Data sheet
Key features
•PowerfulArubaLayer3modularswitchseriesdelivershigh-performance,lowlatencyandresiliency.
•HPESmartRateforhigh-speedmulti-gigabitbandwidthandPoE+power.
•Scalablelinerate40GbEforwirelesstrafficaggregation.
•ReadyforinnovativeSDNapplicationswithOpenFlowsupport.
•SupportsClearPassPolicyManagerandAirwaveNetworkManagement.
Product overview
TheAruba5400Rzl2SwitchSeriesisanindustry-leadingmobilecampusaccesssolutionwithHPESmartRatemulti-gigabitportsforhigh-speedconnectivityandbandwidthfornextwave802.11acdevices.Itbringsenterprise-classresiliencyandinnovativeflexibilityandscalabilitytomobile-firstnetworks.TheAruba5400RdeliversrobustvirtualizationwithAllianceOnesolutions,hitlessfailover,enhancedQoS,andsecuritywithadvancedLayer3featureswithnoadd-onsoftwarelicensingrequired.
Basedonthe6thgenerationProVisionASIC,theAruba5400Rzl2SwitchSerieshasahigh-speed,high-capacityarchitecturewith2Tbpscrossbarswitchingfabricwithlow2.1μlatency,unprecedentedprogrammability,andleadingedgeSDNapplications.Thisseriesoffersflexibleconnectivityoptionswith6-or12-slotcompactchassis,linerate40GbE,upto96linerate10GbEportsandupto288portsofPoE+.TheAruba5400RisSDN-readywithOpenFlowsupportandprovidesaconsistentwired/wirelessuserexperiencewithClearPassPolicyManagerandAirwaveNetworkManagement.
Aruba 5400R zl2 Switch Series
Page 2Data sheet
Features and benefits
Software-defined networking•OpenFlow
SupportsOpenFlow1.0and1.3specificationstoenableSDNbyallowingseparationofthedata(packetforwarding)andcontrol(routingdecision)paths
•FullyflexibleOpenFlow
CreatescustomOpenFlowpipelines(processingstages)on-demandtosupportnewSDNapplications(requiresv3modules)
Unified Wired and Wireless•NEWClearPassPolicyManager
SupportsunifiedwiredandwirelesspoliciesusingArubaClearPassPolicyManager
•HTTPredirectfunction
SupportsHPEIntelligentManagementCenter(IMC)bringyourowndevice(BYOD)solution
•Switchauto-configuration
AutomaticallyconfiguresswitchfordifferentsettingssuchasVLAN,CoS,PoEmaxpower,andPoEprioritywhenArubaAPisdetected
•NewUserRole
Asetofswitch-basedpoliciesinareassuchassecurity,authentication,andQoS.AUserRolecanbeassignedtoagroupofusersordevices,usingswitchconfigurationorClearPass
•NEWPer-portTunneledNode
Providesecuredtunneltotransportnetworktrafficonaper-portbasistoArubaController.AuthenticationandnetworkpolicieswillbeappliedandenforcedattheController
Quality of Service (QoS)•Advancedclassifier-basedQoS
ClassifiestrafficusingmultiplematchcriteriabasedonLayer2,3,and4information;appliesQoSpoliciessuchassettingprioritylevelandratelimittoselectedtrafficonaper-portorperVLANbasis
•Trafficprioritization
Allowsreal-timetrafficclassificationintoeightprioritylevelsmappedtoeightqueues
Page 3Data sheet
•Bandwidthshaping
–Port-basedratelimiting
providesper-portingress-/egress-enforcedincreasedbandwidth
–Classifier-basedratelimiting
usesanaccesscontrollist(ACL)toenforceincreasedbandwidthforingresstrafficoneachport
–Reducedbandwidth
providesper-port,per-queueegress-basedreducedbandwidth
•ClassofService(CoS)
SetstheIEEE802.1pprioritytagbasedonIPaddress,IPTypeofService(ToS),Layer3protocol,TCP/UDPportnumber,sourceport,andDiffServ
Management•NEWZero-TouchProVisioning(ZTP)
SimplifiesinstallationoftheswitchinfrastructureusingArubaActivate-basedorDHCP-basedprocesswithAirWaveNetworkManagement
•Remoteintelligentmirroring
Mirrorsselectedingress/egresstrafficbasedonACL,port,MACaddress,orVLANtoalocalorremoteHPE8200zl,6600,6200yl,5400zl,5400R,3500,or3800Switchlocatedanywhereonthenetwork
•RMON,XRMON,andsFlow®v5
Provideadvancedmonitoringandreportingcapabilitiesforstatistics,history,alarms,andevents
•IEEE802.1ABLinkLayerDiscoveryProtocol(LLDP)
Advertisesandreceivesmanagementinformationfromadjacentdevicesonanetwork,facilitatingeasymappingbynetworkmanagementapplications
•Uni-DirectionalLinkDetection(UDLD)
SupportHewlettPackardEnterprise(HPE)UDLDandDLDPprotocolstomonitoracablebetweentwoswitchesandshutdowntheportsonbothendsifthecableisbroken
•Managementsimplicity
ProvidescommonsoftwarefeaturesandCLIimplementationacrossallHPEProVision-basedswitches(includingthezlandylswitches)
•Commandauthorization
LeveragesRADIUStolinkacustomlistofCLIcommandstoanindividualnetworkadministrator’slogin;anaudittraildocumentsactivity
Page 4Data sheet
•Friendlyportnames
Allowsassignmentofdescriptivenamestoports
•Dualflashimages
Providesindependentprimaryandsecondaryoperatingsystemfilesforbackupwhileupgrading
•Multipleconfigurationfiles
Storeseasilytotheflashimage
•ComwareCLI
–Comware-compatibleCLI
bridgestheexperienceofHPEComwareCLIuserswhoareusingtheHPEProVisionsoftwareCLI
–DisplayandfundamentalComwareCLIcommands
areembeddedintheswitchCLIasnativecommands;displayoutputisformattedasonComware-basedswitches,andfundamentalcommandsprovideaComware-familiarinitialswitchsetup
–ConfigurationComwareCLIcommands
whenComwarecommandsareentered,CLIhelpiselicitedtoformulatethecorrectProVisionsoftwareCLIcommand
Connectivity•IEEE802.3azEnergyEfficientEthernet
Lowerspowerconsumptioninperiodsoflowlinkusage(supportedonv2zl10/100/1000and10/100modules)
•IEEE802.3afPoweroverEthernet(PoE)
Providesupto15.4WperporttoIEEE802.3af-compliantPoE-powereddevicessuchasIPphones,wirelessaccesspoints,andsecuritycameras
•IEEE802.3atPoweroverEthernetPlus
Providesupto30Wperport,forupto288portssimultaneously,forPoE-andPoE+-powereddevices,suchasvideoIPphones,IEEE802.11nwirelessaccesspoints,andadvancedpan/zoom/tiltsecuritycameras
•PrestandardPoEsupport
DetectsandprovidespowertoprestandardPoEdevices
Page 5Data sheet
•High-densityportconnectivity
Providesupto12interfacemoduleslotsandupto288wire-speed10/100/1000PoE-enabledportsor9610GbEportspersystem
•Jumboframes
OnGigabitEthernetand10-GigabitEthernetports,jumboframesallowhigh-performanceremotebackupanddisaster-recoveryservices
•Auto-MDIX
Providesautomaticadjustmentsforstraight-throughorcrossovercablesonall10/100and10/100/1000ports
•IPv6
– IPv6host
enablesswitchestobemanagedinanIPv6network
–Dualstack(IPv4andIPv6)
transitionsfromIPv4toIPv6,supportingconnectivityforbothprotocols
–MLDsnooping
forwardsIPv6multicasttraffictotheappropriateinterface
– IPv6ACL/QoS
supportsACLandQoSforIPv6networktraffic
– IPv6routing
supportsstatic,RIPng,andOSPFv3routingprotocols
–6in4tunneling
supportsencapsulationofIPv6trafficinIPv4packets
–Security
providesRAguard,DHCPv6protection,dynamicIPv6lockdown,andNDsnooping
Performance•High-speed,high-capacityarchitecture
2Tbpscrossbarswitchingfabricprovidesintra-moduleandinter-moduleswitchingwith785.7millionppsthroughputonthepurpose-builtProVisionASICs
•Selectablequeueconfigurations
Allowsforincreasedperformancebyselectingthenumberofqueuesandassociatedmemorybufferingthatbestmeettherequirementsofthenetworkapplications
Page 6Data sheet
Resiliency and high availability•VirtualSwitchingFramework(VSF)
Createsonevirtualresilientswitchfromtwoswitches;serversorswitchescanbeattachedusingstandardLACPforautomaticloadbalancingandhighavailability;simplifynetworkoperationbyreducetheneedforcomplexprotocolslikeSpanningTreeProtocol(STP),Equal-CostMultipath(ECMP),andVRRP(requiresv3modules)
•VirtualRouterRedundancyProtocol(VRRP)
AllowsgroupsoftworouterstodynamicallybackeachotheruptocreatehighlyavailableroutedenvironmentsforIPv4andIPv6networks
•Nonstopswitching
Improvesnetworkavailabilitytobettersupportcriticalapplicationssuchasunifiedcommunicationandmobility;interfaceandfabricmodulescontinueswitchingtrafficduringfailoverfromactivetostandbymanagementmodule
•Nonstoprouting
