Aseptic Technique: Media and Equipment

38
Aseptic Technique: Media and Equipment

description

Aseptic Technique: Media and Equipment. Growth Medium. A growth medium or culture medium is a liquid or gel designed to support the growth of microorganisms or cells The most common growth media for microorganisms are nutrient broths and agar plates. Defined Media. - PowerPoint PPT Presentation

Transcript of Aseptic Technique: Media and Equipment

Page 1: Aseptic Technique: Media and Equipment

Aseptic Technique:Media and Equipment

Page 2: Aseptic Technique: Media and Equipment

Growth Medium• A growth medium or culture medium is

a liquid or gel designed to support the growth of microorganisms or cells

• The most common growth media for microorganisms are nutrient broths and agar plates

Page 3: Aseptic Technique: Media and Equipment

Defined Media• An important distinction between

growth media types is that of defined versus undefined media

• A defined medium will have known quantities of all ingredients

Page 4: Aseptic Technique: Media and Equipment

Undefined Media• An undefined medium has some

complex ingredients that consist of a mixture of many chemical species in unknown proportions

• Undefined media are sometimes chosen based on price and sometimes by necessity - some microorganisms have never been cultured on defined media.

Page 5: Aseptic Technique: Media and Equipment

Undefined Media• We will use this in the lab

• Nutrient Agar contains:– Pancreatic digest of gelatin– Beef Extract– Agar

Page 6: Aseptic Technique: Media and Equipment

Forms of Culture• The most common growth media for

microorganisms are nutrient broths (liquid in a test tube)

• Liquid media are often mixed with agar and poured into petri dishes to solidify

• These agar plates provide a solid medium on which microbes may be cultured. They remain solid, as very few bacteria are able to decompose agar.

Page 7: Aseptic Technique: Media and Equipment
Page 8: Aseptic Technique: Media and Equipment
Page 9: Aseptic Technique: Media and Equipment

Slants• There are several reasons a slant is

best for culture storage:• 1) Surface area – slant increases it• 2) Size – test tubes smaller to store• 3) Moisture – won’t dry out• 4) Ease – once the microorganism is

transferred, you can store it for up to 6 months in a refrigerator

Page 10: Aseptic Technique: Media and Equipment
Page 11: Aseptic Technique: Media and Equipment

Aseptic Technique• Aseptic technique refers to a procedure

that is performed under sterile conditions

• This includes medical and laboratory techniques (such as with microbiological cultures)

• It includes techniques like flame sterilization (Bunsen burner)

Page 12: Aseptic Technique: Media and Equipment

Aseptic Technique• Sterile surfaces must be protected from

microbes in the air or on non-sterile surfaces

• In sterile technique, only sterile surfaces touch other sterile surfaces and air exposure is kept to a minimum

Page 13: Aseptic Technique: Media and Equipment

Aseptic Technique

• It is important in microbiology to work with pure cultures

• This is difficult because the world around us is covered with MO’s (even on dust particles in the air)

• In order to protect broth, plates, slants and pure cultures from MO’s around us, we practice aseptic techniques

Page 14: Aseptic Technique: Media and Equipment

Aseptic Technique• In this class you will need to practice

sterile technique when we inoculate a pure culture into fresh medium (tube of sterile broth or an agar plate)

Page 15: Aseptic Technique: Media and Equipment

Aseptic Technique• “A” = Negative prefix• “Septic” = Infection• All techniques and procedures which

prevent contamination.

Page 16: Aseptic Technique: Media and Equipment

Safe Patterns• Safe patterns include:

–Standard Lab Rules– Inoculating Techniques–Use and Disposal of Equipment–Washing Hands

Page 17: Aseptic Technique: Media and Equipment

Safe Patterns• Sterilize all materials before beginning

Page 18: Aseptic Technique: Media and Equipment

Safe Patterns• Spray the lab top down with a

commercial disinfectant or a 10% bleach solution and allow this to stand for a minute. You may then wipe down the bench with the paper towel.

Page 19: Aseptic Technique: Media and Equipment

Safe Patterns• Wash hands before and after lab.

