600 x 600 x 600mm POWER MANHOLE WITH CAST IRON FRAME
AutoCAD SHX Text
MCCB {RATING AS INDICATED}
AutoCAD SHX Text
MCB/MCCB {RATING AS INDICATED}
AutoCAD SHX Text
DISTRIBUTION BOARD TO SPECIFICATIONS
AutoCAD SHX Text
EARTHING POINT
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
LUMINAIRES
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
THREE PHASE ISOLATOR {RATING AS INDICATED} AS MEM
AutoCAD SHX Text
SWITCHGEAR
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
WIRING ACCESSORIES
AutoCAD SHX Text
13A TWIN MOULDED SWITHED SOCKET PLATE @ 300mm
AutoCAD SHX Text
13A SINGLE MOULDED SWITCHED SOCKET PLATE @ 300mm AFFL
AutoCAD SHX Text
AND COVER.
AutoCAD SHX Text
ADAPTABLE BOX
AutoCAD SHX Text
250 x 200 x 200mm METALCLAD FLUSH MOUNTED POWER
AutoCAD SHX Text
20A DP SWITCH WITH NEON INDICATOR
AutoCAD SHX Text
LIGHTING SWITCH - ONE GANG ONE WAY ARCHITRAVE
AutoCAD SHX Text
LIGHTING SWITCH - TWO GANG ONE WAY
AutoCAD SHX Text
LIGHTING SWITCH - TWO GANG ONE WAY ARCHITRAVE
AutoCAD SHX Text
LIGHTING SWITCH -FOUR GANG ONE WAY
AutoCAD SHX Text
TV
AutoCAD SHX Text
D
AutoCAD SHX Text
TELEVISION OUTLET
AutoCAD SHX Text
RJ45 OUTLET FOR DATA
AutoCAD SHX Text
T
AutoCAD SHX Text
RJ45 OUTLET FOR TELEPHONE
AutoCAD SHX Text
D1
AutoCAD SHX Text
EXIT
AutoCAD SHX Text
CONSUMER UNIT
AutoCAD SHX Text
WS
AutoCAD SHX Text
LAN WIRELESS STATION WITH SINGLE 13A SOCKET (NON SWITCHED) AND SINGLE CAT6A RJ45 OUTLET
AutoCAD SHX Text
13A 240V TWIN SOCKET OUTLET ABOVE WORK TOP
AutoCAD SHX Text
AUDIO VISUAL OUTLET (MOUNTED ON TABLE) WITH 1No. TWIN SOCKET OUTLET,1No,DUAL DATA CAT 6A RJ45 OUTLET,1No.HDMI OUTLET,1No.VGA OUTLET.
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
LAN
AutoCAD SHX Text
LOCAL AREA NETWORK CABINET
AutoCAD SHX Text
2C
AutoCAD SHX Text
FIRE ALARM & SECURITY INSTALLATIONS
AutoCAD SHX Text
ADDRESSABLE IONISATION SMOKE DETECTOR AS MENVIER CEILING/
AutoCAD SHX Text
ADDRESSABLE SECURITY ALARM BREAK GLASS MANUAL CALL POINT
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
CR
AutoCAD SHX Text
CARD READER/BIOMETRIC READER
AutoCAD SHX Text
MAGNETIC CONTACT
AutoCAD SHX Text
AS MENVIER MOUNTED AT 1400mm A.F.F.L
AutoCAD SHX Text
SLAB MOUNTED
AutoCAD SHX Text
INTRUDER DETECTION SYSTEM KEYPAD
AutoCAD SHX Text
C
AutoCAD SHX Text
PIR
AutoCAD SHX Text
CCTV CAMERA POINT WALL MOUNTED
AutoCAD SHX Text
PASSIVE INFRARED POINT WALL MOUNTED
AutoCAD SHX Text
MC
AutoCAD SHX Text
KP
AutoCAD SHX Text
MAGNETIC LOCK
AutoCAD SHX Text
ML
AutoCAD SHX Text
ADDRESSABLE IONISATION HEAT DETECTOR AS MENVIER CEILING/
AutoCAD SHX Text
SLAB MOUNTED
AutoCAD SHX Text
PANIC BUTTON
AutoCAD SHX Text
PB
AutoCAD SHX Text
EX
AutoCAD SHX Text
REQUEST TO EXIT
AutoCAD SHX Text
BG
AutoCAD SHX Text
PIR
AutoCAD SHX Text
PASSIVE INFRARED POINT CEILING MOUNTED
AutoCAD SHX Text
C
AutoCAD SHX Text
CCTV CAMERA POINT CEILING MOUNTED
AutoCAD SHX Text
ADDRESSABLE FIRE ALARM BREAK GLASS MANUAL CALL POINT AS
AutoCAD SHX Text
& SOUNDER AS MENVIER MOUNTED AT 1400mm& 2100 A.F.F.L
AutoCAD SHX Text
OVERRIDE SWITCH (KEYED)
AutoCAD SHX Text
OS
AutoCAD SHX Text
FAP
AutoCAD SHX Text
FIRE ALARM PANEL
AutoCAD SHX Text
SD
AutoCAD SHX Text
HD
AutoCAD SHX Text
CCTV MONITOR
AutoCAD SHX Text
DITTO AS TYPE 2C VERSION BUT WITH EMERGENCY KIT AS ROBUS SPACE LED R326060LED-CWE, TYPE 2CE.
