Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life...
Transcript of Asbestos Reinspection Report · Life Environmental - Survey Report Guide Version 08, May 2018 Life...
Asbestos
Reinspection Report (with Priority Assessments)
Gorringe Park Primary
Sandy Lane,
Mitcham, Surrey,
CR4 2YA
56886 / 23151
Project Number: B-82297
Issue Date: 1st
March 2019
Issue No: 1
Client Contact:
Life Environmental Services Ltd Contact: Andy Sweeney
London Borough of Merton Merton Civic Centre London Road Morden Surrey SM4 5DX
4 Duckett’s Wharf South Street Bishop’s Stortford Hertfordshire CM23 3AR
Tel: 02085453382 Tel: 01279 503117 Fax: Fax: 01279 503162
Life Environmental - Survey Report Guide
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 2 of 44
This guide explains the Section content of the survey report. Failure to use the information provided in the report correctly may result in incorrect information or assumptions being obtained. Section 1.0 Executive Summary The Executive Summary contains details of the scope and extent of the works. The reader must ensure that the scope covers the required areas and that any variations do not impact on any proposed works or management of the site. All areas of no access should be considered as containing asbestos until proven otherwise. Recommended Actions provides a summary of all identified and presumed asbestos containing materials (ACMs). ACMs are listed by recommendation with those requiring urgent attention listed first. The Asbestos Register presents ACMs by building, floor & location. It provides a detailed list of all locations included within the survey where positive samples have been taken or items are presumed to contain asbestos. Items physically sampled will show the asbestos type within the analysis column. Items cross referenced (strong presumption) have their asbestos type determined by the sample result of materials of similar appearance and use that have been sampled elsewhere on site. These will show the analysis proceeded by X. Strongly Presumed samples are items that the surveyor was unable to sample but the materials are similar in appearance and use to known asbestos-containing materials and hence they are confirmed as containing asbestos. Presumed items are those that the surveyor was unable to sample or inspect adequately to confirm the presence of asbestos, as such there is a potential for asbestos being present and the item is presumed to contain asbestos. A Material Assessment algorithm has been completed for all positive samples. It should be noted that to enable an accurate Priority Assessment to be undertaken this requires a detailed knowledge of the property. The responsibility for this lies with the dutyholder, although Life Environmental can assist with the provision of information or generic assessments where agreed. Recommendations within this report are based on the condition of the asbestos and the Material Assessment. Prior to carrying out these recommendations consideration should be given to the Priority Assessment Algorithm. Section 2.0 Introduction The Introduction provides a general overview of the purpose, aims and type of survey undertaken. It also presents Project particulars and Quality Assurance. Section 3.0 Survey Findings – Survey Reinspection Data Sheets Survey Data Sheets contains detailed information on all suspect items with a photographic record of each item. Section 4.0 – Survey Findings – Certificate & Schedule of Additional Bulk Samples This section provides analysis information and results of any additional samples taken. Appendix 1 - Definitions & Recommended Guidance These contain a general guidance relating to Samples, Assessments and Recommendations and a detailed Risk Assessment explanation. Appendix 2 - Material & Priority Assessment algorithms These contain a general guidance relating to detailed Risk Assessment explanation. Appendix 3 - Survey Drawings All locations will be given a unique reference number which corresponds to the location detailed within the Asbestos Register. The drawings highlight areas containing positive information and areas of no access. In the case of planned works, a check should always be made of adjacent areas.
1. Introduction
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 3 of 44
1. Introduction
a. Purpose & Aim of Survey
b. Quality Assurance
2. Executive Summary
a. Revisions
b. Recommended Actions c. Asbestos Register
3. Reinspection Data Sheets
4. Additional Bulk Samples
Appendices:
Appendix 1 - Definitions & Recommended Guidance
Appendix 2 - Material & Priority Assessment algorithms
Appendix 3 - Survey Drawings
1. Introduction
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 4 of 44
Life Environmental Services Ltd received an order of confirmation to undertake a Reinspection Survey from London Borough of Merton. This order has been accepted on the basis of the original Quotation and our terms and conditions of business. This reinspection is subject to copyright and protected by copyright law. The brief for these works was to carry out a reinspection of the Asbestos Containing Materials (ACMs) within the Gorringe Park Primary. The reinspection is based upon the previous report ref B-70564 and B-76460 This reinspection considered any damage and disturbance to items identified in the above survey. Every effort has been made to access any areas that were previously not accessible in the original survey. Where such locations have still not been accessed, asbestos should be presumed to be present within these areas. Each section of this report focuses on one or two aspects; no section should be taken and read as a stand-alone document. It is imperative that each section is read in conjunction with each other. This reinspection report forms an addendum to the original survey. The original survey report should be referred to for the following items of information:
Information on the original survey methodology/caveats
Original laboratory bulk analysis certificate of analysed samples
Original drawings
It should be noted that this report is not intended as a Scope of Works for asbestos removal and that a detailed technical document could be provided upon request. If any maintenance works are to be undertaken within the areas not accessed then a further survey and assessment should be carried out prior to these works.
Client Details: London Borough of Merton
Date(s) of Survey: 21-February-2019
Surveyor(s): Lead Surveyor(s): Neil De’ath
Report Prepared by: Stephanie Goody 1st March 2019
Quality Control by: Neil De’ath 1st March 2019
Life Environmental Project Manager:
Andy Sweeney
2. Executive Summary
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 5 of 44
a. Revisions
The following table summarises the items removed between the most recent re-inspection and it’s predecessor.
No items have been removed since the last inspection.
b. Recommended Actions Detailed below is guidance on actions to be taken to prevent potential exposure to ACMs. There follows a summary of all reinspected asbestos items that require further action in order that they can be managed safely Please note that if additional samples or suspect items have been identified during the reinspection these will be detailed in Section 3 (Reinspection Data Sheets) of this report only and will not be detailed below or within any part of Section 2 of the report. Please note the colour coding is based on the recommendation only and is not determined by the Material Assessment scores, these are explained within the original asbestos survey report. Some lower risk items may be recommended for removal based on its location or usage rather than the score only. Please contact Life Environmental Services Ltd for advice in dealing with any asbestos in poor, unsealed or damaged condition or for assistance in developing your management plan and scheduling reinspections.
Manage and Re-inspect
ACMs have been identified which are in good condition. A management policy and plan need to be implemented to manage these materials safely.
Building Floor Location Number
and Name Item Material
Level of Identification
Risk Assessment
Caretakers
accommodation 0 004 - Toilet Floor Tiles Floor Tiles SP 2
Caretakers accommodation
0 005 - Lobby Floor Tiles Floor Tiles SP 2
Gorringe Park Primary
0 002 - Lounge Panel To Fireplace
Insulating Board
SP 5
Gorringe Park Primary
0 006 - Ict Suite Board To Ceiling
Insulating Board
SP 6
Gorringe Park Primary
0 007 - Store Floor Tiles Floor Tiles SP 2
Gorringe Park Primary
0 034 - Boys Toilet Door Header Panel
Insulating Board
SP 5
Gorringe Park Primary
0 034 - Boys Toilet Toilet Cistern X3
Reinforced Composites
SP 3
Gorringe Park Primary
0 036B - Girls Toilet Door Header Panel
Insulating Board
SP 5
Gorringe Park
Primary 0 037 - Store
Bitumen Adhesive
Below Carpet
Bitumen
Products SP 2
Gorringe Park Primary
0 041 - Heads Office
Bitumen
Adhesive Below Carpet
Bitumen Products
SP 2
Gorringe Park Primary
0 042 - Store Textured Coating
Textured Coating
SP 2
Gorringe Park Primary
0 045 - Hall Textured Coating
Textured Coating
SP 2
2. Executive Summary
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 6 of 44
Manage and Re-inspect
ACMs have been identified which are in good condition. A management policy and plan need to be implemented to manage these materials safely.
Building Floor Location Number
and Name Item Material
Level of Identification
Risk Assessment
Gorringe Park
Primary 0 047 - Reception
Textured
Coating
Textured
Coating SP 2
Gorringe Park
Primary 0 059 - Store
Cement Fire
Place Surround
Cement
Products SP 3
Gorringe Park
Primary 0 061 - Boiler Room
Gaskets To
Pipework Gasket SP 5
Gorringe Park Primary
0 077 - Corridor Floor Tiles Floor Tiles SP 2
Gorringe Park Primary
0 077 - Corridor
Panel To
Electrical Cupboard
Insulating Board
SP 5
Gorringe Park Primary
0 119 - Corridor Door Header Panel
Insulating Board
SP 5
Gorringe Park Primary
1 063 - Store Floor Tiles Floor Tiles SP 2
Gorringe Park Primary
1 064 - Store Floor Tiles Floor Tiles SP 2
Gorringe Park Primary
1 065 - Classroom Floor Tiles Floor Tiles SP 2
Gorringe Park Primary
1 065 - Classroom Sink Pad Bitumen Products
SP 2
Gorringe Park Primary
1 073 - Toilet Toilet Cistern
Reinforced Composites
SP 3
Gorringe Park
Primary
Extern
al External - Gym
Damp Proof Course To
Gym
Bitumen
Products SP 2
Presumed Items
The following items have been presumed to contain asbestos where it was not possible to access the item in order to sample. These items must be treated as containing asbestos until access can be arranged in order to inspect or sample to confirm or refute the presence of asbestos.
