Approved for Construction BPS.15-22369.CO M.COM …...f.e. f.e. f.e. f.e.c. f.e. a302 2 a301 2 11 h...
Transcript of Approved for Construction BPS.15-22369.CO M.COM …...f.e. f.e. f.e. f.e.c. f.e. a302 2 a301 2 11 h...
F.E
.
F.E.
F.E
.
F.E.C.
F.E.
A302
2
A301
2
11
H
B
G
F
D
A.1
2
A401
2
A401
1
A401
1
A401
STAIR 2
S2-200
2
A301
3
A302
1
A302
3
ELECT
E200 E200
1
A502
2
A504
2
A502
3
A505A301
5
1
A5032
A503
3
A503
3
A504
A301
6
A301
4
1
A505
2
A505
2
A501
1
A501
STAIR 1
S1-200
S1-200
TE200
TENANT
TE200
1 3 4
A
J
5
7 6 8
12
910
C
EA651
2A653
2
A6522
3
A501
1b
A501
A1212
2.2
J.2
F.2
S2-2
00
4
A552
3
A502
A1911
J.1
F.3
H.8
0.9
SF7
SF7
SF7
SF5.2
SF4.2
SF3.2
SF2.2
SF7CSF7B
SF7A
SF1.2
SF7SF7SF7
SF11.2
SF10.2B
SF9.2
SF10.2A
SF14
SF10
SF14
SF14
SF10
SF14
SF13
SF10
SF13
SF12 SF12
SF19.2
TE
201
2'-1
0"1'-0"
5'-3 1
/2"
18'-0"
26'-8"
26'-1
1"
21'-6 1
/2"
4'-5"
3'-3"
5'-4"
2'-4"
2'-4"
2'-4"
2'-4"
3'-3"
2'-1"
3'-3" 1'-5" 4'-6"
3'-0"
2'-0" 2'-0"
2'-0 3/4"
2'-1 1/4" 2'-0"
8'-1 1/2" 25'-4" 2'-0"2'-0" 25'-4" 2'-0"2'-0" 25'-4"
1'-10 1/2"
2'-0" 23'-4"
2'-11 1/2" 16'-9" 3'-5 1/4" 14'-2 3/4" 3'-0" 26'-4" 29'-4" 29'-2 1/2"
1 2'-5"
17'-11"
3'-1"1'-7"
3'-1"
2'-0"9'-4"
3'-1"
2 '-8"
2'-0
"
3'- 1
1 1
/4"
26'-4
"4'-0
"9'-4
"18
'- 1"
22'- 0
"
19'- 4
"3
'- 11 1
/ 4"
29'- 7
"
14'- 9
3/4
"
3'-3"
1' -5
"14'- 4
"4' -8
"1
7'- 4
"4
'-8"
14'- 4
"
2 '-0"2'-8"
25'-4"
2'-4"2'-4"
25'-4"
2'-4"2'-4"
25'-4"
2'-4"
3'-3" 1'-5" 13'-4" 2'-0"2'-0" 13'-4" 2'-4" 2'-4"2'-8 1/4" 17'-4 1/2" 3'-3 1/4"
40'-0" 23'-4"
3B
1 4'-4
3/4
"4'-0
"
8'-5 3/8"7'-3 3/4"
12'-11 9/16" 2'-3 3/16"
2'-5 1/4"
6'-4 15/16"7 5/8"
11 3
/8"
8'-1
5/8
"
3'-10 1
/16"
12'-1 3
/8"
3B
S4
S4
S4 3'- 7
3/8
"
3'- 7
7/1
6"
1 0'-11"
19'-7 3/4"10'-0 1/2"
18'-2 3/4"
2 0'-0
1/2
"
5'- 3
1/4
"
18'-8"
6'-9"
7'-0"
14'-6 1
/2"
5'-0 1
/4"
10'-4 1/4" 10'-0 3/4" 9'-3" 7'-0"
2'-0 3/8"
2'- 8
3/4
"
2'- 7
1/4
"
11'-9 1
/4"
10'-5 3
/4"
GENERAL NOTES - FLOOR PLAN1. ALL DIMENSIONS ARE TO FACE OF WALL (UNLESS NOTED
OTHERWISE).SEE STRUCTURAL DRAWINGS FOR LOCATIONS OF ALL STEELREINFORCING IN WALL & FLOOR CONSTRUCTION.SEE FINISH SCHEDULE FOR ADDITIONAL INFORMATION OF LOCATIONSAND TYPES OF FINISH MATERIALS.SEE ELEVATIONS AND STRUCTURAL DRAWINGS FOR LOCATIONS OFEXPANSION & CONTROL JOINTS. CONTRACTOR SHALL PROVIDEADDITIONAL INTERIOR CONTROL JOINTS AS REQUIRED TO COMPLYWITH MAXIMUM SPACING REQUIREMENTS IN SPECIFICATIONS ANDNATIONAL MASONRY INSTITUTE. SEE DETAILS ON AXXX.MECHANICAL & ELECTRICAL EQUIPMENT SHALL BE ON HOUSEKEEPINGPADS. PADS ARE TO PROVIDED BY THE TRADE SUPPLYING THEEQUIPMENT. SEE MECHANICAL AND ELECTRICAL DRAWINGS FORADDITIONAL INFORMATION. WORK TO BE COORDINATED THROUGHTHE GENERAL TRADES CONTRACTOR. PADS 4" MIN. 4" THICK W/W.W.F., UNLESS NOTED OTHERWISE).SEE G SERIES SHEETS FOR WALL TYPE CONSTRUCTION.PROVIDE AN 24" X 36" FIRE RATED ACCESS PANEL PER FLOOR AT ALLKITCHEN GREASE SHAFT LOCATIONS AND EVERY OTHER FLOOR FORALL OTHER SHAFT LOCATIONS. ACCESS PANELS TO FACE THE PUBLICCORRIDOR SIDE. COORDINATE MOUNTING HEIGHT WITH ARCHITECT INTHE FIELD.DO NOT RUN PIPELINE, CONDUITS OR ANY DEVICES INTO THE SHAFTASSEMBLIES. SHAFT ASSEMBLIES TO REMAIN FOR THE SOLEPURPOSE OF THE MECHANICAL DUCTS.ELEVATION 810.00 EQUALS 100'-0"INSTALL FIRE EXTINGUISHER SO THE INTEGRITY OF THE RATED WALL ISMAINTAINED. CONTINUE THE TYPE X GYPSUM BOARD ASSEMBLYBEHIND THE FIRE EXTINGUISHER CABINET.SEE A600 SERIES SHEETS FOR UNIT LAYOUT INFORMATIONALL WOOD SILL PLATES IN WALLS AT PODIUM LEVEL TO BE PRESSURETREATED.EXTERIOR BEARING WALLS TO BE 1 HOUR RATED PER U.L.# U364.REFER TO STRUCTURAL SHEETS FOR BEARING WALL CONDITIONS.COORDINATE SHAFT WALL ALIGNMENT WITH ARCHITECT TO MAINTAINREQUIRED RATING IN ADJACENT WALLS.
2.
3.
4.
5.
6. 7.
8.
9. 10.
11.12.
13.
14.
FLOOR PLAN LEGEND
INDICATES PARTITION WITH SOUNDATTENUATION INSULATION. REFER TOTHE WALL PARTITION SCHEDULE
2 HR SHAFT WALL UNLESS NOTED OTHERWISE , SEE G SERIES SHEETS FOR WALL TYPESCHEDULE, RATED ASSEMBLIES AND A600 SERIES SHEETS FOR INTERIOR DETAILS. SHAFTWALL ASSEMBLY TO BE CONTINOUS AND THROUGH THE ROOF. WALL ASSEMBLY TO GOTHROUGH THE PODIUM EXCEPT AT SUPPLY AND RETURN AIR FOR RESIDENTIAL CORRIDORS.PROVIDE A HORIZONTAL SHAFT WALL ASSEMBLY AT THE BOTTOM OF THE SHAFT. SEE THEGENERAL NOTES ON THIS SHEET FOR ACCESS PANEL REQUIREMENTS AT SHAFT ENCLOSURE.SEE THE SHAFT ASSEMBLY VERTICAL DETAILS.
PLAN ELEVATION
MAIL BOX
PARCEL BOX
LINE INDICATES ORIENTATION OF KEYHOLE FOR FOR ANSICOMPLIANCE
SEMI-RECESSED FIRE EXTINGUISHER CABINET. INSTALL FIREEXTINGUISHER SO THAT THE INTEGRITY OF RATED WALL ISMAINTANED. CONTINUE TYPE X GYP BOARD ASSEMBLYBEHIND FIRE EXTINGUISHER CABINET. UNIT SHALL NOTENCROACH MORE THAN 4" INTO THE PATH OF EGRESS.
