armas - BENIZ TAJHIZ
Transcript of armas - BENIZ TAJHIZ
armas.com.tr
ARMAŞ A.Ş. was founded in 1998 to produce valves for potable water and agricultural irrigation systems. It has become one of the leader establishments of its sector in a short time thanks to ARMAŞ makes valves.
ARMAŞ A.Ş. has given high quality services with economical prices to his costumers in industry, potable water networks and agricultural irrigation systems by means of Hydraulic Control Valves, Automatic Filtration Systems, Gate Valves, Ball Valves, Strainers, Check Valves, Air Valves and Hydrants he produced. Our company who does not sacrifice quality in production has used ISO 9001-2000 Quality Management System since 2000. In the scope of importance we gave for both human and environment, we have developed our institutional structure day by day with ISO 14001 Environmental Management System Certificate and TS 18001 Occupational Healthy and Safety Certificate since 2007.
Our products have been subjected to pressure and performance tests before sales by Quality Control Department and technical support services have been given at the installation, operation and maintenance stages after sales by our experienced engineers.
Our company who have continued R&D investments in order to present more quality and reliable products to his costumers, will continue its costumer-satisfaction focused services with increasing achievements in future thanks to his dynamic staff, powerful brand and permanent developing structure.
Company Profile
armas.com.tr
Table of Contents
600 SeriesHydraulic Control Valves
Armaş 600 SeriesGeneral Features
Operating PrincipalsMain Parts
Technical Specifications-Available ModelsDimension and Weights
Diaphragm Selection TableHydraulic Performance
M Manual Hydraulic Control ValveEL Solenoid Controlled Valve
PR Pressure Reducing Control ValvePREL Solenoid Controlled Pressure Reducing Valve
PS Pressure Sustaining Control ValveDIF Differential Pressure Sustaining Valve
PRPS Pressure Reducing and Sustaining Control ValveFL Float Level Control Valve
FLEL Electric Float Level Control ValveDIFL Differential Float Level Control Valve
FR Flow Rate Control ValveQR Quick Pressure Relief Valve
SA Surge Anticipating Control ValveHCV Hydraulic Check Valve
PC Pump (Booster) Control ValveDPC Deep Well (Submersible) Pump Control Valve
BF Back Flushing Control Valve
45678
10111214161922242628303234363842444648
armas.com.tr4
Features
General Description
•Easy use and maintenance due to simple design•Low cost•Operation in wide pressure range•Perfect modulation even in lower flow rates•Anti-surge closing and opening with flexible diaphragm•Full tightness thanks to reinforced diaphragm and inner spring•Long life with epoxy-polyester coating•Wide control application range by using different pilot valves•Operation in both horizontal and vertical positions in application areas
Armaş 600 series valves are the direct diaphragm closing automatic hydraulic control valves which work with line pressure. It ensures easy and smooth flow with minimum pressure losses thanks to excellent design of valve body and diaphragm. No wearable parts such as stem, bearing and seat exist in main valve body, valve life is much longer than other competitor valves. Only movable part of valve is vale diaphragm. Armaş 600 serial hydraulic control valves are designed so that it can be used in potable water force network, agricultural irrigation, fire fighting, filtration, industrial applications by even an unskilled personal.
600 SeriesHydraulic Control Valves
600 SeriesHydraulic Control Valves
armas.com.tr 5
Valve Closing ModeWhen pilot valves connected on main valve transport water pressure in valve upstream to valve actuator (control chamber), water creates a hydraulic power on valve diaphragm. This power formed, by combining with extra power applied by inner spring, ensures that valve will be closed as full tightness.
Valve Opening ModeWhen way of pilot valve located on main valve being in closedposition is brought into relief position, pressurized water within control chamber on main valve diaphragm is released. When line pressure (P1) reaches to the value which will overcome spring power, water carries valve to fully open position by applying a hydraulic power to valve diaphragm from bottom.
Modulation ModePilot valves which are connected to main valve actuator ensurethat main valve works in modulated mode. According to flowrate or pressure conditions, it ensures that main valve works in modulated mode by controlling pressure of fluid within main valve actuator (control chamber).
Working PrincipalsIt is automatic hydraulic control valve designed for make desired modulation processes in main valve network line as full hydraulically by means of line pressure without requiring different energy sources such as electric, pneumatic on mechanic energy.
armas.com.tr6
Main Parts and Technical Specifications
NO Part Name Material
1 Body Standard: GG25 (Cast Iron)Optional: GGG40 (Ductile Iron)
2 Diaphragm Standard: Nylon reinforced Natural RubberOptional: EPDM, Nitrile, Neoprene
3 Spring Thrust Ring Polyamide
4 Cover Standard: GG25 (Cast Iron)Optional: GGG40 (Ductile Iron)
5 Spring Standard: SST 302 Optional: SST 316
6 Washer Coated Steel
7 Bolt Coated Steel
8 Lifting eye-bolt Coated Steel
Main Parts
armas.com.tr 7
Available Models
Technical Specifications
Pressure Rating
Standard 0,7-16 bar (10-240 psi)
Low Pressure Range 0,5-10 bar (7,5-160) psi
High Pressure Range 0,7-25 bar (10-360 psi)
TemparatureMin. Operating Temperature - 10 °C (14 °F) DIN 2401/2
Max. Operating Temperature 80 °C (176 °F) DIN 2401/2
Connection
Flanged DIN 2501, ISO 7005-2, ANSI
Threaded BSPT, NPT
Grooved End Victaulic
CoatingStandard Epoxy
Optional Polyester
Hydraulic ConnectionsStandard
Reinforced Nylon (Air Brake)Hydraulic PipeSAEJ 844
Optional Copper DIN 1057
Actuator Type Diaphragm Closing Type with Single Control Chamberand Diaphragm Actuator
Models
67 67D 66 66D 64 63 63D
Connection Flanged Flanged Threaded Threaded Threaded Grooved End Grooved End
Material GG25 GGG40 GG25 GGG40 GG25 GG25 GGG40
Body Globe Globe Globe Globe Angle Globe Globe
Maximum OperatingPressure
16 bar240 psi
25 bar360 psi
16 bar240 psi
25 bar360 psi
16 bar240 psi
16 bar240 psi
25 bar360 psi
Available Sizes
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
2 50 2 50 1½ 40 1½ 40 2 50 2 50 2 50
2½ 65 2½ 65 2 50 2 50 2½ 65 2½ 65 2½ 65
323 80*50 323 80*50 2½ 65 2½ 65 3 80 3 80 3 80
3 80 3 80 323 80*50 323 80*50 4 100 4 100
4 100 4 100 3 80 80 80
5 125 5 125
6 150 6 150
8 200 8 200
10 250 10 250
12 300 12 300
14 350 14 350
16 400 16 400
armas.com.tr8
Weight and Dimension
DN D L H Weight
inch mm inch mm inch mm inch mm Lbs kg.
2 50 6,49 165 7,87 200 5,9 150 15,4 7
2½ 65 7,28 185 8,46 215 6,1 155 21 9,5
323 80*50 7,87 200 8,46 215 6,3 160 22,2 10
3 80 7,87 200 11,4 290 6,7 172 36,3 16,5
4 100 8,66 220 12 305 7 180 40,7 18,5
5 125 9,84 250 14,3 365 7,87 200 52,8 24
6 150 11,2 285 15,7 400 12 305 104,5 47,5
8 200 13,3 340 19,2 490 15 383 177,1 80,5
10 250 15,5 395 21 535 17,5 445 255,2 116
12 300 17,5 445 22,8 580 19,6 495 343,2 156
14 350 20,6 524 25,9 660 20,4 520 423,2 192
16 400 23,4 596 27,1 690 24,6 625 476,1 216
model 67
DN D L H Weight
inch mm inch mm inch mm inch mm Lbs kg.
2 50 6,49 165 7,87 200 5,9 150 18,7 8,5
2½ 65 7,28 185 8,46 215 6,1 155 22,2 11
323 80*50 7,87 200 8,46 215 6,3 160 27,5 12,5
3 80 7,87 200 11,4 290 6,7 172 46,2 21
4 100 8,66 220 12 305 7 180 51,7 23,5
5 125 9,84 250 14,3 365 7,87 200 61,6 28
6 150 11,2 285 15,7 400 12 305 118,8 54
8 200 13,3 340 19,2 490 15 383 237,6 108
10 250 15,5 395 21 535 17,5 445 290,4 132
12 300 17,5 445 22,8 580 19,6 495 385 175
14 350 20,6 524 25,9 660 20,4 520 462,9 210
16 400 23,4 596 27,1 690 24,6 625 507 230
model 67D
armas.com.tr 9
DN D L H Weight
inch mm inch mm inch mm inch mm Lbs kg.
1½ 40 2,5 66 6,2 160 3,5 90 6,6 3
2 50 3,3 85 7,1 180 4,1 105 8,8 4
2½ 65 3,7 95 8,1 205 4,1 105 9,9 4,5
323 80*50 4,3 110 8,7 220 4,7 120 12,1 5,5
3 80 4,3 110 12,6 320 4,9 125 24,2 11
model 66
DN D L H Weight
inch mm inch mm inch mm inch mm Lbs kg.
2 50 3 80 5,1 130 5,1 130 6,6 3
2½ 65 3,5 90 6,3 160 6,3 160 11 5
3 80 4,3 110 8,3 210 8,3 210 24,2 11
model 64
DN D L H Weight
inch mm inch mm inch mm inch mm Lbs kg.
