ARCHISHAPE 2.0 Linear MAXI · W H H1 H2 L 2 ARCHISHAPE ® 2.0 Linear MAXI Weight (g) Rated power...

7
• Please read instruction carefully before assembling and installation • Please keep instruction as reference in the future ARCHISHAPE ® 2.0 Linear MAXI

Transcript of ARCHISHAPE 2.0 Linear MAXI · W H H1 H2 L 2 ARCHISHAPE ® 2.0 Linear MAXI Weight (g) Rated power...

Page 1: ARCHISHAPE 2.0 Linear MAXI · W H H1 H2 L 2 ARCHISHAPE ® 2.0 Linear MAXI Weight (g) Rated power (W) Input current (A) Rated voltage (V) IP Maximum projected area (m2) 300mm 1000

• Please read instruction carefully before assembling and installation

• Please keep instruction as reference in the future

ARCHISHAPE® 2.0 Linear MAXI

Page 2: ARCHISHAPE 2.0 Linear MAXI · W H H1 H2 L 2 ARCHISHAPE ® 2.0 Linear MAXI Weight (g) Rated power (W) Input current (A) Rated voltage (V) IP Maximum projected area (m2) 300mm 1000

W

H H1

H2

L

2

ARCHISHAPE® 2.0 Linear MAXI

Weight(g)

Rated power

(W)

Inputcurrent

(A)

Rated voltage(V) IP

Maximum projected area

(m2)

300mm 1000 14 0.58

DC 24 66

0.021

500mm 1400 21 0.88 0.036

1000mm 2500 42 1.75 0.071

Max. connected qty.(1.5mm2 master cable)

Rated power 24V DC

300mm 14W 13 pcs

500mm 21W 9 pcs

1000mm 42W 4 pcs

Above calculation is based on 1.5mm2 cable. Please consult local sales for other calculations.Signal amplifier is required when the distance between adjacent luminaires is more than 80 meters, or more than 32 luminaires are connected.

L W H H1 H2300mm

45mm 95mm 51mm 44mm500mm1000mm

Page 3: ARCHISHAPE 2.0 Linear MAXI · W H H1 H2 L 2 ARCHISHAPE ® 2.0 Linear MAXI Weight (g) Rated power (W) Input current (A) Rated voltage (V) IP Maximum projected area (m2) 300mm 1000

D

6x35mm

90° 90°

1

2

“click”

1

2

3

ARCHISHAPE® 2.0 Linear MAXI

D

Max

300mm 100mm

500mm 300mm

1000mm 800mm

1

2

4

3

Page 4: ARCHISHAPE 2.0 Linear MAXI · W H H1 H2 L 2 ARCHISHAPE ® 2.0 Linear MAXI Weight (g) Rated power (W) Input current (A) Rated voltage (V) IP Maximum projected area (m2) 300mm 1000

Brown+ (DC)

Blue– (DC)

Female connector

Female connector

Male connectorDC 24V

IP66 conjunction box 2-pin starter cable 2-pin interconnection1000mm cable(optional)

Use end cap for final fixture in chain

18

26

11

8

ASL 2&3-pin Connector Socket End Cap CEAM259050055

ASL 2-pin DC Power Starter Cable 600 CEAM251590055

16.8

56 60050

9.5 Label

Brown: DC24V +Blue:DC24V –

9.5

ASL 2-pin DC Interconnection CAB 1000 CE AM251600055

4

ARCHISHAPE® 2.0 Linear MAXI

5A - On Off version

On Off version - Accessories

Page 5: ARCHISHAPE 2.0 Linear MAXI · W H H1 H2 L 2 ARCHISHAPE ® 2.0 Linear MAXI Weight (g) Rated power (W) Input current (A) Rated voltage (V) IP Maximum projected area (m2) 300mm 1000

ASL DC24V 5-pin Starter Cable 2mAM296210055

9.5

2000

50

ASL 5-pin Interconnection T-CABAM296180055

50

59 400

1000

ASL 5PINS Connectors 4 data Cable 0.15mAM296190055

ASL 5-pin Interconnection Cable 1mAM296220055

6.8

9.6

16.8

59 150

16.8

59 1000

ASL DC 5-pin Connector Socket End CapAM296200055

59

19.1

5-Pin Start cableAM296210055

Interconnection cableAM296220055(Options)

AS2.0 Linear Fixture 1

DC 24VInput

End CapAM296200055

DC 24V Input & DMX Input

T cableAM296180055

5PINS CONNECTORS 4 DATA CABLEAM296190055

Interconnection cableAM296220055(Options)

AS2.0 Linear Fixture 2 AS2.0 Linear Fixture n

AS2.0 Linear Fixture 1 AS2.0 Linear Fixture 2

AS2.0 Linear Fixture 2

AS2.0 Linear Fixture n

AS2.0 Linear Fixture 1 AS2.0 Linear Fixture n

AM296220055(Options)

BlueDMX –

GreenADDRESS

YellowDMX +

Black– (DC)

Red+ (DC)

Note : Do not connect the ADDRESS wire for the first fixture.