AutoCAD SHX Text
ALUMINIUM FINISH MAIN VOLTAGE DIE CAST ADJUSTABLE DOWNLIGHT WITH 50W GU10 LAMP AS MICROMARK MM31216 OR EQUAL AND APPROVED. TYPE D1.
AutoCAD SHX Text
CEILING RECESSED 25W LED DOWNLIGHT AS ROBUS ETERNITY R2530DL OR EQUAL AND APPROVED EQUIVALENT, AS TYPE D2.
AutoCAD SHX Text
D2E
AutoCAD SHX Text
D2
AutoCAD SHX Text
DITTO AS TYPE D2 VERSION BUT WITH EMERGENCY KIT, TYPE D2E.
AutoCAD SHX Text
4
AutoCAD SHX Text
LX28W T5/T16 BARE BATTEN FLUORESCENT FITTING WITH HIGH FREQUENCY BALLAST ASTHORN POPPACK PRO 96239876. TYPE 4
AutoCAD SHX Text
CEILING MOUNTED MAINTAINED LED EXIT SIGN AS ROBUS LED BLADE RE430M-01 2711 OR EQUAL AND APPROVED.TYPE EXIT.
AutoCAD SHX Text
32W 600X600MM CEILING RECESSED LED FITTINGS SLIM PROFILE AS ROBUS SPACE LED PANEL LIGHTS R326060LED-CW OR EQUAL AND APPROVED, TYPE 2C
AutoCAD SHX Text
RESPECTIVELY
AutoCAD SHX Text
FB
AutoCAD SHX Text
FLOOR BOX WITH 1 NO. TWIN STD SOCKET, SINGLE RJ45 FACE PLATE AND HDMI FACE PLATE
AutoCAD SHX Text
SINGLE PHASE INDUSTRIAL SOCKET, (RATING AS INDICATED).
AutoCAD SHX Text
13A 240V FUSED UNSWITCHED SOCKET OUtLET
AutoCAD SHX Text
13A NON STANDARD TWIN MOULDED SWITCHED
AutoCAD SHX Text
DITTO AS ABOVE BUT SINGLE MOULDED (UPS POWER).
AutoCAD SHX Text
SOCKET PLATE @ 300mm AFFL (UPS POWER)
AutoCAD SHX Text
15A SINGLE SOCKET PLATE
AutoCAD SHX Text
PCL
AutoCAD SHX Text
6W LED PICTURE LIGHT AS EGLO IMENE 92095 OR EQUAL AND APPROVED EQUIVALENT. TYPE PCL
AutoCAD SHX Text
LIGHTING SWITCH - ONE GANG TWO WAY
AutoCAD SHX Text
LIGHTING SWITCH - TWO GANG TWO WAY
AutoCAD SHX Text
LIGHTING SWITCH - THREE GANG ONE WAY
AutoCAD SHX Text
LIGHTING SWITCH - THREE GANG TWO WAY
AutoCAD SHX Text
SINGLE PHASE ISOLATOR {RATING AS INDICATED} AS MEM
AutoCAD SHX Text
DITTO AS TYPE 2B VERSION BUT WITH EMERGENCY KIT, TYPE 2BE.
AutoCAD SHX Text
45W 600X600MM ANALOGUE DIMMABLE CEILING RECESSED LED FITTINGS SLIM PROFILE AS ROBUS SPACE LED PANEL LIGHTS R456060LED-CWAD OR EQUAL AND APPROVED, TYPE 2B
AutoCAD SHX Text
RECTANGULAR RECCESSED (85MMX 150MM) WITH ALUMINIUM FINISH ADJUSTABLE DOWNLIGHT WITH 2X35W GU10 LAMP AS MASSIVE APOLLO 59502/48/10 OR EQUAL AND APPROVED. TYPE D1A.
