Anova Precision Manual Print (3)

26
AnovA Anova Culinary LLC Houston, TX USA TEL: 281-980-1236 FAX: 281-980-1352 www.anovaculinary.com Precision TM Cooker Sous Vide Circulator Operating Manual

description

Manual

Transcript of Anova Precision Manual Print (3)

Page 1: Anova Precision Manual Print (3)

AnovA

Anova Culinary LLCHouston, TX USA TEL: 281-980-1236FAX: 281-980-1352www.anovaculinary.com

PrecisionTM Cooker Sous Vide CirculatorOperating Manual

Page 2: Anova Precision Manual Print (3)
Page 3: Anova Precision Manual Print (3)

Intellectual PropertyAll Intellectual Properties, as defi ned below, owned by or which is otherwise the property of Anova Industries, Anova Culinary LLC or its suppliers relating to Anova products, including but not limited to, accessories, parts or software relating thereto, are proprietary to federal and state laws, and international treaty provisions. Intellectual Property includes but is not limited to, inventions (patentable or unpatentable), patents, trade secrets, copyrights, software, fi rmware, computer programs, and related documentation and other works of authorship. Moreover, you agree that you will not, and will not attempt to, modify, prepare derivative works of, reverse engineer, disassemble the Anova products, decompile or otherwise attempt to create source code from the related software/fi rmware. No title to or ownership in Intellectual Property is transferred to you. All ap-plicable rights of the Intellectual Property shall remain with Anova Culinary LLC and its suppliers.

TABLE OF CONTENTSOperational Safety 4-5Introduction 6-7 Setup 8 Clamp & Pot 9-10 Pump Direction 11 Set Temp 12 Start/Stop 13 Change C/F Units 14 Bluetooth Pairing 15 Timer 16 Small Pots 17Maintenance 18 Assembly 19 Skirt/Pump 20 Cleaning 21 Stains 22Warranty Provisions 23Trouble Shooting/FAQ 24-25

Page 4: Anova Precision Manual Print (3)

OPERATION SAFETYThis section explains the potential dangers that may arise when operating the Anova PrecisionTM cooker sous vide circulator and notes many important safety precautions.

Counter tops such as marble and Corian cannot withstand the heat generated by the circulator. Place cooking container different surface to prevent damage.

Do not use extension cords. Never oper-ate with a damaged cord or plug. Use properly grounded electrical outlets only.

Do not immerse system past the top etch mark of stainless steel skirt. Only the stain-less steel skirt and the pump housing are dishwasher safe. Unplug from outlet when not in use and before the cleaning pro-cess.

Burn Hazard - the cooking container, the stainless steel portion of circulator, and food pouches all get hot when used. Use oven mitts or tongs when handling. Allow system to cool before emptying the water bath.

4

Page 5: Anova Precision Manual Print (3)

This system is an indoor appliance and is not a toy.

If your circulator falls into water, discon-nect power ASAP to avoid shock. Then send back system to repair (water dam-age not covered by warranty). Do not retrieve the unit until you have unplugged the cord. Do not attempt to use the sys-tem if this has happened.

DO NOT DISASSEMBLE. OBSERVE ALL WARNING LABELS. Do not remove warning labels.

Do not use this appliance for anything other than intended use. (Like laboratory work or heating a hot tub)

Firmly lock the circulator on the bath tank with the screw clamp - Place the con-tainer on an even surface to prevent spills and tipping over. Do not place unit on a stove, or in an oven.

5

DO NOT USE DEIONIZED WATER (DI water)

Page 6: Anova Precision Manual Print (3)

INTRODUCTIONAnova PrecisionTM sous vide circulators are precision temperature controlled circulators designed to regulate the temperature of a water bath.

The system features:

1) Control interface

2) Numeric scroll wheel

3) Removable skirt with directional water pump cap

4) Adjustable ring clamp

6

Page 7: Anova Precision Manual Print (3)

Anova circulators are not designed for direct contact with food. Do not use Anova circulators to directly contact food – at no time should food products also come in contact with bath fl uid. Food must be vacuum-sealed, heat sealed, or zip locked before use with the circulator.

Food products like juice, soup or milk products still need to be bagged or sealed in jars for cooking.

Only the stainless steel skirt and pump cover are dishwasher safe – the heating circulator and display contain sensitive electronics and cannot be placed into the dishwasher.

