, the Accessdatabase is not supported; the workspace will have to be created in the

Administration tool using an RDB installed on the server machine or on a

networked machine. For details, see   Aspen Basic Engineering Standard Installation Notes.

  A  Client  only install is done by clicking on the  Standard   Install button

and from selecting only  User Services   components. For details, see

"Aspen Basic Engineering Client Installation Notes."

  The Server  only install option will install Data Services and Workspace

Libraries. For details, see “ Aspen Basic Engineering Server Installation

Notes.” 

Note: Most installations will be either server only or client only.

Aspen Basic Engineering StandardInstallation Notes

To install Basic Engineering:

1   Follow the procedure outlined in "Client-Server Installation," until theComputer Configuration Type  dialog box appears.

2   Click  Standard Install.

The Feature Selection   dialog box appears.

3   Select the feature(s) you wish to install. For details, see “Client-Server

Installation.” 

Page 86: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 86/214

86 4 Individual Product Installation Notes

The  Aspen Basic Engineering Broker  dialog box appears.

4   On this dialog, your  Name  must be defined to allow the broker to run asan existing or new user.

Existing User. To access the database as an existing user, enter an

existing (valid) username in the Name field (this includes a domain name;for example,  MYDOMAIN\AZUSER_YourName) and the correctpassword in the Password field.

New User. To access the database as a new user, enter your username inthe  Name  field (this includes a domain name; for example,MYDOMAIN\AZUSER_YourName) and your password in the  Password

field. The install creates this new username on the local machine. Youmust also assign user privileges.

Important: This password must be valid according to your companypassword security policy. If you enter a password in this field,  please

record it for future reference  as it may be required if you uninstall and

then re-install the application under a previously used broker account.

5   Click  Next  to continue.

6   The   Aspen Basic Engineering Business Server Host  dialog box

appears.

Page 87: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 87/214

4 Individual Product Installation Notes 87

7   In the Host  field, type the default server (Business Server Host) that the

client applications will connect to.

8   Click  Next  to continue.

If ProVision was specified as an install option, the  ProVision  dialog box

appears prompting you to enter the name of the ProVision configuration file.

9   If you wish to change these default locations, click Browse to navigate to

the file.

Page 88: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 88/214

88 4 Individual Product Installation Notes

10  Click  Next  to continue.

11  Return to the section  Ready to Install  for instructions on how tocomplete the installation.

For information about changing licensing, see   Software License Manager 

(SLM) Installation and Reference Guide  on the  Documentation  DVD.

Aspen Basic Engineering Client InstallationNotes

To install Aspen Basic Engineering:

1   Follow the procedure outlined in "Client-Server Installation," until theComputer Configuration Type  dialog box appears.

2   Click  Standard Install.

The Feature Selection   dialog box appears.

3   Expand the Aspen Basic Engineering feature, and then select either all oronly those applications you require from beneath  User Services  only. Do

not select any   Data Services   or WorkspaceLibraries components for aClient   install.

4   The   Aspen Basic Engineering Business Server Host  dialog boxappears.

Page 89: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 89/214

4 Individual Product Installation Notes 89

5   In the Host  field, type the default server (Business Server Host) that the

client applications will connect to.

6   Click  Next  to continue.

If ProVision was specified as an install option, the  ProVision  dialog box

appears prompting you to enter the name of the ProVision configuration file.

7   If you want to change these default locations, click Browse to navigate to

the file.

Page 90: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 90/214

90 4 Individual Product Installation Notes

8   Click  Next   to continue.

9   Return to the section Ready to Install  for instructions on how tocomplete the installation.

For information about changing licensing, refer to   Software License Manager 

(SLM) Installation and Reference Guide, which is contained on theDocumentation DVD.

Aspen Basic Engineering Server Installation

Notes

The following section summarizes the steps required to install the Aspen BasicEngineering server application on a server host. For a client-serverconfiguration, follow these steps.

1   On the server machine, perform a  Server   installation.

2   Perform a  Client  installation on each Client PC.

3   Configure the Client PCs to use the remote server.

4   Verify communications between the Server(s) and Clients (refer also to

the Administration help).

Note: Only system administrators should perform this type of installation.

Aspen Basic Engineering Server Installation1   Follow the procedure outlined in "Client-Server Installation" until the

Computer Configuration Type  dialog box appears.

2   Click  Server Install.

Page 91: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 91/214

4 Individual Product Installation Notes 91

3   Select the feature(s) you wish to install. For details, see "Client-Server 

Installation."

The  Aspen Basic Engineering Broker  dialog box appears.

On this dialog,  Name  must be defined to allow the broker to run as a user.

o   Existing User. To access the database as an existing userenter an existing (valid) username in the Name field (this

should also include a domain name; for example,MYDOMAIN\AZUSER_YourName) and the correct passwordin the  Password  field.

o   New User. To access the database as a new user enter your

username in the Name field (this should also include a domainname; for example,  MYDOMAIN\AZUSER_YourName) andyour password in the  Password  field. The install creates this

new username on the local machine. You must also assign user

privileges.

Important: This password must be valid according to your companysecurity policy. If you enter a password in this field,  please record it forfuture reference  as it may be required if you uninstall and then re-install

the application under a previously used broker account.

4   Click  Next  to continue.

5   Return to the  Ready to Install  section to complete the installation.

Page 92: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 92/214

92 4 Individual Product Installation Notes

Uninstalling and/or Reinstalling

Uninstall any  pre-release  versions of Aspen Basic Engineering V7.3 beforeinstalling Aspen Basic Engineering V7.3.

Note: You do not need to uninstall Aspen Zyqad 2006.5, Aspen Basic

Engineering V7.0 (or previous versions) before installing Aspen BasicEngineering V7.3. These versions can coexist on the same machine. Aspen

Basic Engineering V7.3 will update versions V7.1 or V7.2 – it will use the

same workspaces and workspace libraries. V7.3 will not coexist with V7.1 orV7.2.

Disconnecting Users from the Server

When you are reinstalling, users/clients need to be disconnected from the

Aspen Basic Engineering Server. You can do this in two ways:

  Ask users to disconnect, and then reboot the server machine. Ask the

users not to reconnect until the installation is complete.

  Alternatively, you can stop the Aspen Basic Engineering Server in the

following way:

1   On the Start   menu, click  Control Panel | Administrative Tools |Services.

2   Click  AZ162Broker.

3   Right-click and select Stop. (You can also prevent the  Broker  servicefrom automatically restarting by clicking  Properties. On theProperties dialog box, navigate to the  General  tab; then switch the

startup type from  Automatic  to  Manual  to prevent it from being

restarted.)

4   When the installation operation is complete, ensure the  AZ162Broker

service startup type is switched back to  Automatic.

Aspen Batch Process Developer

Installation NotesYou can modify the location of the Working Folder used by Aspen Batch

Process Developer at install time. By default the Aspen Batch Process

Developer Working Folder is a subfolder under the Aspentech Working Folder.The Aspentech working folder has a restriction that it must be set to a localdrive, but the Aspen Batch Process Developer working folder does not have

this restriction. To set the working folder to a network drive, you can:

  modify the folder location from the application

or

  modify the following registry entries after installing.

Page 93: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 93/214

4 Individual Product Installation Notes 93

To modify the location of the Working Folder used by Aspen Batch

Process Developer:

  Modify the paths for the following registry entries to point to the desiredlocation of the Working Folder:

HKCU\Software\AspenTech\Batch Plus\25.0\Batch Plus\Working Dir, Dir

HKLM\Software\AspenTech\Setup,BATCHPLUS250WORKINGDIRdir

Aspen Exchanger Design andRating Installation NotesV7.3.1 Exchanger Design and Rating (EDR) will not co-exist with the V7.3version of Exchanger Design and Rating. This means installing V7.3.1 EDR

will “upgrade” the V7.3 version if it was installed previously. V7.3.1 EDR canalso be installed on a machine where V7.3 EDR was never installed. The

installer therefore functions in 2 modes:

Mode 1 (“Upgrade” Installation): if V7.3 EDR has been installed, theinstaller will detect this and upgrade the V7.3 EDR installation toV7.3.1.

Mode 2 (“Full” Installation): if V7.3 was not previously installed on amachine, the installer will detect this and perform the necessaryfunctions to complete a full V7.3.1 installation.

In order to activate the V7.3.1 EDR installation, please select thefollowing option within the Aspen Tech Installation Browser - “AspenEngineering (for Upgrade)”:

Page 94: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 94/214

94 4 Individual Product Installation Notes

  If you select the Aspen Properties Sub-Option, have Aspen Properties V7.2

installed:

1. If you have no other  AspenTech V7.2 products that depend on AspenProperties V7.2, Aspen Properties V7.2 will be replaced by AspenProperties V7.3.

2. If you   have  other AspenTech V7.2 products that depend on Aspen

Properties V7.2, Aspen Properties V7.2 will be left alone and AspenProperties V7.3 will   be installed .

Aspen Economic EvaluationInstallation NotesV7.3.1 Economic Evaluation will not co-exist with the V7.3 version of Economic Evaluation. This means installing V7.3.1 EE will “upgrade” the V7.3

version if it was installed previously. Customized libraries and projects

created using V7.3 will be preserved during this upgrade. However, it is

recommended to back-up these files prior to performing this upgrade. Also,V7.3.1 EE can be installed on a machine where V7.3 EE was never installed;

thus the installer will function in two modes:

  Mode 1 (“Upgrade” Installation): if V7.3 EE has been installed, theinstaller will detect this and upgrade the V7.3 EE installation to V7.3.1.

  Mode 2 (“Full” Installation): if V7.3 was not previously installed on a

machine, the installer will detect this and perform the necessary functionsto complete a full V7.3.1 installation.

In order to activate the V7.3.1 EE installation, click the following option withinthe Aspen Tech Installation Browser -   Aspen Engineering (for Upgrade):

Page 95: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 95/214

4 Individual Product Installation Notes 95

Aspen HYSYS Installation NotesIt is important to note that the HYSYS install has two parts: Process ModelingHYSYS (Basic) and Process Modeling HYSYS (Advanced).

The following licensable products are installed with the Process Modeling

HYSYS (Basic) part:   Aspen HYSYS

  Aspen HYSYS Amines

  Aspen HYSYS Dynamics

  Aspen HYSYS Dynamics Runtime

  Aspen Pipeline Hydraulics - OLGAS 3-Phase

  Aspen HYSYS Pipeline Hydraulics - OLGAS 2-Phase

  Aspen HYSYS Pipeline Hydraulics - PIPESYS

  Aspen HYSYS Offline Optimizer

  Aspen HYSYS Upstream

  Aspen HYSYS Upstream Dynamics   Aspen HYSYS Petroleum Refining

Some key new HYSYS functionality is available only when you install ProcessModeling HYSYS (Advanced). This new functionality allows simulations using

Aspen Properties-based thermodynamics.

Additionally, the Process Modeling HYSYS (Advanced) installation installs thefollowing licensable products:

  Aspen Plus EO Model Library

  Aspen HYSYS CatCracker

  Aspen HYSYS Reformer

  Aspen HYSYS Hydrocracker   Aspen Custom Modeler

Installing the Aspen Properties EnterpriseDatabase

The AspenTech Installer looks for an existing SQL Server (2005, 2008, or SQL

Express 2005) installed on your computer. See the  Troubleshooting  sectionfor issues related to installing SQL Express.

Note: Due to problems encountered with MSDE and MS SQL Server 2000,Aspen Properties Enterprise Database no longer uses these SQL Servers.

If multiple SQL Servers of these versions are found, the installer will ask

which one to use:

Page 96: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 96/214

96 4 Individual Product Installation Notes

Note: The server must be configured to  SQL Server and Windowsauthentication mode before you can use it with Aspen HYSYS. See"Configuring Microsoft SQL Server or SQL Express."

At some sites, policy may prohibit the installation of SQL Server on individualcomputers. In this case, the legacy databanks may be used or Aspen Plusmay be configured to use SQL Server on a designated computer.

To install Aspen HYSYS without installing a SQL Server:

1   Create the following registry entry:

[HKEY_LOCAL_MACHINE\SOFTWARE\AspenTech\Setup]"NOSQLExpress"=dword:00000001

2   Install Aspen HYSYS as usual.

Note: The Enterprise databases are installed on  C:\Documents andSettings\All Users\Application Data\AspenTech\APED V7.3  (or

D:\Documents and Settings\All Users\Application

Data\AspenTech\APED V7.3). This location cannot be compressed or thedatabases will not be installed. SQL server does not support databases on

compressed drives.Note: Aspen Properties Enterprise Database no longer uses Microsoft SQLServer Desktop Edition (MSDE) or MS SQL Server 2000 due to problemsencountered with these SQL servers.

In order to use the Aspen Properties Enterprise Database with correspondingAspen products (Aspen Plus, HYSYS, and so on),  SQL 2005 SP3  is theminimum requirement as an install pre-requisite. Be sure to choose Mixed

Mode (in the Windows Authentication and SQL Server Authentication) during

Page 97: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 97/214

4 Individual Product Installation Notes 97

the "authentication mode" step of the SQL Server installation. If you are not

using mixed mode and have finished the Aspen installation, follow these steps

to ensure the mixed authentication mode is enabled.

For Microsoft SQL Server:

1   Run  Start | Programs | AspenTech |Process Modeling V7.3 | Aspen

Properties | Aspen Properties Database Configuration Tester.2   Click   Start.  An "Incorrect SQL Engine Authentication Setting" dialog

appears. Follow the instructions, then click  OK  and it will correct theauthentication setting to  Mixed  Mode for you.

For SQL Server Express, the user interface for configuring the server is not

installed by default. If you do not have it, download it from Microsoft:http://www.microsoft.com/downloads/details.aspx?FamilyId=C243A5AE-4BD1-4E3D-94B8-5A0F62BF7796&displaylang=en and install it before

performing these steps:

1   Run  Start | Programs | Microsoft SQL Server 2005 | SQL ServerManagement Studio Express.

2   In the  Connect to Server  window, select the server name and  Windows

Authentication. Click  Connect.

3   In the  Microsoft SQL Server Management Studio Express  window

tree on the left, right-click the name of the server and click  Properties.

4   In the Server Properties  dialog, at the left, click  Security.

5   Under  Server authentication, select  SQL Server and Windows

authentication mode, and click  OK.

6   In the object explorer, right-click the name of the server and select

Restart. The change will take effect after that.

Verifying the Aspen Properties Enterprise

Database Installation1   On the desktop, click Start | Programs | AspenTech | Process

Modeling V7.3 | Aspen Properties | Aspen Properties Database

Configuration Tester.

2   When the Database Configuration Tester window appears, click  Start.

The tester will perform several tests and report the results.

  License availability: The tester verifies a license for Aspen Plus or Aspen

Properties is available.

  Configuration file permissions: The tester verifies that the configuration

file was installed with the correct permissions.

  SQL engine authentication settings: The tester reports all servers thathave at least one Aspen Properties database that is registered on this

computer. On the  localhost  line, it reports the authentication mode of thelocal server and whether there is any problem with it. For other servers it

cannot check this status, so it only reports what is required.

o   First, it verifies that it can connect to the database at all, witheither a  Connection Successful  message or a messageindicating the error that occurred.

Page 98: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 98/214

98 4 Individual Product Installation Notes

o   Next, it attempts to read the database as Aspen Plus or Aspen

Properties would do. This should report  Granted/Successful   if 

the database is configured for access from these programs, orDenied/Failed   otherwise. For a non-customized new installation,the databases APV73, NISTV73, and FACTV73 should all be

accessible.

o   Finally, it attempts to read the database as the DatabaseManager would do. This should also report  Granted/Successful 

or  Denied/Failed  based on the security options. For a non-customized new installation, the databases APV73, NISTV73,

and FACTV73 should all be accessible.

Installing Aspen HYSYS Dynamics Runtime

To install Aspen HYSYS Dynamics Runtime, you must install two AspenEngineering products:

  Aspen Operations Support | Aspen OTS Framework

  Process Modeling (HYSYS)

Installing OLI Engine for HEO

This software is necessary to use the OLI electrolytes in HYSYS. OLI Engine

for HEO is not distributed by AspenTech. Contact OLI Systems to get the

software and a license for it. Once installed and configured, HYSYS willautomatically detect its presence and the OLI Electrolytes feature withinHYSYS will be enabled.

OLI HardLock Security Key

You must have an OLI HardLock security key and serial number to enableOLI’s license manager. Existing customers will automatically get the OLIHardLock security key and serial number as part of the continued licensing of 

the software from OLI. If you do not have the key or serial number, contact

OLI Systems (973-539-4996).

Installing the HardLock Security Key

To install the HardLock security key

Attach the key to the parallel port located on the back of your computer.

  If you have the USB version of the HardLock key, attach it to any available

USB connection.   If you have a parallel port version of the HardLock key, and you have a

printer connected to the parallel port, unplug your printer. Connect thekey, and then reconnect your printer to the HardLock key. The HardLock

key does not interfere with your printer.

Note: If you have a parallel port security key for another software product,please make sure that the OLI HardLock key is connected directly to the

parallel port and is first in the chain of keys.

Page 99: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 99/214

4 Individual Product Installation Notes 99

OLI Engine in Aspen HYSYS

The OLI Engine uses InstallShield to lead you through a typical Windowsinstallation process. This installation is available in two formats:

  A self-extracting executable file named  OLI Engine in Aspen HYSYS

V7.3.8.2.3.exe  that is distributed on the OLI Systems website.

  A product distribution DVD from OLI Systems.

The OLI Engine in Aspen HYSYS V7.3.8.2.3.exe will install the OLIengine files to C:\Program Files\OLI Systems\OLI Engine 8.2\AspenHYSYS V7.3\OLI Engine

Installing

You must download this .exe from the OLI Systems website. If you alreadydownloaded the file, then go to Step 1 below. If you have not downloaded the

file yet, go to this site and follow the directions there to download:

http://support.olisystems.com

Note: The .exe is also on the product DVD from OLI. If you have a product

distribution DVD provided by OLI, then insert the DVD and run  X:\setup.exe(where  X: is the drive letter for your DVD). Or, open Windows Explorer, locate

setup.exe and double-click on it. Go to Step 2 below.

1   Open Windows Explorer, and double-click on this self-extracting file.

2   On the Welcome  dialog box, click  Next.

3   In the License Agreement  dialog box read the agreement, click  I

accept the terms in the License Agreement; then click  Next.

4   In the Customer Information  screen type your name and company

name. To complete the  Serial Number  field, you need the serial number

provided by OLI Systems. Click  Next.

5   In the  Configure Network License Server  dialog box SelectAutomatic. Click  Next.

6   On the Choose Setup Type   screen, click  Typical  or   Custom. Most users

select Typical. Click  Next.

Note: If you selected   Custom, the  Select Components  dialog box

appears. The default setting is to install all of the features (highly

recommended). If you are an experienced OLI user and you know thatyou do not want to use one or more of the optional databanks, then you

can clear them to save disk space.

7   On the Ready to Install   screen, click  Install.

The installation begins.

Results of Installation

The OLI interface files will be installed in the following directory:

C:\Program Files\OLI Systems\OLI Engine 8.2\Aspen HYSYS V7.3\OLI Engine

The following files will be present:

  Hypcalc.dll

Page 100: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 100/214

100 4 Individual Product Installation Notes

  OLIRegClient.dll

  OLIRegclient.rci

The version number of the Hypcalc.dll is 8.2.3 (or later).

HardLock Device Driver Installation Script

After the files are copied and the program group is populated, the HardLockdevice driver installation script starts. This is a very brief installation, and youare not prompted for any information.

1   Read the screen and close any other programs if needed.

2   Click  Next  to complete the installation. After the HardLock drivers areinstalled, the InstallShield  Wizard Complete  screen appears.

3   Click  Finish  to exit the installation.

Aspen OnLine Installation

NotesAspen OnLine consists of:

  Aspen OnLine Server, which communicates with CIM-IO to retrieveplant data and with simulators – for example, Aspen Plus, Aspen Custom

Modeler, or Aspen Utilities Planner – to run models.

  Aspen OnLine Client, which is the graphical user interface for AspenOnLine.

The Aspen OnLine Client is required, as a local client, on the computer where

Aspen Online Server is installed.

Page 101: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 101/214

4 Individual Product Installation Notes 101

Aspen Online DeploymentInstallation Notes   If you plan to use versions of Aspen Custom Modeler, Aspen Plus, Aspen

Model Runner, Aspen EDR, or HYSYS that are earlier than aspenONE V7.3,install them prior to installing any software from the aspenONE V7.3

suites.

  The required software from the Aspen Manufacturing Suite V7.3 can beinstalled either before or after the software from the Aspen Engineering

V7.3.

  A recommended implementation architecture, for a productionenvironment, is to use at least four different computers: one for the

engineering workstation (to build and maintain the process models andonline applications, one for the Aspen Online Deployment online

application server, one running Aspen Remote Simulation Service, andone running the Aspen APC Web Server. If you are using Aspen Local

Security, then this would typically be installed on the same machine as

the Aspen APC Web Server. The necessary simulators (Aspen CustomModeler, Aspen Plus, HYSYS, EDR) would be installed on both the

engineering workstation and on the remote simulation server.

  It is  strongly recommended  that all computers be members of a

Domain. If the online application server is installed on a computer that is

not a member of a Domain (that is, it is instead a member of aWorkgroup), then you must install Aspen Local Security and Aspen APCWeb Browser on that same computer – this is due to the way Windows

user authentication works.

  If you use the Aspen Remote Simulation Server, change the serviceproperties of the Aspen Remote Simulation Server service to log on as the

Local System account and to interact with the desktop.

Page 102: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 102/214

102 4 Individual Product Installation Notes

Aspen Online Deployment Post Installation Notes:

Desktop   No post-install configuration is required.

  In order for the product to be useful, you should have one or more of the

supported versions of HYSYS, Aspen Plus, Aspen Model Runner, Aspen

Exchanger Design and Rating, or Aspen Custom Modeler installed on thedesktop.

  When you first use the Aspen Online Deployment Desktop to connect to anOnline Deployment application server (using the  Online | Servers

menu), you may get a Windows Security Alert dialog box that informs youthat "Windows Firewall has blocked some features of this program":

Online Deployment Desktop. If you get this message, then click the

Unblock button on the dialog.

Page 103: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 103/214

4 Individual Product Installation Notes 103

Aspen Online Deployment Post Installation Notes:Server

Note: Some of these items require the use of the server configuration dialog.That dialog is invoked from the Aspen Online Deployment Desktop, running

on the online application server computer, using the menu item  Online |Configure Online Server.