EnhancesLayer3highavailability;OSPFv2/v3andVRRPwillcontinuetooperateandroutenetworktrafficduringfailoverfromanactivetoastandbymanagementmodule
•Redundantmanagementandpower
Provideenhancedsystemavailabilityandcontinuityofoperations
•IEEE802.1sMultipleSpanningTreeProtocol
ProvideshighlinkavailabilityinmultipleVLANenvironmentsbyallowingmultiplespanningtrees;encompassesIEEE802.1DSpanningTreeProtocolandIEEE802.1wRapidSpanningTreeProtocol
•IEEE802.3adLinkAggregationControlProtocol(LACP)andHPEporttrunking
Supportupto144trunks,eachwithuptoeightlinks(ports)pertrunk
•Distributedtrunking
Enablesloop-freeandredundantnetworktopologywithoutusingSpanningTreeProtocol;allowsaserverorswitchtoconnecttotwoswitchesusingonelogicaltrunkforredundancyandloadsharing
•Optionalredundantpowersupply
Providesuninterruptedpowerandallowshot-swappingoftheredundantpowersupplieswheninstalled
•Hot-swappablemodules
Allowsdissimilarmodules,andpowersuppliesinaredundantpowersupplyconfigurationtobeaddedorswappedwithoutinterruptingthenetwork
•Sparingsimplicity
HPEzl-commonaccessories(interfacemodulesandpowersupplies)
Page 7Data sheet
•UplinkFailureDetection
Providesactive-standbynetworkpathredundancyforserversthatareconfiguredforactive-standbyNICteaming
•SmartLink
Provideseasy-to-configurelinkredundancyofactiveandstandbylinks
Layer 2 switching•VLANsupportandtagging
SupportstheIEEE802.1Qstandardand4,094VLANssimultaneously
•IEEE802.1vprotocolVLANs
Isolateselectnon-IPv4protocolsautomaticallyintotheirownVLANs
•NEWVxLAN
Encapsulation(tunneling)protocolforoverlaynetworkthatenablesamorescalablevirtualnetworkdeployment(requiresv3modules)
•NEWGVRPandMVRP
AllowsautomaticlearninganddynamicassignmentofVLANs
•IEEE802.1adQ-in-Q
IncreasesthescalabilityofanEthernetnetworkbyprovidingahierarchicalstructure;connectsmultipleLANsonahigh-speedcampusormetronetwork
•MAC-basedVLAN
Providesgranularcontrolandsecurity;usesRADIUStomapaMACaddress/usertospecificVLANs(requiresv2orhighermodules)
•RapidPer-VLANSpanningTree(RPVST+)
AllowseachVLANtobuildaseparatespanningtreetoimprovelinkbandwidthusage;iscompatiblewithPVST+
•HPEswitchmeshing
Dynamicallyloadbalancesacrossmultipleactiveredundantlinkstoincreaseavailableaggregatebandwidth;allowsconcurrentLayer3routingwithv2orhighermodules
Layer 3 services•NEWBidirectionalForwardingDetection(BFD)
EnableslinkconnectivitymonitoringandreducesnetworkconvergencetimeforOSPFv2andVRRP(requiresv3modules)
•UserDatagramProtocol(UDP)helperfunction
AllowsUDPbroadcaststobedirectedacrossrouterinterfacestospecificIPunicastorsubnetbroadcastaddressesandpreventsserverspoofingforUDPservicessuchasDHCP
Page 8Data sheet
•Loopbackinterfaceaddress
DefinesanaddressinRoutingInformationProtocol(RIP)andOpenStandardPathFirst(OSPF),improvingdiagnosticcapability
•Routemaps
Providemorecontrolduringrouteredistribution;allowfilteringandalteringofroutemetrics
•DHCPserver
CentralizesandreducesthecostofIPv4addressmanagement
Layer 3 routing•StaticIProuting
ProvidesmanuallyconfiguredroutingforbothIPv4andIPv6networks
•RoutingInformationProtocol(RIP)
ProvidesRIPv1,RIPv2,andRIPngrouting
•OSPF
ProvidesOSPFv2forIPv4routingandOSPFv3forIPv6routing
•Policy-basedrouting
Usesaclassifiertoselecttrafficthatcanbeforwardedbasedonpolicysetbythenetworkadministrator(requiresv2orhighermodules)
•BorderGatewayProtocol(BGP)
ProvidesIPv4BorderGatewayProtocolrouting,whichisscalable,robust,andflexible
Security•Accesscontrollists(ACLs)
ProvidefilteringbasedontheIPfield,source/destinationIPaddress/subnet,andsource/destinationTCP/UDPportnumberonaper-VLANorper-portbasis
•Multipleuserauthenticationmethods
– IEEE802.1Xusersperport
providesauthenticationofmultipleIEEE802.1Xusersperport
–Web-basedauthentication
authenticatesfromaWebbrowserforclientsthatdonotsupportIEEE802.1Xsupplicant
–MAC-basedauthentication
clientisauthenticatedwiththeRADIUSserverbasedontheclient’sMACaddress
–ConcurrentIEEE802.1X,Web,andMACauthenticationschemesperport
switchportacceptsupto32sessionsofIEEE802.1X,Web,andMACauthentications
Page 9Data sheet
•NEWPrivateVLAN
Providesnetworksecuritybyrestrictingpeer-to-peercommunicationtopreventavarietyofmaliciousattacks;typicallyaswitchportcanonlycommunicatewithotherportsinthesamecommunityand/oranuplinkport,regardlessofVLANIDordestinationMACaddress
•DHCPprotection
BlocksDHCPpacketsfromunauthorizedDHCPservers,preventingdenial-of-serviceattacks
•Securemanagementaccess
Deliverssecureencryptionofallaccessmethods(CLI,GUI,orMIB)throughSSHv2,SSL,and/orSNMPv3
•SwitchCPUprotection
Providesautomaticprotectionagainstmaliciousnetworktraffictryingtoshutdowntheswitch
•ICMPthrottling
DefeatsICMPdenial-of-serviceattacksbyenablinganyswitchporttoautomaticallythrottleICMPtraffic
•Identity-drivenACL
EnablesimplementationofahighlygranularandflexibleaccesssecuritypolicyandVLANassignmentspecifictoeachauthenticatednetworkuser
•STPBPDUportprotection
BlocksBridgeProtocolDataUnits(BPDUs)onportsthatdonotrequireBPDUs,preventingforgedBPDUattacks
•DynamicIPlockdown
WorkswithDHCPprotectiontoblocktrafficfromunauthorizedhosts,preventingIPsourceaddressspoofing
•DynamicARPprotection
BlocksARPbroadcastsfromunauthorizedhosts,preventingeavesdroppingortheftofnetworkdata
•STProotguard
Protectstherootbridgefrommaliciousattacksorconfigurationmistakes
Page 10Data sheet
•Detectionofmaliciousattacks
Monitors10typesofnetworktrafficandsendsawarningwhenananomalythatpotentiallycanbecausedbymaliciousattacksisdetected
•Portsecurity
AllowsaccessonlytospecifiedMACaddresses,whichcanbelearnedorspecifiedbytheadministrator
•MACaddresslockout
PreventsparticularconfiguredMACaddressesfromconnectingtothenetwork
•Source-portfiltering
Allowsonlyspecifiedportstocommunicatewitheachother
•RADIUS/TACACS+
Easesswitchmanagementsecurityadministrationbyusingapasswordauthenticationserver
•SecureShell
EncryptsalltransmitteddataforsecureremoteCLIaccessoverIPnetworks
•SecureSocketsLayer(SSL)
EncryptsallHTTPtraffic,allowingsecureaccesstothebrowser-basedmanagementGUIintheswitch
•SecureFTP
Allowssecurefiletransfertoandfromtheswitch;protectsagainstunwantedfiledownloadsorunauthorizedcopyingofaswitchconfigurationfile
•ManagementInterfaceWizard
HelpssecuremanagementinterfacessuchasSNMP,telnet,SSH,SSL,Web,andUSBatthedesiredlevel
•Switchmanagementlogonsecurity
HelpssecureswitchCLIlogonbyoptionallyrequiringeitherRADIUSorTACACS+authentication
•Securitybanner
Displaysacustomizedsecuritypolicywhenuserslogintotheswitch
•IEEE802.1AEMACsec
Providessecurityonalinkbetweentwoswitchports(1Gbpsor10Gbps)usingstandardencryptionandauthentication.(requiresv3modules)
Page 11Data sheet
Convergence•IPmulticastrouting
IncludesPIMSparseandDensemodestorouteIPmulticasttraffic
•IPmulticastsnooping(data-drivenIGMP)
PreventsfloodingofIPmulticasttraffic
•LLDP-MED(MediaEndpointDiscovery)
DefinesastandardextensionofLLDPthatstoresvaluesforparameterssuchasQoSandVLANtoautomaticallyconfigurenetworkdevicessuchasIPphones
•PoEallocations
Supportsmultiplemethods(automatic,IEEE802.3afclass,LLDP-MED,oruser-specified)toallocatePoEpowerformoreefficientenergysavings
•AutoVLANconfigurationforvoice
–RADIUSVLAN
usesastandardRADIUSattributeandLLDP-MEDtoautomaticallyconfigureaVLANforIPphones
–CDPv2
usesCDPv2toconfigurelegacyIPphones
•LocalMACAuthentication
AssignsattributessuchasVLANandQoSusinglocallyconfiguredprofilethatcanbealistofMACprefixes
Warranty and support •LimitedLifetimeWarranty
Seehpe.com/networking/warrantysummaryforwarrantyandsupportinformationincludedwithyourproductpurchase.