Building Floor Location Number
and Name Item Material
Level of Identification
Risk Assessment
Caretakers accommodation
0 002 - Lounge
Bitumen Below Parquet
Flooring
Bitumen Products
P 2
Gorringe Park
Primary 0 002 - Classroom
Bitumen Below
Parquet Flooring
Bitumen
Products P 2
Gorringe Park Primary
0 004 - Electrical Intake
Flashguards Within Live Electrical
Services
Textile Rope & Yarn
P 4
Gorringe Park
Primary 0 008 - Classroom
Bitumen Below
Parquet Flooring
Bitumen
Products P 2
Gorringe Park Primary
0 009 - Classroom
Bitumen
Below Parquet Flooring
Bitumen Products
P 2
Gorringe Park Primary
0 010 - Classroom Bitumen Below
Bitumen Products
P 2
2. Executive Summary
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 7 of 44
Presumed Items
The following items have been presumed to contain asbestos where it was not possible to access the item in order to sample. These items must be treated as containing asbestos until access can be arranged in order to inspect or sample to confirm or refute the presence of asbestos.
Building Floor Location Number
and Name Item Material
Level of Identification
Risk Assessment
Parquet Flooring
Gorringe Park
Primary 0 016 - Staff Room
Bitumen Below
Parquet Flooring
Bitumen
Products P 2
Gorringe Park Primary
0 030 - He
Bitumen
Below Parquet Flooring
Bitumen Products
P 2
Gorringe Park Primary
0 051 - Staff Room Bitumen Residue To Floor
Bitumen Products
P 2
Gorringe Park Primary
0 055 - Classroom Bitumen Residue To
Floor
Bitumen Products
P 2
Gorringe Park Primary
0 056 - Classroom Bitumen Residue To
Floor
Bitumen Products
P 2
Gorringe Park
Primary 0 057 - Classroom
Bitumen Residue To
Floor
Bitumen
Products P 2
Gorringe Park
Primary 0 059 - Store
Bitumen Residue To
Floor
Bitumen
Products P 2
Gorringe Park Primary
0 080 - Corridor
Bitumen
Below Parquet Flooring
Bitumen Products
P 2
Gorringe Park Primary
0 081 - Corridor
Bitumen Below Parquet
Flooring
Bitumen Products
P 2
Gorringe Park
Primary 0 082 - Corridor
Bitumen Below
Parquet Flooring
Bitumen
Products P 2
Gorringe Park Primary
0 085 - Corridor
Bitumen
Below Parquet Flooring
Bitumen Products
P 2
Gorringe Park Primary
1 068 - Classroom
Bitumen Below Parquet
Flooring
Bitumen Products
P 2
Gorringe Park Primary
1 077 - Staff Room
Bitumen
Below Parquet Flooring
Bitumen Products
P 2
All locations were accessible at the time of this survey.
2. Executive Summary
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 8 of 44
c. Asbestos Register
Building
Flo
or
Location L
evel
of
Iden
tifi
cati
on
Item
Exte
nt
Material Assessment
Accessib
ilit
y
Pri
ori
ty
Assessm
en
t
Recommendation N
ext
Insp
ecti
on
Product Type Condition Surface
Treatment Asbestos
Type
To
tal S
co
re
Caretakers accommodation
0 002 - Lounge P
Bitumen Below Parquet
Flooring
17m² Bitumen Products
Good Condition
Composite
materials containing asbestos,
plastics, resins etc.
Chrysotile 2 Usually
inaccessible 1
No Access - Inspection Required
21 February 2020
Caretakers accommodation
0 004 - Toilet SP Floor Tiles 2m² Floor Tiles Good
Condition
Composite
materials containing asbestos,
plastics, resins etc.
Chrysotile 2 Usually
inaccessible 0
Manage & Re-inspect
21 February 2020
Caretakers accommodatio
n
0 005 - Lobby SP Floor Tiles 2m² Floor Tiles Good
Condition
Composite
materials containing asbestos,
plastics, resins etc.
Chrysotile 2 Usually
inaccessible 0
Manage & Re-inspect
21 Februar
y 2020
Gorringe Park Primary
0 002 - Lounge SP Panel To Fireplace
1m² Insulating Board Good
Condition Sealed AIB,
spray, textile etc. Amosite 5
Usually inaccessible
0 Manage & Re-inspect
21 February 2020
Gorringe Park
Primary 0 002 - Classroom P
Bitumen Below
Parquet Flooring
65m² Bitumen
Products
Good
Condition
Composite materials containing
asbestos, plastics, resins
etc.
Chrysotile 2 Usually
inaccessible 1
No Access -
Inspection Required
21
February 2020
Gorringe Park
Primary 0
004 - Electrical
Intake P
Flashguards Within Live
Electrical Services
1Lm Textile Rope &
Yarn
Good
Condition
Unsealed AIB, encapsulated
spray etc.
Chrysotile 4 Usually
inaccessible 0
No Access - Inspection
Required
21 Februar
y 2020
Gorringe Park Primary
0 006 - Ict Suite SP Board To Ceiling
9m² Insulating Board Low
Damage Sealed AIB,
spray, textile etc. Amosite 6
Usually inaccessible
0 Manage & Re-inspect
21
February 2020
2. Executive Summary
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 9 of 44
Building
Flo
or
Location L
evel
of
Iden
tifi
cati
on
Item
Exte
nt
Material Assessment
Accessib
ilit
y
Pri
ori
ty
Assessm
en
t
Recommendation N
ext
Insp
ecti
on
Product Type Condition Surface
Treatment Asbestos
Type
To
tal S
co
re
Gorringe Park Primary
0 007 - Store SP Floor Tiles 14m² Floor Tiles Good
Condition
Composite
materials containing asbestos,
plastics, resins etc.
Chrysotile 2 Usually
inaccessible 1
Manage & Re-inspect
21 Februar
y 2020
Gorringe Park
Primary 0 008 - Classroom P
Bitumen Below
Parquet Flooring
30m² Bitumen
Products
Good
Condition
Composite materials containing
asbestos, plastics, resins
etc.
Chrysotile 2 Usually
inaccessible 1
No Access - Inspection
Required
21 Februar
y 2020
Gorringe Park
Primary 0 009 - Classroom P
Bitumen Below
Parquet Flooring
30m² Bitumen
Products
Good
Condition
Composite materials containing
asbestos, plastics, resins
etc.
Chrysotile 2 Usually
inaccessible 1
No Access -
Inspection Required
21
February 2020
Gorringe Park Primary
0 010 - Classroom P
Bitumen
Below Parquet Flooring
30m² Bitumen Products
Good Condition
Composite materials
containing asbestos,
plastics, resins etc.
Chrysotile 2 Usually
inaccessible 1
No Access -
Inspection Required
21
February 2020
Gorringe Park Primary
0 016 - Staff Room P
Bitumen
Below Parquet Flooring
25m² Bitumen Products
Good Condition
Composite materials
containing asbestos,
plastics, resins
etc.
Chrysotile 2 Usually
inaccessible 1
No Access -
Inspection Required
21
February 2020
Gorringe Park Primary
0 030 - He P
Bitumen
Below Parquet Flooring
30m² Bitumen Products
Good Condition
Composite materials
containing asbestos,
plastics, resins
etc.
Chrysotile 2 Usually
inaccessible 1
No Access - Inspection Required
21 February 2020
Gorringe Park
Primary 0 034 - Boys Toilet SP
Door Header
Panel 1m² Insulating Board
Good
Condition
Sealed AIB,
spray, textile etc. Amosite 5
Usually
inaccessible 0
Manage & Re-
inspect
21
February 2020
2. Executive Summary
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 10 of 44
Building
Flo
or
Location L
evel
of
Iden
tifi
cati
on
Item
Exte
nt
Material Assessment
Accessib
ilit
y
Pri
ori
ty
Assessm
en
t
Recommendation N
ext
Insp
ecti
on
Product Type Condition Surface
Treatment Asbestos
Type
To
tal S
co
re
Gorringe Park Primary
0 034 - Boys Toilet SP Toilet Cistern X3
3No. Reinforced Composites
Good Condition
Composite
materials containing asbestos,
plastics, resins etc.