TECHNICAL SPECIFICATIONS Temperature Min °C Room Temperature (lower with ice bath)

Temperature Max °C 99 ºC

Temperature Stability °C ± 0.01ºC

Heater Power: 800 W Max (120V), 800W Max (220V) Circulation Pump: 8.2 LPM Max

Input Power: USA: 115-120V EU: 220-240V

Wetted Materials: Stainless steel(skirt), Polypropylene(pump cap)

Tip: If you want to have an easier time cleaning the stainless steel parts, use soft/decalcifi ed water to avoid water spots and calcifi cation.

7

Page 8: Anova Precision Manual Print (3)

SETUPAnova sous vide circulators are designed to be used only with water.

8

Page 9: Anova Precision Manual Print (3)

SETUP (clamp & pot)Anova PrecisionTM cooker circulators require a 4.25 inch (11cm) deep container or pot.

1) Place the ring clamp on the side of your container and turn the lower clamp knob until it is tight.

2) Place the circulator into the ring clamp

9

Page 10: Anova Precision Manual Print (3)

SETUP (clamp)

10

3) turn the top system clamp knob until tight.

Page 11: Anova Precision Manual Print (3)

SETUP (pump direction)The pump can channel fl ow around large objects or away from delicate foods.

1) Turn the PrecisionTM cooker in the ring clamp.

or

2) Take off the pump cap, then reinstall with the output pointing to a different direction to change the output direction of the water fl ow.

For extremely delicate foods like eggs or fl ounder - turn the output to the back of the container wall. For large roasts or crowded pots turn the output so the water jet is not blocked by the foods.

Why Change Pump Flow Direction?Precision cooking requires the temperature to be even all the way around the food. For crowded pots or large objects this could mean uneven cooking. For delicate objects like eggs or fi sh the water jet can damage fi llets or crack eggs when “blown” around in the container.

11

Page 12: Anova Precision Manual Print (3)

SETUP (set temp)

Changing Temperature:

1) Turn the scroll wheel up or down

12

Page 13: Anova Precision Manual Print (3)

SETUP (start/stop)

Start/Stop:

1) Press “Play”

13

Page 14: Anova Precision Manual Print (3)

SETUP (change c/f units)

Changing Temperature Units:

1) Hold down the Play/Start button for 3 seconds

14

Page 15: Anova Precision Manual Print (3)

SETUP (Bluetooth)

Enter Pairing Mode:

1) Press “Bluetooth” symbol. Please note if your system is already paired, this action will break pairing

15

Page 16: Anova Precision Manual Print (3)

SETUP (timer)

To display Timer function:

1) Press and hold “Play/Start” for 8 seconds - 2) Press and hold the timer icon for 3 seconds to set time via the scroll wheel. Pressing start or the timer icon again will start the timer countdown

16

Why is the timer function not toggled on from the beginning?

In sous vide cooking temperature is far more important than the time. In fact for most steak dishes going over time multiple hours doesn’t change results as long as you have the correct temperature.

Page 17: Anova Precision Manual Print (3)

SETUP (small pots)For small pots:

1) Place the system in the ring clamp

2) Let the unit rest on the bottom of the pot then tighten the top knob of the ring clamp.

17

Page 18: Anova Precision Manual Print (3)

MaintenanceBEFORE BEGINNING SERVICE:

• Always turn off and unplug the unit.

• Internal service work must be performed by Anova certifi ed personnel only

• Make sure system is at room temperature

Check for signs of damage including pulled cord or physical damage to system or heaters. If any signs of physical damage are found send back for factory ser-vice and replacement parts.

Repairs:If your system falls into the water or is physically damaged, contact Anova Culi-nary LLC for a return authorization number and instructions.

18

Page 19: Anova Precision Manual Print (3)

Maintenance (assembly)Twist the skirt to the left until it comes off.

Sometimes the impellers will get caught on the side of the skirt as the skirt is getting pulled off. Jiggle the skirt from side to side to loosen up the skirt

You can also remove the pump cap fi rst to remove the skirt.

19

Page 20: Anova Precision Manual Print (3)

Maintenance (skirt/pump)Turn the pump cap out of the lock position then pull off.

The skirt and pump cap can be placed into the dishwasher.

20

Page 21: Anova Precision Manual Print (3)

Maintenance (cleaning)

CLEANING THE CIRCULATOR:For cleaning the heating coil, pump shaft, and sensors, use dish soap, a soft tooth brush and rinse under water.

Do not rinse the top part of the circulator including the main body in water.

CLEANING THE SKIRT :To clean the stainless steel skirt and pump cover – place into a dishwasher or wash in the sink with detergent.

