ARCHITECT: TK BUILDING ISSUED FOR BID & PERMIT JUNE 18,...

16
ARCHITECTURAL CIVIL STRUCTURAL MEP 600 Parsippany Road Suite 301 Parsippany, NJ 07054 973.796.0695 Dewberry Engineers, Inc. 5177 Richmond Avenue Suite 670 Houston, TX 77056 713.664.0130 www.matrixstructural.com Matrix Structural 10260 Westheimer Rd. Suite 250 Houston, TX 77042 713.429.4949 www.infinitymep.com Infinity MEP Consultants ISSUED FOR BID & PERMIT JUNE 18, 2021 TK BUILDING 10010 BAYPORT BLVD, PASADENA, TX, 77507 5051 Westheimer Rd Suite 320 Houston, TX 77056 713.621.8714 www.dewberry.com Dewberry Architects, Inc. HALDOR TOPSOE www.dewberry.com

Transcript of ARCHITECT: TK BUILDING ISSUED FOR BID & PERMIT JUNE 18,...

Page 1: ARCHITECT: TK BUILDING ISSUED FOR BID & PERMIT JUNE 18, …c-air-s.com/plans/haldor_topsoe_mech_dwgs.pdf · gb-01 1 scale: view name 1/8" = 1'-0" 1/a101 1 a101 sim callout building/wall

ARCHITECTURAL CIVIL STRUCTURAL MEP

600 Parsippany RoadSuite 301Parsippany, NJ 07054

973.796.0695

Dewberry Engineers, Inc.5177 Richmond Avenue Suite 670Houston, TX 77056

713.664.0130www.matrixstructural.com

Matrix Structural 10260 Westheimer Rd.Suite 250Houston, TX 77042

713.429.4949www.infinitymep.com

Infinity MEP Consultants

ISSUED FOR BID & PERMITJUNE 18, 2021

FOR REVIEW ONLY 02/25/2021

NOT FOR REGULATORY APPROVAL PERMITTING, OR CONSTRUCTION

ARCHITECT: Dustin O'Brien, AIA Texas Registration No. 20189

TK BUILDING10010 BAYPORT BLVD, PASADENA, TX, 77507

5051 Westheimer RdSuite 320Houston, TX 77056

713.621.8714www.dewberry.com

Dewberry Architects, Inc.

HALDOR TOPSOE

www.dewberry.com

Page 2: ARCHITECT: TK BUILDING ISSUED FOR BID & PERMIT JUNE 18, …c-air-s.com/plans/haldor_topsoe_mech_dwgs.pdf · gb-01 1 scale: view name 1/8" = 1'-0" 1/a101 1 a101 sim callout building/wall

A101

1SIM

101

APC-X

8' - 0"

A

X#XX 1HR

SF01

Area Name

150 SF

FIRST FLOOR

100' - 0"

1

PT-XRB-X

CPT-X

NOTES: 22

101

ROOM NAME

ROOMNAME

101

1

A101

SIM

GB-01

Scale:1

View Name1/8" = 1'-0" 1/A101

1

A101

SIM

CALLOUT

BUILDING/WALLSECTION

DETAIL SECTION

ROOM TAG

ROOM FINISHTAG

CEILING TAG

DOOR / BORROWED LITE TAG

WINDOW TAG

WALL TAG

FURNITURE, CASEWORK, & EQUIPMENT TAG

REVISION TAG

KEYNOTE TAG00 00 00.A1

AREA TO BE ENLARGED SHEET REF.

PLAN / DETAIL REF.

SECTION REF.

SHEET REF.

DETAIL REF.

SHEET REF.

LEVEL LINE

AREA SQUARE FOOTAGE

ROOM NUMBER

EXTERIOR ELEVATION

INTERIOR ELEVATION

ELEVATION REF.

SHEET REF. A101

A101

1ELEVATION REF.

SHEET REF.

VIEW NAME

VIEW SCALE

VIEW DESIGNATION

VIEW REF/SHEET REF WHERE VIEW IS REFERENCED

VIEW TITLE

WALL FINISH

BASE FINISH

FLOOR FINISH

AREA TAG

CEILING TYPE

CEILING HEIGHT (ABOVE FINISH FLOOR)

LEVEL NAME

LEVEL ELEVATION

GRID LINE

NORTH INDICATOR

GRID NUMBER OR LETTER

INDICATES PLAN NORTH

INDICATES TRUE NORTH

A101

1

SPOT ELEVATION SYMBOL

NOTES (AS NEEDED)

ROOM NUMBER

NEW DOOR EXISTING DOOR EXISTING DOORTO BE DEMOLISHED

WALL MOUNTED LAVATORY

FLOOR MOUNTEDWATER CLOSET

WALL MOUNTED TANKLESS WATER

CLOSET

COUNTER MOUNTED LAVATORY

FLOOR MOUNTED TANKLESS WATER

CLOSET

ELECTRIC WATER COOLER

TOILET PARTITIONS

LOCKERS

SINGLE

DOUBLE

TRIPLE

QUAD

GRAB BARWALL MOUNTED URINAL

FINISH WALL SURFACES OR CEILING HUNG PARTITION

MOUNTING HEIGHT NOTES:

1. PROVIDE BLOCKING AS REQUIRED FOR MOUNTING ACCESSORIES2. EQUIPMENT SHOWN IN THE MOUNTING HEIGHT LEGEND MAY OR MAY NOT BE USED IN THE CONSTRUCTION OF THIS

PROJECT. THE ABOVE LEGEND REPRESENTS A MASTER LIST OF TYPICAL EQUIPMENT COMPILED BY THE ARCHITECT.3. MOUNT EQUIPMENT AT HEIGHTS INDICATED UNLESS OTHERWISE NOTED4. REFER TO THE TOILET AND BATH ACCESSORIES SCHEDULE IN THE SPECIFICATIONS.5. COMPLIANCE WITH ADA FOR INSTALLATION OF ALL THE ACCESSORIES AND EQUIPMENT IS RESPONSIBILITY OF THE G.C.

AF

F

17"-

19"

18" TO FINISH FACE OF WALL OR PARTITION AT ACCESSIBLE WATER CLOSETS

WATER CLOSET

13

3"-

36

" A

FF

18"

MIN

39"-

41

" A

FF

MAX.

12" 42" MIN

54" MIN

39"- 41"

X

42" GRAB BAR

24" 12" 6" MAX

42" MIN

X

ONE PIECE 36" GRAB BAR W/ USE OF

CONCEALED FLUSH VALVE

FINISH WALL SURFACES OR CEILING HUNG PARTITION

30"

MA

X

24" 12" 6" MAX

42" MIN

33"-

36

" A

FF

FINISH WALL SURFACES OR CEILING HUNG PARTITION

33"-

36

" A

FF

21" 6" 9" 6" MAX

42" MIN

33"-

36

" A

FF

X

ONE PIECE 36" GRAB BAR W/ USE OF

REVEALED FLUSH VALVE

X

TWO PIECE 36" GRAB BAR W/ USE OF

REVEALED FLUSH VALVE

7"- 9"

15"

MIN

1 1

/2"

MIN

X

JUMBO ROLL TOILET PAPER HOLDER

NOTE: INSULATE EXPOSED HOT WATER & DRAIN PIPES

TO

LIP

OF

SIN

K

34"

MA

X A

FF

27"

MIN

17"- 25"

8" MIN

9"

MIN

11" MIN

X

ACCESSIBLE LAVATORY OR SURFACE MOUNTED

COUNTERTOP SINK

MOP RACK

X

FIRE EXTINGUISHER

CABINET

X

FIRE EXTINGUISHER

X

COAT HOOK

X

48"

MA

X A

FF

48"

MA

X A

FF

48"

MA

X A

FF

4' -

0"

WALL TO WALL

18"

54"

22"

AF

F

FILM BACKED GLASS MIRROR

X

FULL LENGTH MIRROR

X

AS

NO

TE

D

BOTTOM EDGE OF REFLECTIVE SURFACE

40"

MA

X A

FF

76"

MIN

AF

F

MIN

1' - 8"

X

ACCESS MIRROR

X

SANITARY NAPKIN / TAMPON VENDOR

48"

MA

X A

FF

48"

MA

X

X

FULL HEIGHT PAPER TOWEL DISPENSER /

RECEPTACLE

X

PAPER TOWEL DISPENSER

ROBE HOOK

X

3"

3"

3"

(48"

MA

X A

FF

@ A

DA

)

66"

48"

MA

X

ELEVATOR CALL BUTTON

X

42"

AF

F

AS

NO

TE

D

X

COUNTERTOP MOUNTED SOAP DISPENSER

(48"

MA

X A

FF

)

40"

X

SURFACE MOUNTED SOAP DISPENSER

LIGHT SWITCH

X

FIRE PULL

X

VISUAL ALARM

X

CONVENIENCE OUTLET (U.N.O.)

X

48"

MA

X A

FF

48"

MA

X A

FF

80"

MA

X A

FF

AF

F1

5"

MIN

DASHED LINES INDICATE REQUIRED KNEE CLEARANCE

48"

MA

X A

FF

24"

AF

F

X

URINAL

17"

MA

X A

FF

44"

MA

X A

FF

X

ACCESSIBLE URINAL

X

NAPKIN DISPOSAL -SURFACE MOUNTED

3"

4"

HAND DRYER

X

UN

OB

ST

RU

CT

ED

48"

MA

X A

FF

SID

E R

EA

CH

)

(IN

IL

: 5

4"

MA

X A

FF

SID

E R

EA

CH

46"

MA

X A

FF

OV

ER

OB

ST

RU

CT

ION

RECESSED SOAP DISH

X

(48"

MA

X A

FF

)

40"

6

A

54321

B

C

D

E

F

SCALE

APPROVED BY

CHECKED BY

SHEET NO.

TITLE

DRAWN BY

DATE

PROJECT NO.

REVISIONS

SEAL

10260 Westheimer Rd. Suite 250 Houston, TX 77042713.429.4949

Infinity MEP Consultants

Matrix Structural

5177 Richmond Avenue Suite 670 Houston, TX 77056713.664.0130

600 Parsippany Rd Suite 301Parsippany, NJ 07054713.576.0148

Dewberry Engineers Inc.

ISSUE FOR BID & PERMIT

A B

KEY PLAN

6/1

8/2

021 4

:21

:06

PM

GENERALINFORMATION

AND INDEX

Author

Checker

Approver

06/18/2021

50132460

TK

BU

ILD

ING

HA

LD

OR

TO

PS

OE

100

10

BA

YP

OR

T B

LV

D,

PA

SA

DE

NA

, T

X,

775

07

Dewberry Architects, Inc.

5051 Westheimer RdSuite 320Houston, TX 77056713.621.8714

G-001

AB ANCHOR BOLTACST ACOUSTIC(AL)ADDL ADDITIONALADDN ADDITIONADH ADHESIVEADJ ADJACENT, ADJOINING,

ADJUSTABLEAED AUTOMATED EXTERNAL

DEFIBRILLATORAFF ABOVE FINISH FLOORALT ALTERNATEALUM ALUMINUMANCH ANCHORANOD ANODIZE(D)AP ACCESS PANELAPC ACOUSTICAL PANEL CEILINGAPPROX APPROXIMATEASPH ASPHALTAUTO AUTOMATICAVE AVERAGEAWT ACOUSTICAL WALL TREATMENT

BAL SHT BALANCE SHEETBC BRICK COLORBCS BABY CHANGING STATIONBD BOARDBG BUMPER GUARDBITUM BITUMINOUSBLDG BUILDINGBLKG BLOCKING (WOOD)BOT BOTTOMBRDG BRIDGINGBRG BEARINGBRK PV BRICK PAVERSBRKT BRACKETBSMT BASEMENTBTWN BETWEENBUR BUILT UP ROOFING

CAB CABINETCB CHALKBOARDCC CUBICLE CURTAINCCT CUBICLE CURTAIN TRACKCFCI CONTRACTOR FURNISHED

CONTRACTOR INSTALLEDCFMF COLD-FORMED METAL FRAMINGCG CORNER GUARDCH COAT HOOKCIP CONC CAST-IN-PLACE CONCRETECJ CONTROL JOING, CONSTRUCTION

JOINTCLG CEILINGCLR CLEARCMU CONCRETE MASONRY UNITCNTR COUNTERCO CLEAN OUT, CASED OPENINGCOL COLUMNCOMB COMBINATION, COMBINEDCOMP COMPRESSIBLECOMPT COMPARTMENTCONC CONCRETECONC CTG CONCRETE COATINGCOND CONDITIONCONT CONTINUOUSCONTR CONTRACTORCORR CORRIDORCPRS COMPRESSIBLECPT CARPETCR CLOSET RODCRL CRASH RAILCRS COLD-ROLLED STEELCTR CENTER(S)CUH CABINET UNIT HEATERCUV CABINET UNIT VENTILATORCW CURTAINWALL

D DEEP, DEPTH, PENNY NAILDC DISPLAY CASEDET DETAILDETN DETENTIONDF DRINKING FOUNTAINDIA DIAMETERDIM DIMENSIONDN DOWNDP DECORATIVE PANELDR DOORDS DOWNSPOUTDWG DRAWING(S)

EHD ELECTRIC HAND DRYEREJ EXPANSION JOINTEL ELEVATIONELEC ELECTRIC, ELECTRICALELEV ELEVATOREMBED EMBEDMENTEMER EMERGENCYEPDM ETHYLENE PROPYLENE DIENE