1½ 40 2,5 66 6,2 160 3,5 90 8,8 4
2 50 3,3 85 7,1 180 4,1 105 11,4 5,2
2½ 65 3,7 95 8,1 205 4,1 105 14,3 6,5
323 80*50 4,3 110 8,7 220 4,7 120 17,6 8
3 80 4,3 110 12,6 320 4,9 125 28,6 13
model 66D
DN D L H Weight
inch mm inch mm inch mm inch mm Lbs kg.
2 50 2,4 60 7,1 180 3,7 95 6,6 3
2½ 65 2,9 75 8,3 210 3,9 100 8,8 4
3 80 3,5 90 12 305 4,7 120 24,2 11
4 100 4,5 115 12,2 310 4,9 125 28,6 13
model 63
DN D L H Weight
inch mm inch mm inch mm inch mm Lbs kg.
2 50 2,4 60 7,1 180 3,7 95 9,4 4,3
2½ 65 2,9 75 8,3 210 3,9 100 12,5 5,7
3 80 3,5 90 12 305 4,7 120 28,6 13
4 100 4,5 115 12,2 310 4,9 125 35,6 16,2
model 63D
armas.com.tr10
Size Diaphragm Pressure Range
inch mm Tipi No mSS psi
1½ 40 Standard # 02 4 - 100 6 - 160
2323
5080-50-80
Low Pressure # 03 4 - 100 6 - 160
Standard # 05 7 - 160 10 - 230
High Pressure # 07 10 - 250 15 - 360
2½ 65
Low Pressure # 03 4 - 100 6 - 160
Standard # 05 7 - 160 10 - 230
High Pressure # 07 10 - 250 15 - 360
3 80
Low Pressure # 13 4 - 100 6 - 160
Standard # 15 7 - 160 10 - 230
High Pressure # 17 10 - 250 15 - 360
4 100
Low Pressure # 13 4 - 100 6 - 160
Standard # 15 7 - 160 10 - 230
High Pressure # 17 10 - 250 15 - 360
5 125
Low Pressure # 13 4 - 100 6 - 160
Standard # 15 7 - 160 10 - 230
High Pressure # 17 10 - 250 15 - 360
6 150
Low Pressure # 23 4 - 100 6 - 160
Standard # 25 7 - 160 10 - 230
High Pressure # 27 10 - 250 15 - 360
8 200
Low Pressure # 33 4 - 100 6 - 160
Standard # 35 7 - 160 10 - 230
High Pressure # 37 10 - 250 15 - 360
10 250
Low Pressure # 43 4 - 100 6 - 160
Standard # 45 7 - 160 10 - 230
High Pressure # 47 10 - 250 15 - 360
12 300
Low Pressure # 33 4 - 100 6 - 160
Standard # 35 7 - 160 10 - 230
High Pressure # 37 10 - 250 15 - 360
14 350
Low Pressure # 43 4 - 100 6 - 160
Standard # 45 7 - 160 10 - 230
High Pressure # 47 10 - 250 15 - 360
16 400
Low Pressure # 33 4 - 100 6 - 160
Standard # 35 7 - 160 10 - 230
High Pressure # 37 10 - 250 15 - 360
Diaphragm Selecting Table
armas.com.tr 11
Valve Size
mm 40 50 65 80-50-80 80 100 125 150 200 250 300 350 400
inch 1½ 2 2½ 323 3 4 5 6 8 10 12 14 16
Kv m3/h @ 1 bar 35 50 50 50 130 200 200 450 800 1250 1800 2000 2600
Cv gpm @ 1 psi 45 60 60 60 150 231 231 520 925 1450 2080 2310 3005
Cavitation Chart
Hydraulic Performance
Upstream Pressure
(bar)
Downstream Pressure
(bar)
2
1 2 3 4 5 6 7 8
4
6
8
10
12
14
16
18
20
22
24
Head Loss Chart
Hea
d Lo
ss (m
SS)
Flow Rate (m3/h)
10
10 100 1000
DN40(1½")DN50(2") - DN65(2½") - DN80-50-80(3"2"3")DN80(3")DN100(4") - DN125(5")DN150(6")DN200(8")DN250(10")DN300(12")DN350(14")DN400(16")
1½"
2"-2
½"-3
"2"3
"
3" 4"-5
"
6" 8" 10"
12 14"
16"
1
Cavitation Zone
Noisy Operation Zone
Safety Zone
KvCvQ
G
: Valve Flow Coefficient (fluid passing in 1 bar pressure lose in m3/h and 1 bar ): Valve Flow Coefficient (fluid passing in 1 bar pressure lose in gpm and 1 psi ): Flow Rate (m3/h, gpm): Head Loss (bar, psi): Specific weight of water (1.0)
P
armas.com.tr12
Control ValveManual Hydraulic M
Description
Installation
Typical Application
Armaş “M” model valve is the hydraulic control valve operated by line pressure and designed to ensure opening/closing process by means of 3-way selector valve. Minimum opening pressure of valve is 0.7 bar. Thanks to its flexible diaphragm, it makes easy and fast control process in high pressure applications and is closed as full tightness without causing surge. It may be used in different applications by adding different pilot valves on its main body.
• Make sure that valve is on a level with the pipeline while mounting it.• Mount valve in direction of arrow indicated on it.• While connecting valve on pipeline, place gasket between valve flange and pipe flange to ensure sealing and tighten the bolts as crosswise.• Mount valve body in reservoir or tank upstream and mount float components as fixed in desired level interval.• It is recommended that insulation valves (butterfly or gate valves etc.), air relief valve and strainer valves will be used in line-mounting of valve
Manual Control Valve1
a
b c d
1
3- way selector valve
Ball Valve
In-line Finger Filter
Plug
a c
b d
armas.com.tr 13
Adjustment
Maintenance
Troubleshooting
Sample order form
• Select adjustment position by means of 3-way selector valve indicated with “a” on main valve.• Valve is open in “Open” position and closed in “Close” position
• Check finger filter in valve upstream according to water quality.• Drain water within actuator of valve not used in winter.
Failure Causes Correcting/Repair
Valve not opening• Line pressure may be low.• 3-way selector valve may be closed.• 3-way selector valve may be clogged
• Check valve upstream pressure and ensure necessary upstream pressure. • Check 3-way selector valve and bring it into “Open” position. • Check 3-way selector valve and clean it.
Valve not closing
• Diaphragm may be punctured.• Foreign substances may exist in diaphragm seat.• 3-way selector valve may be open.• 3-way selector valve may be clogged.
• Check diaphragm and replace with the new one if it is punctured. • Check diaphragm seat and remove foreign substances if any. • Check 3-way selector valve and bring it into “Close” position. • Check 3-way selector valve and clean it.
Model Connection Size Control Feature Additional Features Options
67-67D
66-66D-64
63-63D
F: Flanged (ISO-ANSI)
TH: Threaed (BSPT-NPT)
VIC: Grooved End
2"-16"
1½"-3"
2"-4"
Manual Control
EL: Electric Control
NV: On/Off Speed Adjustment
PG: Pressure Gauge
Position
Indicator
67 F 6" M NV PIR
Please submit following information to our sales department while ordering.
Maximum flow rate m³/hMaximum network/line pressure barMain line size mmValve connection type
Order Information
armas.com.tr14
Description
Installation
Adjustment
Typical Application
Armaş “EL” model valve is the hydraulic control valve operated by line pressure and designed to ensure opening/closing process by means of built-in 3/2-way solenoid pilot valves controlled remotely with electric signal. Electric signal for solenoid pilot valves is ensured by means of a control device, time relay, main switch and PLC control units etc. Opening/Closing process may be realized easily thanks to manual control on solenoid pilot valve. Depending on desire, 24V AC 50Hz/60Hz or 12V DC, 9V DCLATCH and 12V DC latch normally open (N.O.) or normally closed (N.C.) solenoid coils may be used on main valve.
• Make sure that valve is on a level with the pipeline while mounting it.• Mount valve in direction of arrow indicated on it.• While connecting valve on pipeline, place gasket between valve flange and pipe flange to ensure sealing and tighten the bolts as crosswise.• Mount valve body in reservoir or tank upstream and mount float components as fixed in desired level interval.• It is recommended that insulation valves (butterfly or gate valves etc.), air relief valve and strainer valves will be used in line-mounting of valve
• Connect solenoid pilot valve cables indicated with "e" in accordance with control device.• Operate pump. Open main valve on network and deliver water to the system.• Open "b1" ball valve in valve upstream. Then bring 3-way selector valve indicated with "a" on valve into "Auto" position.
Controller
Solenoid Control Valve
1
2
2
1
3- way selector valve
Ball Valve
In-line Finger Filter
Plug
Solenoid Pilot Valve
a d
b
c
e
a
b c d
e
ELControlled ValveSolenoid
armas.com.tr 15
Please submit following information to our sales department while ordering.
Maximum flow rate m³/hMaximum network/line pressure barMain line size mmValve connection type Electric voltage value to be used volt
Maintenance
Solenoid Pilot Valve Specifications
• Check finger filter in valve upstream according to water quality.• Drain water within actuator of valve not used in winter.
Body Function Voltage Power Options
Brass-16 bar 3-way N.O.3-way N.C. 6,12,24,110,240
AC 8W - 5,5W 50 HzAC 8W - 5,5W 60 Hz
DC 5,5 W
0,8 mm1,6 mm2,0 mm
Plastic-12 bar 3-way N.O.3-way N.C.
6,12,249,12
AC,DCLatch
Failure Causes Correcting/Repair
Valve not opening
• 3-way selector valve may be closed. • Ports of Solenoid or 3-way valves may be clogged. • Line pressure may be low. • Voltage value of Solenoid Pilot valve may be wrong.• Solenoid coil may be burnt.