  Install Aspen CIM-IO, Process Data, and ADSA (Aspen Data SourceArchitecture) from the Aspen Manufacturing Suite (DVD 2). This must be

done on any computer intended to be an Online Deployment online

application server. This can be done before or after installing OnlineDeployment.

  Install Aspen APC Web Server. This is best installed on a separatecomputer from the Aspen Online Deployment server. This can be done

before or after installing Aspen Online Deployment. See the  AspenManufacturing Suite Advanced Process Control Installation Guide   for

installation procedures.

  Identify or install the security server. Aspen Online Deployment requiresthat security be provided by either Aspen Local Security or by an Aspen

Framework Server.

  Select or change your security server, if needed.

1   Log on using the account name and password of an account in the

Administrators group of the computer where the software is installed.

2   Click  Start | Programs | AspenTech | AFW Tools. The AFW Tools

dialog box is displayed.

3   Select the Client Registry Entries  tab.

4   In the Name  column, double-click  URL. The URL defines the location

of the security server’s interface,  pfwauthz.asp. The  Update

Registry dialog box is displayed.

5   In the Data  field, enter the security server location information. For

example,http://hostname/aspentech/afw/security/pfwauthz.asp,

where hostname   is the name of the computer where the securityserver is installed.

  Configure CIM-IO servers as needed. The procedure for doing thismanually is described in the   Aspen Manufacturing Suite Advanced Process

Control Installation Guide. You can also use the Aspen Online Deployment

Desktop’s server configuration dialog. See the Aspen Online DeploymentDesktop help or details.

  Use the ADSA Client Config  Tool to establish public data sources for any

historians or data servers as needed.   Use the Online Deployment Desktop’s server configuration dialog to

configure authorization to control access to the online applications. See

the Desktop’s online help for details.

  Use the Online Deployment Desktop’s server configuration dialog tospecify I/O Servers corresponding to the CIM-IO, OPC, and Process Data

sources of interest.

  Enable the RTE service by selecting the Enable Server  check box in theserver configuration dialog.

Page 104: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 104/214

104 4 Individual Product Installation Notes

  If you use the Aspen Remote Simulation Server, change the service

properties of the Aspen Remote Simulation Server service to logon as the

Local System account and to interact with the desktop. This will ensurethat the maximum possible Windows resources are available to theprocess simulators.

Aspen Plus Installation Notes

Installation Details for Aspen Plus andAspen Properties

Installing the Aspen Properties EnterpriseDatabase

The AspenTech Installer looks for an existing SQL Server (2005, 2008, or SQL

Express 2005) installed on your computer. See the  Troubleshooting  sectionfor issues related to installing SQL Express.

Note: The server must be configured to  SQL Server and Windowsauthentication mode before you can use it with Aspen Plus. See "Configuring

Microsoft SQL Server or SQL Express."

  Verifying the Aspen Properties Enterprise Database Installation

  Verifying an Aspen Plus/Aspen Polymers Installation

  Using the FORTRAN Compiler with Aspen Plus

  Verifying the installation of the FORTRAN Compiler

  Troubleshooting Aspen Plus   Verifying an Aspen OLI Interface Installation

  Verifying an Aspen Distillation Synthesis feature of Aspen Plus Installation

At some sites, policy may prohibit the installation of SQL Server on individual

computers. In this case, the legacy databanks may be used or Aspen Plus

may be configured to use SQL Server on a designated computer.

To install Aspen Plus without installing a SQL Server:

1   On the Feature Selection screen, click the icon to the left of  ProcessModeling (Aspen Plus)  and select  This feature will be installed on

local hard drive.

2   Click the plus sign to open the suboptions under Process Modeling(Aspen Plus).

3   Click the icon to the left of  Local APED database and SQL  and select

This feature will not be available. The screen should not appear asfollows:

Page 105: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 105/214

4 Individual Product Installation Notes 105

Note: The Enterprise databases are installed on  C:\Documents andSettings\All Users\Application Data\AspenTech\APED V7.3  (orD:\Documents and Settings\All Users\Application

Data\AspenTech\APED V7.3). This location cannot be compressed or the

databases will not be installed. SQL server does not support databases oncompressed drives.

Aspen Properties Mobile Installation Notes

Aspen Properties Mobile consists of the following parts:

  Client app available on the App StoreSM

  Aspen Properties Mobile server running on IIS

  Aspen Properties

  Aspen Properties Enterprise Database (APED) server

  Sentinel License Manager providing licenses to Aspen Properties

Page 106: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 106/214

106 4 Individual Product Installation Notes

Aspen Properties Mobile depends on the Internet Information Server (IIS)

web server provided with Windows. IIS is not pre-installed on many Windowsinstallations. The steps for installing IIS vary based on the version of Windows, but typically you can install it from the  Add/Remove WindowsComponents section of the  Add or Remove Programs   control panel.

In addition, you need to obtain a server certificate for secure communication(https). Use the Web Server Certificate Wizard provided with IIS to install this

certificate.

IIS must be installed before you can install the Aspen Properties Mobile

Server.

Aspen Properties must be already installed on the Aspen Properties server.

The APED server can be the same one used throughout your company or canbe installed locally on the Aspen Properties server. The license server isnormally the same one used throughout your company.

The client for Aspen Properties Mobile is the free Aspen Properties Mobile app

available on the App Store on an iPad, iPhone 4, iPhone 3GS, iPhone 3G, the

original iPhone, or iPod touch.

Aspen OLI Interface Installation Notes

Note: The Aspen OLI Interface is a subcomponent of the Aspen Plus andAspen Properties installations and is installed automatically.

Aspen OLI Interface consists of two parts:   Aspen OLI Interface provided by AspenTech. The interface is included

with Aspen Plus and Aspen Properties and is provided without additionallicense.

  OLI Engine 8.2 in Aspen Plus V7.3 licensed by OLI Systems.

Existing customers of Aspen OLI are entitled to the OLI license automatically.However, new customers of Aspen OLI V7.3 will need to sign a contract with

OLI Systems. OLI Systems will provide the necessary software license

Page 107: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 107/214

4 Individual Product Installation Notes 107

manager, Hardlock security key, serial number, and password required to

access the OLI Engine in Aspen Plus.

Installation of Aspen OLI requires these steps:

1. Contact OLI Systems to obtain the OLI Hardlock security key and serial

number for installing the OLI Engine in Aspen Plus as part of the

continued licensing of Aspen OLI.2. Install the Aspen OLI Interface, which is part of the Process

Modeling (Aspen Plus) Installation. When this installation is complete,you will have installed all of the components required within the Aspen

framework to support the OLI Engine.

3. Install the OLI Engine in Aspen Plus V7.3 in order to complete theinstallation of Aspen OLI V7.3. A file named  OLI Engine in AspenPlus V7.3.exe  will be delivered when the Aspen OLI Interface is

installed (for example, to C:\Program Files\AspenTech\Aspen OLI

Interface V7.3). This is a self-extracting script that installs thecomponents supplied by OLI in a directory of your choosing (or the

default location C:\Program Files\OLI Systems\OLI Engine 8.2\Aspen

Plus V7.3.) During the installation, you will be asked to supply theserial number obtained in step 1.

4. Finally, plug in the OLI Hardlock key into an available USB port on

your system. It is recommended that you use the Security Settingsand Test   program accessible from the  Start | Programs | OLISystems | OLI Engine in Aspen Plus V7.3 | Tools  menu to confirm

that the OLI License is operating correctly.

Installing OLI Engine for Aspen Plus

Overview

The OLI Engine for Aspen Plus is a collection of utilities that help you prepareAspen Plus simulation models using OLI aqueous and mixed solvent

electrolytes (MSE) physical properties and equilibrium calculations.

OLI HardLock Security Key

You must have an OLI HardLock security key and serial number to enable

OLI’s license manager. Existing customers will automatically get the OLIHardLock security key and serial number as part of the continued licensing of Aspen OLI. If you do not have the key or serial number, contact OLI Systems

(973-539-4996).

Installing the HardLock Security Key

To install the HardLock security key

Attach the key to the parallel port located on the back of your computer.

  If you have the USB version of the HardLock key, attach it to any availableUSB connection.

Page 108: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 108/214

108 4 Individual Product Installation Notes

  If you have a parallel port version of the HardLock key, and you have a

printer connected to the parallel port, unplug your printer. Connect the

key, and then reconnect your printer to the HardLock key. The HardLockkey does not interfere with your printer.

Note: If you have a parallel port security key for another software product,

please make sure that the OLI HardLock key is connected directly to theparallel port and is first in the chain of keys.

OLI Engine in Aspen Plus

The OLI Engine uses InstallShield to lead you through a typical Windowsinstallation process. To complete the installation of Aspen OLI, you must

install the OLI Engine. This installation is available in two formats:

  A self-extracting executable file named  OLI Engine for Aspen PlusV7.3.exe  that is distributed on the Aspen DVD set and the OLI Systemswebsite.

  A product distribution DVD from OLI Systems.

Components

OLI Engine for Aspen Plus V7.3.exe  will install the following components:

  Chemistry Wizard. Used to prepare OLI chemistry model files and AspenPlus  .bkp  files.

  Data Locator. A utility for searching species in the OLI component

databanks.

  Chemistry Generator. The original utility for creating OLI chemistry

model files and the Aspen Plus  .bkp  files. The Chemistry Wizard has

replaced this utility.

  OLI security system for the OLI Property and Equilibrium CalculationEngine.

Installing

If you are installing the file  OLI Engine for Aspen Plus V7.3.exe  that has

been placed on in   C:\Program Files\AspenTech\Aspen OLI Interface

V7.3  as described in Step 3 above, proceed to Step 1, below.

Notes:  You can also download this .exe from the OLI Systems website. If you

already downloaded the file, then go to Step 1 below. If you have downloaded

the file yet, go to this site and follow the directions there to download:

http://support.olisystems.com

The .exe is also on the product DVD from OLI. If you have a product

distribution DVD provided by OLI, then insert the DVD and run  X:\setup.exe(where  X: is the drive letter for your DVD). Or, open Windows Explorer, locate

setup.exe and double-click on it. Go to Step 2 below.

1   Open Windows Explorer, and double-click on this self-extracting file.

2   On the Welcome  dialog box, click  Next.

Page 109: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 109/214

4 Individual Product Installation Notes 109

3   In the License Agreement  dialog box read the agreement, click  I

accept the terms in the License Agreement; then click  Next.

4   In the Customer Information  screen type your name and companyname. To complete the  Serial Number  field, you need the serial number

provided by OLI Systems. Click  Next.

5   In the  Configure Network License Server  dialog box Select

Automatic. Click  Next.

6   On the Choose Setup Type   screen, click  Typical  or   Custom. Most usersselect Typical. Click  Next.

Note: If you selected   Custom, the  Select Components  dialog box

appears. The default setting is to install all of the features (highly

recommended). If you are an experienced OLI user and you know thatyou do not want to use one or more of the optional databanks, then you

can clear them to save disk space.

7   On the Ready to Install   screen, click  Install.

The installation begins

HardLock Device Driver Installation Script

After the files are copied and the program group is populated, the HardLock

device driver installation script starts. This is a very brief installation, and youare not prompted for any information.

1   Read the screen and close any other programs if needed.2   Click  Next  to complete the installation. After the HardLock drivers are

installed, the InstallShield  Wizard Complete  screen appears.

3   Click Finish to exit the installation.

Page 110: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 110/214

110 4 Individual Product Installation Notes

Aspen Process ManualInstallation Notes

Server Configuration Notes:   Although you may be able to install the Process Manual on non-server

operating systems, these support a limited number of connections, so onlya few users will be able to access this system simultaneously.

  Security restrictions in service packs to Internet Explorer require the

domain name (typically the same as the machine name) to only includealphanumeric, “.” and “-” characters. In particular, the underscore

character is not permitted. If the domain name has other characters, then

cookies are not stored correctly and the Process Manual application willnot operate correctly.

Windows 2003   Make sure that the correct Windows components are installed; in

particular IIS and Active Server Pages (ASP), which are not installed by

default.

o   Start the Add/Remove Windows Components dialog.

o   Ensure that under Internet Information Services  that theInternet Information Services Snap-In and World Wide

Web Server   are installed.

Windows 2008   Make sure that the correct Windows components are installed; in

particular IIS and Active Server Pages (ASP), which are not installed bydefault. Using the Server Manager, ensure that the following are installed:

o   Roles:

  Web Server (IIS).

o   Role services:

  Web Server | Application development | ASP

  Management Tools | IIS 6 Management Compatibility.

Application Configuration

During installation, the Process Manual application will be configured on theURL:

http://server/AspenTech/ProMan

This will be associated with the web sub-folder in the Process Manual

installation.

  For improved performance, we recommend running the SLM Configuration

Wizard, selecting the Advanced settings and optimizing the licensing type.

Page 111: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 111/214

4 Individual Product Installation Notes 111

This will reduce the server time when checking licenses. Refer to the SLM

documentation for further details.

To complete the installation, the system must be configured and the newdocuments registered.

  To start this process, select the shortcut

o   Start | Programs| AspenTech | Aspen EngineeringProcess Manual V7.3

| Aspen Process Manual Administration

  This will display an administration page where some of the configurationoptions can be set.

Note: If the  administration  page fails to appear, with an HTTP Error 404message, check that you have configured IIS for Active Server Pages

(ASP). Also note that this is a different setting from ASP.NET.

  Contact configuration

o   Scroll down the page to the Intranet application settings

section.

o   You should enter some appropriate settings for the contactdetails, and click on the Update contact settings button.

o   The Performance and configuration section usually be left at thedefault values.

  Document registration

o   Scroll to the Document server settings section.

o   The search path indicates where the documents are stored on

the server; this should have been configured correctly during

installation.

o   However, you need to re-index the documents to make themavailable to the system, and to end users. To do this, click on

the Re-index documents button.o   You should see a list of documents appearing on the screen.

Indexing usually takes up to a minute.

o   When it is complete, click on the Return to administration page

button. To confirm that the process has worked, check that theTechnical area menu at the top left now has contents.

  Before using the web server, please ensure that you have configured theSoftware License Manager (SLM). We recommend specifying a named

license server to improve performance. Refer to the SLM documentation

for details on how to do this.

The system is now installed and ready for use.

Aspen Simulation WorkbookInstallation NotesAspen Simulation Workbook V7.3 is compatible with Aspen Plus V7.3, AspenHYSYS V7.3, and the various Aspen Modeler V7.3 products (ACM, Aspen Plus

Page 112: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 112/214

112

Dynamics, and s

products, from 2

Version C

Any two versionscannot coexist wi

previous versionuninstalled prior

It is possible to u

enabled within Edefault when Ex

Workbook AddOperation Sup

Workbook V7.3

DisablingTo disable AspenSimulation WorkManager dialog.

AspenInstall

AspenOptimiAspen Utilities OPlanner, Aspen

Online installatiodocument. Pleas

documentation.

4 Individual Product

on.). It is also compatible with earlier versi

006.5 to V7.2.

oexistence

of Aspen Simulation Workbook (and Aspenithin the same Excel Application. It is recom

of Aspen Simulation Workbook or Aspen OSto installing the current version.

se both versions on the same machine but o

cel at any given time. The version that willel starts and can be selected using the  Aspe

In Manager, which is available from the  Asort V7.3 (or Process Modeling V7 )| Aspen Si

Start  menu.

Add-in by DefaultSimulation Workbook, uncheck all versions oook that show up in the Aspen Simulation W

Utilities Plannertion Notes

Utilities On-Lineer Installation No

-Line Optimizer is a solution that consists of nline, and CIMIO. The Aspen Utilities Planner

n, configuration, and verification are outlinedrefer to the Aspen Manufacturing Suite DVD

Installation Notes

ns of these

SE Workbook)ended that

Workbook are

ly one may be

e run bySimulation

enTech |mulation

f Aspenorkbook Add-in

tesAspen Utilitiesand Aspen

in thisfor CIMIO

Page 113: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 113/214

4 Individual Product Installation Notes 113

Computer Configuration (Installation) Type

A Standard Install should normally be selected for Aspen Utilities Planner. TheServer Install does not contain all of the required Aspen Utilities Planner

features.

Microsoft Excel Interface Setup

To set up the Microsoft Excel interface to Aspen Utilities:

1 Start  Microsoft Excel 2003 or 2007.

2 For Excel 2003:

a On the menu bar, click  Tools | Add-Ins.

b On the  Add-Ins  dialog box, click  Browse  and navigate to the AspenUtilities Planner bin folder.

The default location is:

C:\Program Files\AspenTech\Aspen Utilities Planner V7.3\bin

c Click  Utilities240.xla; then  click  OK. In the  Add-Ins  dialog box,click  OK.

d When the confirmation dialog box appears, click OK.

3 For Excel 2007:

a Click the Office Button and then click Excel Options  at the bottom

b On the left menu, click  Add-Ins.

c In Manage: at the bottom select Excel Add-ins and click the Go  button.

d On the  Add-Ins  dialog box, click  Browse  and navigate to the AspenUtilities Planner  bin  folder.

The default location is:

C:\Program Files\AspenTech\Aspen Utilities Planner V7.3\bine Click  Utilities240.xla; then  click  OK. In the  Add-Ins  dialog box,

click  OK.

An Aspen Utilities item appears on the  Add-Ins  tab.

Page 114: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 114/214

114 4 Individual Product Installation Notes

Page 115: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 115/214

5 Verifying and ConfiguringAspen Products

OverviewGenerally speaking, to verify that the installation succeeded, you run theproduct you installed. However, some Aspen products have product-specific

verification procedures you should follow to verify that the application

installed correctly. In addition, some products have product-specificconfiguration requirements that must be met before the product can be run.

The following table lists all aspenONE   Aspen Engineering products, showing

whether they have product-specific verification or configuration procedures.

If the product does not have a product-specific verification procedure, simply

run the product to verify that it installed correctly.

Product Special

Verification

Special

Configuration

Aspen Adsorption V7.3 Yes No

Aspen Basic Engineering V7.3 Yes Yes

Aspen Batch Distillation V7.3 Yes No

Aspen Batch Process DeveloperV7.3

Yes Yes

Aspen Chromatography V7.3 Yes No

Aspen Custom Modeler V7.3 Yes No

Aspen Distillation Synthesis featurein Aspen Plus V7.3

Yes No

Aspen Economic Evaluation V7.3 No No

Aspen Energy Analyzer V7.3 No No

Aspen Exchanger Design and RatingV7.3

Aspen Shell & TubeExchanger V7.3

Aspen Air CooledExchanger V7.3

Aspen Fired Heater V7.3

Aspen Plate Exchanger V7.3

Yes Yes

Page 116: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 116/214

116   5  Verifying and Configuring Aspen Products

Product SpecialVerification

SpecialConfiguration

Aspen Plate Fin ExchangerV7.3

Aspen HTFS Research

Network V7.3Aspen Shell & Tube

Mechanical V7.3

Aspen Flare System Analyzer V7.3 No No

Aspen HTFS V7.3

Aspen MUSE V7.3

Yes No

Aspen HYSYS V7.3 Yes No

Aspen HYSYS Refining V7.3 Yes Yes

Aspen HYSYS Upstream V7.3 Yes No

Aspen Model Runner V7.3 No No

Aspen MUSE V7.3 Yes No

Aspen OnLine V7.3 Yes Yes

Aspen Online Deployment V7.3 No No

Aspen PIMS V7.3 No No

Aspen Plus V7.3 Yes Yes

Aspen Plus Dynamics V7.3 Yes No

Aspen Plus CatCracker V7.3 No Yes

Aspen Plus Hydrocracker V7.3 No Yes

Aspen Plus Hydrotreater V7.3 No Yes

Aspen Plus Reformer V7.3 No Yes

Aspen Polymers V7.3 Yes No

Aspen Process DevelopmentConsole V7.3 No No

Aspen Process Engineering ConsoleV7.3

No No

Aspen Process Manual V7.3 No No

Aspen Process Tools V7.3 No No

Aspen Properties V7.3 Yes Yes

Aspen Properties Mobile V7.3 Yes Yes

Aspen Reaction Modeler V7.3 No No

Aspen Remote Simulation ServiceV7.3

No Yes

Aspen Simulation Workbook V7.3 No No

Aspen Solubility Modeler V7.3 No Yes

Aspen Utilities On-Line Optimizer No No

Aspen Utilities Planner Yes No

Page 117: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 117/214

5 Verifying and Configuring Aspen Products 117

Aspen Products That Use Aspen Properties

Several Aspen Engineering products use Aspen Properties. The procedure forconfiguring and verifying an Aspen Properties installation is the same for each

product.

The following table shows the installation options that could result in the needto configure Aspen Properties. Following this table are the specific instructionsfor configuring and verifying an Aspen Properties installation.

Option Sub-Option

Process

Modeling(Aspen Plus)

ProcessModeling(Aspen Plus)

AdvancedSimulationOptions

ProcessModeling

(HYSYS)

AdvancedSimulation

OptionsExchangerDesign andRating

AspenProperties

ProcessDevelopment

Aspen BatchProcessDeveloper

ProcessDevelopment

AdvancedModelingOptions

Aspen PlusBasedRefinery

Reactors

APED

databasecomponent

The configuration and verification of the Aspen Properties Enterprise Databaseis described below.

Configuring Microsoft SQL Server or SQLExpress

Note: Aspen Properties Enterprise Database no longer uses Microsoft SQLServer Desktop Edition (MSDE) or MS SQL Server 2000 due to problemsencountered with these SQL servers.

In order to use the Aspen Properties Enterprise Database with correspondingAspen products (Aspen Plus, HYSYS, and so on.),  SQL 2005 SP3  is theminimum requirement as an install pre-requisite. Be sure to choose Mixed

Mode (in the Windows Authentication and SQL Server Authentication) during

the "authentication mode" step of the SQL Server installation. If you are not

Page 118: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 118/214

118   5  Verifying and Configuring Aspen Products

using mixed mode and have finished the Aspen installation, follow these steps

to ensure the mixed authentication mode is enabled.

For Microsoft SQL Server:

1   Run  Start | Programs | AspenTech |Process Modeling V7.3 | Aspen

Properties | Aspen Properties Database Configuration Tester.

2   Click   Start.  An "Incorrect SQL Engine Authentication Setting" dialogappears. Follow the instructions, then click  OK  and it will correct the

authentication setting to  Mixed  Mode for you.