MONOMEREQ EQUALEQUIP EQUIPMENTES EXPOSED STRUCTUREETR EXISTING TO REMAINEW EACH WAYEWC ELECTRIC WATER COOLEREWH ELECTRIC WATER HEATEREXIST EXISTINGEXP EXPANSIONEXT EXTERIOR

FAB FABRICFD FLOOR DRAINFDTN FOUNDATIONFE FIRE EXTINGUISHERFEC FIRE EXTINGUISHER CABINETFF FINISH FLOORFHC FIRE HOSE CABINETFIN FINISHFLASH FLASHINGFLP FLOOR PATTERN

FLR FLOORFRP FIBER REINFORCED PLASTICFTG FOOTINGFURG C FURRING CHANNELFURN FURNACEFWC FABRIC WALLCOVERING

GA GAGE, GAUGEGALV GALVANIZEDGB GRAB BARGFRC GLASS-FIBER REINFORCED

CONCRETEGL GLASSGL BLK GLASS BLOCKGLZ CMU GLAZED CONCRETE MASONRY UNITGRFG GLASS-FIBER REINFORCED GYPSUMGT GROUTGWH GAS FIRED WATER HEATERGYP BD GYPSUM WALL BOARD

H HIGH, HATCH (ROOF)HB HOSE BIBHDNR HARDENERHDW HARDWAREHDWD HARDWOODHM HOLLOW METALHORIZ HORIZONTALHR HANDRAILHT HEIGHTHTG HEATINGHVAC HEATING, VENTILATING, AND AIR

CONDITIONING

ID INSIDE DIAMETER, INSIDE DIMENSION

IF INSIDE FACEINCL INCLUDEDINSUL INSULATIONINT INTERIORINV INVERT

JT JOINT

KD KNOCKED DOWNKOP KNOCK OUT PANEL

L LONG, ANGLELAM LAMINATE(D)LAV LAVATORYLH LEFT HANDLINO LINOLEUMLKR LOCKERLL LIVE LOAD, LOW LEVELLLH LONG LEG HORIZONTALLLV LONG LEG VERTICALLT LIGHTLVL LEVELLVR LOUVER

MAS MASONRYMATL MATERIALMAX MAXIMUMMB MARKERBOARDMBH MOB/BROOM HOLDERMECH MECHANICALMED MEDIUMMEZZ MEZZANINEMFR MANUFACTURERMH MANHOLEMI MIRRORMIN MINIMUM, MINUTEMISC MISCELLANEOUSMO MASONRY OPENINGMOD MODEL, MODULE, MODULARMSB MOP SERVICE BASINMT MOUNTMTL METAL

NDU NEEDLE DISPOSAL UNITNIC NOT IN CONTRACT, NOISE ISOLATION

CLASSNO NUMBERNOM NOMINALNTS NOT TO SCALE

OA OVERALLOC ON CENTEROD OUTSIDE DIAMETER, OUTSIDE

DIMENSIONOF OUTSIDE FACEOFCI OWNER FURNISHED CONTRACTOR

INSTALLEDOFD OVERFLOW DRAINOFOI OWNER FURNISHED OWNER

INSTALLEDOH OVERHEADOH DR OVERHEAD DOOROP OPERABLE PARTITIONOPH OPPOSITE HANDOPNG OPENINGOPP OPPOSITE OS OVERFLOW SCUPPER

PC PORTLAND CEMENT, POINT OF CURVE, POLYCARBONATE

PCC PRECAST CONCRETEPERIM PERIMETERPJ PROJECTORPL PLATE, PLASTIC LAMINATEPLAS PLASTERPLBG PLUMBINGPLYWD PLYWOODPS PROJECTION SCREENPSF POUNDS PER SQUARE FOOTPT PAINTPTD PAPER TOWEL DISPENSERPTDR PAPER TOWEL DISPENSER &

RECEPTACLEPTN PARTITION

PTR PAPER TOWEL RECEPTACLEPVC POLYVINYL CHLORIDEPVG PAVING

R RISER, RADIUS, THERMAL RESISTANCE (R-VALUE)

RB RESILIENT BASERCP REFLECTED CEILING PLANRD ROOF DRAIN, ROADREF REFERENCE, REFRIGERATORREINF REINFORCEREQD REQUIREDRF RESILIENT FLOORINGRFG ROOFINGRFM REMOVABLE FLOOR MATRH RIGHT HANDRO ROUGH OPENINGRSF RESINOUS FLOORINGRST REINFORCING STEELRTF RESILIENT TILE FLOORINGRV ROOF VENT, ROOF VENTILATOR

SC SEALED CONCRETESCHED SCHEDULESCR SHOWER CURTAIN RODSCWD SOLID CORE WOOD DOORSD SOAD DISPENSERSECT SECTIONSF STOREFRONTSH SHINGLES, SINGLE HUNG (WINDOW)SHT SHEETSHTHG SHEATHINGSHV SHELVINGSLNT SEALANTSND SANITARY NAPKIN DISPENSERSNDU SANITARY NAPKIN DISPOSAL UNITSOG SLAB ON GRADESPCG SPACINGSPEC SPECIFICATIONSPKR SPEAKERSQ SQUARESS SERVICE SINK , SOLID SURFACINGSST STAINLESS STEEL, SHOWER SEATSTD STANDARDSTL STEELSTL JST STEEL JOISTSTL LNTL STEEL LINTELSTL PL STEEL PLATESTL RF DK STEEL ROOF DECKSTL TR STEEL TRUSSSTN STAINSTRUCT STRUCTURALSUSP SUSPENDSV SHEET VINYLSWP SHEET WALL PROTECTIONSYMM SYMMETRICALSYNTH SYNTHETIC

T TILE, TREADT&G TONGUE AND GROOVET/S TUB/SHOWERTB TOWEL BAR, TACKBOARDTC TOILET COMPARTMENTTD TRENCH DRAINTER TERRAZZOTHK THICKTOB TOP OF BEAMTOC TOP OF CONCRETE, TOP OF CURBTOF TOP OF FOOTINGTOM TOP OF MASONRYTOS TOP OF SLAB, TOP OF STEELTOW TOP OF WALLTPH TOILET PAPER HOLDERTR TOWEL RACKTS TUBE STEEL, TRANSITION STRIP

UNO UNLESS NOTED OTHERWISE

VCT VINYL COMPOSITION TILEVERT VERTICALVIF VERIFY IN FIELDVWC VINYL WALL COVERING

W WIDE, WESTWC WALL COVERINGWD WOOD, WOOD DOORWDW WINDOWWP WALL PATTERN, WATERPROOFINGWT WEIGHT, WINDOW TREATMENTWWF WELDED WIRE FABRIC

STANDARD ABBREVIATIONS

STANDARD DETAILING SYMBOLS

STANDARD DRAFTING SYMBOLS

SHEET INDEX

SHEET NO. SHEET NAME

GENERAL

000 COVER

G-004 HARRIS COUNTY FIRE CODE REVIEW SHEET

G-001 GENERAL INFORMATION AND INDEX

G-002 CODE ANALYSIS AND LIFE SAFETY PLAN

G-003 PROPOSED CONSTRUCTION PHASING

CIVIL

C-001 COVER SHEET

C-101 EXISTING CONDITIONS PLAN

C-102 DEMOLITON PLAN

C-103 SITE PLAN

C -104 GRADING AND DRAINAGE PLAN

C-105 UTILITY PLAN

C-106a STORMWATER POLLUTION PREVENTION PLAN

C-106b STORMWATER POLLUTION PREVENTION PLAN WORK FORM

C-107 LIGHTING PLAN

C-108 VEHICLE MOVEMENT PLAN

C-109 STORMWATER POLLUTION PREVENTION PLAN DETAILS

C-110 CONSTRUCTION DETAILS

C-111 CONSTRUCTION DETAILS

C-112 CONSTRUCTION DETAILS

C-113 HARRIS COUNTY FLOOD CONTROL DISTRICT REVIEW SHEET

C-114 HARRIS COUNTY ENGINEERING DEPARTMENT REVIEW SHEET

ARCHITECTURAL

A-100 CAMPUS - SITE PLAN

A-101 ENLARGED SITE PLAN AND ROOF PLAN

A-102 PLINTH PLAN

A-110 FIRST FLOOR OVERALL FLOOR PLAN

A-111A FIRST FLOOR ANNOTATION PLAN - AREA A

A-111B FIRST FLOOR ANNOTATION PLAN - AREA B

A-112A FIRST FLOOR POWER, DATA, & EQUIPMENT PLAN - AREA A

A-112B FIRST FLOOR POWER, DATA & EQUIP. PLAN & SCHED. - AREA B

A-113A FIRST FLOOR RCP - UNDER PLATFORM AND CANOPY

A-113B FIRST FLOOR OVERALL REFLECTED CELIING PLAN

A-114 FIRST FLOOR FINISH PLAN AND SCHEDULE

A-120 EQUIPMENT PLATFORM AND POWER PLAN

A-130 ROOF PLAN

A-201 EXTERIOR ELEVATIONS

A-202 ENLARGED ELEVATIONS

A-301 BUILDING SECTIONS

A-302 BUILDING SECTIONS

A-303 BUILDING SECTIONS

A-311 WALL SECTIONS

A-312 WALL SECTIONS

A-313 WALL SECTIONS

A-314 WALL SECTIONS

A-315 WALL SECTIONS

A-401 ENLARGED FLOOR PLANS AND ACCESSORY SCHEDULE

A-402 ENLARGED FLOOR PLANS

A-411 LARGE SCALE ELEVATION DETAILS

A-501 EXTERIOR PLAN DETAILS

A-502 EXTERIOR PLAN DETAILS

A-503 EXTERIOR SECTION DETAILS

A-504 EXTERIOR SECTION DETAILS

A-505 EXTERIOR SECTION DETAILS

A-531 ROOF DETAILS

A-601 DOOR SCHEDULES, ELEVATIONS, AND DETAILS

A-631 WALL PARTITIONS, ASSEMBLIES, AND DETAILS

A-632 WALL PARTITIONS, ASSEMBLIES, AND DETAILS

A-701 INTERIOR ELEVATIONS

A-702 INTERIOR ELEVATIONS

A-703 INTERIOR ELEVATIONS

A-720 MILLWORK DETAILS

A-722 MILLWORK DETAILS

STRUCTURAL

S-000 ABBREVIATIONS, SYMBOLS, AND SHEET INDEX

S-100 GENERAL NOTES

S-101 GENERAL NOTES

S-200 FOUNDATION OVERALL PLAN

S-201A BUILDING FOUNDATION PLAN - AREA A

S-201B BUILDING FOUNDATION PLAN - AREA B

S-202 BUILDING MEZZANINE FLOOR PLAN

S-203 BUILDING ROOF OVERALL PLAN

S-210A EQUIPMENT FOUNDATION PLAN - AREA A

S-210B EQUIPMENT FOUNDATION PLAN - AREA B

S-301 TYPICAL FOUNDATION DETAILS

S-302 TYPICAL FOUNDATION DETAILS

S-303 TYPICAL FOUNDATION DETAILS

S-304 EQUIPMENT FOUNDATION DETAILS

S-305 TANK FARM FOUNDATION DETAILS

S-306 EQUIPMENT LOADING SCHEDULES

S-501 TYPICAL CMU DETAILS

MECHANICAL

M0.01 MECHANICAL COVER SHEET

M0.02 MECHANICAL SCHEDULES

M2.01 OVERALL MECHANICAL PLAN - FIRST FLOOR

M2.01A MECHANICAL PLAN - FIRST FLOOR - AREA A

M2.01B MECHANICAL PLAN - FIRST FLOOR - AREA B

M2.02 OVERALL MECHANICAL PLAN - MEZZANINE

M2.02A MECHANICAL PLAN - MEZZANINE - AREA A

M2.02B MECHANICAL PLAN - MEZZANINE - AREA B

M2.03 OVERALL MECHANICAL PLAN - ROOF

M3.01 OVERALL MECHANICAL CEILING PLAN - FIRST FLOOR

M6.01 MECHANICAL DETAILS

M6.02 MECHANICAL DETAILS

MEP2.00 CEILING ACCESS PLAN

ELECTRICAL

E0.01 ELECTRICAL COVER SHEET

E0.02 ELECTRICAL SCHEDULES

E1.01 ELECTRICAL SITE PLAN WEST

E1.02 ELECTRICAL SITE PLAN EAST

E2.00 OVERALL GROUNDING PLAN

E2.01 POWER PLAN - FIRST FLOOR

E2.01A POWER PLAN - FIRST FLOOR - AREA A

E2.01B POWER PLAN - FIRST FLOOR - AREA B

E2.02 POWER PLAN - MEZZANINE

E2.02A POWER PLAN - MEZZANINE - AREA A

E2.02B POWER PLAN - MEZZANINE - AREA B

E2.03 ELECTRICAL ROOF PLAN

E3.00A LIGHTING PLAN - UNDER PLATFORM & CANOPY - AREA A

E3.00B LIGHTING PLAN - UNDER PLATFORM & CANOPY - AREA B

E3.01A LIGHTING PLAN - FIRST FLOOR - AREA A

E3.01B LIGHTING PLAN - FIRST FLOOR - AREA B

E3.02A LIGHTING PLAN - MEZZANINE - AREA A

E3.02B LIGHTING PLAN - MEZZANINE - AREA B

E6.01 ELECTRICAL DETAILS

E6.02 ELECTRICAL DETAILS

E7.00 ELECTRICAL ONE-LINE DIAGRAM

E7.01 ELECTRICAL PANEL SCHEDULES

PLUMBING

P0.01 PLUMBING COVER SHEET

P0.02 PLUMBING SCHEDULES

P2.00 OVERALL PLUMBING UNDERFLOOR PLAN

P2.00A PLUMBING UNDERFLOOR PLAN - AREA A

P2.00B PLUMBING UNDERFLOOR PLAN - AREA B

P2.01 OVERALL PLUMBING FLOOR PLAN - FIRST FLOOR

P2.01A PLUMBING PLAN - FIRST FLOOR - AREA A

P2.01B PLUMBING PLAN - FIRST FLOOR - AREA B

P2.04 OVERALL PLUMBING PLAN - ROOF

P2.04A PLUMBING PLAN - ROOF - AREA A

P2.04B PLUMBING PLAN - ROOF - AREA B

P5.01 PLUMBING RISERS

P5.02 PLUMBING RISERS

P5.03 PLUMBING RISERS

P6.01 PLUMBING DETAILS

P6.02 PLUMBING DETAILS

VICINITY MAP

Scale: 3/8" = 1'-0"1

FIXTURE MOUNTING HEIGHTS

NO. DESCRIPTION DATE

Page 3: ARCHITECT: TK BUILDING ISSUED FOR BID & PERMIT JUNE 18, …c-air-s.com/plans/haldor_topsoe_mech_dwgs.pdf · gb-01 1 scale: view name 1/8" = 1'-0" 1/a101 1 a101 sim callout building/wall