• Check 3-way selector valve and bring it into “Auto” position. • Check ports and clean them if clogged. • Check valve upstream pressure and ensure necessary upstream pressure. • Measure voltage value and select cable with suitable diameterfor coil.• Replace coil.
Valve not closing
•Diaphragm may be punctured. • Foreign substances may exist in diaphragm seat. • Manual control screw of Solenoid valve may be in wrong position. • Solenoid valve may be clogged. • Finger filter may be clogged.
• Check diaphragm and replace with the new one if it is punctured. • Check diaphragm seat and remove foreign substances if any. • Check control screw of Solenoid valve and bring it into suitable position if it is wrong. • Replace with new one. • Clean if it is clogged.
Sample order form
Model Connection Size Control Feature Additional Features Options
67-67D
66-66D-64
63-63D
F: Flanged (ISO-ANSI)
TH: Threaed (BSPT-NPT)
VIC: Grooved End
2"-16"
1½"-3"
2"-4"
Electric Control
SV-3: 3-Way Selector Valve
NV: On/Off Speed Adjustment
PG: Pressure Gauge
Position
Indicator
67 F 6" EL NV PIR
Order Information
Troubleshooting
armas.com.tr16
Description
Installation
Armaş “PR” model pressure reducer control valve is the hydraulic control valve which reduces high upstream pressure value into desired lower pressure value by means of built-in pressure reducing pilot valves. Pressure reducer control valve controls downstream pressure value continuously and maintains it constant without being affected from flow rate and upstream pressure values. When no flow exists in the system, it is closer by itself automatically. When valve upstream pressure value decreases below adjusted downstream pressure value, it is opened fully by itself. Valve may be user in vertical and horizontal positions in the system.
• Valve nominal diameter must equal to or one size smaller than line diameter. • Mount valve in direction of arrow indicated on it. • It is recommended that insulation valves (butterfly or gate valves etc.), air relief valve and strainer valves will be used in line-mounting of valve • During pressure decrease, cavitation risk is dangerous for valve body. Adjust downstream pressure value by referring cavitation data or consult our technical service.
Pressure Reducing Pilot Valve
Ball Valves
In-line Finger Filter
Pressure Gauge
Adjustment Bolt
a
a
d
d
b
b1 b2
c
c
e
e
Typical Application
Isolation Valve (Gate, Butterfly Valve etc.)
Strainer
Pressure Reducing Valve
Air Valve
Quick Pressure Relief Valve
1
1
1
1
1
2
2
3
3
3
5
4
4
5
Control ValvePressure Reducing PR
armas.com.tr 17
Adjustment• Operate pump. Open main valve on network and deliver water to the system. • Open ball valve indicated with "b1" and close ball valve indicated with "b2". • Wait for a while until water reach valve control chamber. When water reach control chamber, pressure gauge will show a certain pressure value. • Adjust desired downstream pressure value by means of adjustment bolt with "e" on pilot valve indicated with "a" by referring pressure gauge indicated with "d". • When you turn adjustment bolt clockwise, downstream pressure value will increase and when you turn adjustment bolt counter-clockwise it will decrease. • After adjusting desired downstream pressure value, tighten contra nut below adjustment bolt. Open ball valve indicated with "b2" and deliver water into system. Pressure gauge will show zero value after opening "b2" valve. • Check downstream pressure value continuously. If valve regulating process is not realized, consult our company.
Failure Causes Correcting/Repair
Valve not opening
• Ball valves in valve upstream and downstream may be close. • Valve upstream pressure may be too low. • Adjustment bolt of pilot valve may be too loosened.
• Check ball valves and open them if they are closed.
• Check your system. • Bring adjustment bolt into desired value and tighten contra nut.
Valve not closing
• Diaphragm may be punctured. • Foreign substances may exist in diaphragm seat. • Connections of pilot valve may be clogged because of foreign substances. • Finger filter may be clogged.
• Check diaphragm and replace with the new one if it is punctured. • Check diaphragm seat and remove foreign substances if any. • Check connections and clean them.
• Clean if it is clogged.
Valve does not regulate
•Movable parts of pilot valve may be clogged because of calcification. •Needle valve or orifice in pilot valve upstream may be clogged. •Pressure gauge may be failed.
•Replace with new one.
•Clean it.
•Replace with new one.
Troubleshooting
armas.com.tr18
Please submit following information to our sales department while ordering.
Maximum flow rate m³/hMaximum network/line pressure barMain line size mmValve connection type Maximum upstream pressure barMinimum upstream pressure barDesired downstream pressure bar
Pilot Valve Pressure Adjustment RangeStandard Pressure Range 5 - 160 m 7,5 - 240 psi
Medium Pressure Range 10 - 100 m 15 - 150 psi
High Pressure Range 5 - 240 m 7,5 - 360 psi
Sample order form
Maintenance• Check finger filter indicated with "c" according to water quality and clean it. Do not make cleaning more than one within a few months unless water is too dirty. • Drain water within actuator and pilot valves of valves not used in winter.
Model Connection Size Control Feature Additional Features Options
67-67D
66-66D-64
63-63D
F: Flanged (ISO-ANSI)
TH: Threaed (BSPT-NPT)
VIC: Grooved End
2"-16"
1½"-3"
2"-4"
Pressure Reducing
EL: Electric Control
NV: On/Off Speed Adjustment
PG: Pressure Gauge
SV-3: 3-Way Selector Valve
Position
Indicator
67 F 6" PR EL PIR
Order Information
armas.com.tr 19
Description
Installation
Typical Application
Armaş “PREL” model pressure reducing valve is the hydraulic control valve which reduces high upstream pressure value into desired lower pressure value. Control of main valve is achieved by means of built-in 3/2 -way solenoid pilot valves. Electric signal for solenoid pilot valves is ensured by means of a control device, time relay, main switch and PLC control units etc. Automated control may be easily ensured by this way in application systems.
• Connect cables of solenoid pilot valve in accordance with control device. • Make sure that is on a level with the pipeline while mounting it. • Mount valve in direction of arrow indicated on it. • It is recommended that insulation valves (butterfly or gate valves etc.), air relief valve, quick pressure relief valve (QR), and strainer valves will be used in line-mounting of valve (See sample montage illustration). • During pressure decrease, cavitation risk is dangerous for valve body. Adjust downstream pressure value by referring cavitation data or consult our technical service.
Controller
Air Valve
Watermeter
Filter
Solenoid Controlled Pressure Reducing Valve
1
2
3
5
4
Pressure Reducing Pilot Valve
Ball Valves
In-line Finger Filter
Solenoid Pilot Valve
Pressure Gauge
Adjustment Bolt
a d
b
c
e
f
f
1
2 3 4
5
e
b1 c b2
ad
PREL Solenoid ControlledPressure Reducing Valve
armas.com.tr20
Adjustment• Operate pump. Open main valve on network and deliver water to the system. • Open ball valve indicated with "b1". • Make system active by giving energy to coil of solenoid pilot valve from your control device. • Adjust desired downstream pressure value by means of adjustment bolt indicated with "f" on pilot valve indicated with "a" by referring pressure gauge indicated with "d". • When you turn adjustment bolt clockwise, downstream pressure value will increase and when you turn adjustment bolt counter-clockwise it will decrease. • After adjusting desired downstream pressure value, tighten contra nut below adjustment bolt. Open ball valve indicated with "b2" and deliver water into system. Pressure gauge will show zero value after opening "b2" valve.
Failure Causes Correcting/Repair
Valve not opening
• Ball valves in valve upstream and downstream may be close. • Valve upstream pressure may be too low. • Adjustment bolt of pilot valve may be too loosened. • Voltage value of solenoid pilot valve may be wrong. • Solenoid coil may be burnt.
• Check ball valves and open them if they are closed.
• Check your system. • Bring adjustment bolt into desired value and tighten contra nut.
• Measure voltage value and select cable with suitable diameter for coil.
• Replace coil.
Valve not closing
• Diaphragm may be punctured. • Foreign substances may exist in diaphragm seat. • Connections of pilot valve may be clogged because of foreign substances. • Finger filter may be clogged. • Manual control screw of solenoid valve may be in wrong position.
• Check diaphragm and replace with the new one if it is punctured. • Check diaphragm seat and remove foreign substances if any. • Check connections and clean them. • Clean if it is clogged. • Check manual control screw.
Valve does not regulate
• Movable parts of pilot valve may be clogged because of calcification. • Needle valve or orifice in pilot valve upstream may be clogged. • Pressure gauge may be failed.
• Replace with new one. Bring it into correct position if not. • Clean it.
• Replace with new one.
Troubleshooting
armas.com.tr 21
Please submit following information to our sales department while ordering.
Maximum flow rate m³/hMaximum network/line pressure barMain line size mmValve connection type Maximum upstream pressure barMinimum upstream pressure barDesired downstream pressure barElectric voltage value to be used volt
Sample order form
Solenoid Pilot Valve Specifications
Body Function Voltage Power Options
Brass-16 bar 3-way N.O.3-way N.C. 6,12,24,110,240
AC 8W - 5,5W 50 HzAC 8W - 5,5W 60 Hz
DC 5,5 W
0,8 mm1,6 mm2,0 mm
Plastic-12 bar 3-way N.O.3-way N.C.