HEARING IMPAIRED UNIT, SEE MEP INFORMATION FORADDITIONAL REQUIREMENTS. SEE CODE FLOOR PLANS FORLOCATIONS
TYPE A FULLY ACCESSIBLE UNIT. SEE CODE FLOOR PLANSFOR LOCATIONS
REQUIRED 30"X48" WHEELCHAIR CLEARANCE. 48" SHALL BECENTERED AT SINKS AND KITCHEN RANGE
2'-10" MAXIMUM HEIGHT TO THE TOP OF THE KITCHEN ORBATHROOM SINK RIM. TYP. AT PUBLIC AREAS & TYPE AANSI UNITS
*
ELECTRIC FIRE PLACE AND GYPSUM BOARD SURROUND TYP.AT ALL 1, 2 AND 3-BEDROOM PENTHOUSE UNITS U.N.O.
BALCONY
EXT. WALL
UNIT INTERIOR
VTAC FLOOR PLAN DIAGRAM
1 HR RATED WALL
2 HR RATED WALL
1/2 HR RATED WALL
PORTABLE FIRE EXTINGUISHER
TYPICAL ACCESS PANEL LOCATION FORMECHANICAL UNIT. ACCESS PANEL TOBE PAINTED TO MATCH ADJACENT WALL
MECHANICALLOUVER. PAINTTO MATCHEXT. FINISH.
(VTAC UNIT TO BE INSTALLED AT TYPICALRESIDENTIAL LEVELS. AT PENTHOUSELEVEL ONLY, LOCATE CLOSET AND DOORIN LIEU OF VTAC UNIT)
11
H
J
10 3
A501
1b
A501
SLOPE
SLO
PE
SLOPE
SLO
PE
J.2
PEDESTRIANTRAFFIC COATING
J.1
H.8
A5601
Sim
A5602
Sim
EQ EQ EQ EQ EQ EQ
EQE
QE
Q
DOOR - SEE DOORSCHEDULE
A.D.A. THRESHOLD
SEE STOREFRONT ELEVATIONS
8"
SEE STOREFRONT ELEVATIONS
8"
SEE STOREFRONT ELEVATIONS
SE
E S
TO
RE
FR
ON
T E
LE
VA
TIO
NS
PROPERTY LINE
FLOOR DRAIN -SEE PLUMBING
GUARDRAIL
GUARDRAIL
STRUCTURALCOLUMN SEESTRUCT.
A5603
Sim
J.
CURTIS
MOODY
7066
© 2
015 M
oody/
Nola
n Inc.
for
Dwg. Coord.: Tech. Coord.:
PR
INT
DA
TE
:
FIL
E IN
FO
:
Phone: (614) 461-4664Fax: (614) 280-8881
www.moodynolan.com
300 Spruce StreetSuite 300Columbus, Ohio 43215 CURTIS J. MOODY, LIC. #7066
EXP. DATE: 12/31/2015
B2
KEY PLAN
CITY OF DUBLIN APPROVAL
MOONEY STREET
BA
NK
ER
DR
IVE
BR
IDG
E P
AR
K A
VE
NU
E
M OONEY STREET
LONGSHORE STREET
L ONGSHORE STREET
3/2
3/2
016 1
0:4
2:4
6 A
M
C:\$$Loc a
l Revi
t P
roj e
cts\
2016 P
roje
c ts\
14145 -
Bridge P
ark
- B
LD
G B
2 -
AR
CH
_G
Briya
.rvt
A121
14145
08-03-2015
LEVEL 2 - FLOORPLAN
BRIDGE PARK BUILDING B2
CRAWFORD HOYINGdevelopment
Author Checker
GMP/PERMITSET
6580 RIVERSIDE DR. DUBLIN, OHIO 43017
PLAN 1/8" = 1'-0"
LEVEL 2 - FLOOR PLAN1
PLAN 3/8" = 1'-0"
LEVEL 2 - ELEVATED PATIO2
FD
COLUMN WRAP
FD
# DATE CHANGE DESCRIPTION
Approved forConstructionBPS.15-22369.COM.COM_EPR.1883.3621106/08/16
UPUP
F.E
.C.
F.E.C.
W D
RE
F.
W /D
W/H
STOVE REF.
MICRO
W/D
DW
STOVE REF.MICRO
W/H
W/H
D
W
REF.
DW MICRO
DW
W/D
W/ H
ST
OV
ER
EF
.
MIC
RO
W/D
W/H
ST
OV
ER
EF
.
MIC
RO
DW
W/H W/D
DW
STOVEREF. MICRO
W/ D
W/H
ST
OV
ER
EF
.M
ICR
O
W/D
W/H
ST
OV
ER
EF
.M
ICR
O
DW
DW
MIC
RO
W/H
W/H W/D
STOVEREF. MICRO
DW
DW
DW
F.E.C.
F.E.
A302
2
A301
2
11
H
B
G
F
D
A.1
2
A401
2
A401
1
A401
1
A401
1BR
308
1 BR
307
1 BR
309
2 BR
301
1 BR
303
2
A301
3
A302
1
STAIR 1
S1-300
A302
3
A302
4
STAIR 2
S2-3002 BR
305
2 BR
312
WS
WS
AW4
AW10
AW10
AW4AW4
AW10
AW7AW5
AW10
AW4
AW10
AW9
AW8
TRASH
TR300TR300
E300
WC
WC
WC
WD
WD
WD
WD
WD
WC
WC
WC
WS
WC
WD
WE
1
A502
2
A504
2
A502
3
A505
1
A555
RD
RD
A6011
6'-8
5/8
"
13'-2 1
/8"
4'-0"
6'-4
5/8
"
6'-8"
4'-5"
6'-8"
2'-4"
3'-4"
4'-8"
10'-0"
4'-7"
3'-4"
6'-0"
6'-8"
4'-8"
4'-0" 6'-8" 4'-0" 4'-0" 2'-8" 4'-0" 4'-0" 6'-8" 4'-0"
A301
5
A6101
1
A5032
A503
3
A503
3
A504
1
A504
A301
6
A301
4
1
A505
2
A505
ALUMINUM GUARDRAILCOORDINATE W/ ROOFGARDEN PLANS
2
A501
1
A501
WD
A6111
ELECT.