10

10

9

9

8

8

7

7

6

6

5

5

4

4

3

3

2

2

1

1

D D

A A

B B

11

11

E E

A1

A-311

A3

A-311

E5

A-314

12

12

A.5 A.5

5.5 7.5

A.4 A.4

4.22.9

13

13

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G G G

G G G

G

G

G

G

G

G

G

GGGG

G G G G GG

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G G

G G

G G

G

G

G

G

G

G

GG G G G G G G G G G G G G G G G G

GG G G G G G G G

G G G G G G G GGG G G G G

GG G G G G

G G G G G

G G G G G

G G G G G

GG G G G G GG

G G G G

G

G

G

G G

G G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G G G

G G G

G G G

G

GGG

GGG

GGG

G

G

G

G

G

G

G G

GG

GG

C

C

C

C

C

C

C

C

C C C C C C C C C C C C C C C C C C C C C C C C C

C

C

C

2.1

1 m

6' -

11

"

8.3

m

27

' - 2

47/6

4"

1.8

3 m

6' -

0"

2.3

4 m

7' -

8 6

9/2

56

"

1.0

4 m

3' -

5"

2.3

4 m

7' -

8"

2.3

4 m

7' -

8"

2.3

4 m

7' -

8"

2.5

4 m

8' -

4"

5.6

8 m

18

' - 7

1/2

"

4.19 m

13' - 9"

6.77 m

22' - 2 1/2"

1.98 m

6' - 6"

2.64 m

8' - 8"

3.84 m

12' - 7"

2.64 m

8' - 8"

4.98 m

16' - 4"

2.64 m

8' - 8"

3.63 m

11' - 11"

2.49 m

8' - 2"

2.64 m

8' - 8"

3.84 m

12' - 7"

2.64 m

8' - 8"

4.6 m

15' - 1"

2.64 m

8' - 8"

1.83 m

6' - 0"

3.53 m

11' - 7"

2.64 m

8' - 8"

4.98 m

16' - 4"

2.64 m

8' - 8"

3.84 m

12' - 7"

2.64 m

8' - 8"

2.49 m

8' - 2"

3.57 m

11' - 8 1/2"

2.64 m

8' - 8"

3.31 m

10' - 10 1/2"

0.7

2 m

2' -

4 1

/2"

2.0

1 m

6' -

7"

1.8

3 m

6' -

0"

1.8

3 m

6' -

0"

1.8

3 m

6' -

0"

1.8

3 m

6' -

0"

1.59 m

5' - 2 1/2"

2.46 m

8' - 1"

1.88 m

6' - 2"

1.3

5 m

4' -

5"

1.3

2 m

4' -

4"

1.3

5 m

4' -

5"

0.3

3 m

1' -

1 1

/8"

1.3

1 m

4' -

3 1

/2"

1.42 m

4' - 8"

3.94 m

12' - 11"

3.4 m

11' - 2"

3.4 m

11' - 2"

3.4 m

11' - 2"

3.4 m

11' - 2"

3.4 m

11' - 2"

3.4 m

11' - 2"

0.7

6 m

2' -

6"

1.9

3 m

6' -

4"

1.8

8 m

6' -

2"

1.8

8 m

6' -

2"

1.8

8 m

6' -

2"

1.9

3 m

6' -

4"

1.8

5 m

6' -

1"

1.8

m

5' -

11

"

1.8

8 m

6' -

2"

1.0

4 m

3' -

5"

1.0

7 m

3' -

6"

1.0

4 m

3' -

5"

1.0

4 m

3' -

5"

3.58 m

11' - 9"

3.58 m

11' - 9"

3.58 m

11' - 9"

3.58 m

11' - 9"

3.58 m

11' - 9"

3.58 m

11' - 9"

3.58 m

11' - 9"

3.58 m

11' - 9"

3.58 m

11' - 9"

3.58 m

11' - 9"

3.58 m

11' - 9"

3.58 m

11' - 9"

3.58 m

11' - 9"

3.58 m

11' - 9"

3.58 m

11' - 9"

3.58 m

11' - 9"

3.58 m

11' - 9"

3.58 m

11' - 9"

3.51 m

11' - 6"

3.58 m

11' - 9"

3.58 m

11' - 9"

0.97 m

3' - 2"

A1

A-314

C C

B.7 B.7

C.4 C.4

10.6

10.6

NOTE: LOCATION OF LIGHT FIXTURES ON HOLD. LOCATION TO SUIT FINAL LOCATION OF EQUIPMENT AND PLATFORMS.

-A.1 -A.1

APC-Y

10' - 0"

APC-Y

10' - 0"

APC-Y

10' - 0"

GYP

10' - 6"

APC-Y

10' - 0"

APC-Y

10' - 0"APC-Y

10' - 0"

APC-Y

10' - 0"

ES

ES

ESES

ES

ES ES

2x4 LIGHT FIXTURE; RECESSED AT GRID; SURFACE MTD AT EXPOSED DECK

PENDANT FIXTURE

SUPPLY DIFFUSER

RETURN DIFFUSER

EXIT SIGN

S SPEAKER

A FIRE ALARM

HEAT DETECTOR

SMOKE DETECTOR

LINEAR SLOT DIFFUSER

SPRINKLER HEAD

EMERGENCY LIGHT

RECESSED LIGHT FIXTURE

CEILING LEGEND

SUSPENDED ACOUSTICAL PANEL CEILING (APC-#)

GYPSUM BOARD CEILING(GYP BD-#)

ROLLER SHADE

SUSPENDED OPEN GRID CEILING SYSTEM

DROP IN RESIN PANEL ON SUSPENDED OPEN GRID CEILING SYSTEM

SURFACE MOUNTEDLIGHT FIXTURE

STRIP FIXTURE

TRACK LIGHTINGCONTROL JOINTCJ

HORN/STROBE DEVICE

EXHAUST AIR DEVICE

OCCUPANCY SENSOR

CEILING ACCESS PANEL(AP-#) SEE PLAN FOR TYPE

DAYLIGHTING SENSOR

s SPEAKER/STROBE

STROBE

ES EXPOSED STRUCTURENOTE: FOR MEPFP DEVICES, REFER TO MEPFP DRAWINGS.

APC-X

8' - 0"

CEILING TYPE

CEILING HEIGHT

HIGH BAY FIXTURE H

A

D

V

WALL PAK

W

UNDER EQUIPMENT SURFACE MOUNTED LIGHT FIXTURE G

6

A

54321

B

C

D

E

F

SCALE

APPROVED BY

CHECKED BY

SHEET NO.

TITLE

DRAWN BY

DATE

PROJECT NO.

REVISIONS

SEAL

10260 Westheimer Rd. Suite 250 Houston, TX 77042713.429.4949

Infinity MEP Consultants

Matrix Structural

5177 Richmond Avenue Suite 670 Houston, TX 77056713.664.0130

600 Parsippany Rd Suite 301Parsippany, NJ 07054713.576.0148

Dewberry Engineers Inc.

ISSUE FOR BID & PERMIT

A B

KEY PLAN

6/1

8/2

021 4

:24

:22

PM

FIRST FLOORRCP - UNDER

PLATFORM ANDCANOPY

Author

Checker

Approver

06/18/2021

50132460

TK

BU

ILD

ING

HA

LD

OR

TO

PS

OE

100

10

BA

YP

OR

T B

LV

D,

PA

SA

DE

NA

, T

X,

775

07

Dewberry Architects, Inc.

5051 Westheimer RdSuite 320Houston, TX 77056713.621.8714

A-113AScale: 3/32" = 1'-0"A1

FIRST FLOOR REFLECTED CEILING PLAN - UNDER EQUIPMENT PLATFORM AND CANOPY LIGHTING

0' 10' 20'5'

SCALE: 3/32" = 1' - 0"

NO. DESCRIPTION DATE

Page 4: ARCHITECT: TK BUILDING ISSUED FOR BID & PERMIT JUNE 18, …c-air-s.com/plans/haldor_topsoe_mech_dwgs.pdf · gb-01 1 scale: view name 1/8" = 1'-0" 1/a101 1 a101 sim callout building/wall

10

10

9

9

8

8

7

7

6

6

5

5

4

4

3

3

2

2

1

1

D D

A A

B B

11

11

E E

A1

A-311

12

12

8.34 m

27' - 4 1/2"

SKYLIGHTS, TYP.

7.62 m

25' - 0"

7.62 m

25' - 0"

7.62 m

25' - 0"

4.04 m

13' - 3"

EQ EQ

EQ

EQ

1.22 m

4' - 0"

5.79 m

19' - 0"

5.94 m

19' - 6"

4.88 m

16' - 0"

5.94 m

19' - 6"

5.33 m

17' - 6"

5.18 m

17' - 0"

5.49 m

18' - 0"

5.33 m

17' - 6"

5.79 m

19' - 0"

5.18 m

17' - 0"

5.79 m

19' - 0"

5.94 m

19' - 6"

5.03 m

16' - 6"

4.06 m

13' - 4"

EQ

EQ

3.81 m

12' - 6"

7.62 m

25' - 0"

7.62 m

25' - 0"

7.62 m

25' - 0"

7.62 m

25' - 0"

7.62 m

25' - 0"

3.81 m

12' - 6"

0.9

1 m

3' -

0"

6.5

5 m

21

' - 6

"

3.81 m

12' - 6"

15.24 m

50' - 0"

7.62 m

25' - 0"

0.91 m

3' - 0"

9.14 m

30' - 0"

8.99 m

29' - 6"

3.5

1 m

11

' - 6

"

5.7

9 m

19

' - 0

"

10.0

6 m

33

' - 0

"

1.42 m

4' - 8"

0.6

9 m

2' -

3"

3.66 m

12' - 0"

3.96 m

13' - 0"

3.96 m

13' - 0"

3.66 m

12' - 0"

2.95 m

9' - 8"

EQ

EQ2.44 m

8' - 0"

7.62 m

25' - 0"

A.5 A.5

5.5

5.5

7.5

7.5

A.4 A.4

4.2

4.2

2.9

2.9

7.3

2 m

24

' - 0

"

4.0

8 m

13

' - 4

1/2

"

4.8

3 m

15

' - 1

0"

0.91 m

3' - 0"

9.14 m

30' - 0"

8.99 m

29' - 6"

4.52 m

14' - 10"

2.77 m

9' - 1"

2.16 m

7' - 1"

2.16 m

7' - 1"

2.77 m

9' - 1"

0.9

1 m

3' -

0"

1.0

2 m

3' -

4"

1.84 m

6' - 0 1/2"

3.78 m

12' - 5"

1.85 m

6' - 1"

1.88 m

6' - 2"

3.99 m

13' - 1"

1.96 m

6' - 5"

1.0

9 m

3' -

7"

1.7

2 m

5' -

7 2

5/3

2"

1.8

2 m

5' -

11

25/3

2"

1.8

2 m

5' -

11

25/3

2"

1.8

2 m

5' -

11

25/3

2"

1.1 m

3' - 7 3/8"

1.13 m

3' - 8 95/256"

H

H

H

H H H H H H H H H H H H H H H

HHHHHHHH

HH

H H H H H H

H H H

H

H

H

H

H

H

HHH

A

AA

A

A A A A

A A

AAA

AA

AA

A

A A

AA

A

A

A

A A A

A

V

V

V V

VV

V V V V

V V V

V

V

V

V

V

V V

V

V V

V

V

W

W

W

W

W

WWWW

W

W

W

W

W W

W

W W

W W

DDD

DDD

GYPSUM BOARD CEILING

METAL PANELS

LINEAR LED LIGHTS

13

13

D D

DD

W

3

A-531

A1

A-314

C C

B.7 B.7

C.4 C.4

10.6

10.6

-A.1 -A.1

38' - 6"

ESES

ES

ES

ES ES

ES

APC-Y

10' - 0"

APC-Y

10' - 0"

APC-Y

10' - 0"

APC-Y

10' - 0"

GYP

10' - 6"

APC-Y

10' - 0"

APC-Y

10' - 0"

APC-Y

10' - 0"

2x4 LIGHT FIXTURE; RECESSED AT GRID; SURFACE MTD AT EXPOSED DECK

PENDANT FIXTURE

SUPPLY DIFFUSER

RETURN DIFFUSER

EXIT SIGN

S SPEAKER

A FIRE ALARM

HEAT DETECTOR

SMOKE DETECTOR

LINEAR SLOT DIFFUSER

SPRINKLER HEAD

EMERGENCY LIGHT

RECESSED LIGHT FIXTURE

CEILING LEGEND

SUSPENDED ACOUSTICAL PANEL CEILING (APC-#)

GYPSUM BOARD CEILING(GYP BD-#)

ROLLER SHADE

SUSPENDED OPEN GRID CEILING SYSTEM

DROP IN RESIN PANEL ON SUSPENDED OPEN GRID CEILING SYSTEM

SURFACE MOUNTEDLIGHT FIXTURE

STRIP FIXTURE

TRACK LIGHTINGCONTROL JOINTCJ

HORN/STROBE DEVICE

EXHAUST AIR DEVICE

OCCUPANCY SENSOR

CEILING ACCESS PANEL(AP-#) SEE PLAN FOR TYPE

DAYLIGHTING SENSOR

s SPEAKER/STROBE

STROBE

ES EXPOSED STRUCTURENOTE: FOR MEPFP DEVICES, REFER TO MEPFP DRAWINGS.

