Anode vessel refractory linings

50
OPTIMIZATION OF REFRACTORY LINING DESIGN AND INSTALLATION PRACTICE TO REDUCE VESSEL DOWNTIME OF ANODE REFINING VESSELS

description

Refractory Linings of Anode vessels

Transcript of Anode vessel refractory linings

Page 1: Anode vessel refractory linings

       

OPTIMIZATION OF REFRACTORY LINING DESIGN AND INSTALLATION PRACTICE TO REDUCE VESSEL DOWNTIME OF

ANODE REFINING VESSELS

Page 2: Anode vessel refractory linings

BLISTER COPPER (>0.6% S) FED TO THEANODE REFINING VESSELS DIRECTLY FROM FLASH/BATH CONVERTING FURNACE(EST. REFRACTORY LINING LIFE 5-6YRS)

ANODE REFINING VESSEL NOW A PRIMARY PRODUCTION UNIT (EST. AVERAGE LINING LIFE ~2 YEARS)

Page 3: Anode vessel refractory linings

THE CONCEPT

• TO DOUBLE THE LIFE OF THE REFRACTORY LINING OF THE ANODE VESSEL(FROM TWO TO FOUR YEARS)

• TO BETTER THAN HALVE THE INSTALLATION TIME OF THE REFRACTORY LINING(FROM 14 to 6 DAYS)

Page 4: Anode vessel refractory linings

OPTIMIZATION OF PERFORMANCE OF THE REFRACTORY LINING

• UTILIZE CORROSION RESISTANT FUSED MAGNESIA-CHROME AROUND TUYERES, SLAG LINE, TAP-OUT SPOUT, SKIMMING AND FEED MOUTH AND IMPACT AREAS

• INSTALL LINING TO THE SHELL (WITH HIGH CONDUCTIVITY GRAPHITE PASTE IF NECESSARY) TO MAXIMIZE HEAT TRANSFER AND LOWER CORROSION RATE

• INSTALL MICROPOROUS INSULATION IN AREAS WHERE BUILD-UP OCCURS

Page 5: Anode vessel refractory linings

OPTIMIZATION OF INSTALLATION TIME REQUIREMENTS

• PROVIDE FOR A BRICK STAGING AREA AT ONE END OF THE VESSEL AND AN ACCESS PORT FORPERSONNEL AND A ROLLER LINE TO SUPPLY BRICK.

• INSTALL BRICK COURSING CONTINUOUSLY USING A SELF-SUPPORTING METHOD

Page 6: Anode vessel refractory linings

OPTIMIZATION OF PROCESS CONTROL

• USE OF POROUS PLUGS TO IMPROVE HEAT TRANSFER,ACCELERATE DESULPHURISATION AND REDUCE SLAG VOLUME.

• INSERT SACRIFICIAL TUYERE TUBE TO REDUCE CONTACT OF COPPER OXIDE WITH REFRACTORY ADJACENT TO TUYERE BRICK.

• USE SEMTECH OPC TO ACCURATELY DETERMINE END POINT OF DESULPHURISATION AND DEOXIDATION

Page 7: Anode vessel refractory linings
Page 8: Anode vessel refractory linings
Page 9: Anode vessel refractory linings
Page 10: Anode vessel refractory linings
Page 11: Anode vessel refractory linings
Page 12: Anode vessel refractory linings

BECANCOUR Production Facility

ANODE REFINING VESSELTUYERE PIPE INSERTION SYSTEM

Page 13: Anode vessel refractory linings
Page 14: Anode vessel refractory linings
Page 15: Anode vessel refractory linings
Page 16: Anode vessel refractory linings
Page 17: Anode vessel refractory linings
Page 18: Anode vessel refractory linings
Page 19: Anode vessel refractory linings
Page 20: Anode vessel refractory linings
Page 21: Anode vessel refractory linings
Page 22: Anode vessel refractory linings
Page 23: Anode vessel refractory linings
Page 24: Anode vessel refractory linings
Page 25: Anode vessel refractory linings
Page 26: Anode vessel refractory linings
Page 27: Anode vessel refractory linings
Page 28: Anode vessel refractory linings
Page 29: Anode vessel refractory linings
Page 30: Anode vessel refractory linings
Page 31: Anode vessel refractory linings
Page 32: Anode vessel refractory linings
Page 33: Anode vessel refractory linings
Page 34: Anode vessel refractory linings
Page 35: Anode vessel refractory linings
Page 36: Anode vessel refractory linings
Page 37: Anode vessel refractory linings
Page 38: Anode vessel refractory linings
Page 39: Anode vessel refractory linings
Page 40: Anode vessel refractory linings
Page 41: Anode vessel refractory linings
Page 42: Anode vessel refractory linings
Page 43: Anode vessel refractory linings
Page 44: Anode vessel refractory linings
Page 45: Anode vessel refractory linings
Page 46: Anode vessel refractory linings
Page 47: Anode vessel refractory linings
Page 48: Anode vessel refractory linings
Page 49: Anode vessel refractory linings

Endwalls 36 hrs Endwalls 36 hrsScaffolding 12 hrsBrick (1/2Half) 48 hrs Brick to T-Plate 36 hrsFormwork 24 hrsBrick Top Half (both 120 hrs Brick to Key 36 hrsRemove Formwork 24 hrs Finishing Key 12 hrs

264 hrs 120 hrs

Traditional(Formwork/Pogo)

Revised(T-Plate/Access Door)

Page 50: Anode vessel refractory linings

CONCLUSIONS

•REFRACTORY ANODE VESSELINTEGRITY DEPENDS ON JUDICIOUS ZONING OF THE HIGHWEAR AREAS

• PRODUCTIVITY CAN BE SEVERELYHAMPERED IF DOWNTIME IS NOTSTRICTLY LIMITED BY RAPID INSTALLATION TECHNIQUES AND THE ABILITY TO PERFORM HOT REPAIRS