AutoCAD SHX Text
a-g
AutoCAD SHX Text
LIGHTING SWITCH GANG
AutoCAD SHX Text
LIGHTING SWITCH -ONE GANG ONE WAY DIMMER
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
DRAWING No.
AutoCAD SHX Text
STATUS
AutoCAD SHX Text
Drawing Title
AutoCAD SHX Text
Designed by
AutoCAD SHX Text
Job No.
AutoCAD SHX Text
Checked by
AutoCAD SHX Text
Scale
AutoCAD SHX Text
Drawn by
AutoCAD SHX Text
Date
AutoCAD SHX Text
ACAD File:
AutoCAD SHX Text
Approved by
AutoCAD SHX Text
REV
AutoCAD SHX Text
Project
AutoCAD SHX Text
Client
AutoCAD SHX Text
REV
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
BY
AutoCAD SHX Text
BY
AutoCAD SHX Text
BY
AutoCAD SHX Text
BY
AutoCAD SHX Text
R E V I S I O N S
AutoCAD SHX Text
SIGN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
Architects
AutoCAD SHX Text
P0
AutoCAD SHX Text
APRIL 2020
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
P0
AutoCAD SHX Text
P
AutoCAD SHX Text
1806 -KRA Offices-E-000-P0
AutoCAD SHX Text
1806 -KRA Offices-E-000-P
AutoCAD SHX Text
ELECTRICAL LEGEND & SYMBOLS
AutoCAD SHX Text
PHASE 1 -ELECTRICAL INSTALLATIONS
AutoCAD SHX Text
1806
AutoCAD SHX Text
PROPOSED INTERIOR DESIGN FIT OUT FOR KRA,
AutoCAD SHX Text
CBC UPPERHILL, NAIROBI
LIFT
LIFT
Balcony
Balcony
DEPUTYCOMMISSIONER
(Litigation)
CHIEFMANAGERLeti.Expt 01
CHIEFMANAGERLeti.Expt 02
CHIEFMANAGER
Leti.a
CHIEFMANAGER
Leti.b
CHIEFMANAGER
Leti.c
LETI.OFF
LETI.Supp
LETI.OFF 01
LETI.OFF 02
LETI.AM.a 01
LETI.AM.a 02
LETI.AM.a 03
LETI.AM.a 04
LETI.AM.c 01
LETI.AM.c
02
LETI.AM.b 04
LETI.Sup.c 01
LETI.Sup.c 02
LETI.Sup.c 03
LETI.Sup.c 04
LETI.Sup.a 01
LETI.Sup.a 02
LETI.Sup.a 03
LETI.Sup.a 04
LETI.Off.a 06
LETI.Off.a 04
LETI.Off.a 01
LETI. aMan 01
LETI. aMan 02
LETI. cMan 01
LETI. bMan 01
LETI.AM.c 03
LETI.AM.c 04
LETI.Off.a 02
LETI.Off.a 03
LETI.Sup.b 02
LETI.Sup.b 01
LETI.Sup.b 03
LETI.Sup.b 04
LETI.Off.b 01 LETI.
Off.b 02LETI.
