APPLICATIONS - pumpfundamentals.com · O-rings NBR Shaft AISI 420 Knuckle Noryl Drain pipe...
Transcript of APPLICATIONS - pumpfundamentals.com · O-rings NBR Shaft AISI 420 Knuckle Noryl Drain pipe...
Silent Box
�
0
53
5Qm3/h
Hm
CE
SILENT BOX
• Distribution of clear, pure water and rainwater• Irrigation • Sprinkling
• Distribution of drinking water • Pressure boosting• Washing
OPERATING RANGES
Flow rates up to : 5 m3/hPressure head up to : 53 mCEOperating pressure : 8 barMax. water temperature : +5°à 35°CMax. ambient temperature : 40°COrifice DN : �”Max. suction head : 8 m
APPLICATIONS
ADVANTAGES
• 43 dB(A) low-level noise running• Plastic shell• All-in-one concept• Built-in check valve• On/off operation• Dry running protection• Adjustable starting pressure• Draining pipe• Simple connections• The pump rests on silent blocks• Built-in filling funnel
DomeStic BooSting SyStem50 Hz
N.T. N° 141-12/ENG - Ed. 2/04-07
• Silent Box
Silent Box
�
0 5
10 15 20 25 30 35 40 45 50
1 0 0
0
0
0
2 3 4
1 2 3 4
1 2 3 4 0,3 0,4 0,5 0,6 0,7
ISO 9906
0 1 2 3 4
204
203
205
60 1 1,2 0,8 0,6 0,4 0,2
40 20
N.P.S.H. m
Qm3/h
Qm3/h
Qm3/h
Hm
P2 kW
Imp.gpm
Ql/min
Ql/s
SILENT BOX 50Hz
DESIGN
• Hydraulics :- Horizontal pump - Axial suction and upwards vertical discharge with threaded orifices
- Impellers mounted directly on the motor’s extended shaft
- Hydraulic assembly assembled at 8 points to a lantern ring
- Shaft/motor leaktightness ensured through a mechanical seal
• Motor- Ventilated 2 pole dry motor- Single-phase: thermal protection with auto-matic repriming
Speed : 2900 rev/minSingle-phase winding : 230 VFrequency : 50hzInsulation class : 155 (F)Protection index : IP 54CE compliance : NF E
BASIC CONSTRUCTION
Main parts MaterialImpellers NorylStage body NorylMechanical seal Carbon-resin/NitrileO-rings NBRShaft AISI 420Knuckle NorylDrain pipe Transparent PVCPump body AISI 304 stainless
steelCasing PolypropyleneAcoustical foam PolyurethanePlugs Noryl
IDENTIFICATION
SILENTBOX � 03- M /EV
Pump code
Nominal flow rate in m3/hr
Number of stages
M : single-phase motor
Eau de ville
HYDRAULICS PERFORMANCES
CONTROL PANEL AND AUTOMATIC DEVICE
Main functions*1 ON/OFF BUTTON Pressing the button for 2 seconds will automatically prime the pump.
The button also allows the manual repriming of the pump in the event of a fault
2 OPERATING INDICATOR The pump is in operation
3 VOYANT ATTENTE DE MARCHE The pump is connected to the mains electricity supply
4 FAULT INDICATOR The pump is in «alarm“ mode : dry running protection
5 STARTING PRESSURE ADJUSTING The pump is factory preset at 1.5 bar. The pressure can be adjusted from 0.7 bars to 3.5 bars (see photos)
* For more information about these functions, refer to the installation manual
NB:Attention �03 EV version is only available in non self-priming version.