Amosite 3 Usually
inaccessible 0
Manage & Re-inspect
21 Februar
y 2020
Gorringe Park Primary
0 036B - Girls Toilet SP Door Header Panel
1m² Insulating Board Good
Condition Sealed AIB,
spray, textile etc. Amosite 5
Usually inaccessible
0 Manage & Re-inspect
21 February 2020
Gorringe Park
Primary 0 037 - Store SP
Bitumen Adhesive
Below Carpet
2m² Bitumen
Products
Good
Condition
Composite materials containing
asbestos, plastics, resins
etc.
Chrysotile 2 Usually
inaccessible 0
Manage & Re-
inspect
21
February 2020
Gorringe Park Primary
0 041 - Heads Office SP
Bitumen
Adhesive Below Carpet
13m² Bitumen Products
Good Condition
Composite materials
containing asbestos,
plastics, resins
etc.
Chrysotile 2 Usually
inaccessible 1
Manage & Re-inspect
21
February 2020
Gorringe Park Primary
0 042 - Store SP Textured Coating
7m² Textured Coating
Good Condition
Composite materials
containing asbestos,
plastics, resins
etc.
Chrysotile 2 Usually
inaccessible 0
Manage & Re-inspect
21
February 2020
Gorringe Park Primary
0 045 - Hall SP Textured Coating
200m² Textured Coating
Good Condition
Composite materials
containing asbestos,
plastics, resins
etc.
Chrysotile 2 Usually
inaccessible 1
Manage & Re-inspect
21 February 2020
Gorringe Park Primary
0 047 - Reception SP Textured Coating
25m² Textured Coating
Good Condition
Composite
materials containing asbestos,
plastics, resins etc.
Chrysotile 2 Usually
inaccessible 1
Manage & Re-inspect
21 February 2020
2. Executive Summary
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 11 of 44
Building
Flo
or
Location L
evel
of
Iden
tifi
cati
on
Item
Exte
nt
Material Assessment
Accessib
ilit
y
Pri
ori
ty
Assessm
en
t
Recommendation N
ext
Insp
ecti
on
Product Type Condition Surface
Treatment Asbestos
Type
To
tal S
co
re
Gorringe Park Primary
0 051 - Staff Room P Bitumen Residue To
Floor
30m² Bitumen Products
Good Condition
Composite
materials containing asbestos,
plastics, resins etc.
Chrysotile 2 Usually
inaccessible 1
No Access - Inspection
Required
21 Februar
y 2020
Gorringe Park
Primary 0 055 - Classroom P
Bitumen Residue To
Floor
30m² Bitumen
Products
Good
Condition
Composite materials containing
asbestos, plastics, resins
etc.
Chrysotile 2 Usually
inaccessible 1
No Access - Inspection
Required
21 Februar
y 2020
Gorringe Park
Primary 0 056 - Classroom P
Bitumen
Residue To Floor
30m² Bitumen
Products
Good
Condition
Composite materials containing
asbestos, plastics, resins
etc.
Chrysotile 2 Usually
inaccessible 1
No Access -
Inspection Required
21
February 2020
Gorringe Park Primary
0 057 - Classroom P
Bitumen
Residue To Floor
30m² Bitumen Products
Good Condition
Composite materials
containing asbestos,
plastics, resins etc.
Chrysotile 2 Usually
inaccessible 1
No Access -
Inspection Required
21
February 2020
Gorringe Park Primary
0 059 - Store SP Cement Fire Place
Surround
2m² Cement Products
Good Condition
Sealed AIB, spray, textile etc.
Chrysotile 3 Usually
inaccessible 0
Manage & Re-inspect
21 Februar
y 2020
Gorringe Park Primary
0 059 - Store P Bitumen Residue To Floor
11m² Bitumen Products
Good Condition
Composite materials
containing asbestos,
plastics, resins
etc.
Chrysotile 2 Usually
inaccessible 1
No Access - Inspection Required
21 February 2020
Gorringe Park
Primary 0 061 - Boiler Room SP
Gaskets To
Pipework 1m² Gasket
Good
Condition
Unsealed AIB,
encapsulated spray etc.
Chrysotile 5 Usually
inaccessible 0
Manage & Re-
inspect
21
February 2020
2. Executive Summary
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 12 of 44
Building
Flo
or
Location L
evel
of
Iden
tifi
cati
on
Item
Exte
nt
Material Assessment
Accessib
ilit
y
Pri
ori
ty
Assessm
en
t
Recommendation N
ext
Insp
ecti
on
Product Type Condition Surface
Treatment Asbestos
Type
To
tal S
co
re
Gorringe Park Primary
0 077 - Corridor SP Floor Tiles 200m² Floor Tiles Good
Condition
Composite
materials containing asbestos,
plastics, resins etc.
Chrysotile 2 Usually
inaccessible 1
Manage & Re-inspect
21 Februar
y 2020
Gorringe Park Primary
0 077 - Corridor SP Panel To Electrical Cupboard
1m² Insulating Board Good
Condition Sealed AIB,
spray, textile etc. Amosite 5
Usually inaccessible
0 Manage & Re-inspect
21 February 2020
Gorringe Park
Primary 0 080 - Corridor P
Bitumen Below
Parquet Flooring
15m² Bitumen
Products
Good
Condition
Composite materials containing
asbestos, plastics, resins
etc.
Chrysotile 2 Usually
inaccessible 1
No Access -
Inspection Required
21
February 2020
Gorringe Park Primary
0 081 - Corridor P
Bitumen
Below Parquet Flooring
15m² Bitumen Products
Good Condition
Composite materials
containing asbestos,
plastics, resins
etc.
Chrysotile 2 Usually
inaccessible 1
No Access -
Inspection Required
21
February 2020
Gorringe Park Primary
0 082 - Corridor P
Bitumen
Below Parquet Flooring
15m² Bitumen Products
Good Condition
Composite materials
containing asbestos,
plastics, resins
etc.
Chrysotile 2 Usually
inaccessible 1
No Access -
Inspection Required
21
February 2020
Gorringe Park Primary
0 085 - Corridor P
Bitumen
Below Parquet Flooring
15m² Bitumen Products
Good Condition
Composite materials
containing asbestos,
plastics, resins
etc.
Chrysotile 2 Usually
inaccessible 1
No Access - Inspection Required
21 February 2020
Gorringe Park
Primary 0 119 - Corridor SP
Door Header
Panel 1m² Insulating Board
Good
Condition
Sealed AIB,
spray, textile etc. Amosite 5
Usually
inaccessible 0
Manage & Re-
inspect
21
February 2020
2. Executive Summary
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 13 of 44
Building
Flo
or
Location L
evel
of
Iden
tifi
cati
on
Item
Exte
nt
Material Assessment
Accessib
ilit
y
Pri
ori
ty
Assessm
en
t
Recommendation N
ext
Insp
ecti
on
Product Type Condition Surface
Treatment Asbestos
Type
To
tal S
co
re
Gorringe Park Primary
1 063 - Store SP Floor Tiles 3m² Floor Tiles Good
Condition
Composite
materials containing asbestos,
plastics, resins etc.
Chrysotile 2 Usually
inaccessible 0
Manage & Re-inspect
21 Februar
y 2020
Gorringe Park
Primary 1 064 - Store SP Floor Tiles 5m² Floor Tiles
Good
Condition
Composite materials containing
asbestos, plastics, resins
etc.
Chrysotile 2 Usually
inaccessible 0
Manage & Re-
inspect
21 Februar
y 2020
Gorringe Park
Primary 1 065 - Classroom SP Floor Tiles 30m² Floor Tiles
Good
Condition
Composite materials containing
asbestos, plastics, resins
etc.
Chrysotile 2 Usually
inaccessible 1
Manage & Re-
inspect
21
February 2020
Gorringe Park Primary
1 065 - Classroom SP Sink Pad 1No. Bitumen Products
Good Condition
Composite materials
containing asbestos,
plastics, resins etc.
Chrysotile 2 Usually
inaccessible 0
Manage & Re-inspect
21
February 2020
Gorringe Park Primary
1 068 - Classroom P
Bitumen
Below Parquet Flooring
65m² Bitumen Products
Good Condition
Composite materials
containing asbestos,
plastics, resins
etc.
Chrysotile 2 Usually
inaccessible 1
No Access -
Inspection Required
21
February 2020
Gorringe Park Primary
1 073 - Toilet SP Toilet Cistern
1No. Reinforced Composites
Good Condition
Composite materials
containing asbestos,
plastics, resins
etc.
Amosite 3 Usually
inaccessible 0
Manage & Re-inspect
21 February 2020
2. Executive Summary
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 14 of 44
Building
Flo
or
Location L
evel
of
Iden
tifi
cati
on
Item
Exte
nt
Material Assessment
Accessib
ilit
y
Pri
ori
ty
Assessm
en
t
Recommendation N
ext
Insp
ecti
on
Product Type Condition Surface
Treatment Asbestos
Type
To
tal S
co
re
Gorringe Park Primary
1 077 - Staff Room P
Bitumen Below Parquet
Flooring
47m² Bitumen Products
Good Condition
Composite
materials containing asbestos,
plastics, resins etc.