6,12,249,12
AC,DCLatch
Pilot Valve Pressure Adjustment RangeStandard Pressure Range 5 - 160 m 7,5 - 240 psi
Medium Pressure Range 10 - 100 m 15 - 150 psi
High Pressure Range 5 - 240 m 7,5 - 360 psi
Model Connection Size Control Feature Additional Features Options
67-67D
66-66D-64
63-63D
F: Flanged (ISO-ANSI)
TH: Threaed (BSPT-NPT)
VIC: Grooved End
2"-16"
1½"-3"
2"-4"
Solenoid ControlledPressure Reducing
NV: On/Off Speed Adjustment
PG: Pressure Gauge
SV-3: 3-Way Selector Valve
Position
Indicator
67 F 6" PREL NV PIR
Order Information
armas.com.tr22
Control ValvePressure Sustaining PS
Description
Adjustment
Armaş “PS” model pressure sustaining hydraulic control valve maintains valve upstream pressure value constant. Valve is opened when line pressure reaches adjusted valve pressure level. It ensures that pump motor within pumping systems will start without load. It also prevents positive pressure waves caused by pump during start-up. Valve controls upstream pressure value continuously and keeps it in a constant value without being affected from changes in flow rates. When no flow exists, it is closed by itself as fully tightness.
• Operate pump. Open main valve on network and deliver water to the system. • Open ball valve indicated with "b1" and "b2". • Wait for a while until water reach valve control chamber. When water reach control chamber, pressure gauge will show a certain pressure value. • Adjust desired downstream pressure value by means of adjustment bolt indicated with "e" on pilot valve indicated with "a" by referring pressure gauge indicated. • After adjusting desired downstream pressure value, tighten contra nut below adjustment bolt. Pressure gauge will show upstream pressure value. Check finger filter indicated with “c” according to water quality and clean it. Do not make cleaning more than one within a few months unless water is too dirty.• Drain water within actuator and pilot valves of valves not used in winter.
Typical ApplicationPressure Sustaining Valve
Air Valve
Pump
Isolation Valve (Gate, Butterfly Valve etc.)
1
2
3
4
Pressure Sustaining Pilot Valve
Ball Valves
In-line Finger Filter
Pressure Gauge
Adjustment Bolt
a d
b
c
e
b2b1
a
c
d
e
1
2
3
4
armas.com.tr 23
Failure Causes Correcting/Repair
Valve not opening
• Ball valve downstream may be closed. • Valve upstream pressure may be too low. • Adjustment pressure of pilot valve may be too high. • Needle valve on pilot valve may be closed.
• Check ball valves and open them if they are closed. • Check your system. • Bring pressure value into adjusting value by means of adjustment bolt.
• Open needle valve one or two tours according to system adjustment.
Valve not closing
• Diaphragm may be punctured. • Foreign substances may exist in diaphragm seat. • Connections of pilot valve may be clogged because of foreign substances. • Finger filter may be clogged.
• Check diaphragm and replace with the new one if it is punctured. • Check diaphragm seat and remove foreign substances if any. • Check connections and clean them.
• Clean if it is clogged.
Valve does not regulate
• Movable parts of pilot valve may be clogged because of calcification. • Needle valve or orifice in pilot valve upstream may be clogged. • Pressure gauge may be failed.
• Replace with new one. Bring it into correct position if not. • Clean it. • Replace with new one.
Sample order form
Model Connection Size Control Feature Additional Features Options
67-67D
66-66D-64
63-63D
F: Flanged (ISO-ANSI)
TH: Threaed (BSPT-NPT)
VIC: Grooved End
2"-16"
1½"-3"
2"-4"
Pressure Sustaining
SV-3: 3-Way Selector Valve
NV: On/Off Speed Adjustment
EL: Electric Control
Position
Indicator
67 F 6" PS EL PIR
Please submit following information to our sales department while ordering.
Maximum flow rate m³/hMaximum network/line pressure barMain line size mmValve connection type Desired upstream pressure bar
Order Information
Troubleshooting
Pilot Valve Pressure Adjustment RangeStandard Pressure Range 5 - 160 m 7,5 - 240 psi
Medium Pressure Range 10 - 100 m 15 - 150 psi
High Pressure Range 5 - 240 m 7,5 - 360 psi
armas.com.tr24
Description
Installation
Armaş “DIF” model Differential Pressure Sustaining Valve is the hydraulic control valve which maintains a preset pressure differential between its upstream and downstream sides. Required upstream pressure can be adjusted by the pilot easily. The valve can control heating and cooling systems, booster pump discharge, bypass lines, filters and other similar systems.
• When connect the valve to the pipeline, please make sure that it should be same position with the pipeline.• Mount valve in direction of arrow indicated on it.• When connect the valve to the pipeline, please add a gasket for providing leak proofing between valve’s flange and pipe’s flange and tighten the bolts cross.• It is recommended that insulation valves (butterfly or gate valves etc.), air relief valve, quick pressure relief valve (QR) and strainer valves will be used in line-mounting of valve.
Typical Application
3- way selector valve
Ball Valves
In-line Finger Filter
Differential Pressure Sustaining Pilot
Pressure Gauge
a d
b
c
e
3
54
11 1 1
2
1
Isolation Valve (Gate, Butterfly Valve etc.)
Strainer
Differential Pressure Sustaining Valve
Pump
Check Valve
1 4
2
3
5
e
c
a
b1
b2d
Control ValveDifferential Pressure Sustaining DIF
armas.com.tr 25
Please submit following information to our sales department while ordering.
Maximum flow rate m3/hMaximum network/line pressure barMain line size mmValve connection type Maximum upstream pressure barMinimum upstream pressure barDesired pressure difference value bar
Adjustment• Open ball valves (b1) and (b2) which are located on the valve. • Operate pump, open main valve on network and deliver water to the system. • Turn the adjustment bolt which is located on the pilot valve (d) to anticlockwise. Upstream and downstream pressure will be equal. • Make sure that the air inside of the system has discharged. • Adjust upstream and downstream pressure difference by use adjustment bolt which is located on the pilot valve. • When adjustment bolt is tighten to clockwise, upstream and downstream pressure difference is increased. If the bolt is tighten to anticlockwise, upstream and downstream pressure difference is decreased.
Failure Causes Correcting/Repair
Valve not opening
• Ball valves in valve upstream and downstream may be closed. • Valve upstream pressure may be too low. • Adjustment pressure of the pilot valve can be higher than line pressure. • Needle valve which is located on the pilot valve can be closed.
• Check ball valves and open them if they are closed. • Check your system. • Bring pressure value into adjusting value by means of adjustment bolt. • Open needle valve one or two tours according to system adjustment.
Valve not closing
• Diaphragm may be punctured. • Foreign substances may exist in diaphragm seat. • Connections of pilot valve may be clogged because of foreign substances. • Finger filter may be clogged.
• Check diaphragm and replace with the new one if it is punctured. • Check diaphragm seat and remove foreign substances if any. • Check connections and clean them.
• Clean if it is clogged.
Valve does not regulate
• Movable parts of pilot valve may be clogged because of calcification. • Needle valve adjusting point may be wrong. • Pressure gauge may be failed.
• Replace with new one. • Close needle valve fully and open it one to two tours. • Replace with new one.
Sample order form
Model Connection Size Control Feature Additional Features Options
67-67D
66-66D-64
63-63D
F: Flanged (ISO-ANSI)
TH: Threaed (BSPT-NPT)
VIC: Grooved End
2"-16"
1½"-3"
2"-4"
DifferentialPressure Sustaining
SV-3: 3-Way Selector Valve
NV: On/Off Speed Adjustment
EL: Electric Control
Position
Indicator
67 F 6" DIF EL PIR
Order Information
Troubleshooting
armas.com.tr26
Control Valve
DescriptionArmaş “PRPS” model pressure reducing/sustaining hydraulic control valve reduces valve downstream pressure to desired value by sustaining upstream pressure. Two pilot valves exist on valve. Pilot valve on upstream side is the pressure sustaining pilot valve and sustains upstream pressure. Other pilot valve is pressure reducing pilot valve and keeps downstream pressure constant by reducing it to desired value. Reducing/sustaining control valve pumps fluid downwards; it ensures that system works within normal values by regulating over flow and high pressure in pumping systems. It controls upstream and downstream pressure continuously and keeps them within constant values.
Adjustment• Operate pump, open main valve on network and deliver water to the system.• Open ball valves indicated with “b1” and close ball valve indicated with “b2”.• Adjust desired upstream pressure value by means of adjustment bolt indicated with “e” on pressure sustaining pilot valve indicated with “a” by referring pressure gauge. Tighten contra nut after determining set point.• Adjust pressure reducing pilot valve indicated with “d” by means of adjustment bolt indicated with “f” on it by referring pressure gauge. Pressure gauge indicated with “e” on pressure reducing pilot valve will show valve downstream pressure value.• When you turn adjustment bolt of both pilot valves clockwise, downstream pressure value will increase and when you turn adjustment bolt counter-clockwise it will decrease.• After adjusting desired pressure set point on both pilot valves, open spherical valve indicated with “b2” and deliver water to system. During normal operation of valve, upstream pressure gauge will show valve upstream pressure value and downstream pressure gauge will show zero value. Close spherical valve indicated with “b2” to see downstream pressure value.
Typical Application
Pressure Reducing and Sustaining Valve
Strainer
Air Valve
1
2
3
Pressure Sustaining Pilot Valve
Ball Valves
In-line Finger Filter
Pressure Reducing Pilot Valve
Pressure Gauge
Adjustment Bolt
a d
b
c
e
e
f
fa
b1 b2c
d
3
2
1
Pressure Reducing and Sustaining PRPS
armas.com.tr 27
Please submit following information to our sales department while ordering.
