Arc Flash English

download Arc Flash English

of 40

Transcript of Arc Flash English

  • 7/30/2019 Arc Flash English

    1/40

    Divisin Industria

    Su xito es nuestro objetivo

    ELECTRICAL ARC FLASH

    HAZARD STUDY

    APRIL 2008

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    2/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlash

    Estudio de Riesgos

    VIDEO LIBERATION OF ENERGY

    Study of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    3/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlash

    Estudio de Riesgos

    Electrical Arch

    We are exposed?

    Applicable Regulations

    Risks

    Incidents

    Arc Flash Study

    AGENDA

    Topics to Covering:

    Study of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    4/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlash

    Estudio de Riesgos

    ArcFlash

    Whats this?

    Electrical

    Accident

    Traffic of current

    across the body for

    ArcFlash

    Direct contact

    Indirectcontact

    It is a short circuit across the air, produced when :

    The insulation between two energized drivers collapses

    The same between a wire and earth, provoking an explosion for theliberation of energy

    Study of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    5/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlash

    Estudio de Riesgos

    VIDEO II ARC in 500 kV

    Study of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    6/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    Accidents of ArcFlashWhere they can happen ?

    Distributions

    Panels

    MV / LV

    CenterCenter

    Control ofControl of

    EnginesEngines

    ElectricalElectrical

    EnginesEnginesAreasAreas withwith

    highhigh

    temperaturestemperatures

    Areas with HighHigh

    Risk of OccurrenceRisk of Occurrence

    Study of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    7/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    Our Offer

    His Purpose .

    To minimize the ocurrence and consequence of accidents

    for ArcFlash

    To determine reliable procedures of operation

    To define levels of appropiate PPE

    To normalize a program of permanent training

    The PurposePurpose of

    Our StudyOur Study

    Study of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    8/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    WE ARE EXPOSED?

    WE AREEXPOSED?Study of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    9/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    WE ARE EXPOSED?

    Isnt this a common situation in your plant?

    Study of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    10/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    WE ARE EXPOSED?

    Isnt this a common situation in your plant?

    Study of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    11/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    WE ARE EXPOSED?

    Isnt this a common situation in your plant?

    Study of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    12/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    ARC FLASH REASONS

    The contact with parts under voltage for fall of tools

    Insulations fault

    Overvoltage

    Dirt

    Corrosion

    Condensation

    Study of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    13/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    NORMS

    NORMSStudy of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    14/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    ARCFLASHApplicable Regulations

    Applicable Regulations :

    Study of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    15/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    ARCFLASHApplicable Regulations

    Applicable Regulations :

    NFPA 70E Part II Articles 110 and 130

    require a flash hazard analysis be performed

    to protect qualified electrical personnel

    National Electrical Code NFPA 70 Article

    110.16 requires equipment be marked to warnpersonnel of arc flash hazards

    Study of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    16/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    OSHA 29CFR1910.269(I)(6) discussesappropriate PPE apparel to protect against

    arc flash hazards

    The 2004 s version of IEEE 1584a

    provides precise methods for ArcFlash 's

    calculation.

    Procedures and safeties measurements specified

    by each company

    ARCFLASHApplicable Regulations

    Applicable Regulations :

    Study of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    17/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    RISKS

    RISKSStudy of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    18/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    Produce thermal energy that is released during a faultand is a function of:

    Available fault current and system voltage

    Distance from fault

    Clearing time of protective device

    May generate higher energy at lower system voltages

    (due to longer time arc fault current duration)

    Electrical Arc Flash Hazards

    Study of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    19/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    TYPES OF RISKS FOR ARC FLASH

    There are principally five ways in which an electrical

    ArcFlash can to cause damage and even the death:

    Thermal Risk

    Risk of Pressure

    Risk of Hearing

    Risk for Missiles

    Risk for Inhalation

    Study of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    20/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    ARCO ELECTRICO

    Waves of Pressure

    Steam of Copper:

    Occurred to

    Steam It expandsto factor of

    67.000 times

    Molten Metal

    Intense Light

    Warm air

    Rapid expansion

    20.000C

    Missil

    Waves of sound

    Study of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    21/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    INCIDENTS of ARCFLASH

    INCIDENTSStudy of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    22/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    INCIDENTES POR ARCFLASH

  • 7/30/2019 Arc Flash English

    23/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    INCIDENT for ARCFLASH

    ArcFlash s Incident

    System of 480Volt

    22,600 Amper Symmetrical Current

    Panel of Motors Control

    It comes out of 6 cycles (0.1 sec)

    Study of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    24/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

  • 7/30/2019 Arc Flash English

    25/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    RESULT OF AN ACCIDENT FORARCFLASH

    Study of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    26/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    INCIDENT for ARCFLASH

    480 Volt System

    22,600 22,600A Symmetrical Current

    Panel of Motors Control

    Limiter equipment with < cycle of operation (.0083 sec).

    To notice that the exhaust will have to be kept in the range

    of limit of current

    INCIDENT for ARCFLASH

    Study of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    27/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    VIDEO

  • 7/30/2019 Arc Flash English

    28/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    VIDEO

    ARC FLASH s INCIDENTStudy of Risks

    Industry Division

    Your success is our aim

    VIDEO

  • 7/30/2019 Arc Flash English

    29/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    VIDEO

    Study of Risks

    Industry Division

    Your success is our aim

    AGENDA

  • 7/30/2019 Arc Flash English

    30/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    AGENDA

    ARC FLASHSTUDY

    Study of Risks

    Industry Division

    Your success is our aim

    WHAT IS A STUDY OF RISK FOR ARC FLASH?