For SQL Server Express, the user interface for configuring the server is not

installed by default. If you do not have it, download it from Microsoft:

http://www.microsoft.com/downloads/details.aspx?FamilyId=C243A5AE-4BD1-4E3D-94B8-5A0F62BF7796&displaylang=en and install it beforeperforming these steps:

1   Run  Start | Programs | Microsoft SQL Server 2005 | SQL ServerManagement Studio Express.

2   In the  Connect to Server  window, select the server name and  Windows

Authentication. Click  Connect.

3   In the  Microsoft SQL Server Management Studio Express  windowtree on the left, right-click the name of the server and click  Properties.

4   In the Server Properties  dialog, at the left, click  Security.

5   Under  Server authentication, select  SQL Server and Windowsauthentication mode, and click  OK.

6   In the object explorer, right-click the name of the server and selectRestart. The change will take effect after that.

Verifying the Aspen Properties Enterprise

Database Installation1   On the desktop, click Start | Programs | AspenTech | Process

Modeling V7.3 | Aspen Properties | Aspen Properties DatabaseConfiguration Tester.

2   When the Database Configuration Tester window appears, click  Start.

The tester will perform several tests and report the results.

  License availability: The tester verifies a license for Aspen Plus or Aspen

Properties is available.

  Configuration file permissions: The tester verifies that the configurationfile was installed with the correct permissions.

  SQL engine authentication settings: The tester reports all servers that

have at least one Aspen Properties database that is registered on thiscomputer. On the  localhost  line, it reports the authentication mode of the

local server and whether there is any problem with it. For other servers itcannot check this status, so it only reports what is required.

  Database access settings: The tester attempts to access each registered

database and performs three tests.

o   First, it verifies that it can connect to the database at all, witheither a  Connection Successful  message or a message

indicating the error that occurred.

Page 119: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 119/214

5 Verifying and Configuring Aspen Products 119

o   Next, it attempts to read the database as Aspen Plus or Aspen

Properties would do. This should report  Granted/Successful   if 

the database is configured for access from these programs, orDenied/Failed   otherwise. For a non-customized new installation,the databases APV73, NISTV73, and FACTV73 should all be

accessible.

o   Finally, it attempts to read the database as the DatabaseManager would do. This should also report  Granted/Successful 

or  Denied/Failed  based on the security options. For a non-customized new installation, the databases APV73, NISTV73,

and FACTV73 should all be accessible.

Aspen AdsorptionThis section contains the following:

  Verifying an Aspen Adsorption Installation

  Verifying an Aspen Adsorption Installation that uses Aspen Properties

Verifying an Aspen Adsorption Installation

Note: If you have not already done so, restart Windows to activate thechanges made to your configuration during the installation.

To verify the installation of Aspen Adsorption on a user PC

1   On the desktop, click Start | Programs | AspenTech | ProcessModeling V7.3 | Aspen Adsorption | Aspen Adsorption.

2   On the menu bar, click  File | Demonstrations.

The Demonstration Organizer  window opens.

3   In the top window, click Nitrogen production (single bed approach);then click Open.

A dialog box appears, indicating where the demonstration will be copied to

before automatically opening.

4   Click  OK.

5   In the top pane of the   Exploring – Simulation   window, click  Flowsheet.

6   In the lower pane, double-click Product_Comp.

A plot opens.

7   On the menu bar, click Run | Run.

After a few moments the dynamic run completes.8   On the Run complete  dialog box, click  OK.

The plot should display a result.

9   On the menu bar, click Tools | Report | Global Balances.

Additional messages should appear in the  Simulation Messages  window.

10  On the menu bar click  File | Exit.

11  When prompted to save changes, click  No.

Page 120: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 120/214

120   5  Verifying and Configuring Aspen Products

Aspen Adsorption closes.

You have successfully verified your installation. You can delete the test folder.

Verifying an Aspen Adsorption Installation

that Uses Aspen PropertiesNote: If you have not already done so, restart Windows to activate thechanges made to your configuration during the installation.

To verify an Aspen Adsorption installation that uses Aspen Properties:

1   On the desktop, click Start | Programs | AspenTech | Process

Modeling V7.3 | Aspen Adsorption | Aspen Adsorption.

2   On menu bar, click  File | Demonstrations.

The Demonstration Organizer  window opens.

3   In the top window, click Nitrogen production (single bed approach);

then click  Open.A dialog box appears, indicating where the demonstration will be copied to

before automatically opening.

4   Click  OK.

5   In the top pane of the   Exploring – Simulation  window, right click

Component Lists;  then, on the   shortcut  menu, click  Properties.

6   On the Component Properties Configuration  dialog box, verify that theProperties status is  Configured   using Embedded Aspen Properties.

The  Select Properties Definition File  dialog box appears.

7   Click  OK  to exit the  Physical Properties Configuration   dialog box.

8   In the top pane of the   Exploring – Simulation   window, click

Component Lists.9   In the lower pane, right-click on the item labeled Default. Click  Convert;

then, in the  Convert  dialog box, click  Yes.

The component list is converted for use with Aspen Properties.

10  Double click the component list  Default.

11  In the dialog box that appears, ensure the two components,  Nitrogen

and  Oxygen, are present in the right-hand list. Then click  Cancel.

12  To reconfigure the flowsheet for use with Aspen Properties, double click

any block on the flowsheet (for example  F1).

13  In the top pane of the   Exploring – Simulation   window, click  flowsheet.

14  In the lower pane, double-click  Product_Comp.

A plot opens.

15  On the menu bar, click  Run | Run.

After a few moments the dynamic run completes.

16  On the  Run complete  dialog box, click  OK.

The plot should display a result.

17  On the menu bar, click  Tools | Report | Global Balances.

Additional messages should appear in the simulation message window.

Page 121: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 121/214

5 Verifying and Configuring Aspen Products 121

18  On the menu bar click  File | Exit. When prompted to save changes, click

No.

Aspen Adsorption closes.

You have successfully verified your installation with Aspen Properties. You candelete the test folder.

Aspen Basic EngineeringThis section contains the following sections:

  Verifying an Aspen Basic Engineering Installation.

  Configuring Aspen Basic Engineering after Installation.

Verifying an Aspen Basic EngineeringInstallation

This verification procedure has two parts:

  Part One - Verifying Client-Server operation:

Proceeds to check client-server connectivity. This procedure assumes you

have a workspace created and connected to Microsoft Access or an RDBand are performing a  Server   install.

  Part Two - Verifying component installation:

Necessary to perform basic component installation checks withoutchecking client-server operation.

Verifying Client-Server Operation

This procedure checks client-server connectivity. Exit each component beforemoving to the next step.

At this stage, establishing client/server connectivity is sufficient to verifysuccessful installation. It is not necessary to modify existing diagrams ordatasheets.

Note: Before starting this procedure, ensure you have a valid username andpassword (or obtain one from your System Administrator); this allows you tolog on to the Workspace(s) you wish to connect to.

Logging On and Setting Up User Privileges

1   Log on to your PC with Administrator  privileges and start the Computer

Management control panel.

2   Under Services

Check that the  AZ162Broker  service is present and running.

If it is not running, check the  Properties/LogOn  settings to ensure theselected account exists and the password is correct.

3   Under Users and Groups

Ensure that everyone who is going to create workspaces is a member of the  Zyqad Administrators  group.

Page 122: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 122/214

122   5  Verifying and Configuring Aspen Products

4   Run the  Aspen Basic Engineering Administration  tool and check the

local privileges adding additional users and roles as required.

Connecting to a Workspace

5   On the desktop, click Start | Programs | AspenTech | Aspen BasicEngineering V7.3  to display the Aspen Basic Engineering list of installedcomponents.

6   Select  Explorer  to open the component.

The  Open Aspen Basic Engineering workspace  dialog appears.

7   Select a Workspace to log on to. The name of the selected Workspaceshould be displayed in the left pane of the main window.

8   Close the Explorer.

Opening a Diagram

9   On the desktop, click Start | Programs | AspenTech | Aspen Basic

Engineering V7.3   and select  Drawing Editor  to open the component.

The  Open Aspen Basic Engineering workspace  dialog appears.

10  Select a Workspace to log on to.

11  Select  File | Open, and select a diagram to open from the list displayed.

If none is listed, select  File | New   to create a new diagram and open it inthe main Drawing Editor window.

12  Close the Drawing Editor.

Opening a Datasheet

13  On the desktop, click  Start | Programs | AspenTech | Aspen BasicEngineering V7.3   and select Excel  Datasheet Editor   to open the

component.

The  Open Aspen Basic Engineering workspace  dialog appears.

14  Select a Workspace to log on to.

15  In Excel version 2003, select  Datasheet | Open Datasheet| by Type,for Excel versions 2007 and 2010 click the  Add-Ins  tab and select

Datasheet | Open Datasheet| by Type.   Make a selection from the list

displayed. Click  OK. The selected datasheet is displayed in theDatasheets dialog  New  tab.

16  Highlight the datasheet you have selected and click  Open. This opens the

datasheet in the Excel  Datasheet Editor  main window.

17   Close Excel.

Verifying Component InstallationThis procedure confirms each installed component opens without error and is

available to the user. Exit each component before moving to the next step.

Note: If any component fails to open, or an error message is displayed,inform your System Administrator.

Page 123: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 123/214

5 Verifying and Configuring Aspen Products 123

Logging On

1   Log on to your PC as a standard user (with no Administrator  privileges).

2   On the desktop, click Start | Programs | AspenTech | Aspen BasicEngineering V7.3  to display the Aspen Basic Engineering list of installed

components.

3   Next, move the cursor over the Configuration  option to displayConfiguration components.

4   Click the first component to open it and confirm it is available.

5   Repeat this procedure for the remaining Configuration  components,ensuring each component launches without error.

6   Next, move the cursor over the Interfaces  option to display  Interfacecomponents.

7   Click the first component to open it and confirm it is available.

8   Repeat this procedure for the remaining Interfaces  components,ensuring each component launches without error.

9   Next, open the following components individually ensuring each

component launches without error:

o   Datasheet Editor

o   Explorer

o   Drawing Editor

o   Excel Datasheet Editor

10  On the Windows  Start  menu, click  Start | Programs | Aspen BasicEngineering V7.3; then click Excel Datasheet Generator.

11  For Office 2003, confirm an additional menu item ( Generate) has been

added to the Excel menu bar. For Office 2007, confirm an additional menuitem (Generate) has been added to the Add-Ins tab. This appears onlywhen the  Excel Datasheet Generator  component has been opened.

You have verified the Aspen Basic Engineering installation.

Configuring Aspen Basic Engineering

Client Only

In general, no additional configuration requirements are necessary.

If the Aspen Basic Engineering client is connected to its server via a networkof limited bandwidth and poor performance of the graphics client is observed,we recommend that the flowsheet symbols be replicated to the local machine.

Please refer to the online Help,   Configuring Aspen Basic 

Engineering/Administration Tool/Managing Workspaces/Symbol Replicationtopics for details on symbol replication.

Standalone Access RDB Install

On 32-bit server installation, no additional configuration requirements are

necessary if using the default workspace. On 64-bit, you must use Oracle or

SQL RDB.

Page 124: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 124/214

124   5  Verifying and Configuring Aspen Products

Oracle or SQL RDB

Note: Only a correct and corresponding Oracle driver/client should be used in

conjunction with the Oracle server. See the notes on Oracle versions in Non-Aspen Software to ensure the same/correct driver and RDBMS version of 

Oracle is available and installed on your machine(s).

For Oracle or SQL RDB installations, the Zyqad Administrator must configurethe Workspace for RDB access.

Please refer to the online Help,   Configuring Aspen Basic Engineering

 /Administration Tool/Managing Workspaces topics, or the  Administrator Reference Manual, Managing Workspaces   for configuration details.

Note: If a server is used by the Drawing Editor client on remote machines,

the default symbol path will not work.

Aspen Batch DistillationThis section contains the instructions for verifying and configuring the AspenBatch Distillation installation.

Verifying an Aspen Batch DistillationInstallation1   Create an empty test folder and copy into it the file HeptHexOct.bspf .

The default directory location of the file is:

C:\Program Files\AspenTech\Aspen Batch DistillationV7.3\Examples\HeptHexOct

2   On the desktop, click Start | Programs | AspenTech | ProcessModeling V7.3 | Aspen Batch Distillation | Aspen Batch Distillation.

3   Click  File | Open, and select  HeptHexOct.bspf  from your test folder.

4   On the menu bar click  Run | Run.

After a few moments, the dynamic simulation starts to run.

5   Check that the time in the status bar at the bottom of the window isadvancing. The time appears after the words Dynamic at.

6   On the menu bar, click File | Exit.

A dialog box should appear with the message  This Will Stop The Current Simulation.

7   Click  OK.

8   When prompted to save changes, click No.

Aspen Batch Distillation closes.

You have successfully verified Aspen Batch Distillation.

Page 125: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 125/214

5 Verifying and Configuring Aspen Products 125

Aspen Batch Process DeveloperThis section contains the instructions for verifying and configuring the AspenBatch Process Developer installation.

Configuring Microsoft SQL Server or SQLExpress

Note: Aspen Properties Enterprise Database no longer uses Microsoft SQL

Server Desktop Edition (MSDE) or MS SQL Server 2000 due to problemsencountered with these SQL servers.

In order to use the Aspen Properties Enterprise Database with corresponding

Aspen products (Aspen Plus, HYSYS, and so on),  SQL 2005 SP3  is theminimum requirement as an install pre-requisite. Be sure to choose Mixed

Mode (in the Windows Authentication and SQL Server Authentication) duringthe "authentication mode" step of the SQL Server installation. If you are not

using mixed mode and have finished the Aspen installation, follow these stepsto ensure the mixed authentication mode is enabled.

For Microsoft SQL Server:

1   Run  Start | Programs | AspenTech |Process Modeling V7.3 | Aspen

Properties | Aspen Properties Database Configuration Tester.

2   Click   Start.  An "Incorrect SQL Engine Authentication Setting" dialogappears. Follow the instructions, then click  OK  and it will correct the

authentication setting to  Mixed  Mode for you.

For SQL Server Express, the user interface for configuring the server is not

installed by default. If you do not have it, download it from Microsoft:http://www.microsoft.com/downloads/details.aspx?FamilyId=C243A5AE-

4BD1-4E3D-94B8-5A0F62BF7796&displaylang=en and install it beforeperforming these steps:

1   Run  Start | Programs | Microsoft SQL Server 2005 | SQL Server

Management Studio Express.

2   In the  Connect to Server  window, select the server name and  Windows

Authentication. Click  Connect.

3   In the  Microsoft SQL Server Management Studio Express  window

tree on the left, right-click the name of the server and click  Properties.

4   In the Server Properties  dialog, at the left, click  Security.

5   Under  Server authentication, select  SQL Server and Windows

authentication mode, and click  OK.

6   In the object explorer, right-click the name of the server and selectRestart. The change will take effect after that.

Page 126: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 126/214

126   5  Verifying and Configuring Aspen Products

Verifying the Aspen Properties EnterpriseDatabase Installation1   On the desktop, click Start | Programs | AspenTech | Process

Modeling V7.3 | Aspen Properties | Aspen Properties Database

Configuration Tester.

2   When the Database Configuration Tester window appears, click  Start.

The tester will perform several tests and report the results.

  License availability: The tester verifies a license for Aspen Plus or Aspen

Properties is available.

  Configuration file permissions: The tester verifies that the configuration

file was installed with the correct permissions.

  SQL engine authentication settings: The tester reports all servers thathave at least one Aspen Properties database that is registered on this

computer. On the  localhost  line, it reports the authentication mode of thelocal server and whether there is any problem with it. For other servers it

cannot check this status, so it only reports what is required.

  Database access settings: The tester attempts to access each registereddatabase and performs three tests.

o   First, it verifies that it can connect to the database at all, with either a

Connection Successful  message or a message indicating the error thatoccurred.

o   Next, it attempts to read the database as Aspen Plus or Aspen

Properties would do. This should report  Granted/Successful  if the

database is configured for access from these programs, orDenied/Failed  otherwise. For a non-customized new installation, thedatabases APV72, NISTV72, and FACTV72 should all be accessible.

o   Finally, it attempts to read the database as the Database Manager

would do. This should also report  Granted/Successful  or  Denied/Failed based on the security options. For a non-customized new installation,

the databases APV72, NISTV72, and FACTV72 should all be accessible.

Aspen Chromatography

Verifying an Aspen ChromatographyInstallation

Note: If you have not already done so, restart Windows to activate thechanges made to your configuration during the installation.

To verify an Aspen Chromatography Installation

1   On the desktop, click Start | Programs | AspenTech | ProcessDevelopment V7.3 | Aspen Chromatography | Aspen

Chromatography.

2   On the menu bar, click  File | Demonstrations.

Page 127: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 127/214

5 Verifying and Configuring Aspen Products 127

The Demonstration Organizer  window opens.

3   In the top window, select Separation of D- and L- Threonine

enantiomers and click  Open.

A dialog box appears, indicating where the demonstration will be copied to

before automatically opening.

4   Click  OK.5   In the top pane of the   Exploring – Simulation   window, click  flowsheet.

6   In the lower pane, double-click Axial- Concentration.

A plot opens.

7   On the menu bar click  Run | Run.

After a few moments the dynamic run completes.

8   On the Run complete  dialog box, click  OK.

The plot should display a result.

9   On the menu bar, click Tools | Report | Chromatography Report.

A chromatography report dialog box appears.

10  On the menu bar click  File | Exit. When prompted to save changes, click

No.

Aspen Chromatography closes.

You have now successfully verified your installation. You can delete the testfolder created earlier.

Aspen Custom ModelerThis section contains the instructions for verifying the installation of Aspen

Custom Modeler on user PCs.

Verifying the Server Installation

Applies to: Aspen Adsorption, AspenChromatography, and Aspen Plus Dynamics

After you have installed and configured the simulation server software on theserver for any Aspen Modeler product, ensure that the installation is working

correctly.

To verify the server installation

1   On the desktop of the server computer, click Start | Run.

2   Enter the following command:

 pathname\sim_server.exe

where:

 pathname is the directory location of the file.

Page 128: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 128/214

128   5  Verifying and Configuring Aspen Products

The default location is:

C:\Program Files\AspenTech\AMSystem V7.3\bin\ sim_server.exe

Note: If your path contains spaces, as in the default path, enclose the

command in quotes.

3   Click  OK:A message similar to the following indicates a successful verification:

sim_server.exe (Version 23.0) built on Nov 5 2008 at 17:40:23

Verifying an Aspen Custom ModelerInstallation

Note: If you have not already done so, restart Windows to activate the

changes made to your configuration during the installation.

To verify an installation of Aspen Custom Modeler on a user PC1   Create an empty test folder and copy the FiveTank.acmf   file into it. The

default location of this file is:

C:\Program Files\AspenTech\Aspen Custom ModelerV7.3\Examples\5Tank

2   On the desktop, click Start | Programs | AspenTech | Process

Modeling V7.3 | Aspen Custom Modeler | Aspen Custom Modeler.

3   On the menu bar, click File | Open.

4   Navigate to your test folder and click the Fivetank.acmf  file; then click

Open to load the simulation.

5   On the menu bar, click Run | Mode | Dynamic.

6   On the menu bar, click Run | Run.

After a few moments the dynamic simulation starts to run.

7   Ensure that the time displayed in the status bar at the bottom of thewindow is advancing.

The time appears after the words  Dynamic at.

8   On the menu bar click  File | Exit.

9   When the This will stop the current simulation   message appears, clickOK.

10  When prompted to save changes, click  No.

Aspen Custom Modeler closes.

You have successfully verified your installation. You can delete the test folder.

Verifying an Aspen Custom ModelerInstallation with Aspen Properties

You verify an Aspen Custom Modeler installation that uses Aspen Properties

by following two steps:

Page 129: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 129/214

5 Verifying and Configuring Aspen Products 129

1   In   Aspen Plus, create an Aspen Plus .appdf   file

2   In   Aspen Custom Modeler,  run the  absorber example  simulation.

Step 1: Creating the Aspen Plus ProblemDefinition (.appdf) file

To create the Aspen Plus problem definition file

1   If you have not already done so, restart Windows to activate the changes

made to your configuration during the installation.

2   Create an empty test folder and copy into it the files from the  Absorber

folder. The default location of this folder is:

C:\Program Files\AspenTech\Aspen Custom ModelerV7.3\Examples\Absorber

3   On the desktop, click Start | Programs | AspenTech | Process

Modeling V7.3 | Aspen Plus| Aspen Plus User Interface.

4   In the Aspen Plus Startup  dialog box, open the  Absorber.bkp  file inyour test folder.

Note: There is no flowsheet because this is a properties-only input file.

5   On the Aspen Plus menu bar, click Run | Run.

6   After the run completes, on the menu bar click File | Export. In theSave As type field, select Problem Definition File (*.appdf) fromthe list  and save in your test folder as an Aspen Plus problem definition

(.appdf ) file.

7 Exit   Aspen Plus.

Step 2: Running the Absorber Example SimulationTo run the absorber example simulation in Aspen Custom Modeler:

1   On the desktop, click Start | Programs | AspenTech | Process

Modeling V7.3 | Aspen Custom Modeler V7.3 | Aspen CustomModeler.

2   On the menu bar, click File | Open. Locate your test folder and select the

absorber.acmf  file. Then click  Open.

3   In the All Items  pane of the  Simulation Explorer, click  Flowsheet  toselect it.

4   In the  Contents of Simulation   pane, double-click the  FeedDisturbance

task to activate it.

5   In the  Contents of Simulation   pane, double-click  TempProfile  to

display the temperature profile plot.

6   In the  Contents of Simulation   pane, double-click the

InitializeSimulation script to run it.

When the script completes, the temperature profile plot displays the result.

7   On the menu bar, click File | Exit.

8   When prompted to save changes, click No.

Page 130: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 130/214

130   5  Verifying and Configuring Aspen Products

Aspen Custom Modeler closes.

You have successfully verified your installation. You can delete the test folder.

Aspen Exchanger Design andRating

Verifying an Aspen Exchanger Design and

Rating Installation

Note: If you have not already done so, restart Windows to activate the

changes made to your configuration during the installation.

To verify the installation of any of the Aspen Exchanger Design and

Rating V7.3 design system products on a user PC:1   On the desktop, click Start | Programs | AspenTech | Aspen

Exchanger Design and Rating V7.3 | Aspen Exchanger Design andRating User Interface.

