Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life...

47
Asbestos Reinspection Report (with Priority Assessments) Gorringe Park Primary Sandy Lane, Mitcham, Surrey, CR4 2YA 56886 / 23151 Project Number: B-82297 Issue Date: 1 st March 2019 Issue No: 1 Client Contact: Life Environmental Services Ltd Contact: Andy Sweeney London Borough of Merton Merton Civic Centre London Road Morden Surrey SM4 5DX 4 Duckett’s Wharf South Street Bishop’s Stortford Hertfordshire CM23 3AR Tel: 02085453382 Tel: 01279 503117 Fax: Fax: 01279 503162

Transcript of Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life...

Page 1: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

Asbestos

Reinspection Report (with Priority Assessments)

Gorringe Park Primary

Sandy Lane,

Mitcham, Surrey,

CR4 2YA

56886 / 23151

Project Number: B-82297

Issue Date: 1st

March 2019

Issue No: 1

Client Contact:

Life Environmental Services Ltd Contact: Andy Sweeney

London Borough of Merton Merton Civic Centre London Road Morden Surrey SM4 5DX

4 Duckett’s Wharf South Street Bishop’s Stortford Hertfordshire CM23 3AR

Tel: 02085453382 Tel: 01279 503117 Fax: Fax: 01279 503162

Page 2: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

Life Environmental - Survey Report Guide

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 2 of 44

This guide explains the Section content of the survey report. Failure to use the information provided in the report correctly may result in incorrect information or assumptions being obtained. Section 1.0 Executive Summary The Executive Summary contains details of the scope and extent of the works. The reader must ensure that the scope covers the required areas and that any variations do not impact on any proposed works or management of the site. All areas of no access should be considered as containing asbestos until proven otherwise. Recommended Actions provides a summary of all identified and presumed asbestos containing materials (ACMs). ACMs are listed by recommendation with those requiring urgent attention listed first. The Asbestos Register presents ACMs by building, floor & location. It provides a detailed list of all locations included within the survey where positive samples have been taken or items are presumed to contain asbestos. Items physically sampled will show the asbestos type within the analysis column. Items cross referenced (strong presumption) have their asbestos type determined by the sample result of materials of similar appearance and use that have been sampled elsewhere on site. These will show the analysis proceeded by X. Strongly Presumed samples are items that the surveyor was unable to sample but the materials are similar in appearance and use to known asbestos-containing materials and hence they are confirmed as containing asbestos. Presumed items are those that the surveyor was unable to sample or inspect adequately to confirm the presence of asbestos, as such there is a potential for asbestos being present and the item is presumed to contain asbestos. A Material Assessment algorithm has been completed for all positive samples. It should be noted that to enable an accurate Priority Assessment to be undertaken this requires a detailed knowledge of the property. The responsibility for this lies with the dutyholder, although Life Environmental can assist with the provision of information or generic assessments where agreed. Recommendations within this report are based on the condition of the asbestos and the Material Assessment. Prior to carrying out these recommendations consideration should be given to the Priority Assessment Algorithm. Section 2.0 Introduction The Introduction provides a general overview of the purpose, aims and type of survey undertaken. It also presents Project particulars and Quality Assurance. Section 3.0 Survey Findings – Survey Reinspection Data Sheets Survey Data Sheets contains detailed information on all suspect items with a photographic record of each item. Section 4.0 – Survey Findings – Certificate & Schedule of Additional Bulk Samples This section provides analysis information and results of any additional samples taken. Appendix 1 - Definitions & Recommended Guidance These contain a general guidance relating to Samples, Assessments and Recommendations and a detailed Risk Assessment explanation. Appendix 2 - Material & Priority Assessment algorithms These contain a general guidance relating to detailed Risk Assessment explanation. Appendix 3 - Survey Drawings All locations will be given a unique reference number which corresponds to the location detailed within the Asbestos Register. The drawings highlight areas containing positive information and areas of no access. In the case of planned works, a check should always be made of adjacent areas.

Page 3: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

1. Introduction

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 3 of 44

1. Introduction

a. Purpose & Aim of Survey

b. Quality Assurance

2. Executive Summary

a. Revisions

b. Recommended Actions c. Asbestos Register

3. Reinspection Data Sheets

4. Additional Bulk Samples

Appendices:

Appendix 1 - Definitions & Recommended Guidance

Appendix 2 - Material & Priority Assessment algorithms

Appendix 3 - Survey Drawings

Page 4: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

1. Introduction

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 4 of 44

Life Environmental Services Ltd received an order of confirmation to undertake a Reinspection Survey from London Borough of Merton. This order has been accepted on the basis of the original Quotation and our terms and conditions of business. This reinspection is subject to copyright and protected by copyright law. The brief for these works was to carry out a reinspection of the Asbestos Containing Materials (ACMs) within the Gorringe Park Primary. The reinspection is based upon the previous report ref B-70564 and B-76460 This reinspection considered any damage and disturbance to items identified in the above survey. Every effort has been made to access any areas that were previously not accessible in the original survey. Where such locations have still not been accessed, asbestos should be presumed to be present within these areas. Each section of this report focuses on one or two aspects; no section should be taken and read as a stand-alone document. It is imperative that each section is read in conjunction with each other. This reinspection report forms an addendum to the original survey. The original survey report should be referred to for the following items of information:

Information on the original survey methodology/caveats

Original laboratory bulk analysis certificate of analysed samples

Original drawings

It should be noted that this report is not intended as a Scope of Works for asbestos removal and that a detailed technical document could be provided upon request. If any maintenance works are to be undertaken within the areas not accessed then a further survey and assessment should be carried out prior to these works.

Client Details: London Borough of Merton

Date(s) of Survey: 21-February-2019

Surveyor(s): Lead Surveyor(s): Neil De’ath

Report Prepared by: Stephanie Goody 1st March 2019

Quality Control by: Neil De’ath 1st March 2019

Life Environmental Project Manager:

Andy Sweeney

Page 5: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

2. Executive Summary

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 5 of 44

a. Revisions

The following table summarises the items removed between the most recent re-inspection and it’s predecessor.

No items have been removed since the last inspection.

b. Recommended Actions Detailed below is guidance on actions to be taken to prevent potential exposure to ACMs. There follows a summary of all reinspected asbestos items that require further action in order that they can be managed safely Please note that if additional samples or suspect items have been identified during the reinspection these will be detailed in Section 3 (Reinspection Data Sheets) of this report only and will not be detailed below or within any part of Section 2 of the report. Please note the colour coding is based on the recommendation only and is not determined by the Material Assessment scores, these are explained within the original asbestos survey report. Some lower risk items may be recommended for removal based on its location or usage rather than the score only. Please contact Life Environmental Services Ltd for advice in dealing with any asbestos in poor, unsealed or damaged condition or for assistance in developing your management plan and scheduling reinspections.

Manage and Re-inspect

ACMs have been identified which are in good condition. A management policy and plan need to be implemented to manage these materials safely.

Building Floor Location Number

and Name Item Material

Level of Identification

Risk Assessment

Caretakers

accommodation 0 004 - Toilet Floor Tiles Floor Tiles SP 2

Caretakers accommodation

0 005 - Lobby Floor Tiles Floor Tiles SP 2

Gorringe Park Primary

0 002 - Lounge Panel To Fireplace

Insulating Board

SP 5

Gorringe Park Primary

0 006 - Ict Suite Board To Ceiling

Insulating Board

SP 6

Gorringe Park Primary

0 007 - Store Floor Tiles Floor Tiles SP 2

Gorringe Park Primary

0 034 - Boys Toilet Door Header Panel

Insulating Board

SP 5

Gorringe Park Primary

0 034 - Boys Toilet Toilet Cistern X3

Reinforced Composites

SP 3

Gorringe Park Primary

0 036B - Girls Toilet Door Header Panel

Insulating Board

SP 5

Gorringe Park

Primary 0 037 - Store

Bitumen Adhesive

Below Carpet

Bitumen

Products SP 2

Gorringe Park Primary

0 041 - Heads Office

Bitumen

Adhesive Below Carpet

Bitumen Products

SP 2

Gorringe Park Primary

0 042 - Store Textured Coating

Textured Coating

SP 2

Gorringe Park Primary

0 045 - Hall Textured Coating

Textured Coating

SP 2

Page 6: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

2. Executive Summary

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 6 of 44

Manage and Re-inspect

ACMs have been identified which are in good condition. A management policy and plan need to be implemented to manage these materials safely.