•Softwarereleases
Tofindsoftwareforyourproduct,refertohpe.com/networking/support;fordetailsonthesoftwarereleasesavailablewithyourproductpurchase,refertohpe.com/networking/warrantysummary
Page 12Data sheet
HPE 5400R zl2 Switch Series
Specifications
HPE 5406R zl2 Switch (J9821A) HPE 5412R zl2 Switch (J9822A) HPE 5406R-44G-PoE+/2SFP+ (No PSU) v2 zl2 Switch (J9823A)
Includedaccessories 1HPE5400Rzl2ManagementModule(J9827A)1HPE5406Rzl2SwitchFanTray(J9831A)
1HPE5400Rzl2ManagementModule(J9827A)1HPE5412Rzl2SwitchFanTray(J9832A)
1HPE5400Rzl2ManagementModule(J9827A)1HPE5406Rzl2SwitchFanTray(J9831A)1HPE24-portGig-TPoE+v2zlModule(J9534A)1HPE20-portGig-TPoE+/2-port10GbESFP+v2zlModule(J9536A)
I/Oportsandslots 6openmoduleslotsSupportsamaximumof144autosensing10/100/1000portsor144SFPportsor48SFP+portsor48HPESmartRateMulti-Gigabitor1240GbEports,oracombination
12openmoduleslotsSupportsamaximumof288autosensing10/100/1000portsor288SFPportsor96SFP+portsor96HPESmartRateMulti-Gigabitor2440GbEports,oracombination
44RJ-45autosensing10/100/1000PoE+ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T,IEEE802.3atPoE+);MediaType:Auto-MDIX;Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly2open10GbESFP+transceiverslots4openmoduleslotsSupportsamaximumof144autosensing10/100/1000portsor144SFPportsor48SFP+portsor48HPESmartRateMulti-Gigabitor1240GbEports,oracombination
Powersupplies 2powersupplyslots1minimumpowersupplyrequired(orderedseparately)
4powersupplyslots2minimumpowersuppliesrequired(orderedseparately)
2powersupplyslots1minimumpowersupplyrequired(orderedseparately)
Fantray Includes:1xJ9831A1fantrayslot
Includes:1xJ9832A1fantrayslot
Includes:1xJ9831A1fantrayslot
PhysicalcharacteristicsDimensions
Weight
17.5(w)x17.75(d)x6.9(h)in.(44.45x45.09x17.53cm)(4Uheight)24.5lb(11.11kg)
17.5(w)x17.75(d)x12.1(h)in.(44.45x45.09x30.73cm)(7Uheight)38.1lb(17.28kg)
17.5(w)x17.75(d)x6.9(h)in.(44.45x45.09x17.53cm)(4Uheight)28.11lb(12.75kg)
Memoryandprocessorv3GigabitModule
v2GigabitModule
v310GModule
v210GModule
v340GModule
ManagementModule
DualARM®CoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@450MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@550MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:[email protected],16MBflash,1GBSDCard,4GBDDR3SODIMM
DualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@450MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@550MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:[email protected],16MBflash,1GBSDCard,4GBDDR3SODIMM
DualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@450MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@550MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:[email protected],16MBflash,1GBSDCard,4GBDDR3SODIMM
Page 13Data sheet
HPE 5406R zl2 Switch (J9821A) HPE 5412R zl2 Switch (J9822A) HPE 5406R-44G-PoE+/2SFP+ (No PSU) v2 zl2 Switch (J9823A)
Mountingandenclosure MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded);Horizontalsurfacemountingonly
MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded);Horizontalsurfacemountingonly
MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded);Horizontalsurfacemountingonly
Performance1000MbLatency10GbpsLatency40GbpsLatencyThroughputRouting/SwitchingcapacitySwitchfabricspeedRoutingtablesize
MACaddresstablesize
IPv6ReadyCertified<2.8µs(FIFO64-bytepackets)<1.8µs(FIFO64-bytepackets)<1.5µs(FIFO64-bytepackets)Upto571.4Mpps960Gbps1015Gbps10000entries(IPv4),5000entries(IPv6)
64000entries
IPv6ReadyCertified<2.8µs(FIFO64-bytepackets)<1.8µs(FIFO64-bytepackets)<1.5µs(FIFO64-bytepackets)Upto1142.8Mpps1920Gbps2030Gbps10000entries(IPv4),5000entries(IPv6)
64000entries
IPv6ReadyCertified<2.8µs(FIFO64-bytepackets)<1.8µs(FIFO64-bytepackets)<1.5µs(FIFO64-bytepackets)Upto571.4Mpps960Gbps1015Gbps10000entries(IPv4),5000entries(IPv6)64000entries
EnvironmentOperatingtemperature
OperatingrelativehumidityNonoperating/StoragetemperatureNonoperating/StoragerelativehumidityAltitudeAcoustic
32°Fto113°F(0°Cto45°C);0°Cto40°CwithJ8177Ctransceiverinstalled,0°Cto35°CwithFIPSOpacityShieldinstalled15%to95%@113°F(45°C),noncondensing-40°Fto158°F(-40°Cto70°C)15%to95%@149°F(65°C),noncondensingUpto10,000ft(3km)Power:44dB,Pressure:31.7dBISO7779,ISO9296
32°Fto113°F(0°Cto45°C);0°Cto40°CwithJ8177Ctransceiverinstalled,0°Cto35°CwithFIPSOpacityShieldinstalled15%to95%@113°F(45°C),noncondensing-40°Fto158°F(-40°Cto70°C)15%to95%@149°F(65°C),noncondensingUpto10,000ft(3km)Power:49dB,Pressure:35.7dBISO7779,ISO9296
32°Fto113°F(0°Cto45°C);0°Cto40°CwithJ8177Ctransceiverinstalled,0°Cto35°CwithFIPSOpacityShieldinstalled15%to95%@113°F(45°C),noncondensing-40°Fto158°F(-40°Cto70°C)15%to95%@149°F(65°C),noncondensingUpto10,000ft(3km)Power:44dB,Pressure:31.7dBISO7779,ISO9296
ElectricalcharacteristicsFrequency80plus.orgCertificationDescription
Maximumheatdissipation
Voltage
Idlepower
Notes
50/60HzGoldDoesnotcomewithpowersupply.Twopowersupplyslotsareavailable;threedifferentpowersuppliesareavailable.Seepowersupplyproductsforadditionalspecifications.2450BTU/hr(2584kJ/hr),(max.non-PoE);3700BTU/hr(3903kJ/hr),(max.usingPoE)100–127/200–240VAC,rated(dependingonpowersupplychosen)
HeatdissipationdoesnotincludeheatdissipatedbythePoE-powereddevicesthemselves.
50/60HzGoldDoesnotcomewithpowersupply.Fourpowersupplyslotsareavailable;threedifferentpowersuppliesareavailable.Seepowersupplyproductsforadditionalspecifications.4900BTU/hr(5169kJ/hr),(max.non-PoE);7400BTU/hr(7,807kJ/hr),(max.usingPoE)100–127/200–240VAC,rated(dependingonpowersupplychosen)
HeatdissipationdoesnotincludeheatdissipatedbythePoE-powereddevicesthemselves.Whenmorethanfourpowercordsareinstalledina5412Rzl2switchchassis,additionalinstallationrequirementsareneeded.RefertotheHPE5400Rzl2SwitchesQuickSetupGuideandSafety/RegulatoryInformationmanualfordetails.
50/60HzGoldDoesnotcomewithpowersupply.Twoopenpowersupplyslotsareavailable;threedifferentpowersuppliesareavailable.Seepowersupplyproductsforadditionalspecifications.2450BTU/hr(2584.75kJ/hr),(max.non-PoE);3700BTU/hr(3903kJ/hr),(max.usingPoE)110–127/200–240VAC,rated(dependingonpowersupplychosen)215WIdlepoweristheactualpowerconsumptionofthedevicewithnoportsconnected.
Page 14Data sheet
HPE 5406R zl2 Switch (J9821A) HPE 5412R zl2 Switch (J9822A) HPE 5406R-44G-PoE+/2SFP+ (No PSU) v2 zl2 Switch (J9823A)
Safety CSA22.2No.60950;UL60950;IEC60950;EN60950
CSA22.2No.60950;UL60950;IEC60950;EN60950
CSA22.2No.60950;UL60950;IEC60950;EN60950
Emissions FCCpart15ClassA;EN55022/CISPR22ClassA
FCCpart15ClassA;EN55022/CISPR22ClassA
FCCpart15ClassA;EN55022/CISPR22ClassA
ImmunityENESD
RadiatedEFT/Burst
SurgeConductedPowerfrequencymagneticfield
HarmonicsFlicker
EN55024,CISPR24IEC61000-4-2;4kVCD,8kVAD;HPEENV.765.002IEC61000-4-3;3V/mIEC61000-4-4;1.0kV(powerline),0.5kV(signalline)IEC61000-4-5;1kV/2kVAC,1kVsignal,0.5kVDCIEC61000-4-6;3VrmsIEC61000-4-8;1A/m,50or60HzIEC61000-4-11;>95%reduction,0.5period;30%reduction,25periodsEN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
EN55024,CISPR24IEC61000-4-2;4kVCD,8kVAD;HPEENV.765.002IEC61000-4-3;3V/mIEC61000-4-4;1.0kV(powerline),0.5kV(signalline)IEC61000-4-5;1kV/2kVAC,1kVsignal,0.5kVDCIEC61000-4-6;3VrmsIEC61000-4-8;1A/m,50or60HzIEC61000-4-11;>95%reduction,0.5period;30%reduction,25periodsEN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
EN55024,CISPR24IEC61000-4-2;4kVCD,8kVAD;HPEENV.765.002IEC61000-4-3;3V/mIEC61000-4-4;1.0kV(powerline),0.5kV(signalline)IEC61000-4-5;1kV/2kVAC,1kVsignal,0.5kVDCIEC61000-4-6;3VrmsIEC61000-4-8;1A/m,50or60HzIEC61000-4-11;>95%reduction,0.5period;30%reduction,25periodsEN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;Command-lineinterface;Webbrowser;Configurationmenu;Out-of-bandmanagement(RJ-45Ethernet);SNMPManager;Out-of-bandmanagement(serialRS-232CormicroUSB)AirWaveNetworkManagement
IMC—IntelligentManagementCenter;Command-lineinterface;Webbrowser;Configurationmenu;Out-of-bandmanagement(RJ-45Ethernet);SNMPManager;Out-of-bandmanagement(serialRS-232CormicroUSB)AirWaveNetworkManagement
IMC—IntelligentManagementCenter;Command-lineinterface;Webbrowser;Configurationmenu;Out-of-bandmanagement(RJ-45Ethernet);SNMPManager;Out-of-bandmanagement(serialRS-232CormicroUSB)AirWaveNetworkManagement
Notes Supported1GSFPtransceiversarerevision“B”orlater(productnumberendswiththeletter“B”orlater;Forexample,J9142B,J8177C).