APC-X

8' - 0"

CEILING TYPE

CEILING HEIGHT

HIGH BAY FIXTURE H

A

D

V

WALL PAK

W

UNDER EQUIPMENT SURFACE MOUNTED LIGHT FIXTURE G

3

3

2

2

1

1

D D

A A A

AAA

ELECTRICAL ROOM

38

2.44 m

8' - 0"

3.66 m

12' - 0"

3.66 m

12' - 0"

2.44 m

8' - 0"

3.0

5 m

10

' - 0

"

C C

C.4 C.4

ES

A A

B B

11

11

12

12

1.5

2 m

5' -

0"

2.89 m

9' - 5 31/32"

3.66 m

12' - 0"

3.66 m

12' - 0"

3.11 m

10' - 2 15/32"

A A A

AAA

3.1

8 m

10

' - 5

"

10.6

10.6

ES

6

A

54321

B

C

D

E

F

SCALE

APPROVED BY

CHECKED BY

SHEET NO.

TITLE

DRAWN BY

DATE

PROJECT NO.

REVISIONS

SEAL

10260 Westheimer Rd. Suite 250 Houston, TX 77042713.429.4949

Infinity MEP Consultants

Matrix Structural

5177 Richmond Avenue Suite 670 Houston, TX 77056713.664.0130

600 Parsippany Rd Suite 301Parsippany, NJ 07054713.576.0148

Dewberry Engineers Inc.

ISSUE FOR BID & PERMIT

A B

KEY PLAN

6/1

8/2

021 4

:24

:23

PM

FIRST FLOOROVERALL

REFLECTEDCELIING PLAN

Author

Checker

Approver

06/18/2021

50132460

TK

BU

ILD

ING

HA

LD

OR

TO

PS

OE

100

10

BA

YP

OR

T B

LV

D,

PA

SA

DE

NA

, T

X,

775

07

Dewberry Architects, Inc.

5051 Westheimer RdSuite 320Houston, TX 77056713.621.8714

A-113BScale: 3/32" = 1'-0"A1

FIRST FLOOR REFLECTED CEILING PLAN

0' 10' 20'5'

SCALE: 3/32" = 1' - 0"

Scale: 3/32" = 1'-0"E1

Mezzanine Reflected Ceiling Plan - Electrical Room 38Scale: 3/32" = 1'-0"

E3Mezzanine Reflected Ceiling Plan - Electrical Room 39

NO. DESCRIPTION DATE

Page 5: ARCHITECT: TK BUILDING ISSUED FOR BID & PERMIT JUNE 18, …c-air-s.com/plans/haldor_topsoe_mech_dwgs.pdf · gb-01 1 scale: view name 1/8" = 1'-0" 1/a101 1 a101 sim callout building/wall

20x14

10∅

FUSIBLE LINK FIRE DAMPER

MOTORIZED DAMPER

RECTANGULAR SUPPLY DUCT UP

RECTANGULAR SUPPLY DUCT DOWN

RECTANGULAR RETURN DUCT UP

RECTANGULAR RETURN DUCT DOWN

ROUND SUPPLY DUCT UP

ROUND SUPPLY DUCT DOWN

DUCT SIZE (CLEAR INSIDE DIMENSION)FIRST FIGURE INDICATES PLAN SIZE

ROUND DUCT DIAMETER SIZE(CLEAR INSIDE DIMENSION)

RECTANGULAR OR SQUARE TO ROUNDOR OVAL TRANSITION

RECTANGULAR EXHAUST DUCT UP

RECTANGULAR EXHAUST DUCT DOWN

ROUND RETURN DUCT UP

ROUND RETURN DUCT DOWN

ROUND EXHAUST DUCT UP

ROUND EXHAUST DUCT DOWN

POINT OF CONNECTION (NEW TO EXISTING)

M

FLEXIBLE CONNECTION

VOLUME DAMPER (MANUAL)

MECHANICAL LEGEND

RETURN GRILLE

LINEAR DIFFUSER WITH PLENUM

RETURN LINEAR DIFFUSER

EXHAUST GRILLE

SUPPLY DIFFUSER

CT - 1-1EQUIPMENT DESIGNATION

AIR OUTLET/INLETDEVICE DESIGNATION

A

PIPE CAP

DIRECTION OF FLOW

THERMOSTAT

HUMIDISTAT

PRESSURE SENSOR

UNION

STRAINER WITH BLOW OFF VALVE

PIPE DROPPING DOWN

PIPE RISING UP

DIRECTION OF FLOW

BALANCING VALVE

MANUAL AIR VENT

CONCENTRIC REDUCER

ECCENTRIC REDUCER

PRESSURE REDUCING VALVE (PRV)

SOLENOID VALVE

TWO WAY CONTROL VALVE

THREE WAY CONTROL VALVE

STRAINER

BALL VALVE

GATE VALVE, ANGLE

SWING CHECK VALVE

BUTTERFLY VALVE

EXPANSION LOOP (WxH)

ELECTRICALLY TRACED PIPING

GAS PRESSURE REGULATOR

STRAINER

ANCHOR

THERMOMETER

EXPANSION JOINT

GUIDE

S

W

H

MECHANICAL LEGEND

T

H

P

SIZE

(CFM)

MOTORIZED FIRE SMOKE DAMPER

SMOKE DAMPER

VANED ELBOW

ACCESS DOOR (AD)

BRANCH DUCT TAKE-OFF

INTERNALLY LINED DUCT

RADIUS ELBOW

BACK DRAFT DAMPER

FLEXIBLE DUCTWORK

S

M

BDD

EXISTING TO REMAIN

DEMOLISHED OR RELOCATED EQUIPMENT OR MATERIALS

NEW CONSTRUCTION

6

A

54321

B

C

D

E

F

SCALE

APPROVED BY

CHECKED BY

SHEET NO.

TITLE

DRAWN BY

DATE

PROJECT NO.

REVISIONS

SEAL

TBPE Registeration Number 1886510260 Westheimer Rd. Suite 250 Houston, TX 77042713.429.4949www.infinitymep.com

Infinity MEP Consultants

Matrix Structural

5177 Richmond Avenue Suite 670 Houston, TX 77056713.664.0130

600 Parsippany Rd Suite 301Parsippany, NJ 07054713.576.0148

Dewberry Engineers Inc.

ISSUE FOR BID AND PERMIT

6/1

5/2

021 4

:00

:15

PM

C:\U

se

r s\b

rupp

\Docum

en

ts\H

2032

5-H

ald

or

Topsoe P

rodu

ction

Pla

nt -

ME

P_

r20

_b

rup

pY

LU

YF

.rvt

MECHANICALCOVER SHEET

BR

NB

06/18/2021

50132460

TK

BU

ILD

ING

HA

LD

OR

TO

PS

OE

10

01

0 B

AY

PO

RT

BL

VD

.P

AS

AD

EN

A,

TX

77

50

7

M0.01

MECHANICAL SHEET LISTSHEET

NUMBER SHEET NAMEM0.01 MECHANICAL COVER SHEET

M0.02 MECHANICAL SCHEDULES

M2.01 OVERALL MECHANICAL PLAN - FIRST FLOOR

M2.01A MECHANICAL PLAN - FIRST FLOOR - AREA A

M2.01B MECHANICAL PLAN - FIRST FLOOR - AREA B

M2.02 OVERALL MECHANICAL PLAN - MEZZANINE

M2.02A MECHANICAL PLAN - MEZZANINE - AREA A

M2.02B MECHANICAL PLAN - MEZZANINE - AREA B

M2.03 OVERALL MECHANICAL PLAN - ROOF

M3.01 OVERALL MECHANICAL CEILING PLAN - FIRST FLOOR

M6.01 MECHANICAL DETAILS

M6.02 MECHANICAL DETAILS

MEP2.00 CEILING ACCESS PLAN

MECHANICAL GENERAL NOTES1 ALL WORK PERFORMED FOR THIS PROJECT SHALL BE IN ACCORDANCE WITH ALL

APPLICABLE LOCAL, STATE AND FEDERAL BUILDING CODES, MECHANICAL CODES,ENERGY CODES AND THEIR AMENDMENTS. THE MORE STRINGENT CODE SHALLAPPLY.

2 CONTRACTOR SHALL VISIT THE PROJECT SITE TO BECOME FAMILIAR WITH THEEXISTING CONDITIONS. FAILURE TO DO SO SHALL NOT RELIEVE CONTRACTOR OFRESPONSIBILITY FROM PERFORMING WORK PROPERLY.

3 CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL WORK UNDER THEIRCONTACT PRIOR TO FABRICATION, ROUGH-IN AND FINAL CONNECTION.

4 HVAC AND PIPING WORK IS SHOWN DIAGRAMMATIC IN NATURE. DRAWINGSSHOULD NOT BE SCALED. PROVIDE ALL OFFSETS AND FITTINGS REQUIRED TO FITWITHIN AVAILABLE SPACE. COORDINATE WORK WITH STRUCTURAL,ARCHITECTURAL, PLUMBING AND ELECTRICAL PRIOR TO INSTALLATION.

5 LOCATE ALL EQUIPMENT TO ALLOW FOR SERVICE ACCESS. COORDINATELOCATION WITH OTHER TRADES. DO NOT ALLOW ACCESS TO BE ENCROACHEDUPON BY CONDUITS, PIPE AND OTHER MATERIALS.

6 PROVIDE ACCESS DOORS FOR ALL EQUIPMENT, VALVES, DAMPERS, ETC. ABOVEALL NON-LAY-IN CEILINGS FOR MAINTENANCE AND SERVICE.

7 ALL RECTANGULAR AND ROUND DUCTWORK IS TO BE CONSTRUCTED OFGALVANIZED SHEET METAL, UNLESS NOTED OTHERWISE. ALL DUCTWORK SHALLBE CONSTRUCTED PER THE LATEST SMACNA DUCT STANDARDS.

8 ALL DUCTWORK SIZES INDICATED ARE CLEAR INSIDE DIMENSIONS. CONTRACTORTO ALLOW FOR DUCT LINING AS REQUIRED. IF RESIZING IS REQUIRED IT SHALL BEDONE PER THE EQUAL FRICTION METHOD.

9 DUCT RUN-OUTS TO SUPPLY AIR DIFFUSERS SHALL BE THE SAME SIZE AS THEDIFFUSER NECK.

10 FOR EACH HEATING OR COOLING UNIT PROVIDE A TEMPERATURE SENSINGDEVICE. LOCATE DEVICE WHERE SHOWN ON DRAWINGS AND COORDINATELOCATION WITH ARCHITECT, OTHER WALL DEVICES AND PER ADA GUIDELINES.

11 INSTALL ALL MECHANICAL EQUIPMENT PER MANUFACTURER'S INSTRUCTIONS ANDRECOMMENDATIONS. IF CONTRACTOR SUBSTITUTES EQUIPMENT AND AFTERAPPROVAL BY THE ENGINEER, THE CONTRACTOR SHALL MAKE ALL NECESSARYMODIFICATIONS TO THE SYSTEM AS REQUIRED TO PROVIDE INSTALLATION ATCONTRACTORS COST.

12 CONTRACTOR TO VERIFY ALL ELECTRICAL CHARACTERISTICS OF MECHANICALEQUIPMENT WITH ELECTRICAL DRAWINGS BEFORE EQUIPMENT RELEASE.

13 COORDINATE ALL SLEEVE, CHASE AND SLAB BLOCK-OUTS WITH EXISTINGSTRUCTURE. COORDINATE ACTUAL EQUIPMENT DIMENSION WITH OTHERTRADES.

14 COORDINATE CEILING DIFFUSER FRAME TYPES AND COLORS WITHARCHITECTURAL CEILINGS.

15 FOR PIPES PASSING THROUGH FIRE RATED WALLS AND FLOORS PROVIDE WITH ULLISTED ASSEMBLIES AND MATERIALS TO OBTAIN REQUIRED FIRE RATING.

16 PROVIDE 1-1/2” ACOUSTICAL LINING ON ALL DUCTWORK WITHIN 10’-0” OF RTU/AHU.ALL OTHER DUCTWORK IS TO BE INSULATED WITH 1-1/2” FIBERGLASSWRAP/INSULATION.

17 PROVIDE ALL TRANSITION AS NECESSARY TO MAKE CONNECTION TO HVACEQUIPMENT.

18 ALL PIPING, DUCTWORK AND EQUIPMENT SHALL BE SUPPORTED PER THE LATESTEDITION OF SMACNA.

19 PROVIDE DUCT ACCESS DOORS ON ALL MOTORIZED DAMPERS, FIRE DAMPERS,SMOKE DAMPERS, BACKDRAFT DAMPERS AND FIRE/SMOKE DAMPERS.

