Architype - Delivering Radical Low Energy Performance with BIM
-
Upload
elrond-burrell -
Category
Design
-
view
744 -
download
1
description
Transcript of Architype - Delivering Radical Low Energy Performance with BIM
![Page 1: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/1.jpg)
Delivering!Radical!Low Energy!Performance!with BIM
![Page 2: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/2.jpg)
Be Social #NBSLive #BIM #Sustainability #Passivhaus @ElrondBurrell @ArchitypeUK
![Page 3: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/3.jpg)
We design
Life Enhancing
Sustainable Architecture That Works
![Page 4: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/4.jpg)
Overview BIM Passivhaus BIM + Passivhaus BIM 4 Passivhaus Outcomes
![Page 5: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/5.jpg)
BIM “Building Information Modeling (BIM) is the process of generating and managing information about a built asset over its whole life.” Cabinet Office 2012
![Page 6: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/6.jpg)
BIM A quality assurance delivery strategy to provide the right information at the right point in the process
![Page 7: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/7.jpg)
Passivhaus “…the world’s leading standard in energy efficient design” Optimal Comfort (ISO 7730) Minimum Energy
![Page 8: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/8.jpg)
PHPP “simplified models, precise data” Accurate Open Parametric Instant
![Page 9: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/9.jpg)
Passivhaus A quality assurance standard that ensure that the right information is used at the right point in the process to deliver reliable energy performance & comfort.
![Page 10: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/10.jpg)
BIM + Passivhaus Process + Information + Model and test
- Not box ticking - Not sexy graphics - Not on site
![Page 11: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/11.jpg)
BIM 4 Passivhaus Simple + Useful + Productive
1. Visual interrogation 2. Accurate Live Numerical Data
![Page 12: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/12.jpg)
Visual Interrogation Design coordination / integration Thermal Continuity Heat Loss Envelope
![Page 13: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/13.jpg)
Design Coordination
![Page 14: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/14.jpg)
Design Coordination
![Page 15: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/15.jpg)
Thermal Continuity
![Page 16: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/16.jpg)
Heat Loss Envelope
![Page 17: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/17.jpg)
Accurate Live Numerical Data Treated Floor Area (TFA) Actual Volumes Ventilation Volumes Heat Loss Areas Window / Door Opening Areas
![Page 18: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/18.jpg)
Areas and Volumes
![Page 19: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/19.jpg)
Heat Loss Areas
![Page 20: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/20.jpg)
Opening Areas
![Page 21: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/21.jpg)
Outcomes 2 x 65kW Boilers for a 2200m2 School 25kW peak heat demand = 5x oversized! 90% reduction in gas consumption
![Page 22: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/22.jpg)
![Page 23: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/23.jpg)
Fresh Indoor Air
![Page 24: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/24.jpg)
“We feel that our children are more alert and attentive in lessons due to the amount of daylight in classrooms and the fresh air throughout the school ... learning has been enhanced” Sara Morris, Head Teacher
![Page 25: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/25.jpg)
![Page 26: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/26.jpg)
![Page 27: Architype - Delivering Radical Low Energy Performance with BIM](https://reader033.fdocuments.in/reader033/viewer/2022060118/558a145dd8b42aab588b46ce/html5/thumbnails/27.jpg)
Conclusion Use BIM to support the Passivhaus design process People design sustainable buildings not software!