Argelite - Horizontal Systems

9
 New A RGE LITE  -Horizontal-System  For decades, ARGETON is standing for high-quality terracotta façade tiles that are used on both architecturally sophisticated buildings and renovations with great success. In addition to the well-known double skin tiles, ARGELITE façade tiles represent a thinner and lighter option with an easier and time saving installation method for both, new erected buildings as well as r enovation issues, also on single family houses.  A joint research programme with Wienerberger Fran ce brought out the new  ARGELITE-H-System, which has been firstly realised successfully in the practice on a project in Metz (France). The ARGELITE-H-System substructure consists of horizontal aluminium carrier rails. EPDM- distance pieces keep the tiles in position and guarantee a 4mm vertical joint. The tiles can be installed into the carrier rails in a very easy way, whereas aluminium clips or joint profiles are not necessary for this system.  ARGELITE tiles are available in lengths up to 800mm, for heights of 200, 250 or 300mm in all natural colours and glazed surfaces.

Transcript of Argelite - Horizontal Systems

Page 1: Argelite - Horizontal Systems

7/22/2019 Argelite - Horizontal Systems

http://slidepdf.com/reader/full/argelite-horizontal-systems 1/9

 New ARGELITE

 -Horizontal-System

 

For decades, ARGETON is standing for high-quality terracotta façade tiles that are used

on both architecturally sophisticated buildings and renovations with great success.

In addition to the well-known double skin tiles, ARGELITE façade tiles represent a thinnerand lighter option with an easier and time saving installation method for both, new erectedbuildings as well as renovation issues, also on single family houses.

 A joint research programme with Wienerberger France brought out the new ARGELITE-H-System, which has been firstly realised successfully in the practice on aproject in Metz (France).

The ARGELITE-H-System substructure consistsof horizontal aluminium carrier rails. EPDM-distance pieces keep the tiles in position andguarantee a 4mm vertical joint.

The tiles can be installed into the carrier rails

in a very easy way, whereas aluminium clipsor joint profiles are not necessary for thissystem.

 ARGELITE tiles are available inlengths up to 800mm,for heights of 200, 250 or 300mmin all natural colours and glazedsurfaces.

Page 2: Argelite - Horizontal Systems

7/22/2019 Argelite - Horizontal Systems

http://slidepdf.com/reader/full/argelite-horizontal-systems 2/9

 

 Advantages of the system at a glance:

- For renovations, thermal retrofitting and newbuildings, also for single family houses

- Time and cost saving installation

- Tiles can be cut horizontally or vertically,direct on the building site which allowshigh variability

- The façade can be installed from top tobottom and vice versa to avoid damagesduring the construction time enablinggreat flexibility

- Due to the geometry of the tiles no specialbottom or top aluminium rails are needed

- Particularly suitable for renovationsbecause of the low weight system of approx.31 kg/m²

- Installations of building corners orwindows are much easier than for examplewith an aluminium hook rail

- For all current insulation sizes(0cm – 30cm)

- Minimized heat bridgesdue to thermal separations

- Low-energy houses and passive housesare realisable

First pro ject realised with the new ARGELITE-Hor izontal-System:

Office building in Metz, FranceMay, 2011 

Page 3: Argelite - Horizontal Systems

7/22/2019 Argelite - Horizontal Systems

http://slidepdf.com/reader/full/argelite-horizontal-systems 3/9

Page 4: Argelite - Horizontal Systems

7/22/2019 Argelite - Horizontal Systems

http://slidepdf.com/reader/full/argelite-horizontal-systems 4/9

Page 5: Argelite - Horizontal Systems

7/22/2019 Argelite - Horizontal Systems

http://slidepdf.com/reader/full/argelite-horizontal-systems 5/9

Page 6: Argelite - Horizontal Systems

7/22/2019 Argelite - Horizontal Systems

http://slidepdf.com/reader/full/argelite-horizontal-systems 6/9

Page 7: Argelite - Horizontal Systems

7/22/2019 Argelite - Horizontal Systems

http://slidepdf.com/reader/full/argelite-horizontal-systems 7/9

Page 8: Argelite - Horizontal Systems

7/22/2019 Argelite - Horizontal Systems

http://slidepdf.com/reader/full/argelite-horizontal-systems 8/9

 

Technical Data - ARGELITE

sizes length: max. l = 800 mm (centre to centre distance) tolerance ± 1,0 mm

height: 200 / 250 / 300 mm (centre to centre distance)tolerance ± 2,0 mm

thickness: 24 mmtolerance ± 1,0 mm

constancy ofthe form:  wingity: ±0,25 % of the diagonal(DIN EN 1304) camber: ±0,25 % of the length/heigh

evenness: ±0,25 % of the length±0,70 % of the height

 Angularity: height ≤ 300 mm ±1,0 mm

weight (dry): ca. 30 kg/m²

body density:  ≥ 2,0 g/cm³

breaking load: average value ≥ 1,5 kN / minimum value ≥ 1,2 kN(DIN EN 1304)

bending tensile 12-20 N/mm²strength: 

water absorption:  ≤ 9,0 %(DIN EN 539-2) according to test reports of Bautest Dresden GmbH (formerly MPA

Dresden) between 3 and 8 %.

frost resistance:  according to DIN EN 539-2(DIN EN 539-2)

linear thermal  < 0.4 mm referring to a length of 1000mmexpansion: (EN ISO 10545-8)

moisture expansion:  = 0,03% (according to test reports of Bautest Dresden GmbH)(DIN EN 10545-10)

acid-resistance:  proven (according to test reports of Bautest Dresden GmbH)(DIN EN 10545-13)

alkali-resistance:  proven (according to test reports of Bautest Dresden GmbH)(DIN EN 10545-13)

Page 9: Argelite - Horizontal Systems

7/22/2019 Argelite - Horizontal Systems

http://slidepdf.com/reader/full/argelite-horizontal-systems 9/9

 

fire protection ceramic tile plates: flammability rating A, incombustible classification:  aluminium substructure: flammability rating A1, incombustible(DIN 4102)

composition of clay:  calcsparpotashquartzfeldspathaluminium oxideferric oxidemanganese

chromium oxideplatinum

external control:  Bautest Dresden GmbH (formerly MPA Dresden); approved testinglaboratory, regulatory agency and certificate authority