Supported1GSFPtransceiversarerevision“B”orlater(productnumberendswiththeletter“B”orlater;Forexample,J9142B,J8177C).
Supported1GSFPtransceiversarerevision“B”orlater(productnumberendswiththeletter“B”orlater;Forexample,J9142B,J8177C).
Services RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/services fordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
Page 15Data sheet
HPE 5400R zl2 Switch Series
Specifications (continued)
HPE 5412R-92G-PoE+/2SFP+ (No PSU) v2 zl2 Switch (J9825A)
HPE 5406R-44G-PoE+/4SFP (No PSU) v2 zl2 Switch (J9824A)
HPE 5412R-92G-PoE+/4SFP (No PSU) v2 zl2 Switch (J9826A)
Includedaccessories 1HPE5400Rzl2ManagementModule(J9827A)1HPE5412Rzl2SwitchFanTray(J9832A)3HPE24-portGig-TPoE+v2zlModule(J9534A)1HPE20-portGig-TPoE+/2-port10GbESFP+v2zlModule(J9536A)
1HPE5400Rzl2ManagementModule(J9827A)1HPE5406Rzl2SwitchFanTray(J9831A)1HPE24-portGig-TPoE+v2zlModule(J9534A)1HPE20-portGig-TPoE+/4-portSFPv2zlModule(J9535A)
1HPE5400Rzl2ManagementModule(J9827A)1HPE5412Rzl2SwitchFanTray(J9832A)3HPE24-portGig-TPoE+v2zlModule(J9534A)1HPE20-portGig-TPoE+/4-portSFPv2zlModule(J9535A)
I/Oportsandslots 92RJ-45autosensing10/100/1000PoE+ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T,IEEE802.3atPoE+);MediaType:Auto-MDIX;Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly2open10GbESFP+transceiverslots8openmoduleslotsSupportsamaximumof288autosensing10/100/1000portsor288SFPportsor96SFP+portsor96HPESmartRateMulti-Gigabitor2440GbEports,oracombination
44RJ-45autosensing10/100/1000ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T);MediaType:Auto-MDIX;Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly4openmini-GBIC(SFP)slots4openmoduleslotsSupportsamaximumof144autosensing10/100/1000portsor144SFPportsor48SFP+portsor48HPESmartRateMulti-Gigabitor1240GbEports,oracombination
92RJ-45autosensing10/100/1000PoE+ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T,IEEE802.3atPoE+);MediaType:Auto-MDIX;Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly4openmini-GBIC(SFP)slots8openmoduleslotsSupportsamaximumof288autosensing10/100/1000portsor288SFPportsor96SFP+portsor96HPESmartRateMulti-Gigabitor2440GbEports,oracombination
Powersupplies 4powersupplyslots2minimumpowersuppliesrequired(orderedseparately)
2powersupplyslots1minimumpowersupplyrequired(orderedseparately)
4powersupplyslots2minimumpowersuppliesrequired(orderedseparately)
Fantray Includes:1xJ9832A1fantrayslot
Includes:1xJ9831A1fantrayslot
Includes:1xJ9832A1fantrayslot
PhysicalcharacteristicsDimensions
Weight
17.5(w)x17.75(d)x12.1(h)in.(44.45x45.09x30.73cm)(7Uheight)45.19lb(20.5kg)
17.5(w)x17.75(d)x6.9(h)in.(44.45x45.09x17.53cm)(4Uheight)26.19lb(11.88kg)
17.5(w)x17.75(d)x12.1(h)in.(44.45x45.09x30.73cm)(7Uheight)45.4lb(20.59kg)
Memoryandprocessorv3GigabitModule
v2GigabitModule
v310GModule
v210GModule
v340GModule
ManagementModule
DualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@450MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@550MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:[email protected],16MBflash,1GBSDCard,4GBDDR3SODIMM
DualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@450MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@550MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1;Packetbuffersize:[email protected],16MBflash,1GBSDCard,4GBDDR3SODIMM
DualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@450MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@550MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:[email protected],16MBflash,1GBSDCard,4GBDDR3SODIMM
Page 16Data sheet
HPE 5412R-92G-PoE+/2SFP+ (No PSU) v2 zl2 Switch (J9825A)
HPE 5406R-44G-PoE+/4SFP (No PSU) v2 zl2 Switch (J9824A)
HPE 5412R-92G-PoE+/4SFP (No PSU) v2 zl2 Switch (J9826A)
Mounting and enclosure MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded);Horizontalsurfacemountingonly
MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded);Horizontalsurfacemountingonly
MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded);Horizontalsurfacemountingonly
Performance1000MbLatency10GbpsLatency40GbpsLatencyThroughputRouting/SwitchingcapacitySwitchfabricspeedRoutingtablesizeMACaddresstablesize
IPv6ReadyCertified<2.8µs(FIFO64-bytepackets)<1.8µs(FIFO64-bytepackets)<1.5µs(FIFO64-bytepackets)Upto1142.8Mpps1920Gbps2030Gbps10000entries(IPv4),5000entries(IPv6)64000entries
IPv6ReadyCertified<2.8µs(FIFO64-bytepackets)<1.8µs(FIFO64-bytepackets)<1.5µs(FIFO64-bytepackets)Upto571.4Mpps960Gbps1015Gbps10000entries(IPv4),5000entries(IPv6)64000entries
IPv6ReadyCertified<2.8µs(FIFO64-bytepackets)<1.8µs(FIFO64-bytepackets)<1.5µs(FIFO64-bytepackets)Upto1142.8Mpps1920Gbps2030Gbps10000entries(IPv4),5000entries(IPv6)64000entries
EnvironmentOperatingtemperature
OperatingrelativehumidityNonoperating/StoragetemperatureNonoperating/StoragerelativehumidityAltitudeAcoustic
32°Fto113°F(0°Cto45°C);0°Cto40°CwithJ8177Ctransceiverinstalled,0°Cto35°CwithFIPSOpacityShieldinstalled15%to95%@113°F(45°C),noncondensing-40°Fto158°F(-40°Cto70°C)15%to95%@149°F(65°C),noncondensingupto10,000ft(3km)Power:49dB,Pressure:35.7dBISO7779,ISO9296
32°Fto113°F(0°Cto45°C);0°Cto40°CwithJ8177Ctransceiverinstalled,0°Cto35°CwithFIPSOpacityShieldinstalled15%to95%@113°F(45°C),noncondensing-40°Fto158°F(-40°Cto70°C)15%to95%@149°F(65°C),noncondensingupto10,000ft(3km)Power:44dB,Pressure:31.7dBISO7779,ISO9296
32°Fto113°F(0°Cto45°C);0°Cto40°CwithJ8177Ctransceiverinstalled,0°Cto35°CwithFIPSOpacityShieldinstalled15%to95%@113°F(45°C),noncondensing-40°Fto158°F(-40°Cto70°C)15%to95%@149°F(65°C),noncondensingupto10,000ft(3km)Power:49dB,Pressure:35.7dBISO7779,ISO9296
ElectricalcharacteristicsFrequency80plus.orgCertificationDescription
Maximumheatdissipation
Voltage
Idlepower
Notes
50/60HzGoldDoesnotcomewithpowersupply.Fouropenpowersupplyslotsareavailable;threedifferentpowersuppliesareavailable.Seepowersupplyproductsforadditionalspecifications.4900BTU/hr(5169.5kJ/hr),(max.non-PoE);7400BTU/hr(7807kJ/hr),(max.usingPoE)110–127/200–240VAC,rated(dependingonpowersupplychosen)312WIdlepoweristheactualpowerconsumptionofthedevicewithnoportsconnected.
HeatdissipationdoesnotincludeheatdissipatedbythePoE-powereddevicesthemselves.Whenmorethanfourpowercordsareinstalledina5412Rzl2switchchassis,additionalinstallationrequirementsareneeded.RefertotheHPE5400Rzl2SwitchesQuickSetupGuideandSafety/RegulatoryInformationmanualfordetails.
50/60HzGoldDoesnotcomewithpowersupply.Twoopenpowersupplyslotsareavailable;threedifferentpowersuppliesareavailable.Seepowersupplyproductsforadditionalspecifications.2450BTU/hr(2584.75kJ/hr),(max.non-PoE);3700BTU/hr(3903kJ/hr),(max.usingPoE)110–127/200–240VAC,rated(dependingonpowersupplychosen)215WIdlepoweristheactualpowerconsumptionofthedevicewithnoportsconnected.
HeatdissipationdoesnotincludeheatdissipatedbythePoE-powereddevicesthemselves.