E300
6'-8
"9
'- 3 5
/8"
4' -8
"
3'- 1
0 3
/8"
3' -4
"6'-0
"6'-8
" 3' -6
"
4'-8
"9'-4
"6'-8
"
C300
MAINT. RM
M300
CORRIDOR
C300
STORAGE
S300
M300
S300
LOBBY
L300
1 3 4
A
J
5
7
6 8
12
9
10
C
E
1 BR
310
2 BR
300
1 BR
311
A6513
A6523
A653 2
3
A501
A1312
A1613
A191 2
2.2
J.2
F.2
A151 2
4
A552
AW1AW21
AW10
AW10
AW10
AW9
AW10 AW3 AW3 AW10
AW9
AW9
AW11
AW7
AW2 AW2 AW2
AW2
AW2
AW2
AW7
RAM
P U
P
J.1
F.3
H.8
0.9
AW10
AW4
AW13 AW13
AW14
AW14
AW9
AW9
AW12
AW12 AW15
AW15
AW3
10'-7
3/4
"
3'-4
7/1
6"
12
'- 0"
+EL . 835'-11"
+EL.835'-4"
64'-8
"
40'-0"
3'-3" 2'-4"
3'-3
"
2'-0
"
4'-8" 6'-0" 5'-4" 4'-0" 3'-4" 3'-8"
23'-4"
1 1'-4"2'-0"6'-8"
4'-8"6'-0"
6'-0"3'-4"3'-4"10'-0"
5'-6"6'-8"
5'-10"10'-0"
3'-0"6'-8"
5'-8"
11'-3 1/2"
11"
11'-4"
2'-0 1/2"
2'-1 1/4"
2'-0" 6'-0"
3'-1 1/2"
2'-4" 6'-8" 2'-4" 3'-4" 1'-4" 3'-4" 1'-4" 3'-4" 3'-4" 3'-0"
4'-8"
3'-4"
1'-4"
3'-4"
1'-4"
3'-4"
8'-9 1
/2"
6'-0"
3'-4"
3'-4"
3'-3"
10'-0"
3'-3"
S2-3
00
WS
5'-0"
12'-6 1
/2"
5'-0"
27'-1"
2'-0 1
/2"
3'-3 1
/2"
WC
28'-5 7/8" 8" 5'-6" 8"
5'-4"
19'-1 5
/8"
6'-4"
11'-7 3
/4"
6"
WD WS
WS
WS
24'-3 13/16"4'-1 1/16" 5'-0"
20'-9 11/16"5'-0"
14'-9 1/4"10'-0"
12'-2"6'-1"
WST
WST
8"4'-7 5/8" 10'-0 3/4"
23'-11 3/4"5'-0"
25'-0 1/4"13'-1 7/16" 5'-3 7/8" 11'-10 3/4"
5'-4 1/4" 2'-1 11/16" 15'-5 7/8"5'-0"
WE
25'-5
13/1
6"
8"
5'-6
" 8"
WE
WE
INSTALL ACCESSPANEL @ ALLLEVELS
INSTALL ACCESSPANEL @ ALLLEVELS
INSTALL ACCESSPANEL @ ALLLEVELS
INSTALL ACCESSPANEL @ ALLLEVELS
6'-4 1
/4"
8'-5
1/4
"
WC
WE
1 1'-4"3'-7 7/8"
6'-8"2'-0"2'-8"6'-4"
6'-0"4'-8"
10'-0"6'-0"
6'-8"6'-0"
10'-0"2'-4"3'-4"1'-4"3'-4"1'-4"3'-4"
WS WST
WST
WD
WD 12A
WC
WC
WS
WC
WS
25'-7" 13'-0" 4'-2 3/4" 23'-4"
27'-1 3
/4"
14'-10 5
/16"
31'-7 1
/4"
7'-1 7
/16"
29'-2 1
/2"
15'-2 5
/16"
26'-2"
19'-8"
7'-9 1/16"
22'-2 15/16"
31'-5
1/8
"
26'-4
3/8
"
32'-4"
9'-10 7/16"
20'-1 9/16"
8'-10 1/8"
21'-1 7/8"
7'-9 13/16"
ROOF AMENITYGARDEN; REFER TOLANDSCAPE PLANS
AW21
1
WE
C301
C302
S1-3
01
EXIT PASSAGE
C301
CORRIDOR
C3023'-4"
3'-6"
4'-7 1
/2"
6'-0"
11
13
13
13
GENERAL NOTES - FLOOR PLAN1. ALL DIMENSIONS ARE TO FACE OF WALL (UNLESS NOTED
OTHERWISE).SEE STRUCTURAL DRAWINGS FOR LOCATIONS OF ALL STEELREINFORCING IN WALL & FLOOR CONSTRUCTION.SEE FINISH SCHEDULE FOR ADDITIONAL INFORMATION OF LOCATIONSAND TYPES OF FINISH MATERIALS.SEE ELEVATIONS AND STRUCTURAL DRAWINGS FOR LOCATIONS OFEXPANSION & CONTROL JOINTS. CONTRACTOR SHALL PROVIDEADDITIONAL INTERIOR CONTROL JOINTS AS REQUIRED TO COMPLYWITH MAXIMUM SPACING REQUIREMENTS IN SPECIFICATIONS ANDNATIONAL MASONRY INSTITUTE. SEE DETAILS ON AXXX.
MECHANICAL & ELECTRICAL EQUIPMENT SHALL BE ON HOUSEKEEPINGPADS. PADS ARE TO PROVIDED BY THE TRADE SUPPLYING THEEQUIPMENT. SEE MECHANICAL AND ELECTRICAL DRAWINGS FORADDITIONAL INFORMATION. WORK TO BE COORDINATED THROUGHTHE GENERAL TRADES CONTRACTOR. PADS 4" MIN. 4" THICK W/W.W.F., UNLESS NOTED OTHERWISE).SEE G SERIES SHEETS FOR WALL TYPE CONSTRUCTION.PROVIDE AN 24" X 36" FIRE RATED ACCESS PANEL PER FLOOR AT ALLKITCHEN GREASE SHAFT LOCATIONS AND EVERY OTHER FLOOR FORALL OTHER SHAFT LOCATIONS. ACCESS PANELS TO FACE THE PUBLICCORRIDOR SIDE. COORDINATE MOUNTING HEIGHT WITH ARCHITECT INTHE FIELD.DO NOT RUN PIPELINE, CONDUITS OR ANY DEVICES INTO THE SHAFTASSEMBLIES. SHAFT ASSEMBLIES TO REMAIN FOR THE SOLEPURPOSE OF THE MECHANICAL DUCTS.ELEVATION 810.00 EQUALS 100'-0"INSTALL FIRE EXTINGUISHER SO THE INTEGRITY OF THE RATED WALL ISMAINTAINED. CONTINUE THE TYPE X GYPSUM BOARD ASSEMBLYBEHIND THE FIRE EXTINGUISHER CABINET.SEE A600 SERIES SHEETS FOR UNIT LAYOUT INFORMATIONALL WOOD SILL PLATES IN WALLS AT PODIUM LEVEL TO BE PRESSURETREATED.EXTERIOR BEARING WALLS TO BE 1 HOUR RATED PER U.L.# U364.REFER TO STRUCTURAL SHEETS FOR BEARING WALL CONDITIONS.COORDINATE SHAFT WALL ALIGNMENT WITH ARCHITECT TO MAINTAINREQUIRED RATING IN ADJACENT WALLS.
2.
3.
4.
5.
6. 7.
8.
9. 10.
11.12.
13.
14.
FLOOR PLAN LEGEND
INDICATES PARTITION WITH SOUNDATTENUATION INSULATION. REFER TOTHE WALL PARTITION SCHEDULE
2 HR SHAFT WALL UNLESS NOTED OTHERWISE , SEE G SERIES SHEETS FOR WALL TYPESCHEDULE, RATED ASSEMBLIES AND A600 SERIES SHEETS FOR INTERIOR DETAILS. SHAFTWALL ASSEMBLY TO BE CONTINOUS AND THROUGH THE ROOF. WALL ASSEMBLY TO GOTHROUGH THE PODIUM EXCEPT AT SUPPLY AND RETURN AIR FOR RESIDENTIAL CORRIDORS.PROVIDE A HORIZONTAL SHAFT WALL ASSEMBLY AT THE BOTTOM OF THE SHAFT. SEE THEGENERAL NOTES ON THIS SHEET FOR ACCESS PANEL REQUIREMENTS AT SHAFT ENCLOSURE.SEE THE SHAFT ASSEMBLY VERTICAL DETAILS.
PLAN ELEVATION
MAIL BOX
PARCEL BOX
LINE INDICATES ORIENTATION OF KEYHOLE FOR FOR ANSICOMPLIANCE
SEMI-RECESSED FIRE EXTINGUISHER CABINET. INSTALL FIREEXTINGUISHER SO THAT THE INTEGRITY OF RATED WALL ISMAINTANED. CONTINUE TYPE X GYP BOARD ASSEMBLYBEHIND FIRE EXTINGUISHER CABINET. UNIT SHALL NOTENCROACH MORE THAN 4" INTO THE PATH OF EGRESS.
HEARING IMPAIRED UNIT, SEE MEP INFORMATION FORADDITIONAL REQUIREMENTS. SEE CODE FLOOR PLANS FORLOCATIONS
TYPE A FULLY ACCESSIBLE UNIT. SEE CODE FLOOR PLANSFOR LOCATIONS
REQUIRED 30"X48" WHEELCHAIR CLEARANCE. 48" SHALL BECENTERED AT SINKS AND KITCHEN RANGE
2'-10" MAXIMUM HEIGHT TO THE TOP OF THE KITCHEN ORBATHROOM SINK RIM. TYP. AT PUBLIC AREAS & TYPE AANSI UNITS
*
ELECTRIC FIRE PLACE AND GYPSUM BOARD SURROUND TYP.AT ALL 1, 2 AND 3-BEDROOM PENTHOUSE UNITS U.N.O.
BALCONY
EXT. WALL
UNIT INTERIOR
VTAC FLOOR PLAN DIAGRAM
1 HR RATED WALL
2 HR RATED WALL
1 HR RATED WALL
PORTABLE FIRE EXTINGUISHER
TYPICAL ACCESS PANEL LOCATION FORMECHANICAL UNIT. ACCESS PANEL TOBE PAINTED TO MATCH ADJACENT WALL
MECHANICALLOUVER. PAINTTO MATCHEXT. FINISH.
(VTAC UNIT TO BE INSTALLED AT TYPICALRESIDENTIAL LEVELS. AT PENTHOUSELEVEL ONLY, LOCATE CLOSET AND DOORIN LIEU OF VTAC UNIT)
7
B
1
A501
SLOPE
SLO
PE
SLOPE
CONCRETE TOPPING W/WATER REPELLANT
EQEQ EQ
PROPERTY LINE
9 1/4" 10'-0" 9 1/4"
6'-10 3
/4"
CONTINUOUS AIR BARRIER(WHERE INDICATED WITH ADASHED LINE)
2" AIR SPACE
2x6 WOOD STUDS
5/8" INTERIORWALL BOARD
5/8" EXTERIOR GRADE WALLBOARD.