Building Floor Location Number

and Name Item Material

Level of Identification

Risk Assessment

Gorringe Park

Primary 0 047 - Reception

Textured

Coating

Textured

Coating SP 2

Gorringe Park

Primary 0 059 - Store

Cement Fire

Place Surround

Cement

Products SP 3

Gorringe Park

Primary 0 061 - Boiler Room

Gaskets To

Pipework Gasket SP 5

Gorringe Park Primary

0 077 - Corridor Floor Tiles Floor Tiles SP 2

Gorringe Park Primary

0 077 - Corridor

Panel To

Electrical Cupboard

Insulating Board

SP 5

Gorringe Park Primary

0 119 - Corridor Door Header Panel

Insulating Board

SP 5

Gorringe Park Primary

1 063 - Store Floor Tiles Floor Tiles SP 2

Gorringe Park Primary

1 064 - Store Floor Tiles Floor Tiles SP 2

Gorringe Park Primary

1 065 - Classroom Floor Tiles Floor Tiles SP 2

Gorringe Park Primary

1 065 - Classroom Sink Pad Bitumen Products

SP 2

Gorringe Park Primary

1 073 - Toilet Toilet Cistern

Reinforced Composites

SP 3

Gorringe Park

Primary

Extern

al External - Gym

Damp Proof Course To

Gym

Bitumen

Products SP 2

Presumed Items

The following items have been presumed to contain asbestos where it was not possible to access the item in order to sample. These items must be treated as containing asbestos until access can be arranged in order to inspect or sample to confirm or refute the presence of asbestos.

Building Floor Location Number

and Name Item Material

Level of Identification

Risk Assessment

Caretakers accommodation

0 002 - Lounge

Bitumen Below Parquet

Flooring

Bitumen Products

P 2

Gorringe Park

Primary 0 002 - Classroom

Bitumen Below

Parquet Flooring

Bitumen

Products P 2

Gorringe Park Primary

0 004 - Electrical Intake

Flashguards Within Live Electrical

Services

Textile Rope & Yarn

P 4

Gorringe Park

Primary 0 008 - Classroom

Bitumen Below

Parquet Flooring

Bitumen

Products P 2

Gorringe Park Primary

0 009 - Classroom

Bitumen

Below Parquet Flooring

Bitumen Products

P 2

Gorringe Park Primary

0 010 - Classroom Bitumen Below

Bitumen Products

P 2

Page 7: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

2. Executive Summary

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 7 of 44

Presumed Items

The following items have been presumed to contain asbestos where it was not possible to access the item in order to sample. These items must be treated as containing asbestos until access can be arranged in order to inspect or sample to confirm or refute the presence of asbestos.

Building Floor Location Number

and Name Item Material

Level of Identification

Risk Assessment

Parquet Flooring

Gorringe Park

Primary 0 016 - Staff Room

Bitumen Below

Parquet Flooring

Bitumen

Products P 2

Gorringe Park Primary

0 030 - He

Bitumen

Below Parquet Flooring

Bitumen Products

P 2

Gorringe Park Primary

0 051 - Staff Room Bitumen Residue To Floor

Bitumen Products

P 2

Gorringe Park Primary

0 055 - Classroom Bitumen Residue To

Floor

Bitumen Products

P 2

Gorringe Park Primary

0 056 - Classroom Bitumen Residue To

Floor

Bitumen Products

P 2

Gorringe Park

Primary 0 057 - Classroom

Bitumen Residue To

Floor

Bitumen

Products P 2

Gorringe Park

Primary 0 059 - Store

Bitumen Residue To

Floor

Bitumen

Products P 2

Gorringe Park Primary

0 080 - Corridor

Bitumen

Below Parquet Flooring

Bitumen Products

P 2

Gorringe Park Primary

0 081 - Corridor

Bitumen Below Parquet

Flooring

Bitumen Products

P 2

Gorringe Park

Primary 0 082 - Corridor

Bitumen Below

Parquet Flooring

Bitumen

Products P 2

Gorringe Park Primary

0 085 - Corridor

Bitumen

Below Parquet Flooring

Bitumen Products

P 2

Gorringe Park Primary

1 068 - Classroom

Bitumen Below Parquet

Flooring

Bitumen Products

P 2

Gorringe Park Primary

1 077 - Staff Room

Bitumen

Below Parquet Flooring

Bitumen Products

P 2

All locations were accessible at the time of this survey.

Page 8: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

2. Executive Summary

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 8 of 44

c. Asbestos Register

Building

Flo

or

Location L

evel

of

Iden

tifi

cati

on

Item

Exte

nt

Material Assessment

Accessib

ilit

y

Pri

ori

ty

Assessm

en

t

Recommendation N

ext

Insp

ecti

on

Product Type Condition Surface

Treatment Asbestos

Type

To

tal S

co

re

Caretakers accommodation

0 002 - Lounge P

Bitumen Below Parquet

Flooring

17m² Bitumen Products

Good Condition

Composite

materials containing asbestos,

plastics, resins etc.

Chrysotile 2 Usually

inaccessible 1

No Access - Inspection Required

21 February 2020

Caretakers accommodation

0 004 - Toilet SP Floor Tiles 2m² Floor Tiles Good

Condition

Composite

materials containing asbestos,

plastics, resins etc.

Chrysotile 2 Usually

inaccessible 0

Manage & Re-inspect

21 February 2020

Caretakers accommodatio

n

0 005 - Lobby SP Floor Tiles 2m² Floor Tiles Good

Condition

Composite

materials containing asbestos,

plastics, resins etc.

Chrysotile 2 Usually

inaccessible 0

Manage & Re-inspect

21 Februar

y 2020

Gorringe Park Primary

0 002 - Lounge SP Panel To Fireplace

1m² Insulating Board Good

Condition Sealed AIB,

spray, textile etc. Amosite 5

Usually inaccessible

0 Manage & Re-inspect

21 February 2020

Gorringe Park

Primary 0 002 - Classroom P

Bitumen Below

Parquet Flooring

65m² Bitumen

Products

Good

Condition

Composite materials containing

asbestos, plastics, resins

etc.

Chrysotile 2 Usually

inaccessible 1

No Access -

Inspection Required

21

February 2020

Gorringe Park

Primary 0

004 - Electrical

Intake P

Flashguards Within Live

Electrical Services

1Lm Textile Rope &

Yarn

Good

Condition

Unsealed AIB, encapsulated

spray etc.

Chrysotile 4 Usually

inaccessible 0

No Access - Inspection

Required

21 Februar

y 2020

Gorringe Park Primary

0 006 - Ict Suite SP Board To Ceiling

9m² Insulating Board Low

Damage Sealed AIB,

spray, textile etc. Amosite 6

Usually inaccessible

0 Manage & Re-inspect

21

February 2020

Page 9: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

2. Executive Summary

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 9 of 44

Building

Flo

or

Location L

evel

of

Iden

tifi

cati

on

Item

Exte

nt

Material Assessment

Accessib

ilit

y

Pri

ori

ty

Assessm

en

t

Recommendation N

ext

Insp

ecti

on

Product Type Condition Surface

Treatment Asbestos

Type

To

tal S

co

re

Gorringe Park Primary

0 007 - Store SP Floor Tiles 14m² Floor Tiles Good

Condition

Composite

materials containing asbestos,

plastics, resins etc.

Chrysotile 2 Usually

inaccessible 1

Manage & Re-inspect

21 Februar

y 2020

Gorringe Park

Primary 0 008 - Classroom P

Bitumen Below

Parquet Flooring

30m² Bitumen

Products

Good

Condition

Composite materials containing

asbestos, plastics, resins

etc.

Chrysotile 2 Usually

inaccessible 1

No Access - Inspection

Required

21 Februar

y 2020

Gorringe Park

Primary 0 009 - Classroom P

Bitumen Below

Parquet Flooring

30m² Bitumen

Products

Good

Condition

Composite materials containing

asbestos, plastics, resins

etc.

Chrysotile 2 Usually

inaccessible 1

No Access -

Inspection Required

21

February 2020

Gorringe Park Primary

0 010 - Classroom P

Bitumen

Below Parquet Flooring

30m² Bitumen Products

Good Condition

Composite materials

containing asbestos,

plastics, resins etc.

Chrysotile 2 Usually

inaccessible 1

No Access -

Inspection Required

21

February 2020

Gorringe Park Primary

0 016 - Staff Room P

Bitumen

Below Parquet Flooring

25m² Bitumen Products

Good Condition

Composite materials

containing asbestos,

plastics, resins

etc.

Chrysotile 2 Usually

inaccessible 1

No Access -

Inspection Required

21

February 2020

Gorringe Park Primary

0 030 - He P

Bitumen

Below Parquet Flooring

30m² Bitumen Products

Good Condition

Composite materials

containing asbestos,

plastics, resins

etc.

Chrysotile 2 Usually

inaccessible 1

No Access - Inspection Required

21 February 2020

Gorringe Park

Primary 0 034 - Boys Toilet SP

Door Header

Panel 1m² Insulating Board

Good

Condition

Sealed AIB,

spray, textile etc. Amosite 5

Usually

inaccessible 0

Manage & Re-

inspect

21

February 2020

Page 10: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

2. Executive Summary

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 10 of 44

Building

Flo

or

Location L

evel

of

Iden

tifi

cati

on

Item

Exte

nt

Material Assessment

Accessib

ilit

y

Pri

ori

ty

Assessm

en

t

Recommendation N

ext

Insp

ecti

on

Product Type Condition Surface

Treatment Asbestos

Type

To

tal S

co

re

Gorringe Park Primary

0 034 - Boys Toilet SP Toilet Cistern X3

3No. Reinforced Composites

Good Condition

Composite

materials containing asbestos,

plastics, resins etc.

