API 570 Study Question Flashcards
description
Transcript of API 570 Study Question Flashcards
![Page 1: API 570 Study Question Flashcards](https://reader038.fdocuments.in/reader038/viewer/2022102622/55cf978d550346d033924476/html5/thumbnails/1.jpg)
5/7/2014 API 570 study question Flashcards
http://www.flashcardmachine.com/api-570studyquestion.html 1/14
MyFlashcards FlashcardDB About Help Donate TellFriends!
create, study and share online flash cards
Title
Description
Total Cards
Subject
Created
Home >> Flashcards >> Other >> API 570 study question
Shared Flashcard Set
Details
API 570 study question
API 570 Code
68
Other
05/19/2013
Click here to study/print these flashcards.
Create your own flash cards! Sign up here.
Additional Other Flashcards
Cards
Term
The service (s) that has potential fornone or very few CMLs on circuit
Definition
1. Olefin Cold Side,2. Anhydrous Ammonia
Answer found API 570: 5.6.2
Term
Service (s) that Valves should beinspected for thermal fatigue
Definition
Cat Reformer
See API 570 section 5.10
Term
Service(s) with reatively uniformcorrosion
Definition
1. Sulfidation,2. Sour Water
Answer found API 570: 5.6.3
Term
What class abbreviation is used to help
define the
Definition
JOC
J= one who is autherized by the
Jurisdiction
AWS CWI Welding Inspectoreurotechworld.net
Most intensive and interactive course for AWS Certified Inspector
![Page 2: API 570 Study Question Flashcards](https://reader038.fdocuments.in/reader038/viewer/2022102622/55cf978d550346d033924476/html5/thumbnails/2.jpg)
5/7/2014 API 570 study question Flashcards
http://www.flashcardmachine.com/api-570studyquestion.html 2/14
API 570 Repair OrganizationJurisdiction
O= Owner/User who repairs thier own
equipment
C= Contractor that is acceptble to
Owner/User
Answer found in API 570: 3.1.79
Term
What class abbreviation is used to help
define the
API 570 Authorized Inspection Agency
(AI's Employer)
Definition
JUIC
J= Inspection Org. of the Jurisdiction
U = Owner/User who maintians inspectionOrg.
I = Inspection Org. of an Insurance Company
C= Contractor employed by Owner /User
Answer found in API 570: 3.1.6
Term
The class abbreviation that is used to help:
Determine of corrosion Rate for New Service or
Change in Service
is?
Definition
SOPI
S= Same or Similar Service,
O= Owners Experience,
P= Published Data, or
I= Inspection in 3 months
Answer found in API 570:7.1.2
Term
What is the Class Abbreviation to helpreminber the
Primary Resonsiblities of API 570Authorized Inspector
Definition
TIE
T= Testing
I= Inspection
E= Examination
![Page 3: API 570 Study Question Flashcards](https://reader038.fdocuments.in/reader038/viewer/2022102622/55cf978d550346d033924476/html5/thumbnails/3.jpg)
5/7/2014 API 570 study question Flashcards
http://www.flashcardmachine.com/api-570studyquestion.html 3/14
Authorized InspectorE= Examination
Answer found in API 570: 4.3.4
Term
AIRRis the Class Abbreviation for?
Definition
API 570 Scope which is:
A = Alteration,
I = Inspection,
R = Repair,
R = Rerate.
Answer found in API 570: 1.1.1
Term
On repairs the minimum radius of an insert patch
is
Definition
Min of a 1" Radius
Answer found
API 570: 8.1.4.2.c/ Fig C.2
Term
When performing NDE inspection what is the
maximum diameter of the CML examination point
for lines equal to or less than 10 NPS
Definition
max dia. of 2"
Answer found API 570 : 3.1.20
Term
When performing NDE examinations of lines
greater than 10 NPS what is the maximum
diameter of the CML
Definition
Max dia. of 3"
Answer found API 570 : 3.1.20
Term
For partially buried pipe What is the soil-to-air
distance above the soil interface that is
considered for corrosion
Definition
6" above soil interace shall be considered
Answer found API 570:3.1.87
![Page 4: API 570 Study Question Flashcards](https://reader038.fdocuments.in/reader038/viewer/2022102622/55cf978d550346d033924476/html5/thumbnails/4.jpg)
5/7/2014 API 570 study question Flashcards
http://www.flashcardmachine.com/api-570studyquestion.html 4/14
Term
What is the distance below the soil interface to
dig when inspecting for soil-to-air corrosion
Definition
dig 6"-12" when inspection for soil-to-air
corrosion
Answer found API 570: 7.4.5
Term
For partially buried pipe What is the soil-to-air
distance below the soil interface that is to be
considered for corrosion
Definition
12" below soil interface
Answer found
API 570: 3.1.87
Term
At an Injection point curcuit what is the
minimum upsteam limit of a more extensive
examination.