  • 7/30/2019 Arc Flash English

    31/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    WHAT IS A STUDY OF RISK FOR ARC FLASH?

    Definition:

    The NFPA 70E defines a study ofrisks for ArcFlash as :

    A study where is investigated the potential exhibition

    of a workman to the energy caused by an electrical

    arch

    To anticipate injuries ,

    With the aim of:

    To determine sure procedures of operation ,

    Levels of appropriate PPE .

    Study of Risks

    Industry Division

    Your success is our aim

    WHAT IS THE MINIMAL DISTANCE OF

  • 7/30/2019 Arc Flash English

    32/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    PROTECTION ?

    Definition:

    The NFPA 70E defines a minimal distance of protection as:

    Distance, from the critical point, inside which aDistance, from the critical point, inside which a

    person can suffer burns of second degree due toperson can suffer burns of second degree due to

    an accident for Arc Flashan accident for Arc Flash ..

    Study of Risks

    Industry Division

    Your success is our aim

    PPE as cal/cm2

  • 7/30/2019 Arc Flash English

    33/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    PPE as cal/cm2

    PPE Selection

    Range of Calculated Incident

    Energy (cal/cm)

    Clothing

    Class No. Clothing Description, (No. of Layers)

    Total Weight

    (oz/yd)

    0 2 0 Untreated Cotton (1) 4.5 7

    2 - 5 1 FR Shirt and Pants (1) 4.5 - 8

    5 - 8 2A Cotton Underwear plus FR Shirt and Pants (2) 9 - 12

    5 - 16 2B FR Underwear plus FR Shirt and Pants (2) 10 - 14

    8 - 25 3

    Cotton Underwear plus FR Shirt and Pants plus

    FR Coverall (3) 16 - 20

    25 - 40 4Cotton Underwear plus FR Shirt and Pants plus

    Double Layer Switching Coat (4)24 - 30

    Protective Clothing Guidelines, from Predicting Incident Energy to Better Manage the Electric Arc Hazard on 600-

    V Power Distribution Systems,Table III, IEEE Transactions on Industry Applications, J an./Feb. 2000

    Proposed Protective Clothing Classes FR Clothing System

    Study of Risks

    Industry Division

    Your success is our aim Flash hazard label

  • 7/30/2019 Arc Flash English

    34/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    (one per analysis point)

    Study of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    35/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    Customer to Provide:

    One line diagram of power delivery

    system

    Current copy of power system short

    circuit study and coordination study

    Single point of contact to establish each

    analysis point with our power systems

    engineer

    Input on typical working distances

    desired for each location or default toapplicable standards

    Purchase order authorizing Siemens to

    proceed

    Electrical Arc Flash Hazard Study

    Study of Risks

    Industry Division

    Your success is our aim

    SUMMARY

  • 7/30/2019 Arc Flash English

    36/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    SUMMARY

    Siemens Solutions :

    Step #2: The short circuit study of the energy system.

    Step #3: Analysis of the current state of the protection system

    Step #4: Coordination study of the protection system.

    Step #1: Generation/Review of unifilar complete of the plant

    Step #5: Electrical Arc Flash Hazard Study.

    Step #6: Identify equipment locations that exceed available

    PPE ratings

    Step #7: Presentation of the Program of Electrical Security

    Step #8: Annual maintenance

    Your success is our aimYour success is our aim

    Study of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    37/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    Sample of Customer Deliverable :

    Electrical Arc Flash Hazard Study

    Arc Energy calculations

    Example Customer Summary of Incident Energy CalculationsIncident Energy in cal/cm2 and Working Distance

    Marzo 18, 2004Voltage

    Normal

    Operation

    Normal

    Operation

    Working

    Distance

    Arc Flash

    Boundary

    Location kV J/cm2 cal/cm2 inches feet

    12.47 kV Main Switchgear 12,47 129,2 30,9 36,0 84

    Unit Sub #1 480 V Main Breaker 0,48 474,4 113,4 24,0 43

    Unit Sub #1 480 V Bus 0,48 55,3 13,2 24,0 10MCC A 0,48 84,1 20,1 12,0 5

    MCC B 0,48 64,5 15,4 12,0 4

    Panel 16 0,48 52,5 12,5 12,0 4

    Study of Risks

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    38/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    Electrical Arc Flash Hazard Study

    Study of Risks

    Customer Benefits

    Reduced risk of employee injury or death due to arc flashhazards

    Possible revisions to customer system protection to limit

    equipment damage Provides critical safety information for subcontractorsentering facility

    Possible reduction in workers compensation andinsurance claims

    Demonstrates company effort to satisfy OSHA and NFPAregulations

    Industry Division

    Your success is our aim

  • 7/30/2019 Arc Flash English

    39/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    A BENEFICIAL RELATION

    Thank you very much for your attention.

    Study of Risks

    Industry Division

    Your success is our aim

    ENERGY CONTACTS inARGENTINA Arc Flash

  • 7/30/2019 Arc Flash English

    40/40

    Divisin Industria

    Su xito es nuestro objetivo

    ArcFlashEstudio de Riesgos

    ARGENTINA Arc Flash

    Pablo Donajger

    [email protected]

    0054 - 011 - 4738 7333

    Pablo David

    [email protected]

    0054 011 - 4738 7209Study of Risks

    Industry Division

    Your success is our aim

    mailto:[email protected]:[email protected]:[email protected]:[email protected]