Amosite 3 Usually

inaccessible 0

Manage & Re-inspect

21 Februar

y 2020

Gorringe Park Primary

0 036B - Girls Toilet SP Door Header Panel

1m² Insulating Board Good

Condition Sealed AIB,

spray, textile etc. Amosite 5

Usually inaccessible

0 Manage & Re-inspect

21 February 2020

Gorringe Park

Primary 0 037 - Store SP

Bitumen Adhesive

Below Carpet

2m² Bitumen

Products

Good

Condition

Composite materials containing

asbestos, plastics, resins

etc.

Chrysotile 2 Usually

inaccessible 0

Manage & Re-

inspect

21

February 2020

Gorringe Park Primary

0 041 - Heads Office SP

Bitumen

Adhesive Below Carpet

13m² Bitumen Products

Good Condition

Composite materials

containing asbestos,

plastics, resins

etc.

Chrysotile 2 Usually

inaccessible 1

Manage & Re-inspect

21

February 2020

Gorringe Park Primary

0 042 - Store SP Textured Coating

7m² Textured Coating

Good Condition

Composite materials

containing asbestos,

plastics, resins

etc.

Chrysotile 2 Usually

inaccessible 0

Manage & Re-inspect

21

February 2020

Gorringe Park Primary

0 045 - Hall SP Textured Coating

200m² Textured Coating

Good Condition

Composite materials

containing asbestos,

plastics, resins

etc.

Chrysotile 2 Usually

inaccessible 1

Manage & Re-inspect

21 February 2020

Gorringe Park Primary

0 047 - Reception SP Textured Coating

25m² Textured Coating

Good Condition

Composite

materials containing asbestos,

plastics, resins etc.

Chrysotile 2 Usually

inaccessible 1

Manage & Re-inspect

21 February 2020

Page 11: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

2. Executive Summary

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 11 of 44

Building

Flo

or

Location L

evel

of

Iden

tifi

cati

on

Item

Exte

nt

Material Assessment

Accessib

ilit

y

Pri

ori

ty

Assessm

en

t

Recommendation N

ext

Insp

ecti

on

Product Type Condition Surface

Treatment Asbestos

Type

To

tal S

co

re

Gorringe Park Primary

0 051 - Staff Room P Bitumen Residue To

Floor

30m² Bitumen Products

Good Condition

Composite

materials containing asbestos,

plastics, resins etc.

Chrysotile 2 Usually

inaccessible 1

No Access - Inspection

Required

21 Februar

y 2020

Gorringe Park

Primary 0 055 - Classroom P

Bitumen Residue To

Floor

30m² Bitumen

Products

Good

Condition

Composite materials containing

asbestos, plastics, resins

etc.

Chrysotile 2 Usually

inaccessible 1

No Access - Inspection

Required

21 Februar

y 2020

Gorringe Park

Primary 0 056 - Classroom P

Bitumen

Residue To Floor

30m² Bitumen

Products

Good

Condition

Composite materials containing

asbestos, plastics, resins

etc.

Chrysotile 2 Usually

inaccessible 1

No Access -

Inspection Required

21

February 2020

Gorringe Park Primary

0 057 - Classroom P

Bitumen

Residue To Floor

30m² Bitumen Products

Good Condition

Composite materials

containing asbestos,

plastics, resins etc.

Chrysotile 2 Usually

inaccessible 1

No Access -

Inspection Required

21

February 2020

Gorringe Park Primary

0 059 - Store SP Cement Fire Place

Surround

2m² Cement Products

Good Condition

Sealed AIB, spray, textile etc.

Chrysotile 3 Usually

inaccessible 0

Manage & Re-inspect

21 Februar

y 2020

Gorringe Park Primary

0 059 - Store P Bitumen Residue To Floor

11m² Bitumen Products

Good Condition

Composite materials

containing asbestos,

plastics, resins

etc.

Chrysotile 2 Usually

inaccessible 1

No Access - Inspection Required

21 February 2020

Gorringe Park

Primary 0 061 - Boiler Room SP

Gaskets To

Pipework 1m² Gasket

Good

Condition

Unsealed AIB,

encapsulated spray etc.

Chrysotile 5 Usually

inaccessible 0

Manage & Re-

inspect

21

February 2020

Page 12: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

2. Executive Summary

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 12 of 44

Building

Flo

or

Location L

evel

of

Iden

tifi

cati

on

Item

Exte

nt

Material Assessment

Accessib

ilit

y

Pri

ori

ty

Assessm

en

t

Recommendation N

ext

Insp

ecti

on

Product Type Condition Surface

Treatment Asbestos

Type

To

tal S

co

re

Gorringe Park Primary

0 077 - Corridor SP Floor Tiles 200m² Floor Tiles Good

Condition

Composite

materials containing asbestos,

plastics, resins etc.

Chrysotile 2 Usually

inaccessible 1

Manage & Re-inspect

21 Februar

y 2020

Gorringe Park Primary

0 077 - Corridor SP Panel To Electrical Cupboard

1m² Insulating Board Good

Condition Sealed AIB,

spray, textile etc. Amosite 5

Usually inaccessible

0 Manage & Re-inspect

21 February 2020

Gorringe Park

Primary 0 080 - Corridor P

Bitumen Below

Parquet Flooring

15m² Bitumen

Products

Good

Condition

Composite materials containing

asbestos, plastics, resins

etc.

Chrysotile 2 Usually

inaccessible 1

No Access -

Inspection Required

21

February 2020

Gorringe Park Primary

0 081 - Corridor P

Bitumen

Below Parquet Flooring

15m² Bitumen Products

Good Condition

Composite materials

containing asbestos,

plastics, resins

etc.

Chrysotile 2 Usually

inaccessible 1

No Access -

Inspection Required

21

February 2020

Gorringe Park Primary

0 082 - Corridor P

Bitumen

Below Parquet Flooring

15m² Bitumen Products

Good Condition

Composite materials

containing asbestos,

plastics, resins

etc.

Chrysotile 2 Usually

inaccessible 1

No Access -

Inspection Required

21

February 2020

Gorringe Park Primary

0 085 - Corridor P

Bitumen

Below Parquet Flooring

15m² Bitumen Products

Good Condition

Composite materials

containing asbestos,

plastics, resins

etc.

Chrysotile 2 Usually

inaccessible 1

No Access - Inspection Required

21 February 2020

Gorringe Park

Primary 0 119 - Corridor SP

Door Header

Panel 1m² Insulating Board

Good

Condition

Sealed AIB,

spray, textile etc. Amosite 5

Usually

inaccessible 0

Manage & Re-

inspect

21

February 2020

Page 13: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

2. Executive Summary

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 13 of 44

Building

Flo

or

Location L

evel

of

Iden

tifi

cati

on

Item

Exte

nt

Material Assessment

Accessib

ilit

y

Pri

ori

ty

Assessm

en

t

Recommendation N

ext

Insp

ecti

on

Product Type Condition Surface

Treatment Asbestos

Type

To

tal S

co

re

Gorringe Park Primary

1 063 - Store SP Floor Tiles 3m² Floor Tiles Good

Condition

Composite

materials containing asbestos,

plastics, resins etc.

Chrysotile 2 Usually

inaccessible 0

Manage & Re-inspect

21 Februar

y 2020

Gorringe Park

Primary 1 064 - Store SP Floor Tiles 5m² Floor Tiles

Good

Condition

Composite materials containing

asbestos, plastics, resins

etc.

Chrysotile 2 Usually

inaccessible 0

Manage & Re-

inspect

21 Februar

y 2020

Gorringe Park

Primary 1 065 - Classroom SP Floor Tiles 30m² Floor Tiles

Good

Condition

Composite materials containing

asbestos, plastics, resins

etc.

Chrysotile 2 Usually

inaccessible 1

Manage & Re-

inspect

21

February 2020

Gorringe Park Primary

1 065 - Classroom SP Sink Pad 1No. Bitumen Products

Good Condition

Composite materials

containing asbestos,

plastics, resins etc.

Chrysotile 2 Usually

inaccessible 0

Manage & Re-inspect

21

February 2020

Gorringe Park Primary

1 068 - Classroom P

Bitumen

Below Parquet Flooring

65m² Bitumen Products

Good Condition

Composite materials

containing asbestos,

plastics, resins

etc.

Chrysotile 2 Usually

inaccessible 1

No Access -

Inspection Required

21

February 2020

Gorringe Park Primary

1 073 - Toilet SP Toilet Cistern

1No. Reinforced Composites

Good Condition

Composite materials

containing asbestos,

plastics, resins

etc.