Chrysotile 2 Usually
inaccessible 1
No Access - Inspection
Required
21 Februar
y 2020
Gorringe Park
Primary
Extern
al External - Gym SP
Damp Proof Course To
Gym
70Lm Bitumen
Products
Good
Condition
Composite materials containing
asbestos, plastics, resins
etc.
Chrysotile 2 Usually
inaccessible 1
Manage & Re-
inspect
21 Februar
y 2020
3. Reinspection Data Sheets
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 15 of 44
Surveyor Neil De'ath Room/Area 002 - Lounge
Survey Date 21 February 2019 Level of Identification
Presumed
Building Caretakers accommodation Sample No
Floor Ground Floor Item Bitumen Below Parquet Flooring
Item Accessibility Difficult Amount 17m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
No Access - Inspection Required
Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed.
Surveyor Neil De'ath Room/Area 004 - Toilet
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Caretakers accommodation Sample No
Floor Ground Floor Item Floor Tiles
Item Accessibility Difficult Amount 2m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Floor Tiles 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
0 Total Risk Ass’ Score (P.A. + M.A)
2 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
Manage & Re-inspect
Further Information: Visually consistent with sample number GS190810/26. Floor tiles below carpet, previously cross referenced by Noble HSC to sample GS190810/26 in report J14071, found to
contain chrysotile.
3. Reinspection Data Sheets
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 16 of 44
Surveyor Neil De'ath Room/Area 005 - Lobby
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Caretakers accommodation Sample No
Floor Ground Floor Item Floor Tiles
Item Accessibility Difficult Amount 2m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Floor Tiles 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
0 Total Risk Ass’ Score (P.A. + M.A)
2 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
Manage & Re-inspect
Further Information: Floor tiles below carpet, previously cross referenced by Noble HSC to sample GS190810/26 in report J14071, found to contain chrysotile.
Surveyor Neil De'ath Room/Area 002 - Classroom
Survey Date 21 February 2019 Level of Identification
Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Bitumen Below Parquet Flooring
Item Accessibility Difficult Amount 65m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 3
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
No Access - Inspection Required
Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed
3. Reinspection Data Sheets
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 17 of 44
Surveyor Neil De'ath Room/Area 002 - Lounge
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Panel To Fireplace
Item Accessibility Difficult Amount 1m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Insulating Board 2 Good Condition 0
Enclosed sprays, lagging and textiles, AIB (encapsulated), asbestos cement and unsealed decorative finishes
1 Amosite 2 5
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
0 Total Risk Ass’ Score (P.A. + M.A)
5 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of
maintenance 0 Recommendation:
Manage & Re-inspect
Further Information: Panel to fireplace, previously sampled by Noble HSC as sample GS190810/02 in report J14071, found to contain amosite.
Surveyor Neil De'ath Room/Area 004 - Electrical Intake
Survey Date 21 February 2019 Level of Identification
Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Flashguards Within Live Electrical Services
Item Accessibility Difficult Amount 1Lm
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Textile Rope & Yarn 1 Good Condition 0 Unsealed AIB or textiles, Gaskets or encapsulated lagging and sprays
2 Chrysotile 1 4
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) =
(1+2+3+4): 0
Total Risk Ass’ Score
(P.A. + M.A) 4 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of
maintenance 0 Recommendation:
No Access - Inspection Required
Further Information: Presumed ACM flashguards within live electrical services, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed.
3. Reinspection Data Sheets
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 18 of 44
Surveyor Neil De'ath Room/Area 006 - Ict Suite
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Board To Ceiling
Item Accessibility Difficult Amount 9m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Insulating Board 2 Low Damage 1
Enclosed sprays, lagging and textiles, AIB (encapsulated), asbestos cement and unsealed decorative finishes
1 Amosite 2 6
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
0 Total Risk Ass’ Score (P.A. + M.A)
6 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 1
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of
maintenance 0 Recommendation:
Manage & Re-inspect
Further Information: Insulation board to ceiling, previously sampled by Noble HSC as sample GS180810/04 in report J14071, found to contain Amosite.
Surveyor Neil De'ath Room/Area 007 - Store
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Floor Tiles
Item Accessibility Difficult Amount 14m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Floor Tiles 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) =
(1+2+3+4): 1
Total Risk Ass’ Score
(P.A. + M.A) 3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of
maintenance 0 Recommendation:
Manage & Re-inspect
Further Information: Visually consistent with sample number GS180810/03. Floor tiles, previously cross referenced by Noble HSC to sample GS180810/03 in report J14071, found to contain chrysotile.
Floor tiles presumed to be present beneath newly laid carpet tiles, unable to inspect below due to damage limitations.
3. Reinspection Data Sheets
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 19 of 44
Surveyor Neil De'ath Room/Area 008 - Classroom
Survey Date 21 February 2019 Level of Identification
Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Bitumen Below Parquet Flooring
Item Accessibility Difficult Amount 30m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
No Access - Inspection Required
Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed
Surveyor Neil De'ath Room/Area 009 - Classroom
Survey Date 21 February 2019 Level of Identification
Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Bitumen Below Parquet Flooring
Item Accessibility Difficult Amount 30m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
No Access - Inspection Required
Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed
3. Reinspection Data Sheets
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 20 of 44
Surveyor Neil De'ath Room/Area 010 - Classroom
Survey Date 21 February 2019 Level of Identification
Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Bitumen Below Parquet Flooring
Item Accessibility Difficult Amount 30m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
No Access - Inspection Required
Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed
Surveyor Neil De'ath Room/Area 016 - Staff Room
Survey Date 21 February 2019 Level of Identification
Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Bitumen Below Parquet Flooring
Item Accessibility Difficult Amount 25m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
No Access - Inspection Required
Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed
3. Reinspection Data Sheets
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 21 of 44
Surveyor Neil De'ath Room/Area 030 - He
Survey Date 21 February 2019 Level of Identification
Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Bitumen Below Parquet Flooring
Item Accessibility Difficult Amount 30m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
No Access - Inspection Required
Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed
Surveyor Neil De'ath Room/Area 034 - Boys Toilet
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Door Header Panel
Item Accessibility Difficult Amount 1m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Insulating Board 2 Good Condition 0
Enclosed sprays, lagging and textiles, AIB (encapsulated), asbestos cement and unsealed decorative finishes
1 Amosite 2 5
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) =
(1+2+3+4): 0
Total Risk Ass’ Score
(P.A. + M.A) 5 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of
maintenance 0 Recommendation:
Manage & Re-inspect
Further Information: Door Header panel, previously sampled by Noble HSC as sample MP180810/03 in report J14071, found to contain amosite.
3. Reinspection Data Sheets
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 22 of 44
Surveyor Neil De'ath Room/Area 034 - Boys Toilet
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Toilet Cistern X3
Item Accessibility Difficult Amount 3No.
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Reinforced Composites 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Amosite 2 3
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
0 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
Manage & Re-inspect
Further Information: Toilet Cistern x3, previously sampled by Noble HSC as sample MP180810/04 in report J14071, found to contain amosite.
Surveyor Neil De'ath Room/Area 036B - Girls Toilet
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Door Header Panel
Item Accessibility Difficult Amount 1m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Insulating Board 2 Good Condition 0
Enclosed sprays, lagging and textiles, AIB (encapsulated), asbestos cement and unsealed decorative finishes
1 Amosite 2 5
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) =
(1+2+3+4): 0
Total Risk Ass’ Score
(P.A. + M.A) 5 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of
maintenance 0 Recommendation:
Manage & Re-inspect
Further Information: Visually consistent with sample number MP180810/03 Door Header panel, previously sampled by Noble HSC as sample MP180810/03 in report J14071, found to contain amosite.
3. Reinspection Data Sheets
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 23 of 44
Surveyor Neil De'ath Room/Area 037 - Store
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Bitumen Adhesive Below Carpet
Item Accessibility Difficult Amount 2m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
0 Total Risk Ass’ Score (P.A. + M.A)
2 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
Manage & Re-inspect
Further Information: Visually consistent with sample number MP180810/05.
Bitumen adhesive below carpet, previously cross referenced by Noble HSC to sample MP180810/05 in report J14071, found to contain chrysotile. Room locked at time of re-inspection presumed to be the same condition.
Surveyor Neil De'ath Room/Area 041 - Heads Office
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Bitumen Adhesive Below Carpet
Item Accessibility Difficult Amount 13m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
Manage & Re-inspect
Further Information: Bitumen adhesive below carpet, previously sampled by Noble HSC as sample MP180810/05 in report J14071, found to contain chrysotile
3. Reinspection Data Sheets
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 24 of 44
Surveyor Neil De'ath Room/Area 042 - Store
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Textured Coating
Item Accessibility Difficult Amount 7m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Textured Coating 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
0 Total Risk Ass’ Score (P.A. + M.A)
2 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 1
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
Manage & Re-inspect
Further Information: Visually consistent with sample number MP180810/06.
