II-270 EXAMINATION II-278 SYSTEM CONFIGURATION The radioscopic examination system shall, as a mini- mum, include the following: (a) radiation source (b) manipulation system (c) detection system (d) information processing system (e) image display system (f) record archiving system II-280 EVALUATION II-286 FACTORS AFFECTING SYSTEM PERFORMANCE The radioscopic examination system performance qual- ity is determined by the combined performance of the components specified in II-278. (See SE-1255, 6.1.) When using wire IQIs, the radioscopic examination sys- tem may exhibit asymmetrical sensitivity, therefore, the wire diameter axis shall be oriented along the axis of the least sensitivity of the system. II-290 DOCUMENTATION II-291 RADIOSCOPIC TECHNIQUE INFORMATION To aid in proper interpretation of the radioscopic exam- ination data, details of the technique used shall accompany the data. As a minimum, the information shall include the items specified in T-291 when applicable, II-221, and the following: (a) operator identification (b) system performance test data II-292 EVALUATION BY MANUFACTURER Prior to being presented to the Inspector for acceptance, the examination data shall be interpreted by the Manufac- turer as complying with the referencing Code Section. The Manufacturer shall record the interpretation and disposi- tion of each weldment examined on a radiographic inter- pretation review form accompanying the radioscopic data. 2013 SECTION V ARTICLE 2 19 No further reproduction or distribution is permitted.

description

ASME sec v index 63

Transcript of ASME SEC V-2013 63

  • II-270 EXAMINATION

    II-278 SYSTEM CONFIGURATIONThe radioscopic examination system shall, as a mini-

    mum, include the following:(a) radiation source(b) manipulation system(c) detection system(d) information processing system(e) image display system(f) record archiving system

    II-280 EVALUATION

    II-286 FACTORS AFFECTING SYSTEMPERFORMANCE

    The radioscopic examination system performance qual-ity is determined by the combined performance of thecomponents specified in II-278. (See SE-1255, 6.1.)When using wire IQIs, the radioscopic examination sys-

    tem may exhibit asymmetrical sensitivity, therefore, thewire diameter axis shall be oriented along the axis of theleast sensitivity of the system.

    II-290 DOCUMENTATION

    II-291 RADIOSCOPIC TECHNIQUE INFORMATIONTo aid in proper interpretation of the radioscopic exam-

    ination data, details of the technique used shall accompanythe data. As a minimum, the information shall include theitems specified in T-291 when applicable, II-221, and thefollowing:

    (a) operator identification(b) system performance test data

    II-292 EVALUATION BY MANUFACTURERPrior to being presented to the Inspector for acceptance,

    the examination data shall be interpreted by the Manufac-turer as complying with the referencing Code Section. TheManufacturer shall record the interpretation and disposi-tion of each weldment examined on a radiographic inter-pretation review form accompanying the radioscopic data.