and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and...
Transcript of and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and...
![Page 1: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/1.jpg)
Dual frequency comb spectroscopy and atmospheric modeling
for the detection of methane leaks at oil and gas production sites
Sean Coburn1, Caroline Alden1, Robert Wright1, Kevin Cossel2, Garwing Truong2, Esther Baumann2, Subhomoy Ghosh3, Kuldeep Prasad3, Nathan Newbury2, Ian Coddington2, and Greg Rieker1
1Dept. of Mechanical Engineering, University of Colorado, Boulder, CO, USA 2National Institute of Standards and Technology, Boulder, CO , USA
3National Institute of Standards and Technology, Gaithersburg, MD , USA
Coherent Laser Radar Conference 27 June – 1 July 2016
Boulder, CO, USA
1
![Page 2: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/2.jpg)
Outline
Background
Coupled measurement/inversion regional monitoring solution
Dual-frequency comb spectroscopy
Large Eddy simulations/Atmospheric Inversion
Synthetic data tests
Test site configuration
Outlook
2
![Page 3: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/3.jpg)
Background
Atmospheric methane (CH4)
Potent greenhouse gas
• 25x > CO2 (100 yrs)
Natural and anthropogenic sources
• Landfills, agriculture, wastewater treatment, oil and gas systems, coal mining
• Sink: oxidation by OH Accounts for 11% of all US GHG emissions
• >50% from anthropogenic sources
• 25% from natural gas systems
US Greenhouse Gas Inventory Report: 1990-2014, US EPA, April 2016 3
![Page 4: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/4.jpg)
Background
Rapid growth in US natural gas production since 2007 • EPA released new rules for
regulating CH4 from oil and natural gas production systems (May 2016)
ARPA-E MONITOR Program Develop new technology/techniques for sensing methane at oil and natural gas production sites
• Capable of determining size and location of methane leaks • Competitive cost compared with current methods • Provide efficient end user (industry) platform
4
![Page 5: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/5.jpg)
Natural gas extraction east of
Platteville Colorado. DCS could
monitor over 100 sites from a
central location. Overlapping
fields could ensure complete
coverage.
Potential deployment configurations
Retro
UAV
plume
plume
Spectrometer
Spectrometer
Coupled Regional Monitoring Solution
Centralized spectrometer
5
![Page 6: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/6.jpg)
Natural gas extraction east of
Platteville Colorado. DCS could
monitor over 100 sites from a
central location. Overlapping
fields could ensure complete
coverage.
Potential deployment configurations
Retro
UAV
plume
plume
Spectrometer
Spectrometer
Coupled Regional Monitoring Solution
Centralized spectrometer
Retroreflector array
6
![Page 7: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/7.jpg)
Natural gas extraction east of
Platteville Colorado. DCS could
monitor over 100 sites from a
central location. Overlapping
fields could ensure complete
coverage.
Potential deployment configurations
Retro
UAV
plume
plume
Spectrometer
Spectrometer
Coupled Regional Monitoring Solution
Centralized spectrometer
Retroreflector array
Couple measurements to transport simulation and inversion
Locate and size CH4 leaks
7
![Page 8: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/8.jpg)
Methane measurements
Dual frequency comb spectrometry • High precision • Robust • Proven over kilometer scale open paths (Rieker et al., 2014, Optica)
8
![Page 9: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/9.jpg)
Passively
Modelocked Laser
Methane measurements
T=1 / frep
A Frequency Comb = Stabilized Mode-Locked Laser
Dual frequency comb spectrometry • High precision • Robust • Proven over kilometer scale open paths (Rieker et al., 2014, Optica)
9
![Page 10: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/10.jpg)
Methane measurements
A Frequency Comb = Stabilized Mode-Locked Laser
I( f )
0
fo
>100,000 lasers
Dual frequency comb spectrometry • High precision • Robust • Proven over kilometer scale open paths (Rieker et al., 2014, Optica)
10
![Page 11: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/11.jpg)
Methane measurements
A Frequency Comb = Stabilized Mode-Locked Laser
Stabilize two degrees-of-freedom -> entire comb is stabilized
I( f )
0
fo
Phase-lock (stabilize) offset frequency, fo