Definition
minimum 12" upsteam of the injection
nozzle shall be examined
Answer found API 570: 5.5.9
Term
For underground piping what is the minimum
length of buried pipe to expose when
excavating for inspection
Definition
6 to 8 feet will need to be excavated for
inspection
Answer found API 570: 9.3.6
Term
Difine:
ALTERATION
Definition
Alteration is a Physical change in any component
that has design implications.
Note: Comparable or duplicate
replacements and the addition of small-bore
attachments that do not require reinforcement
or additional support are not considered an
alteration
Answer found in API 570: 3.1.2
Term
Define:
Repair
Definition
Restore to Suitablecondiction for safe operation at
designed condition
![Page 5: API 570 Study Question Flashcards](https://reader038.fdocuments.in/reader038/viewer/2022102622/55cf978d550346d033924476/html5/thumbnails/5.jpg)
5/7/2014 API 570 study question Flashcards
http://www.flashcardmachine.com/api-570studyquestion.html 5/14
Repair
Answer found in API 570: 3.1.78
Term
Define:
Defect
Definition
Defect is difined as
An Inperfection that exceedsacceptance criteria
Answer found in API 570: 3.1.17
Term
Define:
Inperfection
Definition
Discontinuity that may or may notexceed the acceptance criteria
Answer found in API 570: 3.1.30
Term
RBI's two Primary factors are?
Definition
1. Probability of failure2. Consequence of failure
Answer found in API 570:5.2
Term
What word is used to define thenumber of CML's to obtain thickness
readings during NDE inspection
Definition
Represent-ative
Representative sampling should includedata for all the various types of components
and orientations found in each cicuit.
Answer found in API 570: 6.5
Term
CML's that shall be measured during aThickness NDE Inspections, are?
Definition
CMLs with the earliest renewal date
as of the previous inspection
Answer found in API 570: 6.5
Term Definition
Performance
![Page 6: API 570 Study Question Flashcards](https://reader038.fdocuments.in/reader038/viewer/2022102622/55cf978d550346d033924476/html5/thumbnails/6.jpg)
5/7/2014 API 570 study question Flashcards
http://www.flashcardmachine.com/api-570studyquestion.html 6/14
Intervals for Pressure-relievingdevices (PRD's) are determined by:
Performance
The API 570 sec 6.7.3.1 states that PRD'sshall be tested and inspected at intervals thatare frequent enough to verify that the valves
perform reliably in the particular serviceconditions.
Answer found in API 570: 6.7.3.1
Term
API 570 PipingClassification Inspection scheme in
section 6.3.4 is based on:
Definition
Consequence of failure
See API 570 6.3.1
Term
Corrosion -Method by which processleaks can lead to brittle failure is
Definition
Auto-Refigeration
API 570 section 6.3.4.2.a
Term
Crrosion- Type of soil that is mostcorrosive is soil with
Definition
Low Resistivity
Answer found in
API 570 section 9.2.4
Term
Number of Repairs of new flangeassemblies to be inspected during
repairs and alterations is refered to as
Definition
Representative
API 570 section 5.12 States: The markings ona representative sample of newly installed
fasteners and gaskets should be examinedto determine whether they meet the material
specification.