Maximum flow rate m³/hMaximum network/line pressure barMain line size mmValve connection type Maximum upstream pressure barMinimum upstream pressure barDesired downstream pressure barDesired upstream pressure bar
Maintenance• Check finger filter indicated with “c” according to water quality and clean it. Do not make cleaning more than one within a few months unless water is too dirty.• Drain water within actuator and pilot valves of valves not used in winter.• Check downstream pressure value continuously.• Consult our company if valve does not perform regulation and control functions
Failure Causes Correcting/Repair
Valve not opening
• Ball valves in valve downstream may be closed. • Valve upstream pressure may be too low.• Adjustment pressure of the pilot valve may be too high. • Needle valve on pilot valve may be closed. • Adjustment bolt of pilot valve may be too loose.
• Check ball valves and open them if they are closed. • Check your system. • Bring pressure value into adjusting value by means of set screw. • Open needle valve one or two tours according to system adjustment. • Bring adjustment bolt into desired value tighten contra nut.
Valve not closing
• Diaphragm may be punctured. • Foreign substances may exist in diaphragm seat.• Connections of pilot valve may be clogged because of foreign substances. • Finger filter may be clogged.
• Check diaphragm and replace with the new one if it is punctured. • Check diaphragm seat and remove foreign substances if any. • Check connections and clean them.
• Clean if it is clogged.
Valve does not regulateValve does not regulate
• Movable parts of pilot valve may be clogged because of calcification. • Needle valve adjusting point on Pressure Sustaining Pilot Valve may be wrong. • Pressure gauge may be failed.
•Replace with new one. •Close needle valve fully and open it one to two tours. •Replace with new one.
Sample order form
Model Connection Size Control Feature Additional Features Options
67-67D
66-66D-64
63-63D
F: Flanged (ISO-ANSI)
TH: Threaed (BSPT-NPT)
VIC: Grooved End
2"-16"
1½"-3"
2"-4"
Pressure Reducingand Sustaining
SV-3: 3-Way Selector Valve
NV: On/Off Speed Adjustment
EL: Electric Control
Position
Indicator
67 F 6" PRPS EL PIR
Order Information
Troubleshooting
Pilot Valve Pressure Adjustment RangeStandard Pressure Range 5 - 160 m 7,5 - 240 psi
Medium Pressure Range 10 - 100 m 15 - 150 psi
High Pressure Range 5 - 240 m 7,5 - 360 psi
armas.com.tr28
Description
Installation
Armaş “FL” model float level control valve is the hydraulic control valve designed to control water level in reservoirs and tanks continuously. Main valve is controlled by 2-way modulating type float pilot valve manually. Main valve mounted on reservoir and tank upstream is closed as fully sealed without causing surge when water level reaches to maximum level. Valve opening/closing speed may be adjusted in set value. It may be used in the system by mounting horizontal or vertical positions.
• Make sure that valve is on a level with the pipeline while mounting it.• Mount valve in direction of arrow indicated on it.• While mounting valve on pipeline, place gasket between valve flange and pipe flange to ensure sealing and tighten the bolts as crosswise.• Mount main valve body on tank or reservoir upstream and mount float components in tank or reservoir as fixed in desired level interval.• It is recommended that insulation valves (butterfly or gate valves etc.), air relief valve and strainer valves will be used in line-mounting of valve (see sample montage illustration).
Typical Application
Isolation Valve (Gate, Butterfly Valve etc.)
Modulating Type Float Level Control Valve
Air Valve
Float
Water Tank
1
1 2
2
3
3
4
5
5
Needle Valve
Ball Valves
In-line Finger Filter
Float
Plug
a d
b
c
e
a
b1 c e
b2d
12
3
5
4
4
Float Level FLControl Valve
armas.com.tr 29
Please submit following information to our sales department while ordering.
Maximum flow rate m³/hMaximum network/line pressure barMain line size mmValve connection type
Adjustment
Maintenance
• Mount float pilot valve indicated with “d” as fixed according to water level in tank or reservoir.• Connect one end of hydraulic pressure signal tube supplied with valve to ball valve indicated with “b2” and other end to float pilot valve.• Open ball valves indicated with”b1” and “b2”.• Needle valve indicated with “a” is used for adjusting opening/closing speed adjustment of main valve.
• Check finger filter indicated with “c” according to water quality and clean it. Do not make cleaning more than one within a few months unless water is too dirty.• Drain water within actuator and pilot valves of valves not used in winter.
Failure Causes Correcting/Repair
Valve not opening
• “b2 ball valve maybe closed. • Line pressure may be low. • Level of float pilot valve is not fixed. • Float Pilot valve may be clogged.
• Check “b2” ball valve and open if it is closed. • Check valve upstream pressure and ensure necessary upstream pressure. • Fix lever of float pilot valve to desired level. • Clean it.
Valve not closing
• Diaphragm may be punctured. • Foreign substances may exist in diaphragm seat. • Needle valve may be closed. • Float Pilot Valve may be failed.
• Check diaphragm and replace with the new one if it is punctured. • Check diaphragm seat and remove foreign substances if any. • Check needle valve and open it by one or two tours if it is closed. • Replace with the new one.
Sample order form
Model Connection Size Control Feature Additional Features Options
67-67D
66-66D-64
63-63D
F: Flanged (ISO-ANSI)
TH: Threaed (BSPT-NPT)
VIC: Grooved End
2"-16"
1½"-3"
2"-4"
Modulating Control
EL: Electric Control
NV: On/Off Speed Adjustment
PG: Pressure Gauge
SV-3: 3-Way Selector Valve
Position
Indicator
67 F 6" FL EL PIR
Order Information
Troubleshooting
armas.com.tr30
Description
Installation
Armaş “FLEL” model electrical float level control valve is the hydraulic control valve designed to control water level continuously by means of electrical float placed in reservoirs and tanks. Electrical float sends signal to solenoid coil on main valve when water level decreases below set level. Main valve is opened and ensures that tank or reservoir will be filled permanently. When water reaches maximum level, electrical float sends signal to solenoid coil again and main valve is closed as full sealed. Valve may be used in the system by mounting horizontal or vertical positions.
• Install cables of electrical float and solenoid pilot valve in accordance with control device to be used.• Mount valve in direction of arrow indicated on it.• While mounting valve on pipeline, place gasket between valve flange and pipe flange to ensure sealing and tighten the bolts as crosswise.• Mount main valve body on tank or reservoir upstream and mount float components in tank or reservoir as fixed in desired level interval.• It is recommended that insulation valves (butterfly or gate valves etc.), air relief valve and strainer valves will be used in line-mounting of valve
Typical Application
Controller
Electric Float Level Control Valve
Air Valve
Isolation Valve (Gate, Butterfly Valve etc.)
Water Tank
1
2
3
4
5
5
4
4
3- way selector valve
Ball Valve
In-line Finger Filter
Plug
Solenoid Pilot Valve
Electric Float Switch
a d
d
b
c
e
f
a
b c
e
f
1
2
3
Control ValveElectric Float Level FLEL
armas.com.tr 31
Please submit following information to our sales department while ordering.
Maximum flow rate m³/hMaximum network/line pressure barMain line size mmValve connection type Electric voltage value to be used volt
Adjustment
Maintenance
• Mount electrical float switch indicated with “f” as fixed according to water level in tank or reservoir and connect cables to control panel.• Connect cables of solenoid pilot valve indicated with “e” to control panel conveniently.• Bring 3-way selector valve on main valve indicated with”a” into “auto“position.• Open ball valve indicated with “b1”.
• Check finger filter indicated with “c” according to water quality and clean it. Do not make cleaning more than one within a few months unless water is too dirty.• Drain water within actuator and pilot valves of valves not used in winter.
Failure Causes Correcting/Repair
Valve not opening
• 3-Way selector valve may be closed. • Ports of solenoid or 3-way valve may be clogged. • Voltage value of solenoid pilot valve may be wrong. • Solenoid coil may be burnt. • Electrical float switch may be failed. • Line pressure may be low.
• Check 3-Way selector valve and bring it into “Auto” position. • Check ports and clean them if clogged.
• Measure voltage value and select cable with diameter suitable for coil • Replace coil. • Replace with the new one. • Check valve upstream pressure and ensure necessary upstream pressure.
Valve not closing
• Diaphragm may be punctured. • Foreign substances may exist in diaphragm seat.• Electrical float may be failed. • Finger filter may be clogged. • Control panel may be failed.
• Check diaphragm and replace with the new one if it is punctured. • Check diaphragm seat and remove foreign substances if any. • Check control screw, Bring it into correct position if it is wrong. • Clean if it is clogged. • Replace with the new one.
Sample order form
Model Connection Size Control Feature Additional Features Options
67-67D
66-66D-64
63-63D
F: Flanged (ISO-ANSI)
TH: Threaed (BSPT-NPT)
VIC: Grooved End
2"-16"
1½"-3"
2"-4"
ElectricalFloat Switch
NV: On/Off Speed Adjustment
PG: Pressure Gauge
SV-3: 3-Way Selector Valve
Position
Indicator
67 FL 6" FLEL NV PIR
Order Information
Troubleshooting
armas.com.tr32
Description
Installation
Armaş “DIFL” model float control valve is the hydraulic control valve designed to control water level in reservoirs and tanks in desired ranges. Main valve is closed as wholly sealed without surge when water reach desired level thanks to 4/3 way differential control pilot. Max. and min. water level in reservoir may be adjusted to desired value in a wide range. Thanks to this feature, pump does not put into/out of service frequently during level control of reservoir fed by pump. Valve controls water level and keeps it in desired range without being affected from flow rate and pressure changes. It may be used easily in reservoirs and tanks fed from both top and bottom.
• Make sure that valve is on a level with the pipeline while mounting it.• Mount valve in direction of arrow indicated on it.• While connecting valve on pipeline, place gasket between valve flange and pipe flange to ensure sealing and tighten the bolts as crosswise.• Mount valve body in reservoir upstream and float components as fixed in desired level interval.• It is recommended that insulation valves (butterfly or gate valves etc.), air relief valve and strainer valves will be used in line-mounting of valve.
