Welcome to the world of
Catalytic Converter Measurement Wafer Edge Profile Measurement Vacuum Testing Plant Engineering Network Engineering KoCoS Training
Switchgear Testing Resistance Measurement Protection Relay Testing Meter Testing Digital Fault Recording Power Quality Analysis Power Sources
![Page 2: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/2.jpg)
High-End Portable Relay Testing
The relay test systems of the ARTES II generation use innovative technology to meet all your test requirements, however complex they may be.
ARTES – PROTECTION RELAY TESTING
![Page 3: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/3.jpg)
ARTES 440 IIARTES 330 II
ARTES 300 II
ARTES 100
Three-phase systems
6 current outputs3 current outputs
Single-phase system
ARTES 460
ARTES – SYSTEMS OVERVIEW
![Page 4: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/4.jpg)
Microprocessor-controlled
Fully automatic regulation of output values
Local and software operation
High output power up to 1500 VA
Unlimited output duration without cooling phases
ARTES 100 – SYSTEM OVERVIEW
ARTES 100
Specifications
![Page 5: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/5.jpg)
Can test:Digital, static, electromechanical, self-powered protection relays without additional amplifiers
Overcurrent, overvoltage and undervoltage, overfrequency and underfrequency…
2 voltage outputs - 0 to 300 V / 300 VA - DC – AUX Output - as current channels 0 to 3 A / 300VA
Current output max. 250 A / 1000 VA - 0 to 10 A / 90 V - 0 to 40 A / 25 V - 0 to 100 A / 10 V - as voltage channel 0 to 90 V AC
2 analog inputs - 1 x U 0 to +/-10 V or +/- 600 V - 1 x I 0 to +/-20 mA or +/- 16 A
Measurement U, I, f, φ, S, P, Q, Z, R, X
4 binary inputs - 2 Groups / Wet / Dry
2 binary outputs
Power supply - 115 / 230 VAC / 47 to 63 Hz - 110 / 220 VDC
Weight: 18 kg
ARTES 100 – SYSTEM OVERVIEW
Specifications
Frequency
40 – 200 Hz
Phase angle
0° - 360°
![Page 6: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/6.jpg)
Ergonomic and easy to operate
Runs on a standard Windows PC
Automatic documentation
Standard scope of delivery
ARTES 100 – SOFTWARE „ARTES GO“
![Page 7: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/7.jpg)
ARTES 100 – STANDARD SCOPE OF DELIVERY
![Page 8: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/8.jpg)
ARTES 330 II
ARTES 300 II
with 3 current outputs
ARTES – THREE- PHASE SYSTEMS
![Page 9: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/9.jpg)
3 voltage outputs - 3 x 0 to 300 V / 75 VA - 1 x 0 to 600 V / 150 VA
3 current outputs - 3 x 0 to 25 A / 80 VA
10 low-level outputs - 10 x 0 to 10 Vs
2 analog inputs - 1 x 0 to ±10 V - 1 x 0 to ± 20 mA
8 binary inputs - wet / dry
2 binary outputs
Auxiliary DC output (option) - 12 to 260 V, 50 Watt
Weight: 10 kg
ARTES 300 II – SYSTEM OVERVIEW
Specifications
Can test:Digital, static protection relays without additional devices
All kinds of protection: overcurrent; overvoltage and undervoltage; overfrequency and underfrequency; distance ….
ARTES 300 II
![Page 10: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/10.jpg)
ARTES 330 II – SYSTEM OVERVIEW
3 voltage outputs - 3 x 0 to 300 V / 75 VA - 1 x 0 to 600 V / 150 VA
3 current outputs - 3 x 0 to 25 A / 200 VA - 1 x 0 to 75 A / 600 VA
10 low-level outputs - 10 x 0 to 10 Vs
2 analog inputs - 1 x 0 to ±10 V - 1 x 0 to ± 20 mA
8 binary inputs - wet / dry
2 binary outputs
Auxiliary DC output - 12 to 260 V, 50 Watt
Weight: 15 kg
Specifications
Can test:All types of relay: digital, static , electromechanical,self-powered protection relays without additional amplifiers
All kinds of protection: overcurrent; overvoltage and undervoltage; overfrequency and underfrequency; distance ….
ARTES 330 II
![Page 11: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/11.jpg)
ARTES 440 II
ARTES 460
with 6 current outputs
ARTES – THREE- PHASE SYSTEMS
![Page 12: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/12.jpg)
4 voltage outputs - 4 x 0 to 300 V / 75 VA - 1 x 0 to 600 V / 150 VA
6 current outputs - 6 x 0 to 16 A / 40 VA - 3 x 0 to 32 A / 80 VA
10 low-level outputs - 10 x 0 to 10 Vs
8 analog inputs - 4 x 0 to ±10 V / 600 V - 4 x 0 to ±20 mA / 10 V
8 binary inputs - wet / dry
2 binary outputs - 0 to 250 V / 8 A AC - 0 to 300 V / 8 A DC
Auxiliary DC output - 12 to 260 V, 50 Watt
Weight: 10 kg
ARTES 460 – SYSTEM OVERVIEW
Specifications
Can test:Digital, static protection relays without additional amplifiers
All kinds of protection: overcurrent; overvoltage and undervoltage; overfrequency and underfrequency; distance; differential….