50/60HzGoldDoesnotcomewithpowersupply.Fouropenpowersupplyslotsareavailable;threedifferentpowersuppliesareavailable.Seepowersupplyproductsforadditionalspecifications.4900BTU/hr(5169.5kJ/hr),(max.non-PoE);7400BTU/hr(7807kJ/hr),(max.usingPoE)110–127/200–240VAC,rated(dependingonpowersupplychosen)312WIdlepoweristheactualpowerconsumptionofthedevicewithnoportsconnected.
HeatdissipationdoesnotincludeheatdissipatedbythePoE-powereddevicesthemselves.Whenmorethanfourpowercordsareinstalledina5412Rzl2switchchassis,additionalinstallationrequirementsareneeded.RefertotheHPE5400Rzl2SwitchesQuickSetupGuideandSafety/RegulatoryInformationmanualfordetails.
Page 17Data sheet
HPE 5412R-92G-PoE+/2SFP+ (No PSU) v2 zl2 Switch (J9825A)
HPE 5406R-44G-PoE+/4SFP (No PSU) v2 zl2 Switch (J9824A)
HPE 5412R-92G-PoE+/4SFP (No PSU) v2 zl2 Switch (J9826A)
Safety CSA22.2No.60950;UL60950;IEC60950;EN60950
CSA22.2No.60950;UL60950;IEC60950;EN60950
CSA22.2No.60950;UL60950;IEC60950;EN60950
Emissions FCCpart15ClassA;EN55022/CISPR22ClassA
FCCpart15ClassA;EN55022/CISPR22ClassA
FCCpart15ClassA;EN55022/CISPR22ClassA
ImmunityENESD
RadiatedEFT/Burst
SurgeConductedPowerfrequencymagneticfield
HarmonicsFlicker
EN55024,CISPR24IEC61000-4-2;4kVCD,8kVAD;HPEENV.765.002IEC61000-4-3;3V/mIEC61000-4-4;1.0kV(powerline),0.5kV(signalline)IEC61000-4-5;1kV/2kVAC,1kVsignal,0.5kVDCIEC61000-4-6;3VrmsIEC61000-4-8;1A/m,50or60HzIEC61000-4-11;>95%reduction,0.5period;30%reduction,25periodsEN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
EN55024,CISPR24IEC61000-4-2;4kVCD,8kVAD;HPEENV.765.002IEC61000-4-3;3V/mIEC61000-4-4;1.0kV(powerline),0.5kV(signalline)IEC61000-4-5;1kV/2kVAC,1kVsignal,0.5kVDCIEC61000-4-6;3VrmsIEC61000-4-8;1A/m,50or60HzIEC61000-4-11;>95%reduction,0.5period;30%reduction,25periodsEN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
EN55024,CISPR24IEC61000-4-2;4kVCD,8kVAD;HPEENV.765.002IEC61000-4-3;3V/mIEC61000-4-4;1.0kV(powerline),0.5kV(signalline)IEC61000-4-5;1kV/2kVAC,1kVsignal,0.5kVDCIEC61000-4-6;3VrmsIEC61000-4-8;1A/m,50or60HzIEC61000-4-11;>95%reduction,0.5period;30%reduction,25periodsEN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;Command-lineinterface;Webbrowser;Configurationmenu;Out-of-bandmanagement(RJ-45Ethernet);SNMPManager;Out-of-bandmanagement(serialRS-232CormicroUSB)AirWaveNetworkManagement
IMC—IntelligentManagementCenter;Command-lineinterface;Webbrowser;Configurationmenu;Out-of-bandmanagement(RJ-45Ethernet);SNMPManager;Out-of-bandmanagement(serialRS-232CormicroUSB)AirWaveNetworkManagement
IMC—IntelligentManagementCenter;Command-lineinterface;Webbrowser;Configurationmenu;Out-of-bandmanagement(RJ-45Ethernet);SNMPManager;Out-of-bandmanagement(serialRS-232CormicroUSB)AirWaveNetworkManagement
Notes Supported1GSFPtransceiversarerevision“B”orlater(productnumberendswiththeletter“B”orlater;Forexample,J9142B,J8177C).
Supported1GSFPtransceiversarerevision“B”orlater(productnumberendswiththeletter“B”orlater;Forexample,J9142B,J8177C).
Supported1GSFPtransceiversarerevision“B”orlater(productnumberendswiththeletter“B”orlater;Forexample,J9142B,J8177C).
Services RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
Page 18Data sheet
HPE 5400R zl2 Switch Series
Specifications (continued)
HPE 5406R-8XGT/8SFP+ (No PSU) v2 zl2 Switch (J9868A)
HPE 5412R 92GT PoE+/4SFP+ (No PSU) v3 zl2 Switch (JL001A)
HPE 5406R 8-port 1/2.5/5/10GBASE-T PoE+/8-port SFP+ (No PSU) v3 zl2 Switch (JL002A)
Includedaccessories 1HPE5400Rzl2ManagementModule(J9827A)1HPE5406Rzl2SwitchFanTray(J9831A)1HPE8-port10GbESFP+v2zlModule(J9538A)1HPE8-port10GBASE-Tv2zlModule(J9546A)
1HPE5400Rzl2ManagementModule(J9827A)1HPE5412Rzl2SwitchFanTray(J9832A)3HPE24-port10/100/1000BASE-TPoE+MACsecv3zl2Module(J9986A)1HPE20-port10/100/1000BASE-TPoE+/4-port1G/10GbESFP+MACsecv3zl2Module(J9990A)
1HPE5400Rzl2ManagementModule(J9827A)1HPE5406Rzl2SwitchFanTray(J9831A)1HPE8-port1G/10GbESFP+MACsecv3zl2Module(J9993A)1HPE8-port1/2.5/5/10GBASE-TPoE+MACsecv3zl2Module(J9995A)
I/Oportsandslots 8RJ-4510GbEports(IEEE802.3an-2006Type10GBASE-T)8open10GbESFP+transceiverslots4openmoduleslotsSupportsamaximumof144autosensing10/100/1000portsor144SFPportsor48SFP+portsor48HPESmartRateMulti-Gigabitor1240GbEports,oracombination
92RJ-45autosensing10/100/1000PoE+ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T,IEEE802.3atPoE+);MediaType:Auto-MDIX;Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly4open10GbESFP+transceiverslots8openmoduleslotsSupportsamaximumof288autosensing10/100/1000portsor288SFPportsor96SFP+portsor96HPESmartRateMulti-Gigabitor2440GbEports,oracombination
8RJ-45HPESmartRateMulti-Gigabitports8open10GbESFP+transceiverslots4openmoduleslotsSupportsamaximumof144autosensing10/100/1000portsor144SFPportsor48SFP+portsor48HPESmartRateMulti-Gigabitor1240GbEports,oracombination
Powersupplies 2powersupplyslots1minimumpowersupplyrequired(orderedseparately)
4powersupplyslots2minimumpowersuppliesrequired(orderedseparately)
2powersupplyslots1minimumpowersupplyrequired(orderedseparately)
Fantray Includes:1xJ9831A1fantrayslot
Includes:1xJ9832A1fantrayslot
Includes:1xJ9831A1fantrayslot
PhysicalcharacteristicsDimensions
Weight
17.5(w)x17.75(d)x6.9(h)in.(44.45x45.09x17.53cm)(4Uheight)28.11lb(12.75kg)
17.5(w)x17.75(d)x12.1(h)in.(44.45x45.09x30.73cm)(7Uheight)45.19lb(20.5kg)
17.5(w)x17.75(d)x6.9(h)in.(44.45x45.09x17.53cm)(4Uheight)28.11lb(12.75kg)
Memoryandprocessorv3GigabitModule
v2GigabitModule
v310GModule
v210GModule
v340GModule
ManagementModule
DualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@450MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@550MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:[email protected],16MBflash,1GBSDCard,4GBDDR3SODIMM
DualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@450MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@550MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:[email protected],16MBflash,1GBSDCard,4GBDDR3SODIMM
DualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@450MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@550MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:[email protected],16MBflash,1GBSDCard,4GBDDR3SODIMM
Page 19Data sheet
HPE 5406R-8XGT/8SFP+ (No PSU) v2 zl2 Switch (J9868A)
HPE 5412R 92GT PoE+/4SFP+ (No PSU) v3 zl2 Switch (JL001A)
HPE 5406R 8-port 1/2.5/5/10GBASE-T PoE+/8-port SFP+ (No PSU) v3 zl2 Switch (JL002A)
Mountingandenclosure MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded);Horizontalsurfacemountingonly
MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded);Horizontalsurfacemountingonly
MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded);Horizontalsurfacemountingonly
Performance1000MbLatency10GbpsLatency40GbpsLatencyThroughputRouting/SwitchingcapacitySwitchfabricspeedRoutingtablesizeMACaddresstablesize
IPv6ReadyCertified<2.8µs(FIFO64-bytepackets)<1.8µs(FIFO64-bytepackets)<1.5µs(FIFO64-bytepackets)upto571.4Mpps960Gbps1015Gbps10000entries(IPv4),5000entries(IPv6)64000entries
<2.8µs(FIFO64-bytepackets)<1.8µs(FIFO64-bytepackets)<1.5µs(FIFO64-bytepackets)upto1142.8Mpps1920Gbps2030Gbps10000entries(IPv4),5000entries(IPv6)64000entries
<2.8µs(FIFO64-bytepackets)<1.8µs(FIFO64-bytepackets)<1.5µs(FIFO64-bytepackets)upto571.4Mpps960Gbps1015Gbps10000entries(IPv4),5000entries(IPv6)64000entries
EnvironmentOperatingtemperature
OperatingrelativehumidityNonoperating/StoragetemperatureNonoperating/StoragerelativehumidityAltitudeAcoustic
32°Fto113°F(0°Cto45°C);0°Cto40°CwithJ8177Ctransceiverinstalled,0°Cto35°CwithFIPSOpacityShieldinstalled15%to95%@113°F(45°C),noncondensing-40°Fto158°F(-40°Cto70°C)15%to95%@149°F(65°C),noncondensingUpto10,000ft(3km)Power:44dB,Pressure:31.7dBISO7779,ISO9296
32°Fto113°F(0°Cto45°C);0°Cto40°CwithJ8177Ctransceiverinstalled,0°Cto35°CwithFIPSOpacityShieldinstalled15%to95%@113°F(45°C),noncondensing-40°Fto158°F(-40°Cto70°C)15%to95%@149°F(65°C),noncondensingUpto10,000ft(3km)Power:49dB,Pressure:35.7dBISO7779,ISO9296
32°Fto113°F(0°Cto45°C);0°Cto40°CwithJ8177Ctransceiverinstalled,0°Cto35°CwithFIPSOpacityShieldinstalled15%to95%@113°F(45°C),noncondensing-40°Fto158°F(-40°Cto70°C)15%to95%@149°F(65°C),noncondensingUpto10,000ft(3km)Power:44dB,Pressure:31.7dBISO7779,ISO9296
ElectricalcharacteristicsFrequency80plus.orgCertificationDescription
Maximumheatdissipation
Voltage
Idlepower
Notes
50/60HzGoldDoesnotcomewithpowersupply.Twoopenpowersupplyslotsareavailable;threedifferentpowersuppliesareavailable.Seepowersupplyproductsforadditionalspecifications.2450BTU/hr(2584.75kJ/hr),(max.non-PoE);3700BTU/hr(3903kJ/hr),(max.usingPoE)110–127/200–240VAC,rated(dependingonpowersupplychosen)215WIdlepoweristheactualpowerconsumptionofthedevicewithnoportsconnected.