The  Aspen Exchanger Design and Rating  window appears.

2   On the  Aspen Exchanger Design and Rating  dialog box, click the

Existing tab.

3   Double-click the  More Files  folder and then navigate to < X >:\ProgramFiles\AspenTech\Aspen Exchanger Design and Rating

V7.3\Examples. You will see folders for the various products within

Exchanger Design and Rating. Open one of the folders and open any of its

files.4   On the menu bar, click the Run  ( ) button.

5   If the following message appears: "No change has been made to the file.Do you still want to run?". Click  Yes.

The program should open the status window and display the calculation

progress.

You are finished with the verification of the Aspen  Exchanger Design and

Rating  installation.

You are finished with the verification of the Aspen  Exchanger Design andRating  installation.

In order to use the Aspen Properties Enterprise Database with Aspen Plus orAspen Properties, a SQL server is required.

Page 131: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 131/214

5 Verifying and Configuring Aspen Products 131

Configuring Microsoft SQL Server or SQLExpress

Note: Aspen Properties Enterprise Database no longer uses Microsoft SQL

Server Desktop Edition (MSDE) or MS SQL Server 2000 due to problems

encountered with these SQL servers.

In order to use the Aspen Properties Enterprise Database with corresponding

Aspen products (Aspen Plus, HYSYS, and so on),  SQL 2005 SP3  is theminimum requirement as an install pre-requisite. Be sure to choose Mixed

Mode (in the Windows Authentication and SQL Server Authentication) duringthe "authentication mode" step of the SQL Server installation. If you are not

using mixed mode and have finished the Aspen installation, follow these steps

to ensure the mixed authentication mode is enabled.

For Microsoft SQL Server:

1   Run  Start | Programs | AspenTech |Process Modeling V7.3 | AspenProperties | Aspen Properties Database Configuration Tester.

2   Click   Start.  An "Incorrect SQL Engine Authentication Setting" dialogappears. Follow the instructions, then click  OK  and it will correct theauthentication setting to  Mixed  Mode for you.

For SQL Server Express, the user interface for configuring the server is notinstalled by default. If you do not have it, download it from Microsoft:http://www.microsoft.com/downloads/details.aspx?FamilyId=C243A5AE-4BD1-4E3D-94B8-5A0F62BF7796&displaylang=en and install it before

performing these steps:

1   Run  Start | Programs | Microsoft SQL Server 2005 | SQL ServerManagement Studio Express.

2   In the  Connect to Server  window, select the server name and  Windows

Authentication. Click  Connect.

3   In the  Microsoft SQL Server Management Studio Express  window

tree on the left, right-click the name of the server and click  Properties.

4   In the Server Properties  dialog, at the left, click  Security.

5   Under  Server authentication, select  SQL Server and Windowsauthentication mode, and click  OK.

6   In the object explorer, right-click the name of the server and select

Restart. The change will take effect after that.

Verifying the Aspen Properties EnterpriseDatabase Installation1   On the desktop, click Start | Programs | AspenTech | Process

Modeling V7.3 | Aspen Properties | Aspen Properties Database

Configuration Tester.

2   When the Database Configuration Tester window appears, click  Start.

The tester will perform several tests and report the results.

  License availability: The tester verifies a license for Aspen Plus or Aspen

Properties is available.

Page 132: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 132/214

132   5  Verifying and Configuring Aspen Products

  Configuration file permissions: The tester verifies that the configuration

file was installed with the correct permissions.

  SQL engine authentication settings: The tester reports all servers thathave at least one Aspen Properties database that is registered on this

computer. On the  localhost  line, it reports the authentication mode of thelocal server and whether there is any problem with it. For other servers it

cannot check this status, so it only reports what is required.

  Database access settings: The tester attempts to access each registered

database and performs three tests.

o   First, it verifies that it can connect to the database at all, with either a

Connection Successful  message or a message indicating the error that

occurred.

o   Next, it attempts to read the database as Aspen Plus or Aspen

Properties would do. This should report  Granted/Successful  if the

database is configured for access from these programs, orDenied/Failed  otherwise. For a non-customized new installation, thedatabases APV73, NISTV73, and FACTV73 should all be accessible.

o  Finally, it attempts to read the database as the Database Managerwould do. This should also report  Granted/Successful  or  Denied/Failed 

based on the security options. For a non-customized new installation,

the databases APV73, NISTV73, and FACTV73 should all be accessible.

Aspen HYSYS

Verifying an Aspen HYSYS Installation

Note: If you have not already done so, restart Windows to activate the

changes made to your configuration during the installation.Aspen HYSYS: For Windows Vista Users: Navigate to < X >:\Program

Files\AspenTech\Aspen HYSYS V7.3\Samples  and copy the sample filesto a user-writeable folder.

Aspen HYSYS Upstream: For Windows Vista Users: Navigate to< X >:\Program Files\AspenTech\Aspen HYSYS

V7.3\Samples\AspenHydraulics\Single Phase  and copy the files to auser-writeable folder.

To verify the installation of Aspen HYSYS V7.3 on a user PC:

1   On the desktop, click Start | Programs | AspenTech | Process

Modeling V7.3 | Aspen HYSYS | Aspen HYSYS.

The Aspen HYSYS V7.3 program  window appears.

2   Click the Open Case  icon on the Aspen HYSYS toolbar.

Follow these steps to verify an Aspen HYSYS Installation:

3   Navigate to the  Samples  folder (or, alternatively, to the folder created forWindows Vista users), and open the Aspen HYSYS sample case namedTutor1. Open  Mix-100.  Select and then clear the  Ignore  checkbox and

verify that the simulation converges correctly

Page 133: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 133/214

5 Verifying and Configuring Aspen Products 133

4   In the flowsheet, double click the component Mix-100.  In the  Properties

dialog, select and then clear the  Ignore  check box. In the message panel,

verify that the simulation converges correctly.

5   Close the case.

Verifying an Aspen HYSYS UpstreamInstallation

To verify the installation of Aspen HYSYS Upstream V7.3 on a user PC:

1   Navigate to the  Samples\AspenHydraulics\Single Phase   folder (or,

alternatively, to the folder created for Windows Vista users) and openmixer.hsc. Verify that the network in the hydraulics subflowsheetconverges.

2 Close the case.

3 Navigate to the Sample\AspenHydraulics\Single Phase folder and

open mixer dynamic.hsc.

4   Click   Continue  to restart the integrator. Click  No on the Dynamic

Assistant warning and verify that the integrator runs without errors orwarnings (see bottom left end of the status bar).

5   Close the case.

Verifying an Aspen HYSYS PetroleumRefining Installation

To verify an Aspen HYSYS Refining and Aspen HYSYS-based refineryreactor installation:

Note: The refining reactor functionality requires you to install Aspen HYSYS(Advanced) from the install selection.

1   On the File  menu, click  Open; then click  Reformer.

2   Navigate to the  \Template  folder and open4BedSemiRegenWithStabilizer-Reformer.Cat.

3   Double click Reactor Section; then select and then clear the  Ignorecheck box.

4   In the message panel, verify that the simulation converges.

5   Close the case.

6   On the File  menu, click  Open; then click  Hydrocracker.

7   Navigate to the  \Template  folder and open  Simple.hcr.

8   Double click Reactor Section; then select and then clear the  Ignore

check box.

9   In the message panel, verify that the simulation converges.

10  Close the case.

11  On the  File  menu, click  Open; then click  FCC.

12  Navigate to the  \Template  folder and open  one_riser.fcc.

Page 134: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 134/214

134   5  Verifying and Configuring Aspen Products

13  Double click  Reactor Section; then select and then clear the  Ignore

check box.

14  In the message panel, verify that the simulation converges.

15  Close the case.

Configuring Microsoft SQL Server or SQLExpress

Note: Aspen Properties Enterprise Database no longer uses Microsoft SQL

Server Desktop Edition (MSDE) or MS SQL Server 2000 due to problems

encountered with these SQL servers.

In order to use the Aspen Properties Enterprise Database with corresponding

Aspen products (Aspen Plus, HYSYS, and so on),  SQL 2005 SP3  is the

minimum requirement as an install pre-requisite. Be sure to choose MixedMode (in the Windows Authentication and SQL Server Authentication) duringthe "authentication mode" step of the SQL Server installation. If you are not

using mixed mode and have finished the Aspen installation, follow these stepsto ensure the mixed authentication mode is enabled.

For Microsoft SQL Server:

1   Run  Start | Programs | AspenTech |Process Modeling V7.3 | Aspen

Properties | Aspen Properties Database Configuration Tester.

2   Click   Start.  An "Incorrect SQL Engine Authentication Setting" dialog

appears. Follow the instructions, then click  OK  and it will correct theauthentication setting to  Mixed  Mode for you.

For SQL Server Express, the user interface for configuring the server is notinstalled by default. If you do not have it, download it from Microsoft:http://www.microsoft.com/downloads/details.aspx?FamilyId=C243A5AE-

4BD1-4E3D-94B8-5A0F62BF7796&displaylang=en and install it beforeperforming these steps:

1   Run  Start | Programs | Microsoft SQL Server 2005 | SQL ServerManagement Studio Express.

2   In the  Connect to Server  window, select the server name and  WindowsAuthentication. Click  Connect.

3   In the  Microsoft SQL Server Management Studio Express  window

tree on the left, right-click the name of the server and click  Properties.

4   In the Server Properties  dialog, at the left, click  Security.

5   Under  Server authentication, select  SQL Server and Windowsauthentication mode, and click  OK.

6   In the object explorer, right-click the name of the server and selectRestart. The change will take effect after that.

Page 135: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 135/214

5 Verifying and Configuring Aspen Products 135

Verifying an Aspen HYSYS PetroleumRefining Installation

To verify an Aspen HYSYS Refining and Aspen HYSYS-based refinery

reactor installation:

Note: The refining reactor functionality requires you to install Aspen HYSYS

(Advanced) from the install selection.

1   On the File  menu, click  Open; then click  Reformer.

2   Navigate to the  \Template  folder and open

4BedSemiRegenWithStabilizer-Reformer.Cat.

3   Double click Reactor Section; then select and then clear the  Ignorecheck box.

4   In the message panel, verify that the simulation converges.

5   Close the case.

6   On the File  menu, click  Open; then click  Hydrocracker.

7   Navigate to the  \Template  folder and open  Simple.hcr.

8   Double click Reactor Section; then select and then clear the  Ignore

check box.

9   In the message panel, verify that the simulation converges.

10  Close the case.

11  On the  File  menu, click  Open; then click  FCC.

12  Navigate to the  \Template  folder and open  one_riser.fcc.

13  Double click  Reactor Section; then select and then clear the  Ignore

check box.

14  In the message panel, verify that the simulation converges.

15  Close the case.

Configuring Microsoft SQL Server or SQL

Express

In order to use the Aspen Properties Enterprise Database with Aspen Plus orAspen Properties, a SQL server is required.

Note: Aspen Properties Enterprise Database no longer uses Microsoft SQL

Server Desktop Edition (MSDE) or MS SQL Server 2000 due to problems

encountered with these SQL servers.

On Microsoft SQL Server:1   Run  Start | Programs | Microsoft SQL Server | Enterprise Manager.

2   In the tree on the left, right-click the name of the server and selectProperties. The   SQL Server Properties (Configure)  dialog box

appears.

3   Click the Security tab.

4   Under  Authentication, select  SQL Server and Windows, and click  OK.

Page 136: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 136/214

136   5  Verifying and Configuring Aspen Products

On SQL Server Express, the user interface for configuring the server is not

installed by default. If you do not have it, download it from Microsoft:

http://www.microsoft.com/downloads/details.aspx?FamilyId=C243A5AE-4BD1-4E3D-94B8-5A0F62BF7796&displaylang=en and install it beforeperforming these steps:

5   Run  Start | Programs | Microsoft SQL Server 2005 | SQL Server

Management Studio Express.

The Connect to Server  window appears.

6   Select the server name and Windows Authentication. Click   Connect.The  Microsoft SQL Server Management Studio Express  window

appears.

7   In the tree on the left, right-click the name of the server and selectProperties. The  Server Properties dialog box appears.

8   At the left, click Security.

9   Under  Server authentication, select  SQL Server and Windowsauthentication mode, and click  OK.

Verifying the Aspen Properties EnterpriseDatabase Installation1   On the desktop, click Start | Programs | AspenTech | Process

Modeling V7.3 | Aspen Properties | Aspen Properties DatabaseConfiguration Tester.

2   When the Database Configuration Tester window appears, click  Start.

The tester will perform several tests and report the results.

  License availability: The tester verifies a license for Aspen Plus or AspenProperties is available.

  Configuration file permissions: The tester verifies that the configuration

file was installed with the correct permissions.

  SQL engine authentication settings: The tester reports all servers thathave at least one Aspen Properties database that is registered on this

computer. On the  localhost  line, it reports the authentication mode of the

local server and whether there is any problem with it. For other servers itcannot check this status, so it only reports what is required.

  Database access settings: The tester attempts to access each registered

database and performs three tests.

o   First, it verifies that it can connect to the database at all, with either aConnection Successful  message or a message indicating the error that

occurred.

o   Next, it attempts to read the database as Aspen Plus or AspenProperties would do. This should report  Granted/Successful  if the

database is configured for access from these programs, or

Denied/Failed  otherwise. For a non-customized new installation, thedatabases APV73, NISTV73, and FACTV73 should all be accessible.

o   Finally, it attempts to read the database as the Database Managerwould do. This should also report  Granted/Successful  or  Denied/Failed 

based on the security options. For a non-customized new installation,the databases APV73, NISTV73, and FACTV73 should all be accessible.

Page 137: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 137/214

5 Verifying and Configuring Aspen Products 137

Aspen MUSE

Verifying an Aspen MUSE Installation

Note: If you have not already done so, restart Windows to activate thechanges made to your configuration during the installation.For Windows Vista Users: Navigate to:   < X >:\Program

Files\AspenTech\HTFS\Aspen MUSE V7.3\Examples, and copy all examplefiles to a user-writeable folder.

To verify the installation of the Aspen MUSE V7.3 design product on a

user PC

1   On the desktop, click Start | Programs | AspenTech | Exchanger

Design and Rating V7.3 | Heritage Design Tools | Aspen MUSE |Aspen MUSE.

The  Aspen MUSE V7.3 program  window appears.2   On the Aspen MUSE  dialog box, click the  Existing  button.

3   Navigate to your user-writable folder (see note above), and open any of 

the files.

4   On the menu bar click  Run | Calculate All.

The program should run and provide the Results Summary.

You are now finished with the verification of the Aspen MUSE installation.

Aspen OnLineThis section contains the following sections:

  Configuring Aspen OnLine

  Verifying an Aspen OnLine Installation

Note: If you have an older version of Aspen OnLine installed, see "AspenOnLine," which explains how to back up your existing files so you don’t lose

your work.

Configuring Aspen OnLine

When the installation of Aspen OnLine is complete, you must configure:

  Aspen OnLine Server

  Aspen OnLine Client

Configuring CIM-IO for the Aspen OnLine Server

The CIM-IO component for Aspen OnLine must be configured to communicatewith the source of plant data.

Page 138: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 138/214

138   5  Verifying and Configuring Aspen Products

Note: If another AspenTech application on this computer is using CIM-IO to

communicate with the same devices, Aspen OnLine will use the same CIM-IO

connection, and you do not need to perform this configuration.

The following instructions assume the plant data server is IP.21. For complete

CIM-IO configuration instructions for IP.21 and for all other plant data serverdevices, see the CIM-IO manual.

Adding Services

To add services to the Windows server computer:

1   In Windows Notepad (or other text editor), open the  services  file. The

default location is:

C:\winnt\system32\drivers\etc\services

2   Insert the following two lines so that all services are in numerical order:

If necessary, replace 5801 and 5802 with unused service numbers greaterthan 1023 that are identical to those in the corresponding file in the IP.21

server computer.

CIMIOSETCIM_200 5801/tcp #CIMIO for IP.21CIMIOSETCIMH_200 5802/tcp #CIMIO for IP.21 historical

3   Save the file and exit the text editor.

Specifying Logical Devices

To specify the Logical Devices used by CIM-IO in its logical devicedefinition file:

1   Double click the  CIM-IO Device Configuration   icon in the  CIM-IO

windows group.-or-On the desktop, click  Start | Programs | AspenTech | AspenManufacturing Suite - Information Mgmt | Cim-io | Logical

Devices.

The header line reads:

Logical Device Name Node Name DLGP Service Name

2   Insert the following line as the last line in the file:

IOSETCIM200   NodeName   CIMIOSETCIM_200 CIMIOSETCIMH_200

where:

NodeName is the server name of the computer where IP.21 resides.

Note: These instructions assume the plant data server is IP.21. For yourspecific device or plant data server, see the CIM-IO manual.

Page 139: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 139/214

5 Verifying and Configuring Aspen Products 139

Verifying an Aspen OnLine Installation

Perform the following steps to verify that Aspen OnLine is installed andfunctional.

1   Verify plant data access on the server machine.

2   Verify relevant Aspen products on the server machine.

3   Verify Aspen OnLine on the server and client machines.

Verifying Plant Data Access

To verify plant data access on the server machine, follow the instructions in “The CIM-IO Test Utility” section of the  Aspen OnLine User Guide.

Verifying Aspen Products

Aspen OnLine can drive Aspen Plus models and models from Aspen CustomModeler and related products such as Aspen Utilities.

  If Aspen OnLine V7.3 is used to drive Aspen Plus models, verify thatAspen Plus V7.3 has been correctly installed on the server machine.

  If Aspen OnLine V7.3 is used to drive Aspen Custom Modeler and related

product models, verify that Version V7.3 of the corresponding AspenCustom Modeler products has been installed properly.

Verifying Aspen OnLine

To verify Aspen OnLine on the server machine:

Server Machine

1   Go to the installed Aspen OnLine V7.3 product folder and copy thesubfolder, AOLSample, to a location under one of the local drives on the

server machine.

2   On the desktop, click Start | Programs | AspenTech | Aspen OnLine V7.3 |

Aspen OnLine Project Manager .

The  Aspen OnLine Project Manager  window appears.

3   For  Computer  enter the name of the server machine.

-or-Use the  Browse  button to locate the server machine name.

4   Click  Register.

5   On the dialog box, enter the path to the AOLSample  folder (step 1). Forexample:

D:\AspenTech\AspenOnLine\AOLSample

The new project name appears in the list in the  Aspen OnLine ProjectManager window.

6   Click  OK  to register the sample project and close the dialog box.

7   Click  Close  to exit the Project Manager.

Page 140: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 140/214

140   5  Verifying and Configuring Aspen Products

8   On the desktop, click Start | Programs | AspenTech | Aspen OnLine V7.3 |

Aspen OnLine Client GUI.

The  Aspen OnLine  window appears.

9   On the  Aspen OnLine Startup  dialog box,

o   Specify the   Server name  (Step 3)

o   Select  AOLSample  as project name.

10  Click  OK.

11  Perform offline to online for both models in the project.

12  In the  Steady-state detection   frame, click  Load.

13  After the program is loaded, click  Start.

14  In the frame on the right, do the same to start the Aspen OnLine engine.

Aspen OnLine is running.

Client Machine

To verify Aspen OnLine on the client machine:1   On the desktop, click Start | Programs | AspenTech | Aspen

Engineering | Aspen OnLine V7.3 | Project Client GUI.

The  Aspen OnLine  window appears.

2   On the  Aspen OnLine Startup  dialog box, specify the server name andproject name.

3   Click  OK.

4   Make sure that Aspen OnLine is running on the server machine.

5   On the Aspen OnLine  menu bar, click  Data | Data Browser.

The Data Browser  window appears.

The information displayed in the Data Browser should reflect the projectinformation for the specified project on the specified server machine.

Aspen PlusThis chapter contains the following sections:

  Configuring Microsoft SQL Server or SQL Express

  Verifying the Aspen Properties Enterprise Database Installation

  Verifying an Aspen Plus/Aspen Polymers Installation

  Using the FORTRAN Compiler with Aspen Plus

  Verifying the installation of the FORTRAN Compiler

  Troubleshooting Aspen Plus

  Verifying an Aspen OLI Interface Installation

  Verifying an Aspen Distillation Synthesis feature of Aspen Plus Installation

Page 141: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 141/214

5 Verifying and Configuring Aspen Products 141

Configuring Microsoft SQL Server or SQLExpress

Note: Aspen Properties Enterprise Database no longer uses Microsoft SQL

Server Desktop Edition (MSDE) or MS SQL Server 2000 due to problems

encountered with these SQL servers.

In order to use the Aspen Properties Enterprise Database with corresponding

Aspen products (Aspen Plus, HYSYS, and so on),  SQL 2005 SP3  is theminimum requirement as an install pre-requisite. Be sure to choose Mixed

Mode (in the Windows Authentication and SQL Server Authentication) duringthe "authentication mode" step of the SQL Server installation. If you are not

using mixed mode and have finished the Aspen installation, follow these steps

to ensure the mixed authentication mode is enabled.

For Microsoft SQL Server:

1   Run  Start | Programs | AspenTech |Process Modeling V7.3 | AspenProperties | Aspen Properties Database Configuration Tester.

2   Click   Start.  An "Incorrect SQL Engine Authentication Setting" dialogappears. Follow the instructions, then click  OK  and it will correct theauthentication setting to  Mixed  Mode for you.

For SQL Server Express, the user interface for configuring the server is notinstalled by default. If you do not have it, download it from Microsoft:http://www.microsoft.com/downloads/details.aspx?FamilyId=C243A5AE-4BD1-4E3D-94B8-5A0F62BF7796&displaylang=en and install it before

performing these steps:

1   Run  Start | Programs | Microsoft SQL Server 2005 | SQL ServerManagement Studio Express.

2   In the  Connect to Server  window, select the server name and  Windows

Authentication. Click  Connect.

3   In the  Microsoft SQL Server Management Studio Express  window

tree on the left, right-click the name of the server and click  Properties.

4   In the Server Properties  dialog, at the left, click  Security.

5   Under  Server authentication, select  SQL Server and Windowsauthentication mode, and click  OK.

6   In the object explorer, right-click the name of the server and select

Restart. The change will take effect after that..

Verifying the Aspen Properties EnterpriseDatabase Installation1   On the desktop, click Start | Programs | AspenTech | Process

Modeling V7.3 | Aspen Properties | Aspen Properties Database

Configuration Tester.