BRICK VENEER
BATT INSULATION
BRICK TIE
LIVING UNITDEMISING WALL -SEE PLAN
AIR BARRIER SHOWN DASHED
2x6 WOOD STUDS
5/8" INTERIOR WALL BOARD WHERESHOWN.
5/8" EXTERIOR GRADE WALL BOARD.
5/16" FIBER CEMENT PANEL ON VERTICALFURRING STRIPS (SEE DETAILS)
BATT INSULATION
WINDOW REFER TOELEVATIONS / WINDOWELEVATIONS
INTERIORPARTITION - SEEPLAN
PROVIDEFURRING ASREQUIRED TOALIGN INTERIORPARTITION.
DOOR - SEE DOORSCHEDULE
A.D.A. THRESHOLD
SEALANT & BACKER ROD
GUARDRAIL
1'-3 5
/8"
8".
B
1
A501
SLO
PE
SLOPESLOPE
CONCRETE TOPPING W/WATER REPELLANT
EQ EQ EQ
1'-0"1'-0"
6'-10 3
/4"
PROPERTY LINE
CONTINUOUS AIR BARRIER(WHERE INDICATED WITHA DASHED LINE)
2x6 WOOD STUDS
5/8" INTERIORWALL BOARD
5/8" EXTERIORGRADE WALL BOARD.
BATT INSULATION
LIVING UNITDEMISING WALL -SEE PLAN
AIR BARRIER SHOWN DASHED
2x6 WOOD STUDS
5/8" INTERIOR WALL BOARD WHERESHOWN.
5/8" EXTERIOR GRADE WALL BOARD.
5/16" FIBER CEMENT PANEL ON VERTICALFURRING STRIPS (SEE DETAILS)
BATT INSULATION
WINDOW REFER TOELEVATIONS / WINDOWELEVATIONS
INTERIORPARTITION - SEEPLAN
PROVIDEFURRING ASREQUIRED TOALIGN INTERIORPARTITION.
DOOR - SEE DOORSCHEDULE
A.D.A. THRESHOLD
GUARDRAIL
J.
CURTIS
MOODY
7066
© 2
015 M
oody/
Nola
n Inc.
for
Dwg. Coord.: Tech. Coord.:
PR
INT
DA
TE
:
FIL
E IN
FO
:
Phone: (614) 461-4664Fax: (614) 280-8881
www.moodynolan.com
300 Spruce StreetSuite 300Columbus, Ohio 43215 CURTIS J. MOODY, LIC. #7066
EXP. DATE: 12/31/2015
B2
KEY PLAN
CITY OF DUBLIN APPROVAL
MOONEY STREET
BA
NK
ER
DR
IVE
BR
IDG
E P
AR
K A
VE
NU
E
M OONEY STREET
LONGSHORE STREET
L ONGSHORE STREET
1/5
/ 2017 8
:09:3
0 A
M
C:\$$Loc a
l Revi
t P
roj e
cts\
2016 P
roje
c ts\
14145 -
Bridge P
ark
- B
LD
G B
2 -
AR
CH
_G
Briya
.rvt
A131
14145
08-03-2015
LEVEL 3 - FLOORPLAN
BRIDGE PARK BUILDING B2
Author Checker
GMP/PERMITSET
6580 RIVERSIDE DR. DUBLIN, OHIO 43017
PLAN 1/8" = 1'-0"
LEVEL 3 - FLOOR PLAN1
PLAN 1" = 1'-0"
LEVEL 3, 4 & 5 - TYP. BALCONY 2 PLAN 1" = 1'-0"
LEVEL 6 - TYP. BALCONY3
# DATE CHANGE DESCRIPTION
3 2-08-16 BULLETIN #2
5 3-23-16 BULLETIN #4
7 5-27-16 BULLETIN 7
11 Date 11 BULLETIN #13
13 12-22-16 BULLETIN #17
3
5
5
5
Approved forConstructionBPS.15-22369.COM.COM_EPR.1883.3621102/24/17
DW
UP
UP
UP
F. E
. C.
F.E.C.
W/ D
W/H
ST
OV
ER
EF
.M
ICR
O
STOVEREF. MICRO
W/D
W/H
ST
OV
ER
EF
.
MIC
RO
W/DW/H
ST
OV
ER
EF
.
MIC
RO
W/ D
W/H
STOVE REF.
MICRO
DW
ST
OV
E
R
EF
.
MIC
RO
DW
DW
DW
W/D
W/H
ST
OV
ER
EF
.
MIC
RO
DW
W/HW/D
DW
STOVEREF. MICRO
W/D
W/H
ST
OV
ER
EF
.M
ICR
O
DW
W/D
W/H
ST
OV
ER
EF
.M
ICR
O
DW
W /DW/H
W/HW/D
DW
STOVE REF.MICRO
W/HW/D
DW
DW
F.E.C.
F.E.
A302
2
A301
2
11
H
B
G
F
D
A.1
2
A401
2
A401
1
A401
1
A401
A301
1
2
A301
3
A302
1
A302
3
A302
4
1
A502
2
A504
2
A502
3
A505
STAIR 2
S2-400
1 BR
403
2 BR
401
TRASH
TR400
1 BR
408
1 BR
407
1 BR
409
2 BR
412
1 BR
410
A301
5
WD
WC
WC
WD
WC
WC
WC
WCWC
WC
WD
WD
WD
WD
WD
1
A503
2
A503
3
A503
1
A504
A301
6
A301
4
1
A505
2
A505
2
A5011
A501
AW4
AW10
AW4AW4
AW7AW5
AW10
AW10
AW9
AW8
AW7
AW11
AW10
AW4
AW10
AW9
AW10
AW4
BRIDGE
VESTIBULE
L400
STAIR 1
S1-400CORRIDOR
C400
L400
STORAGE
S400
ELECT
E400E400
LOBBY
L401
L400A
1 3 4
A
J
5
7
6 8
12
9
10
C
E
5
A660
A6532
A6514
A6524
2.2
J.2
F.2
S2-4
00
2 BR
405
2 BR
400
1 BR
411
J.1
F.3
H.8
0.9
K
7'-0"
18'-8"
AW4AW4 AW4
AW3
AW10
AW4
AW9
AW10
AW1AW21
AW10
AW10
AW9
AW7
AW4
AW4
AW4
AW10
AW9
AW9
AW3 AW3
AW14
AW13
AW12
AW15
AW12
AW15
S400
TR400
1
S1-4
01
5
5'-2" 5'-6" 5'-4" 4'-0" 3'-4"
11
13
FLOOR PLAN LEGEND
INDICATES PARTITION WITH SOUNDATTENUATION INSULATION. REFER TOTHE WALL PARTITION SCHEDULE
2 HR SHAFT WALL UNLESS NOTED OTHERWISE , SEE G SERIES SHEETS FOR WALL TYPESCHEDULE, RATED ASSEMBLIES AND A600 SERIES SHEETS FOR INTERIOR DETAILS. SHAFTWALL ASSEMBLY TO BE CONTINOUS AND THROUGH THE ROOF. WALL ASSEMBLY TO GOTHROUGH THE PODIUM EXCEPT AT SUPPLY AND RETURN AIR FOR RESIDENTIAL CORRIDORS.PROVIDE A HORIZONTAL SHAFT WALL ASSEMBLY AT THE BOTTOM OF THE SHAFT. SEE THEGENERAL NOTES ON THIS SHEET FOR ACCESS PANEL REQUIREMENTS AT SHAFT ENCLOSURE.SEE THE SHAFT ASSEMBLY VERTICAL DETAILS.
PLAN ELEVATION
MAIL BOX
PARCEL BOX
LINE INDICATES ORIENTATION OF KEYHOLE FOR FOR ANSICOMPLIANCE
SEMI-RECESSED FIRE EXTINGUISHER CABINET. INSTALL FIREEXTINGUISHER SO THAT THE INTEGRITY OF RATED WALL ISMAINTANED. CONTINUE TYPE X GYP BOARD ASSEMBLYBEHIND FIRE EXTINGUISHER CABINET. UNIT SHALL NOTENCROACH MORE THAN 4" INTO THE PATH OF EGRESS.