Amosite 3 Usually

inaccessible 0

Manage & Re-inspect

21 February 2020

Page 14: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

2. Executive Summary

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 14 of 44

Building

Flo

or

Location L

evel

of

Iden

tifi

cati

on

Item

Exte

nt

Material Assessment

Accessib

ilit

y

Pri

ori

ty

Assessm

en

t

Recommendation N

ext

Insp

ecti

on

Product Type Condition Surface

Treatment Asbestos

Type

To

tal S

co

re

Gorringe Park Primary

1 077 - Staff Room P

Bitumen Below Parquet

Flooring

47m² Bitumen Products

Good Condition

Composite

materials containing asbestos,

plastics, resins etc.

Chrysotile 2 Usually

inaccessible 1

No Access - Inspection

Required

21 Februar

y 2020

Gorringe Park

Primary

Extern

al External - Gym SP

Damp Proof Course To

Gym

70Lm Bitumen

Products

Good

Condition

Composite materials containing

asbestos, plastics, resins

etc.

Chrysotile 2 Usually

inaccessible 1

Manage & Re-

inspect

21 Februar

y 2020

Page 15: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

3. Reinspection Data Sheets

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 15 of 44

Surveyor Neil De'ath Room/Area 002 - Lounge

Survey Date 21 February 2019 Level of Identification

Presumed

Building Caretakers accommodation Sample No

Floor Ground Floor Item Bitumen Below Parquet Flooring

Item Accessibility Difficult Amount 17m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

No Access - Inspection Required

Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed.

Surveyor Neil De'ath Room/Area 004 - Toilet

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Caretakers accommodation Sample No

Floor Ground Floor Item Floor Tiles

Item Accessibility Difficult Amount 2m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Floor Tiles 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

0 Total Risk Ass’ Score (P.A. + M.A)

2 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

Manage & Re-inspect

Further Information: Visually consistent with sample number GS190810/26. Floor tiles below carpet, previously cross referenced by Noble HSC to sample GS190810/26 in report J14071, found to

contain chrysotile.

Page 16: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

3. Reinspection Data Sheets

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 16 of 44

Surveyor Neil De'ath Room/Area 005 - Lobby

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Caretakers accommodation Sample No

Floor Ground Floor Item Floor Tiles

Item Accessibility Difficult Amount 2m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Floor Tiles 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

0 Total Risk Ass’ Score (P.A. + M.A)

2 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

Manage & Re-inspect

Further Information: Floor tiles below carpet, previously cross referenced by Noble HSC to sample GS190810/26 in report J14071, found to contain chrysotile.

Surveyor Neil De'ath Room/Area 002 - Classroom

Survey Date 21 February 2019 Level of Identification

Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Bitumen Below Parquet Flooring

Item Accessibility Difficult Amount 65m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 3

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

No Access - Inspection Required

Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed

Page 17: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

3. Reinspection Data Sheets

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 17 of 44

Surveyor Neil De'ath Room/Area 002 - Lounge

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Panel To Fireplace

Item Accessibility Difficult Amount 1m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Insulating Board 2 Good Condition 0

Enclosed sprays, lagging and textiles, AIB (encapsulated), asbestos cement and unsealed decorative finishes

1 Amosite 2 5

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

0 Total Risk Ass’ Score (P.A. + M.A)

5 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of

maintenance 0 Recommendation:

Manage & Re-inspect

Further Information: Panel to fireplace, previously sampled by Noble HSC as sample GS190810/02 in report J14071, found to contain amosite.

Surveyor Neil De'ath Room/Area 004 - Electrical Intake

Survey Date 21 February 2019 Level of Identification

Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Flashguards Within Live Electrical Services

Item Accessibility Difficult Amount 1Lm

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Textile Rope & Yarn 1 Good Condition 0 Unsealed AIB or textiles, Gaskets or encapsulated lagging and sprays

2 Chrysotile 1 4

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) =

(1+2+3+4): 0

Total Risk Ass’ Score

(P.A. + M.A) 4 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of

maintenance 0 Recommendation:

No Access - Inspection Required

Further Information: Presumed ACM flashguards within live electrical services, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed.

Page 18: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

3. Reinspection Data Sheets

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 18 of 44

Surveyor Neil De'ath Room/Area 006 - Ict Suite

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Board To Ceiling

Item Accessibility Difficult Amount 9m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Insulating Board 2 Low Damage 1

Enclosed sprays, lagging and textiles, AIB (encapsulated), asbestos cement and unsealed decorative finishes

1 Amosite 2 6

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

0 Total Risk Ass’ Score (P.A. + M.A)

6 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 1

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of

maintenance 0 Recommendation:

Manage & Re-inspect

Further Information: Insulation board to ceiling, previously sampled by Noble HSC as sample GS180810/04 in report J14071, found to contain Amosite.

Surveyor Neil De'ath Room/Area 007 - Store

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Floor Tiles

Item Accessibility Difficult Amount 14m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Floor Tiles 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) =

(1+2+3+4): 1

Total Risk Ass’ Score

(P.A. + M.A) 3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of

maintenance 0 Recommendation:

Manage & Re-inspect

Further Information: Visually consistent with sample number GS180810/03. Floor tiles, previously cross referenced by Noble HSC to sample GS180810/03 in report J14071, found to contain chrysotile.

Floor tiles presumed to be present beneath newly laid carpet tiles, unable to inspect below due to damage limitations.

Page 19: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

3. Reinspection Data Sheets

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 19 of 44

Surveyor Neil De'ath Room/Area 008 - Classroom

Survey Date 21 February 2019 Level of Identification

Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Bitumen Below Parquet Flooring

Item Accessibility Difficult Amount 30m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

No Access - Inspection Required

Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed

Surveyor Neil De'ath Room/Area 009 - Classroom

Survey Date 21 February 2019 Level of Identification

Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Bitumen Below Parquet Flooring

Item Accessibility Difficult Amount 30m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

No Access - Inspection Required

Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed

Page 20: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

3. Reinspection Data Sheets

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 20 of 44

Surveyor Neil De'ath Room/Area 010 - Classroom

Survey Date 21 February 2019 Level of Identification

Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Bitumen Below Parquet Flooring

Item Accessibility Difficult Amount 30m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

No Access - Inspection Required

Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed

Surveyor Neil De'ath Room/Area 016 - Staff Room

Survey Date 21 February 2019 Level of Identification

Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Bitumen Below Parquet Flooring

Item Accessibility Difficult Amount 25m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

No Access - Inspection Required

Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed

Page 21: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

3. Reinspection Data Sheets

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 21 of 44

Surveyor Neil De'ath Room/Area 030 - He

Survey Date 21 February 2019 Level of Identification

Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Bitumen Below Parquet Flooring

Item Accessibility Difficult Amount 30m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

No Access - Inspection Required

Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed

Surveyor Neil De'ath Room/Area 034 - Boys Toilet

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Door Header Panel

Item Accessibility Difficult Amount 1m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Insulating Board 2 Good Condition 0

Enclosed sprays, lagging and textiles, AIB (encapsulated), asbestos cement and unsealed decorative finishes

1 Amosite 2 5

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) =

(1+2+3+4): 0

Total Risk Ass’ Score

(P.A. + M.A) 5 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of

maintenance 0 Recommendation:

Manage & Re-inspect

Further Information: Door Header panel, previously sampled by Noble HSC as sample MP180810/03 in report J14071, found to contain amosite.

Page 22: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

3. Reinspection Data Sheets

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 22 of 44

Surveyor Neil De'ath Room/Area 034 - Boys Toilet

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Toilet Cistern X3

Item Accessibility Difficult Amount 3No.

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Reinforced Composites 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Amosite 2 3

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

0 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

Manage & Re-inspect

Further Information: Toilet Cistern x3, previously sampled by Noble HSC as sample MP180810/04 in report J14071, found to contain amosite.

Surveyor Neil De'ath Room/Area 036B - Girls Toilet

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Door Header Panel

Item Accessibility Difficult Amount 1m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Insulating Board 2 Good Condition 0

Enclosed sprays, lagging and textiles, AIB (encapsulated), asbestos cement and unsealed decorative finishes

1 Amosite 2 5

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) =

(1+2+3+4): 0

Total Risk Ass’ Score

(P.A. + M.A) 5 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of

maintenance 0 Recommendation:

Manage & Re-inspect

Further Information: Visually consistent with sample number MP180810/03 Door Header panel, previously sampled by Noble HSC as sample MP180810/03 in report J14071, found to contain amosite.

Page 23: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

3. Reinspection Data Sheets

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 23 of 44

Surveyor Neil De'ath Room/Area 037 - Store

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Bitumen Adhesive Below Carpet

Item Accessibility Difficult Amount 2m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

0 Total Risk Ass’ Score (P.A. + M.A)

2 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

Manage & Re-inspect

Further Information: Visually consistent with sample number MP180810/05.