Off.b 03
LETI.CM. Off
01
LETI.CM. Off
02
DataCabinet
DataCabinet
LETI.Off.c 01
LETI.Off.c 04
WAITINGLOUNGE
LETI. cMan 02
LETI.Off.a 05
LETI. bMan 02
LETI.AM.b 01
LETI.Off.c 02
LETI.Off.c 05
LETI.Off.c 03
T.V
LETI.AM.b 02
LETI.AM.b 03
LETI.Off.b 04
LETI.Off.b 05
Pupil01
Pupil02
Pupil01
Pupil02
Pupil03
Pupil04
Lockers
Lockers
Lockers
Lockers
Lockers Lockers
LockersLockers
STAFFBREAK-OUT
ROBINGROOM
LIFT
LO
BBY
WORKSTATIONS 31No.LITIGATION
WORKSTATIONS 28No.LITIGATION
F
LIFT
LIFT
DB-C1 DB-U4
DB-C2 DB-U5
LAN
HDMI
C1-2R
U4-1RC1-2R
C1-2RU4-1R
C1-2YU4-1Y
C1-2YU4-1Y
C1-2YU4-1Y
C1-2BU4-1B
C1-2BU4-1B
C1-3RU4-2R
C1-3RU4-2R C1-3R
U4-2R
C1-3YU4-2Y
C1-3BU4-2B
C1-3BU4-2B
C1-3B
C1-4RU4-3R
U4-3Y
U5-1RC2-2R
C2-2R
U5-1RC2-2R
U5-1RC2-2R
U5-1YC2-2Y
U5-1YC2-2Y
C2-2Y
U5-1YC2-2Y
U5-1YC2-2Y
U5-1YC2-2Y
C2-2Y
U5-1BC2-2B
U5-1BC2-2B
U5-1BC2-2B
U5-2RC2-3R
U5-2RC2-3R
U5-2RC2-3R
U5-2RC2-3R
U5-2YC2-3Y
U5-2YC2-3Y
U5-2YC2-3Y
U5-2YC2-3Y
U5-2YC2-3B
C2-3B
C2-3Y
C2-4R
C2-4R
U5-2BU5-2B
C2-4B
U5-2B
U5-3R
C1-2R
C2-3B
VT
C1-2Y
C2-2R
U4-3B
C2-4YC2-4Y C2-4Y
C2-5R
FB
LAN
C2-2Y
C1-3RC1-2B
C2-2Y
D
DD
DD
D
DD
DD
DD DD
DD
DD
D
D D
D
DD
D
DD
DD
DD
D D
D
D
DD
DD
DD
D
DD
DD
DD
D
D D
D
D
D D
D D
D
D
D D
D D
D
C2-4Y
D
KENYA REVENUE AUTHORITY
AutoCAD SHX Text
200 X 50 mm 2-COMPARTMENT TRUNKING
AutoCAD SHX Text
1X25 MM + 1X32 MMCONDUIT LINK IN SLAB
AutoCAD SHX Text
200 X 50 mm 2-COMPARTMENT TRUNKING
AutoCAD SHX Text
200 X 50 mm 2-COMPARTMENT TRUNKING
AutoCAD SHX Text
200 X 50 mm 2-COMPARTMENT TRUNKING
AutoCAD SHX Text
200 X 50 mm 2-COMPARTMENT TRUNKING
AutoCAD SHX Text
200 X 50 mm 2-COMPARTMENT TRUNKING
AutoCAD SHX Text
50 X 200 mm 2-COMPARTMENT TRUNKING
AutoCAD SHX Text
2NO. 20 mm CONDUITLINK IN SLAB
AutoCAD SHX Text
1X25 MM + 1X32 MMCONDUIT LINK IN SLAB
AutoCAD SHX Text
2NO. 200 X 50 mm CABLE TRAY
AutoCAD SHX Text
TRUNKING DROP
AutoCAD SHX Text
2X25 MM +1X32 MM CONDUITDROPS
AutoCAD SHX Text
TRUNKING DROP
AutoCAD SHX Text
TRUNKING DROP
AutoCAD SHX Text
TRUNKING DROP
AutoCAD SHX Text
TRUNKING DROP
AutoCAD SHX Text
2NO. 200 X 50 mm CABLE TRAY
AutoCAD SHX Text
2X25 MM +1X32 MM CONDUITDROPS
AutoCAD SHX Text
2NO. 200 X 50 mm CABLE TRAY
AutoCAD SHX Text
2NO. 200 X 50 mm CABLE TRAY
AutoCAD SHX Text
2NO. 200 X 50 mm CABLE TRAY
AutoCAD SHX Text
TRUNKING DROP
AutoCAD SHX Text
2X25 MM +1X32 MM CONDUITDROPS
AutoCAD SHX Text
2X25 MM +1X32 MM CONDUITDROPS
AutoCAD SHX Text
2NO. 200 X 50mm CABLE TRAY
AutoCAD SHX Text
TRUNKING DROP
AutoCAD SHX Text
TRUNKING DROP
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
DRAWING No.
AutoCAD SHX Text
STATUS
AutoCAD SHX Text
Drawing Title
AutoCAD SHX Text
Designed by
AutoCAD SHX Text
Job No.