20 CONTRACTOR SHALL COORDINATE WITH BUILDING MANAGEMENT AND BUILDINGENGINEER FOR ALL BASE BUILDING STANDARDS, DEVICE, CONTROLS AND ALLASSOCIATED EQUIPMENT AS REQUIRED FOR A COMPLETE INSTALLATION.

21 FLEXIBLE DUCTWORK FOR CONNECTION TO AIR DEVICES SHALL BE LIMITED TO5’-0” IN LENGTH. FOR LONGER CONNECTIONS USE INSULATED RIGID SPIRALROUND DUCTWORK. SPLIT SEAM ROUND DUCTWORK IS NOT ALLOWED.

22 PROVIDE MANUAL VOLUME DAMPERS AT DUCT TAKEOFFS FROM MAINS.DAMPERS SHALL BE LOCATED IN ACCESSIBLE LOCATIONS. AVOID THEINSTALLATION OF DAMPERS AT DIFFUSERS DUE TO NOISE ISSUES.

23 A NEBB OR AABC CERTIFIED BALANCE COMPANY SHALL BE USED TO BALANCE ALLDEVICES TO CFM AND GPM AS REQUIRED ON THE DRAWINGS. PROVIDEBALANCING REPORTS OF ALL EQUIPMENT AND DEVICES TO OWNER.

24 PROVIDE SMACNA DUCT TRANSITIONS TO ALL TERMINAL UNIT INLETS ANDOUTLETS FOR CONNECTION TO DUCTWORK.

25 ALL EXHAUST FAN OUTLETS SHALL BE A MINIMUM OF 10’ FROM ALL BUILDING AIRINTAKES AND OPENINGS.

26 ALL EXTERIOR BUILDING PENETRATION SHALL BE SEALED WATER TIGHT. ALLINTERIOR WALL AND FLOOR PENETRATIONS FOR DUCTWORK AND PIPING SHALLBE MEET THE FIRE RATING OF THE ARCHITECTURAL PLANS AND WILL BEINSTALLED TO MEET ALL UL ASSEMBLY REQUIREMENTS.

27 PROVIDE MANUAL BALANCE DAMPERS AT EACH BRANCH DUCT TO ALL SUPPLYDIFFUSERS, EXHAUST GRILLS AND DUCTED RETURN GRILLES.

28 PROVIDE 4” CONCRETE HOUSEKEEPING PAD FOR ALL FLOOR MOUNTED ANDGRADE MOUNTED EQUIPMENT, UNLESS NOTED OTHERWISE.

29 REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOUVER LOCATIONS ANDCOORDINATE LOUVER PLACEMENT WITH ARCHITECT.

30 PROVIDE MOTORIZED DAMPERS ON ALL EXTERIOR BUILDING PENETRATIONS.INTERLOCK WITH RESPECTIVE FANS. DAMPER TO FAIL CLOSED, UNLESS NOTEDOTHERWISE.

31 PROVIDE SMOKE DETECTOR/S ON ALL AIR HANDLING EQUIPMENT 2,000 CFM ORGREATER TO MEET ALL NFPA REQUIREMENTS. FOR AIR HANDLING EQUIPMENT15,000 CFM OR GREATER PROVIDE MOTORIZED ISOLATION DAMPERS ON ALLINLETS AND OUTLETS OF THE UNIT TO MEET ALL NFPA REQUIREMENTS. DAMPERSTO BE INTERLOCKED WITH UNIT.

MECHANICAL ABBREVIATIONS(E) EXISTING TO REMAIN

AC AIR CONDITIONING UNIT

AD ACCESS DOOR

AFF ABOVE FINISHED FLOOR

AHU AIR HANDLING UNIT

AL ACOUSTICAL LINING

AP ACCESS PANEL

BDD BACK DRAFT DAMPER

BFC BELOW FINISHED CEILING

BHP BRAKE HORSEPOWER

BMS BUILDING MANAGEMENT SYSTEM

BTU BRITISH THERMAL UNIT

CA COMPRESSED AIR

CD CEILING DIFFUSER

CFM CUBIC FEET PER MINUTE

CH CHILLER

CHP CHILLED WATER PUMP

CHR CHILLED WATER RETURN

CHS CHILLED WATER SUPPLY

CO CLEAN OUT

COND CONDENSATE DRAIN

CP CONDENSATE PUMP

CRAC COMPUTER ROOM AIR CONDITIONING UNIT

CT COOLING TOWER

CU CONDENSING UNIT

CUH CABINET UNIT HEATER

CWP CONDENSER WATER PUMP

CWR CONDENSER WATER RETURN

CWS CONDENSER WATER SUPPLY

DB DRY BULB

DWP DOMESTIC WATER PUMP

DX DIRECT EXPANSION

EAT ENTERING AIR TEMPERATURE

EF EXHAUST FAN

ERU ENERGY RECOVERY UNIT

ESP EXTERNAL STATIC PRESSURE

ET EXPANSION TANK

EUH ELECTRIC UNIT HEATER

EWC ELECTRIC WATER COOLER

EWT ENTERING WATER TEMPERATURE

FA FREE AREA

FCU FAN COIL UNIT

FD FIRE DAMPER

FLA FULL LOAD AMPS

FLR FLOOR

FOP FUEL OIL PUMP

FP FIRE PUMP

FPM FEET PER MINUTE

FPTU FAN POWERED TERMINAL UNIT

FSD COMBINATION FIRE AND SMOKE DAMPER

GPM GALLONS PER MINUTE

HP HORSEPOWER

HP HEAT PUMP

HW HOT WATER

HWP HOT WATER PUMP

HWR HEATING HOT WATER RETURN

HWS HEATING HOT WATER SUPPLY

HX HEAT EXCHANGER

HZ HERTZ

ID INSIDE DIAMETER

KW KILOWATT

LAT LEAVING AIR TEMPERATURE

LB POUND

LF LINEAR FEET

LWT LEAVING WATER TEMPERATURE

MA MAKE-UP AIR (OUTSIDE AIR)

MBH THOUSAND BTU PER HOUR

MOCP MAXIMUM OVERCURRENT PROTECTION

MOD MOTOR OPERATED DAMPER

MTD MOUNTED

MUA MAKE-UP AIR UNIT

NC NORMALLY CLOSED

NIC NOT IN CONTRACT

NK NECK

NO NORMALLY OPEN

NTS NOT TO SCALE

OA OUTSIDE AIR

OAHU OUTSIDE AIR HANDLING UNIT

OAT OUTSIDE AIR TEMPERATURE

OBD OPPOSED BLADE DAMPER

OD OUTSIDE DIAMETER

PBD PARALLEL BLADE DAMPER

PRV PRESSURE REDUCING VALVE

PSI POUNDS PER SQUARE INCH (GAUGE)

PTAC PACKAGED TERMINAL AIR CONDITIONER

RA RETURN AIR

RAG RETURN AIR GRILL

RCP REFLECTED CEILING PLAN

RF RETURN FAN

RH RELATIVE HUMIDITY

RHC REHEAT COIL

RPM REVOLUTIONS PER MINUTE

RTU ROOFTOP UNIT

SA SUPPLY AIR

SD SMOKE DAMPER

SEF SMOKE EXHAUST FAN

SF SUPPLY FAN

SP STATIC PRESSURE

TYP TYPICAL

UH UNIT HEATER

UON UNLESS OTHERWISE NOTED

VAV VARIABLE AIR VOLUME UNIT

VD VOLUME DAMPER

VFD VARIABLE FREQUENCY DRIVE

VTR VENT THROUGH ROOF

WB WET BULB

°F DEGREES FAHRENHEIT

NO. DESCRIPTION DATE

06/15/2021

Page 6: ARCHITECT: TK BUILDING ISSUED FOR BID & PERMIT JUNE 18, …c-air-s.com/plans/haldor_topsoe_mech_dwgs.pdf · gb-01 1 scale: view name 1/8" = 1'-0" 1/a101 1 a101 sim callout building/wall

NOTES:

1. REFER TO SPECIFICATIONS FOR ADDITONAL INSULATION REQUIREMENTS AND JACKET DETAILS.2. AIR CONDITIONING AND REFRIGERATION PIPE AND TUBING LINES SHALL BE INSULATED WITH ACR TYPE INSULATION HAVING A THERMAL RESISTIVITY OF NOT LESS THAN R-4.

INDOORROUND/ FLAT-OVAL/

RECTANGULAR DUCT

MINERAL FIBER BOARD R-8 2 3 X X X ALUMINUM SMOOTH 55-60 MILS THICK 1

DOUBLE WALL, INSULATED R-8 NOTE 2 NOTE 2

ABOVE GROUND OUTDOOR

ROUND/ FLAT-OVAL/ RECTANGULAR DUCT

MINERAL FIBER BLANKET R-8 2 1-1/2

X X X FSK

DUCT INSULATION SCHEDULECONCEALED EXPOSED IN NON-SERVICE SPACES EXPOSED IN SERVICE/ MECHANICAL ROOMS

NOTESSUPPLY RETURN EXHAUST

OUTSIDE AIR

JACKET SUPPLY RETURN EXHAUSTOUTSIDE

AIRJACKET SUPPLY RETURN EXHAUST

OUTSIDE AIR

JACKETDUCT INSULATION TYPE

MIN./ INSTALLED INSULATION VALUE

MIN. THICKNESS MIN. NOMINAL DENSITY

X X X

MINERAL FIBER BOARD

DOUBLE WALL, INSULATED

MINERAL FIBER BLANKET

R-6 1-1/2 2

R-6 NOTE 2 NOTE 2

R-6 2 3/4

X X NONE

X X FSK 1

2

X X FSKX X

X

ALUMINUM SMOOTH 55-60 MILS THICK

6

A

54321

B

C

D

E

F

SCALE

APPROVED BY

CHECKED BY

SHEET NO.

TITLE

DRAWN BY

DATE

PROJECT NO.

REVISIONS

SEAL

TBPE Registeration Number 1886510260 Westheimer Rd. Suite 250 Houston, TX 77042713.429.4949www.infinitymep.com

Infinity MEP Consultants

Matrix Structural

5177 Richmond Avenue Suite 670 Houston, TX 77056713.664.0130

600 Parsippany Rd Suite 301Parsippany, NJ 07054713.576.0148

Dewberry Engineers Inc.

ISSUE FOR BID AND PERMIT

6/1

5/2

021 4

:00

:16

PM

C:\U

se

r s\b

rupp

\Docum

en

ts\H

2032

5-H

ald

or

Topsoe P

rodu

ction

Pla

nt -

ME

P_

r20

_b

rup

pY

LU

YF

.rvt

MECHANICALSCHEDULES

BR

NB

06/18/2021

50132460

TK

BU

ILD

ING

HA

LD

OR

TO

PS

OE

10

01

0 B

AY

PO

RT

BL

VD

.P

AS

AD

EN

A,

TX

77

50

7

M0.02

NOTES:

1. COORDINATE BORDER TYPE AND COLOR WITH ARCHITECT PRIOR TO PURCHASE.2. MATCH BUILDING STANDARD DIFFUSER/GRILLE. COORDINATE EXACT SPECIFICATION WITH BUILDING ENGINEER.

DIFFUSER NECK SIZES

SUPPLY CFM(MIN-MAX)

RETURNCFM

(MIN-MAX)RECTANGULAR NECK

SIZE (IN.) ROUND NECK SIZE (ø)0 - 100 0-90 6x6 6"

101 - 200 91-200 8x8 8"

201 - 400 201-300 10x10 10"

401 - 600 301-450 12x12 12"

601 - 900 451-700 14x14 14"

-- 701-2000 22 x 22 --

AIR DEVICE SCHEDULEDESIGNATION MANUFACTURER MODEL SERVICE

NECKDIMENSIONS

DESCRIPTION NOTES

A TITUS OMNI SUPPLY PER PLANS PLAQUE DIFFUSER 1,2,3

B TITUS OMNI EXHAUST PER PLANS PLAQUE AIR GRILLE 1,2,3

C TITUS OMNI RETURN PER PLANS PLAQUE AIR GRILLE 1,2,3

D TITUS 300 SUPPLY PER PLANS 3/4" BLADE SPACING, 0° DEFLECTION 1,2,3

FAN SCHEDULEEQUIPMENT

SERVICE LOCATION

UNIT TYPE

CFMEXT. S.P.(IN W.G.)

MOTOR

EMERGENCYPOWER

VARIABLESPEED

OPERATIONALWEIGHT (LBS.)

NOTESTYPE NUMBER MANUFACTURER MODEL RPM

BH

P

HP

VO

LT

AG

E

PH

AS

E

EF P-1 PRODUCTION ROOF GREENHECK RBU-2L48 31735 0.2 553 4.9 5 460 3 NO NO 555 1,2,3

EF P-2 PRODUCTION ROOF GREENHECK RBU-2L48 31735 0.2 553 4.9 5 460 3 NO NO 555 1,2,3

EF P-3 PRODUCTION ROOF GREENHECK RBU-2L48 31735 0.2 553 4.9 5 460 3 NO NO 555 1,2,3

EF O-1 OFFICE ROOF GREENHECK G-070-VG 250 0.4 1720 0.03 1/15 115 1 NO NO 25 1,2,3

EF AC-1AIR

COMPRESSORROOF GREENHECK G-090-G 500 0.2 1300 0.04 1/25 115 1 NO NO 30 1,2,3

NOTES:

1. PROVIDE WITH FACTORY MOUNTED ELECTRICAL DISCONNECT.2. FAN SHALL BE CONTROLLED BY BUILDING TIME CLOCK.3. PROVIDE WITH FACTORY ROOF CURB.