Bitumen adhesive below carpet, previously cross referenced by Noble HSC to sample MP180810/05 in report J14071, found to contain chrysotile. Room locked at time of re-inspection presumed to be the same condition.

Surveyor Neil De'ath Room/Area 041 - Heads Office

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Bitumen Adhesive Below Carpet

Item Accessibility Difficult Amount 13m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

Manage & Re-inspect

Further Information: Bitumen adhesive below carpet, previously sampled by Noble HSC as sample MP180810/05 in report J14071, found to contain chrysotile

Page 24: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

3. Reinspection Data Sheets

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 24 of 44

Surveyor Neil De'ath Room/Area 042 - Store

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Textured Coating

Item Accessibility Difficult Amount 7m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Textured Coating 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

0 Total Risk Ass’ Score (P.A. + M.A)

2 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 1

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

Manage & Re-inspect

Further Information: Visually consistent with sample number MP180810/06.

Textured coating, previously cross referenced by Noble HSC to sample MP180810/06 in report J14071, found to contain chrysotile. Presumed to remain in situ beneath plasterboard

Surveyor Neil De'ath Room/Area 045 - Hall

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Textured Coating

Item Accessibility Difficult Amount 200m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Textured Coating 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 3

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

Manage & Re-inspect

Further Information: Visually consistent with sample number MP180810/06.

Textured coating, previously cross referenced by Noble HSC to sample MP180810/06 in report J14071, found to contain chrysotile.

Page 25: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

3. Reinspection Data Sheets

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 25 of 44

Surveyor Neil De'ath Room/Area 047 - Reception

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Textured Coating

Item Accessibility Difficult Amount 25m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Textured Coating 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

Manage & Re-inspect

Further Information: Visually consistent with sample number MP180810/06.

Textured coating, previously cross referenced by Noble HSC to sample MP180810/06 in report J14071, found to contain chrysotile.

Surveyor Neil De'ath Room/Area 051 - Staff Room

Survey Date 21 February 2019 Level of Identification

Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Bitumen Residue To Floor

Item Accessibility Difficult Amount 30m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

No Access - Inspection Required

Further Information: Presumed ACM bitumen residue to floor, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed

Page 26: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

3. Reinspection Data Sheets

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 26 of 44

Surveyor Neil De'ath Room/Area 055 - Classroom

Survey Date 21 February 2019 Level of Identification

Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Bitumen Residue To Floor

Item Accessibility Difficult Amount 30m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

No Access - Inspection Required

Further Information: Presumed ACM bitumen residue to floor, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed

Surveyor Neil De'ath Room/Area 056 - Classroom

Survey Date 21 February 2019 Level of Identification

Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Bitumen Residue To Floor

Item Accessibility Difficult Amount 30m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

No Access - Inspection Required

Further Information: Presumed ACM bitumen residue to floor, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed

Page 27: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

3. Reinspection Data Sheets

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 27 of 44

Surveyor Neil De'ath Room/Area 057 - Classroom

Survey Date 21 February 2019 Level of Identification

Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Bitumen Residue To Floor

Item Accessibility Difficult Amount 30m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

No Access - Inspection Required

Further Information: Presumed ACM bitumen residue to floor, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed

Surveyor Neil De'ath Room/Area 059 - Store

Survey Date 21 February 2019 Level of Identification

Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Bitumen Residue To Floor

Item Accessibility Difficult Amount 11m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

No Access - Inspection Required

Further Information: Presumed ACM bitumen residue to floor, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed.

Unable to gain access at time of re-inspection

Page 28: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

3. Reinspection Data Sheets

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 28 of 44

Surveyor Neil De'ath Room/Area 059 - Store

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Cement Fire Place Surround

Item Accessibility Difficult Amount 2m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Cement Products 1 Good Condition 0

Enclosed sprays, lagging and textiles, AIB (encapsulated), asbestos cement and unsealed decorative finishes

1 Chrysotile 1 3

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

0 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of

maintenance 0 Recommendation:

Manage & Re-inspect

Further Information: Cement fire place surround, previously sampled by Noble HSC as sample GS180810/10 in report J14071, found to contain chrysoti le. Unable to gain access at time of re-inspection

Surveyor Neil De'ath Room/Area 061 - Boiler Room

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Gaskets To Pipework

Item Accessibility Difficult Amount 1m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Gasket 2 Good Condition 0 Unsealed AIB or textiles, Gaskets or encapsulated lagging and sprays

2 Chrysotile 1 5

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) =

(1+2+3+4): 0

Total Risk Ass’ Score

(P.A. + M.A) 5 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of

maintenance 0 Recommendation:

Manage & Re-inspect

Further Information: Visually consistent with sample number GS190810/04. Gaskets to pipework, previously cross referenced by Noble HSC to sample GS190810/04 in report J14071, found to contain chrysotile.

Unable to gain access at time of re-inspection no keys provided on site

Page 29: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

3. Reinspection Data Sheets

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 29 of 44

Surveyor Neil De'ath Room/Area 077 - Corridor

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Floor Tiles

Item Accessibility Difficult Amount 200m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Floor Tiles 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 3

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

Manage & Re-inspect

Further Information: Visually consistent with sample number GS180810/15.

Floor tiles below carpet, previously cross referenced by Noble HSC to sample GS180810/15 in report J14071, found to contain chrysotile.

Surveyor Neil De'ath Room/Area 077 - Corridor

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Panel To Electrical Cupboard

Item Accessibility Difficult Amount 1m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Insulating Board 2 Good Condition 0

Enclosed sprays, lagging and textiles, AIB (encapsulated), asbestos cement and unsealed decorative finishes

1 Amosite 2 5

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) =

(1+2+3+4): 0

Total Risk Ass’ Score

(P.A. + M.A) 5 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of

maintenance 0 Recommendation:

Manage & Re-inspect

Further Information: Panel to electrical cupboard, previously sampled by Noble HSC to sample GS180810/16 in report J14071, found to contain amosite.

Page 30: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

3. Reinspection Data Sheets

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 30 of 44

Surveyor Neil De'ath Room/Area 080 - Corridor

Survey Date 21 February 2019 Level of Identification

Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Bitumen Below Parquet Flooring

Item Accessibility Difficult Amount 15m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

No Access - Inspection Required

Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed

Surveyor Neil De'ath Room/Area 081 - Corridor

Survey Date 21 February 2019 Level of Identification

Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Bitumen Below Parquet Flooring

Item Accessibility Difficult Amount 15m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

No Access - Inspection Required

Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed

Page 31: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

3. Reinspection Data Sheets

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 31 of 44

Surveyor Neil De'ath Room/Area 082 - Corridor

Survey Date 21 February 2019 Level of Identification

Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Bitumen Below Parquet Flooring

Item Accessibility Difficult Amount 15m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

No Access - Inspection Required

Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed

Surveyor Neil De'ath Room/Area 085 - Corridor

Survey Date 21 February 2019 Level of Identification

Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Bitumen Below Parquet Flooring

Item Accessibility Difficult Amount 15m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

No Access - Inspection Required

Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed

Page 32: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

3. Reinspection Data Sheets

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 32 of 44

Surveyor Neil De'ath Room/Area 119 - Corridor

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Gorringe Park Primary Sample No

Floor Ground Floor Item Door Header Panel

Item Accessibility Difficult Amount 1m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Insulating Board 2 Good Condition 0

Enclosed sprays, lagging and textiles, AIB (encapsulated), asbestos cement and unsealed decorative finishes

1 Amosite 2 5

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

0 Total Risk Ass’ Score (P.A. + M.A)

5 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of

maintenance 0 Recommendation:

Manage & Re-inspect

Further Information: Visually consistent with sample number MP180810/03 Door Header panel, previously sampled by Noble HSC as sample MP180810/03 in report J14071, found to contain amosite.

Outside of 0/035A electrical intake

Surveyor Neil De'ath Room/Area 063 - Store

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Gorringe Park Primary Sample No

Floor 1st Floor Item Floor Tiles

Item Accessibility Difficult Amount 3m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Floor Tiles 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

0 Total Risk Ass’ Score (P.A. + M.A)

2 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of

maintenance 0 Recommendation:

Manage & Re-inspect

Further Information: Floor tiles, previously sampled by Noble HSC as sample GS180810/05 in report J14071, found to contain chrysotile.

Page 33: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

3. Reinspection Data Sheets

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 33 of 44

Surveyor Neil De'ath Room/Area 064 - Store

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Gorringe Park Primary Sample No

Floor 1st Floor Item Floor Tiles

Item Accessibility Difficult Amount 5m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Floor Tiles 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

0 Total Risk Ass’ Score (P.A. + M.A)

2 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 1

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

Manage & Re-inspect

Further Information: Visually consistent with sample number GS180810/10

Floor tiles, previously sampled by Noble HSC as sample GS180810/05 in report J14071, found to contain chrysotile.