AutoCAD SHX Text
Checked by
AutoCAD SHX Text
Scale
AutoCAD SHX Text
Drawn by
AutoCAD SHX Text
Date
AutoCAD SHX Text
ACAD File:
AutoCAD SHX Text
Approved by
AutoCAD SHX Text
REV
AutoCAD SHX Text
Project
AutoCAD SHX Text
Client
AutoCAD SHX Text
REV
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
BY
AutoCAD SHX Text
BY
AutoCAD SHX Text
BY
AutoCAD SHX Text
BY
AutoCAD SHX Text
R E V I S I O N S
AutoCAD SHX Text
SIGN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
Architects
AutoCAD SHX Text
APRIL 2020
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
P2
AutoCAD SHX Text
P
AutoCAD SHX Text
1806 -KRA Offices-E-002-P2
AutoCAD SHX Text
1806 -KRA Offices-E-002-P
AutoCAD SHX Text
THIRD FLOOR
AutoCAD SHX Text
POWER LAYOUT
AutoCAD SHX Text
PHASE 1 - ELECTRICAL INSTALLATIONS
AutoCAD SHX Text
1806
AutoCAD SHX Text
PROPOSED INTERIOR DESIGN FIT OUT FOR KRA,
AutoCAD SHX Text
CBC UPPERHILL, NAIROBI
P.S.bSup. 01
P.S.bAM
P.S.bSup. 04
P.S.bSup. 03
P.S.bSup. 02
P.S.bSup. 05
LIFT
LIFT
DEPUTYCOMMISSIONER
(Board Coordination)
Balcony
Balcony
BOARDROOM 02(14/28PAX)
LOUNGE
CLOAKROOM
WORKSTATION 15No.OPERATIONS
WAITINGLOUNGE
CHIEF MANAGEROPERATIONS &
BTO
COMMISSIONER'SOFFICE
CMBTO Off
CM BTOSupp
BC.OFF
BC.Sup
B.S.TMan 01
B.S.TMan 02
G.C.TMan
B.S.TAM 01
B.S.TAM 02
B.S.TAM 03
O.TSup. 01
O.T.Sup. 02
O.T.Sup. 03
O.TSup. 04
Leg.Sec. 01
OT.OFF 01
OT.OFF 02
OT.OFF 03
OT.OFF 04
OT.OFF 05
P.S.aSup. 05
P.S.aSup. 04
P.S.aSup. 03
P.S.aSup. 02
P.S.aSup. 01
OT.OFF 06
OT.OFF 07G.C.T
AM
DataCabinet
DataCabinet
MEETINGROOM
T.V
ConfidentialRegistry
(6mm MS plate wall lining)
Leg.Sec. 02
Leg.Sec. 03
Leg.Sec. 04
Leg.Sec. 05
Leg.Sec. 06
filin
g
Man Admin& QA
OprtnMan
O.TAM 01
O.TAM 02
ManB.T.O
P.S.aAM
BTOAM 02
BTOAM 01
WORKSTATION 31No.OPERATIONS
Lockers
T.V
Lockers
Lockers Lockers
LockersLockers
LIFT
LO
BB
Y
KITCHENETTE
WORKSTATIONS 10No.BOARD AFFAIRS
FF
DD
DDD
DD
D
D
DD
DD
DD
DDDD
DD
D
PROJECTORPOINT INCEILING
FB FB
FBHDMI
DHDMI
D
LAN
LAN
DB-E1 DB-U8
DB-E2 DB-U9
U8-1B
E1-2RU8-2Y
E2-2R
DD
D
D
DDDDD
D
D
D
DD
DD
VT
HDMI
D
D D
E1-2R
E1-2RU8-1R
E1-2RU8-1R
E1-2RU8-1R
E1-2RU8-1R
E1-2Y
E1-2YU8-1Y
E1-2YU8-1Y
E1-2BU8-1Y
E1-2BU8-1YE1-2B
U8-1Y
E1-3R
E1-3R
U8-1BE1-3R
E1-3R
U8-1BE1-3R
E1-3R
U8-2RE1-3R
E1-3R
E1-3B
U8-2R
E2-2R
E2-2RU9-1R
E2-2RU9-1R
E2-2YU9-1R
E2-2YU9-1R
E2-2YU9-1R
E2-2YU9-1R
E2-2YU9-1R
E2-2BU9-1Y
E2-2BU9-1Y
E2-2BU9-1Y
E2-3RU9-1B
E2-3RU9-1B
E2-3RU9-1B
E2-3RU9-1B
E2-3YU9-2R
E2-3YU9-2R
E2-3YU9-2R
E2-3YU9-2R
E2-3Y
E2-3BU9-2Y
E2-3BU9-2Y
E2-3BU9-2Y
E2-3BU9-2Y
E2-4RU9-2B
E2-4R
E2-4R
E2-4B
E2-4YU9-2B
E2-4YU9-2B
E2-4YU9-2B
E2-4YU9-2B
U9-3R
U9-3Y
E2-5RD
D
D
D
D
D
FB
TRUNKING DROP
TRUNKING DROP
TRUNKING DROP
TRUNKING DROP 2No. 200x50mm CABLETRAY IN CEILING SPACE