HeatdissipationdoesnotincludeheatdissipatedbythePoE-powereddevicesthemselves.
50/60HzGoldDoesnotcomewithpowersupply.Fouropenpowersupplyslotsareavailable;threedifferentpowersuppliesareavailable.Seepowersupplyproductsforadditionalspecifications.4900BTU/hr(5169.5kJ/hr),(max.non-PoE);7400BTU/hr(7807kJ/hr),(max.usingPoE)110–127/200–240VAC,rated(dependingonpowersupplychosen)312WIdlepoweristheactualpowerconsumptionofthedevicewithnoportsconnected.
HeatdissipationdoesnotincludeheatdissipatedbythePoE-powereddevicesthemselves.Whenmorethanfourpowercordsareinstalledina5412Rzl2switchchassis,additionalinstallationrequirementsareneeded.RefertotheHPE5400Rzl2SwitchesQuickSetupGuideandSafety/RegulatoryInformationmanualfordetails.
50/60HzGoldDoesnotcomewithpowersupply.Twoopenpowersupplyslotsareavailable;threedifferentpowersuppliesareavailable.Seepowersupplyproductsforadditionalspecifications.2450BTU/hr(2584.75kJ/hr),(max.non-PoE);3700BTU/hr(3903kJ/hr),(max.usingPoE)110–127/200–240VAC,rated(dependingonpowersupplychosen)215WIdlepoweristheactualpowerconsumptionofthedevicewithnoportsconnected.HeatdissipationdoesnotincludeheatdissipatedbythePoE-powereddevicesthemselves.
Page 20Data sheet
HPE 5406R-8XGT/8SFP+ (No PSU) v2 zl2 Switch (J9868A)
HPE 5412R 92GT PoE+/4SFP+ (No PSU) v3 zl2 Switch (JL001A)
HPE 5406R 8-port 1/2.5/5/10GBASE-T PoE+/8-port SFP+ (No PSU) v3 zl2 Switch (JL002A)
Safety CSA22.2No.60950;UL60950;IEC60950;EN60950
CSA22.2No.60950;UL60950;IEC60950;EN60950
CSA22.2No.60950;UL60950;IEC60950;EN60950
Emissions FCCpart15ClassA;EN55022/CISPR22ClassA
FCCpart15ClassA;EN55022/CISPR22ClassA
FCCpart15ClassA;EN55022/CISPR22ClassA
ImmunityENESD
RadiatedEFT/Burst
SurgeConductedPowerfrequencymagneticfield
HarmonicsFlicker
EN55024,CISPR24IEC61000-4-2;4kVCD,8kVAD;HPEENV.765.002IEC61000-4-3;3V/mIEC61000-4-4;1.0kV(powerline),0.5kV(signalline)IEC61000-4-5;1kV/2kVAC,1kVsignal,0.5kVDCIEC61000-4-6;3VrmsIEC61000-4-8;1A/m,50or60HzIEC61000-4-11;>95%reduction,0.5period;30%reduction,25periodsEN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
EN55024,CISPR24IEC61000-4-2;4kVCD,8kVAD;HPEENV.765.002IEC61000-4-3;3V/mIEC61000-4-4;1.0kV(powerline),0.5kV(signalline)IEC61000-4-5;1kV/2kVAC,1kVsignal,0.5kVDCIEC61000-4-6;3VrmsIEC61000-4-8;1A/m,50or60HzIEC61000-4-11;>95%reduction,0.5period;30%reduction,25periodsEN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
EN55024,CISPR24IEC61000-4-2;4kVCD,8kVAD;HPEENV.765.002IEC61000-4-3;3V/mIEC61000-4-4;1.0kV(powerline),0.5kV(signalline)IEC61000-4-5;1kV/2kVAC,1kVsignal,0.5kVDCIEC61000-4-6;3VrmsIEC61000-4-8;1A/m,50or60HzIEC61000-4-11;>95%reduction,0.5period;30%reduction,25periodsEN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;Command-lineinterface;Webbrowser;Configurationmenu;Out-of-bandmanagement(RJ-45Ethernet);SNMPManager;Out-of-bandmanagement(serialRS-232CormicroUSB)AirWaveNetworkManagement
IMC—IntelligentManagementCenter;Command-lineinterface;Webbrowser;Configurationmenu;Out-of-bandmanagement(RJ-45Ethernet);SNMPManager;Out-of-bandmanagement(serialRS-232CormicroUSB)AirWaveNetworkManagement
IMC—IntelligentManagementCenter;Command-lineinterface;Webbrowser;Configurationmenu;Out-of-bandmanagement(RJ-45Ethernet);SNMPManager;Out-of-bandmanagement(serialRS-232CormicroUSB)AirWaveNetworkManagement
Notes Supported1GSFPtransceiversarerevision“B”orlater(productnumberendswiththeletter“B”orlater;Forexample,J9142B,J8177C).
Supported1GSFPtransceiversarerevision“B”orlater(productnumberendswiththeletter“B”orlater;Forexample,J9142B,J8177C).