Surveyor Neil De'ath Room/Area 065 - Classroom

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Gorringe Park Primary Sample No

Floor 1st Floor Item Floor Tiles

Item Accessibility Difficult Amount 30m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Floor Tiles 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

Manage & Re-inspect

Further Information: Visually consistent with sample number GS180810/10

Floor tiles, previously sampled by Noble HSC as sample GS180810/05 in report J14071, found to contain chrysotile.

Page 34: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

3. Reinspection Data Sheets

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 34 of 44

Surveyor Neil De'ath Room/Area 065 - Classroom

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Gorringe Park Primary Sample No

Floor 1st Floor Item Sink Pad

Item Accessibility Difficult Amount 1No.

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

0 Total Risk Ass’ Score (P.A. + M.A)

2 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

Manage & Re-inspect

Further Information: Sink pad, previously sampled by Pennington Choices as sample 015 in report SV54025, found to contain chrysotile.

Surveyor Neil De'ath Room/Area 068 - Classroom

Survey Date 21 February 2019 Level of Identification

Presumed

Building Gorringe Park Primary Sample No

Floor 1st Floor Item Bitumen Below Parquet Flooring

Item Accessibility Difficult Amount 65m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 3

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

No Access - Inspection Required

Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed

Page 35: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

3. Reinspection Data Sheets

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 35 of 44

Surveyor Neil De'ath Room/Area 073 - Toilet

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Gorringe Park Primary Sample No

Floor 1st Floor Item Toilet Cistern

Item Accessibility Difficult Amount 1No.

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Reinforced Composites 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Amosite 2 3

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

0 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

Manage & Re-inspect

Further Information: Visually consistent with sample number MP180810/04. Toilet Cistern, previously cross referenced by Noble HSC to sample MP180810/04 in report J14071, found to contain

amosite.

Surveyor Neil De'ath Room/Area 077 - Staff Room

Survey Date 21 February 2019 Level of Identification

Presumed

Building Gorringe Park Primary Sample No

Floor 1st Floor Item Bitumen Below Parquet Flooring

Item Accessibility Difficult Amount 47m²

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

No Access - Inspection Required

Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed

Page 36: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

3. Reinspection Data Sheets

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 36 of 44

Surveyor Neil De'ath Room/Area External - Gym

Survey Date 21 February 2019 Level of Identification

Strongly Presumed

Building Gorringe Park Primary Sample No

Floor External Item Damp Proof Course To Gym

Item Accessibility Difficult Amount 70Lm

A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):

Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.

0 Chrysotile 1 2

1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):

1 Total Risk Ass’ Score (P.A. + M.A)

3 Risk Coding VERY LOW

2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 3

3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0

4 = Maintenance activity = (L+M)/2 0

L – Type of maintenance 0

M – Frequency of maintenance 0

Recommendation:

Manage & Re-inspect

Further Information: Damp proof course to perimeter of Gym, previously sampled by Noble HSC as sample GS190810/05 in report J14071, found to contain chrysotile.

Page 37: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

4. Additional Bulk Samples

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 37 of 44

No further Bulk samples taken

Page 38: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

Appendix 1 – Definitions & Recommended Guidance

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 38 of 44

Level of Identification

Sample (S) A physical sample was taken on site by the Surveyor and analysed by the laboratory.

Cross reference (X) No sample was taken but the material is visually similar to a sample that has been analysed from

the survey. This is a form of Strong Presumption as defined in HSG264.

Strongly Presumed (SP) No sample was taken but due to the appearance of the material and with the surveyor’s

knowledge and experience the material has been identified as containing asbestos.

Presumed (P) No sample was taken and therefore due to this lack of information the material or item must be

presumed to contain asbestos. This will often be because the item could not be sampled due to excessive height (such

as soffits) or an item could not be inspected (or sampled) as this may have presented a risk to the Surveyor (e.g.

opening up live plant and electrics).

No access areas are also treated as a presumption.

Recommendations

The various recommendations given within this report are explained below:-

Manage & Re-inspect

Where asbestos is left in situ there is a duty to formulate and implement a Management Plan to help prevent accidental

damage and exposure.

The basic requirements of this policy are (from HSG 264):

Keep and maintain an up-to-date record of the location, condition, maintenance and removal of all asbestos-

containing materials

Maintain it in a good state of repair and regularly monitor the condition

Inform anyone who will potentially come into contact with or disturb the material as to its location and condition

Have arrangements and procedures in place, so that work which may disturb the materials complies with the Control

of Asbestos Regulations 2012

Review the plan at regular intervals

Label

A decision should be taken as to whether to label ACMs. The decision will depend on the confidence in the

administration of the asbestos management system and whether communication with workers and contractors coming

to work on site can be effective.

Labelling ACMs should not be solely relied on as a control measure; however it is an effective method of preventing

exposure to building occupants (and, in particular, maintenance workers). If, for any reason, management procedures

fail, it may act as an effective last barrier to uncontrolled damage to the ACM.

It may not always be prudent or practical to label all installations of asbestos; for example high level items such as roof

sheets, flue cowls and soffits or items such as gaskets to pipe flanges, textured coating and floor tiles.

Encapsulate

When this recommendation has been given, the ACM is raw and requires encapsulating with a suitable sealant or the

existing sealant or covering has deteriorated and the installation requires either a complete or partial re-encapsulation.

Page 39: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

Appendix 1 – Definitions & Recommended Guidance

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 39 of 44

We recommend that sealing or painting of insulating board, insulation or spray coatings should be undertaken by a

licensed contractor and is likely to be subject to a 14 day notification to the HSE, (as per the Control of Asbestos

Regulations 2012).

Repair

The material has sustained damage to some area or areas and requires attention to make good the material so that it

can be managed safely. This will often involve some element of decontamination if debris is associated with the

damage.

Remove

If an item is recommended for removal it has either sustained damage and is posing an increased risk in its current

condition; or due to its location it is considered high risk as it could easily be disturbed in the future. Materials

recommended for removal will be given one of the following recommendations:-

Removal by Licensed Contractor. This will include removal of AIB, Insulation, and Spray Coatings and is likely to be

subject to a 14 day notification to the HSE, (as per the Control of Asbestos Regulations 2012).

Removal by Approved Contractor. This will include removal of lower risk materials such as Asbestos Cement,

Bitumen Products, Reinforced Composites, and Floor Tiles etc. Some such works may be considered Notifiable Non-

Licensed Works.

The Control of Asbestos Regulations 2012 does not necessarily require such removal works to be undertaken by a

licensed contractor. However it is good practice, and we would strongly recommended that all removal works are

undertaken by a licensed contractor.

Restrict Access

Materials have been identified that are in a damaged condition often with associated debris that can be easily

disturbed. As such access to the area should be prevented to all persons until such a time when the area has been

deemed safe for reoccupation. This will usually be once removal works have been completed.

No Access – Inspection Required

Access to the given location was either not possible at all or only limited access was possible. In both instances there

is the potential for unidentified asbestos being present and as such the area must be treated as containing asbestos

until full access is possible.

Arrangements should be made at the earliest opportunity to revisit locations where access was not possible or access

was limited in order that such areas can be inspected fully.

Items and materials that are presumed to contain asbestos will also be given the recommendation of ‘No Access –

Inspection required’. In these instances the item or material should be treated as containing asbestos until

arrangements can be made to access such items or materials in order to carry out an inspection or sample to confirm

or otherwise the presence of asbestos.

No Recommendation Required

Asbestos has not been identified and as such no further action is required.

Recommended Guidance

To comply with and ensure that the requirements of section 2 & 3 of the Health and Safety at Work Act (as amended)

1974, the Management of Health and Safety at Work Regulations 1999, the Control of Asbestos Regulations 2012 and

the Control of Substances Hazardous to Health 2002 are met, the following recommendations should be implemented:

Page 40: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

Appendix 1 – Definitions & Recommended Guidance

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 40 of 44

Undertake suitable and sufficient Risk Assessments of identified ACMs against normal occupation and maintenance

operations, in compliance with Regulations 3 of the Management of Health & Safety at Work Regulations 1999 and

Regulation 6 of the Control of Asbestos Regulations 2012.

The findings of the survey be brought to the attention of those persons who are likely to come in contact with asbestos, in

compliance with Section 2 and 3 of the Health and Safety at Work Act (as amended) 1974 and Regulation 9 of the Control

of Asbestos Regulations 2012.

Implement an Asbestos Management Policy, Plan and review process in compliance Regulation 4 of the Control of

Asbestos Regulations 2012.

During the course of the survey it may not have been possible to access all areas of the site. Details of areas requiring

further access is identified within the Data Sheets and Executive Summary of this report. In accordance with HSG 264,

asbestos is presumed to be present within these areas and should be treated accordingly until further inspection and

analysis of building fabric and services proves otherwise.

It is recommended that air monitoring is carried out within any areas where ACMs have been identified in order to assess

airborne fibre levels within adjacent occupied areas in relation to the clearance indicator, as documented by HSG 248 The

Analyst Guide.