21

Page 22: Anova Precision Manual Print (3)

CALCIUM & HARD WATER STAIN REMOVAL:

Hard water stains will appear on the heater and stainless steel skirt. Use the following products to remove stains and lime build up:

1) ZEP Calcium Lime Rust Remover - commercial grade lime remover is a concen-trate and is also the least expensive (by weight). Home Depot and Lowes carry this product. Please be aware this product is very strong and gloves are recommended when handling this material.

2) Lime-Away - this is a home grade lime remover, while not as strong as ZEP, it is car-ried by most grocery stores.

3) Vinegar - while vinegar works to remove lime stains, this option is by far the most expensive and can also smell bad when used in larger amounts.

Maintenance (stains)

22

Page 23: Anova Precision Manual Print (3)

The following Warranty Provisions shall apply to products sold in North America by Anova (“Seller”) to the

entity shown as buyer (“Buyer”) on Seller’s invoice.

1. Initial Warranty. Seller warrants to the Buyer that the products manufactured by the Seller are free from

defects in material and workmanship for a period not to exceed one (1) year or fi ve thousand (5,000) hours

of operation, whichever comes fi rst, from the date the product is shipped by Seller to Buyer (the “Initial

Warranty”).

2. Exclusions. The Initial Warranty does not include damage to the product resulting from accident, misuse,

improper installation or operation, unauthorized or improper repair, replacement or alteration(including

but not limited to repairs, replacements, or alterations made or performed by persons other than Seller’s

employees or authorized representatives), failure to provide improper maintenance, unreasonable use or

abuse of the product, or failure to follow written installation or operating instructions. Water damage and

use of deionized water is not covered on warranty. Buyer must return the product’s record of purchase to

the Seller or one of Seller’s authorized representatives within 365 days of the date the product is shipped by

Seller to Buyer in order to make a claim under the Initial Warranty.

3. Governing Law. The Warranty Provisions and all questions relating to their validity, interpretation, perfor-

mance, and enforcement shall be construed in accordance with, and shall be governed by, the substan-

tive laws of the State of Texas.

4. Shipping. Buyer will arrange and pay for shipping and handling charges for the unit to be returned to the

Seller. Seller will arrange and pay for shipping and handling for the return of the unit to the Buyer.

4. Commercial Usage. This system is not covered under warranty if used in commercial environments.

Warranty Provisions

23

Page 24: Anova Precision Manual Print (3)

Noise: Under normal operation the system will hum due to the motor, impeller and cooling fan in operation.

Grinding noise: The stainless steel skirt is loose. Push the stainless skirt up into the guide groove and turn to the right until you hear a click. With the skirt secure, the noise will go away. There also might be the chance the stirring shaft was inadvertently bent. If this is the case, unscrew the bottom pump disk and gently push the impeller until it is centered.

Slurping noise:Your pump has formed a water vortex like when you are emptying out a bathroom sink or tub. Add more water or gently disturb water with a spoon. There is no sure way to eliminate a vortex from forming due to the pump rotation but usually will go away on its own.

Gurgling + Woosh noise: The pump is sucking air - add more water. You should also see small bubbles in your tank.

Food damage:The pump’s water jet is cracking eggs or damaging fi sh fi llets:Turn the pump outlet to face the container wall; this will greatly temper the fl ow of the pump output. It is also good practice to bag eggs to prevent them from being “blown” around in certain containers.

TroubleShooting FAQ

24

Page 25: Anova Precision Manual Print (3)

System will not turn on:Check power plug and breakers.

Low water level alarm:Add more water – the water level can be dropped during operation by the pump due to water turbulence.

Low water level alarm turns on after a few seconds of operation:Add more water – The pump generates “waves” – sometimes these waves will cause the water level at the sensors to fl uctuate up and down. The waves sometimes drop the water level right under the sensor and will cause a low water alarm. This is nor-mal and you just need to add more water.

Temperature read does not match thermometer:Keep in mind, Anova immersion circulators are calibrated to a scientifi c platinum primary standard which is far more accurate than store thermometers.

Cover your tank with foil and wait about 15 minutes for temperature equilibration – the number one source of temperature read differences is an uncovered tank. If you want your system to match your personal thermometer, use the calibration function provided in the phone application to change the temperature offset.

Lights in house are slightly fl ickering when system is on:This is normal as the circulator is modulating power.

System will not pair:Power circulator off for 10 seconds when power back on. Also the system is designed to pair in APP. Please use the APP to pair the system.

25

Page 26: Anova Precision Manual Print (3)

Anova Culinary LLCHouston, TX USA TEL: 281-980-1236FAX: 281-980-1352www.anovaculinary.com