2   When the Database Configuration Tester window appears, click  Start.

The tester will perform several tests and report the results.

  License availability: The tester verifies a license for Aspen Plus or Aspen

Properties is available.

Page 142: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 142/214

142   5  Verifying and Configuring Aspen Products

  Configuration file permissions: The tester verifies that the configuration

file was installed with the correct permissions.

  SQL engine authentication settings: The tester reports all servers thathave at least one Aspen Properties database that is registered on this

computer. On the  localhost  line, it reports the authentication mode of thelocal server and whether there is any problem with it. For other servers it

cannot check this status, so it only reports what is required.

  Database access settings: The tester attempts to access each registered

database and performs three tests.

o   First, it verifies that it can connect to the database at all, with either a

Connection Successful  message or a message indicating the error that

occurred.

o   Next, it attempts to read the database as Aspen Plus or Aspen

Properties would do. This should report  Granted/Successful  if the

database is configured for access from these programs, orDenied/Failed  otherwise. For a non-customized new installation, thedatabases APV73, NISTV73, and FACTV73 should all be accessible.

o  Finally, it attempts to read the database as the Database Managerwould do. This should also report  Granted/Successful  or  Denied/Failed 

based on the security options. For a non-customized new installation,

the databases APV73, NISTV73, and FACTV73 should all be accessible.

Verifying an Aspen Plus/Aspen PolymersInstallation

Note: If you have not already done so, restart Windows to activate the

changes made to your configuration during the installation.

To verify an installation of Aspen Plus on a user PC:1   On the desktop, click Start | Programs | AspenTech | Process

Modeling V7.3 | Aspen Plus | Aspen Plus User Interface.

2 For Aspen Plus:  In the  Aspen Startup  dialog box, open the existing

simulation test file,  pfdtut.bkp. The default location is:

C:\Program Files\AspenTech\Aspen Plus V7.3\GUI\XMP

For Aspen Polymers: Navigate to the test file,  polytut.bkp.

The default directory location is:

C:\Program Files\AspenTech\Aspen Plus V7.3\GUI\xmp\Polymers

3   On the menu bar, click View | Control Panel.4   On the menu bar, click Run | Run.

Simulation diagnostic messages appear in the Control Panel. The installationtest should finish with no errors or warnings.

The following message indicates a successful verification:

->Simulation calculations completed

5   On the menu bar click  Data | Results Summary | Results Status.

Page 143: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 143/214

5 Verifying and Configuring Aspen Products 143

The Results Summary  window appears, showing the run completion status.

You are now finished with the verification of the Aspen Plus or Aspen

Polymers installation.

Using the FORTRAN Compiler with Aspen

Plus

Running an Aspen Plus simulation requires a FORTRAN compiler if the model:

  Requires compiling and linking user FORTRAN subroutines

  Contains non-interpretable inline FORTRAN in the problem definition

Verifying the Installation of the FORTRANCompiler

After you install the FORTRAN compiler, you need to verify that it is operating

properly. The verification uses two example files: DRSEX14.BKP andDRUSR0.F.

To verify the installation of the FORTRAN Compiler:

1   Copy the files DRUSR0.F  and  DRSEX14.BKP,   located in the  \AspenPlus V7.3\GUI\XMP   directory, to your working directory.

2   Click  Start | Programs | AspenTech | Process Modeling V7.3 |Aspen Plus | Aspen Plus User Interface.

3   Open the file  DRSEX14.BKP   from your working directory.

4   On the Aspen Plus menu bar click View | Control Panel.

The Control Panel  window appears.

5   On the Control Panel  toolbar, click the  Run button .

6   When the  Data Regression Run Selection   screen appears, click  OK  tostart the run.

When the data regression completes, the Control Panel display should looklike this:

Page 144: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 144/214

144   5  Verifying and Configuring Aspen Products

Verifying an Aspen OLI InterfaceInstallation

Note: The Aspen OLI Interface is a subcomponent of the Aspen Plus and

Aspen Properties installations.

This section contains the instructions for verifying the installation of the AspenOLI Interface on user PCs.

Note: To use Aspen OLI, Aspen Plus must be installed prior to orsimultaneously with Aspen OLI. The OLI Engine for Aspen Plus V7.3, available

from OLI, must also be installed.

To verify the installation of Aspen OLI Interface on a user’s computer:

1   If you have not already done so, restart Windows to include changes

made to your configuration during the installation.

2   Click  Start | Programs | OLI Systems | OLI Engine in Aspen Plus

V7.3 | Chemistry Generator (or Chemistry Wizard).The Chemistry Generator  (or  Chemistry Wizard) window opens.

You can also verify your installation by checking that files were installed tothe desired installation directory.

To verify your installation this way

  Open Windows Explorer; then navigate to the destination directory:

Note: If you specified a different destination directory, you must navigate tothat location instead.

C:\Program Files\OLI Systems\OLI Engine 8.2\Aspen Plus V7.3

You should find these subdirectories:

  Chemistry Generator.

  Chemistry Wizard.

  Data Locator.

  Forms.

  OLI Engine.

  User Models.

Verifying an Aspen Distillation Synthesis

feature of Aspen Plus InstallationUse the following procedures to verify an installation of the Aspen DistillationSynthesis feature of Aspen Plus on a user PC.

Page 145: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 145/214

5 Verifying and Configuring Aspen Products 145

Verifying the Aspen Distillation SynthesisComponent

Because the Aspen Distillation Synthesis component runs under Aspen Plus,first verify the installation of Aspen Plus. For more information see “Verifyingan Aspen Plus/Aspen Polymers Installation.” 

To verify the installation of the Distillation Synthesis component:

1   On the desktop, click Start | Programs | AspenTech | Process

Modeling V7.3 | Aspen Plus | Aspen Plus User Interface.

2   In the Aspen Plus Startup  dialog box, select  Open an Existing

Simulation. Then select  More Files  and click  OK.

3   In the Open  dialog box, click the  Look in Favorites  folder icon. Thenopen  Applications,  click  3phase.bkp; then  click  Open.

4   If a message appears saying you do not have write access to this folder so

Aspen Plus is selecting a new working folder, click OK.

5   In the Connect to Engine  dialog box, select  Local PC  for the  Server

type; then click  OK.6   On the Aspen Plus menu bar, click Tools | Conceptual Design |

Ternary Maps  to start the Distillation Analysis component.

The  Ternary Maps  window appears within the Aspen Plus Window, for

example:

7   For  Comp 3  select  MCACET  from the list of components.

8   In the Explorer tree click  Ternary Plot  to start the calculations for

generating the ternary map.

When the calculations are complete the ternary map that is generated should

look like this:

Page 146: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 146/214

146   5  Verifying and Configuring Aspen Products

You have successfully verified your installation.

Aspen PlusCatCracker/Hydrocracker/

Hydrotreater/Reformer

Configuring an Aspen Plus

CatCracker/Hydrocracker/Hydrotreater/Reformer Installation

To configure the Aspen Plus CatCracker installation:

1   On the desktop, click Start | Programs | AspenTech | Process

Modeling V7.3 | Aspen Plus Based Refinery Reactors | Aspen Plus

CatCracker (or  Hydrocracker /Hydrotreater/Reformer).

The Microsoft Excel window containing the  Aspen Plus CatCracker  (or

Hydrocracker /Hydrotreater/Reformer)  worksheet tabs appears.

2   On the Excel menu bar, click Tools | Options.

The Options  window appears.

3   In the Options  window, click the  Security  tab.

4   On the Security  tab, click  Macro Security.

The Security  dialog box appears.

5   On the Security  dialog box, click the  Security Level  tab; then click

Medium.

Page 147: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 147/214

5 Verifying and Configuring Aspen Products 147

6   Click  OK  to accept the new macro security level settings and close the

Security dialog box.

7   In the Options   window, click  OK.

Configuring Microsoft SQL Server or SQL

Express

Note: Aspen Properties Enterprise Database no longer uses Microsoft SQLServer Desktop Edition (MSDE) or MS SQL Server 2000 due to problemsencountered with these SQL servers.

In order to use the Aspen Properties Enterprise Database with correspondingAspen products (Aspen Plus, HYSYS, and so on),  SQL 2005 SP3  is theminimum requirement as an install pre-requisite. Be sure to choose Mixed

Mode (in the Windows Authentication and SQL Server Authentication) duringthe "authentication mode" step of the SQL Server installation. If you are notusing mixed mode and have finished the Aspen installation, follow these steps

to ensure the mixed authentication mode is enabled.For Microsoft SQL Server:

1   Run  Start | Programs | AspenTech |Process Modeling V7.3 | Aspen

Properties | Aspen Properties Database Configuration Tester.

2   Click   Start.  An "Incorrect SQL Engine Authentication Setting" dialogappears. Follow the instructions, then click  OK  and it will correct the

authentication setting to  Mixed  Mode for you.

For SQL Server Express, the user interface for configuring the server is not

installed by default. If you do not have it, download it from Microsoft:

http://www.microsoft.com/downloads/details.aspx?FamilyId=C243A5AE-4BD1-4E3D-94B8-5A0F62BF7796&displaylang=en and install it before

performing these steps:1   Run  Start | Programs | Microsoft SQL Server 2005 | SQL Server

Management Studio Express.

2   In the  Connect to Server  window, select the server name and  Windows

Authentication. Click  Connect.

3   In the  Microsoft SQL Server Management Studio Express  windowtree on the left, right-click the name of the server and click  Properties.

4   In the Server Properties  dialog, at the left, click  Security.

5   Under  Server authentication, select  SQL Server and Windowsauthentication mode, and click  OK.

6   In the object explorer, right-click the name of the server and select

Restart. The change will take effect after that..

Verifying the Aspen Properties Enterprise

Database Installation1   On the desktop, click Start | Programs | AspenTech | Process

Modeling V7.3 | Aspen Properties | Aspen Properties DatabaseConfiguration Tester.

Page 148: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 148/214

148   5  Verifying and Configuring Aspen Products

2   When the Database Configuration Tester window appears, click  Start.

The tester will perform several tests and report the results.

  License availability: The tester verifies a license for Aspen Plus or AspenProperties is available.

  Configuration file permissions: The tester verifies that the configuration

file was installed with the correct permissions.   SQL engine authentication settings: The tester reports all servers that

have at least one Aspen Properties database that is registered on thiscomputer. On the  localhost  line, it reports the authentication mode of thelocal server and whether there is any problem with it. For other servers it

cannot check this status, so it only reports what is required.

  Database access settings: The tester attempts to access each registereddatabase and performs three tests.

o   First, it verifies that it can connect to the database at all, with either aConnection Successful  message or a message indicating the error thatoccurred.

o   Next, it attempts to read the database as Aspen Plus or Aspen

Properties would do. This should report  Granted/Successful  if thedatabase is configured for access from these programs, or

Denied/Failed  otherwise. For a non-customized new installation, the

databases APV73, NISTV73, and FACTV73 should all be accessible.

o   Finally, it attempts to read the database as the Database Managerwould do. This should also report  Granted/Successful  or  Denied/Failed 

based on the security options. For a non-customized new installation,

the databases APV73, NISTV73, and FACTV73 should all be accessible.

Aspen Plus DynamicsThis section contains the instructions for verifying the installation of AspenPlus Dynamics on user PCs.

Verifying an Aspen Plus Dynamics

Installation

To verify an installation of Aspen Plus Dynamics on a user PC

1   Create an empty test folder and copy into it the file DyEster.bkp.

The default directory location of the file is:

C:\Program Files\AspenTech\Aspen Plus Dynamics V7.3\Examples

2   On the desktop, click Start | Programs | AspenTech | Process

Modeling V7.3 | Aspen Plus| Aspen Plus User Interface.

3   Open  DyEster.bkp, located in your test folder.

Note: If you are running remotely, on the menu bar click  Run | Connect to

Engine  and make sure you are properly connected to the remote server.

4   On the menu bar, click Run | Run.

Page 149: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 149/214

5 Verifying and Configuring Aspen Products 149

5   When the run completes, on the menu bar, click File | Export.

6   Navigate to your test folder, and for the Save as Type, click  Flow Driven

Dyn Simulation.

7   Click  Save  to export the dynamic simulation.

8   On the menu bar click  Send To | Aspen Plus Dynamics Flow Driven.

Aspen Plus Dynamics starts automatically, with the  DyEster  simulation open.

9   On the menu bar, click Run | Run.

After a few moments, the dynamic simulation starts to run.

10   Make sure that the time shown in the status bar at the bottom of thewindow is advancing.

The time appears after the words  Dynamic at.

11  On the menu bar, click  File | Exit.

12  When the  This will stop the current simulation   message appears, click

OK.

13  When prompted to save changes, click  No.

Aspen Plus Dynamics closes.

You have successfully verified your installation. You can delete the test folder.

Aspen PropertiesThis section contains the following sections:

  Verifying the Aspen Properties Installation

  Configuring and Verifying an Aspen Properties Mobile Installation

  Setting Up the Aspen Properties Web Interface

  Configuring IIS for Aspen Properties Web Interface

  Configuring Excel for Performing Property Calculations

  Restricting User Access Using File Permissions

  Setting up Properties Web Interface Userfolders

  Running the Aspen Properties Web Interface

Verifying an Aspen Properties Installation

Note: If you have not already done so, restart Windows to activate thechanges made to your configuration during the installation.

To verify the installation of Aspen Properties on a user PC:

1   On the desktop, click Start | Programs | AspenTech | ProcessModeling V7.3 | Aspen Properties | Aspen Properties UserInterface.

2   In the Aspen Properties Startup  dialog box, click  Template; then clickOK.

3   Select  General  with  English Units;  then click  OK.

Page 150: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 150/214

150   5  Verifying and Configuring Aspen Products

The Components Specifications Selection  sheet appears.

4   Define these components:

o   water

o   ethanol

5   Go to the Enterprise Database  sheet and verify that the following

databanks are listed in the  Selected databanks  column:o   PURE25

o   AQUEOUS

o   SOLIDS

o   INORGANIC

6   Return to the  Components Specifications Selection  sheet, and pressF1  to display Help on Components Selection.

7   Click  Review.

The Properties Parameters Pure-Component Review-1   form appears.Parameters such as API, CHARGE, DGFORM, for the components should be

displayed.

8   Click  Next  to display the  Properties Specifications Global  sheet and

specify:

Property Method = NRTL (Top right corner field, select from the list)

9   Click  Next  to display the  Properties/Parameters/Binary

Interaction/NRTL-1/Input sheet.

Parameters should already be filled in for water and ethanol.

10  On the menu bar click  Tools | Analysis | Property | Binary.

The  Binary Analysis  dialog box appears.

11  For  Analysis  type, select  Txy.

Components water and  ethanol  are already specified for  Component 1  andComponent 2.

12  Click  Go  to perform the analysis.

When complete, the   Binary Analysis Results  dialog box and the  Txy  plotshould appear.

13  In the   Binary Analysis Results  dialog box, click on   Plot Wizard.

14  In the  Plot Wizard Step 1  dialog box, click  Next.

15  On  Step 2  of the Plot Wizard, select  KVL, then   Next  and  Finish.

The KVL plot should appear.

You have successfully verified your installation.

Configuring and Verifying an AspenProperties Mobile Installation

Configuring the Aspen Properties Mobile Server

When the server is installed, the XML file  Web.config   is created in itsinstallation folder (typically C:\Program Files\AspenTech\Aspen Properties

Page 151: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 151/214

5 Verifying and Configuring Aspen Products 151

Mobile V7.3). This file contains numerous settings established during

installation based on the locations of installed files and the version of Aspen

Properties installed on the server.

To modify the configuration:

1   Log into the server as an administrator.

2   Click  Start | Programs | Control Panel | Administrative Tools |Services  to open the  Services  window.

3   Right-click the  IIS   service and select  Stop.

4   Edit the Web.config  file as described in the next section.

5   In the Services   window, right-click the  IIS  service and select  Start.

You may edit the  Web.config  file in any text file editor (such as Notepad) orany XML editor. The  appSettings  tag and the  sessionState  tag contain the

settings which may be configured by the server administrator based on local

preferences. Within the  appSettings  tag are multiple  add tags which eachcontain a  key-value  pair as attributes.

Example settings for a typical Aspen Properties V7.3 installation<appSettings>

<add   key="apropmainPath"   value="C:\Program Files\AspenTech\Aspen Properties V7.3\Engine\xeq"/><add   key="workingDirectory"

value="C:\Documents and Settings\All Users\Application Data\AspenTech\Aspen Properties V7.3"/><add   key="database databank"   value="APV73 PURE25,APV73 AQUEOUS,APV73 SOLIDS,APV73 INORGANIC"/><add   key="ldapPath"   value="LDAP://domain.company.com "/><add   key="ldapGroupName"   value="PropUsers"/><add   key="requirePassword"   value="no"/>

</appSettings><sessionState   timeout="10"></sessionState>

Key Description

apropmainPath Path to the folder containing  apropmain.exe  for the version of 

Aspen Properties to be used. Usually this is in the  Engine\xeq

subfolder of the Aspen Properties installation.workingDirectory Path to the working directory where Aspen Properties files are

stored during runs.

database databank List of databanks searched. Each databank is written as adatabase databank  pair separated by a space, and multipledatabanks are separated by commas. This also defines thesearch order when the same parameters are available in multipledatabanks. All databases listed must be registered with AspenProperties Database Manager on the server computer.

ldapPath An LDAP URL for the domain in which users are authenticated.Typically this looks like  LDAP://domain.company.com  wheredomain  is the Windows domain containing the user accountsand  company.com  is the Internet domain for the network.

ldapGroupName The group within the above domain containing users allowed toaccess Aspen Properties Mobile.

requirePassword If set to yes, require the user to enter the password every timethey connect to the server, and do not allow it to be saved onthe iPhone. This provides security to avoid allowing a lost orstolen phone to access property data which may be confidentialinformation of your company. If set to  no, the password can be

stored in the  Settings  app as described below and does notsubsequently need to be entered.

Page 152: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 152/214

152   5  Verifying and Configuring Aspen Products

Key Description

timeout Time (in minutes) that an idle session remains open. Licensesfor idle or interrupted sessions may be retained this long pastthe last activity. Sessions which are idle for longer than this mayexperience a brief delay to re-establish the connection the nexttime they contact the server.

Configuring the Aspen Properties Mobile Client

When you start the Aspen Properties Mobile client, if the server connection

has not been configured, the  Getting started  screen will appear, providing a

brief version of the instructions in this manual. If the server connection hasbeen configured incorrectly in the client or the server is not yet running oraccessible, the  Cannot connect   message will appear.

To configure the client to connect to a server:

1   Tap Change.

2   Tap the Domain Name  field. Enter the domain name for the server.

3   Tap the User ID  field and enter the user name.

Note: You can also tap  return   to move to the next field.

4   Tap the Password  field and enter the password.

5   Tap Connect.

If the connection is unsuccessful, the  Cannot connect  message willreappear. If this happens, check the settings and network availability and tryagain.

These settings can be changed using the  Settings  app if needed:

1   Start the Settings  app.

2   Locate and tap   Aspen Properties Mobile.

3   Tap Server Connection.

4   Tap any field(s) and enter the new value(s).

5   Click the Home button to exit the  Settings  app.

Securing Aspen Properties Mobile

Aspen Properties Mobile uses Windows authentication in an LDAP domain

specified in the configuration file. The administrator should create a group for

all users who should be allowed to access Aspen Properties Mobile, andspecify the domain and group in the Web.config file as described above.

Aspen Properties Mobile server uses https on port 443. This port must be

accessible from the network(s) where users will connect with the client App in

order for Aspen Properties Mobile to work. You can test this by using thecommand  telnet   servername.domain.com   443   from this network.

It is possible for the Aspen Properties Mobile client to connect to a serverbehind a firewall using a VPN connection. You will need to have a VPN server

which provides such access and configure the connection using the standard

mechanism on the iOS device under  Settings | General | Network | VPN.

Aspen Properties Mobile uses a secure connection (https) to ensure the

security of the data when using open networks.

Page 153: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 153/214

5 Verifying and Configuring Aspen Products 153

Verifying the Aspen Properties Mobile Installation

Aspen Properties Mobile Server uses Aspen Properties installed on the same

computer as the Aspen Properties Mobile Server. It uses the sameconfiguration for Aspen Properties Enterprise Database and licensing as Aspen

Properties. You can test that these are configured properly by running AspenProperties on the Aspen Properties server.

If the configured client app can connect to the server and run a calculation,

then the installation and configuration has succeeded. If it fails, seeTroubleshooting Aspen Properties Mobile.

Setting Up the Aspen Properties Web

Interface

Aspen Properties Web Interface, a component of Aspen Properties V7.3, is aWeb-browser interface that enables users to quickly look up physical propertyinformation or to perform property calculations.

These are the system requirements for Aspen Properties Web Interface:   Microsoft Internet Information Server (IIS) must be installed. Restart your

computer after the IIS install.

  Aspen Properties V7.3 must be installed on the machine running the web

server.

Note: Only a system administrator should setup and configure AspenProperties Web Interface.

To set up Aspen Properties Web Interface for deployment

1   On your Windows XP or Vista web server machine, install Aspen Properties

V7.3, using the  Standard   install option.

For instructions see "Standard Installation."

2   Configure IIS for Aspen Properties Web Interface.

For instructions, see “Configuring IIS for the Aspen Properties Web

Interface.” 

3   Set up Properties Web Interface user folders to store problem files on the

web server.

For instructions, see “Setting Up Properties Web Interface User Folders."

Configuring IIS for the Aspen Properties

Web InterfaceAfter you install Aspen Properties on the web server, you must configure theInternet Information Server (IIS) for Properties Web Interface.

To configure IIS for Aspen Properties Web Interface:

1   On your desktop click Start | Settings | Control Panel |

Administrative Tools | Internet Information Services.

Page 154: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 154/214

154   5  Verifying and Configuring Aspen Products

2   In the console tree expand  Internet Information Server |

<your_IIS_server_name> | Web Sites.

3   Right click Default Web Site  and click  New | Virtual Directory  on themenu.

4   In the  Virtual Directory Creation Wizard,  click  Next   to continue.

5   Enter  WebProperties  as the Alias to be used to access the virtualdirectory. Then click  Next   to continue.

6   Click  Browse  and locate the WebProperties directory. For example:

D:\Program Files\AspenTech\Aspen Properties V7.3\WebProperties

7   Click  Next  to continue.

8   For the Access permissions, select:

o   Read

o   Run scripts

o   Execute

9 Click Next.

10  Click  Finish.

The WebProperties  folder appears under the  Default Web Site  in theconsole tree.

