AP-GC2 DATA SHEET Model: AP-GC2 Voltage: 6V Capacity (20HR): 210Ah Battery: VRLA AGM Color: Black @25 Amps @75 Amps 5 HR Rate 20 HR Rate LENGTH WIDTH HEIGHT TERMINAL HEIGHT GC2 AP-GC2 475 mins 124 min 185Ah 210 Ah 1, 2 260 (10.24) 180 (7.09) 254 (10) 274 (10.79) 66.1 (30) WEIGHT lbs. (kg) 6 VOLT DEEP CYCLE BATTERY CAPACITY MINUTES CAPACITY Amp Hours (AH) BCI GROUP SIZE TYPE TERMINAL TYPE DIMENSIONS mm (in) PRODUCT SPECIFICATIONS A. The number of minutes a battery can deliver when discharged at a constant rate of 80 F (27 C) and maintain a voltage above 1.75V/cell. Capacitites are based on peak performance. A System Voltage 6V 12V 24V 36V 48V Absorpon Charge 7.40 14.8 29.6 44.4 59.2 Float Charge 6.60 13.2 26.4 39.6 52.8 Equalize Charge 7.75 15.5 31.0 46.5 62.0 CHARGER VOLTAGE SETTINGS (AT 68°F/20°C) CHARGING INSTRUCTIONS DO NOT install or charge battery in a sealed or non-ventalated compartment. Constant under or overcharging will damage the battery and shorten its life as with any battery. Cycle Applications: Limit initial current to 52.5A. Charge until battery voltage (under charge) reaches 7.20 to 7.50 volts at 68 F (20 C). Hold at 7.20 to 7.50 volts until current drops to under 2.1A. Battery is fully charged under these conditions, and charger should be disconnected or switched to “float” voltage. “Float” or “Stand-By” Service: Hold battery across constant voltage source of 6.80 to 6.90 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Self Discharge: Due to self-discharge, it is important to charge these batteries within 6 months of storage. Otherwise sulfation may occur. TERMINAL CONFIGURATIONS 1 SAE SAE Automotive Post Terminal Terminal Height Decimals (mm) .95 (24) Torque Values in-lb (Nm) 50 - 70 (5.6 - 7.9) D (Posive / Negave) 19.5 / 17.9 2 5/16 Threaded Terminal Terminal Height Decimals (mm) 1.50 (38) Torque Values in-lb (Nm) 95 - 105 (10.7 - 11.9) Bolt Size 5/16 - 18 SIDE BY SIDE Type: Deep Cycle Long Life Container Material: Polypropylene Watering System: N/A 37.5 5/16” 1:9 19 24 30 17 20 D O O O Page 1 of 2 B B. See Terminal Configuration Chart.

Transcript of AP-GC2DATA SHEET - Amstron

AP-GC2DATA SHEETModel: AP-GC2

Voltage: 6V

Capacity (20HR): 210Ah

Battery: VRLA AGM

Color: Black

@25 Amps @75 Amps 5 HR Rate 20 HR Rate LENGTH WIDTH HEIGHT TERMINAL HEIGHT

GC2 AP-GC2 475 mins 124 min 185Ah 210 Ah 1, 2 260 (10.24) 180 (7.09) 254 (10) 274 (10.79) 66.1 (30)

WEIGHT lbs. (kg)

6 VOLT DEEP CYCLE BATTERY

CAPACITY MINUTES CAPACITY Amp Hours (AH)BCI GROUP SIZE

TYPE TERMINAL TYPE

DIMENSIONS mm (in)

PRODUCT SPECIFICATIONS

A. The number of minutes a battery can deliver when discharged at a constant rate of 80 F (27 C) and maintain a voltage above 1.75V/cell. Capacitites are based on peak performance.

A

System Voltage 6V 12V 24V 36V 48V

Absorption Charge 7.40 14.8 29.6 44.4 59.2Float Charge 6.60 13.2 26.4 39.6 52.8

Equalize Charge 7.75 15.5 31.0 46.5 62.0

CHARGER VOLTAGE SETTINGS (AT 68°F/20°C)CHARGING INSTRUCTIONS

DO NOT install or charge battery in a sealed or non-ventalated compartment. Constant under or overcharging will damage the battery and shorten its life as with any battery.

Cycle Applications: Limit initial current to 52.5A. Charge until battery voltage (under charge) reaches 7.20 to 7.50 volts at 68 F (20 C). Hold at 7.20 to 7.50 volts until current drops to under 2.1A. Battery is fully charged under these conditions, and charger should be disconnected or switched to “float” voltage.

“Float” or “Stand-By” Service: Hold battery across constant voltage source of 6.80 to 6.90 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition.

Self Discharge: Due to self-discharge, it is important to charge these batteries within 6 months of storage. Otherwise sulfation may occur.

TERMINAL CONFIGURATIONS1 SAE SAE Automotive Post Terminal

Terminal Height Decimals (mm).95 (24)

Torque Values in-lb (Nm)50 - 70 (5.6 - 7.9)

D (Positive / Negative)19.5 / 17.9

2 5/16 Threaded TerminalTerminal Height Decimals (mm)

1.50 (38)Torque Values in-lb (Nm)

95 - 105 (10.7 - 11.9)Bolt Size5/16 - 18

SIDE BY SIDE

Type: Deep Cycle Long Life

Container Material: Polypropylene

Watering System: N/A

37.5

5/16”

1:9 19 24

30

17

20

D

O O

O

Page 1 of 2

B

B. See Terminal Configuration Chart.

AP-GC2DATA SHEET

260 2

NEG

POS

180

2

254

2

274

2

BATTERY DIMENSIONS

DEPTH OF DISCHARGE

Cap

acity

(%

)

Expected Average Cyclemin h

75A 37A 25A 10.5A

DISCHARGE CHARACTERISTICS20 C, 68 Fo o

Discharge Time

Load

ing

Volta

ge (

V)

Amstron batteries are available worldwide through Amstron’s Distributor Network. We offer technical support, provided by our sales team and engineers.

For a Amstron Distributor near you,call 866.504.1634 or +818.504.1634 or visit www.amstron.com28337 Constellation Road, Valencia, CA 91355, USA

2015 Amstron Power Solutions. All rights reserved. Amstron Power Solutions is not liable for damages that may result from any information provided in or omitted from this publication, under any circumstances. Amstron Power Solutions reserves the right to make adjustments to this publication at any time, without notices or

obligation. Please check the Amstron website (www.amstron.com) for the most up-to-date information.Page 2 of 2

CYCLE LIFE RELATION

0 200 400 600 800 1000 1200 1400

120

100

80

60

40

20

1 3 5 10 18 30 60 2 3 5 10 20

6.5

6.0

5.5

5.25

5.0

4.5

4.0

0