HEARING IMPAIRED UNIT, SEE MEP INFORMATION FORADDITIONAL REQUIREMENTS. SEE CODE FLOOR PLANS FORLOCATIONS
TYPE A FULLY ACCESSIBLE UNIT. SEE CODE FLOOR PLANSFOR LOCATIONS
REQUIRED 30"X48" WHEELCHAIR CLEARANCE. 48" SHALL BECENTERED AT SINKS AND KITCHEN RANGE
2'-10" MAXIMUM HEIGHT TO THE TOP OF THE KITCHEN ORBATHROOM SINK RIM. TYP. AT PUBLIC AREAS & TYPE AANSI UNITS
*
ELECTRIC FIRE PLACE AND GYPSUM BOARD SURROUND TYP.AT ALL 1, 2 AND 3-BEDROOM PENTHOUSE UNITS U.N.O.
BALCONY
EXT. WALL
UNIT INTERIOR
VTAC FLOOR PLAN DIAGRAM
1 HR RATED WALL
2 HR RATED WALL
1 HR RATED WALL
PORTABLE FIRE EXTINGUISHER
TYPICAL ACCESS PANEL LOCATION FORMECHANICAL UNIT. ACCESS PANEL TOBE PAINTED TO MATCH ADJACENT WALL
MECHANICALLOUVER. PAINTTO MATCHEXT. FINISH.
(VTAC UNIT TO BE INSTALLED AT TYPICALRESIDENTIAL LEVELS. AT PENTHOUSELEVEL ONLY, LOCATE CLOSET AND DOORIN LIEU OF VTAC UNIT)
7
GENERAL NOTES - FLOOR PLAN1. ALL DIMENSIONS ARE TO FACE OF WALL (UNLESS NOTED
OTHERWISE).SEE STRUCTURAL DRAWINGS FOR LOCATIONS OF ALL STEELREINFORCING IN WALL & FLOOR CONSTRUCTION.SEE FINISH SCHEDULE FOR ADDITIONAL INFORMATION OF LOCATIONSAND TYPES OF FINISH MATERIALS.SEE ELEVATIONS AND STRUCTURAL DRAWINGS FOR LOCATIONS OFEXPANSION & CONTROL JOINTS. CONTRACTOR SHALL PROVIDEADDITIONAL INTERIOR CONTROL JOINTS AS REQUIRED TO COMPLYWITH MAXIMUM SPACING REQUIREMENTS IN SPECIFICATIONS ANDNATIONAL MASONRY INSTITUTE. SEE DETAILS ON AXXX.
MECHANICAL & ELECTRICAL EQUIPMENT SHALL BE ON HOUSEKEEPINGPADS. PADS ARE TO PROVIDED BY THE TRADE SUPPLYING THEEQUIPMENT. SEE MECHANICAL AND ELECTRICAL DRAWINGS FORADDITIONAL INFORMATION. WORK TO BE COORDINATED THROUGHTHE GENERAL TRADES CONTRACTOR. PADS 4" MIN. 4" THICK W/W.W.F., UNLESS NOTED OTHERWISE).SEE G SERIES SHEETS FOR WALL TYPE CONSTRUCTION.PROVIDE AN 24" X 36" FIRE RATED ACCESS PANEL PER FLOOR AT ALLKITCHEN GREASE SHAFT LOCATIONS AND EVERY OTHER FLOOR FORALL OTHER SHAFT LOCATIONS. ACCESS PANELS TO FACE THE PUBLICCORRIDOR SIDE. COORDINATE MOUNTING HEIGHT WITH ARCHITECT INTHE FIELD.DO NOT RUN PIPELINE, CONDUITS OR ANY DEVICES INTO THE SHAFTASSEMBLIES. SHAFT ASSEMBLIES TO REMAIN FOR THE SOLEPURPOSE OF THE MECHANICAL DUCTS.ELEVATION 810.00 EQUALS 100'-0"INSTALL FIRE EXTINGUISHER SO THE INTEGRITY OF THE RATED WALL ISMAINTAINED. CONTINUE THE TYPE X GYPSUM BOARD ASSEMBLYBEHIND THE FIRE EXTINGUISHER CABINET.SEE A600 SERIES SHEETS FOR UNIT LAYOUT INFORMATIONALL WOOD SILL PLATES IN WALLS AT PODIUM LEVEL TO BE PRESSURETREATED.EXTERIOR BEARING WALLS TO BE 1 HOUR RATED PER U.L.# U364.REFER TO STRUCTURAL SHEETS FOR BEARING WALL CONDITIONS.COORDINATE SHAFT WALL ALIGNMENT WITH ARCHITECT TO MAINTAINREQUIRED RATING IN ADJACENT WALLS.
2.
3.
4.
5.
6. 7.
8.
9. 10.
11.12.
13.
14.
J.
CURTIS
MOODY
7066
© 2
015 M
oody/
Nola
n Inc.
for
Dwg. Coord.: Tech. Coord.:
PR
INT
DA
TE
:
FIL
E IN
FO
:
Phone: (614) 461-4664Fax: (614) 280-8881
www.moodynolan.com
300 Spruce Street
Suite 300
Columbus, Ohio 43215 CURTIS J. MOODY, LIC. #7066EXP. DATE: 12/31/2015
B2
KEY PLAN
CITY OF DUBLIN APPROVAL
MOONEY STREET
BA
NK
ER
DR
IVE
BR
IDG
E P
AR
K A
VE
NU
E
M OONEY STREET
LONGSHORE STREET
L ONGSHORE STREET
1/5
/ 2017 8
:09:4
3 A
M
C:\$$Loc a
l Revi
t P
roj e
cts\
2016 P
roje
c ts\
14145 -
Bridge P
ark
- B
LD
G B
2 -
AR
CH
_G
Briya
.rvt
A141
14145
08-03-2015
LEVEL 4 - FLOORPLAN
BRIDGE PARK BUILDING B2
Author Checker
GMP/PERMITSET
6580 RIVERSIDE DR. DUBLIN, OHIO 43017
PLAN 1/8" = 1'-0"
LEVEL 4 - FLOOR PLAN1
REFER TO A660 FOR BRIDGEPLANS AND DETAILS
BUILDING B3
BUILDING B4
REFER TO SHEET A131 FOR DIMENSIONSAND WALL TYPES UNLESS NOTED ON PLAN
# DATE CHANGE DESCRIPTION
1 8-21-15 ADDENDUM #1
5 3-23-16 BULLETIN #4
7 5-27-16 BULLETIN 7
11 Date 11 BULLETIN #13
13 12-22-16 BULLETIN #17
5
Approved forConstructionBPS.15-22369.COM.COM_EPR.1883.3621102/24/17
DW
F.E.C.
F.E.C.
W /DW
/H
ST
OV
ER
EF
.M
ICR
O
STOVEREF.MICRO
W/D
W/H
ST
OV
ER
EF
.
MI C
RO
W/DW/H
ST
OV
ER
EF
.
MIC
RO
W /D
W/H
S TOVE REF.
MICRO
W/HW/D
DW
STOVE REF. MICRO
DW
ST
OV
E
R
EF
.M
ICR
O
DW
DW
DW
W/D
W/ H
ST
OV
ER
EF
.
MIC
RO
DW
W/HW/D
DW
STOVEREF.MICRO
W/D
W/H
ST
OV
ER
EF
.M
ICR
O
DW
W /DW/H
W/HW/D
DW
DW
F.E.C.
F.E.