Silent Box
3
9220
99443011A
9901
3011B9902A4213 4610C
11541160B
1160A
6545A
225065214610A1111
4610D
11659647
4610B6515
1170
3±0,5002
SB 2050.75kW - 1~
SB 2040.55KkW - 1~
99031160
03
9941
9923C
2460B4220
42402540
9830
8110 9831
98209822
Rp 1"
Rp1"
6545B 6571
Rp 1"
Rp1"
2460A
SB-MP 2030.55KkW - 1~
Rp 1"
Rp1"
2460A
9220
99443011A
9901
3011B9902A4213 4610C
11541160B
1160A
6545A
225065214610A1111
4610D
11659647
4610B6515
1170
3±0,5002
SB 2050.75kW - 1~
SB 2040.55KkW - 1~
99031160
03
9941
9923C
2460B4220
42402540
9830
8110 9831
98209822
Rp 1"
Rp1"
6545B 6571
Rp 1"
Rp1"
2460A
SB-MP 2030.55KkW - 1~
Rp 1"
Rp1"
2460A
9927
6512
9805
9917
9800
6515
4610A
9629 6517 9635 9632 4590
6110 9906 9941
9803 6140 9902B 9923B 9901 9855 9860 9694
8360
Pièces de blocagepour le transport
4610A 6521 2541 3712 1400 9608 4610D 3690 4590 8070 9824 9900 9880 98079675
SECTIONAL DRAWING
1111 - 6 Stage casing body 1160A - stage body with interstage crossover 1154 - Diffuser stage 1170 - Check valve stage 1160 - Valve holder stage 1160B - interstage crossover 2250 - Impellers
3011A - bearing 3011B - bearing 2540 - Rubber deflector 4610B - seal 4610C - o-ring 4610D - o-ring 6545A - 1/2 snap ring
6545B - retaining ring 6571 - Tie rod 8110 - Housing 9220 - Impeller shaft 9647 - Metal valve 9820 - Motor fan 9822 - Fan cover
9831 - Rear bearing flange 4213 - Step holder bottom 9923C - nut 9941 - Washer 9944 - Elastic washer 9902A - screw
3690 - Sensor mounting 3712 - Knuckle nut 1400 - Discharge knuckle 9608 - Flow rate sensor 6515 - Draining plug 4610D - o-ring
4610A - o-ring 6512 - Filling funnel 6521 - Filling plug 9927 - Fine thread nut 9635 - Draining union 9675 - Flow rate sensor Retaining fork
6517 - Flexible pipe 8360 - Wire harness 9860 - Capacitor - 9803 - Base - 9800 - Cover - 9917 - Screw
9805 - Hydraulic trap 9807 - Control panel 9880 - Push button 8070 - Printed circuit board 9824 - Pcb protector hood
Silent Box
4
29033
4
181,5
128
507
279
300
G1"
G1"
187,3
H A
700
mm
M
IN
100 mm MIN
OPTION50
0 m
mM
IN
OU/OR
OPTION
REFERENCE DE COMMANDE
P� I Condensateur masse Câble électrique kW 1x 230
AµF avec emballage
kgsans emballage
kgm
SILENT BOX-EV203 M 0,55 4,2 12 17 11,4 1,5
SILENT BOX204- M 0,55 4,2 12,5 18 11,4 1,5
SILENT BOX205- M 0,75 5,4 16 18 13,9 1,5Câble H07RNF avec fiche
53, bd de la République - Espace Lumière - Bât. 6 - 78403 Chatou Cedex(no Indigo) SALMSON Contact : 0 8�0 0000 44
Fax. : 01 30 09 82 82 | www.salmson.com
INSTALLATION DIAGRAMS
1 - Check valve2 - Filling plug3 - Draining plug4 - Silent block5 - Power cable6 - On/off button7 - Connecting knuckle8 - Foot valve with strainer9 - Suction valve10 - Check/discharge valve
11 - Piping mounting12 - Strainer13 - Tank14 - Suction valve15 - Tank
ELECTRICAL AND DIMENSIONAL PROPERTIES
ORDER REFERENCE
P� I Capacitor Weight Electric cablekW 1x 230
AµF with packaging
kgwithout packaging
kgm
FEATURES
a) Electrical - 230 V-50 hz single-phase (M) with built-in thermal protection and automatic repriming.
- Built-in capacitor.
b) Assembly- Installation in a suction or charge fixed configuration.
- No need to secure to the ground. - The silent blocks absorb the system’s vibrations
- Connection through flexible pipes with rein-forcing helix
- Strainer recommended- Foot valve recommended for pump in a suction configuration
c) Packaging- Delivered ready to use; prewired with plug d) Maintenance- Assembly/dismantling instructions delive-red with the pump
ACCESSORIES
• Suction kit• Isolating valves• Strainer• Foot valve with strainer• Bladder tanks
STARKITSuction kit with 7 m hose, foot valve/strainer, and two fittings (suction and discharge)
ORDER REFERENCE ITEM PART NUMBERSTARKIT G1 (for SILENT BOX 204, 205)
4027874
53, bd de la République - Espace Lumière - Bât. 6 - 78403 Chatou Cedex - FRANCE(no Indigo) SALMSON Contact : +33 (0)8�0 0000 44
Fax. : +33 (0)1 30 09 82 82 | www.salmson.com