Textured coating, previously cross referenced by Noble HSC to sample MP180810/06 in report J14071, found to contain chrysotile. Presumed to remain in situ beneath plasterboard
Surveyor Neil De'ath Room/Area 045 - Hall
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Textured Coating
Item Accessibility Difficult Amount 200m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Textured Coating 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 3
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
Manage & Re-inspect
Further Information: Visually consistent with sample number MP180810/06.
Textured coating, previously cross referenced by Noble HSC to sample MP180810/06 in report J14071, found to contain chrysotile.
3. Reinspection Data Sheets
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 25 of 44
Surveyor Neil De'ath Room/Area 047 - Reception
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Textured Coating
Item Accessibility Difficult Amount 25m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Textured Coating 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
Manage & Re-inspect
Further Information: Visually consistent with sample number MP180810/06.
Textured coating, previously cross referenced by Noble HSC to sample MP180810/06 in report J14071, found to contain chrysotile.
Surveyor Neil De'ath Room/Area 051 - Staff Room
Survey Date 21 February 2019 Level of Identification
Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Bitumen Residue To Floor
Item Accessibility Difficult Amount 30m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
No Access - Inspection Required
Further Information: Presumed ACM bitumen residue to floor, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed
3. Reinspection Data Sheets
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 26 of 44
Surveyor Neil De'ath Room/Area 055 - Classroom
Survey Date 21 February 2019 Level of Identification
Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Bitumen Residue To Floor
Item Accessibility Difficult Amount 30m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
No Access - Inspection Required
Further Information: Presumed ACM bitumen residue to floor, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed
Surveyor Neil De'ath Room/Area 056 - Classroom
Survey Date 21 February 2019 Level of Identification
Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Bitumen Residue To Floor
Item Accessibility Difficult Amount 30m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
No Access - Inspection Required
Further Information: Presumed ACM bitumen residue to floor, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed
3. Reinspection Data Sheets
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 27 of 44
Surveyor Neil De'ath Room/Area 057 - Classroom
Survey Date 21 February 2019 Level of Identification
Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Bitumen Residue To Floor
Item Accessibility Difficult Amount 30m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
No Access - Inspection Required
Further Information: Presumed ACM bitumen residue to floor, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed
Surveyor Neil De'ath Room/Area 059 - Store
Survey Date 21 February 2019 Level of Identification
Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Bitumen Residue To Floor
Item Accessibility Difficult Amount 11m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
No Access - Inspection Required
Further Information: Presumed ACM bitumen residue to floor, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed.
Unable to gain access at time of re-inspection
3. Reinspection Data Sheets
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 28 of 44
Surveyor Neil De'ath Room/Area 059 - Store
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Cement Fire Place Surround
Item Accessibility Difficult Amount 2m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Cement Products 1 Good Condition 0
Enclosed sprays, lagging and textiles, AIB (encapsulated), asbestos cement and unsealed decorative finishes
1 Chrysotile 1 3
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
0 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of
maintenance 0 Recommendation:
Manage & Re-inspect
Further Information: Cement fire place surround, previously sampled by Noble HSC as sample GS180810/10 in report J14071, found to contain chrysoti le. Unable to gain access at time of re-inspection
Surveyor Neil De'ath Room/Area 061 - Boiler Room
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Gaskets To Pipework
Item Accessibility Difficult Amount 1m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Gasket 2 Good Condition 0 Unsealed AIB or textiles, Gaskets or encapsulated lagging and sprays
2 Chrysotile 1 5
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) =
(1+2+3+4): 0
Total Risk Ass’ Score
(P.A. + M.A) 5 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of
maintenance 0 Recommendation:
Manage & Re-inspect
Further Information: Visually consistent with sample number GS190810/04. Gaskets to pipework, previously cross referenced by Noble HSC to sample GS190810/04 in report J14071, found to contain chrysotile.
Unable to gain access at time of re-inspection no keys provided on site
3. Reinspection Data Sheets
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 29 of 44
Surveyor Neil De'ath Room/Area 077 - Corridor
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Floor Tiles
Item Accessibility Difficult Amount 200m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Floor Tiles 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 3
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
Manage & Re-inspect
Further Information: Visually consistent with sample number GS180810/15.
Floor tiles below carpet, previously cross referenced by Noble HSC to sample GS180810/15 in report J14071, found to contain chrysotile.
Surveyor Neil De'ath Room/Area 077 - Corridor
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Panel To Electrical Cupboard
Item Accessibility Difficult Amount 1m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Insulating Board 2 Good Condition 0
Enclosed sprays, lagging and textiles, AIB (encapsulated), asbestos cement and unsealed decorative finishes
1 Amosite 2 5
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) =
(1+2+3+4): 0
Total Risk Ass’ Score
(P.A. + M.A) 5 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of
maintenance 0 Recommendation:
Manage & Re-inspect
Further Information: Panel to electrical cupboard, previously sampled by Noble HSC to sample GS180810/16 in report J14071, found to contain amosite.
3. Reinspection Data Sheets
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 30 of 44
Surveyor Neil De'ath Room/Area 080 - Corridor
Survey Date 21 February 2019 Level of Identification
Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Bitumen Below Parquet Flooring
Item Accessibility Difficult Amount 15m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
No Access - Inspection Required
Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed
Surveyor Neil De'ath Room/Area 081 - Corridor
Survey Date 21 February 2019 Level of Identification
Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Bitumen Below Parquet Flooring
Item Accessibility Difficult Amount 15m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
No Access - Inspection Required
Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed
3. Reinspection Data Sheets
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 31 of 44
Surveyor Neil De'ath Room/Area 082 - Corridor
Survey Date 21 February 2019 Level of Identification
Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Bitumen Below Parquet Flooring
Item Accessibility Difficult Amount 15m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
No Access - Inspection Required
Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed
Surveyor Neil De'ath Room/Area 085 - Corridor
Survey Date 21 February 2019 Level of Identification
Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Bitumen Below Parquet Flooring
Item Accessibility Difficult Amount 15m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
No Access - Inspection Required
Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed
3. Reinspection Data Sheets
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 32 of 44
Surveyor Neil De'ath Room/Area 119 - Corridor
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Gorringe Park Primary Sample No
Floor Ground Floor Item Door Header Panel
Item Accessibility Difficult Amount 1m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Insulating Board 2 Good Condition 0
Enclosed sprays, lagging and textiles, AIB (encapsulated), asbestos cement and unsealed decorative finishes
1 Amosite 2 5
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
0 Total Risk Ass’ Score (P.A. + M.A)
5 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of
maintenance 0 Recommendation:
Manage & Re-inspect
Further Information: Visually consistent with sample number MP180810/03 Door Header panel, previously sampled by Noble HSC as sample MP180810/03 in report J14071, found to contain amosite.
Outside of 0/035A electrical intake
Surveyor Neil De'ath Room/Area 063 - Store
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Gorringe Park Primary Sample No
Floor 1st Floor Item Floor Tiles
Item Accessibility Difficult Amount 3m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Floor Tiles 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
0 Total Risk Ass’ Score (P.A. + M.A)
2 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of
maintenance 0 Recommendation:
Manage & Re-inspect
Further Information: Floor tiles, previously sampled by Noble HSC as sample GS180810/05 in report J14071, found to contain chrysotile.
3. Reinspection Data Sheets
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 33 of 44
Surveyor Neil De'ath Room/Area 064 - Store
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Gorringe Park Primary Sample No
Floor 1st Floor Item Floor Tiles
Item Accessibility Difficult Amount 5m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Floor Tiles 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
0 Total Risk Ass’ Score (P.A. + M.A)
2 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 1
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
Manage & Re-inspect
Further Information: Visually consistent with sample number GS180810/10
Floor tiles, previously sampled by Noble HSC as sample GS180810/05 in report J14071, found to contain chrysotile.
Surveyor Neil De'ath Room/Area 065 - Classroom
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Gorringe Park Primary Sample No
Floor 1st Floor Item Floor Tiles
Item Accessibility Difficult Amount 30m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Floor Tiles 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
Manage & Re-inspect
Further Information: Visually consistent with sample number GS180810/10
Floor tiles, previously sampled by Noble HSC as sample GS180810/05 in report J14071, found to contain chrysotile.
3. Reinspection Data Sheets
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 34 of 44
Surveyor Neil De'ath Room/Area 065 - Classroom
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Gorringe Park Primary Sample No
Floor 1st Floor Item Sink Pad
Item Accessibility Difficult Amount 1No.
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
0 Total Risk Ass’ Score (P.A. + M.A)
2 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
Manage & Re-inspect
Further Information: Sink pad, previously sampled by Pennington Choices as sample 015 in report SV54025, found to contain chrysotile.