11  Set up access security for valid users of Aspen Properties Web Interface.

For instructions, see “Setting Up Directory Security ” below.

12   Provide access to Out-of-Process (OOP) COM objects.

For instructions, see "Providing Access to Out-Of-Process (OOP) COM 

Objects." 

Setting Up Directory Security

To set up access security for Aspen Properties Web Interface

1   In the console tree of the Internet Service Manager, right-click theWebProperties Default Web Site; then click  Properties  on the menu.

2   Display the Virtual Directory  tab and click the   High (isolated) option

for Application Protection  options. Then click  OK.

3   Restart the Web Server service. This can be done by right-clicking on<your_IIS_server_name> and selecting the  All Tasks | Restart IIS...

option. Pick the option   Restart Internet Services on

<your_IIS_server_name> and click  OK.

4   In the console tree of the Internet Service Manager, right-click the

WebProperties Default Web Site; then click  Properties  on the menu.5   Grant the access rights to valid users of Aspen Properties Web Interface at

your site.

For example, to display the  Windows authentication dialog box when auser wants to access Aspen Properties:

1   On the Properties  dialog box, display the  Directory Security  tab and

click the  Edit  button for   Anonymous Access and AuthenticationControl.

Page 155: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 155/214

5 Verifying and Configuring Aspen Products 155

2   In the Authentication Methods  dialog box:

o   Select the Integrated Windows authentication  check box.

o   Clear the Anonymous   access check box.

o   Clear the check boxes of the other options.

3   Click  OK, and then click  OK  again to close the dialog box.

Providing Access to Out-Of-Process (OOP)COM Objects

The IWAM_<your_IIS_server_name> accounts must include permissions to

launch and access OOP COM objects to run Web Properties successfully.

To add permission to access OOP COM objects

1   On the server machine, click  Start | Run. On the  Run dialog box enter

dcomcnfg and click  OK.

2   Open  Component Services | Computers | My Computer.

3   Right-click  My Computer   and select  Properties.

4   Display the COM Security  tab. In the  Access Permissions   section, click

Edit Default.

5   On the Access Permission  dialog box, click  Add.

6   On the  Select Users, Computers, or Groups  dialog box, click

Locations and select  <your_IIS_server_name>. Then add theseaccounts:

o   IUSR_ <your_IIS_server_name>. This is a built-in account with

guest privileges that gives anonymous access to IIS.

o   IWAM_ <your_IIS_server_name>. This is a built-in accountwith guest privileges for IIS to start out of process applications.

o   Everyone  or other <specific user names>  according to whoyou want to access the Web Server.

Note: In order to select specific user names, you may need to clickLocations again and select the appropriate domain containing those useraccounts.

7   Click  OK.

8   On the Access Permission  dialog box click  OK.

9   In the  Launch and Activation Permissions  section on the  COM

Security tab, click  Edit Default.

10  On the  Launch Permission  dialog box click  Add.

11  On the   Select Users, Computers, or Groups  dialog box, add the same

accounts from the same locations as you added to the  Access

Permission in step 6.

o   IUSR_ <your_IIS_server_name>. This is a built-in account with

guest privileges that gives anonymous access to IIS.

o   IWAM_ <your_IIS_server_name>. This is a built-in account

with guest privileges for IIS to start out of process applications.

o   Everyone  or other <specific user names>  according to whoyou want to access the Web Server.

Page 156: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 156/214

156   5  Verifying and Configuring Aspen Products

12  Click  OK.

13  On the  Launch Permission  dialog box click  OK.

14  Click  OK  to close the   My Computer Properties  dialog box.

Note: If you give access to  Everyone, make sure that  Everyone  has  Guestaccess permissions on the computer.

Restricting User Access Using File

Permissions

If the file system on the server is NTFS, then user access to the Aspen

Properties Web Interface can be controlled using file permissions. Forexample, if your Aspen Properties installation is on:

D:\Program Files\AspenTech\Aspen Properties V7.3\WebProperties

then you can restrict permission to the:

D:\Program Files\AspenTech\Aspen Properties

V7.3\WebProperties\Files

folder by right-clicking on the folder and choosing  Properties. On theSecurity tab of the dialog box, pick the users you want to have access to the

application.

Setting Up Properties Web Interface UserFolders

Users of Properties Web Interface need a place to store their problem files onthe web server. You must create the WebProperties user folder directory and

specify the location in these Properties Web Interface files:

  Userfolder.inc

  Userfolder.js

Both files are located in the  \AspenTech\Aspen Properties V7.3\WebProperties\Custom directory.

To set up the storage directory for Properties Web Interface user fileson the web server

1   Create a directory under which Properties Web Interface users can storeproblem files.

For example:  E:\WebPropsUsers

2   In this directory, create a folder for each Properties Web Interface user.

For example:  E:\WebPropsUsers\username1

3   Edit  Userfolder.inc   in the \ AspenTech\ Aspen PropertiesV7.3\WebProperties\Custom directory and specify the  UserFolder  onyour web server.

For example:

<%

Page 157: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 157/214

5 Verifying and Configuring Aspen Products 157

Dim UserFolderUserFolder = "E:\WebPropsUsers"%>

Use quotation marks to enclose the pathname.

4   Edit  Userfolder.js  in the  \AspenTech\ Aspen Properties

V7.3\WebProperties\Custom  directory and specify  top.userFolder  on

your web server.

For example:

top.userFolder = "E:\\WebPropsUsers";

Use quotation marks to enclose the pathname.

Use \\ to delimit subdirectories.

Running the Aspen Properties WebInterface

Open Internet Explorer on the server machine and use the URL:<http://localhost/webproperties>

You should be able to access the Aspen Properties Web Interface.

From any other client machine open Internet Explorer and use the URL:

<http://your_IIS_server_name/webproperties>

You should be able to access the Aspen Properties Web Interface.

Note: If you are unable to access the Web application as specified above, the

most likely reason is the lack of adequate security privileges provided to theuser in the previous steps.

Configuring Excel for Performing PropertyCalculations

Before you can use the Excel Calculator feature to perform property

calculations with Aspen Properties from within a Microsoft Excel workbook,

you must configure Excel to use an add-in.

For detailed instructions on configuring Excel, see the Aspen Properties onlinehelp under  Using Aspen Properties | Aspen Properties Excel Calculator

| Configuring the Excel Add-in.

Note: If you are upgrading from a previous version of Aspen Properties, you

must reconfigure Excel to use the new version of the add-in before Excel willuse the new version of Aspen Properties.

Page 158: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 158/214

158   5  Verifying and Configuring Aspen Products

Aspen Remote SimulationService

Configuring Aspen Remote SimulationService

The service normally uses port 8093. You may need to change it in certaincases, such as if another program on that computer uses that port, or you

need to use a particular port to connect through a firewall. To change the port

which the service uses, edit  Program Files\AspenTech\Aspen RemoteSimulation Service V7.3\server.config   in Notepad.

Locate the line

<channel ref="tcp" port="8093">

And change the number to the port you want to use, for example:

<channel ref="tcp" port="8099">

Running Aspen Remote Simulation Service

(ARSS)

Aspen Remote Simulation Service™ is a component that provides a remote

execution environment for other AspenTech tools including Aspen SimulationWorkbook and Aspen Model Deployment. ARSS allows model developers todeploy models onto a server accessible to several client computers.

AspenTech simulation software must be installed on the server, but it is not

required on the client computers. This significantly reduces the installationrequirements for the client computers.

Note that any remote software interacting with ARSS should have additional

specific information necessary for its use; for instance, Aspen SimulationWorkbook includes the Aspen Remote Simulation Service Status Monitor and

documentation on how to use it.

Tip: It is a best practice to use ARSS on the same computer as the

simulation-creating software.

Page 159: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 159/214

5 Verifying and Configuring Aspen Products 159

Aspen Solubility Modeler

Configuring an Aspen Solubility Modeler

InstallationTo configure Excel to use the Aspen Properties Add-in:

1   Start Microsoft Excel from the Start  menu. Do not open any existingspreadsheet.

2   In the Excel menu bar, click Tools  |  Add-Ins.

Note: In Excel 2007, click the Office button in the upper left corner of thewindow:

Then click  Excel Options, then  Add-Ins. In the  Manage   field at thebottom of the window, select  Excel Add-Ins  and click  Go.

The  Add-Ins  window appears. If  Aspen Properties  appears in the list of 

Add-Ins and is checked, click  Cancel  and check which version of Aspen

Properties Excel Calculator is installed by selecting  Aspen | AspenProperties | About Aspen Properties. The version number appears

below   Aspen Properties Excel Calculator  near the top of the  Aboutmessage that appears.

o   Note:  In Excel 2007, look for this command on the  Add-Ins  tab of the

ribbon. If the version of Aspen Properties Excel Calculator is equal toor newer than the version of Aspen Solubility Modeler, skip to step 7.

o   If the version of Aspen Properties Excel Calculator is older than the

version of Aspen Solubility Modeler, open  Tools | Add-Ins  again andclear the checkbox by Aspen Properties. Then close all Excel windowsand restart this procedure at step 1.

If  Aspen Properties  appears in the list of  Add-Ins  and is  not  checked,

or it does not appear in the list of  Add-Ins  at all, continue with step 3.

3   In the Add-Ins   window, click  Browse.

4   Locate  AspenProperties.xla  in the  Aspen PropertiesV7.3\Engine\xeq  folder. Click  OK. Aspen Properties should be added tothe Add-Ins list, with the box next to it checked.

Note: If a previous version of Aspen Properties had been installed in Excel

but was uninstalled, Excel will prompt you to overwrite the Add-In entry

with the new one you selected:  A file named'<path>\Engine\xeq\Aspen Properties.xla' already exists in thislocation. Do you want to replace it?

Click  Yes. The message seems to indicate Excel is replacing the .xla fileyou just selected, but actually it is just replacing the entry in the  Add-Ins

list.

5   Click  OK  to close the  Add-Ins  window. The Aspen menu should be addedto the menu bar.

Note: In Excel 2007, the menu appears on the  Add-ins  tab of the ribbon.

Page 160: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 160/214

160   5  Verifying and Configuring Aspen Products

6   Close all Excel windows, then restart Excel from the Start  menu.

7   In Excel 2007 only, click the Office button, then  Excel Options, then

Trust Center, then  Trust Center Settings. In Excel 2010 only, click  File| Options | Trust Center | Trust Center Settings. The  Trust Center

window appears.

8   In Excel 2010 only, click  Trusted Locations. If the AspenTech folder is

not already listed, click  Add new location. Browse and select theAspenTech folder (typically  C:\Program Files\AspenTech  or

C:\Program Files (x86)\AspenTech) and check   Subfolders of thislocation are also trusted. Then click  OK.

9   In Excel 2010 only, click  Add-ins. Set the options as follows:

Page 161: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 161/214

5 Verifying and Configuring Aspen Products 161

10  In Excel 2007 or 2010 only, click  ActiveX Settings  and specify the

settings as shown:

11  In Excel 2007 or 2010 only, click  Macro Settings  and specify the settingsas shown:

Page 162: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 162/214

162   5  Verifying and Configuring Aspen Products

Then click  OK  twice and then close all Excel windows and restart Excel.12  In Excel 2010 only, click  External Content  and specify the settings as

shown:

13  Then click  OK  twice and then close all Excel windows and restart Excel.

14  In the  Aspen  menu (on the  Add-ins  tab of the Ribbon in Excel 2007),

select Aspen Properties | User Options. Check the box  Suppressmessages related to invalid input. Click  OK.

15-When Excel asks whether you want to make these your default settings,click  Yes.

To launch Aspen Solubility Modeler:

1   On the desktop, click Start | Programs | AspenTech | ProcessDevelopment V7.3 | Aspen Solubility Modeler.  The  Aspen Solubility

Modeler <version> folder opens. The NRTL-SAC folder contains the

Page 163: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 163/214

5 Verifying and Configuring Aspen Products 163

Microsoft Excel and Aspen Properties files used with Aspen Solubility

Modeler.

2   Open either of the Excel files, as appropriate for your task.

The first time you start Aspen Solubility Modeler, the Security Warning

appears.

2   Click  Always trust macros from this publisher, then click  EnableMacros to enable Aspen Solubility Modeler to run and prevent thismessage from appearing in the future.

3   If this message appears:

Click  Don't Update. This message is not related to Aspen SolubilityModeler.

4   Some of the workbooks use ActiveX controls to perform special

calculations such as property analysis and phase diagrams. If this windowappears:

Page 164: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 164/214

164   5  Verifying and Configuring Aspen Products

Click  Yes to enable the ActiveX controls supplied with Aspen Solubility

Modeler.

5   If this dialog box appears:

Click  Continue.

6   When updating an existing file from a previous version, if the file is notupdating its content and this message appears, clicking  Enable Content

may help.

7   When the network or local computer is slow, it may take up to a fewminutes to check out the license or initialize ActiveX controls. During thistime, the following message may appear once or several times:

Click  OK  as many times as necessary until the Excel workbook fullyinitializes.

Aspen Utilities Planner

Aspen Utilities On-Line

OptimizerAspen Utilities On-Line Optimizer is a solution that consists of Aspen UtilitiesPlanner, Aspen Online, and CIMIO. The Aspen Utilities Planner and Aspen

Online installation, configuration, and verification are outlined in this

document. Please refer to the Aspen Manufacturing Suite DVD for CIMIOdocumentation.

Verifying an Aspen Utilities PlannerInstallation

Use the following procedure to verify an installation of Aspen Utilities on a

user PC:

Page 165: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 165/214

5 Verifying and Configuring Aspen Products 165

Note: If you have not already done so, restart Windows to activate the

changes made to your configuration during the installation.

To verify the installation of the Aspen Utilities Planner V7.3 product

on a user PC:

1   On the desktop, click Start | Programs | AspenTech | ProcessModeling V7.3 | Aspen Utilities Planner | Aspen Utilities Planner .

2   Open the Example_HTYPE.auf  file in the Aspen Utilities Planner workingfolder.

3   On the menu bar, click Run | Run.

Aspen Utilities Planner takes a few seconds to run the simulation. The

simulation should run with no errors.

To verify the Aspen Utilities Planner V7.3 Microsoft Excel Add-in:

1   Start Microsoft Excel 2003 or 2007.

2   On the menu click  Aspen Utilities | Open Aspen Utilities.

3   Navigate to the Aspen Utilities Planner working folder and openExample_HTYPE.auf .

4   On the menu bar, click Aspen Utilities | Simulate Flowsheet.

5. Click  YES on the pop up to create simulation links spreadsheet.

After a few seconds a pop up message box will indicate the completion of simulation.

6  On the menu bar, click  Aspen Utilities | Optimization | Editors.

7   A pop up box appears requesting confirmation for each of the editors. ClickYES  to create the editors.

Aspen Utilities Planner Data Editors are then displayed in Excel.

8   On the menu bar, click Aspen Utilities | Optimize Flowsheet.

The optimization should complete with no errors.

9  Close   Aspen Utilities and Microsoft Excel.

Page 166: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 166/214

Page 167: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 167/214

6 Adding and Upgrading Aspen Products 167

6 Adding and UpgradingAspen Products

This chapter describes the procedures you should follow if you are adding

Aspen Engineering products or upgrading previously installed Aspen

Engineering products.

Adding Aspen EngineeringProductsThe process of adding Aspen Engineering products is the same as installingAspen Engineering Products. The only difference is that you must click  Modifyon the  Program Maintenance  screen when it appears. On the  Feature

Selection dialog box, select the additional Aspen Engineering products you

want to install.

Upgrading Aspen EngineeringProducts

Before You Upgrade

Before you upgrade  any   existing Aspen product:

  Create forward-compatible backups of your current projects and store

them in a safe location. Binary files are not compatible across differentversions of Aspen products.

  Create backups of any customizations you wish to retain and store themin a safe location.

Note: When you remove the old version of the Aspen product, the product

folder and all of its contents will be deleted.

Page 168: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 168/214

168   6  Adding and Upgrading Aspen Products

Aspen OnLine Users

To back up your projects for Aspen OnLine:

1   Launch Aspen OnLine.

2   Click  File | Export.

The Export Project Configuration Information  window appears.

3   On the Project  tab, set the Destination Directory to the directory whereyou want your old project files to be stored.

4   Click   Export.

If you have any Beta products installed, uninstall them  before   installing the

new versions of those products.

Occasionally, a manual change is made to an application file to fix a specific

problem. Such a change is referred to as a “hot fix.” If a “hot fix” has been

made to any currently installed Aspen application, you  must   uninstall theapplication before installing any service pack or upgrade.

Product Upgrade Task Summary

The following table summarizes the tasks you should perform to prepare for

an Aspen software upgrade. An asterisk (*) indicates the recommendationthat you keep the previous version on your machine (if there is sufficient diskspace) until you are satisfied with the installation of the new version.

Before you upgrade do this

Aspen Adsorption* Create language (.ada) file versions for forwardcompatibility and store them in a safe location.

Aspen Batch Distillation Create language (.bspf) file versions for forwardcompatibility and store them in a safe location.

Aspen Batch ProcessDeveloper*

Create a backup of project files and store them in asafe location. After you install the latest version, updatethe existing project files. For instructions, see “Updating

 Aspen Batch Process Developer Project Files."

Aspen Chromatography* Create language (.cra) file versions for forwardcompatibility and store them in a safe location.

Aspen Custom Modeler* Create language (.acmf ) file versions for forward

compatibility and store them in a safe location.

Aspen Exchanger Designand Rating

Save copies of customized cost files to a safe location.

Aspen OnLine Remove the older version of Aspen OnLine  before  youinstall the new version.

Aspen Plus Create backup (.bkp  and .apmbd) versions of files fromAspen Plus 12.1 or earlier for forward compatibility andstore them in a safe location. Newer Aspen Plus filescontain an embedded backup file which will be read bylater versions.

Aspen Plus Dynamics* Create language (.dynf) file versions for forwardcompatibility and store them in a safe location.

Aspen Properties Create backup (.aprbkp) versions of files from Aspen

Properties 12.1 or earlier for forward compatibility and

Page 169: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 169/214

6 Adding and Upgrading Aspen Products 169

store them in a safe location. Newer Aspen Propertiesfiles contain an embedded backup file which will be readby later versions.

Upgrading Aspen Products

To upgrade any Aspen product

1   If desired or necessary (due to disk space or compatibility limitations),remove old versions of Aspen products.

2   Install the upgraded Aspen product. See "Installing Aspen Products" for

specific details.

Repairing or Modifying Products

For information on repairing or modifying Aspen products, see "Installing Aspen Products," for more details.

After You Upgrade

When the installation process is complete, the following Aspen productsrequire additional configuration:

I f you upgraded See

Aspen Batch ProcessDeveloper

See “Updating Aspen Batch Process Developer Project Files” below.

Aspen Plus See "Re-registering CAPE-OPEN Property Packages" below.

Aspen Properties See "Re-registering CAPE-OPEN Property Packages" below.

Start the new version of the installed Aspen product and open the saved files

to make sure they work properly in the new version. For instructions, see theappropriate Aspen product chapter.

After you are satisfied that the new version of the Aspen product is working

correctly, uninstall the old version, if necessary.

Updating Aspen Batch Process DeveloperProject Files

Aspen Batch Process Developer automatically updates previously createdprojects to a format compatible with new versions.

To convert existing projects to a format compatible with the newversion of Aspen Batch Process Developer:

1   After you install the new version of Aspen Batch Process Developer, startAspen Batch Process Developer.

2   Open an existing project.

A message box should appear indicating that the project is being converted tothe new version.

The conversion process may take some time. Please be patient.

Page 170: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 170/214

170   6  Adding and Upgrading Aspen Products

3   When the conversion is complete, verify that your projects have been

successfully converted and that your simulation results are accurate.

4   Now you can uninstall the previous version of Aspen Batch ProcessDeveloper and remove your project backup files.

Re-registering CAPE-OPEN PropertyPackages

You may need to re-register CAPE-OPEN property packages created withversions of Aspen Plus or Aspen Properties that you have uninstalled, if they

are unavailable when you use the new Aspen Plus or Aspen Properties CAPE-

OPEN Thermo System to import a CAPE-OPEN property package. To re-register a CAPE-OPEN property package, locate its .cota  file and double-click

it.

Page 171: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 171/214

7 Repairing Aspen Products 171

7 Repairing Aspen Products

Use the instructions in this section to repair corrupt data or missing elementsin your AspenTech applications, databases, and INI files.

Note: If you are upgrading to a new version of a product, see " Chapter 6:

 Adding and Upgrading Aspen Products” for instructions.

Repairing Products andSubfeatures

To repair products and subfeatures

1   Log on to the computer, using an account with Local Administratorprivileges.

2   Insert the Aspen Engineering  DVD (DVD 1) into the DVD drive.

Note: If the installation does not start automatically, click  Start | Run. In

the  Run dialog box, enter  <drive>:\setup (where  <drive>   is the drive

letter assigned to your DVD drive); then click  OK.

Page 172: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 172/214

172   7  Repairing Aspen Products

The  AspenTech DVD Browser  window appears.

Note: If you want to see only products that you are licensed to install, select

the   Show Licensed Products Only  check box.

3   Click the Products  tab.

A license requirement dialog box appears.

4   Click  OK.

Page 173: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 173/214

Page 174: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 174/214

174   7  Repairing Aspen Products

The  License Files   dialog box appears..

7   Do the following:

o   If you have one or more standalone license files that are local to yourcomputer, click  Add License File, and then use the  Open  dialog box

to locate the license files (*.lic,  *.slf ). Then click  Next.

-and/or-

o   If you have licenses that are obtained from a network license server,

click  Next.

The License Servers  dialog box appears.

8   In the License Servers  dialog box, enter the  License Server  name and

click  Add Server, and repeat until all applicable  License Server  namesare included in the list. Then click  Next.

Page 175: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 175/214

7 Repairing Aspen Products 175

The Determining Product Licenses   dialog box appears.

9   After the Licenses  list is populated with all licenses found, click  Next.

10  Click   Products | Aspen Engineering; then  click  Install.

The Windows Installer  view appears briefly as it prepares for installation.One of the following  AspenTech Installer  dialogs appears.

The AspenTech  Upgrade  Wizard appears.

11  Click  Next  to continue.

Page 176: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 176/214

176   7  Repairing Aspen Products

The AspenTech  Program Maintenance   dialog box appears.