A302
2
A301
2
11
H
B
G
F
D
A.1
2
A401
2
A401
1
A401
1
A401
1 BR
507
1 BR
509
2 BR
512
1 BR
508
2 BR
501
STAIR 2
S2-500
2
A301
3
A302
1
STAIR 1
S1-500
A302
3
A302
4
6'-8"
5'-11 3
/4"
3'-4"
52'-4 1
/4"
6'-8"
30'-3 3
/8"
16'-4 3/4" 11'-1 1/2"
WS WS
AW10
AW4
AW10
AW4AW4
AW7AW10
AW10
AW4
AW10
AW7
AW8
WC
WC
WC
WC
WC
WC
WC
WD
WD
WDWD
WD
WD
1
A502
2
A504
2
A502
3
A505
A6021
A301
5
WC
WD
1
A5032
A503
3
A503
1
A504
A301
6
A301
4
1
A505
2
A505
2
A5011
A501
1 BR
510
1 BR
503
ELECT
E500
CORRIDOR
C500
STORAGE
S500
TRASH
TR500
LOBBY
L500
1 3 4
A
J
5
7 6 8 12
9
10
C
E
5
A660
A6532
A6513
A6524
2.2
J.2
F.2
A1513
16'-4 3/4" 1'-11 15/16" 6'-0"
3'-1 9/16"
2'-4" 6'-8" 2'-4" 3'-4" 1'-4" 3'-4" 1'-4" 3'-4"
14'-3 1/2"
S2-5
00
2 BR
500
2 BR
505
1 BR
511
J.1
F.3
H.8
0.9
K
AW9
AW9
AW10 AW3
AW10
AW4
AW7
AW4AW4 AW4
AW3
AW10
AW4
AW9
AW10
AW1AW21
AW10
AW10
AW5
AW3
AW9
AW4
AW4
AW4
AW11
AW9
AW9
AW6
AW14
AW14
AW13 AW13
AW12
AW12
AW15
AW15
3 '-7 7/8"6'-8"2'-0"2'-8"
6'-4"6'-0"
4'-8"10'-0"
10'-0"2'-4"3'-4"
1'-4"
3'-4"
1'-4"
3'-4"
11'-4"
5'-10 3/4"6'-8"
6'-1 1/4"
4'-8"
3'-4"
1'-4"
3'-4"
1'-4"
3'-4"
6'-0"
12'-1 1
/2"
TR500
S500
E500
1
A6031
A6061
S1-5
01
5'-2"
3'-6"
3'-4"
6'-5 3/8"
3'-2
1/2
"
3'-0"
5'-4
7/8
"
3'-11 1
/2"
11
13
GENERAL NOTES - FLOOR PLAN1. ALL DIMENSIONS ARE TO FACE OF WALL (UNLESS NOTED
OTHERWISE).SEE STRUCTURAL DRAWINGS FOR LOCATIONS OF ALL STEELREINFORCING IN WALL & FLOOR CONSTRUCTION.SEE FINISH SCHEDULE FOR ADDITIONAL INFORMATION OF LOCATIONSAND TYPES OF FINISH MATERIALS.SEE ELEVATIONS AND STRUCTURAL DRAWINGS FOR LOCATIONS OFEXPANSION & CONTROL JOINTS. CONTRACTOR SHALL PROVIDEADDITIONAL INTERIOR CONTROL JOINTS AS REQUIRED TO COMPLYWITH MAXIMUM SPACING REQUIREMENTS IN SPECIFICATIONS ANDNATIONAL MASONRY INSTITUTE. SEE DETAILS ON AXXX.
MECHANICAL & ELECTRICAL EQUIPMENT SHALL BE ON HOUSEKEEPINGPADS. PADS ARE TO PROVIDED BY THE TRADE SUPPLYING THEEQUIPMENT. SEE MECHANICAL AND ELECTRICAL DRAWINGS FORADDITIONAL INFORMATION. WORK TO BE COORDINATED THROUGHTHE GENERAL TRADES CONTRACTOR. PADS 4" MIN. 4" THICK W/W.W.F., UNLESS NOTED OTHERWISE).SEE G SERIES SHEETS FOR WALL TYPE CONSTRUCTION.PROVIDE AN 24" X 36" FIRE RATED ACCESS PANEL PER FLOOR AT ALLKITCHEN GREASE SHAFT LOCATIONS AND EVERY OTHER FLOOR FORALL OTHER SHAFT LOCATIONS. ACCESS PANELS TO FACE THE PUBLICCORRIDOR SIDE. COORDINATE MOUNTING HEIGHT WITH ARCHITECT INTHE FIELD.DO NOT RUN PIPELINE, CONDUITS OR ANY DEVICES INTO THE SHAFTASSEMBLIES. SHAFT ASSEMBLIES TO REMAIN FOR THE SOLEPURPOSE OF THE MECHANICAL DUCTS.ELEVATION 810.00 EQUALS 100'-0"INSTALL FIRE EXTINGUISHER SO THE INTEGRITY OF THE RATED WALL ISMAINTAINED. CONTINUE THE TYPE X GYPSUM BOARD ASSEMBLYBEHIND THE FIRE EXTINGUISHER CABINET.SEE A600 SERIES SHEETS FOR UNIT LAYOUT INFORMATIONALL WOOD SILL PLATES IN WALLS AT PODIUM LEVEL TO BE PRESSURETREATED.EXTERIOR BEARING WALLS TO BE 1 HOUR RATED PER U.L.# U364.REFER TO STRUCTURAL SHEETS FOR BEARING WALL CONDITIONS.COORDINATE SHAFT WALL ALIGNMENT WITH ARCHITECT TO MAINTAINREQUIRED RATING IN ADJACENT WALLS.
2.
3.
4.
5.
6. 7.
8.
9. 10.
11.12.
13.
14.
FLOOR PLAN LEGEND
INDICATES PARTITION WITH SOUNDATTENUATION INSULATION. REFER TOTHE WALL PARTITION SCHEDULE
2 HR SHAFT WALL UNLESS NOTED OTHERWISE , SEE G SERIES SHEETS FOR WALL TYPESCHEDULE, RATED ASSEMBLIES AND A600 SERIES SHEETS FOR INTERIOR DETAILS. SHAFTWALL ASSEMBLY TO BE CONTINOUS AND THROUGH THE ROOF. WALL ASSEMBLY TO GOTHROUGH THE PODIUM EXCEPT AT SUPPLY AND RETURN AIR FOR RESIDENTIAL CORRIDORS.PROVIDE A HORIZONTAL SHAFT WALL ASSEMBLY AT THE BOTTOM OF THE SHAFT. SEE THEGENERAL NOTES ON THIS SHEET FOR ACCESS PANEL REQUIREMENTS AT SHAFT ENCLOSURE.SEE THE SHAFT ASSEMBLY VERTICAL DETAILS.
PLAN ELEVATION
MAIL BOX
PARCEL BOX
LINE INDICATES ORIENTATION OF KEYHOLE FOR FOR ANSICOMPLIANCE
SEMI-RECESSED FIRE EXTINGUISHER CABINET. INSTALL FIREEXTINGUISHER SO THAT THE INTEGRITY OF RATED WALL ISMAINTANED. CONTINUE TYPE X GYP BOARD ASSEMBLYBEHIND FIRE EXTINGUISHER CABINET. UNIT SHALL NOTENCROACH MORE THAN 4" INTO THE PATH OF EGRESS.
HEARING IMPAIRED UNIT, SEE MEP INFORMATION FORADDITIONAL REQUIREMENTS. SEE CODE FLOOR PLANS FORLOCATIONS
TYPE A FULLY ACCESSIBLE UNIT. SEE CODE FLOOR PLANSFOR LOCATIONS
REQUIRED 30"X48" WHEELCHAIR CLEARANCE. 48" SHALL BECENTERED AT SINKS AND KITCHEN RANGE
2'-10" MAXIMUM HEIGHT TO THE TOP OF THE KITCHEN ORBATHROOM SINK RIM. TYP. AT PUBLIC AREAS & TYPE AANSI UNITS
*
ELECTRIC FIRE PLACE AND GYPSUM BOARD SURROUND TYP.AT ALL 1, 2 AND 3-BEDROOM PENTHOUSE UNITS U.N.O.
BALCONY
EXT. WALL
UNIT INTERIOR
VTAC FLOOR PLAN DIAGRAM
1 HR RATED WALL
2 HR RATED WALL
1 HR RATED WALL
PORTABLE FIRE EXTINGUISHER
TYPICAL ACCESS PANEL LOCATION FORMECHANICAL UNIT. ACCESS PANEL TOBE PAINTED TO MATCH ADJACENT WALL
MECHANICALLOUVER. PAINTTO MATCHEXT. FINISH.
(VTAC UNIT TO BE INSTALLED AT TYPICALRESIDENTIAL LEVELS. AT PENTHOUSELEVEL ONLY, LOCATE CLOSET AND DOORIN LIEU OF VTAC UNIT)
7
2
A5043 4
J
J.2
6'-8"
3 1/4"
SLOPE
SLO
PE
1/4
"/F
T.
M
IN
SLO
PE
SLOPE
PROPERTY LINE
AIR BARRIER SHOWN DASHED
2x6 WOOD STUDS
5/8" INTERIOR WALL BOARD WHERESHOWN.
5/8" EXTERIOR GRADE WALL BOARD.
5/16" FIBER CEMENT PANEL ON VERTICALFURRING STRIPS (SEE DETAILS)
BATT INSULATION
WINDOW REFER TOELEVATIONS / WINDOWELEVATIONS
DOOR - SEE DOORSCHEDULE
A.D.A. THRESHOLD
GUARDRAIL
2" AIR SPACE
BRICK TIE
BRICKVENEER
DRAIN - SEEPLUMBING
STONE CAPBELOW
CONCRETE TOPPING W/WATER REPELLANT
TY
P.