Where asbestos debris or asbestos in poor condition has been found it is recommended that access is restricted to these

areas in accordance with Regulation 11 of the Control of Asbestos Regulations 2012 and that air monitoring is carried out

within adjacent areas in order to assess airborne fibre levels.

All identified asbestos to be appropriately identified and subject to Risk Assessment, management, and re-inspection.

Site specific recommendations in respect to the location and condition of asbestos materials identified during the

course of this inspection are detailed in the Survey Data Sheets and Asbestos register. In considering the management

of asbestos materials identified to date, these recommendations should be referred to and complied with.

It is recommended that work on, or removal of, both licensed and non licensed ACMs is undertaken by a licensed

asbestos removal contractor so that the Duty Holder / Client can have confidence that the contractor has provided the

correct level of training and has the experience and knowledge necessary to deal with these products safely.

It is a requirement of CAR 2012 that further intrusive investigations and sampling be carried out where any refurbishment,

maintenance, or similar activity is planned that may expose asbestos materials. This should be a refurbishment/demolition

survey as documented by HSG 264.

The findings of this report should not be solely relied upon in obtaining costs for proposed asbestos abatement work. Any

proposed abatement/removal of the asbestos should be undertaken against a detailed specification.

Page 41: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

Appendix 2 – Material & Priority Assessment Algorithms

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 41 of 44

Where ACMs have been identified or presumed to be present a Material Assessment Algorithm has been calculated as detailed in HSG 264 and reproduced in line with the table overleaf. The Material Assessment is an assessment of the condition of the ACM, or the presumed ACM, and the likelihood of it releasing fibres in the event of it being disturbed in some way. This Material Assessment will give a good initial guide to the priority for management as it will identify the materials which will most readily release airborne fibres if disturbed. However, there are other factors to take into account when prioritising action. These are considered in the Priority Assessment which is described later. For each of the four variables given by the table a score is allocated. The four scores are added together to give a Material Assessment score of between 2 and 12. HIGH RISK 10-12 Materials with scores of 10 or more should be regarded as high risk with a significant potential to release fibres if disturbed; MEDIUM RISK 7- 9 Those materials with a score between 7 and 9 are regarded as medium risk to release fibres. LOW RISK 5-6 Materials with a score between 5 and 6 are low risk to release fibres. VERY LOW RISK 4 or less Scores of 4 or less are very low risk.

Section Sample

Variable Score Examples of Score

A Product type (or debris from product).

1 Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi rigid paint or decorative finishes, asbestos cement,

etc).

2 Asbestos insulating board, mill boards, other low-density insulation boards, asbestos textiles, gaskets, ropes and woven textiles, asbestos

paper and felt.

3 Thermal insulation (e.g.: pipe and boiler lagging), sprayed asbestos,

loose asbestos, asbestos mattresses and packing.

B Extent of damage/

deterioration.

0 Good condition: no visible damage.

1 Low damage: a few scratches or surface marks; broken edges on boards, tiles, etc.

2

Medium damage: significant breakage of materials or several small

areas where material has been damaged revealing loose asbestos fibres.

3 High damage or delamination of materials, sprays and thermal insulation. Visible asbestos debris.

C Surface Treatment

0 Composite materials containing asbestos: reinforced plastics, resins,

vinyl tiles.

1 Enclosed sprays and lagging, AIB (with exposed face painted or

encapsulated), unsealed cement sheets, etc.

2 Unsealed AIB, or encapsulated lagging and sprays.

3 Unsealed lagging and sprays.

D Asbestos type

1 Chrysotile.

2 Amphibole asbestos excluding Crocidolite.

3 Crocidolite.

Material Assessment Score = A + B + C + D

Page 42: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

Appendix 2 – Material & Priority Assessment Algorithms

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 42 of 44

The Material Assessment identifies the high risk materials, that is, those which will most readily release airborne fibres if disturbed. It does not automatically follow that those materials assigned the highest score in the Material Assessment will be the materials that should be given priority for remedial action. Management priority must be determined by carrying out a Risk Assessment which will also take into account the likely maintenance activity; occupant activity; likelihood of disturbance; and human exposure potential. The Priority Assessment Algorithm looks at the likelihood of someone disturbing the ACM. Please note Priority Assessments have not been undertaken as part of this survey. A legal requirement to carry out a Risk Assessment for all work activities exists under the Management of Health and Safety at Work Regulations 1999. The requirement to assess the risk posed by asbestos is further enforced by the Control of Asbestos Regulations 2012. These regulations require that asbestos present in the workplace must not present a hazard to health The risks from asbestos should be assessed and managed for all identified or presumed ACMs. The Risk Assessment or priority rating will establish the likelihood of people being exposed to the hazard and identify the measures to be taken that will either eliminate the hazard or adequately control it. The Priority Assessment Score is calculated on the average scores for each of the four human exposure factors given by the table on the following page. It is the responsibility of the Duty Holder to complete the Priority Risk Assessment, and ensure it remains up to date and accurate.

Section Factor Score Examples of Score

Normal Occupant Activity Score = E

E Main Type of Activity

0 Rare Disturbance activity (e.g. Store Room)

1 Low Disturbance Activity (e.g. Office)

2 Periodic Disturbance (May contact ACMs)

3 High Level of disturbance (e.g. panel on door)

Likelihood of Disturbance Score = Average of F + G + H

F Location

0 Outdoors

1 Large Rooms or well ventilated Areas

2 Rooms up to 100sqm

3 Confined Spaces

G Accessibility

0 Usually Inaccessible or unlikely to be disturbed

1 Occasional Disturbance

2 Easily Disturbed

3 Routinely Disturbed

H Extent

0 Very Small Amounts

1 <10sqm or <10lm

2 >10sqm to <50sqm or >10lm to <50lm

3 <50sqm or >50lm

Human Exposure Potential Score = Average of I + J + K

I No of Occupants

0 None

1 1-3

2 4-10

3 >10

J Frequency of Use

0 Infrequent

1 Monthly

2 Weekly

3 Daily

K Average Time in Use

0 <1 Hour

1 >1 hour and <3 hours

2 >3 hours to <6 hours

3 >6 Hours

Maintenance Activity Score = Average of L + M

L Type of Activity

0 Minor disturbance e.g. possible contact

1 Low disturbance e.g. removing light bulb

2 Medium Disturbance

3 High levels of disturbance

Page 43: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

Appendix 2 – Material & Priority Assessment Algorithms

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 43 of 44

M

Frequency of

Maintenance

0 ACM unlikely to be disturbed

1 1 per Year

2 >1 per year

3 >1 per Month

Risk Assessment The Risk Assessment Priority Algorithm is calculated by adding the Material Assessment Score obtained during the survey to the Priority Assessment Score.

HIGH RISK - 18 POINTS OR MORE The potential hazard arising from this category warrants urgent action. Immediate plans should be made for the removal/containment of the ACM. If delay in remedial action is likely to occur the affected area should initially be sealed-off and appropriate warning signs posted. MEDIUM RISK - 14-17 POINTS This category indicates that deterioration in any of the contributory factors may result in fibre release. Therefore all asbestos should be contained/sealed/encapsulated. LOW RISK - 9-13 Points This category indicates the need for regular monitoring. Although the current risk of fibre release is low, this material may suffer deterioration through age/local accidental damage. VERY LOW RISK 8 or less Similarly this category requires regular monitoring. Although the current risk of fibre release is low, this material may suffer deterioration through age/local accidental damage.

Page 44: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

Appendix 3 – Survey Drawings

Version 08, May 2018 Life Environmental Services Issue No. 1

Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 44 of 44

Page 45: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

UP

UP

UP

UP

Biomass

UP

Boiler

0/109

Entrance Lobby

12.85 m²

E30

E1

E2

E3

E5E4

E6

E7

E9

E8

E11

E12

E17

E16

E15

E14E13

E21

E20

E19

E18 E22

E24

E23

E25

E26

E27E28

E29

E32E31

E33

E35

E34

E36

E37

E38

0/048

Lobby

4.66 m²

0/108

Store

5.27 m²

0/110

Corridor

13.52 m²

0/107

Store

8.53 m²

0/106

Kitchen

6.20 m²

0/105

Photocopy Room

7.36 m²

0/103

Corridor

2.74 m²

0/102

Classroom

46.51 m²

0/015

Deputy Head's Office

16.41 m²

0/104

Head's Office

25.36 m²

0/101

Classroom Year 4

47.04 m²

0/100

Classroom Year 4

47.17 m²

0/097

Toilet (Boys)

20.58 m²

0/098

Toilet (Girls)

20.86 m²

0/099

Lobby

3.53 m²

0/004A

Lobby

4.50 m²

0/075

Corridor

7.45 m²

0/003

Store

6.56 m²

0/001

Store

12.00 m²

0/078

Cleaning Cpd

2.57 m²

0/062

Kitchen

39.77 m²

0/060A

Store

2.11 m²

0/060

One To One Room

13.96 m²

0/093

One To One Room

10.23 m²

0/058

Toilet (Accessible)

