Aqua Mon 4000 Ph Red Ox Analyser

download Aqua Mon 4000 Ph Red Ox Analyser

of 4

Transcript of Aqua Mon 4000 Ph Red Ox Analyser

  • 7/31/2019 Aqua Mon 4000 Ph Red Ox Analyser

    1/4

    Aquamon 4000

    pH/RedoxTransmitter

    and Controller

    Your Process, Our Analytics

    Specialists in Process Efficiency and Energy Conservation

  • 7/31/2019 Aqua Mon 4000 Ph Red Ox Analyser

    2/4

    Menu-driven program that simplifies set-up.

    Built-in memory backup to ensure that calibration and otherinformation are not erased if power supply fails.

    Push-button for calibration and electrode offset adjustment fromthe keypad.

    Automatic temperature compensation (ATC).

    Manual temperature compensation setting without the ATC probe,with independent setting for calibration and process temperature.

    Two galvanically isolated current outputs 0/4...20mA

    0 to 1999 seconds time delay adjustment on all relays minimizes false alarms.

    Software selectable, two modes - pH or ORP measurement.

    Special symmetrical configuration mode to facilitate operating inenvironments with electrical interference. Custom pH or ORP sensorsare available with the potential matching pin for symmetrical modemeasurement.

    In the ORP mode, the Aquamon 4000 is able to measure in mV or as% concentration, with independent calibration modes. All parameterscan be operated in symmetrical or asymmetrical mode.

    Push button pH calibration facility. Calibration buffer sets include US,NIST and DIN standards. Electrode condition is updated and displayedafter each calibration.

    For applications where Hydrofluoric (HF) acid is present, eitherAntimony or HF-resistant glass electrodes must be used.

    When Antimony electrodes are used, select 'Antimony' electrodeoption from controller menu to download relevant Antimonyelectrode data.

    Separately adjustable high and low set-point hysteresis (dead bands)prevent chattering of relays around the set points.

    Asymmetrical/symmetrical input for pH/ORP mode of operation.

    Three control modes: limit controller, P controller and PI controller(P/PI controller as pulse length or pulse frequency).

    Large dual display LCD for easy reading with clear multipleannunciators, alarm status, operational and error messages.

    Two switching contacts as set-point relays.

    Separate alarm relay alerting you to set point limits exceeded for acertain time and if the Pt100/Pt1000 wires are broken ordisconnected during the ATC function.

    Wash relay.

    Hold function to freeze output current (0/4...20mA) andrelease control relays.

    LED indicators signal control activities to visually monitorcontroller status from a distance.

    Protection against electromagnetic interference.

    Back lighted and UV light protected LC display

    Features

    The Forbes Marshall Aquamon 4000 is used for measuring pH or ORP

    and temperature values. The pH or ORP values can be measured using

    proportional or limit control. The controller is available in two versions,

    one for panel mounting and one for wall mounting in an enclosure. The

    controller can be used for applications such as water treatment and

    monitoring, galvanic-decontamination, chemical processing, food

    processing, clean or wastewater control and neutralization processes.

  • 7/31/2019 Aqua Mon 4000 Ph Red Ox Analyser

    3/4

    Dimensions and Connections

    66.5

    [2.6

    2]

    21.5

    [8.5

    ]

    6[.24]

    90[3.54]

    90[3.5

    4]

    Unit: MM[Inch]

    80[3.15]

    Holes for postmounting (4X)

    Holes for wallmounting (2X)

    144[5.67]

    78[3.07]

    39[1.54]approx.

    14[.55]

    144[5

    .67]

    Pg13.5(3 pcs) For Pg 13.5 cable glands

    57.8[2.28]

    24[.94]

    111.50[4.39]

    27.5[1.08]

    84[3.30] 29[1.14]Max. 80

    1-22 [0.03 - 0.87]

    Seal gasket

    Threaded rod for panel mounting

    Panel Mount Drawing (All measuurements in mm)

    Useful 12V DC output

    from the controller

    powers peripheral

    wash mechanism,

    preamplifiers, etc.

    Wash relay allows automatic,

    periodical cleaning of sensors

    used in conjunction with

    Wash program

    Detachable connectors for easier wiring.

    Independent Relay A and B

    allows combination of Hi

    andLo settings.

    HOLD terminals allow for pH/

    ORP Master-slave operations

    (pH analyzer controls ORP

    analyzer only under controlled

    pH values)

    Single-Pole-Double-Throw

    Alarm relay for fail-safe

    operations. When power

    supply to the controller is

    broken, the alarm relayactivates.

    Automatic Temperature

    Compensation with 2 or

    3 wire Pt 1000 or Pt 100

    temperature sensors.

    3-wire system minimizes

    errors from the tem-

    perature sensor and

    cables.

    View temperature values

    in degree Celsius or

    degree Fahrenheit.

    Manual Temperature

    Compensation offers

    independent input of

    process and calibration

    temperatures.