Answer found API 570: 5.12
Term Definition
≤ 1 NPS
![Page 7: API 570 Study Question Flashcards](https://reader038.fdocuments.in/reader038/viewer/2022102622/55cf978d550346d033924476/html5/thumbnails/7.jpg)
5/7/2014 API 570 study question Flashcards
http://www.flashcardmachine.com/api-570studyquestion.html 7/14
What pipe size is RT preferred for thickness
readings
≤ 1 NPS
570: 5.7.1
Term
What is the pipe size where UT thickness
reading may require specialized UT equipment
Definition
≤ 2 NPS
570 5.7.1
Term
The term small bore piping refers to piping that
is
Definition
≤ 2 NPS
570 3.1.86
Term
What P-numbers allow the use of pre-heat in lieu
of PWHT
Definition
P1 & P3
570: 8.2.3.2
Term
For flanges, the thread engagement acceptance
criteria is
Definition
-1
570: 5.12
B31.3:335.2.3
Term
What is the minimum # of thremocouples
required when performing a local PWHT instead
of a 360 degree band
Definition
2
570:8.2.3.3.d
Term Definition
API 510
![Page 8: API 570 Study Question Flashcards](https://reader038.fdocuments.in/reader038/viewer/2022102622/55cf978d550346d033924476/html5/thumbnails/8.jpg)
5/7/2014 API 570 study question Flashcards
http://www.flashcardmachine.com/api-570studyquestion.html 8/14
When performing an InternalInspection on piping, What code
should be followed ?
API 510
Pressure Vessel InspectionCode
Answer found API 570 5.5.1
Term
What recommended practice is usedfor
Positive Meterial Indentification (PMI)
Definition
API 578
The Recommedned Pratice for:
Material Verification Program for Newand Existing Piping Systems
Answer can be found in API 570 sec 5.9
Term
What Standard is used for
Fitness for Service (FFS)
Definition
API 579
Answer is found in API 570: 7.4
Term
What Recommended Practice covers
Risk based Inspections
Answer found API 570: 5.2
Definition
API 580
Answer found in
API 570: 5.2
Term
Which standard covers
Valve Inspection and Testing
Definition
API 598
Answer is found API 570: 5.10
Term Definition
API 651
![Page 9: API 570 Study Question Flashcards](https://reader038.fdocuments.in/reader038/viewer/2022102622/55cf978d550346d033924476/html5/thumbnails/9.jpg)
5/7/2014 API 570 study question Flashcards
http://www.flashcardmachine.com/api-570studyquestion.html 9/14
What is the Recommended Practicefor
Cathodic Protection
Cathodic Protection of aboveground Petroleum
Storage Tanks
Answer found in API 570: 9.3.5
Term
When
Welding on In-Service Equipmentcontaining Flammbles,
What Publication shall be followed?
Definition
API 2201
Safe Hot Tapping Practices in theProtroleum and Petrochemical
Industries
Answer found in
API 570: 8.2.1
Term
What is the minimum flash point temp of
hydrocorbons used for leak testing
Definition
120°F
Answer found
API 570: 5.8.1
Term
At what temperature are special procedures
needed for UT thickness readings
Definition
>150°F
Answer found
API 570 5.7.1
Term
When welding, What minimum pre-heat temp is
substituted for PWHT
Definition
300°F
API 570: 8.2.3.2
Term
What is the minimum pre-heat temperature,
Definition
300°F
![Page 10: API 570 Study Question Flashcards](https://reader038.fdocuments.in/reader038/viewer/2022102622/55cf978d550346d033924476/html5/thumbnails/10.jpg)
5/7/2014 API 570 study question Flashcards
http://www.flashcardmachine.com/api-570studyquestion.html 10/14
What is the minimum pre-heat temperature,
when a local PWHT is substituted for a full
encirclement PWHT
570: 8.2.3.3.c
Term
When developing a Inspection plan, at what
operating temperature should a Corrosion
Specialist be consulted
Definition
>750°F
570:5.1.1.1
Term
What is the Minimum base metal temp during
pressure testing when the wall thickness is ≤ 2"
thick
Definition
(Minimum design metal temperature) MDMT +
10°F
570:5.8.3
Term
What is the Minimum base metal temp during
pressure testing when the wall thickness is > 2"
