AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English
-
Upload
askozia -
Category
Technology
-
view
74 -
download
0
Transcript of AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English
![Page 1: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/1.jpg)
![Page 2: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/2.jpg)
Your hosts todayMarkus Ehlers Dietmar Steinbrücker
![Page 3: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/3.jpg)
SNOM M700 DECT
![Page 4: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/4.jpg)
Short introduction to DECT Multi-Cell
![Page 5: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/5.jpg)
Understanding Multi-Cell Coverage: 100 m indoor, 300 m outdoor
![Page 6: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/6.jpg)
M700 base stations
Understanding Multi-Cell
Coverage
• 100 m indoor / 300 m outdoor
• Roaming among multiple BS
SIP registrations
• Max. 30 per base station• Distributed
automatically BS
Voice Channels per Base
• Up to 8 concurrent calls (4 HD audio)
100 m100 m
1-30
Max. 1,000
4-8
Max. 200
![Page 7: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/7.jpg)
SIP up to 30 SIP up to
30 SIP up to 30
Up to 30, but we need only one additional handset
Base station calculationHow many BS do you need for 91 handsets?
• SIP Registrations: 91/30 = 3 x 30 + 1 x 30 –> 4 Bases• Best practices for heavy call usage: 8 per Base –> 11
Bases
![Page 8: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/8.jpg)
DECT assessment @ location
![Page 9: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/9.jpg)
Assessment
• Base with local power• Handset in assesment
mode
![Page 10: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/10.jpg)
Assessment Goals
• Redundancy per Base• Coverage approx. -70dB to be safe• Floor to floor , building to building connections• Full air coverage auto-DECT tree
![Page 11: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/11.jpg)
Assessment Do‘s
•Handset / Menu, *IP* (*47*)• Select your base station• 2x Call button for audio loop-back with your base• Look for good reception to two other bases•Direct hall-way coverage (tends to be very far and safe)• floor to floor• Very near Fire safety door / behind elevator / open space backyard
![Page 12: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/12.jpg)
Assessment Dont‘s
•Guess-work base placement – always assess!• Non redundancy radio coverage -80dB• Direct path base station over the air DECT tree• Human bodies coverage reduction• Underestimate concurrent call areas•Multi primary where not necessary
![Page 13: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/13.jpg)
SIP up to 30 SIP up to
30 SIP up to 30
Up to 30
Snom M700 Multi-CellLiving Cell
![Page 14: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/14.jpg)
Up to 1000
…Air sync No Air sync
Over the air syncMandatory for Roaming
![Page 15: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/15.jpg)
• There is sync over LAN, but its limited to max bases-1• In fact, hardly a limit
Multi Primary
Up to 1000
…Primary
LAN sync
More than one data master on the LAN
![Page 16: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/16.jpg)
• The master base stations MUST NOT „see each other“ over the air. This will cause syncronisation chaos within the Multi-Cell installation
Multi PrimaryWhat is necessary to know
![Page 17: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/17.jpg)
Configuration
![Page 18: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/18.jpg)
Configuration
![Page 19: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/19.jpg)
Configuration
![Page 20: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/20.jpg)
Configuration
![Page 21: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/21.jpg)
Configuration
![Page 22: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/22.jpg)
Configuration
![Page 23: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/23.jpg)
Configuration
![Page 24: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/24.jpg)
Configuration
![Page 25: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/25.jpg)
Configuration
![Page 26: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/26.jpg)
Configuration
![Page 27: AskoziaPBX and snom M700 DECT for workplace mobility - webinar 2016, English](https://reader031.fdocuments.in/reader031/viewer/2022022201/589d99531a28abfb3d8b5613/html5/thumbnails/27.jpg)
Configuration