12  Click  Next, accepting the  Upgrade or Repair   (default) option

The Computer Configuration Type  dialog box appears.

13  Click  Standard Install  to uninstall the Aspen software on a singlecomputer or   Server Install  to uninstall Aspen software on a server.

14  Click  Next.

The Ready to Upgrade or Repair the Program  dialog box appears.

Page 177: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 177/214

7 Repairing Aspen Products 177

15  To complete the repair or upgrade, click  Install.

16  Wait as the installation begins.

Setup Complete

Once the installation is finished, the  Wizard Completed  dialog box appears.

17  Click  Finish.

Page 178: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 178/214

178   7  Repairing Aspen Products

18  A message box may appear asking you to restart your computer. Do

either of the following:

o   Click  Yes to restart your computer right away.  The systemshuts down and reboots.

o   Click  No to restart it later.

19  When the system reboot is complete, log on to Windows using an accountwith local Administrator privileges.

Note: At any time before the repairs are finished, to stop the repair processand exit the installation, click  Cancel.

Page 179: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 179/214

8 Removing Aspen Products 179

8 Removing Aspen Products

Before You Remove Any AspenProductIf you are removing products in preparation for an upgrade, save files andcustomizations in portable formats and in safe locations. For more

information, see Chapter 6, “ Adding and Upgrading Aspen Products.” 

OverviewUse the instructions in this section to remove Aspen products and theirsubfeatures from your system using AspenTech DVDs.

There are three methods for initiating the removal or uninstallation of 

AspenTech software as described below.

Removing Aspen Products

Select one of the following options to remove AspenTech products.

Using the Microsoft Add/Remove Utility1   On the Microsoft taskbar, click Start | Settings  |  Control Panel  |  Add

or Remove Programs.

The Add/Remove Programs dialog box appears with a list of all programsavailable for removal on the computer.

2   Select the AspenTech product to remove, such as Aspen Plus; then click

Remove.

3   Click  Yes to confirm removal of the feature.

The Windows Installer  begins the removal.

4   When the removal is complete, on the  Add/Remove Programs  dialog

box, click  Close

Page 180: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 180/214

180   8  Removing Aspen Products

Using the Microsoft Taskbar1   On the Microsoft taskbar, click Start | Programs | AspenTech |

Uninstall AspenTech Software.

The  AspenTech Uninstaller – Select Products  dialog box appears.

2   Click the products that you want to uninstall.

orClick   Select All  to remove all products listed.

3   Click  Uninstall.

Removal of the selected products begins.

4   When the uninstallation is complete, on the   AspenTech Uninstaller –Uninstall Progress  dialog box, click  Close.

Using the aspenONE  Removal Program

To remove products and subfeatures

1   Log on to the computer, using an account with Local Administratorprivileges.

2   Insert the Aspen Engineering  DVD (DVD 1) into the DVD drive.

Note: If the installation does not start automatically, click  Start | Run. In

the  Run dialog box, enter  <drive>:\setup (where  <drive>   is the drive

letter assigned to your DVD drive); then click  OK.

The  AspenTech DVD Browser  window appears.

3   Click the Products  tab.

Note: If you want to see only products that you are licensed to install, selectthe   Show Licensed Products Only  check box.

Page 181: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 181/214

8 Removing Aspen Products 181

A license requirement dialog box appears.

4   Click  OK.

The License Configuration  Wizard appears.

5   Click  Next.

The License Configuration Type   dialog box appears.

Page 182: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 182/214

182   8  Removing Aspen Products

6   Accept the default  Both  option and click  Next.

The  License Files   dialog box appears..

7   Do the following:

o   If you have one or more standalone license files that are local to your

computer, click  Add License File, and then use the  Open  dialog boxto locate the license files (*.lic,  *.slf ). Then click  Next.

-and/or-

o   If you have licenses that are obtained from a network license server,click  Next.

The License Servers  dialog box appears.

8   In the License Servers  dialog box, enter the  License Server  name andclick  Add Server, and repeat until all applicable  License Server  names

are included in the list. Then click  Next.

The Determining Product Licenses   dialog box appears.

Page 183: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 183/214

8 Removing Aspen Products 183

9   After the Licenses  list is populated with all licenses found, click  Next.10  Click   Products | Aspen Engineering; then  click  Install.

The Windows Installer  view appears briefly as it prepares for installation.One of the following  AspenTech Installer  dialogs appears.

The AspenTech  Upgrade  Wizard appears.

11  Click  Next  to continue.

The AspenTech  Program Maintenance   dialog box appears.

12  On the AspenTech  Program Maintenance  dialog box, click  Remove All.

Page 184: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 184/214

184   8  Removing Aspen Products

13  Click  Next.

The  Remove the Program  dialog box appears.

14  Click  Remove.

Page 185: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 185/214

8 Removing Aspen Products 185

Progress screens display showing the progress of removing the Aspen

products.

When the removal is complete, the  Uninstall Complete  dialog box appears.

15  Click  Finish.

16  A message box appears asking you to restart your computer. Do either of 

the following:

o   Click  Yes to restart your computer right away.  The systemshuts down and reboots.

o   Click  No to restart it later.

17  When the system reboot is complete, log on to Windows using an account

with local Administrator privileges.

After You Remove Aspen

ProductsGo to the AspenTech or Aspen product directory on the machine to verify that

the files have been removed. If necessary, delete any remaining foldersmanually.

Page 186: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 186/214

186   8  Removing Aspen Products

Using Excel After Uninstalling Aspen BasicEngineering

If you attempt to use Excel after uninstalling Aspen Basic Engineering, youmay encounter an error. The error may report that it cannot find Aspen Basic

Engineering.

If this problem occurs, do the following:

1   Start the MS Excel application.

2   Click  Tools | Add-In.

3   Clear the Aspen Basic Engineering  option.

Note: You must do this for each network user PC when Aspen Basic

Engineering is uninstalled.

Page 187: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 187/214

9 Troubleshooting 187

9 Troubleshooting

This chapter contains:

  Information that may help you if you have problems installing AspenEngineering products.

  Some typical error messages.

Common ProblemsThe following information may be useful to you if you encountered problems

during installation.

Checking Installation Account Privileges

This section contains information about installation account privileges.

  You must be logged on as a   local administrator  to install software on

the PC.

Other Troubleshooting Tips

If your installation does not appear to work correctly:

  Ensure you have completed installation of all the required components.

  Ensure you have restarted your server and/or user PC(s).

  If you are installing on a server, remember that whenever you map fromthe user PC to the server, use the same drive letter.

  If you are performing a server installation, you must have appropriate

network access between server and client machines in both directions.

Page 188: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 188/214

188   9  Troubleshooting

Error Messages

License ErrorsProblem You try to run an Aspen application, and the following message appears:

LICENSE VALIDATION/CHECKOUT FAILURE FOR <Aspen Product>

Cause The licensing for the Aspen product has not been properly installed.

Solutions Reinstall the license. For instructions, see Software License Manager (SLM) Installation and Reference Guide.

Client-Server Installations

This section lists error messages that you may encounter when installing the

Aspen products in a client-server configuration.

The following error messages may appear if a server verification fails.

Message Failed to connect to remote host via rexec. Probable cause badpassword, bad hostname, or network not installed.

Cause Either the remote or the local host cannot resolve the remote or localhost name into an address. Each operating system and network protocolresolves names differently.

Solution Check to make sure that you have a valid DNS or WINS server on thenetwork and that the client is properly configured to access it.

Troubleshooting Installation of 

Aspen Products

.NET Framework ErrorProblem When installing Aspen products, you get an error message about .NET

Framework versions..

Cause Your machine has no version of .NET installed. The AspenTech installerinstalls .NET Versions 1.1, 2.0, 3.0 and 3.5. When the installer attemptsto install .NET Version 3.0, it displays an error.

Solution Cancel the AspenTech installation, reboot your machine, and restart themachine. Then continue with the AspenTech installation.

Installation Stalls When Installing AspenSimulation Workbook or Aspen UtilitiesPlannerProblem When installing Aspen Simulation Workbook or Aspen Utilities Planner,

the AspenTech installer gets into an infinite loop early in the installation(while installing required components before the actual product

Page 189: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 189/214

9 Troubleshooting 189

installation begins).

Cause When Aspen Simulation Workbook or Aspen Utilities Planner is installed

on MS Office 2003, the patch for Microsoft KB 907417 is required beforeour product can be installed. This patch can fail in some cases whenthere is a problem with the Office installation, and when it does so it cansend the AspenTech installer into an infinite loop.

Solution Visit http://support.microsoft.com/kb/907417 to download and installthe patch manually. Any errors that occur during the installation will bevisible. The patch may request the original Office installation media torestore damaged or missing files. If the patch still fails, consult Microsoftsupport.

Troubleshooting SQL ServerProblems

Microsoft SQL Server Setup msxml6r.dll WarningWhen installing MS SQL Server 2005 or 2008 (including the Express edition)

on non-English versions of Windows XP SP3, you may get a notice saying thatthe installer cannot update msxml6r.dll because the file is protected.

This is a conflict between Windows XP SP3 and SQL Server. SQL Server tries

to install the English version of a DLL which is included in localized versionwith Windows XP SP3. The localized version works with SQL Server, so this is

not generally a problem.

If this message appears, click  OK  (or local equivalent). Microsoft has moreinformation about this problem at http://support.microsoft.com/kb/958897.

Configuring the SQL Server for SQL Server andWindows Authentication

If SQL Server or SQL Express is required, it must be configured to use  SQL

Server and Windows authentication mode.

Configuring Microsoft SQL Server or SQL Express

Note: Aspen Properties Enterprise Database no longer uses Microsoft SQL

Server Desktop Edition (MSDE) or MS SQL Server 2000 due to problemsencountered with these SQL servers.

In order to use the Aspen Properties Enterprise Database with corresponding

Aspen products (Aspen Plus, HYSYS, and so on),  SQL 2005 SP3  is the

Page 190: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 190/214

190   9  Troubleshooting

minimum requirement as an install pre-requisite. Be sure to choose Mixed

Mode (in the Windows Authentication and SQL Server Authentication) during

the "authentication mode" step of the SQL Server installation. If you are notusing mixed mode and have finished the Aspen installation, follow these stepsto ensure the mixed authentication mode is enabled.

For Microsoft SQL Server:

1   Run  Start | Programs | AspenTech |Process Modeling V7.3 | Aspen

Properties | Aspen Properties Database Configuration Tester.

2   Click   Start.  An "Incorrect SQL Engine Authentication Setting" dialogappears. Follow the instructions, then click  OK  and it will correct the

authentication setting to  Mixed  Mode for you.

For SQL Server Express, the user interface for configuring the server is notinstalled by default. If you do not have it, download it from Microsoft:

http://www.microsoft.com/downloads/details.aspx?FamilyId=C243A5AE-4BD1-4E3D-94B8-5A0F62BF7796&displaylang=en and install it beforeperforming these steps:

1   Run  Start | Programs | Microsoft SQL Server 2005 | SQL Server

Management Studio Express.2   In the  Connect to Server  window, select the server name and  Windows

Authentication. Click  Connect.

3   In the  Microsoft SQL Server Management Studio Express  windowtree on the left, right-click the name of the server and click  Properties.

4   In the Server Properties  dialog, at the left, click  Security.

5   Under  Server authentication, select  SQL Server and Windows

authentication mode, and click  OK.

6   In the object explorer, right-click the name of the server and selectRestart. The change will take effect after that.

Verifying the Aspen Properties EnterpriseDatabase Installation1   On the desktop, click Start | Programs | AspenTech | Process

Modeling V7.3 | Aspen Properties | Aspen Properties DatabaseConfiguration Tester.

2   When the Database Configuration Tester window appears, click  Start.

The tester will perform several tests and report the results.

  License availability: The tester verifies a license for Aspen Plus or Aspen

Properties is available.

  Configuration file permissions: The tester verifies that the configuration

file was installed with the correct permissions.

  SQL engine authentication settings: The tester reports all servers thathave at least one Aspen Properties database that is registered on this

computer. On the  localhost  line, it reports the authentication mode of thelocal server and whether there is any problem with it. For other servers it

cannot check this status, so it only reports what is required.

  Database access settings: The tester attempts to access each registered

database and performs three tests.

Page 191: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 191/214

9 Troubleshooting 191

o   First, it verifies that it can connect to the database at all, with either a

Connection Successful  message or a message indicating the error that

occurred.

o   Next, it attempts to read the database as Aspen Plus or Aspen

Properties would do. This should report  Granted/Successful  if thedatabase is configured for access from these programs, or

Denied/Failed  otherwise. For a non-customized new installation, thedatabases APV73, NISTV73, and FACTV73 should all be accessible.

o   Finally, it attempts to read the database as the Database Managerwould do. This should also report  Granted/Successful  or  Denied/Failed 

based on the security options. For a non-customized new installation,

the databases APV73, NISTV73, and FACTV73 should all be accessible.

Troubleshooting IndividualAspen Products

Troubleshooting Aspen Adsorption, AspenChromatography, Aspen Custom Modeler,

and Aspen Plus DynamicsMessage The name specified is not recognized as an internal or external

command, operable program, or batch file.

Cause The  sim_server.exe  program is not at the location you specified.

Solution Repeat the verification, specifying the correct location for thesim_server.exe  program.

Message The dynamic link library  filename.dll  could not be found in the specifiedpath.

Cause A DLL required to run the  sim_server.exe  program is missing from

your system. This is probably caused by a failure during installation.

Solution Note the name of the DLL and then use the  Search  tool to search yoursystem for the missing DLL.

Message Process  simserver  failed to start. If you want to see more detail, clickthe  Details  button.

Cause The User Rights Policy that allows the user to log on as a batch job hasnot been granted to the user shown in the error message.

Solution See "Configuring a Windows Server as an Aspen Host."

You might see these error messages on a user PC that is unable to connect to

a server:

Message CreateProcessAsUser: The system cannot find the file specified.(2)

Cause The program specified does not exist.

Solution Check that the server code is installed at the location specified, for

Page 192: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 192/214

192   9  Troubleshooting

example, C:\Program Files\AspenTech\AMSystemV7.3\bin\

sim_server.exe.

Troubleshooting Aspen Basic Engineering

Using Applications Immediately after anInstallation

If you attempt to open Aspen Basic Engineering applications immediatelyafter installation, and have not yet shut down your PC/server, the followingerror message may appear:

If these messages appear:

1   Exit all Aspen Basic Engineering applications and log out of windows.

2   Log back into Windows.

3   Open your Aspen Basic Engineering applications.

Restarting the Aspen Basic Engineering BrokerService Manually

If you get the following error message during the install, you will be able tostart the broker manually once the installation has completed.

The most common cause of this message is an invalid password entered intothe   Aspen Basic Engineering Broker  dialog during the install.

To start the broker service:

1   Ensure the user account password is valid and meets your company’scurrent network password policy:

Page 193: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 193/214

9 Troubleshooting 193

o   Checking the user account password

With the username and password given during the  Aspen

Basic Engineering Broker  dialog try logging into the localmachine with these settings. If the user account fails to log in,

it is likely that the password you have does not met yournetwork password policy. If the account is not on the Local

Machine contact your network administrator for assistance. If itis a   Local User  account follow the   Changing the user

account password procedure below.

o   Changing the user account password

A  Right click My Computer  and select  Manage, or go to  Start| Settings | Control Panel | Administrative Tools |Computer Management.

B  In the left pane, click  Local Users and Groups  followed bythe  Users  option.

C  Right-click the user used to run the Zyqad broker; then click

Set Password. Enter and confirm a new password. If you have

problems with this, contact your network administrator forassistance.

2   Ensure the user is a member of the Zyqad Administrator  group:

Checking the user account is a Zyqad Administratoraccount

o   Right click My Computer | Manage, or go to   Start | Settings| Control Panel | Administrative Tools | Computer

Management.

o   In the left pane, click Local Users and Groups; then click

Groups.

o   Right-click  ZyqadAdministrators; then select  Add to Groupor click  ZyqadAdministrators; then go to Action | Add to

Group.

o   In the list of members, see if the user you want to run theZyqad Broker is listed. If the user is not, click  Add. In  Lookin:, click the domain the user is in: if it is a  Local User  account

this will be the computer name. On the list, click the user; then

and click Add or, alternatively in the bottom textbox, type theDOMAIN\USERACCOUNT; then click  Check Names.

3   Restart the Aspen Basic Engineering Broker Service:

Restarting the Aspen Basic Engineering Broker Service

o   Navigate to the DataServices\Bin  directory.

o   Copy the following into the command prompt and press Enter

(replace where necessary):

AZ131Broker.exe/regServerAZ131Broker.exe /Install /Service /AdminGroupZyqadAdministrators /RunAs [AZ_USER] /Password[AZ_UserPass] /WorkspacesFolder [PathtoWorkspaces]/LibrariesFolder [pathtolibfolder] /ExampleWorkspace[AZ131]

Page 194: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 194/214

194   9  Troubleshooting

where:

[AZ_USER] = The user you just added to the ZyqadAdministrators (if 

not a Local User account include the domain for example,domain1\user).

[AZ_UserPass] = The password given to that user account.

[PathtoWorkspaces] = The full path in "s to the workspaces folder.

[pathtolibfolder] = The full path in "s to the  WorkspaceLibrariesfolder.

[AZ131] = Whatever you want to call the example workspace, (Note: /ExampleWorkspace [AZ131] you do not have to give this if you do not

want an example workspace).

4   Checking the Aspen Basic Engineering Broker Service has started:

Checking the service has started

o   Right-click  My Computer | Manage, or go to  Start | Settings

| Control Panel | Administrative Tools | Computer

Management.o   In the left pane, expand Services and Applications; then click

Services.

o   In the right pane look at the services to see if the serviceAZ131Broker has started

Troubleshooting Aspen Batch ProcessDeveloper

Aspen Batch Process Developer has the following special troubleshootingprocedures.

Problem You cannot generate Excel reports.

Cause This can occur when certain system files shared by Aspen Batch ProcessDeveloper and Excel are not properly registered.

Solution You can avoid this problem by following the installation instructions forExcel before   installing Aspen Batch Process Developer. Unfortunately, if you already have this problem, you must start over:

1   Uninstall Aspen Batch Process Developer by following the instructionsin “Chapter 8: Removing Aspen Products.” 

2   Uninstall Microsoft Office.

3   From Windows Explorer or File Manager, manually delete the files inC:\Program Files\Common Files\Microsoft Shared\Dao.

These are the system files that are not properly registered.

4   Reinstall Microsoft Office, ensuring that the  Data Access  option forExcel is selected.

5   Reinstall Aspen Batch Process Developer

Problem You cannot generate Visio diagrams.

Cause This can occur if the PC has not rebooted after Aspen Batch ProcessDeveloper or Visio installation, or if Visio cannot locate the  Add-ons

Page 195: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 195/214

9 Troubleshooting 195

path when Visio is launched.

Solution You can avoid the first problem by rebooting your PC after installation.

If Visio cannot locate the  Add-ons  path when it is launched, check thecheck box in the  Launch Visio  dialog box that appears when you launchthe equipment diagram from Aspen Batch Process Developer. This resetsthe Visio   Add-ons  path and restarts Visio, which should then generate

the diagram correctly.

Troubleshooting Aspen EconomicEvaluation (Aspen Process Economic

Analyzer, Aspen Capital Cost Estimator,Aspen In-Plant Cost Estimator)

Description

Users running Microsoft Windows with Windows Installer 3.1 may experience

coexistence issues with Economic Evaluation V7.2 and previous versions as

described below:1. The following aspenONE applications are installed on a machine:

a. EEV7.2.1 (or EEV7.2), EEV7.3

b.   HYSYS   and/or Aspen Plus V7.2+EPs

2. Invoking the Export to EE  feature in either  HYSYS  or Aspen Plus

invokes EEV7.2.1 (or EEV7.2) instead of EEV7.3. This may occur if none of the EE installed software versions are run after installation.

This is due to the windows installer resiliency behavior. Once the

problem occurs in one user environment, it is observed with all otherusers on that machine.

Workaround:

1. Update Windows Installer to version 4.5, which can be downloaded fromthe following site.

a.  http://www.microsoft.com/downloads/details.aspx?FamilyID=5a58

b56f-60b6-4412-95b9-54d056d6f9f4&displaylang=en

Note: See the installation guide on how to check which version of Windows Installer is present on your system.

2. Ensure EE V7.2.1 (or EEV7.2)/V7.3 is executed as standalone application

before invoking EE via  HYSYS  V7.2 (or Aspen Plus V7.2).

3. In cases where the problem occurs, an upgrade/repair installation of EE

V7.3 can be performed by running the EE V7.3 installation again. The

procedure allows the EE V7.3 to be reset as the default costing feature w/

HYSYS  /Aspen Plus V7.2.

Comment:   Following the steps below on the system where EE V7.3 is

installed alongside previous versions of EE can avoid the aforementioned

issues.

1. Update the Windows Installer to version 4.5

Page 196: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 196/214

196   9  Troubleshooting

2. Launch EE V7.2.1 (or EEV7.2) and allow the EE V7.2.1 Windows

Installer resiliency to go through, if this the first time EE V7.2.1 is

being launched under this user account.

3.   After closing EE V7.2.1, Launch EE V7.3 and allow the EE V7.3

Windows Installer resiliency to go through, if this the first time EE V7.3

is being launched under this user account.

Troubleshooting Aspen Online Deployment

Aspen Online Deployment has the following special troubleshootingprocedures.

Problem An online application reports that the solver failed.

Cause This can occur for a variety of reasons, from a failure to converge on asolution to a network communication failure.

Solution In order to solve the problem, you should first examine the localapplication log. This log is found in the  \Documents and Settings\AllUsers\Application

Data\AspenTech\RTE\V7.3\Clouds\Online\sys  directory. The logis named with the application name and has the extension  .log  (forexample, the application   HEATXN1  would have a log   HEATXN1-solver.log); there is also a backup log file that contains older logmessages (for example,  HEATXN1-solver_backup.log).

You can get more detailed information, including all the solver messages,

by turning on diagnostic logging for an application. Turn on diagnosticlogging by using the APC Web Server to set the   DebugPrint  entry toFileOutput. You get access to the DebugPrint  entry by clicking on theapplication name in one of the online views in PCWS. The diagnostic logfiles are in the same location as the application logs, but have a nameending with “-diag.log” instead of “-solver.log”.

Note:  To avoid causing further problems with the software, make a copyof the log and examine the copy.