6.79 m²

0/094

Corridor

8.47 m²

0/054

Corridor

8.44 m²

0/095

Office

10.75 m²

0/053

Toilet (Girls)

13.89 m²

0/052

Toilet (Boys)

13.60 m²

0/096

Cleaning Cpd

2.78 m²

0/111

Corridor

7.19 m²

0/112

Store

0.51 m²

0/114

Store

1.27 m²

0/113

Toilet (Pupils)

14.97 m²

0/116

Wood Pellet Store

5.57 m²

0/117

Plant Room

29.35 m²

0/017

Classroom Year 1

59.38 m²

0/018

Classroom Year 1

59.07 m²

0/019

Classroom Year 1

59.26 m²

0/118

Gas Cpd

1.55 m²

0/120

Toilet (Pupils)

10.41 m²

0/036

Corridor

15.93 m²

0/035A

Elect Intake

1.39 m²

0/035

Caretaker's Office

9.00 m²

0/036B

Cleaning Store

3.13 m²

0/038A

Store

1.41 m²

0/023B

Elect Intake

10.50 m²

0/121

Corridor

2.99 m²

0/039

Toilet (Staff/Female)

8.45 m²

0/039B

Toilet (Staff/Male)

1.38 m²

0/039A

Lobby

0.68 m²

0/022

Corridor

11.46 m²

0/022A

Toilet (Pupils)

13.20 m²

0/122

Store

5.11 m²

0/020

Store

13.30 m²

0/023

After School Club

46.47 m²

0/024

After School Club

47.09 m²

0/025

After School Club

47.22 m²

0/026

Group Room

16.99 m²

0/128

Toilet (Pupils)

15.27 m²

0/127

Corridor

18.80 m²

0/123

Hall

129.04 m²

0/033

Classroom Year 2

46.31 m²

0/032

Classroom Year 2

46.52 m²

0/031

Classroom Year 2

46.63 m²

0/090

Corridor

15.35 m²

0/124

Store

8.38 m²

0/091

Store

10.76 m²

0/126

Cloaks

17.33 m²

0/129

Store

1.09 m²

0/125

Office

5.63 m²

0/130

Reception Classroom

200.03 m²

0/132

Corridor

21.39 m²

0/131

Store

6.04 m²

0/134

Office

14.55 m²

0/133

Riser

0.72 m²

0/138

Store

3.98 m²

0/139

Riser

0.62 m²

0/136

Store

0.59 m²

0/137

Toilet (Pupils)

18.98 m²

0/135

Toilet (Accessible)

4.97 m²

0/140

Nursery

119.44 m²0/002

0/005

0/006

0/007

0/008 0/009 0/0100/

016

0/0300/034

0/036B

0/041

0/042

0/045

0/047

0/049

0/0510/0550/0560/057

0/059

0/061

0/0760/076A

0/004

0/077

0/080

0/08

1

0/08

2

0/085

0/086

0/115

OldSheds

Ground & External Floor PlanBlock A

GS190810/02

P

P

GS190810/26

GS180810/03

GS180810/04

SV54025/10

As GS180810/03

P P P

0/029 Boiler Room -Demolished

P

As GS190810/04

P

MP1

8081

0/03

MP1

8081

0/04

As S

V540

25/0

5

As M

P180

810/

03

As M

P180

810/

03

0/119

As M

P180

810/

05

0/037

MP1

8081

0/04

As MP180810/06As MP180810/06

As MP180810/06

P

PPP

PGS180810/10

As GS190810/04

As GS180810/15

As GS180810/03

P

GS180810/16As GS180810/15

PP

P

P

MP180810/01

MP180810/06

RoomDemolished

Removed

GS190810/05

Ext

Drawing Not to Scale Drawing should not be viewed in isolation. Please refer to Report Asbestos Register.

Drawn By:

Life Environmental Services Ltd.

4 Ducketts WharfSouth Street

Bishop’s Stortford CM23 3AR

Telephone: 0844 335 1281

Email: [email protected]

www.lifeenvironmental.co.uk

Registered in England No. 3053057

Revision No.: 2.5 Nov 2017

001

Job No.:

Key

- Location Number

- Asbestos Present

- No Access

(Please refer to register)

- Limited Access to Specified Level

- No Access to Specified LevelWithin Area

Within Area

- Limited Access

SP

S0001

S0001

X0001

P

S0001

- Outside Scope of Survey

- Asbestos Removed

- Positive Sample

- Cross Referenced Positive Sample

- Strongly Presumed Asbestos

- Presumed Asbestos

- Sample - No Asbestos Detected

Date:

Page:

SURVEY PLAN - Standard

Gorringe Park Primary

B-82297

WJ

01/03/2019

1 of 3

X0001- Cross Referenced Sample - No Asbestos Detected

Page 46: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

UP

UP

UP

UP

UP

1/094

Shower Room

3.52 m²

1/093

Toilet (Staff)

2.51 m²

1/092

Stairwell

9.02 m²

1/076

Store

6.22 m²

1/075

Group Room

18.36 m²

1/095

Store

8.17 m²

1/036

Stairwell

4.84 m²

1/096

Store

1.81 m²

1/097

Stairwell

3.68 m²

1/071

Meeting Room

16.15 m²

1/072

Toilet (Staff)

4.62 m²

1/084

Corridor

2.41 m²

1/098

Stairwell

4.63 m²

1/069

Deputy Head's Office

18.52 m²

1/070

Store

9.55 m²

1/085A

Store

16.33 m²

1/099

Group Room

6.55 m²

1/066

Group Room

10.48 m²

1/067

Toilet (Pupils)

8.48 m²

1/063

1/064

1/065

1/068

1/073

1/07

6A

1/077

Lofts

First Floor PlanBlock A

Second Floor PlanBlock A

GS180810/10

As GS180810/10

As GS180810/10

SV54025/15

P

As MP180810/04

P

P

Drawing Not to Scale Drawing should not be viewed in isolation. Please refer to Report Asbestos Register.

Drawn By:

Life Environmental Services Ltd.

4 Ducketts WharfSouth Street

Bishop’s Stortford CM23 3AR

Telephone: 0844 335 1281

Email: [email protected]

www.lifeenvironmental.co.uk

Registered in England No. 3053057

Revision No.: 2.5 Nov 2017

001

Job No.:

Key

- Location Number

- Asbestos Present

- No Access

(Please refer to register)

- Limited Access to Specified Level

- No Access to Specified LevelWithin Area

Within Area

- Limited Access

SP

S0001

S0001

X0001

P

S0001

- Outside Scope of Survey

- Asbestos Removed

- Positive Sample

- Cross Referenced Positive Sample

- Strongly Presumed Asbestos

- Presumed Asbestos

- Sample - No Asbestos Detected

Date:

Page:

SURVEY PLAN - Standard

Gorringe Park Primary

B-82297

WJ

01/03/2019

2 of 3

X0001- Cross Referenced Sample - No Asbestos Detected

Page 47: Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life Environmental Services Issue No. 1 Reinspection Survey & PA B-82297 - Gorringe Park

UP

UP

0/001

Store

10.51 m²

E4c E2c

E3c

E1c

E1bE3b

E2b

E4b

0/003

Kitchen

12.14 m²

0/006

Store

1.71 m²

0/000

Store

2.26 m²

0/001

Stairwell

3.24 m²

0/000

Lobby

1.71 m²

1/003

Bedroom

8.55 m²

1/002

Bedroom

7.54 m²

1/005

Bedroom

14.24 m²

1/001

Stairwell

6.60 m²

1/000

Bathroom

3.44 m²

0/002

0/004

0/005

First Floor PlanBlock B

Ground Floor PlanBlock B

Ground Floor PlanBlock C

P

As GS190810/02

SV54025/05

Drawing Not to Scale Drawing should not be viewed in isolation. Please refer to Report Asbestos Register.

Drawn By:

Life Environmental Services Ltd.

4 Ducketts WharfSouth Street

Bishop’s Stortford CM23 3AR

Telephone: 0844 335 1281

Email: [email protected]

www.lifeenvironmental.co.uk

Registered in England No. 3053057

Revision No.: 2.5 Nov 2017

001

Job No.:

Key

- Location Number

- Asbestos Present

- No Access

(Please refer to register)

- Limited Access to Specified Level

- No Access to Specified LevelWithin Area

Within Area

- Limited Access

SP

S0001

S0001

X0001

P

S0001

- Outside Scope of Survey

- Asbestos Removed

- Positive Sample

- Cross Referenced Positive Sample

- Strongly Presumed Asbestos

- Presumed Asbestos

- Sample - No Asbestos Detected

Date:

Page:

SURVEY PLAN - Standard

Gorringe Park Primary

B-82297

WJ

01/03/2019

3 of 3

X0001- Cross Referenced Sample - No Asbestos Detected