1'-4"
SEALANT & BACKER ROD
H
2
A504
3 4
J
J.2
SLOPE
SLO
PE
SLOPE
PROPERTY LINE
5"
9 1/4" 6'-8" 9 1/4"
CONCRETE TOPPING W/WATER REPELLANT
AIR BARRIER SHOWN DASHED
2x6 WOOD STUDS
5/8" INTERIOR WALL BOARD WHERESHOWN.
5/8" EXTERIOR GRADE WALL BOARD.
5/16" FIBER CEMENT PANEL ON VERTICALFURRING STRIPS (SEE DETAILS)
BATT INSULATION
WINDOW REFER TOELEVATIONS / WINDOWELEVATIONS
DOOR - SEE DOORSCHEDULE
A.D.A. THRESHOLD
GUARDRAIL
2" AIR SPACE
BRICK TIE
BRICKVENEER
TY
P.
1'-4"
SEALANT & BACKER ROD
J.
CURTIS
MOODY
7066
© 2
015 M
oody/
Nola
n Inc.
for
Dwg. Coord.: Tech. Coord.:
PR
INT
DA
TE
:
FIL
E IN
FO
:
Phone: (614) 461-4664Fax: (614) 280-8881
www.moodynolan.com
300 Spruce StreetSuite 300Columbus, Ohio 43215 CURTIS J. MOODY, LIC. #7066
EXP. DATE: 12/31/2015
B2
KEY PLAN
CITY OF DUBLIN APPROVAL
MOONEY STREET
BA
NK
ER
DR
IVE
BR
IDG
E P
AR
K A
VE
NU
E
M OONEY STREET
LONGSHORE STREET
L ONGSHORE STREET
1/5
/ 2017 8
:09:5
0 A
M
C:\$$Loc a
l Revi
t P
roj e
cts\
2016 P
roje
c ts\
14145 -
Bridge P
ark
- B
LD
G B
2 -
AR
CH
_G
Briya
.rvt
A151
14145
08-03-2015
LEVEL 5 - FLOORPLAN
BRIDGE PARK BUILDING B2
Author Checker
GMP/PERMITSET
6580 RIVERSIDE DR. DUBLIN, OHIO 43017
PLAN 1/8" = 1'-0"
LEVEL 5 - FLOOR PLAN1 PLAN 1" = 1'-0"
LEVEL 3 - WEST BALCONY2
PLAN 1" = 1'-0"
LEVEL 4 & 5 - WEST BALCONY3
REFER TO SHEET A131 FOR DIMENSIONSAND WALL TYPES UNLESS NOTED ON PLAN
# DATE CHANGE DESCRIPTION
1 8-21-15 ADDENDUM #1
5 3-23-16 BULLETIN #4
7 5-27-16 BULLETIN 7
11 Date 11 BULLETIN #13
13 12-22-16 BULLETIN #17
5 5
Approved forConstructionBPS.15-22369.COM.COM_EPR.1883.3621102/24/17
F .E.C
.
F.E.C.
W/D
W/H
ST
OV
ER
EF
.M
ICR
O
W/HW/D
STOVEREF. MICRO
W/D
W/H
ST
OV
ER
EF
.
MIC
RO
W/DW/H
ST
OV
ER
EF
.
MIC
RO
W /D
W/H
S TOVE REF.
MICRO
DW
DW
DW
W/D
W/H
ST
OV
ER
EF
.
MIC
RO
DW
W/D
W/ H
ST
OV
ER
EF
.M
ICR
O
DW
ST
OV
E
R
EF
.
MIC
RO
DW
W /D
W /H
W/H
DW
D
W
ST
OV
E
R
EF
.
MIC
RO
DW
DW
F.E.C.
F.E.
A302
2
A301
2
11
H
B
G
F
D
A.1
2
A401
2
A401
1
A401
1
A401
2 BR
605
1 BR
607
1 BR
609
2 BR
6121 BR
610
1 BR
608
1 BR
600
3 BR
603
2
A301
3
A302
1
STAIR 1
S1-600
A302
3
A302
4
TRASH
TR600
AW10
AW4
AW10
AW11
AW4AW4
AW10
AW7
AW10
AW4
AW10
AW7
AW9
WD
WD
WC WC
WC
WDWD
WC
WC
WC
WC
WD
ELECT
E600
WC
1
A502
2
A504
2
A502
3
A505A301
5
A6041
A6051
A6091
A6071
A6081
WD
1
A503 2
A503
3
A503
1
A504
GUARDRAIL REFER TO TYP.BALCONY
FLOOR DRAIN
A301
6
A301
4
1
A505
2
A505
2
A501
1
A501
CORRIDOR
C600
STAIR 2
S2-600
STORAGE
S600
LOBBY
L600
S600
1 3 4
A
J
5 7 6 8
12
9
10
C
EA6514
A6524
A6532
A1313
A1612
2.2
J.2
F.2
S2-6
00
J.1
F.3
H.8
0.9
AW14
AW14
AW13 AW13
AW9
AW10
AW4
AW3
AW10
AW4
AW9
AW10
AW10
AW10
AW1AW21
AW5
AW9
AW3 AW10 AW3
AW9
AW9
AW21
SF24
SF22
AW12 AW15
AW15
AW12
3'-2 1/4" 6'-9 1/2" 6'-2" 6'-9"
9'-1 1
/2"
12'-1 1
/4"
6'-0"
5'-4"
E600
TR600
ALTERNATINGSTAIR TO ROOF
3
AW7
A609A 1
A612 1
S1-6
01
11
13
GENERAL NOTES - FLOOR PLAN1. ALL DIMENSIONS ARE TO FACE OF WALL (UNLESS NOTED
OTHERWISE).SEE STRUCTURAL DRAWINGS FOR LOCATIONS OF ALL STEELREINFORCING IN WALL & FLOOR CONSTRUCTION.SEE FINISH SCHEDULE FOR ADDITIONAL INFORMATION OF LOCATIONSAND TYPES OF FINISH MATERIALS.SEE ELEVATIONS AND STRUCTURAL DRAWINGS FOR LOCATIONS OFEXPANSION & CONTROL JOINTS. CONTRACTOR SHALL PROVIDEADDITIONAL INTERIOR CONTROL JOINTS AS REQUIRED TO COMPLYWITH MAXIMUM SPACING REQUIREMENTS IN SPECIFICATIONS ANDNATIONAL MASONRY INSTITUTE. SEE DETAILS ON AXXX.
MECHANICAL & ELECTRICAL EQUIPMENT SHALL BE ON HOUSEKEEPINGPADS. PADS ARE TO PROVIDED BY THE TRADE SUPPLYING THEEQUIPMENT. SEE MECHANICAL AND ELECTRICAL DRAWINGS FORADDITIONAL INFORMATION. WORK TO BE COORDINATED THROUGHTHE GENERAL TRADES CONTRACTOR. PADS 4" MIN. 4" THICK W/W.W.F., UNLESS NOTED OTHERWISE).SEE G SERIES SHEETS FOR WALL TYPE CONSTRUCTION.PROVIDE AN 24" X 36" FIRE RATED ACCESS PANEL PER FLOOR AT ALLKITCHEN GREASE SHAFT LOCATIONS AND EVERY OTHER FLOOR FORALL OTHER SHAFT LOCATIONS. ACCESS PANELS TO FACE THE PUBLICCORRIDOR SIDE. COORDINATE MOUNTING HEIGHT WITH ARCHITECT INTHE FIELD.DO NOT RUN PIPELINE, CONDUITS OR ANY DEVICES INTO THE SHAFTASSEMBLIES. SHAFT ASSEMBLIES TO REMAIN FOR THE SOLEPURPOSE OF THE MECHANICAL DUCTS.ELEVATION 810.00 EQUALS 100'-0"INSTALL FIRE EXTINGUISHER SO THE INTEGRITY OF THE RATED WALL ISMAINTAINED. CONTINUE THE TYPE X GYPSUM BOARD ASSEMBLYBEHIND THE FIRE EXTINGUISHER CABINET.SEE A600 SERIES SHEETS FOR UNIT LAYOUT INFORMATIONALL WOOD SILL PLATES IN WALLS AT PODIUM LEVEL TO BE PRESSURETREATED.EXTERIOR BEARING WALLS TO BE 1 HOUR RATED PER U.L.# U364.REFER TO STRUCTURAL SHEETS FOR BEARING WALL CONDITIONS.COORDINATE SHAFT WALL ALIGNMENT WITH ARCHITECT TO MAINTAINREQUIRED RATING IN ADJACENT WALLS.
2.
3.
4.
5.
6. 7.
8.
9. 10.
11.12.
13.
14.