Examine the log file to see if there is a solver problem (for example,failure to converge) or a system problem (for example, an exception anda software procedure call stack trace).

If the failure was due to a solver problem, and the application wasconfigured to save a snapshot when the solver fails, then you can usethe Aspen Online Deployment Desktop to retrieve the application

snapshot matching the failed solution; you can extract the case file fromthat snapshot, load it into the simulator desktop, and determine thereason that a solution could not be calculated.

If the failure was due to a system problem, and the cause of the problemis not clear from the error messages in the log, then contact AspenTech

Support for assistance.

Page 197: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 197/214

9 Troubleshooting 197

Troubleshooting Aspen Plus

Microsoft SQL Server Setup msxml6r.dll Warning

When installing MS SQL Server 2005 or 2008 (including the Express edition)

on non-English versions of Windows XP SP3, you may get a notice saying thatthe installer cannot update msxml6r.dll because the file is protected.

This is a conflict between Windows XP SP3 and SQL Server. SQL Server triesto install the English version of a DLL which is included in localized version

with Windows XP SP3. The localized version works with SQL Server, so this is

not generally a problem.

If this message appears, click  OK  (or local equivalent). Microsoft has more

information about this problem at http://support.microsoft.com/kb/958897.

Configuring the SQL Server for SQL Server andWindows Authentication

If SQL Server or SQL Express is already installed before installing AspenTechproducts, it must be configured to use  SQL Server and Windows

authentication mode.

Configuring Microsoft SQL Server or SQLExpress

Note: Aspen Properties Enterprise Database no longer uses Microsoft SQL

Server Desktop Edition (MSDE) or MS SQL Server 2000 due to problems

encountered with these SQL servers.

In order to use the Aspen Properties Enterprise Database with corresponding

Aspen products (Aspen Plus, HYSYS, and so on),  SQL 2005 SP3  is theminimum requirement as an install pre-requisite. Be sure to choose Mixed

Mode (in the Windows Authentication and SQL Server Authentication) during

the "authentication mode" step of the SQL Server installation. If you are notusing mixed mode and have finished the Aspen installation, follow these steps

to ensure the mixed authentication mode is enabled.

For Microsoft SQL Server:

1   Run  Start | Programs | AspenTech |Process Modeling V7.3 | AspenProperties | Aspen Properties Database Configuration Tester.

2   Click   Start.  An "Incorrect SQL Engine Authentication Setting" dialogappears. Follow the instructions, then click  OK  and it will correct theauthentication setting to  Mixed  Mode for you.

Page 198: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 198/214

198   9  Troubleshooting

For SQL Server Express, the user interface for configuring the server is not

installed by default. If you do not have it, download it from Microsoft:

http://www.microsoft.com/downloads/details.aspx?FamilyId=C243A5AE-4BD1-4E3D-94B8-5A0F62BF7796&displaylang=en and install it beforeperforming these steps:

1   Run  Start | Programs | Microsoft SQL Server 2005 | SQL Server

Management Studio Express.

2   In the  Connect to Server  window, select the server name and  Windows

Authentication. Click  Connect.

3   In the  Microsoft SQL Server Management Studio Express  window

tree on the left, right-click the name of the server and click  Properties.

4   In the Server Properties  dialog, at the left, click  Security.

5   Under  Server authentication, select  SQL Server and Windows

authentication mode, and click  OK.

6   In the object explorer, right-click the name of the server and selectRestart. The change will take effect after that.

Verifying the Aspen Properties EnterpriseDatabase Installation1   On the desktop, click Start | Programs | AspenTech | Process

Modeling V7.3 | Aspen Properties | Aspen Properties DatabaseConfiguration Tester.

2   When the  Database Configuration Tester   window appears, click  Start.

The tester will perform several tests and report the results.

  License availability: The tester verifies a license for Aspen Plus or AspenProperties is available.

  Configuration file permissions: The tester verifies that the configuration

file was installed with the correct permissions.

  SQL engine authentication settings: The tester reports all servers thathave at least one Aspen Properties database that is registered on this

computer. On the  localhost  line, it reports the authentication mode of the

local server and whether there is any problem with it. For other servers itcannot check this status, so it only reports what is required.

  Database access settings: The tester attempts to access each registered

database and performs three tests.

o   First, it verifies that it can connect to the database at all, with either aConnection Successful  message or a message indicating the error that

occurred.

o   Next, it attempts to read the database as Aspen Plus or AspenProperties would do. This should report  Granted/Successful  if the

database is configured for access from these programs, or

Denied/Failed  otherwise. For a non-customized new installation, thedatabases APV73, NISTV73, and FACTV73 should all be accessible.

o   Finally, it attempts to read the database as the Database Managerwould do. This should also report  Granted/Successful  or  Denied/Failed 

based on the security options. For a non-customized new installation,the databases APV73, NISTV73, and FACTV73 should all be accessible.

Page 199: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 199/214

9 Troubleshooting 199

Interface

You may encounter error messages when starting the Aspen Plus User

Interface or when attempting to run a simulation:

Message When starting the Aspen Plus User Interface this message appears:

Aspen Plus Version <version> could not open the Data Browser menu

database. Data entry and results forms will not be available.Cause The installation did not correctly build the Data Browser and   Forms

database file,   ApwnMenu.  This file, located by default in

C:\Program Files \AspenTech\Aspen Plus V7.3, should always be

larger than 1 MB.

Solution   1   In a  Command Prompt (DOS) window, run theAPFormSetup.exe utility. The default location is:C:\Program Files\AspenTech\Aspen Plus V7.3\GUI\XEQ.

2   On the Register Forms  dialog box, accept all defaults; then clickNext.

3   On the Register PlotWizard  dialog box, accept all defaults; thenclick  Finish.

Troubleshooting Aspen Properties Mobile

Case 1: App Cannot Connect to Server

Problem

App shows  Cannot connect  message.

Cause 1

Server domain name, username, and/or password are misspelled or wrong.

Solution 1

Fix these in the app's settings. See   Configuring the Aspen PropertiesMobile Client  in Chapter 2.

Cause 2

Server computer is offline or IIS is not running.

Solution 2

Fix these problems on the server.

Cause 3

Server network is unreachable.

Solution 3

Move to a location where Wi-fi or 3G phone service is available.

Page 200: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 200/214

Page 201: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 201/214

9 Troubleshooting 201

Solution 8

Ensure that the user  IUSR_ MachineName has all the appropriate permissions

to be able to connect to the server. This is the default Windows account setunder IIS settings. If needed, add the IUSR_MachineName account to the

correct Windows user group that grants read/write access to this account. Formore details on the various permissions that need to be granted to this

account, see  http://support.microsoft.com/kb/271071 .

Case 2: Server Returns No Results

Problem

App connects to server, but all property runs return no results.

Cause

SQL server used by Aspen Properties Enterprise Database is not running ornot reachable from Aspen Properties Mobile server.

Solution

Log on directly on the Aspen Properties Mobile server and run  Aspen

Properties Database Configuration Tester  to diagnose this failure. See Aspen Engineering Installation Guide  and/or help for Aspen Properties

Database Manager for more information.

Case 3: Installation Appears to Succeed butServer Does Not Work

ProblemWith a newly installed Aspen Properties Mobile server, no clients can connect.

Note: First check the additional causes for connection failures in  App Cannot

Connect to Server, above.

Cause 1

Web service extensions are not configured for IIS.

Solution 1

In the  Internet Information Services  control panel, ensure that web

service extensions are enabled. The exact procedure for this varies withdifferent versions of IIS; see IIS documentation for details.

Cause 2

DCOM configuration does not permit Aspen Properties Mobile server to launch

Aspen Properties.

Page 202: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 202/214

202   9  Troubleshooting

Solution 2

1   Run   dcomcnfg.

2   In the tree, navigate to Component Services | Computers | MyComputer | DCOM Config | APropCOMServer.

3   Right-click  APropCOMServer  and click  Properties.

4   Click the Security  tab.5   In the  Launch and Activation Permissions  frame,  Customize  should

be selected. Click  Edit.

6   Depending on the version of IIS, you should see in the list of accounts

either  ASP.NET Machine Account  on the local machine  or  NETWORK

SERVICE on the local machine. Click this account name.

7   This account should have Local Launch  and  Local Activationpermissions. Ensure the boxes for these permissions are checked.

8   Click  OK  to close all the dialog boxes.

Troubleshooting Aspen OLI

Note: The Aspen OLI Interface is a subcomponent of the Aspen Plus andAspen Properties installations, not Aspen OLI.

Error messages resulting from the Software License Manager’s not finding a

license, and/or the OLI Security system’s not installing correctly will clearlyidentify which one is not functioning properly.

If the Software License Manager is not functioning correctly, the errormessage displayed on the Aspen OLI control panel will be as shown below:

Similarly, incorrect functioning of the OLI Security System will refer to the “OLI Security” and “OLI Engine” in the error messages. Both types of 

messages are shown below:

Page 203: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 203/214

9 Troubleshooting 203

Dongle Not Attached Properly

You see an error message from the OLI Security System indicating that thedongle is not attached properly. In the OLI Security Error figure above, the

red text indicates “key not initialized” 

SolutionCheck the dongle to make sure it is attached to your computer firmly. Also,ensure that the dongle is the first one in the port if you have more than one

dongle attached to this same port.

Page 204: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 204/214

Page 205: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 205/214

9 Troubleshooting 205

2   ARSS must be added to the application exceptions list in theWindows Firewall settings.

3   The port (8093 by default) that ARSS uses for communication also

needs to be added to this list.

Comments 1   If communication between client and server is still not working, thenyou can test whether the firewall settings are the problem by

temporarily turning off the firewall on your server and see if thatenables communication.

2   If you are still having trouble communicating with the ARSS, thenturn off User Account Control. This can be accessed in the  UserAccounts section of Control Panels.

Troubleshooting Aspen Simulation

Workbook

When running Excel with Aspen Simulation Workbook, you may encounter the

following problems.

Problem   After installing Aspen Simulation Workbook, the Simulation Workbooktoolbars do not appear in Excel 2003.

Cause   You may have clicked the mouse on other objects while the system wastrying to establish a connection.

Solution   In Excel, click View | Toolbars  to see a list of the toolbars. Click theAspen Simulation Workbook Design and Aspen Simulation WorkbookRun toolbars to make them active. If the toolbars are not included inthe list, Excel may have disabled Aspen Simulation Workbook. Go to thenext item in this table.

Problem   After installing Aspen Simulation Workbook, the  Simulation WorkbookToolbars are not available in the toolbar list, and the  Aspen  menu doesnot appear on the Excel pull-down menu structure. Similarly, for Excel2007 and later, the Aspen ASW ribbon bar tab is not present.

Cause   Excel may have disabled Aspen Simulation Workbook.

Solution To check:

For Excel 2003:

1   Open Excel.

2   Click  Help | About Microsoft Excel.

3   Click  Disabled Items. If Aspen Simulation Workbook appears inthe list of disabled items, remove it.

For Excel 2007:

1   Open Excel.

2   Click the Microsoft Office Button (round, large button located at topleft of Excel).

3   Select  Excel Options.

4   Select   Add-ins.

5   Select  Manage: Disabled Addins; then click the  Go  button

6   If Aspen Simulation Workbook appears in the list of disabled items,

remove it.

Page 206: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 206/214

206   9  Troubleshooting

Problem   After installing Aspen Simulation Workbook, the  Aspen SimulationWorkbook  Toolbars are not available in the toolbar list and the Aspenmenu does not appear on the Excel pull-down menu structure.

Similarly, for Excel 2007 and later, the Aspen ASW ribbon bar tab is notpresent.

Cause   This usually happens if the workbook is not registered correctly and fails

to load. This may have occurred because Excel was open when theworkbook was installed.

Solution   Users (running as administrators) can manually register AspenSimulation Workbook using the following command from a  DOS  window(Note: Shut down all instances of Excel before running this command):

regsvr32 "c:\Program Files\AspenTech\ Aspen Simulation Workbook

V7.3\ASWXLAddinLoader.dll"

Problem   After installing Aspen Simulation Workbook, the  Simulation WorkbookToolbars are not available in the toolbar list and the  Aspen  menu doesnot appear on the Excel pull-down menu structure. Similarly, for Excel2007 and later, the Aspen ASW ribbon bar tab is not present.

Cause   Aspen Simulation Workbook Add-In may be disabled.Solution To check:

1   Close Excel.

2   Open Aspen Simulation Workbook Add-In Manager, which isavailable from the   AspenTech | Operation Support V7.3 (orProcess Modeling V7.3) | Aspen Simulation Workbook V7.3Start menu.

3   If Aspen Simulation Workbook V7.3 is cleared, select the check boxto the left; then click  OK.

Problem   After installing Aspen Simulation Workbook, the  Aspen SimulationWorkbook Toolbars are not available in the toolbar list and the  Aspen

menu does not appear on the Excel pull-down menu structure.Similarly, for Excel 2007 and later, the Aspen ASW ribbon bar tab is notpresent.

Cause   This usually happens if the workbook is not registered correctly and failsto load. This may have occurred because Excel was open when theworkbook was installed.

Solution   These steps will re-register the Aspen Simulation Workbook Add-in withExcel:

1   First close all existing instances of Excel.

2   Go to  Start | Program | AspenTech | Operation Support V7.3(or Process Modeling V7.3) | Aspen Simulation Workbook |

Aspen Simulation Workbook Add-in Manager.

3   If Aspen Simulation Workbook V7.3 is cleared in the AspenSimulation Workbook COM Add-in Selector, select it and click  OK.

4   If Aspen Simulation Workbook V7.3 is selected, clear it and click  OK;rerun the  Aspen Simulation Workbook Add-in Manager  and re-select Aspen Simulation Workbook V7.3

Page 207: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 207/214

9 Troubleshooting 207

Troubleshooting Aspen Solubility Modeler

When launching Aspen Solubility Modeler, you may encounter the followingproblem.

Problem   While launching Aspen Solubility Modeler, you get the error message"Compile error in hidden module: This Workbook."

Cause   Aspen Properties V7.3 add-in is not registered.

Solution   See Configuring an Aspen Solubility Modeler Installation  for

complete instructions for registering the Aspen Properties V7.3 add-in inExcel.

Page 208: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 208/214

Page 209: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 209/214

10 Glossary 209

10 Glossary

The following terms and definitions are important for the installation,verification, configuration, modification, repair, and removal of Aspen

Engineering products.

Term Definition

DCOM (DistributedComponent Object Model)

DCOM is a Microsoft technology for distributedcomputing. It is an extension of Component ObjectModel (COM), which defines how components and theirclients interact. DCOM allows one client application toremotely start a DCOM server object on anothermachine and invoke its methods.

Documentation DVD The DVD that contains all documentation, help files,and so on for the aspenONE  release.

OLE DB A specification for a set of data access interfacesdesigned to enable a multitude of data stores of alltypes and sizes to work together seamlessly. Theseinterfaces comprise an industry standard for dataaccess and manipulation that can ensure consistency

and interoperability in a heterogeneous environment of data and data types.

Role A grouping of logical users in order to ease themaintenance of assigning access rights. Control listsmay be assigned either to individual users, or to groupsto which users belong.

Role-Based Security Role-based security is used to authorize andauthenticate users of AspenTech applications and datasources. By assigning users to roles that define workactivities, administrators can grant security privileges tomembers of a given role instead of individual users.

Use Aspen Framework (AFW) Server or Aspen LocalSecurity (ALS) to establish roles and associate users

with them.Server   installation Installs files on a central server machine.

SLM The Aspen Software License Manager

Standard installation Installs all files to the local hard drive of a computer.

Page 210: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 210/214

210   10  Glossary

Page 211: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 211/214

Index 211

Index

.

.NET Framework Error, 188

A

Additional RequirementsAspen Economic Evaluation, 31Aspen Process Manual, 37

Additional Software RequirementsAspen Custom Modeler, 30Aspen OnLine, 32

Aspen Plus, 35, 37, 38

Aspen Plus Dynamics, 36Aspen Properties, 37Aspen Properties Enterprise

Database, 38Aspen Properties Mobile, 38Aspen ACOL

verifying, 137

Aspen Adsorptionupgrade preparation, 168verifying, 119

Aspen Adsorption, 26, 42, 59, 61,

78, 81, 115Aspen Adsorption, 119Aspen Adsorption Additional

Requirements, 28Aspen Basic Engineering, 43, 44,

55, 59, 60, 86, 88, 92, 192troubleshooting, 192

Aspen Basic Engineering, 28, 42Aspen Basic Engineering, 55Aspen Basic Engineering, 75

Aspen Basic Engineering, 81Aspen Basic Engineering, 115Aspen Basic Engineering

Installation Notes, 85

Aspen Basic Engineering StandardInstallation Notes, 85

Aspen Batch Distillation

configuring, 124

verifying, 124Aspen Batch Distillation, 42, 115

Aspen Batch Process Developer,

115Aspen Batch Process Developer,

26, 42

Aspen Batch Process Developer

Project Filesupgrading, 169

Aspen BatchSepupgrade preparation, 168

Aspen Chromatography, 26, 32,42, 59, 61, 78, 81, 115

upgrade preparation, 168Aspen Custom Modeler, 26, 32, 42,

60, 61, 78, 81, 100, 115, 127,

129product requirements, 30

upgrade preparation, 168Verifying the Server Installation,

127

Aspen Distillation Synthesis, 115Aspen Economic Evaluation, 26,

42, 44, 60, 115

product requirements, 31

Aspen Energy Analyzer, 115Aspen Energy Analyzer, 42

Aspen Energy Analyzer, 26Aspen Engineering DVD, 45, 61,

171, 180Aspen Flare System Analyzer, 26,

42, 116

Aspen HTFS+, 115Aspen HYSYS, 26, 42, 60, 116

Page 212: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 212/214

212   Index

Aspen HYSYS Dynamics Runtime,

18

Aspen HYSYS Refining, 26, 42Aspen HYSYS Refining V7.2, 116Aspen HYSYS Upstream, 26, 43

Aspen HYSYS Upstream, 116

Aspen OLI, 108, 144, 202Aspen OLI Interface, 144

verifying, 144Aspen OLI Interface Installation

Notes, 106Aspen Online, 82, 100

installation notes, 100

Aspen OnLine, 26, 32, 33, 43, 55,60, 71, 82, 116, 137, 139, 168

product requirements, 32upgrade preparation, 168

upgrading, 168verifying, 139

Aspen Online Deployment, 26Aspen OTS Framework, 26Aspen Plus, 26, 30, 31, 32, 35, 36,

43, 61, 100, 104, 108, 116,

129, 140, 143, 144, 145, 169

installing Aspen Plus Optimizer,35

product requirements, 35, 37, 38upgrade preparation, 168

Aspen Plus CatCracker, 26, 116Aspen Plus CatCracker, 43

Aspen Plus Dynamics, 26, 30, 43,

60, 61, 78, 81, 116, 148upgrade preparation, 168

verifying, 148Aspen Plus Dynamics

product requirements, 36Aspen Plus Hydrocracker, 26, 43,

116

Aspen Plus Hydrotreater, 27, 43,116

Aspen Plus Optimizer, 35Aspen Plus Reformer, 43

Aspen Plus Reformer, 27Aspen Plus Reformer, 116

Aspen Polymers Plus, 27, 43Aspen Process Manual, 27, 60, 116

installation notes, 110

Aspen Process Tools, 27, 43, 116Aspen Properties, 27, 37, 43, 61,

116, 119, 128, 149, 153, 156,157, 169

upgrade preparation, 168

Aspen Properties Enterprise

Database, 38

Aspen Properties Mobile, 38configuring, 150verifying, 150

Aspen Remote Simulation Server,

204Aspen Remote Simulation Service,

27Aspen Simulation Workbook, 27,

205product requirements, 38

Aspen Solubility Modeler, 27, 207

Aspen Utilities, 39, 100, 113, 164,165

B

Basic Engineering, 26, 28

Batch Process Developertroubleshooting, 194

C

Change Current DestinationLocation dialog box, 53, 69

Changing Product/Subfeature

Folders, 52, 69Checking Product Specific

Requirements and

Dependencies, 26client-server installation

client installation, 77Completing the Setup, 59, 75, 178,

185Computer Configuration Type

dialog box, 51, 67, 85, 88, 90,

176, 184

configuringAspen OnLine, 137

Aspen Properties Mobile, 150

Configuring Aspen BasicEngineering, 123

Configuring Aspen OnLine, 137

Configuring Aspen Products atInstall Time, 55, 71

D

documentation, 10

E

Exchanger Design and Rating, 42

Page 213: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 213/214

Index 213

F

Feature Selection dialog box, 52,54, 68, 69, 70, 85, 88, 167

H

Hypcalc.dll, 99

I

installation account privilegestroubleshooting, 187

installation accounts

troubleshooting, 187installation notes

Aspen Basic Engineering, 85

Aspen Online, 100Aspen Process Manual, 110

Installation Options, 42

Installing Aspen Products, 41

M

Microsoft Excelusing after removing Aspen Basic

Engineering, 186

O

OLI Alliance Suite, 99, 108

OLI HardLock Security Key, 98,107

OLIRegClient.dll, 100OLIRegclient.rci, 100

P

Product Upgrade Task Summary,168

Program Maintenance screen, 50,

66ProVision, 87, 89

Ready to Install, 57, 73Recommended Installation

Sequence, 39

Repairing or Modifying Products,

169

T

troubleshooting

Aspen Basic Engineering, 192Batch Process Developer, 194

checking installation account

privileges, 187error messages (client-server),

188

Troubleshooting Aspen Economic

Evaluation, 195

U

upgradingAspen Batch Process Developer

Project Files, 169upgrading

Aspen Online, 168

Upgrading Aspen Products, 169

Using the FORTRAN Compiler withAspen Plus, 143

V

Valid Aspen Product InstallationOptions, 42

verifyingAspen ACOL, 137

Aspen Adsorption, 119Aspen OLI Interface, 144Aspen Plus Dynamics, 148Aspen Properties Mobile, 150

Verifying an Aspen

Chromatography Installation,127

Verifying an Aspen OnLine

Installation, 139

W

Windows

adding server accounts, 76windows server 

adding Windows Server accounts, 76

Page 214: Aspenengineering Install Guide Suitev7_3-Inst

8/12/2019 Aspenengineering Install Guide Suitev7_3-Inst

http://slidepdf.com/reader/full/aspenengineering-install-guide-suitev73-inst 214/214