Phase-lock (stabilize) one tooth
to a reference laser
>100,000 well behaved lasers
fn = nfrep+ f0
Dual frequency comb spectrometry • High precision • Robust • Proven over kilometer scale open paths (Rieker et al., 2014, Optica)
11
![Page 12: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/12.jpg)
Coherent Dual-Comb Spectroscopy
Detector Frequency Comb 1
Frequency Comb 2
gas
absorption profile
Open path Interfere signals from two coherently locked combs
12
![Page 13: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/13.jpg)
Coherent Dual-Comb Spectroscopy
Detector Frequency Comb 1
Frequency Comb 2
gas
absorption profile
Open path Interfere signals from two coherently locked combs
RF frequencies
13
![Page 14: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/14.jpg)
RF
Po
we
r
17.4178517.41780RF Frequency (MHz)
2 kHz (2×10-8 nm) Comb tooth linewidth: 2×10-8 nm Wavelength accuracy: 1×10-6 nm R
F P
ow
er
Coherent Dual-Comb Spectroscopy
Detector Frequency Comb 1
Frequency Comb 2
gas
absorption profile
Optical Frequency (THz) 180ish 180ish
Open path
Portable DCS
14
![Page 15: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/15.jpg)
Coherent Dual-Comb Spectroscopy
Detector Frequency Comb 1
Frequency Comb 2
gas
absorption profile
Open path
Comb tooth spacing: ~0.002 nm
RF
Po
we
r
200 MHz (0.002 nm)
Optical Frequency
Portable DCS
15
![Page 16: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/16.jpg)
Detector Frequency Comb 1
Frequency Comb 2
gas
absorption profile
105 nm wavelength span, 0.002 nm point spacing 100s of absorption lines - CH4, CO2, H2O 650 𝛍s acquisition time per
spectrum - 7000 averages to reach
SNR at right
Tran
smis
sio
n
Optical Frequency
Open path
CH4
H2O
CO2
Coherent Dual-Comb Spectroscopy
Portable DCS
16
![Page 17: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/17.jpg)
Detector Frequency Comb 1
Frequency Comb 2
gas
absorption profile
105 nm wavelength span, 0.002 nm point spacing 100s of absorption lines - CH4, CO2, H2O 650 𝛍s acquisition time per
spectrum - 7000 averages to reach
SNR at right
Tran
smis
sio
n
Optical Frequency
Fit to retrieve integrated concentration of trace gases along light path
Open path
Coherent Dual-Comb Spectroscopy
Portable DCS
17
![Page 18: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/18.jpg)
CH4& H
2O features
(+ weak CO2)
CO2 features
(+ weak H2O, HDO,
hotbands)
Ab
so
rba
nce
610060806060
d
Wavenumbers (cm-1)624062206200
-4
4
Re
sid
ua
l
(x1
0-3)
1650 1645 1640Wavelength (nm)
1615 1610 1605 1600
0.1
0.0
440
400
CO
2,dry
(ppm
)
2.0
1.9CH
4,dry
(ppm
)
30
10Te
mp
.
(C)
1.0
0.5
12:00 12:00 12:0024:00 24:00 24:00
H2O
(%
)
1 day
e
Proof of concept measurements
18
![Page 19: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/19.jpg)
• 3 ppb CH4 sensitivity in 5 minutes over 2 km
2.0
1.9CH
4, d
ry
(pp
m)
12:00 AM6/1/2013
12:00 PM 12:00 AM6/2/2013
12:00 PM 12:00 AM6/3/2013
12:00 PM
440
420
400CO
2, d
ry
(pp
m)
1.0
0.5H2O
(%)
30
20
10
Te
mp
. (
ºC)
4
2
0
HD
O(p
pm
)1 day
Proof of concept measurements
19
![Page 20: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/20.jpg)
Methane precision: portable DCS vs POC
POC: 4ppb*km in 1000s
20
![Page 21: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/21.jpg)
Methane precision: portable DCS vs POC
POC: 4ppb*km in 1000s Portable: 1-4ppb*km in 100s 21
![Page 22: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/22.jpg)
Methane precision: portable DCS vs POC
POC: 4ppb*km in 1000s Portable: 1-4ppb*km in 100s
Limited by atmospheric variability (not instrument) 22
![Page 23: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/23.jpg)
High resolution simulation of atmospheric transport • Software developed and maintained by the Engineering Laboratory at NIST
• Scalable, large-scale parallel computations • Import wind speed / direction and meteorological parameter • Import topography
Large Eddy Simulation
LES
• Meteorological data from local station • One minute temporal resolution • 8 meter spatial resolution
Spectrometer
Fixed laser beam paths 500 m
Low to moderate Wind Conditions High Wind Conditions
23
![Page 24: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/24.jpg)
Monitoring Solution Framework
24
![Page 25: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/25.jpg)
Measurements from BAO during FRAPPE 2014 • Meteorological • CH4 (for
background)
Synthetic data testing
25
![Page 26: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/26.jpg)