DX SPLIT SYSTEM SCHEDULEEQUIPMENT MANUFACTURER MODEL NUMBER INDOOR UNIT OUTDOOR UNIT

NOTES TYPE NUMBER INDOOR UNIT OUTDOOR UNIT

COOLING COILHEATPUMP

OPERATINGWEIGHT(LBS.)

EQUIPMENT

AM

BIE

NT

TE

MP

ER

AT

UR

E

ELECTRICALINFORMATION

OPERATINGWEIGHT(LBS.)

CF

M

OA

CF

M

FA

CE

VE

LO

CIT

Y (

FP

M)

EAT LAT CAPACITY

EX

T. S

TA

TIC

PR

ES

SU

RE

(IW

G)

RE

FR

IGE

RA

NT

CA

PA

CIT

Y (

MB

H)

TYPE NUMBER

VO

LT

AG

E

PH

AS

E

MC

A

MO

P

DB

(°F

)

WB

(°F

)

DB

(°F

)

WB

(°F

)

SE

NS

IBL

E M

BH

TO

TA

L M

BH

FCU 1 GUARDIAN - ME20DN21 / CM64DXA1 GUARDIAN - RHP14L60B23S 1720 185 500 79.7 65.3 55 54 43.3 54.0 0.62 R-410A 47.2 160 CU 1 105 230 1 31.7 50 260 1,2,3,4,5,6,7

FCU 2 TEMPMASTER - NST07C00C2BAA2 TEMPMASTER - YHT07C00A2QLA5 3000 - 500 75 63 55 54 66.4 83.3 0.5 R-410A - 525 CU 2 105 230 1 45.5 60 390 1,2,3,4,5,6,7

FCU 3 GUARDIAN - ME20DN21 / CM64DXA1 GUARDIAN - RHP14L60B23S 1740 - 500 75 63 55 54 39.0 47.7 0.5 R-410A - 160 CU 3 105 230 1 31.7 50 260 1,2,3,4,5,6,7

NOTES:

1. PROVIDE WITH ELECTRICAL DISCONNECT SWITCH AND SINGLE POINT POWER CONNECTION.2. PROVIDE WITH EC MOTORS.3. UNIT TO BE SELECTED AT MEDIUM SPEED.4. PROVIDE WITH LOW AMBIENT KIT.5. PROVIDE WITH 2" DISPOSABLE FILTER.6. IF REQUIRED FOR FINAL CONDENSATE ROUTING: PROVIDE WITH CONDENSATE PUMP. 115V/ 1ϕ MOTOR. INTERLOCK CONDENSATE PUMP WITH INTEGRAL FLOAT SWITCH.7. PROVIDE SMOKE DETECTOR IN RETURN AIR DUCT TO SHUT UNIT OFF UPON THE DETECTION OF SMOKE.

LOUVER SCHEDULEEQUIPMENT

SERVICE LOCATION

UNIT DIMENSIONS

MAX FACEVELOCITY

(FPM)

MINIMUMFREE AREA

(%)

MA

X. P

RE

SS

UR

E D

RO

P (

IN W

.G.)

NOTESTYPE NUMBER MANUFACTURER MODEL

LE

NG

TH

(IN

)

HE

IGH

T (

IN)

WID

TH

(IN

)

L 1 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 2 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 3 VENTILATION EXT. WALL GREENHECK EAC-601 12 88 71 500 50 0.1 1,2

L 4 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 5 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 6 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 7 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 8 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 9 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 10 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 11 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 12 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 13 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 14 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 15 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 16 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 17 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 18 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 19 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 20 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 21 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 22 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 23 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 24 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 25 VENTILATION EXT. WALL GREENHECK EAC-601 6 88 71 500 50 0.1 1,2

L 26 VENTILATION EXT. WALL GREENHECK EAC-601 6 24 24 500 50 0.1 1,2

NOTES:

1. CONFIRM FINAL LOUVER SIZE, COLOR, AND DETAILING WITH ARCHITECT PRIOR TO PURCHASE. 2. PROVIDE WITH COMBINATION LOUVER WITH DAMPER. DAMPER TO BE INTERLOCKED WITH EXHAUST FAN TO SEAL THE BUILDING WHEN NOT ENERGIZED.

NO. DESCRIPTION DATE

06/15/2021

Page 7: ARCHITECT: TK BUILDING ISSUED FOR BID & PERMIT JUNE 18, …c-air-s.com/plans/haldor_topsoe_mech_dwgs.pdf · gb-01 1 scale: view name 1/8" = 1'-0" 1/a101 1 a101 sim callout building/wall

RE

F.

WH

T

M

10987654321

D

A

C

11

E

12

/1 M2.01A /1 M2.01B

A.5

5.5 7.5

A.4

4.22.9 13

B.7

C.4

10.6

6

A

54321

B

C

D

E

F

SCALE

APPROVED BY

CHECKED BY

SHEET NO.

TITLE

DRAWN BY

DATE

PROJECT NO.

REVISIONS

SEAL

TBPE Registeration Number 1886510260 Westheimer Rd. Suite 250 Houston, TX 77042713.429.4949www.infinitymep.com

Infinity MEP Consultants

Matrix Structural

5177 Richmond Avenue Suite 670 Houston, TX 77056713.664.0130

600 Parsippany Rd Suite 301Parsippany, NJ 07054713.576.0148

Dewberry Engineers Inc.

ISSUE FOR BID AND PERMIT

6/1

5/2

021 4

:00

:17

PM

C:\U

se

r s\b

rupp

\Docum

en

ts\H

2032

5-H

ald

or

Topsoe P

rodu

ction

Pla

nt -

ME

P_

r20

_b

rup

pY

LU

YF

.rvt

OVERALLMECHANICAL PLAN -

FIRST FLOOR

BR

NB

Approver

06/18/2021

50132460

TK

BU

ILD

ING

HA

LD

OR

TO

PS

OE

10

01

0 B

AY

PO

RT

BL

VD

.P

AS

AD

EN

A,

TX

77

50

7

M2.013/32" = 1'-0"1

OVERALL MECHANICAL PLAN - FIRST FLOOR

NO. DESCRIPTION DATE

GENERAL NOTESA COORDINATE FINAL LAYOUTS AND REQUIREMENTS WITH PROCESS ENGINEER PRIOR TO BID.

06/15/2021

Page 8: ARCHITECT: TK BUILDING ISSUED FOR BID & PERMIT JUNE 18, …c-air-s.com/plans/haldor_topsoe_mech_dwgs.pdf · gb-01 1 scale: view name 1/8" = 1'-0" 1/a101 1 a101 sim callout building/wall

87654321

D

A

C

E

/1 M2.01B

CU-2

2

L-26

RL/RS

EF-AC-1

A.5

5.5 7.5

A.4

4.22.9

B.7

C.4

(ON ROOF)

1

3

6

A

54321

B

C

D

E

F

SCALE

APPROVED BY

CHECKED BY

SHEET NO.

TITLE

DRAWN BY

DATE

PROJECT NO.

REVISIONS

SEAL

TBPE Registeration Number 1886510260 Westheimer Rd. Suite 250 Houston, TX 77042713.429.4949www.infinitymep.com

Infinity MEP Consultants

Matrix Structural

5177 Richmond Avenue Suite 670 Houston, TX 77056713.664.0130

600 Parsippany Rd Suite 301Parsippany, NJ 07054713.576.0148

Dewberry Engineers Inc.

ISSUE FOR BID AND PERMIT

6/1

5/2

021 4

:00

:18

PM

C:\U

se

r s\b

rupp

\Docum

en

ts\H

2032

5-H

ald

or

Topsoe P

rodu

ction

Pla

nt -

ME

P_

r20

_b

rup

pY

LU

YF

.rvt

MECHANICAL PLAN -FIRST FLOOR - AREA

A

BR

NB

Approver

06/18/2021

50132460

TK

BU

ILD

ING

HA

LD

OR

TO

PS

OE

10

01

0 B

AY

PO

RT

BL

VD

.P

AS

AD

EN

A,

TX

77

50

7

M2.01A

KEYNOTESKEYNOTE DESCRIPTION

1 EXTERIOR LOUVER. COORDINATE DETAILING WITH ARCHITECT. RE: DETAIL AND SCHEDULE.

2 ROOF MOUNTED EXHAUST FAN.

3 CONDENSING UNIT TO BE LOCATED ON CONCRETE PAD. PROVIDE MANUFACTURER'S RECOMMENDATIONS FOR CLEARANCESAROUND CONDENSING UNIT. ROUTE REFRIGERANT PIPING TO ASSOCIATED FAN COIL UNIT. MANUFACTURER TO SIZEREFRIGRANT PIPING BASED ON FINAL EQUIPMENT PLACEMENT.

1/8" = 1'-0"1

MECHANICAL PLAN - FIRST FLOOR - AREA A

NO. DESCRIPTION DATE

GENERAL NOTESA COORDINATE FINAL LAYOUTS AND REQUIREMENTS WITH PROCESS ENGINEER PRIOR TO BID.

06/15/2021

Page 9: ARCHITECT: TK BUILDING ISSUED FOR BID & PERMIT JUNE 18, …c-air-s.com/plans/haldor_topsoe_mech_dwgs.pdf · gb-01 1 scale: view name 1/8" = 1'-0" 1/a101 1 a101 sim callout building/wall

RE

F.

WH

T

M

109

D

A

C

11

E

12

/1 M2.01A

145A

160A

(TYP. 2)

160A

160A

155A

90A

90A

50A

110A

110A

75A6ø

95A

80A

80A

100B

100B

55B

FCU-1

14x128x12

18x16

8x12

CU-1

12x12

8ø 10ø

12ø 12x12

12x14

12ø

100C

10ø

165C

115C

65C

85C

10ø

290C

12ø

425CRL/RS

3/4" COND. DRAIN

1

2

CU-32

EF-O-1

RL/RS

13

B.7

C.4

10.6

(ON ROOF)

8x8

38x16

3

4

5

6

6

A

54321

B

C

D

E

F

SCALE

APPROVED BY

CHECKED BY

SHEET NO.

TITLE

DRAWN BY

DATE

PROJECT NO.

REVISIONS

SEAL

TBPE Registeration Number 1886510260 Westheimer Rd. Suite 250 Houston, TX 77042713.429.4949www.infinitymep.com

Infinity MEP Consultants

Matrix Structural

5177 Richmond Avenue Suite 670 Houston, TX 77056713.664.0130

600 Parsippany Rd Suite 301Parsippany, NJ 07054713.576.0148

Dewberry Engineers Inc.

ISSUE FOR BID AND PERMIT

6/1

5/2

021 4

:00

:21

PM

C:\U

se

r s\b

rupp

\Docum

en

ts\H

2032

5-H

ald

or

Topsoe P

rodu

ction

Pla

nt -

ME

P_

r20

_b

rup

pY

LU

YF

.rvt

MECHANICAL PLAN -FIRST FLOOR - AREA

B

BR

NB

Approver

06/18/2021

50132460

TK

BU

ILD

ING

HA

LD

OR

TO

PS

OE

10

01

0 B

AY

PO

RT

BL

VD

.P

AS

AD

EN

A,

TX

77

50

7

M2.01B1/8" = 1'-0"

1MECHANICAL PLAN - FIRST FLOOR - AREA B

KEYNOTESKEYNOTE DESCRIPTION

1 HORIZONTAL FAN COIL UNIT LOCATED ABOVE CEILING. ROUTE 3/4" CONDENSATE TO TAIL PIECE OF LAV. PROVIDE DUCTTRANSITIONS AS REQUIRED TO MAKE CONNECTION TO UNIT. ROUTE 8" DIAMETER OUTSIDE AIR DUCT UP THRU ROOF BALANCEDTO CFM INDICATED ON SCHEDULE.

2 CONDENSING UNIT TO BE LOCATED ON CONCRETE PAD. PROVIDE MANUFACTURER'S RECOMMENDATIONS FOR CLEARANCESAROUND CONDENSING UNIT. ROUTE REFRIGERANT PIPING TO ASSOCIATED FAN COIL UNIT. MANUFACTURER TO SIZEREFRIGRANT PIPING BASED ON FINAL EQUIPMENT PLACEMENT.

3 ROOF MOUNTED EXHAUST FAN.

4 CONDENSATE DRAIN DOWN FROM ABOVE.

5 ROUTE 8" DIAMETER OUTSIDE AIR DUCT UP THRU LOW ROOF. PROVIDE WITH MOTORIZED DAMPER TO CLOSE WHEN UNIT NOT INOPERATION.

6 PROVIDE PROGRAMMABLE BUILDING STANDARD THERMOSTAT. COORDINATE EXACT FINAL LOCATION WITH ARCHITECT.

NO. DESCRIPTION DATE

GENERAL NOTESA COORDINATE FINAL LAYOUTS AND REQUIREMENTS WITH PROCESS ENGINEER PRIOR TO BID.

06/15/2021

Page 10: ARCHITECT: TK BUILDING ISSUED FOR BID & PERMIT JUNE 18, …c-air-s.com/plans/haldor_topsoe_mech_dwgs.pdf · gb-01 1 scale: view name 1/8" = 1'-0" 1/a101 1 a101 sim callout building/wall

T

T

10987654321

D

A

C

11

E

12

/1 M2.02A /1 M2.02B

A.5

5.5 7.5

A.4

4.22.9 13

B.7

C.4

10.6

6

A

54321

B

C

D

E

F

SCALE

APPROVED BY

CHECKED BY

SHEET NO.