Typical Application
Isolation Valve (Gate, Butterfly Valve etc.)
Differential Float Level Control Valve
Air Valve
Differential Float Assemble
1
2
3
4
3- way selector valve
Ball Valves
In-line Finger Filter
Plug
Differential Level Control Pilot Valve
a d
b
c
e
a
b c d
e
4 3
1
2
Control ValveDifferential Float Level DIFL
armas.com.tr 33
Please submit following information to our sales department while ordering.
Maximum flow rate m3/hMaximum network/line pressure barMain line size mmValve connection type Desired level control range m
Adjustment• Mount differential float pilot valve indicated with “e” as fixed according to water level in reservoir or tank.• Mount hydraulic pressure signal pipe on 3-way selector valve as described below;
Auto T Close P Relief V
• Open spherical valve indicated with”b1”.
Pilot Valve Differential Level Range
Pilot Valve Pressure Range
Standard Pressure Range 5 - 120 cm 2" - 48"
Medium Pressure Range 5 - 180 cm 2" - 70"
High Pressure Range 10 - 240 cm 4" - 95"
Minimum Working Pressure 0,5 bar -7 psi
Standard 16 bar - 230 psi
Maximum Working Pressure 25 bar - 360 psi
Failure Causes Correcting/Repair
Valve not opening
• 3-Way selector valve may be closed. • Montage of differential float pilot valve may be loose. • 3-way selector valve connection of differential pilot valve may be wrong. • Line pressure may be low.
• Check 3-Way selector valve and bring it into “Auto” position. • Mount differential float pilot valve as fixed.
• Check hydraulic connections and correct them.
• Check valve upstream pressure and ensure necessary upstream pressure.
Valve not closing
• Diaphragm may be punctured. • Foreign substances may exist in diaphragm seat. • Movable parts of differential float pilot valve may be clogged due to calcification. • Finger filter may be clogged.
• Check diaphragm and replace with the new one if it is punctured. • Check diaphragm seat and remove foreign substances if any. • Replace differential float pilot valve.
• Clean if it is clogged.
Sample order form
Model Connection Size Control Feature Additional Features Options
67-67D
66-66D-64
63-63D
F: Flanged (ISO-ANSI)
TH: Threaed (BSPT-NPT)
VIC: Grooved End
2"-16"
1½"-3"
2"-4"
DifferentialLevel Control
NV: On/Off Speed Adjustment
PG: Pressure Gauge
PS: Pressure Sustaining
EL: Electric Control
Position
Indicator
67 F 6" DIFL NV PIR
Order Information
Troubleshooting
armas.com.tr34
Description
Features
Installation
Armaş “FR” modell flow rate control valve is designed to limit desired flow rate. The orifice on main valve upstream creates pressure difference and 3/way differential pressure set pilot mounted in control chamber of valve senses this pressure difference and ensures that main valve opens in desired flow rate. Valve thereby limits desired flow rate automatically and keeps it fixed. It eliminates over flow by preventing excessive flow during reverse washing in filtration systems.
• Valve adjusts by itself automatically even in changing flow rates.• Valve is closed by itself as fully sealed in case no flow exists in the system.• Valve is opened fully when nominal flow rate decreases below limited flow rate.• Valve may be used in the system by mounting it vertical or horizontal positions
• Make sure that valve is on a level with the pipeline while mounting it.• Mount valve in direction of arrow indicated on it.• When orifice is connected to pipeline, mount in such a way that tightness between upstream flange and pipe flange will be ensured.• Mount hydraulic control lever of pilot valve before valve and orifice conveniently.• It is recommended that insulation valves (butterfly or gate valves etc.), air relief valve and strainer valves will be used in line-mounting of valve (see sample montage illustration).
Typical Application
Flow Rate Control Valve
Hydraulic Signal Line
Isolation Valve (Gate, Butterfly Valve etc.)
1
2
3
3- way selector valve
Ball Valve
In-line Finger Filter
Plug
Flow Rate Control Pilot Valve
Orifice Plate
a d
b
c
e
f
f
a
bc
d
e
1
3
2
FRControl ValveFlow Rate
armas.com.tr 35
Please submit following information to our sales department while ordering.
Maximum flow rate m³/hMaximum network/line pressure barMain line size mmValve connection type Maximum upstream pressure barDesired flow rate m³/h
Adjustment
Maintenance
• Start pump or open main valve of network and deliver water to system.• Open ball valve indicated with”b1”.• Bring 3-way selector on valve into “auto” position.• Adjustment bolt of pilot valve is factory adjusted. Do not make any processes with it. Consult us if valve does not perform regulation function
• Check finger filter indicated with “c” according to water quality and clean it. Do not make cleaning more than one within a few months unless water is too dirty.• Drain water within actuator and pilot valves of valves not used in winter.• Check downstream pressure value continuously.• Consult us if valve does not perform regulation function.
Pilot Valve Pressure Adjustment RangeStandard Differential Pressure Range 3 - 8 m 2 - 12 psi
Medium Differential Pressure Range 10 - 40 m 14 - 56 psi
High Differential Pressure Range 14 - 100 m 10 - 140 psi
Failure Causes Correcting/Repair
Valve not opening• 3-Way selector valve may be closed. • Line pressure may be low. • Upstream ball valve may be closed.
• Check 3-Way selector valve and bring it into “Auto” position. • Check valve upstream pressure and ensure necessary upstream pressure. • Open ball valve.
Valve not closing
• Diaphragm may be punctured. • Foreign substances may exist in diaphragm seat. • Connections of pilot valves may be clogged because of foreign substances •Finger filter may be clogged.
• Check diaphragm and replace with the new one if it is punctured. • Check diaphragm seat and remove foreign substances if any. • Check connections and clean.
• Clean if it is clogged.
Valve does not regulate
• Movable parts of differential float pilot valve may be clogged due to calcification. • Orifice plate used before valve may be mounted wrongly.
• Replace it with the new one.
• Ensure sealing between flanges and plate by mounting orifice plate according to sample mountage illustration.
Sample order form
Model Connection Size Control Feature Additional Features Options
67-67D
66-66D-64
63-63D
F: Flanged (ISO-ANSI)
TH: Threaed (BSPT-NPT)
VIC: Grooved End
2"-16"
1½"-3"
2"-4"
Flow Rate Control
NV: On/Off Speed Adjustment
PG: Pressure Gauge
EL: Electric Control
Position
Indicator
67 F 6" FR NV PIR
Order Information
Troubleshooting
armas.com.tr36
Description
Installation
Armaş “QR” model quick relief control valve is the safety control valve designed to protect system by releasing pressure surges to atmosphere quickly caused from sudden changes in water speed because pumps put into/out of service frequently in water network elevation lines. When network pressure goes beyond set point, valve opens by itself quickly and protects system by releasing over pressure. When line pressure decreases to normal level, it is closed slowly and automatically as wholly sealed without causing surge.
• Quick Pressure control valve is mounted on network in TE configuration.• Since valve's function is to release pressure, valve diameter may be selected as equal to or in closest smaller size than main pipe diameter. Valve diameter should be selected as smaller than main pipe diameter. Following empirical formula may be used in determining diameter of quick pressure relief control valve. Where;
• Valve closing time is proportional with pipe length. As system pipe length increases, valve closing time should be increased.
D=D = Diameter of quick pressure relief control valve in (mm)Q = System Flow Rate in (m3/h)Hm = System Operating Pressure (meter 1 bar ≈ 10 meter)
250xQHm
Typical Application
Pump
Quick Pressure Relief Valve
Check Valve
Isolation Valve (Gate, Butterfly Valve etc.)
1
2
3
4
Quick Pressure Relief Pilot Valve
Ball Valves
In-line Finger Filter
Pressure Gauge
Adjustment Bolt
a d
b
c
e
a
b1 b2c
d
e
1
3
4
2
Control ValveQuick Pressure Relief QR
armas.com.tr 37
Please submit following information to our sales department while ordering.
Maximum flow rate m³/hMaximum network/line pressure barMain line size mmValve connection type Maximum upstream pressure barDesired upstream pressure bar
Adjustment• Operate pump, open main valve on network and deliver water to the system.• Open ball valves indicated with “b1” and “b2”.• Wait for a while until water reach valve control chamber. When water reach control chamber, pressure gauge will show a certain pressure value.• Adjust desired upstream pressure value by means of adjustment bolt indicated with “e” on pilot valve indicated with “a” by referring pressure gauge.• When you turn adjustment bolt clockwise, upstream pressure value will increase and when you turn adjustment bolt counter-clockwise it will decrease.• After adjusting desired downstream pressure value, tighten contra nut below set screw. Pressure gauge will show upstream pressure value.
Pilot Valve Pressure Adjustment RangeStandard Pressure Range 5 - 160 m 7,5 - 240 psi
Medium Pressure Range 10 - 100 m 15 - 150 psi
High Pressure Range 5 - 240 m 7,5 - 360 psi
Failure Causes Correcting/Repair
Valve not opening
• Ball valves in valve downstream may be closed. • Valve upstream pressure may be too low. • Adjustment pressure of pilot valve may be higher than line pressure. • Needle valve on pilot valve may be closed.
• Check ball valves and open them if they are closed. • Check your system. • Decrease adjustment pressure in accordance with adjusting instruction by means of adjustment bolt. • Open needle valve one or two tours according to system adjustment
Valve not closing
• Diaphragm may be punctured. • Foreign substances may exist in diaphragm seat. • Connections of pilot valves may be clogged because of foreign substances • Finger filter may be clogged.