Supported1GSFPtransceiversarerevision“B”orlater(productnumberendswiththeletter“B”orlater;Forexample,J9142B,J8177C).HPESmartRateMulti-GigabitCabling;1000BASE-T,2.5Gigabit,and5GigabitEthernet:Category5eorbetterUTPorSTP;10GBASE-T:Category6orbetter(CAT6Arecommended)UTPorSTP
Services RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
Page 21Data sheet
HPE 5400R zl2 Switch Series
Specifications (continued)
HPE 5406R 44GT PoE+/4SFP+ (No PSU) v3 zl2 Switch (JL003A)
HPE 5406R 16-port SFP+ (No PSU) v3 zl2 Switch (JL095A)
Includedaccessories 1HPE5400Rzl2ManagementModule(J9827A)1HPE5406Rzl2SwitchFanTray(J9831A)1HPE24-port10/100/1000BASE-TPoE+MACsecv3zl2Module(J9986A)1HPE20-port10/100/1000BASE-TPoE+/4-port1G/10GbESFP+MACsecv3zl2Module(J9990A)
1HPE5400Rzl2ManagementModule(J9827A)1HPE5406Rzl2SwitchFanTray(J9831A)2HPE8-port1G/10GbESFP+MACsecv3zl2Module(J9993A)
I/Oportsandslots 44RJ-45autosensing10/100/1000PoE+ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T,IEEE802.3atPoE+);MediaType:Auto-MDIX;Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly4open10GbESFP+transceiverslots4openmoduleslotsSupportsamaximumof144autosensing10/100/1000portsor144SFPportsor48SFP+portsor48HPESmartRateMulti-Gigabitor1240GbEports,oracombination
16open10GbESFP+transceiverslots4openmoduleslotsSupportsamaximumof144autosensing10/100/1000portsor144SFPportsor48SFP+portsor48HPESmartRateMulti-Gigabitor1240GbEports,oracombination
Powersupplies 2powersupplyslots1minimumpowersupplyrequired(orderedseparately)
2powersupplyslots1minimumpowersupplyrequired(orderedseparately)
Fantray Includes:1xJ9831A1fantrayslot
Includes:1xJ9831A1fantrayslot
PhysicalcharacteristicsDimensions
Weight
17.5(w)x17.75(d)x6.9(h)in.(44.45x45.09x17.53cm)(4Uheight)28.11lb(12.75kg)
17.5(w)x17.75(d)x6.9(h)in.(44.45x45.09x17.53cm)(4Uheight)28.11lb(12.75kg)
Memoryandprocessorv3GigabitModule
v2GigabitModulev310GModule
v210GModulev340GModule
ManagementModule
DualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@450MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@550MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:[email protected],16MBflash,1GBSDCard,4GBDDR3SODIMM
DualARMCoretexA9@1GHz;Packetbuffersize:13.5MBinternalARM11@450MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1;Packetbuffersize:13.5MBinternalARM11@550MHz;Packetbuffersize:18MBinternalDualARMCoretexA9@1GHz;Packetbuffersize:[email protected],16MBflash,1GBSDCard,4GBDDR3SODIMM
Mountingandenclosure MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded);Horizontalsurfacemountingonly
MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded);Horizontalsurfacemountingonly
Page 22Data sheet
HPE 5406R 44GT PoE+/4SFP+ (No PSU) v3 zl2 Switch (JL003A)
HPE 5406R 16-port SFP+ (No PSU) v3 zl2 Switch (JL095A)
Performance1000MbLatency10GbpsLatency40GbpsLatencyThroughputRouting/SwitchingcapacitySwitchfabricspeedRoutingtablesizeMACaddresstablesize
<2.8µs(FIFO64-bytepackets)<1.8µs(FIFO64-bytepackets)<1.5µs(FIFO64-bytepackets)upto571.4Mpps960Gbps1015Gbps10000entries(IPv4),5000entries(IPv6)64000entries
<2.8µs(FIFO64-bytepackets)<1.8µs(FIFO64-bytepackets)<1.5µs(FIFO64-bytepackets)upto571.4Mpps960Gbps1015Gbps10000entries(IPv4),5000entries(IPv6)64000entries
EnvironmentOperatingtemperature
OperatingrelativehumidityNonoperating/StoragetemperatureNonoperating/StoragerelativehumidityAltitudeAcoustic
32°Fto113°F(0°Cto45°C);0°Cto40°CwithJ8177Ctransceiverinstalled,0°Cto35°CwithFIPSOpacityShieldinstalled15%to95%@113°F(45°C),noncondensing-40°Fto158°F(-40°Cto70°C)15%to95%@149°F(65°C),noncondensingUpto10,000ft(3km)Power:44dB,Pressure:31.7dBISO7779,ISO9296
32°Fto113°F(0°Cto45°C);0°Cto40°CwithJ8177Ctransceiverinstalled,0°Cto35°CwithFIPSOpacityShieldinstalled15%to95%@113°F(45°C),noncondensing-40°Fto158°F(-40°Cto70°C)15%to95%@149°F(65°C),noncondensingUpto10,000ft(3km)Power:44dB,Pressure:31.7dBISO7779,ISO9296
ElectricalcharacteristicsFrequency80plus.orgCertificationDescription
Maximumheatdissipation
Voltage
Idlepower
Notes
50/60HzGoldDoesnotcomewithpowersupply.Twoopenpowersupplyslotsareavailable;threedifferentpowersuppliesareavailable.Seepowersupplyproductsforadditionalspecifications.2450BTU/hr(2584.75kJ/hr),(max.non-PoE);3700BTU/hr(3903kJ/hr),(max.usingPoE)110–127/200–240VAC,rated(dependingonpowersupplychosen)215WIdlepoweristheactualpowerconsumptionofthedevicewithnoportsconnected.
HeatdissipationdoesnotincludeheatdissipatedbythePoE-powereddevicesthemselves.
50/60HzGoldDoesnotcomewithpowersupply.Twoopenpowersupplyslotsareavailable;threedifferentpowersuppliesareavailable.Seepowersupplyproductsforadditionalspecifications.2450BTU/hr(2584.75kJ/hr),(max.non-PoE);3700BTU/hr(3903kJ/hr),(max.usingPoE)110–127/200–240VAC,rated(dependingonpowersupplychosen)215WIdlepoweristheactualpowerconsumptionofthedevicewithnoportsconnected.
HeatdissipationdoesnotincludeheatdissipatedbythePoE-powereddevicesthemselves.
Page 23Data sheet
HPE 5406R 44GT PoE+/4SFP+ (No PSU) v3 zl2 Switch (JL003A)
HPE 5406R 16-port SFP+ (No PSU) v3 zl2 Switch (JL095A)
Safety CSA22.2No.60950;UL60950;IEC60950;EN60950 CSA22.2No.60950;UL60950;IEC60950;EN60950
Emissions FCCpart15ClassA;EN55022/CISPR22ClassA FCCpart15ClassA;EN55022/CISPR22ClassA
ImmunityENESDRadiatedEFT/BurstSurgeConductedPowerfrequencymagneticfieldVoltagedipsandinterruptions
HarmonicsFlicker
EN55024,CISPR24IEC61000-4-2;4kVCD,8kVAD;HPEENV.765.002IEC61000-4-3;3V/mIEC61000-4-4;1.0kV(powerline),0.5kV(signalline)IEC61000-4-5;1kV/2kVAC,1kVsignal,0.5kVDCIEC61000-4-6;3VrmsIEC61000-4-8;1A/m,50or60HzIEC61000-4-11;>95%reduction,0.5period;30%reduction,25periodsEN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
EN55024,CISPR24IEC61000-4-2;4kVCD,8kVAD;HPEENV.765.002IEC61000-4-3;3V/mIEC61000-4-4;1.0kV(powerline),0.5kV(signalline)IEC61000-4-5;1kV/2kVAC,1kVsignal,0.5kVDCIEC61000-4-6;3VrmsIEC61000-4-8;1A/m,50or60HzIEC61000-4-11;>95%reduction,0.5period;30%reduction,25periodsEN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
Management IMC–IntelligentManagementCenter;Command-lineinterface;Webbrowser;Configurationmenu;Out-of-bandmanagement(RJ-45Ethernet);SNMPManager;Out-of-bandmanagement(serialRS-232CormicroUSB)AirWaveNetworkManagement
IMC–IntelligentManagementCenter;Command-lineinterface;Webbrowser;Configurationmenu;Out-of-bandmanagement(RJ-45Ethernet);SNMPManager;Out-of-bandmanagement(serialRS-232CormicroUSB)AirWaveNetworkManagement
Notes Supported1GSFPtransceiversarerevision“B”orlater(productnumberendswiththeletter“B”orlater;Forexample,J9142B,J8177C).
Supported1GSFPtransceiversarerevision“B”orlater(productnumberendswiththeletter“B”orlater;Forexample,J9142B,J8177C).
Services RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
Page 24Data sheet
Standards and Protocols(appliestoallproductsinseries)
BGP RFC1997BGPCommunitiesAttributeRFC2918RouteRefreshCapabilityRFC4271ABorderGatewayProtocol4(BGP-4)
RFC4456BGPRouteReflection:AnAlternativetoFullMeshInternalBGP(IBGP)
RFC5492CapabilitiesAdvertisementwithBGP-4
Devicemanagement RFC1591DNS(client) HTMLandtelnetmanagement RFC2576(CoexistencebetweenSNMPV1,V2,V3)RFC2579(SMIv2TextConventions)RFC2580(SMIv2Conformance)RFC3416(SNMPProtocolOperationsv2)RFC3417(SNMPTransportMappings)
Generalprotocols IEEE802.1adQ-in-QIEEE802.1AX-2008LinkAggregationIEEE802.1DMACBridgesIEEE802.1pPriorityIEEE802.1QVLANsIEEE802.1sMultipleSpanningTreesIEEE802.1vVLANclassificationbyProtocolandPortIEEE802.1wRapidReconfigurationofSpanningTreeIEEE802.3adLinkAggregationControlProtocol(LACP)IEEE802.3afPoweroverEthernetIEEE802.3xFlowControl
