    API PLAN 62 Installation of steam traps in steam quench

    The object of this technical note is to draw

    attention to a design of one of the most

    commonly used API Plan, the Plan 62. This

    document is focused on steam quench

    applications, where there are possible

    cases of typical arrangement that may

    generate some confusion.

    eading these lines, you may thin! that

    the case and solution proposed herein are

    ob"ious, and indeed they are. #owe"er,

    the design discussed below is present at

    many facilities, commercial document$

    tation, projects, etc.

    What does API 682 say about this Plan?

    Source: API 682 4thEdition (Figure !24"

  • 7/25/2019 API PLAN 62_Installation of Steam Traps in Steam Quench

    2/3

    urfing through the internet, it is easy to

    find some documents, images and other

    documentation with a particular

    installation for the steam trap.

    The following pictures shown the steam

    trap assembled in the same pipe which

    pro"ides the quench to the mechanical

    seal )in$line. As the steam trap pre"ents

    the passage of steam through it, only

    condensate, and not steam, will reach to

    the seal.

    #et$s see so'e e,a'les:

    I'ages o- .API Plan 62 stea' /uench0 1 -ro'di--erent sources -ound through oogle I'ages!

  • 7/25/2019 API PLAN 62_Installation of Steam Traps in Steam Quench

    3/3

    I'ages o- .API Plan 62 stea' /uench0 1 endor

    3ra&ings!

    onclusion:

    The conclusion can be summed up in a

    simple sentence( /Install the steam trap

    properly0.

    Therefore, if the steam trap installation isas indicated in the e1amples, the steam

    will not reach the mechanical seal. The

    Plan will not meet its purpose and its

    effecti"e pre"ention of co!e built up,

    solids deposit, crystalliation, polymer$

    riation, etc.

    Additionally if the condensate is

    introduced in the mechanical seal and

    contact the seal faces, it can be

    responsible of early seal failures.

    ecommendations(

    3. team trap shall be installed in a

    branch line. 4epending on piping seal

    plan arrangement the installation can

    be as indicated in the s!etch bellow.

    2. team trap shall be located as close

    as possible to seal in the lowest

    location.

    5. It shall be agreed with end user

    where steam trap outlet is

    discharged and its configuration.

    API Plan 62&ith stea' /uench

    ose &uis Ayala arabia,

    otating 7quipment 7ngineer at Tecnicas eunidas .A.

    8onalo 9arrasco 8utierre,

    :echanical 7ngineer at abic