Measurements from BAO during FRAPPE 2014 • Meteorological • CH4 (for
background)
Synthetic data testing
Synthetic
26
![Page 27: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/27.jpg)
Synthetic
Synthetic data testing
Measurements from BAO during FRAPPE 2014 • Meteorological • CH4 (for
background)
27
![Page 28: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/28.jpg)
Synthetic data testing
✳ Spectrometer • Wells in domain • TRUE leak
Initial test configuration • 1km x 1km domain • 1 “true” leak • 4-8 possible leaks
28
![Page 29: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/29.jpg)
Synthetic data testing
✳ Spectrometer • Wells in domain • TRUE leak
Initial test configuration • 1km x 1km domain • 1 “true” leak • 4-8 possible leaks
ARPA-E target leak rate = 6 scfh (~3.5x10-5 kg s-1)
29
![Page 30: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/30.jpg)
Synthetic data testing
✳ Spectrometer • Wells in domain • TRUE leak • Solution ± 2-stdv
✳ Spectrometer • Wells in domain • TRUE leak
Initial test configuration • 1km x 1km domain • 1 “true” leak • 4-8 possible leaks
30
![Page 31: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/31.jpg)
BAO Tower BAO site access
Nearby wells (from Colorado Oil & Gas Conservation Commission) 1
mile
1 mile
Test site configuration
31
![Page 32: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/32.jpg)
Synthetic data testing (for BAO test site)
• “TRUE” LEAKS
So
urc
e S
tre
ng
th (
kg
/s)
Realistic test configuration • 2km x 2km domain • 2 “true” leaks • 52 wells (possible leaks)
32
![Page 33: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/33.jpg)
• “TRUE” LEAKS • SOLUTION MEAN ± 2*STDV
So
urc
e S
tre
ng
th (
kg
/s)
Synthetic data testing (for BAO test site)
Realistic test configuration • 2km x 2km domain • 2 “true” leaks • 52 wells (possible leaks)
33
![Page 34: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/34.jpg)
BAO Tower BAO site access
Nearby wells (from Colorado Oil & Gas Conservation Commission) 1
mile
1 mile
Test site configuration
34
![Page 35: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/35.jpg)
BAO Tower BAO site access
Nearby wells (from Colorado Oil & Gas Conservation Commission) 1
mile
1 mile
Test site configuration
Mobile lab location
35
![Page 36: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/36.jpg)
Test site configuration
N
S
BAO ideally suited for remote CH4 sensing • Many other research studies have taken
place here • Current trace gas sampling
• Offers a realistic background for oil and gas production sites
• Good for testing inversion modeling
36
![Page 37: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/37.jpg)
Summary/Outlook
Built and tested a portable dual frequency comb spectrometer for measuring methane over kilometer scale open paths
Built out inversions to couple LES and line of sight DCS measurements
Demonstrated success in locating 1 and 2 leaks within the test domain
• Synthetic data runs
• Modeling domain actually larger than test site (included 52 active wells)
Infrastructure in place to start field testing dual-frequency comb
Begin coupling actual measurements into model
Start exploring other potential field test sites
• Cover different terrain, background CH4, etc. 37
![Page 38: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/38.jpg)
Funding
ARPA-E MONITOR program (DE-AR0000539)
Support
NIST Boulder/Gaithersburg
Rieker Research Group
BAO site managers
Acknowledgements
38
![Page 39: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/39.jpg)
Synthetic data tests use point source CH4 measurements from 2014 as background, along with the winds that accompanied those measurements
Inversions consistently find signal south-east of BAO…
Synthetic data testing (for BAO test site)
39
![Page 40: and atmospheric modeling for the detection of methane ... · Dual frequency comb spectroscopy and atmospheric modeling for the detection of methane leaks at oil and gas production](https://reader030.fdocuments.in/reader030/viewer/2022040921/5e9a1c025932a525806693a7/html5/thumbnails/40.jpg)
‣ Leak strength of 1.5E-3 kg/s
‣ Divided by 3.9E-6 kg/s per cow (McGinn and Beauchemin, 2012)
‣ Estimated 390 ± 120 head cattle at Hulstrom
So
urc
e S
tren
gth
(kg/s
) ‣ Dairy farm with 400 head of cattle
produces a ‘leak’ that is 50x greater than the MONITOR 6 scfh target
Synthetic data testing (for BAO test site)
40