thick
Definition
(Minimum design metal temperature) MDMT +
30°F
570:5.8.3
Term
Whats the minimum duration of a hydro test to
evluate integrity of buried pipe
Definition
8 hr's
570: 9.3.7
Term
Whats the Maximum time for obtaining thickness
reading when corrosion rate on new pipe is not
known (no other data available)
Definition
3 months
API 570: 7.1.2.c
Term Definition
![Page 11: API 570 Study Question Flashcards](https://reader038.fdocuments.in/reader038/viewer/2022102622/55cf978d550346d033924476/html5/thumbnails/11.jpg)
5/7/2014 API 570 study question Flashcards
http://www.flashcardmachine.com/api-570studyquestion.html 11/14
Whats the suggested interval for above-grade
Visual surveillance of buried pipe
6 months
570: 9.3.1
Term
What is the length of time a API 570 AI must
recertify
Definition
3 years
API 570 A.3.1
Term
What is the max thickness inspection interval for
an injection point
Definition
Lesser 3yrs or 1/2 life
Term
What is the Max External Inspection interval for
Class 1 & 2 Piping
Definition
5 Years
API 570 6.7.3.2
Term
What is the Maximum Interval for Relief devices
in fouling or corrosive service
Definition
5 years
API 570: 6.7.3.2
Term
What is the suggested interval for closed-
interval Potential Survey of buried pipe with
poor CP
Definition
5 Years
API 570: 9.3.2
Term Definition
![Page 12: API 570 Study Question Flashcards](https://reader038.fdocuments.in/reader038/viewer/2022102622/55cf978d550346d033924476/html5/thumbnails/12.jpg)
5/7/2014 API 570 study question Flashcards
http://www.flashcardmachine.com/api-570studyquestion.html 12/14
Term
What the suggested interval fo evaluation of
Soil Corrosivity for buried pipe with no CP
Definition
5 years
API 570 9.3.4
Term
What is the max thickness inspection interval for
Class 1 Piping
Definition
Lesser of
5 years or 1/2 life
570 table 2
Term
What is the maximum interval for Relief devices
in non- fouling or no-corrosive srvice
Definition
10 years
570: 6.7.3.2
Term
Whats is the Maximum External Inspection
interval for Class 3 Piping
Definition
10 years
570: Table 2
Term
Whats the maximum Thickness Inspection
interval for Class 3 piping
Definition
10 years
570: table 2
Term
What the maximum interval for RBI Re-
assessment
Definition
Per table 2
570: 5.2.4
![Page 13: API 570 Study Question Flashcards](https://reader038.fdocuments.in/reader038/viewer/2022102622/55cf978d550346d033924476/html5/thumbnails/13.jpg)
5/7/2014 API 570 study question Flashcards
http://www.flashcardmachine.com/api-570studyquestion.html 13/14
Term
When should temporary welded piping repairs
be replaced
Definition
Next Opportunity
570: 8.1.4.1
Term
When shall non-welded repairs & temporary leak
sealing devices be removed and pipe repaired
Definition
Next turnaround
570: 8.1.5
Term
What is the maximum size fillet weld patch on
pipe repairs
Definition
Size of a the fillet weld patch should not exceed
1/2" the pipe diameter
Answer found
API 570: Fig C.2
Term
At an Injection point curcuit what is the
minimum upsteam limit that is to be examined
Definition
12" or 3 pipe dia. whichever is greater
Answer found
API 570: 5.5.9
Term
At an Injection point curcuit what is the
minimum downstream limit of a more extensive
examination
Definition
10 pipe dia. downstream of the injection point
Term
What is the minimum downstream limit of an
Injection point curcuit
Definition
Lesser of:
1st change in direction + 25'
or
2nd change in direction
![Page 14: API 570 Study Question Flashcards](https://reader038.fdocuments.in/reader038/viewer/2022102622/55cf978d550346d033924476/html5/thumbnails/14.jpg)
5/7/2014 API 570 study question Flashcards
http://www.flashcardmachine.com/api-570studyquestion.html 14/14
© 2001 - 2013 Flash Card Machine, LLC · Privacy Policy · Terms of Use Links · Flashcards
API 570: 5.5.9