TITLE

DRAWN BY

DATE

PROJECT NO.

REVISIONS

SEAL

TBPE Registeration Number 1886510260 Westheimer Rd. Suite 250 Houston, TX 77042713.429.4949www.infinitymep.com

Infinity MEP Consultants

Matrix Structural

5177 Richmond Avenue Suite 670 Houston, TX 77056713.664.0130

600 Parsippany Rd Suite 301Parsippany, NJ 07054713.576.0148

Dewberry Engineers Inc.

ISSUE FOR BID AND PERMIT

6/1

5/2

021 4

:00

:24

PM

C:\U

se

r s\b

rupp

\Docum

en

ts\H

2032

5-H

ald

or

Topsoe P

rodu

ction

Pla

nt -

ME

P_

r20

_b

rup

pY

LU

YF

.rvt

OVERALLMECHANICAL PLAN -

MEZZANINE

BR

NB

Approver

06/18/2021

50132460

TK

BU

ILD

ING

HA

LD

OR

TO

PS

OE

10

01

0 B

AY

PO

RT

BL

VD

.P

AS

AD

EN

A,

TX

77

50

7

M2.023/32" = 1'-0"1

OVERALL MECHANICAL PLAN - MEZZANINE

NO. DESCRIPTION DATE

GENERAL NOTESA COORDINATE FINAL LAYOUTS AND REQUIREMENTS WITH PROCESS ENGINEER PRIOR TO BID.

06/15/2021

Page 11: ARCHITECT: TK BUILDING ISSUED FOR BID & PERMIT JUNE 18, …c-air-s.com/plans/haldor_topsoe_mech_dwgs.pdf · gb-01 1 scale: view name 1/8" = 1'-0" 1/a101 1 a101 sim callout building/wall

T

87654321

D

A

C

E

/1 M2.02B

FCU-2

L-1

L-2

L-3

L-4 L-5 L-6 L-7 L-8 L-9 L-10

L-18L-19L-20L-21L-22L-23L-24L-25

RL/RS

12x6

500D

(TYP. 6)

12x6

500D

12x6

500D

(TYP. 6)

12x6

500D

28x16 20x16 12x16

3/4" COND. DRAIN

A.5

5.5 7.5

A.4

4.22.9

B.7

C.4

1 1 1 11111

1

1

1

1 1 1 1 1 1 1 1

2

3

6

A

54321

B

C

D

E

F

SCALE

APPROVED BY

CHECKED BY

SHEET NO.

TITLE

DRAWN BY

DATE

PROJECT NO.

REVISIONS

SEAL

TBPE Registeration Number 1886510260 Westheimer Rd. Suite 250 Houston, TX 77042713.429.4949www.infinitymep.com

Infinity MEP Consultants

Matrix Structural

5177 Richmond Avenue Suite 670 Houston, TX 77056713.664.0130

600 Parsippany Rd Suite 301Parsippany, NJ 07054713.576.0148

Dewberry Engineers Inc.

ISSUE FOR BID AND PERMIT

6/1

5/2

021 4

:00

:26

PM

C:\U

se

r s\b

rupp

\Docum

en

ts\H

2032

5-H

ald

or

Topsoe P

rodu

ction

Pla

nt -

ME

P_

r20

_b

rup

pY

LU

YF

.rvt

MECHANICAL PLAN -MEZZANINE - AREA

A

BR

NB

Approver

06/18/2021

50132460

TK

BU

ILD

ING

HA

LD

OR

TO

PS

OE

10

01

0 B

AY

PO

RT

BL

VD

.P

AS

AD

EN

A,

TX

77

50

7

M2.02A1/8" = 1'-0"1

MECHANICAL PLAN - MEZZANINE - AREA A

KEYNOTESKEYNOTE DESCRIPTION

1 EXTERIOR LOUVER. COORDINATE DETAILING WITH ARCHITECT. RE: DETAIL AND SCHEDULE.

2 HORIZONTAL FAN COIL UNIT LOCATED IN EXPOSED CEILING. PROVIDE WIRE-MESH SCREEN ON RETURN AIR DUCT INLET. ROUTE3/4" CONDENSATE DRAIN AS INDICATED. PROVIDE DRAIN PAN UNDER CONDENSATE DRAIN PIPE LOCATED IN ELECTRICAL ROOMWITH WATER SENSING DEVICE TO SHUT UNIT OFF AND INITIATE ALARM. ROUTE REFRIGERANT PIPING TO ASSOCIATEDCONDENSING UNIT LOCATED AT GRADE. COORDINATE EXACT LOCATION OF DUCTWORK WITH CABLE LADDERS.

3 PROVIDE PROGRAMMABLE BUILDING STANDARD THERMOSTAT. COORDINATE EXACT FINAL LOCATION WITH ARCHITECT.

NO. DESCRIPTION DATE

GENERAL NOTESA COORDINATE FINAL LAYOUTS AND REQUIREMENTS WITH PROCESS ENGINEER PRIOR TO BID.

06/15/2021

Page 12: ARCHITECT: TK BUILDING ISSUED FOR BID & PERMIT JUNE 18, …c-air-s.com/plans/haldor_topsoe_mech_dwgs.pdf · gb-01 1 scale: view name 1/8" = 1'-0" 1/a101 1 a101 sim callout building/wall

T

109

D

A

C

11

E

12

/1 M2.02A

FCU-3

L-11L-12

L-13

L-14

L-15L-16L-17

RL/RS

12x6

435D

(TYP. 4)

18x16 12x16

3/4" COND. DRAIN

2

13

B.7

C.4

10.6

11

1

1

111

3

6

A

54321

B

C

D

E

F

SCALE

APPROVED BY

CHECKED BY

SHEET NO.

TITLE

DRAWN BY

DATE

PROJECT NO.

REVISIONS

SEAL

TBPE Registeration Number 1886510260 Westheimer Rd. Suite 250 Houston, TX 77042713.429.4949www.infinitymep.com

Infinity MEP Consultants

Matrix Structural

5177 Richmond Avenue Suite 670 Houston, TX 77056713.664.0130

600 Parsippany Rd Suite 301Parsippany, NJ 07054713.576.0148

Dewberry Engineers Inc.

ISSUE FOR BID AND PERMIT

6/1

5/2

021 4

:00

:29

PM

C:\U

se

r s\b

rupp

\Docum

en

ts\H

2032

5-H

ald

or

Topsoe P

rodu

ction

Pla

nt -

ME

P_

r20

_b

rup

pY

LU

YF

.rvt

MECHANICAL PLAN -MEZZANINE - AREA

B

BR

NB

Approver

06/18/2021

50132460

TK

BU

ILD

ING

HA

LD

OR

TO

PS

OE

10

01

0 B

AY

PO

RT

BL

VD

.P

AS

AD

EN

A,

TX

77

50

7

M2.02B1/8" = 1'-0"1

MECHANICAL PLAN - MEZZANINE - AREA B

KEYNOTESKEYNOTE DESCRIPTION

1 EXTERIOR LOUVER. COORDINATE DETAILING WITH ARCHITECT. RE: DETAIL AND SCHEDULE.

2 HORIZONTAL FAN COIL UNIT LOCATED IN EXPOSED CEILING. PROVIDE WIRE-MESH SCREEN ON RETURN AIR DUCT INLET. ROUTE3/4" CONDENSATE DRAIN AS INDICATED. PROVIDE DRAIN PAN UNDER CONDENSATE DRAIN PIPE LOCATED IN ELECTRICAL ROOMWITH WATER SENSING DEVICE TO SHUT UNIT OFF AND INITIATE ALARM. ROUTE REFRIGERANT PIPING TO ASSOCIATEDCONDENSING UNIT LOCATED AT GRADE. COORDINATE EXACT LOCATION OF DUCTWORK WITH CABLE LADDERS.

3 PROVIDE PROGRAMMABLE BUILDING STANDARD THERMOSTAT. COORDINATE EXACT FINAL LOCATION WITH ARCHITECT.

NO. DESCRIPTION DATE

GENERAL NOTESA COORDINATE FINAL LAYOUTS AND REQUIREMENTS WITH PROCESS ENGINEER PRIOR TO BID.

06/15/2021

Page 13: ARCHITECT: TK BUILDING ISSUED FOR BID & PERMIT JUNE 18, …c-air-s.com/plans/haldor_topsoe_mech_dwgs.pdf · gb-01 1 scale: view name 1/8" = 1'-0" 1/a101 1 a101 sim callout building/wall

10987654321

D

A

C

11

E

12

/- --- /- ---

EF-P-1 EF-P-2 EF-P-31 1 1

A.5

5.5 7.5

A.4

4.22.9 13

B.7

C.4

10.6

6

A

54321

B

C

D

E

F

SCALE

APPROVED BY

CHECKED BY

SHEET NO.

TITLE

DRAWN BY

DATE

PROJECT NO.

REVISIONS

SEAL

TBPE Registeration Number 1886510260 Westheimer Rd. Suite 250 Houston, TX 77042713.429.4949www.infinitymep.com

Infinity MEP Consultants

Matrix Structural

5177 Richmond Avenue Suite 670 Houston, TX 77056713.664.0130

600 Parsippany Rd Suite 301Parsippany, NJ 07054713.576.0148

Dewberry Engineers Inc.

ISSUE FOR BID AND PERMIT

6/1

5/2

021 4

:00

:31

PM

C:\U

se

r s\b

rupp

\Docum

en

ts\H

2032

5-H

ald

or

Topsoe P

rodu

ction

Pla

nt -

ME

P_

r20

_b

rup

pY

LU

YF

.rvt

OVERALLMECHANICAL PLAN -

ROOF

BR

NB

Approver

06/18/2021

50132460

TK

BU

ILD

ING

HA

LD

OR

TO

PS

OE

10

01

0 B

AY

PO

RT

BL

VD

.P

AS

AD

EN

A,

TX

77

50

7

M2.03

KEYNOTESKEYNOTE DESCRIPTION

1 UPBLAST EXHAUST FAN ON ROOF.

3/32" = 1'-0"1

OVERALL MECHANICAL PLAN - ROOF

NO. DESCRIPTION DATE

GENERAL NOTESA COORDINATE FINAL LAYOUTS AND REQUIREMENTS WITH PROCESS ENGINEER PRIOR TO BID.

06/15/2021

Page 14: ARCHITECT: TK BUILDING ISSUED FOR BID & PERMIT JUNE 18, …c-air-s.com/plans/haldor_topsoe_mech_dwgs.pdf · gb-01 1 scale: view name 1/8" = 1'-0" 1/a101 1 a101 sim callout building/wall

10987654321

D

A

C

11

E

12

A.5

5.5 7.5

A.4

4.22.9 13

B.7

C.4

10.6

6

A

54321

B

C

D

E

F

SCALE

APPROVED BY

CHECKED BY

SHEET NO.

TITLE

DRAWN BY

DATE

PROJECT NO.

REVISIONS

SEAL

TBPE Registeration Number 1886510260 Westheimer Rd. Suite 250 Houston, TX 77042713.429.4949www.infinitymep.com

Infinity MEP Consultants

Matrix Structural

5177 Richmond Avenue Suite 670 Houston, TX 77056713.664.0130

600 Parsippany Rd Suite 301Parsippany, NJ 07054713.576.0148

Dewberry Engineers Inc.

ISSUE FOR BID AND PERMIT

6/1

5/2

021 4

:00

:32

PM

C:\U

se

r s\b

rupp

\Docum

en

ts\H

2032

5-H

ald

or

Topsoe P

rodu

ction

Pla

nt -

ME

P_

r20

_b

rup

pY

LU

YF

.rvt

OVERALLMECHANICAL

CEILING PLAN -FIRST FLOOR

BR

NB

Approver

06/18/2021

50132460

TK

BU

ILD

ING

HA

LD

OR

TO

PS

OE

10

01

0 B

AY

PO

RT

BL

VD

.P

AS

AD

EN

A,

TX

77

50

7

M3.013/32" = 1'-0"

1OVERALL MECHANICAL CEILING COORDINATION PLAN - FIRST FLOOR

NO. DESCRIPTION DATE

06/15/2021

Page 15: ARCHITECT: TK BUILDING ISSUED FOR BID & PERMIT JUNE 18, …c-air-s.com/plans/haldor_topsoe_mech_dwgs.pdf · gb-01 1 scale: view name 1/8" = 1'-0" 1/a101 1 a101 sim callout building/wall

SEE NOTE #4

SUPPLY DUCTCOLLAR

HAND DAMPER

FLEX DUCT MAX. 5'-0"

CEILING DIFFUSER

CEILING

FLEX DUCT SIZE SHALL MATCH NECK SIZE

OPPOSED BLADE DAMPER

TYPICAL DIFFUSER CONNECTION (SIDE OF DUCT CONNECTION)

OPPOSED BLADE DAMPER

SUPPLY DUCT MAIN

FLEX DUCT WHERE REQUIRED (MAX. LENGTH 5'-0")

FLEX DUCT SIZES SHALL MATCH NECK SIZES

SEE NOTE #4

CEILING

COLLARHAND DAMPER

CEILING DUFFUSER

ROUND TO SQUARE ADAPTOR

TYPICAL DIFFUSER CONNECTION (BOTTOM OF DUCT CONNECTION)

NOTES:

1. PROVIDE REMOTE CABLE DAMPERS FOR ALL GYP./ NON ACCESSIBLE CEILINGS.2. PROVIDE BALANCING DAMPER AT BRANCH TAKEOFF.3. PROVIDE WITH EQUAL TO TITUS "TRU RIGHT SADDLE" OR HARD RIGHT ELBOW TO ENSURE ADEQUATE AIRFLOW.4. SEAL FLEX DUCT TO METAL COLLAR WITH DUCT TAPE (NASHUA 398 OR EQUAL), INSTALL TIE-WRAP (ULINE JUMBO NATURAL

NYLON CABLE TIES) OVER DUCT TAPE. INSTALL DUCT INSULATION OVER METAL COLLAR AND SECURE WITH TIE-WRAP.