• Check diaphragm and replace with the new one if it is punctured. • Check diaphragm seat and remove foreign substances if any. • Check connections and clean.
• Clean if it is clogged.
Valve does not regulate
• Movable parts of differential float pilot valve may be clogged due to calcification. • Set point of needle valve on pilot valve may be wrong. • Pressure gauge may be failed.
• Replace it with the new one.
• Close needle valve fully and open it by 1 - 2 tours.
• Replace with new one.
Sample order form
Model Connection Size Control Feature Additional Features Options
67-67D
66-66D-64
63-63D
F: Flanged (ISO-ANSI)
TH: Threaed (BSPT-NPT)
VIC: Grooved End
2"-16"
1½"-3"
2"-4"
Quick PressureRelief
EL: Electric Control
SV-3: 3-Way Selector Valve
Position
Indicator
67 F 6" QR NV PIR
Order Information
Troubleshooting
armas.com.tr38
Description
Valve Sizing
Armaş “SA” model surge anticipating control valve is the safety control valve designed to protect system in relatively longer water supply network elevating line by damping energy waves formed by energy interruptions in pumping systems and by releasing water-hammers which are caused from sudden changes in water flow rate to atmosphere automatically and quickly. Valve is opened quickly by sensing diminished pressure wave previously by means of pressure signal tube it owned. When line pressure reached normal level, it is closed slowly and automatically as wholly sealed.
• Surge Anticipating valve is mounted on network in TE configuration. • Since valve's function is to release pressure, valve diameter may be selected as equal to or in closest smaller size than main pipe diameter. Valve diameter should be selected as smaller than main pipe diameter. Following empirical formula may be used in determining diameter of quick pressure relief control valve. Where;
• Valve closing time is proportional with pipe length. As system pipe length increases, valve closingtime should be increased.
D=D = Diameter of surge anticipating valve in (mm)Q = System Flow Rate (m3/h)Hm = System Operating Pressure (meter 1 bar ≈ 10 meter)
250xQHm
Low Pressure Pilot Valve
High Pressure Pilot Valve
Ball Valves
In-line Finger Filter
Pressure Gauge
Needle Valve
a d
b
c
e
f
a1
a
b
b2
b1
f
d
e
c2
c3
c4
c1
Control ValveSurge Anticipating SA
armas.com.tr 39
Installation• Mount valve in “TE” configuration.• Mount valve signal tube on main line.• Mount valve in direction of arrow indicated on it.• While connecting valve on line, place gasket between valve flange and pipe flange to ensure sealing and tighten the bolts as crosswise.• It is recommended that isolation valves (butterfly or gate valves etc.), air relief valve and strainer valves will be used in mounting valve on line (See the sample montage picture).
Pilot Valve Pressure Adjustment RangeStandard Pressure Range 5 - 160 m 7,5 - 240 psi
Medium Pressure Range 10 - 100 m 15 - 150 psi
High Pressure Range 5 - 240 m 7,5 - 360 psi
Typical Application
Pump
Pump Control Valve
Surge Anticipating Valve
1
2
3
1
3
2
armas.com.tr40
Control ValveSurge Anticipating SA
Adjustment
Adjusting High Pressure Pilot Valve• Loosen adjusting bolt (a1) of low pressure pilot valve indicated with “a” and tighten adjusting bolt (b1) of high pressure pilot valve indicated with “b”.•Start pump by closing ball valves indicated with c2 and c3.• When system pressure reached to operating pressure, open the valve indicated with “c3” and loosen “b1” adjusting bolt until water will drop from ball valve. After dropping water, turn the adjusting bolt as one turn in opposite direction and tighten the contra nut below it. In general, adjusting point of high pressure pilot valve is adjusted 1 bar above system pressure.• Open ”c2” ball valve and adjust low pressure pilot valve indicated with “a”.Adjusting Low Pressure Pilot Valve• Close ball valve indicated with “c4”.• Open needle valve indicated with “f” slowly.• Check the pressure by means of “e” pressure gauge. Pressure will decrease.• While decreasing pressure, water will drop from “c2” spherical valve.• After dropping water, close needle valve indicated with “f” and open “c4” ball valve.• If opening pressure of low pressure pilot valve indicated with “a” is not in desired value, adjust it to desired value by means of “a1” adjusting bolt. If low pressure wave (valve opening pressure) is too high, loosen “a1” adjusting screw as 1/2 turn. If low pressure wave is too low, tighten “a1” adjusting bolt as 1/2 turn. While adjusting each low pressure pilot valve, follow instructions given above.
Failure Causes Correcting/Repair
Valve not opening
• “c” ball valves on valve may be closed. • Low pressure pilot valve in not in the setting point. • Movable parts of pilot valves may be clogged due to calcification. • Needle valve of high pressure pilot valve may be closed.
• Check ball valves and open if they are closed. • Set low pressure pilot valve in accordance with adjusting instructions. • Replace with the new one.
• Open needle valve between 1 - 1/2 turn according to your system setting.
Valve not closing
• Diaphragm may be punctured. • Foreign substances may exist in diaphragm seat.• Connections of pilot valves may be clogged because of foreign substances • Finger filter may be clogged.
• Check diaphragm and replace with the new one if it is punctured. • Check diaphragm seat and remove foreign substances if any. • Check connections and clean.
• Clean if it is clogged.
Valve opens but does not close
• Low pressure pilot valve is not in desired setting.
• Readjust it in accordance with the instructions.
Troubleshooting
armas.com.tr 41
Sample order form
Model Connection Size Control Feature Additional Features Options
67-67D
66-66D-64
63-63D
F: Flanged (ISO-ANSI)
TH: Threaed (BSPT-NPT)
VIC: Grooved End
2"-16"
1½"-3"
2"-4"
Surge AnticipatingControl EL: Electric Control
Position
Indicator
67 F 6" SA EL PIR
Please submit following information to our sales department while ordering.
Maximum flow rate m3/hMaximum network/line pressure barMain line size mmValve connection type Maximum pump pressure barLength of main pipe line m
Order Information
armas.com.tr42
Description
Features
Adjustment
Armaş “HCV” model valve is hydraulically controlled check valve which operates with line pressure and prevents back-flow in system. When downstream pressure value exceeds upstream pressure value, valve is closed as wholly sealed without causing surge. When upstream pressure value exceeds downstream pressure value, check valve is opened by itself slowly. So it damps pressure surges formed during start-up.
• Opening-closing speed of check valve may easily be adjusted.• Valve may be operated by mounting it in vertical or horizontal position in system• Minimum opening pressure of valve is 0.7bar.
• Operate pump, open main valve on network and deliver water to the system.
Typical Application
Pump
Air Valve
Hydraulic Check Valve
1
2
3
In-line Finger Filter Pluga b
b a
1
2
3
Hydraulic Check HCV
armas.com.tr 43
Working Pressure Range bar (kg/cm2) psi (pound/inch2)
Standard 0,5-16 bar 7,5-240 psi
High Pressure (Optional) 0,5-25 bar 7,5-360 psi
Hydraulic Check Valve Sizing Table*
Valve Diameter Proposed IdealFlow Rate Valve Diameter Proposed Ideal
Flow Rate2” - 50 mm 15 m3/h 5” - 125 mm 100 m3/h
2 1/2”- 65 mm 24 m3/h 6” - 150 mm 130 m3/h
3” - 80 mm 36 m3/h 8” - 200 mm 225 m3/h
4” - 100 mm 56 m3/h 10” - 250 mm 350 m3/h
12” - 300 mm 510 m3/h
Failure Causes Correcting/Repair
Valve not opening • Line pressure may be low. • Check upstream pressure and ensure required upstream pressure.
Valve not closing• Diaphragm may be punctured. • Foreign substances may exist in diaphragm seat.• Finger filter may be clogged.
• Check diaphragm and replace with the new one if it is punctured. • Check diaphragm seat and remove foreign substances if any. • Clean if it is clogged.
* Recommended flow rate values for minimum head loss.
Sample order form
Model Connection Size Control Feature Additional Features Options
67-67D
66-66D-64
63-63D
F: Flanged (ISO-ANSI)
TH: Threaed (BSPT-NPT)
VIC: Grooved End
2"-16"
1½"-3"
2"-4"
HydraulicCheck Valve
PG: Pressure Gauge
SV-3: 3-Way Selector Valve
Position
Indicator
67 F 6" HCV PG PIR
Please submit following information to our sales department while ordering.
Maximum flow rate m3/hMaximum network/line pressure barMain line size mmValve connection type Maximum upstream pressure bar
Order Information
Troubleshooting
armas.com.tr44
Desricption
Features
Installation
Armaş “PC” model pump control valve is a control valve designed for putting booster type pumps into/out of service automatically which is used water network elevating lines. When start button is pressed, pump control valve is opened by itself slowly in comparison with booster pump until pump rotation will reach working rotation. When “stop” button is pressed, control valve is closed slowly without causing surge in the first plan. When pump control valve was closed as fully sealed, it is disengaged from system by means of “Limit Switch” on it. In situations like energy interruption, works as a check valve to prevent back-flow to pump and eliminates use of an extra check valve in the system.
• Pump control valve works synchronously with booster pump.• Control panel of pump control valve controls valve and pump together.• Opening-closing speed of valve may be adjusted easily.• Valve may be operated in mounting in horizontal and vertical positions in the system
• Make sure that valve is on a level with the pipeline while mounting it.• Mount valve in direction of arrow indicated on it.• While connecting valve on pipeline, place gasket between valve flange and pipe flange to ensure sealing and tighten the bolts as crosswise.• It is recommended that isolation valves (butterfly or gate valves etc.), air relief valve and strainer valves will be used in line-mounting of valve (see sample montage illustration).