Frequency
DC – 4000 Hz
DIFF Protection
3 – phase
High
Accuracy
![Page 13: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/13.jpg)
ARTES 440II – SYSTEM OVERVIEW
4 voltage outputs - 4 x 0 to 300 V / 75 VA - 1 x 0 to 600 V / 150 VA
6 current outputs - 6 x 0 to 25 A / 100 VA - 3 x 0 to 50 A / 200 VA - 1 x 0 to 75 A / 600 VA
10 low-level outputs - 10 x 0 to 10 Vs
8 analog inputs - 4 x 0 to ±10 V - 4 x 0 to ±20 mA
24 binary inputs - wet / dry
4 binary outputs - 0 to 250 V / 8 A AC - 0 to 300 V / 8 A DC
Auxiliary DC output - 12 to 260 V, 50 Watt
Weight: 15 kg
Specifications
Can test:All types of relay: digital, static, electromechanical, self- powered protection relays without additional amplifiers
All kinds of protection: overcurrent; overvoltage and undervoltage; overfrequency and underfrequency;
distance; differential ….
High Power
Frequency
DC – 4000 Hz
DIFF Protection
3 - phase
![Page 14: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/14.jpg)
New testing software…
…for protection relays
Runs on a standard Windows PC
Compatible with Windows 7, Vista, XP
Ergonomic and easy to operate
Microsoft Fluent user interface
Dialog boxes with contextual help
Graphical display of connection schemes
Automatic and manual tests
Test of IEC 61850- compliant protection equipment
ASSET Management
ARTES V4 – SOFTWARE
![Page 15: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/15.jpg)
Multifunctional panel (ribbon)
Numerical area Graphical area
ARTES V4 – OVERVIEW
![Page 16: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/16.jpg)
Graphical display of connection schemes
Automatic connectors identification
Display of connection schemes Automatic mapping of channels Automatic connector identification Management of external documents
Management of external documents
ARTES V4 – OVERVIEW
Automatic mapping of channels
![Page 17: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/17.jpg)
Standard scope of delivery
All types of manual tests
No pre-settings
Ramp function
Detailed progress graph
VD-Monitor
ARTES V4 – BASIC SOFTWARE
![Page 18: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/18.jpg)
IT - Monitor
ARTES V4 – AUTOMATIC TESTS
Overcurrent protection relays
Thermal characteristics protection relays
Formula editor
ARC function
Search function for IDTML characteristic
![Page 19: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/19.jpg)
IMP - Monitor
ARTES V4 – AUTOMATIC TESTS
Distance protection relays All kinds of characteristics
Circle Polygon MHO Lens Propeller
ARC function Search function
![Page 20: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/20.jpg)
DIFF - Monitor
ARTES V4 – AUTOMATIC TESTS
Differential protection relays
Flexible creation of DIFF characteristic
Separate settings for harmonic characteristic (up to 32 harmonic)
Automatic testing of transformers with up to three windings
![Page 21: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/21.jpg)
PIC - Monitor
ARTES V4 – AUTOMATIC TESTS
Automatic testing of pick-up and drop-off values
All kinds of protection: Overcurrent Overvoltage and undervoltage Overfrequency and underfrequency Vector jump
Automatic calculation and evaluation of drop-off ratio
![Page 22: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/22.jpg)
SYNC - Monitor
ARTES V4 – AUTOMATIC TESTS
Automatic testing of synchronization devices
All kinds of values: Time of synchronizing Voltage Frequency Phase
![Page 23: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/23.jpg)
TD - Monitor
ARTES V4 – AUTOMATIC TESTS
Automatic testing of transducers
All kinds of transducers:Current Active powerVoltage Reactive powerFrequency Apparent powerPhase Power factors
All types of characteristics:Linear Bent Square
![Page 24: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/24.jpg)
TRANSIG - Monitor
ARTES V4 – AUTOMATIC TESTS
Replay of fault records / COMTRADE files
Replay of all kinds of signal waveforms
Unlimited output duration
![Page 25: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/25.jpg)
SIGNAL - Editor
ARTES V4 – AUTOMATIC TESTS
Creating of all possible signals waveforms
Overloading functions:Ramp ExponentialSine DCHarmonics (80) ImpulseExpression
![Page 26: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/26.jpg)
SmartSequencer
ARTES V4 – AUTOMATIC TESTS
Event-controlled test procedures
Different events:Time Binary signals States
States definition with different modules:VD-Monitor IT-MonitorIMP-Monitor DIFF-Monitor
Do-Loops
![Page 27: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/27.jpg)
Test object database
ARTES V4 – AUTOMATION
![Page 28: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/28.jpg)
Automatic evaluation in real time
ARTES V4 – EVALUATION
![Page 29: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/29.jpg)
Automatic documentation
Export / PDF / XLS / RTF / XML
ARTES V4 – DOCUMENTATION
![Page 30: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/30.jpg)
HARDWARE – KEY FEATURES
High output power up to 600 VA
Adjustable compliance voltage 5 - 30 Vpk
Three-phase current output up to 50 A
Can test all types protection relays without additional devices (electromechanical, self-powered relays)
Play-back of COMTRADE files via hardware
All inputs and outputs are isolated galvanically
All models feature a USB interface as standard
Compact and rugged design
Very quiet and light
![Page 31: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/31.jpg)
Well organized, ergonomic software
Compatible with Windows 7
Display and configuration with primary or secondary values
Graphical display of connection schemes
Automatic allocation of inputs and outputs
Automatic parameterization / RIO Import
Integration and management of external documents
Automatic documentation
SOFTWARE – KEY FEATURES
![Page 32: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/32.jpg)
Automatic generation of dynamic test procedures for
Overcurrent protection relays
Thermal functions of protection relays
Distance protection relays
Differential protection relays
Synchronization devices
Measuring transducers
Response of protective devices
Event-driven test sequences
Testing protective devices with transient signals
SOFTWARE – KEY FEATURES
![Page 33: ARTES - Relay Testing](https://reader031.fdocuments.in/reader031/viewer/2022012308/5462ce5ab1af9f92238b5142/html5/thumbnails/33.jpg)