Surveyor Neil De'ath Room/Area 068 - Classroom
Survey Date 21 February 2019 Level of Identification
Presumed
Building Gorringe Park Primary Sample No
Floor 1st Floor Item Bitumen Below Parquet Flooring
Item Accessibility Difficult Amount 65m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 3
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
No Access - Inspection Required
Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed
3. Reinspection Data Sheets
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 35 of 44
Surveyor Neil De'ath Room/Area 073 - Toilet
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Gorringe Park Primary Sample No
Floor 1st Floor Item Toilet Cistern
Item Accessibility Difficult Amount 1No.
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Reinforced Composites 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Amosite 2 3
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
0 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 0 F – Location 0 G – Accessibility 0 H – Extent 0
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
Manage & Re-inspect
Further Information: Visually consistent with sample number MP180810/04. Toilet Cistern, previously cross referenced by Noble HSC to sample MP180810/04 in report J14071, found to contain
amosite.
Surveyor Neil De'ath Room/Area 077 - Staff Room
Survey Date 21 February 2019 Level of Identification
Presumed
Building Gorringe Park Primary Sample No
Floor 1st Floor Item Bitumen Below Parquet Flooring
Item Accessibility Difficult Amount 47m²
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 2
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
No Access - Inspection Required
Further Information: Presumed ACM bitumen below parquet flooring, previously presumed by Noble HSC to contain chrysotile in report J14071 until accessed
3. Reinspection Data Sheets
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 36 of 44
Surveyor Neil De'ath Room/Area External - Gym
Survey Date 21 February 2019 Level of Identification
Strongly Presumed
Building Gorringe Park Primary Sample No
Floor External Item Damp Proof Course To Gym
Item Accessibility Difficult Amount 70Lm
A - Product Type: B - Extent of Damage: C – Surface Treatment D – Asbestos Type Material Ass (M.A) (A+B+C+D):
Bitumen Products 1 Good Condition 0 Composite materials; reinforced plastics, resins, vinyl tiles, sealed decorative finishes, etc.
0 Chrysotile 1 2
1 = Normal Occupant Activity = (E) 0 E – Main type of activity 0 Total Priority Score (P.A.) = (1+2+3+4):
1 Total Risk Ass’ Score (P.A. + M.A)
3 Risk Coding VERY LOW
2 = Disturbance = (F+G+H)/3 1 F – Location 0 G – Accessibility 0 H – Extent 3
3 = Exposure potential = (I+J+K)/3 0 I – Number of occupants 0 J – Frequency of use 0 K – Average time in use 0
4 = Maintenance activity = (L+M)/2 0
L – Type of maintenance 0
M – Frequency of maintenance 0
Recommendation:
Manage & Re-inspect
Further Information: Damp proof course to perimeter of Gym, previously sampled by Noble HSC as sample GS190810/05 in report J14071, found to contain chrysotile.
4. Additional Bulk Samples
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 37 of 44
No further Bulk samples taken
Appendix 1 – Definitions & Recommended Guidance
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 38 of 44
Level of Identification
Sample (S) A physical sample was taken on site by the Surveyor and analysed by the laboratory.
Cross reference (X) No sample was taken but the material is visually similar to a sample that has been analysed from
the survey. This is a form of Strong Presumption as defined in HSG264.
Strongly Presumed (SP) No sample was taken but due to the appearance of the material and with the surveyor’s
knowledge and experience the material has been identified as containing asbestos.
Presumed (P) No sample was taken and therefore due to this lack of information the material or item must be
presumed to contain asbestos. This will often be because the item could not be sampled due to excessive height (such
as soffits) or an item could not be inspected (or sampled) as this may have presented a risk to the Surveyor (e.g.
opening up live plant and electrics).
No access areas are also treated as a presumption.
Recommendations
The various recommendations given within this report are explained below:-
Manage & Re-inspect
Where asbestos is left in situ there is a duty to formulate and implement a Management Plan to help prevent accidental
damage and exposure.
The basic requirements of this policy are (from HSG 264):
Keep and maintain an up-to-date record of the location, condition, maintenance and removal of all asbestos-
containing materials
Maintain it in a good state of repair and regularly monitor the condition
Inform anyone who will potentially come into contact with or disturb the material as to its location and condition
Have arrangements and procedures in place, so that work which may disturb the materials complies with the Control
of Asbestos Regulations 2012
Review the plan at regular intervals
Label
A decision should be taken as to whether to label ACMs. The decision will depend on the confidence in the
administration of the asbestos management system and whether communication with workers and contractors coming
to work on site can be effective.
Labelling ACMs should not be solely relied on as a control measure; however it is an effective method of preventing
exposure to building occupants (and, in particular, maintenance workers). If, for any reason, management procedures
fail, it may act as an effective last barrier to uncontrolled damage to the ACM.
It may not always be prudent or practical to label all installations of asbestos; for example high level items such as roof
sheets, flue cowls and soffits or items such as gaskets to pipe flanges, textured coating and floor tiles.
Encapsulate
When this recommendation has been given, the ACM is raw and requires encapsulating with a suitable sealant or the
existing sealant or covering has deteriorated and the installation requires either a complete or partial re-encapsulation.
Appendix 1 – Definitions & Recommended Guidance
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 39 of 44
We recommend that sealing or painting of insulating board, insulation or spray coatings should be undertaken by a
licensed contractor and is likely to be subject to a 14 day notification to the HSE, (as per the Control of Asbestos
Regulations 2012).
Repair
The material has sustained damage to some area or areas and requires attention to make good the material so that it
can be managed safely. This will often involve some element of decontamination if debris is associated with the
damage.
Remove
If an item is recommended for removal it has either sustained damage and is posing an increased risk in its current
condition; or due to its location it is considered high risk as it could easily be disturbed in the future. Materials
recommended for removal will be given one of the following recommendations:-
Removal by Licensed Contractor. This will include removal of AIB, Insulation, and Spray Coatings and is likely to be
subject to a 14 day notification to the HSE, (as per the Control of Asbestos Regulations 2012).
Removal by Approved Contractor. This will include removal of lower risk materials such as Asbestos Cement,
Bitumen Products, Reinforced Composites, and Floor Tiles etc. Some such works may be considered Notifiable Non-
Licensed Works.
The Control of Asbestos Regulations 2012 does not necessarily require such removal works to be undertaken by a
licensed contractor. However it is good practice, and we would strongly recommended that all removal works are
undertaken by a licensed contractor.
Restrict Access
Materials have been identified that are in a damaged condition often with associated debris that can be easily
disturbed. As such access to the area should be prevented to all persons until such a time when the area has been
deemed safe for reoccupation. This will usually be once removal works have been completed.
No Access – Inspection Required
Access to the given location was either not possible at all or only limited access was possible. In both instances there
is the potential for unidentified asbestos being present and as such the area must be treated as containing asbestos
until full access is possible.
Arrangements should be made at the earliest opportunity to revisit locations where access was not possible or access
was limited in order that such areas can be inspected fully.
Items and materials that are presumed to contain asbestos will also be given the recommendation of ‘No Access –
Inspection required’. In these instances the item or material should be treated as containing asbestos until
arrangements can be made to access such items or materials in order to carry out an inspection or sample to confirm
or otherwise the presence of asbestos.
No Recommendation Required
Asbestos has not been identified and as such no further action is required.
Recommended Guidance
To comply with and ensure that the requirements of section 2 & 3 of the Health and Safety at Work Act (as amended)
1974, the Management of Health and Safety at Work Regulations 1999, the Control of Asbestos Regulations 2012 and
the Control of Substances Hazardous to Health 2002 are met, the following recommendations should be implemented:
Appendix 1 – Definitions & Recommended Guidance
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 40 of 44
Undertake suitable and sufficient Risk Assessments of identified ACMs against normal occupation and maintenance
operations, in compliance with Regulations 3 of the Management of Health & Safety at Work Regulations 1999 and
Regulation 6 of the Control of Asbestos Regulations 2012.
The findings of the survey be brought to the attention of those persons who are likely to come in contact with asbestos, in
compliance with Section 2 and 3 of the Health and Safety at Work Act (as amended) 1974 and Regulation 9 of the Control
of Asbestos Regulations 2012.
Implement an Asbestos Management Policy, Plan and review process in compliance Regulation 4 of the Control of
Asbestos Regulations 2012.
During the course of the survey it may not have been possible to access all areas of the site. Details of areas requiring
further access is identified within the Data Sheets and Executive Summary of this report. In accordance with HSG 264,
asbestos is presumed to be present within these areas and should be treated accordingly until further inspection and
analysis of building fabric and services proves otherwise.
It is recommended that air monitoring is carried out within any areas where ACMs have been identified in order to assess
airborne fibre levels within adjacent occupied areas in relation to the clearance indicator, as documented by HSG 248 The
Analyst Guide.
