II-270 EXAMINATION
II-278 SYSTEM CONFIGURATIONThe radioscopic examination system shall, as a mini-
mum, include the following:(a) radiation source(b) manipulation system(c) detection system(d) information processing system(e) image display system(f) record archiving system
II-280 EVALUATION
II-286 FACTORS AFFECTING SYSTEMPERFORMANCE
The radioscopic examination system performance qual-ity is determined by the combined performance of thecomponents specified in II-278. (See SE-1255, 6.1.)When using wire IQIs, the radioscopic examination sys-
tem may exhibit asymmetrical sensitivity, therefore, thewire diameter axis shall be oriented along the axis of theleast sensitivity of the system.
II-290 DOCUMENTATION
II-291 RADIOSCOPIC TECHNIQUE INFORMATIONTo aid in proper interpretation of the radioscopic exam-
ination data, details of the technique used shall accompanythe data. As a minimum, the information shall include theitems specified in T-291 when applicable, II-221, and thefollowing:
(a) operator identification(b) system performance test data
II-292 EVALUATION BY MANUFACTURERPrior to being presented to the Inspector for acceptance,
the examination data shall be interpreted by the Manufac-turer as complying with the referencing Code Section. TheManufacturer shall record the interpretation and disposi-tion of each weldment examined on a radiographic inter-pretation review form accompanying the radioscopic data.
2013 SECTION V ARTICLE 2