RFC768UDPRFC783TFTPProtocol(revision2)RFC792ICMPRFC793TCPRFC826ARPRFC854TELNETRFC868TimeProtocolRFC951BOOTPRFC1058RIPv1RFC1350TFTPProtocol(revision2)RFC1519CIDR
RFC1542BOOTPExtensionsRFC1918AddressAllocationforPrivateInternetRFC2030SimpleNetworkTimeProtocol(SNTP)v4RFC2131DHCPRFC2453RIPv2RFC2548(MS-RAS-Vendoronly)RFC3046DHCPRelayAgentInformationOptionRFC3575IANAConsiderationsforRADIUSRFC3576ExttoRADIUS(CoAonly)RFC3768VRRPRFC4675RADIUSVLAN&PriorityUDLD(Uni-DirectionalLinkDetection)RFC5880BFDRFC5905NTPClient
IPmulticast RFC3376IGMPv3 RFC3973PIMDenseMode RFC4601PIMSparseMode
IPv6 RFC1981IPv6PathMTUDiscoveryRFC2375IPv6MulticastAddressRFC2080RIPngRFC2081RIPngProtocolApplicabilityRFC2082RIP-2MD5AssignmentsRFC2460IPv6SpecificationRFC2464TransmissionofIPv6overEthernetNetworksRFC2710MulticastListenerDiscovery(MLD)forIPv6RFC2925DefinitionsofManagedObjectsforRemotePing,Traceroute,andLookupOperations(Pingonly)RFC3019MLDv1MIBRFC3315DHCPv6(clientandrelay)RFC3484DefaultAddressSelectionforIPv6
RFC3587IPv6GlobalUnicastAddressFormatRFC3596DNSExtensionforIPv6RFC3810MLDv2forIPv6RFC4022MIBforTCPRFC4087IPTunnelMIBRFC4113MIBforUDPRFC4213BasicTransitionMechanismsforIPv6HostsandRoutersRFC4251SSHv6ArchitectureRFC4252SSHv6AuthenticationRFC4253SSHv6TransportLayerRFC4254SSHv6ConnectionRFC4291IPVersion6AddressingArchitectureRFC4293MIBforIP
RFC4294IPv6NodeRequirementsRFC4419KeyExchangeforSSHRFC4443ICMPv6RFC4541IGMP&MLDSnoopingSwitchRFC4861IPv6NeighborDiscoveryRFC4862IPv6StatelessAddressAuto-configurationRFC5095DeprecationofType0RoutingHeadersinIPv6RFC5340OSPFv3forIPv6RFC5453ReservedIPv6InterfaceIdentifiersRFC5519MulticastGroupMembershipDiscoveryMIB(MLDv2only)RFC5722HandlingofOverlappingIPv6FragmentsRFC6620FCFSSAVIdraft-ietf-savi-mix
Page 25Data sheet
Standards and Protocols (continued) (appliestoallproductsinseries)
MIBs IEEE802.1ap(MSTPandSTPMIB’sonly)IEEE8021-Bridge-MIB(2008)IEEE8021-Q-Bridge-MIB(2008)RFC1155Structure&IDofMgmtInfoforTCP/IPInternetsRFC1213MIBIIRFC1493BridgeMIBRFC1724RIPv2MIBRFC1850OSPFv2MIBRFC2021RMONv2MIBRFC2096IPForwardingTableMIB
RFC2578StructureofManagementInformationVersion2(SMIv2)RFC2613SMONMIBRFC2618RADIUSClientMIBRFC2620RADIUSAccountingMIBRFC2665Ethernet-Like-MIBRFC2668802.3MAUMIBRFC2674802.1pandIEEE802.1QBridgeMIBRFC2737EntityMIB(Version2)
RFC2787VRRPMIBRFC2863TheInterfacesGroupMIBRFC2925PingMIBRFC2932IP(MulticastRoutingMIB)RFC2933IGMPMIBRFC4292IPForwardingTableMIBRFC4836ManagedObjectsfor802.3MediumAttachmentUnits(MAU)RFC7331BFDMIB
Networkmanagement IEEE802.1ABLinkLayerDiscoveryProtocol(LLDP)RFC2819FourgroupsofRMON:1(statistics),2(history),3(alarm),and9(events)
RFC3176sFlowRFC3411SNMPManagementFrameworksRFC3412MessageProcessingandDispatchingfortheSimpleNetworkManagementProtocol(SNMP)RFC3413SimpleNetworkManagementProtocol(SNMP)ApplicationsRFC3414User-basedSecurityModel(USM)forversion3oftheSimpleNetworkManagementProtocol(SNMPv3)RFC3415View-basedAccessControlModel(VACM)fortheSimpleNetworkManagementProtocol(SNMP)RFC3418ManagementInformationBase(MIB)fortheSimpleNetworkManagementProtocol(SNMP)RFC5424SyslogProtocolANSI/TIA-1057LLDPMediaEndpointDiscovery(LLDP-MED)
SNMPv1/v2c/v3XRMON
OSPF RFC2328OSPFv2 RFC3101OSPFNSSA RFC5340OSPFv3forIPv6
QoS/CoS RFC2474DiffServPrecedence,including8queues/portRFC2475DiffServArchitecture
RFC2597DiffServAssuredForwarding(AF) RFC2598DiffServExpeditedForwarding(EF)
Security IEEE802.1AEMACSecurityStandard(MACsec)IEEE802.1XPortBasedNetworkAccessControlRFC1492TACACS+
RFC1321TheMD5Message-DigestAlgorithmRFC2818HTTPOverTLSRFC2865RADIUS(clientonly)RFC2866RADIUSAccountingRFC3579RADIUSSupportForExtensibleAuthenticationProtocol(EAP)
SecureSocketsLayer(SSL)SSHv2SecureShell
Page 26Data sheet
Modules HPE8-port1/2.5/5/10GBASE-TPoE+MACsecv3zl2Module(J9995A)HPE8-port10GBASE-Tv2zlModule(J9546A)HPE8-port1G/10GbESFP+MACsecv3zl2Module(J9993A)HPE8-port10GbESFP+v2zlModule(J9538A)HPE12-port10/100/1000BASE-TPoE+/12-port1GbESFPMACsecv3zl2Module(J9989A)HPE12-portGig-TPoE+/12-portSFPv2zlModule(J9637A)HPE20-portGig-T/4-portSFPv2zlModule(J9549A)HPE20-portGig-T/2-port10GbESFP+v2zlModule(J9548A)HPE20-port10/100/1000BASE-TPoE+/4-port1G/10GbESFP+MACsecv3zl2Module(J9990A)HPE20-portGig-TPoE+/2-port10GbESFP+v2zlModule(J9536A)HPE20-portGig-TPoE+/4-portSFPv2zlModule(J9535A)HPE20-port10/100/1000BASE-TPoE+/4p1/2.5/5/10GBASE-TPoE+MACsecv3zl2Module(J9991A)HPE20-port10/100/1000BASE-TPoE+MACsec/1-port40GbEQSFP+v3zl2Module(J9992A)HPE24-port10/100PoE+v2zlModule(J9547A)HPE24-port10/100/1000BASE-TMACsecv3zl2Module(J9987A)HPE24-portGig-Tv2zlModule(J9550A)HPE24-port10/100/1000BASE-TPoE+MACsecv3zl2Module(J9986A)HPE24-portGig-TPoE+v2zlModule(J9534A)HPE24-port1GbESFPMACsecv3zl2Module(J9988A)HPE24-portSFPv2zlModule(J9537A)HPE2-port40GbEQSFP+v3zl2Module(J9996A)HPEAdvancedServicesv2zlModulewithHDD(J9857A)HPEAdvancedServicesv2zlModulewithSSD(J9858A)HPE5400Rzl2ManagementModule(J9827A)
Transceivers HPEX111100MSFPLCFXTransceiver(J9054C)HPEX13110GX2SCLRTransceiver(J8437A)HPEX13210GSFP+LCSRTransceiver(J9150A)HPEX13210GSFP+LCLRTransceiver(J9151A)HPEX13210GSFP+LCLRMTransceiver(J9152A)HPEX1211GSFPLCLHTransceiver(J4860C)HPEX1211GSFPLCSXTransceiver(J4858C)HPEX1211GSFPLCLXTransceiver(J4859C)HPEX1211GSFPRJ45TTransceiver(J8177C)HPEX1221GSFPLCBX-DTransceiver(J9142B)HPEX1221GSFPLCBX-UTransceiver(J9143B)HPEX13210GSFP+LCERTransceiver(J9153A)HPEX14240GQSFP+MPOSR4Transceiver(JH231A)HPEX14240GQSFP+LCLR4SMTransceiver(JH232A)HPEX14240GQSFP+MPOeSR4300MXCVR(JH233A)
HPE 5400R zl2 Switch Series accessories
Page 27Data sheet
Cables HPEX24210GSFP+toSFP+1mDirectAttachCopperCable(J9281B)HPEX24210GSFP+toSFP+3mDirectAttachCopperCable(J9283B)HPEX24210GSFP+toSFP+7mDirectAttachCopperCable(J9285B)HPEX24410GXFPtoSFP+1mDirectAttachCopperCable(J9300A)HPEX24410GXFPtoSFP+3mDirectAttachCopperCable(J9301A)HPEX24410GXFPtoSFP+5mDirectAttachCopperCable(J9302A)HPE0.5mMultimodeOM3LC/LCOpticalCable(AJ833A)HPE1mMultimodeOM3LC/LCOpticalCable(AJ834A)HPE2mMultimodeOM3LC/LCOpticalCable(AJ835A)HPE5mMultimodeOM3LC/LCOpticalCable(AJ836A)HPE15mMultimodeOM3LC/LCOpticalCable(AJ837A)HPE30mMultimodeOM3LC/LCOpticalCable(AJ838A)HPE50mMultimodeOM3LC/LCOpticalCable(AJ839A)HPEPremierFlexLC/LCMulti-modeOM42fiber1mCable(QK732A)HPEPremierFlexLC/LCMulti-modeOM42fiber2mCable(QK733A)HPEPremierFlexLC/LCMulti-modeOM42fiber5mCable(QK734A)HPEPremierFlexLC/LCMulti-modeOM42fiber15mCable(QK735A)HPEPremierFlexLC/LCMulti-modeOM42fiber30mCable(QK736A)HPEPremierFlexLC/LCMulti-modeOM42fiber50mCable(QK737A)HPEX24240GQSFP+toQSFP+1mDACCable(JH234A)HPEX24240GQSFP+toQSFP+3mDACCable(JH235A)HPEX24240GQSFP+toQSFP+5mDACCable(JH236A)
Powersupply HPE5400R700WPoE+zl2PowerSupply(J9828A)HPE5400R1100WPoE+zl2PowerSupply(J9829A)HPE5400R2750WPoE+zl2PowerSupply(J9830A)
Mountingkit HPEX4504U/7UUniversal4-PostRackMountingKit(J9852A)
WLAN HPEMSM775zlPremiumControllerModule(J9840A)
Learnmoreathpe.com/networking
HPE 5400R zl2 Switch Series accessories (continued)
Ratethisdocument
Sign up for updates
Data sheet
©Copyright2014–2016HewlettPackardEnterpriseDevelopmentLP.Theinformationcontainedhereinissubjecttochangewithoutnotice.TheonlywarrantiesforHewlettPackardEnterpriseproductsandservicesaresetforthintheexpresswarrantystatementsaccompanyingsuchproductsandservices.Nothinghereinshouldbeconstruedasconstitutinganadditionalwarranty.HewlettPackardEnterpriseshallnotbeliablefortechnicaloreditorialerrorsoromissionscontainedherein.
ARMisaregisteredtrademarkofARMLimited.SDisatrademarkorregisteredtrademarkofSD-3CintheUnitedStatesandothercountriesorboth.sFlowisaregisteredtrademarkofInMonCorp.
4AA5-2605ENW,June2016,Rev.5