Where asbestos debris or asbestos in poor condition has been found it is recommended that access is restricted to these
areas in accordance with Regulation 11 of the Control of Asbestos Regulations 2012 and that air monitoring is carried out
within adjacent areas in order to assess airborne fibre levels.
All identified asbestos to be appropriately identified and subject to Risk Assessment, management, and re-inspection.
Site specific recommendations in respect to the location and condition of asbestos materials identified during the
course of this inspection are detailed in the Survey Data Sheets and Asbestos register. In considering the management
of asbestos materials identified to date, these recommendations should be referred to and complied with.
It is recommended that work on, or removal of, both licensed and non licensed ACMs is undertaken by a licensed
asbestos removal contractor so that the Duty Holder / Client can have confidence that the contractor has provided the
correct level of training and has the experience and knowledge necessary to deal with these products safely.
It is a requirement of CAR 2012 that further intrusive investigations and sampling be carried out where any refurbishment,
maintenance, or similar activity is planned that may expose asbestos materials. This should be a refurbishment/demolition
survey as documented by HSG 264.
The findings of this report should not be solely relied upon in obtaining costs for proposed asbestos abatement work. Any
proposed abatement/removal of the asbestos should be undertaken against a detailed specification.
Appendix 2 – Material & Priority Assessment Algorithms
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 41 of 44
Where ACMs have been identified or presumed to be present a Material Assessment Algorithm has been calculated as detailed in HSG 264 and reproduced in line with the table overleaf. The Material Assessment is an assessment of the condition of the ACM, or the presumed ACM, and the likelihood of it releasing fibres in the event of it being disturbed in some way. This Material Assessment will give a good initial guide to the priority for management as it will identify the materials which will most readily release airborne fibres if disturbed. However, there are other factors to take into account when prioritising action. These are considered in the Priority Assessment which is described later. For each of the four variables given by the table a score is allocated. The four scores are added together to give a Material Assessment score of between 2 and 12. HIGH RISK 10-12 Materials with scores of 10 or more should be regarded as high risk with a significant potential to release fibres if disturbed; MEDIUM RISK 7- 9 Those materials with a score between 7 and 9 are regarded as medium risk to release fibres. LOW RISK 5-6 Materials with a score between 5 and 6 are low risk to release fibres. VERY LOW RISK 4 or less Scores of 4 or less are very low risk.
Section Sample
Variable Score Examples of Score
A Product type (or debris from product).
1 Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi rigid paint or decorative finishes, asbestos cement,
etc).
2 Asbestos insulating board, mill boards, other low-density insulation boards, asbestos textiles, gaskets, ropes and woven textiles, asbestos
paper and felt.
3 Thermal insulation (e.g.: pipe and boiler lagging), sprayed asbestos,
loose asbestos, asbestos mattresses and packing.
B Extent of damage/
deterioration.
0 Good condition: no visible damage.
1 Low damage: a few scratches or surface marks; broken edges on boards, tiles, etc.
2
Medium damage: significant breakage of materials or several small
areas where material has been damaged revealing loose asbestos fibres.
3 High damage or delamination of materials, sprays and thermal insulation. Visible asbestos debris.
C Surface Treatment
0 Composite materials containing asbestos: reinforced plastics, resins,
vinyl tiles.
1 Enclosed sprays and lagging, AIB (with exposed face painted or
encapsulated), unsealed cement sheets, etc.
2 Unsealed AIB, or encapsulated lagging and sprays.
3 Unsealed lagging and sprays.
D Asbestos type
1 Chrysotile.
2 Amphibole asbestos excluding Crocidolite.
3 Crocidolite.
Material Assessment Score = A + B + C + D
Appendix 2 – Material & Priority Assessment Algorithms
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 42 of 44
The Material Assessment identifies the high risk materials, that is, those which will most readily release airborne fibres if disturbed. It does not automatically follow that those materials assigned the highest score in the Material Assessment will be the materials that should be given priority for remedial action. Management priority must be determined by carrying out a Risk Assessment which will also take into account the likely maintenance activity; occupant activity; likelihood of disturbance; and human exposure potential. The Priority Assessment Algorithm looks at the likelihood of someone disturbing the ACM. Please note Priority Assessments have not been undertaken as part of this survey. A legal requirement to carry out a Risk Assessment for all work activities exists under the Management of Health and Safety at Work Regulations 1999. The requirement to assess the risk posed by asbestos is further enforced by the Control of Asbestos Regulations 2012. These regulations require that asbestos present in the workplace must not present a hazard to health The risks from asbestos should be assessed and managed for all identified or presumed ACMs. The Risk Assessment or priority rating will establish the likelihood of people being exposed to the hazard and identify the measures to be taken that will either eliminate the hazard or adequately control it. The Priority Assessment Score is calculated on the average scores for each of the four human exposure factors given by the table on the following page. It is the responsibility of the Duty Holder to complete the Priority Risk Assessment, and ensure it remains up to date and accurate.
Section Factor Score Examples of Score
Normal Occupant Activity Score = E
E Main Type of Activity
0 Rare Disturbance activity (e.g. Store Room)
1 Low Disturbance Activity (e.g. Office)
2 Periodic Disturbance (May contact ACMs)
3 High Level of disturbance (e.g. panel on door)
Likelihood of Disturbance Score = Average of F + G + H
F Location
0 Outdoors
1 Large Rooms or well ventilated Areas
2 Rooms up to 100sqm
3 Confined Spaces
G Accessibility
0 Usually Inaccessible or unlikely to be disturbed
1 Occasional Disturbance
2 Easily Disturbed
3 Routinely Disturbed
H Extent
0 Very Small Amounts
1 <10sqm or <10lm
2 >10sqm to <50sqm or >10lm to <50lm
3 <50sqm or >50lm
Human Exposure Potential Score = Average of I + J + K
I No of Occupants
0 None
1 1-3
2 4-10
3 >10
J Frequency of Use
0 Infrequent
1 Monthly
2 Weekly
3 Daily
K Average Time in Use
0 <1 Hour
1 >1 hour and <3 hours
2 >3 hours to <6 hours
3 >6 Hours
Maintenance Activity Score = Average of L + M
L Type of Activity
0 Minor disturbance e.g. possible contact
1 Low disturbance e.g. removing light bulb
2 Medium Disturbance
3 High levels of disturbance
Appendix 2 – Material & Priority Assessment Algorithms
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 43 of 44
M
Frequency of
Maintenance
0 ACM unlikely to be disturbed
1 1 per Year
2 >1 per year
3 >1 per Month
Risk Assessment The Risk Assessment Priority Algorithm is calculated by adding the Material Assessment Score obtained during the survey to the Priority Assessment Score.
HIGH RISK - 18 POINTS OR MORE The potential hazard arising from this category warrants urgent action. Immediate plans should be made for the removal/containment of the ACM. If delay in remedial action is likely to occur the affected area should initially be sealed-off and appropriate warning signs posted. MEDIUM RISK - 14-17 POINTS This category indicates that deterioration in any of the contributory factors may result in fibre release. Therefore all asbestos should be contained/sealed/encapsulated. LOW RISK - 9-13 Points This category indicates the need for regular monitoring. Although the current risk of fibre release is low, this material may suffer deterioration through age/local accidental damage. VERY LOW RISK 8 or less Similarly this category requires regular monitoring. Although the current risk of fibre release is low, this material may suffer deterioration through age/local accidental damage.