Page 20: Aseptic Technique: Media and Equipment

Safe Patterns• You should have only the materials

you'll need and the written lab procedures on your bench top or desk.

Page 21: Aseptic Technique: Media and Equipment

Safe Patterns• Keep petri dishes and test tubes

covered as much as possible. • If top must be removed completely do

not LAY IT on the lab top. This lowers the probability of contamination and prevents “false positive” results.

Page 22: Aseptic Technique: Media and Equipment

Safe Patterns• Hold bottles and tubes at an angle to

minimize the amount of airborne microbes that can fall into them (blue circle). Remove the caps as shown above and do not set the caps down. Keep the mouth of the facing cap down (red circle).

Page 23: Aseptic Technique: Media and Equipment

Safe Patterns• When using metal inoculating loops, HEAT

the entire piece of metal of the inoculation instrument in the flame: it should be RED HOT. Be sure to COOL your inoculation instrument before picking the inoculum (broth or agar).

Page 24: Aseptic Technique: Media and Equipment

Safe Patterns• To inoculate a Petri plate: Lift one edge

of the Petri plate cover to gain access to the culture medium. Keep the cover over the plate bottom to prevent dust and microbes from falling onto the agar.

Page 25: Aseptic Technique: Media and Equipment

Safe Patterns• Report spills to me immediately

• Cover the spill with paper towels and squirt disinfectant onto the towels. Wait 20 minutes then clean up the spill.

Page 26: Aseptic Technique: Media and Equipment

Safe Patterns• Label all test tubes and petri plates with

your name (initials), date, and name of organism BEFORE you add any solutions, bacteria, etc. 

Page 27: Aseptic Technique: Media and Equipment

Safe Patterns• Do not dump ANY microbial

suspension down the drain or in the trash can. I will collect them for proper disposal.

Page 28: Aseptic Technique: Media and Equipment

Safe Patterns• Place test tubes in racks

when working at your table: never lay the tubes down—they leak.

• Keep test tube caps and petri dish covers on media to reduce contamination (matters not whether it is sterile media or already cultured).

Page 29: Aseptic Technique: Media and Equipment

Safe Patterns• All agar plates are

incubated UPSIDE DOWN to reduce bacterial contamination and to reduce the possibility of water condensation that may be on the lid dropping onto the agar, causing fluid to run across the agar medium.  

Page 30: Aseptic Technique: Media and Equipment

Media• Sterilize after preparation, in

storage, or working containers. Handle aseptically.

• If no goofs – Sterile indefinitely

Page 31: Aseptic Technique: Media and Equipment

E. Autoclave• Pressurized steam• Water boils at 100ºC, but if pressure is

increased the boiling point rises– At 15 PSI the Boiling Point = 121ºC– At 20 PSI the Boiling Point = 126ºC

• Minimum = 15 minutes @ 15 PSI• A pressure cooker is the same as an

autoclave

Page 32: Aseptic Technique: Media and Equipment

Boiling• 100ºC kills most MO, fungi, and viruses

but a few are resistant.– Example: Inf. Hepatitis, Endospores

• But very good nonprofessional use

Page 33: Aseptic Technique: Media and Equipment

EquipmentTechnique depends on article:

Does it burn or melt?

Do you want it back?

Page 34: Aseptic Technique: Media and Equipment

Equipment1. Autoclave• If it fits into machine and won’t melt• 15 minutes @ 121ºC (15 PSI) minimum

Page 35: Aseptic Technique: Media and Equipment

Equipment2. Boiling• Never in a lab

Page 36: Aseptic Technique: Media and Equipment

EquipmentOven• Dry heat used for metal and glass• 90 minutes @ 170ºC minimum

Page 37: Aseptic Technique: Media and Equipment

EquipmentIncineration – Burning• 1000ºC Plus• Loops, test tubes

Page 38: Aseptic Technique: Media and Equipment

Equipment5. Presterilized Equipment• Usually plastic and paper materials• Gas: Ethylene Oxide• Irradiation