FLOOR PLAN LEGEND
INDICATES PARTITION WITH SOUNDATTENUATION INSULATION. REFER TOTHE WALL PARTITION SCHEDULE
2 HR SHAFT WALL UNLESS NOTED OTHERWISE , SEE G SERIES SHEETS FOR WALL TYPESCHEDULE, RATED ASSEMBLIES AND A600 SERIES SHEETS FOR INTERIOR DETAILS. SHAFTWALL ASSEMBLY TO BE CONTINOUS AND THROUGH THE ROOF. WALL ASSEMBLY TO GOTHROUGH THE PODIUM EXCEPT AT SUPPLY AND RETURN AIR FOR RESIDENTIAL CORRIDORS.PROVIDE A HORIZONTAL SHAFT WALL ASSEMBLY AT THE BOTTOM OF THE SHAFT. SEE THEGENERAL NOTES ON THIS SHEET FOR ACCESS PANEL REQUIREMENTS AT SHAFT ENCLOSURE.SEE THE SHAFT ASSEMBLY VERTICAL DETAILS.
PLAN ELEVATION
MAIL BOX
PARCEL BOX
LINE INDICATES ORIENTATION OF KEYHOLE FOR FOR ANSICOMPLIANCE
SEMI-RECESSED FIRE EXTINGUISHER CABINET. INSTALL FIREEXTINGUISHER SO THAT THE INTEGRITY OF RATED WALL ISMAINTANED. CONTINUE TYPE X GYP BOARD ASSEMBLYBEHIND FIRE EXTINGUISHER CABINET. UNIT SHALL NOTENCROACH MORE THAN 4" INTO THE PATH OF EGRESS.
HEARING IMPAIRED UNIT, SEE MEP INFORMATION FORADDITIONAL REQUIREMENTS. SEE CODE FLOOR PLANS FORLOCATIONS
TYPE A FULLY ACCESSIBLE UNIT. SEE CODE FLOOR PLANSFOR LOCATIONS
REQUIRED 30"X48" WHEELCHAIR CLEARANCE. 48" SHALL BECENTERED AT SINKS AND KITCHEN RANGE
2'-10" MAXIMUM HEIGHT TO THE TOP OF THE KITCHEN ORBATHROOM SINK RIM. TYP. AT PUBLIC AREAS & TYPE AANSI UNITS
*
ELECTRIC FIRE PLACE AND GYPSUM BOARD SURROUND TYP.AT ALL 1, 2 AND 3-BEDROOM PENTHOUSE UNITS U.N.O.
BALCONY
EXT. WALL
UNIT INTERIOR
VTAC FLOOR PLAN DIAGRAM
1 HR RATED WALL
2 HR RATED WALL
1 HR RATED WALL
PORTABLE FIRE EXTINGUISHER
TYPICAL ACCESS PANEL LOCATION FORMECHANICAL UNIT. ACCESS PANEL TOBE PAINTED TO MATCH ADJACENT WALL
MECHANICALLOUVER. PAINTTO MATCHEXT. FINISH.
(VTAC UNIT TO BE INSTALLED AT TYPICALRESIDENTIAL LEVELS. AT PENTHOUSELEVEL ONLY, LOCATE CLOSET AND DOORIN LIEU OF VTAC UNIT)
7
B
1
A502
12
SLO
PE
SLOPE
EQ EQ EQ
EQ
EQ
10"
2
A502
O/H
A1615
AIR BARRIER SHOWN DASHED
2x6 WOOD STUDS
5/8" INTERIOR WALL BOARDWHERE SHOWN.
5/8" EXTERIOR GRADE WALL BOARD.
5/16" FIBER CEMENT PANEL ON VERTICALFURRING STRIPS (SEE DETAILS)
BATT INSULATION
WINDOW REFER TOELEVATIONS / WINDOWELEVATIONS
GUARDRAIL
CONCRETE TOPPING W/WATER REPELLANT
DOOR - SEE DOORSCHEDULE
A.D.A. THRESHOLD
B
1
A502
12
SLOPE SLOPE
SLO
PE
SLO
PE
EQ EQ EQ
EQ
EQ
3'-3"
10"
2
A502
O/H
A1614
AIR BARRIER SHOWN DASHED
2x6 WOOD STUDS
5/8" INTERIOR WALL BOARDWHERE SHOWN.
5/8" EXTERIOR GRADE WALL BOARD.
BATT INSULATION
WINDOW REFER TOELEVATIONS / WINDOWELEVATIONS
GUARDRAIL
CONCRETE TOPPING W/WATER REPELLANT
DOOR - SEE DOORSCHEDULE
A.D.A. THRESHOLD DRAIN & DRAINAGE PATTERN SHOWN @ LEVEL 3ONLY - REFER TO LEVEL 6 DRAINAGE & SECTIONSFOR LEVEL 4 & 5 DRAINAGE.
2" AIR SPACE
BRICK VENEER
DRAIN - SEEPLUMBING
WINDOW - REFER TOTYP. WINDOW JAMBDETAIL
CONTINUOUS AIR BARRIER(WHERE INDICATED WITH ADASHED LINE)
5/8" TYP 'X' EXTERIORGRADE WALL BOARD.
BREAK METAL CLOSURETO MATCH WINDOWFRAME - SEE ELEVATIONS
WD. BLOCKING @CORNER
BALCONY RAILING & POST
MAINTAIN 1 HR RATING
AT ALL EXTERIORBEARING CONDITIONS(SHADED)
STL. POST FRAMING -SEE STRUCTURAL
WINDOW - REFER TOTYP. WINDOW JAMBDETAIL
WINDOW NAILER
5/8" INTERIOR WALL BD.
TYP. WINDOW STOOL
LINE OF BRICK ABOVE
BALCONY FASCIA BELOW
WINDOW - REFER TOTYP. WINDOW JAMBDETAIL
CONTINUOUS AIR BARRIER(WHERE INDICATED WITH ADASHED LINE)
5/8" TYP 'X' EXTERIORGRADE WALL BOARD.
BREAK METAL CLOSURETO MATCH WINDOWFRAME - SEE ELEVATIONS
WD. BLOCKING @CORNER
BALCONY RAILING & POST
MAINTAIN 1 HR RATING
AT ALL EXTERIORBEARING CONDITIONS(SHADED)
STL. POST FRAMING -SEE STRUCTURAL
WINDOW - REFER TOTYP. WINDOW JAMBDETAIL
WINDOW NAILER
5/8" INTERIOR WALL BD.
TYP. WINDOW STOOL
BALCONY FASCIA BELOW
J.
CURTIS
MOODY
7066
© 2
015 M
oody/
Nola
n Inc.
for
Dwg. Coord.: Tech. Coord.:
PR
INT
DA
TE
:
FIL
E IN
FO
:
Phone: (614) 461-4664Fax: (614) 280-8881
www.moodynolan.com
300 Spruce StreetSuite 300Columbus, Ohio 43215 CURTIS J. MOODY, LIC. #7066
EXP. DATE: 12/31/2015
B2
KEY PLAN
CITY OF DUBLIN APPROVAL
MOONEY STREET
BA
NK
ER
DR
IVE
BR
IDG
E P
AR
K A
VE
NU
E
M OONEY STREET
LONGSHORE STREET
L ONGSHORE STREET
1/5
/ 2017 8
:10:0
2 A
M
C:\$$Loc a
l Revi
t P
roj e
cts\
2016 P
roje
c ts\
14145 -
Bridge P
ark
- B
LD
G B
2 -
AR
CH
_G
Briya
.rvt
A161
14145
08-03-2015
LEVEL 6 - FLOORPLAN
BRIDGE PARK BUILDING B2
Author Checker
GMP/PERMITSET
6580 RIVERSIDE DR. DUBLIN, OHIO 43017
PLAN 1/8" = 1'-0"
LEVEL 6 - FLOOR PLAN1
PLAN 1" = 1'-0"
LEVEL 6 - TYP. CORNER BALCONY2 PLAN 1" = 1' -0"
LEVEL 3, 4 & 5 - TYP. CORNER BALCONY3
DETAIL 3" = 1'-0"
CORNER BALCONY POST @ LEVEL 3, 4 & 54
DETAIL 3" = 1'-0"
CORNER BALCONY POST @ LEVEL 65
REFER TO SHEET A131 FOR DIMENSIONSAND WALL TYPES UNLESS NOTED ON PLAN
# DATE CHANGE DESCRIPTION
5 3-23-16 BULLETIN #4
7 5-27-16 BULLETIN 7
9 07-27-16 BULLETIN #2 R
11 Date 11 BULLETIN #13
13 12-22-16 BULLETIN #17
5
5
9
Approved forConstructionBPS.15-22369.COM.COM_EPR.1883.3621102/24/17