Appendix 3 – Survey Drawings
Version 08, May 2018 Life Environmental Services Issue No. 1
Reinspection Survey & PA B-82297 - Gorringe Park Primary Page 44 of 44
UP
UP
UP
UP
Biomass
UP
Boiler
0/109
Entrance Lobby
12.85 m²
E30
E1
E2
E3
E5E4
E6
E7
E9
E8
E11
E12
E17
E16
E15
E14E13
E21
E20
E19
E18 E22
E24
E23
E25
E26
E27E28
E29
E32E31
E33
E35
E34
E36
E37
E38
0/048
Lobby
4.66 m²
0/108
Store
5.27 m²
0/110
Corridor
13.52 m²
0/107
Store
8.53 m²
0/106
Kitchen
6.20 m²
0/105
Photocopy Room
7.36 m²
0/103
Corridor
2.74 m²
0/102
Classroom
46.51 m²
0/015
Deputy Head's Office
16.41 m²
0/104
Head's Office
25.36 m²
0/101
Classroom Year 4
47.04 m²
0/100
Classroom Year 4
47.17 m²
0/097
Toilet (Boys)
20.58 m²
0/098
Toilet (Girls)
20.86 m²
0/099
Lobby
3.53 m²
0/004A
Lobby
4.50 m²
0/075
Corridor
7.45 m²
0/003
Store
6.56 m²
0/001
Store
12.00 m²
0/078
Cleaning Cpd
2.57 m²
0/062
Kitchen
39.77 m²
0/060A
Store
2.11 m²
0/060
One To One Room
13.96 m²
0/093
One To One Room
10.23 m²
0/058
Toilet (Accessible)
6.79 m²
0/094
Corridor
8.47 m²
0/054
Corridor
8.44 m²
0/095
Office
10.75 m²
0/053
Toilet (Girls)
13.89 m²
0/052
Toilet (Boys)
13.60 m²
0/096
Cleaning Cpd
2.78 m²
0/111
Corridor
7.19 m²
0/112
Store
0.51 m²
0/114
Store
1.27 m²
0/113
Toilet (Pupils)
14.97 m²
0/116
Wood Pellet Store
5.57 m²
0/117
Plant Room
29.35 m²
0/017
Classroom Year 1
59.38 m²
0/018
Classroom Year 1
59.07 m²
0/019
Classroom Year 1
59.26 m²
0/118
Gas Cpd
1.55 m²
0/120
Toilet (Pupils)
10.41 m²
0/036
Corridor
15.93 m²
0/035A
Elect Intake
1.39 m²
0/035
Caretaker's Office
9.00 m²
0/036B
Cleaning Store
3.13 m²
0/038A
Store
1.41 m²
0/023B
Elect Intake
10.50 m²
0/121
Corridor
2.99 m²
0/039
Toilet (Staff/Female)
8.45 m²
0/039B
Toilet (Staff/Male)
1.38 m²
0/039A
Lobby
0.68 m²
0/022
Corridor
11.46 m²
0/022A
Toilet (Pupils)
13.20 m²
0/122
Store
5.11 m²
0/020
Store
13.30 m²
0/023
After School Club
46.47 m²
0/024
After School Club
47.09 m²
0/025
After School Club
47.22 m²
0/026
Group Room
16.99 m²
0/128
Toilet (Pupils)
15.27 m²
0/127
Corridor
18.80 m²
0/123
Hall
129.04 m²
0/033
Classroom Year 2
46.31 m²
0/032
Classroom Year 2
46.52 m²
0/031
Classroom Year 2
46.63 m²
0/090
Corridor
15.35 m²
0/124
Store
8.38 m²
0/091
Store
10.76 m²
0/126
Cloaks
17.33 m²
0/129
Store
1.09 m²
0/125
Office
5.63 m²
0/130
Reception Classroom
200.03 m²
0/132
Corridor
21.39 m²
0/131
Store
6.04 m²
0/134
Office
14.55 m²
0/133
Riser
0.72 m²
0/138
Store
3.98 m²
0/139
Riser
0.62 m²
0/136
Store
0.59 m²
0/137
Toilet (Pupils)
18.98 m²
0/135
Toilet (Accessible)
4.97 m²
0/140
Nursery
119.44 m²0/002
0/005
0/006
0/007
0/008 0/009 0/0100/
016
0/0300/034
0/036B
0/041
0/042
0/045
0/047
0/049
0/0510/0550/0560/057
0/059
0/061
0/0760/076A
0/004
0/077
0/080
0/08
1
0/08
2
0/085
0/086
0/115
OldSheds
Ground & External Floor PlanBlock A
GS190810/02
P
P
GS190810/26
GS180810/03
GS180810/04
SV54025/10
As GS180810/03
P P P
0/029 Boiler Room -Demolished
P
As GS190810/04
P
MP1
8081
0/03
MP1
8081
0/04
As S
V540
25/0
5
As M
P180
810/
03
As M
P180
810/
03
0/119
As M
P180
810/
05
0/037
MP1
8081
0/04
As MP180810/06As MP180810/06
As MP180810/06
P
PPP
PGS180810/10
As GS190810/04
As GS180810/15
As GS180810/03
P
GS180810/16As GS180810/15
PP
P
P
MP180810/01
MP180810/06
RoomDemolished
Removed
GS190810/05
Ext
Drawing Not to Scale Drawing should not be viewed in isolation. Please refer to Report Asbestos Register.
Drawn By:
Life Environmental Services Ltd.
4 Ducketts WharfSouth Street
Bishop’s Stortford CM23 3AR
Telephone: 0844 335 1281
Email: [email protected]
www.lifeenvironmental.co.uk
Registered in England No. 3053057
Revision No.: 2.5 Nov 2017
001
Job No.:
Key
- Location Number
- Asbestos Present
- No Access
(Please refer to register)
- Limited Access to Specified Level
- No Access to Specified LevelWithin Area
Within Area
- Limited Access
SP
S0001
S0001
X0001
P
S0001
- Outside Scope of Survey
- Asbestos Removed
- Positive Sample
- Cross Referenced Positive Sample
- Strongly Presumed Asbestos
- Presumed Asbestos
- Sample - No Asbestos Detected
Date:
Page:
SURVEY PLAN - Standard
Gorringe Park Primary
B-82297
WJ
01/03/2019
1 of 3
X0001- Cross Referenced Sample - No Asbestos Detected
UP
UP
UP
UP
UP
1/094
Shower Room
3.52 m²
1/093
Toilet (Staff)
2.51 m²
1/092
Stairwell
9.02 m²
1/076
Store
6.22 m²
1/075
Group Room
18.36 m²
1/095
Store
8.17 m²
1/036
Stairwell
4.84 m²
1/096
Store
1.81 m²
1/097
Stairwell
3.68 m²
1/071
Meeting Room
16.15 m²
1/072
Toilet (Staff)
4.62 m²
1/084
Corridor
2.41 m²
1/098
Stairwell
4.63 m²
1/069
Deputy Head's Office
18.52 m²
1/070
Store
9.55 m²
1/085A
Store
16.33 m²
1/099
Group Room
6.55 m²
1/066
Group Room
10.48 m²
1/067
Toilet (Pupils)
8.48 m²
1/063
1/064
1/065
1/068
1/073
1/07
6A
1/077
Lofts
First Floor PlanBlock A
Second Floor PlanBlock A
GS180810/10
As GS180810/10
As GS180810/10
SV54025/15
P
As MP180810/04
P
P
Drawing Not to Scale Drawing should not be viewed in isolation. Please refer to Report Asbestos Register.
Drawn By:
Life Environmental Services Ltd.
4 Ducketts WharfSouth Street
Bishop’s Stortford CM23 3AR
Telephone: 0844 335 1281
Email: [email protected]
www.lifeenvironmental.co.uk
Registered in England No. 3053057
Revision No.: 2.5 Nov 2017
001
Job No.:
Key
- Location Number
- Asbestos Present
- No Access
(Please refer to register)
- Limited Access to Specified Level
- No Access to Specified LevelWithin Area
Within Area
- Limited Access
SP
S0001
S0001
X0001
P
S0001
- Outside Scope of Survey
- Asbestos Removed
- Positive Sample
- Cross Referenced Positive Sample
- Strongly Presumed Asbestos
- Presumed Asbestos
- Sample - No Asbestos Detected
Date:
Page:
SURVEY PLAN - Standard
Gorringe Park Primary
B-82297
WJ
01/03/2019
2 of 3
X0001- Cross Referenced Sample - No Asbestos Detected
UP
UP
0/001
Store
10.51 m²
E4c E2c
E3c
E1c
E1bE3b
E2b
E4b
0/003
Kitchen
12.14 m²
0/006
Store
1.71 m²
0/000
Store
2.26 m²
0/001
Stairwell
3.24 m²
0/000
Lobby
1.71 m²
1/003
Bedroom
8.55 m²
1/002
Bedroom
7.54 m²
1/005
Bedroom
14.24 m²
1/001
Stairwell
6.60 m²
1/000
Bathroom
3.44 m²
0/002
0/004
0/005
First Floor PlanBlock B
Ground Floor PlanBlock B
Ground Floor PlanBlock C
P
As GS190810/02
SV54025/05
Drawing Not to Scale Drawing should not be viewed in isolation. Please refer to Report Asbestos Register.
Drawn By:
Life Environmental Services Ltd.
4 Ducketts WharfSouth Street
Bishop’s Stortford CM23 3AR
Telephone: 0844 335 1281
Email: [email protected]
www.lifeenvironmental.co.uk
Registered in England No. 3053057
Revision No.: 2.5 Nov 2017
001
Job No.:
Key
- Location Number
- Asbestos Present
- No Access
(Please refer to register)
- Limited Access to Specified Level
- No Access to Specified LevelWithin Area
Within Area
- Limited Access
SP
S0001
S0001
X0001
P
S0001
- Outside Scope of Survey
- Asbestos Removed
- Positive Sample
- Cross Referenced Positive Sample
- Strongly Presumed Asbestos
- Presumed Asbestos
- Sample - No Asbestos Detected
Date:
Page:
SURVEY PLAN - Standard
Gorringe Park Primary
B-82297
WJ
01/03/2019
3 of 3
X0001- Cross Referenced Sample - No Asbestos Detected