IP66 conjunction box

5

ARCHISHAPE® 2.0 Linear MAXI

5B - DMX version

DMX version - Accessories

Page 6: ARCHISHAPE 2.0 Linear MAXI · W H H1 H2 L 2 ARCHISHAPE ® 2.0 Linear MAXI Weight (g) Rated power (W) Input current (A) Rated voltage (V) IP Maximum projected area (m2) 300mm 1000

6

ARCHISHAPE® 2.0 Linear MAXI

After connecting the cables, tangle up with water-proof tapes for extra protection.

Handle the fixture with care. Do not pull or handle the lead cables and connectors.

Page 7: ARCHISHAPE 2.0 Linear MAXI · W H H1 H2 L 2 ARCHISHAPE ® 2.0 Linear MAXI Weight (g) Rated power (W) Input current (A) Rated voltage (V) IP Maximum projected area (m2) 300mm 1000

1. The luminaire should be installed and maintained by qualified electrician and wired in accordance with the latest IEE electrical regulations or the national regulations. Terminal block not included. Installation may require advice from a qualified person.

2. Make sure the products are grounded.3. The power must be OFF during installation and maintenance.4. The external flexible cable or cord of this luminaire cannot be replaced. If the cord is damaged,

the luminaire shall be destroyed.5. The light source of this luminaire can not be exchanged; if the user needs to exchange the light

source (e.g. the light source is at the end of its life cycle), then the completed luminaire has to be exchanged.

6. Installation: Surface mounted. Outdoor use. No mounting height limited.7. Make sure the products are securely installed.8. The housing might become hot during or after operation.9. No modification on the product is allowed.10. Suitable for indoor and outdoor use. Do not immerse in water.11. Not suitable for ordinary lighting in household room illumination.12. Power supply system should be equipped with SPD (Surge protection Device) accordance

with electrical regulations.13. For DMX version, reinforced insulation has been complied between LV supply and control

conductors.

WARNING:

C10449057G150657672019-07-03 www.osram.com

1. Order all power supplies / cables / connectors / controllers / signal amplifers / IP66 junction boxes separately.2. Connect luminaires to main power supply & DMX cable by IP66 junction box (purchased by customer).

Make sure the wiring is correct and reliable. Suggest to wrap the connectors by waterproofed tape for security. 3. Regular check and cleaning are required.4. Do not stare at the operating light source. The luminaire should be positioned so that prolonged staring into the

luminaire at a distance closer than 2m is not expected.5. Suggest to use shielded twisted-pair as signal cable. Terminate each DMX line with a 120 ohm resistor to get

stable DMX signal.6. DMX version requires addressing tool to address the luminaires.7. Signal amplifer is recommended when the distance between controller and the first luminaire is over 100 meters.

INSTRUCTION:

IEC 60598-1:2014

IEC 60598-1:2014/AMD1:2017

IEC 60598-2-1:1979

IEC 60598-2-1:1979/AMD1:1987

�欧司朗(中国)照明有限公司 �广东省佛山市工业北路1号� 邮编: 528000 客服热线: 400 882 1836 OSRAM CHINA LIGHTING LTD. No. 1 North Industrial Road, Foshan, Guangdong. Postal code: 528000 www.osram.com.cn PT OSRAM Indonesia COWELL Tower 8th Floor Jl. Senen Raya No. 135 Jakarta Pusat 10410 www.osram.com บริษัท ออสแรม (ประเทศไทย) จำ�กัด อ�ค�รช�ญอิสสระท�วเวอร์ 2 ชั้น 19 2922/251 ถนนเพชรบุรีตัดใหม่ แขวงบ�งกะปิ เขตห้วยขว�ง กรุงเทพมห�นคร 10310 www.osram.com

OSRAM (Malaysia) Sdn Bhd (Company No: 491867 X) L8-02, 8th Floor, Tropicana City Office Tower, No.3 , Jalan SS20/27, 47400 Petaling Jaya, Selangor, Malaysia www.osram.com OSRAM Lighting Private Ltd. 1st Floor, IFFCO, Surinder Jhakhar Bhavan, Plot No. 3, Sector-32, Gurgaon-122001, Haryana, India Consumer care cell (Address as per above) Toll free number: 18004190426 E-mail id: [email protected] www.osram.com

주식회사 오스람 서울시 강남구 삼성로 554 예성빌딩 3 층 (06165) AS: 080 349 0365 www.osram.kr

OSRAM Lighting Pte Ltd 988 Toa Payoh North # 03-01 / 07 / 08 Singapore 319002 www.osram.com Traxon Technologies Ltd. 213 Wireless Centre, 3 Science Park East Avenue, Science Park, Shatin, New Territories, Hong Kong Phone: +852 2943 3488 www.osram.com OSRAM GmbH Karl-Schurz-Straße 38 33100 Paderborn Germany www.osram.com