Typical Application
Pump
Pump Control Valve
Surge Anticipating Valve
1
2
3
Solenoid Pilot Valve
Ball Valves
In-line Finger Filter
Limit Switch Assemble
Needle Valve
Check Valve
a d
b
c
e
f
f2
f1
a
b1
d
b2c1 c2
e
1 2
3
Control ValvePump (Booster) PC
armas.com.tr 45
Adjustment
Pump Control Valve Sizing Table*
• Connect pump control valve to pump panel according to electric schema of electric panel.• Open ball valve indicated with “b1” and “b2.• Valve will be opened slowly. When valve came to full open position, fixate the position of limit switch indicated with “d” according to full closed position of valve. Knob at the end of valve indicator should contact with Limit Switch.• Adjust valve opening speed by means of needle valve indicated with “e2” and valve closing speed by means of needle valve indicated with “e1”.
Valve Diameter Proposed IdealFlow Rate Vana Çapı Tavsiye Edilen İdeal
Akış Miktarı2” - 50 mm 15 m3/h 5” - 125 mm 100 m3/h
21/2” 65 mm 24 m3/h 6” - 150 mm 130 m3/h
3” - 80 mm 36 m3/h 8” - 200 mm 225 m3/h
4” - 100 mm 56 m3/h 10” - 250 mm 350 m3/h
12” - 300mm 510 m3/h
Failure Causes Correcting/Repair
Valve not opening
• Ball valve indicated with “c” on valve may be closed. • Solenoid Pilot valve coil may be burnt. • Needle valve may be closed.
• Check the ball valves and open them if they are closed. • Replace it with the new one. • Open needle valve according to valve opening speed.
Valve not closing
• Diaphragm may be punctured. • Foreign substances may exist in diaphragm seat. • Connections of valve control panel may be wrong. • Finger filter may be clogged.
• Check diaphragm and replace with the new one if it is punctured. • Check diaphragm seat and remove foreign substances if any. • Check connections and correct them according to electric schema.. • Clean if it is clogged.
Valve is closed butPump does not stop
• Position of Limit Switch may be wrong. • Connections of Limit Switch to control panel may be wrong.
• Readjust it according to instruction. • Check it and correct its connections
Sample order form
Model Connection Size Control Feature Additional Features
67-67D
66-66D-64
63-63D
F: Flanged (ISO-ANSI)
TH: Threaed (BSPT-NPT)
VIC: Grooved End
2"-16"
1½"-3"
2"-4"
Pump Control
PS: Pressure Sustaining
FR: Flow Rate Control
PG: Pressure Gauge
67 F 6" PC PG
* Recommended flow rate values for minimum head loss.
Please submit following information to our sales department while ordering.
Maximum flow rate m3/hMaximum network/line pressure barMain line size mmValve connection type
Order Information
Troubleshooting
armas.com.tr46
DescriptionArmaş “DPC” model deep-well pump control valve is a relief control valve designed for putting deep-well type pumps into/out of service automatically. Valve is connected on main line with a “TE” piece. Valve is in open position before pump operates. When pump starts up, valve is closed by itself slowly without causing surge and increases system pressure gradually. Before pump stops, valve opens by itself slowly and automatically and decreases system pressure gradually.
Valve Sizing•Deep-well Pump control valve is mounted on network in TE configuration since it is a electric activated release valve.•Since valve's function is to release, valve diameter may be selected as equal to or in closest smaller size than main pipe diameter. Valve diameter should be selected as smaller than main pipe diameter. Following empirical formula may be used in determining diameter of deep-well pump control valve. Where;
D=D = Diameter of deep-well pump control valve in (mm)Q = System Flow Rate in (m3/h)Hm = System Operating Pressure (meter 1 bar ≈ 10 meter)
250xQHm
Typical Application
Submersible Pump
Air Valve
Deep Well (Submersible) Pump Control Valve
Check Valve
Surge Anticipating Valve
Isolation Valve (Gate, Butterfly Valve etc.)
1
1
4
4 2
2
5
6
66 6
5
3
3
Solenoid Pilot Valve
Ball Valves
In-line Finger Filter
Limit Switch Assemble
Needle Valve
Plug
a e
b
c
d
f
a
f
d
c
e1
e2
b
Control ValveDeep Well (Submersible) Pump DPC
armas.com.tr 47
Adjustment
Maintenance
• Connect pump control valve to pump panel according to electric schema of electric panel.• Open ball valve indicated with “b”.• Valve will be opened slowly. When valve came to full open position, fixate the position of limit switch indicated with “d” according to full closed position of valve. Knob at the end of valve indicator should contact with Limit Switch.• Adjust valve opening speed by means of needle valve indicated with “e2” and valve closing speed by means of needle valve indicated with “e1”.
• Check finger filter indicated with “c” according to water quality and clean it. Do not make cleaning more than one within a few months unless water is too dirty.• Drain water within actuator and pilot valves of valves not used in winter.• Check downstream pressure value continuously.• Consult us if valve does not perform its regulating function.
Failure Causes Correcting/Repair
Valve not opening
• Ball valve indicated with “b” on valve may be closed. • Solenoid Pilot valve coil may be burnt. • Needle valve may be closed.
• Check the ball valves and open them if they are closed. • Replace it with the new one. • Open needle valve according to valve opening speed.
Valve not closing
• Diaphragm may be punctured. • Foreign substances may exist in diaphragm seat. • Valve’s Control panel may be connected incorrect. • Finger filter may be clogged.
• Check diaphragm and replace with the new one if it is punctured. • Check diaphragm seat and remove foreign substances if any. • Check connections and correct them according to electric schema..
• Clean if it is clogged.
Valve is closed butPump does not stop
• Position of Limit Switch may be wrong. • Connections of Limit Switch to control panel may be wrong.
• Readjust it according to instruction. • Check it and correct its connections
Sample order form
Model Connection Size Control Feature Additional Features
67-67D
66-66D-64
63-63D
F: Flanged (ISO-ANSI)
TH: Threaed (BSPT-NPT)
VIC: Grooved End
2"-16"
1½"-3"
2"-4"
Deep WellPump Control
QR: Quick Pressure Relief
PG: Pressure Gauge
67 F 6" DPC QR
Please submit following information to our sales department while ordering.
Maximum flow rate m3/hValve connection type Maximum network/line pressure barMaksimum pump pressure barDepth of the well m
Order Information
Troubleshooting
armas.com.tr48
Desciription
Working Principals
Technical Features
Backflushing control valves are the 3-way control valves which are operated by line pressure or an external pneumatic pressure. Valve works in filtration and back flushing mode as coordinated with filter elements in the system. Diaphragm-pilot valve assembly of valve works as bidirectional. While valve is switching into backflushing mode in filtration mode, pilot valve changes its way and opens relief way. It thereby prevents that fresh water is mixed with waste water and cleans filter elements in the best manner.
Working Pressure Standard 0,7 - 10 bar (10-145 psi)
TemperatureMin. Operation Temperature -10 ˚C (14 ˚F) DIN 2401/2
Max. Operation Temperature 80 ˚C (176 ˚F) DIN 2401/2
Connection
Flanged DIN 2501, ISO 7005 - 2
Threaded ISO (BSP), ANSI (NPT)
Grooved End Victaulic
CoatingStandard Polyester
Optional Epoxy
Model 38 Model 37
BFControl ValveBack Flushing
armas.com.tr 49
Available Models
Model 21 Diameter Connection Dimensions
2"x2"
Filter: 2” Threadedmm inch
L 195 7,8
Drainage: 2” Threaded
H 190 7,6
H1 100 4
Model 27 Diameter Connection Dimensions
4"x3"
Filter: 4” Flangedmm inch
L 295 11,6
Drainage: 3” Threaded
H 240 9,4
H1 125 5
Model 28 Diameter Connection Dimensions
4"x3"
Filter: 4” Grooved Endmm inch
L 270 10,6
Drainage: 3” Grooved End
H 240 9,4
H1 125 5
Model 37 Diameter Connection Dimensions
3"x2"
Filter: 3” Flangedmm inch
L 230 9
Drainage: 2” Threaded
H 138 5,4
H1 272,5 10,7
Model 38 Diameter Connection Dimensions
L
H1
H 3"x2"
Filter: 3” Grooved Endmm inch
L 230 9
Drainage: 2” Threaded
H 138 5,4
H1 272,5 10,7
armas.com.tr50
BFControl ValveBack Flushing
Main Parts
Part Name Material
Body Cast Iron GG 25
Cover Cast Iron GG 25
Diaphragm Nylon Reinforced Natural Rubber
Stem Stainless Steel SST 304
Spring Thrust Ring Polyamide
Spring Stainless Steel SST 302
Bolt, Nut Coated Steel SST
Sealing Seat Bronze
Sealing Gaskets EPDM, Natural Rubber
Typical Application
Controller
Back-Flushing Valve
Disc Filter
Kinetic Air Valve
1
1
4
2
3
2
3
4
armas.com.tr 51
Head Loss Charts
2"x2” Head Loss Chart
1
1
1
20
20
30
30
60 80 10040
40 60 80 100
2
2
23
3
34
4
45
5
56
6
67
7
78
8
8
3"x2” Head Loss Chart
4"x3” Head Loss Chart
Backflushing Mode Filtration Mode Backflushing Mode Filtration Mode
Backflushing Mode Filtration Mode
Hea
d L
oss (
mSS
)H
ead
Los
s (m
SS)
Hea
d L
oss (
mSS
)
Flow Rate (m3/h)
Flow Rate (m3/h) Flow Rate (m3/h)