Arc-Resistant Mesium Voltage Switchgear/MCC...

2
Arc-Resistant Medium Voltage Switchgear / MCC Transition Section Easy-to-Connect Medium Voltage Solution Extends Compliant Protection Extending arc-resistant protection across your medium voltage motor control systems just got easier – thanks to the collective efforts of Rockwell Automation and ABB. A new arc-resistant switchgear/ MCC transition section allows medium voltage Allen-Bradley® CENTERLINE® 1500 ArcShield™ motor control centers (MCCs) to seamlessly connect to the ABB SafeGear® family of switchgear. Designed exclusively for use with medium voltage ArcShield and SafeGear products, the transition section eases installation and helps protect personnel and equipment by maintaining a consistent arc-resistant design across your switchgear/motor control system. Until now, a common way to maintain IEEE-compliant arc-resistance was to cable the feeder breaker in the switchgear to the power bus of the ArcShield MCC. The arc-resistant transition section, manufactured by ABB, replaces complex cabling and allows the main bus of the switchgear to be directly bolted to the power bus of the MCC. Both the ArcShield MCC and SafeGear switchgear include top-mounted plenums as part of their arc-resistant offerings. The plenums redirect energy out of the top of the unit and away from personnel in the event of an arc fault. To complement this design, the transition section also includes a top-mounted plenum connection as standard. The integrated solution is compliant to the IEEE C37.20.7 standard and provides Type 2B protection. Features and Benefits • UL-certified transition section is compatible with all CENTERLINE 1500 ArcShield MCCs. Enables seamless connectivity – and arc-resistance – across an integrated Allen-Bradley motor control and ABB switchgear system. (IEEE C37.20.7, Type 2B compliant) Reduces overall installation costs while maintaining a consistent arc-resistant design system wide. • Top-mounted ventilation assembly systems redirect energy away from personnel in the event of an arc fault. Suitable for left or right and back-to-back MCC extensions. • Various switchgear configurations supported such as main, main-tie-main and feeder applications. Rockwell Automation and ABB collaborate to provide a more cost-effective and efficient system.

Transcript of Arc-Resistant Mesium Voltage Switchgear/MCC...

Page 1: Arc-Resistant Mesium Voltage Switchgear/MCC …literature.rockwellautomation.com/idc/groups/literature/...Arc-Resistant Medium Voltage Switchgear / MCC Transition Section Easy-to-Connect

Arc-Resistant Medium Voltage Switchgear / MCC Transition Section

Easy-to-Connect Medium Voltage Solution Extends Compliant Protection

Extending arc-resistant protection across your medium voltage motor control systems just got easier – thanks to the collective efforts of Rockwell Automation and ABB. A new arc-resistant switchgear/MCC transition section allows medium voltage Allen-Bradley® CENTERLINE® 1500 ArcShield™ motor control centers (MCCs) to seamlessly connect to the ABB SafeGear® family of switchgear.

Designed exclusively for use with medium voltage ArcShield and SafeGear products, the transition section eases installation and helps protect personnel and equipment by maintaining a consistent arc-resistant design across your switchgear/motor control system.

Until now, a common way to maintain IEEE-compliant arc-resistance was to cable the feeder breaker in the switchgear to the power bus of the ArcShield MCC. The arc-resistant transition section, manufactured by ABB, replaces complex cabling and allows the main bus of the switchgear to be directly bolted to the power bus of the MCC.

Both the ArcShield MCC and SafeGear switchgear include top-mounted plenums as part of their arc-resistant offerings. The plenums redirect energy out of the top of the unit and away from personnel in the event of an arc fault. To complement this design, the transition section also includes a top-mounted plenum connection as standard.

The integrated solution is compliant to the IEEE C37.20.7 standard and provides Type 2B protection.

Features and Benefits• UL-certified transition

section is compatible with all CENTERLINE 1500 ArcShield MCCs.

• Enables seamless connectivity – and arc-resistance – across an integrated Allen-Bradley motor control and ABB switchgear system. (IEEE C37.20.7, Type 2B compliant)

• Reduces overall installation costs while maintaining a consistent arc-resistant design system wide.

• Top-mounted ventilation assembly systems redirect energy away from personnel in the event of an arc fault.

• Suitable for left or right and back-to-back MCC extensions.

• Various switchgear configurations supported such as main, main-tie-main and feeder applications.

Rockwell Automation and ABB collaborate to provide a more cost-effective and efficient system.

Page 2: Arc-Resistant Mesium Voltage Switchgear/MCC …literature.rockwellautomation.com/idc/groups/literature/...Arc-Resistant Medium Voltage Switchgear / MCC Transition Section Easy-to-Connect

Publication 1500-PP001A – October 2016 Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.

Allen-Bradley, ArcShield, CENTERLINE, Listen. Think. Solve., and Rockwell Software are trademarks of Rockwell Automation, Inc. SafeGear is a trademark of ABB. Trademarks not belonging to Rockwell Automation are property of their respective companies.

Compact Design. Seamless Solution.

The ABB transition section features a compact footprint and is compatible with all CENTERLINE 1500 ArcShield MCC configurations, from single line-up to back-to-back options.

Voltage (kV)Main Bus Continuous Current (A)

Short Circuit CurrentArc Resistant Accessibility Type

Arc Fault Duration

5 to 7.2kV 1200A, 2000A, 3000A 25, 31.5, 40, 50 2, 2B 10 cycles

Heavy-Duty Structural Components• Durable epoxy powder paint coating.• Generous working space.• Mounting channels ease installation.• Modular design simplifies maintenance.

Isolated Power Cell Compartment• Integrated non-load break isolation

switch provides visual isolation and dead-front protection.

• Ample space for isolated load cable connections for added safety.

• Top or bottom cable entry/exit.

Separate Low Voltage Compartment• Provides access to low

voltage equipment. • Personnel continue to be shielded

even when the low voltage door is open for maintenance.

Transition Section Ventilation Assembly• Top-mounted plenum connection redirects energy away from personnel

in the event of an arc fault. • Provides consistent ventilation method throughout system.

The integrated solution is IEEE C37.20.7, Type 2B compliant.

Transition Piece Bussing• Allows the main bus of the

switchgear to be directly bolted to the power bus of the MCC.

• Replaces complex cabling.