    Dual 4-20 mA scaleable

    outputs for measured

    parameter and temperature.Unique Out-of-range

    current setting at 22 mA

    differentiates normal

    readings from Out-of-

    range values.

    Liquid ground (potential matching

    pin) for symmetrical operations

    (pH / ORP controllers only)

    Unit: MM[Inch]Panel cut out

    92 +0.5 [3.62 +.02]

    92+0.5

    [3.6

    2+.0

    2]

    Flat gasket 1mm [0.4](to be inserted by customer)

    96[3.7

    8]

    92[3.6

    2]

    56[2.2

    0]

    32[1.2

    6]

    Max. 180 [7.09]

    Max. 45 [1.77]

    Wall Mount Drawing (All measuurements in mm)

    Wall Mount Opening

  • 7/31/2019 Aqua Mon 4000 Ph Red Ox Analyser

    4/4

    Forbes Marshall Pvt. Ltd.A-34/35, MIDC, Industrial Estate, 'H' Block, Pimpri, Pune - 411 018. India.Tel.: 91(0)20 - 27442020 Fax: 91(0)20 - 27442040E-mail: [email protected]

    Branches : Ahmedabad, Alibag, Bangalore, Bhopal, Chandigarh, Chennai, Coimbatore, Delhi,Hyderabad, Indore, Jamshedpur, Kolkata, Lucknow, Madurai, Mumbai, Nagpur, Navi Mumbai,Pune, Surat, Vadodara, Visakhapatnam

    Website : www.forbesmarshall.com

    Subject to change without notice FM CIG | Analytical | Aquamon4K | Rev1 | 0708 | Solutions

    R

    pH Resolution 0.01 pH

    Accuracy 0.01 pH

    Range 0 to 100% or -1000 to 1000 mV

    mV Resolution 0.1% or 1 mV

    Accuracy 1 mV

    Range -9.9 to 125 C (15.0 to 257.0 F)

    Resolution 0.1

    Temperature Relative Accuracy 0.5 C ( 1.0 F)

    Sensor Pt100 / Pt1000 (jumper selectable); 2 or 3 wire

    Compensation Automatic ( 10 C / 18 F offset adjustment) / Manual

    Function Limit / P / PI Control (Pulse Length or Pulse Frequency)

    Integral time 0 to 999.9 minutes

    Adjustable period with pulse length controller 0.5 to 20 sec.

    Adjustable period with pulse frequency controller 60 to 120 pulses / min

    Set-Point and Pickup / Dropout delay 0 to 1999 seconds

    Controller Functions Wash cycle 0.1 to 199.9 hours

    Wash duration 1 to 1999 seconds

    Switching pH Hysteresis 0.1 to 1 pH

    Switching ORP Hysteresis 1 to 10.0 % / 10 to 100 mV

    Contact Outputs, Controller 1 SPDT; 3 SPST relays

    Switching Voltage/Current/Power Max 250 VAC / Max 3A / Max 600 VA

    Function (switchable) Latching / pulse

    Alarm Functions Pickup delay 0 to 1999 seconds

    Switching Voltage/Current/Power Max 250 VAC / Max 3A / Max 600 VA

    Display LCD UV coat, backlit 14 segments display with symbols for status information

    Backlight On/Off selection with four level of brightness control

    Electromagnetic Compliance Emitted Interference EN 61 326

    (EMC) Specifications Immunity to Interference EN 61 326

    Environmental Conditions Ambient Temp. Operating Range -10 to 50 oC (14 to 122 oF)

    Rel. Humidity 10 to 95% (non-condensing)Input 80 to 250 VAC/DC 48/62 Hz

    Power Supply Main Fuse 250 mA anti-surge

    Pollution Degree 2

    Transient Overvoltage category II

    Signal Output Two 0/4 to 20 mA outputs for pH/mv and temperature, galvanically isolated

    Electrical Data Load Max.600

    and Connections pH / ORP Input Screw Terminals

    Connection terminal Wall mount (2 x 3-pins; 8-pin, 9-pin & 13-pin terminal blocks)

    Panel mount (1 x 3-pin; 1 x 9-pin & 1 x 19-pin terminal blocks)

    Dimensions (W x H x D) Wall Mount 144 x 144 x 111.5 mm (5.67 x 5.67 x 4.39 inch)

    Panel Mount 175 x 96 x 96 mm ( 6.89 x 3.78 x3.78 inch)

    Mechanical Weight Wall Mount 745g (unit); 1100g (boxed)Specifications Panel Mount 550g (unit); 950g (boxed)

    Material Wall Mount PBT

    Panel Mount ABS

    Insulation Wall Mount NEMA 4X, IP 65

    Panel Mount IP 54 (front) , IP 40 (housing)

    Ordering Information Wall mounted pH transmitter AQUAMON 4000 W

    Panel mounted pH transmitter AQUAMON 4000 P

    ange -2.00 to 16.00 pH

    Sr. No. Description Code

    1.

    2.

    Specifications