AIR

FLOW

*

AIR DUCT MAIN LOW PRESSURE SUPPLY

45°

FLOW

AIR

*-EQUALS WIDTH OF BRANCH DUCT UP TO 12". 12" FOR ALL BRANCH DUCTS LARGER THAN 12".

*

RETURN AIR BRANCH DUCT

ACOUSTIC LINING WHERE INCICATED

MAIN RETURN AIR DUCT

45°

FLOW

*45°

LOW PRESSURE BRANCH DUCT

AIR

TYPICAL LOW PRESSURE BRANCH DUCT TAKE-OFF

TYPICAL RETURN/ EXHAUST AIR BRANCH TAKE-OFF TYPICAL SUPPLY AIR BRANCH TAKE-OFF

ROUNDDUCT

FLEXIBLE ROUND DUCT AS INDICATED. (5'-0" MAX.)

SPIN COLLAR DUCT SEALER

NO EXPOSED LINER EDGES

SEE NOTE 2

*-EQUALS WIDTH OF BRANCH DUCT UP TO 12". 12" FOR ALL BRANCH DUCTS LARGER THAN 12".

*-EQUALS WIDTH OF BRANCH DUCT UP TO 12". 12" FOR ALL BRANCH DUCTS LARGER THAN 12".

ACOUSTIC LINING WHERE INCICATED

MAIN SUPPLY AIR DUCT

HAND VOLUME DAMPER

ACOUSTIC LINING WHERE INCICATED

MAIN SUPPLY AIR DUCT

HAND VOLUME DAMPER

HAND VOLUME DAMPER

HAND VOLUME DAMPER

LOW PRESSURE BRANCH DUCT

NOTES:

1. PROVIDE BALANCING DAMPER AT BRANCH TAKEOFF.2. SEAL FLEX DUCT TO METAL COLLAR WITH DUCT TAPE (NASHUA 398 OR EQUAL), INSTALL TIE-WRAP (ULINE JUMBO NATURAL

NYLON CABLE TIES) OVER DUCT TAPE. INSTALL DUCT INSULATION OVER METAL COLLAR AND SECURE WITH TIE-WRAP.

TYPICAL AFTER EACH TAKE-OFF(S) WHERE CHANGE IN DUCT. SIZE AS INDICATED

CROSS BREAK OR BEAD AS FOR DUCT

FIG. "B"

FIG. "C"

AIR FLOW

MAX. AS INDICATED (7" IN 12") ON CONTRACTING FLOW

30°

20°

FIG. "A"LARGEST DIMENSION GOVERNS CONSTRUCTION

SEAM

SEAM

AIR FLOW

SILICONE RUBBER DUCT TAPE AS MANUFACTURED BY HARDCAST.

AIRFLOW

45°

HARD DUCT CONNECTIONS ONLY. NO FLEX CONNECTIONS PERMITTED.

EXHAUST/RETURN AIR TERMINAL

ROUND BRANCH TAKEOFF

1 1/2W

USE THIS DESIGN WHERE ROUND 90 ELS ARE SHOWN ON PLANS

CL

LC

"W"

"W"

"W"

"W"

TURNING VANES

"W"

"W"

"W"

"W"

CL

LC

1 1/2W

TURNING VANES

AIR

FLOW

"W"

"W"

BRANCH

MAIN

TURNING VANES

SLOPE NOT TO EXCEED1" IN 4"

1" IN 4"SLOPE NOT TO EXCEED

RECTANGULAR DUCTROUND DUCT

AIR

FLOW

MAIN

SPLITTER DAMPER

TURNING VANES

BRANCH

DAMPER ADJUSTMENT ROD & LOCK SCREW

FLOW

AIR

ACCESS PANEL DETERMINE SIZE & LOCATION IN THE FIELD

FUSIBLE LINK

HINGE POINT

ANGLE STOP

SPRING CATCH

AIRFLOW

FLOWAIR

SPRING CATCH

ANGLE STOP

WEIGHT

1"R.

2" RADIU

S

1" 1"

1"

1"

CONNECTION LINKAGE DOUBLE ACTING

BLADES

HINGE POINT

OPERATING SHAFT FOR QUADRANT OR MOTOR.

ROUND 90° ELBOW

CONSTRUCTION OF 90° ELBOWS

SQUARE 90° ELBOW SQUARE 45° ELBOW

CONSTRUCTION OF 45° ELBOWS

ROUND 45° ELBOW

SQUARE BRANCH TAKEOFF

CONSTRUCTION OF BRANCH TAKEOFFS FROM MAIN

TYPICAL RECTANGULAR TRANSITION TYPICAL RECTANGULAR TO ROUND TRANSITION

TYPICAL SPLITTER DAMPER

HORIZONTAL VERTICAL

TYPICAL FIRE DAMPERDETAIL OF TURN VANES TYPICAL VOLUME DAMPER

INSTALLATION NOTES:

1. ALL DUCTS SHALL BE CONSTRUCTED AND ERECTED IN A NEAT AND WORKMANLIKE MANNER.

2. DUCTS SHALL BE CONSTRUCTED OF THE WEIGHTS , GAGES AND MATERIAL SHOWN IN THE SCHEDULE ON THESE DRAWINGS.

3. THE DIMENSION SHOWN FOR ALL DUCTS SHOWN IN PLAN GIVE THE WIDTH FIRST AND THEN THE HEIGHT.

4. DUCT RISERS SHOULD BE SUPPORTED BY ANGLES AT EVERY FLOOR.5. AIR TURNING VANES SHALL BE INSTALLED IN ALL ABRUPT ELBOWS TO PREVENT

TURBULENCE.6. DUCTS SHALL BE SECURELY ATTACHED TO THE BUILDING CONSTRUCTION IN AN

APPROVED MANNER.7. DIVERGING TRANSITION PIECES SHALL BE MADE AS GRADUAL AS POSSIBLE.8. INSTALL FIRE DAMPERS IN ACCORDANCE WITH UL 555.9. ACCESS PANELS SHOULD BE PLACED BEFORE AND/ OR AFTER EQUIPMENT INSTALLED IN

THE DUCT.10. DUCT AREA SHOULD NOT BE DECREASED MORE THAN 10% WHEN OBSTRUCTIONS

CANNOT BE AVOIDED, AND THEN A STREAMLINED FITTING SHOULD BE USED. 11. JOINTS AND SEAMS OF SUPPLY DUCTS SHALL BE FASTENED SECURELY AND MADE AIR

TIGHT.

USE THIS DESIGN WHERE SQUARE 90 ELS ARE SHOWN ON PLANS OR IF SPACE CONDITIONS DO NOT PERMIT INSTALLATION OF ROUND 90 ELS.

USE THIS DESIGN WHERE ROUND 45 ELS ARE SHOWN ON PLANS

USE THIS DESIGN WHERE RECTANGULAR 45 ELS ARE SHOWN ON PLANS

AIR

FLOW

MAIN

BRANCH

FUSIBLE LINK

LINTEL BY OTHERS

PROTECTIVESCREEN FRAME

CLIP ANGLE(ALL AROUND)

STORM-PROOFLOUVER

LOUVER FRAME WITHBLADE EDGE GUTTERS

WALL BY OTHERS

CAULK(ALL AROUND)

RAIN SILL

1/2" x 1/2" METAL MESH SCREEN

ISOMETRIC SIDE

WALL

WALL

SEAL WATERTIGHT

EXTERIOR LOUVER- SEE PLANS FOR SIZES

LINTELS

EXTENDED SILL

SEAL WATERTIGHT

M

MOTORIZED DAMPER

6

A

54321

B

C

D

E

F

SCALE

APPROVED BY

CHECKED BY

SHEET NO.

TITLE

DRAWN BY

DATE

PROJECT NO.

REVISIONS

SEAL

TBPE Registeration Number 1886510260 Westheimer Rd. Suite 250 Houston, TX 77042713.429.4949www.infinitymep.com

Infinity MEP Consultants

Matrix Structural

5177 Richmond Avenue Suite 670 Houston, TX 77056713.664.0130

600 Parsippany Rd Suite 301Parsippany, NJ 07054713.576.0148

Dewberry Engineers Inc.

ISSUE FOR BID AND PERMIT

6/1

5/2

021 4

:00

:33

PM

C:\U

se

r s\b

rupp

\Docum

en

ts\H

2032

5-H

ald

or

Topsoe P

rodu

ction

Pla

nt -

ME

P_

r20

_b

rup

pY

LU

YF

.rvt

MECHANICALDETAILS

BR

NB

06/18/2021

50132460

TK

BU

ILD

ING

HA

LD

OR

TO

PS

OE

10

01

0 B

AY

PO

RT

BL

VD

.P

AS

AD

EN

A,

TX

77

50

7

M6.01NOT TO SCALE

1TYPICAL DIFFUSER CONNECTION DETAIL

NOT TO SCALE2

TYPICAL LOW PRESSURE BRANCH DUCT TAKE-OFF DETAIL

NOT TO SCALE6

DUCT TRANSITION DETAIL

NOT TO SCALE3

EXHAUST/RETURN DUCT BRANCH TAKE-OFF DETAIL

NOT TO SCALE4

LOW VELOCITY DUCT DETAIL

NOT TO SCALE7

EXTERIOR LOUVER DETAIL

NO. DESCRIPTION DATE

06/15/2021

Page 16: ARCHITECT: TK BUILDING ISSUED FOR BID & PERMIT JUNE 18, …c-air-s.com/plans/haldor_topsoe_mech_dwgs.pdf · gb-01 1 scale: view name 1/8" = 1'-0" 1/a101 1 a101 sim callout building/wall

SUPPLY

CONDENSATE DRAIN

FLEXIBLE CONNECTION

HANGER ROD SUSPENDED FROM STRUCTURE

FLEXIBLE CONNECTION

RETURN

DRIP PAN WITH FLOAT SWITCH

REFRIG. LIQUID LINE

REFRIG. SUCTION LINE

AIR HANDLING UNIT

NOTE:

1. CONTRACTOR TO COORDINATE HANGER ROD INSTALLATION WITH EXISTING CONDITIONS AND STRUCTURAL ENGINEER.

DRAIN PAN

EACH DIMENSION IS EQUAL TO FAN NEGATIVE STATIC PRESSURE

UNION

REMOVABLE CAP

FULL SIZE OF DRAIN CONNECTION

APPROVED AIR GAP HEIGHT

LOCAL ROOF DRAIN, FLOOR DRAIN, OR FLOOR SINK.

6" THICK CONC. PAD - EXTEND 6" BEYOND UNIT ALL AROUND

REFRIGERANT GAUGE CONNECTION

CONDUIT - POWER AND CONTROL

REFRIGERANT LIQUID LINE WITH INSULATIONSIGHT GLASS WITH

MOISTURE INDICATOR

REFRIGERANT SUCTION LINE WITH INSULATION

BACK-SEATED REFRIGERANT VALVE

CONDENSING UNIT

2"

4"

FILTER-DRYER

FAN GUARD

FASTENING CONDENSING UNIT TO CURB

AIR FLOW

DUCT

SIDEWALL GRILLE DEPTH +1"

SIDEWALL GRILLE

PROVIDE REVERSE KNUCKLE CONNECTION

REFER TO TAP DETAIL

INSTALLED ON EXPOSED DUCT

AIR FLOW

DUCT

OUTLET SIZE

SIDEWALL GRILLEWALL

REFER TO TAP DETAIL

INSTALLED ON WALL

6

A

54321

B

C

D

E

F

SCALE

APPROVED BY

CHECKED BY

SHEET NO.

TITLE

DRAWN BY

DATE

PROJECT NO.

REVISIONS

SEAL

TBPE Registeration Number 1886510260 Westheimer Rd. Suite 250 Houston, TX 77042713.429.4949www.infinitymep.com

Infinity MEP Consultants

Matrix Structural

5177 Richmond Avenue Suite 670 Houston, TX 77056713.664.0130

600 Parsippany Rd Suite 301Parsippany, NJ 07054713.576.0148

Dewberry Engineers Inc.

ISSUE FOR BID AND PERMIT

6/1

5/2

021 4

:00

:33

PM

C:\U

se

r s\b

rupp

\Docum

en

ts\H

2032

5-H

ald

or

Topsoe P

rodu

ction

Pla

nt -

ME

P_

r20

_b

rup

pY

LU

YF

.rvt

MECHANICALDETAILS

BR

NB

Approver

06/18/2021

50132460

TK

BU

ILD

ING

HA

LD

OR

TO

PS

OE

10

01

0 B

AY

PO

RT

BL

VD

.P

AS

AD

EN

A,

TX

77

50

7

M6.02NOT TO SCALE1

HORIZONTAL FAN COIL UNIT DETAIL

NOT TO SCALE2

CONDENSATE DRAIN DETAIL

NO. DESCRIPTION DATE

NOT TO SCALE3

DX CONDENSING UNIT - SLAB MOUNTED ATGRADE

NOT TO SCALE4

TYPICAL SIDEWALL GRILLE DETAIL

06/15/2021