Analytical Assessment Technology Advancements &...

16
Analytical Assessment Technology Advancements & Common Analytical Pitfalls Mike Ericson Laboratory Director Con-Test Analytical Laboratory

Transcript of Analytical Assessment Technology Advancements &...

Page 1: Analytical Assessment Technology Advancements & …s3.amazonaws.com/ebcne-web-content/fileadmin/pres/...Technology Advancements & Common Analytical Pitfalls Mike Ericson Laboratory

Analytical Assessment Technology Advancements & Common Analytical Pitfalls

Mike Ericson

Laboratory Director Con-Test Analytical Laboratory

Page 2: Analytical Assessment Technology Advancements & …s3.amazonaws.com/ebcne-web-content/fileadmin/pres/...Technology Advancements & Common Analytical Pitfalls Mike Ericson Laboratory

Analytical Assessment Technology Advancements and Common Analytical Pitfalls

Michael Erickson

Page 3: Analytical Assessment Technology Advancements & …s3.amazonaws.com/ebcne-web-content/fileadmin/pres/...Technology Advancements & Common Analytical Pitfalls Mike Ericson Laboratory

PCB Structure

Page 4: Analytical Assessment Technology Advancements & …s3.amazonaws.com/ebcne-web-content/fileadmin/pres/...Technology Advancements & Common Analytical Pitfalls Mike Ericson Laboratory

Aroclor 1242

PCB 18

• Aroclors are comprised of varying ratios of the 209 PCB congeners

• Aroclor mixtures are characterized by the amount of chlorine they contain (i.e. 1242 contains 42% chlorine)

Page 5: Analytical Assessment Technology Advancements & …s3.amazonaws.com/ebcne-web-content/fileadmin/pres/...Technology Advancements & Common Analytical Pitfalls Mike Ericson Laboratory

IUPAC # Compounds Isomer Class Homologues 1 2-Chlorobiphenyl 1 Cl 2 3-Chlorobiphenyl 1 Cl Monochlorobiphenyl 3 4-Chlorobiphenyl 1 Cl 4 2,2'-Dichlorobiphenyl 2 Cl 5 2,3-Dichlorobiphenyl 2 Cl 6 2,3'-Dichlorobiphenyl 2 Cl 7 2,4-Dichlorobiphenyl 2 Cl 8 2,4'-Dichlorobiphenyl 2 Cl 9 2,5-Dichlorobiphenyl 2 Cl

10 2,6-Dichlorobiphenyl 2 Cl Dichlorobiphenyl 11 3,3'-Dichlorobiphenyl 2 Cl 12 3,4-Dichlorobiphenyl 2 Cl 13 3,4'-Dichlorobiphenyl 2 Cl 14 3,5-Dichlorobiphenyl 2 Cl 15 4,4'-Dichlorobiphenyl 2 Cl 16 2,2',3-Trichlorobiphenyl 3 Cl Trichlorobiphenyl . . . . . . . . . . . .

206 2,2',3,3',4,4',5,5',6-Nonachlorobiphenyl 9 Cl 207 2,2',3,3',4,4',5,6,6'-Nonachlorobiphenyl 9 Cl Nonachlorobiphenyl 208 2,2',3,3',4,5,5',6,6'-Nonachlorobiphenyl 9 Cl 209 2,2',3,3',4,4',5,5',6,6'-Decachlorobiphenyl 10 Cl Decachlorobiphenyl

PCB Homologues

Page 6: Analytical Assessment Technology Advancements & …s3.amazonaws.com/ebcne-web-content/fileadmin/pres/...Technology Advancements & Common Analytical Pitfalls Mike Ericson Laboratory

Dioxin-like Compounds

Similar geometry (planar) and chlorine substitution pattern

Of the 209 congeners 12 are dioxin-like

Three most toxic congeners include PCB 77, 126 & 169 (non-ortho substitution)

Tetrachlorodioxin PCB 77 PCB 54

Page 7: Analytical Assessment Technology Advancements & …s3.amazonaws.com/ebcne-web-content/fileadmin/pres/...Technology Advancements & Common Analytical Pitfalls Mike Ericson Laboratory

PCB Extraction Methods

Solids

SW-846 3540C Soxhlet Extraction (TSCA, Region 1)

SW-846 3550C Ultrasonic Extraction

SW-846 3545A Pressurized Fluid Extraction (PFE)

SW-846 3546 Microwave Extraction

Liquids

SW-846 3510C Liquid-Liquid Extraction

SW-846 3535 Solid Phase Extraction

Page 8: Analytical Assessment Technology Advancements & …s3.amazonaws.com/ebcne-web-content/fileadmin/pres/...Technology Advancements & Common Analytical Pitfalls Mike Ericson Laboratory

SW-846 3540C Soxhlet Extraction

Page 9: Analytical Assessment Technology Advancements & …s3.amazonaws.com/ebcne-web-content/fileadmin/pres/...Technology Advancements & Common Analytical Pitfalls Mike Ericson Laboratory

Analytical Methods

SW-846 8000C

SW-846 8082

Water, Soil, Sediment

Wipes, Paint, Caulking

TO-10A, TO-4

Air – PUF

EPA 680

Homologues

SW-846 8270 Modified

Congeners

Page 10: Analytical Assessment Technology Advancements & …s3.amazonaws.com/ebcne-web-content/fileadmin/pres/...Technology Advancements & Common Analytical Pitfalls Mike Ericson Laboratory

Extract Clean-up Methods

SW-846 3665A Sulfuric Acid Clean-up Elevated baselines

Complex chromatograms

SW-846 3660B Sulfur Clean-up Elemental Sulfur in many sediments

Solubility is similar to PCBs

SW-846 3620C Florisil Cartridge Clean-up Polar hydrocarbons

Other polar material

Enhanced column Clean-up Primarily for troublesome caulking

Page 11: Analytical Assessment Technology Advancements & …s3.amazonaws.com/ebcne-web-content/fileadmin/pres/...Technology Advancements & Common Analytical Pitfalls Mike Ericson Laboratory

Aroclor 1242 “under” sulfur peak

Page 12: Analytical Assessment Technology Advancements & …s3.amazonaws.com/ebcne-web-content/fileadmin/pres/...Technology Advancements & Common Analytical Pitfalls Mike Ericson Laboratory

Aroclor 1242 with Sulfur Interference Removed

Page 13: Analytical Assessment Technology Advancements & …s3.amazonaws.com/ebcne-web-content/fileadmin/pres/...Technology Advancements & Common Analytical Pitfalls Mike Ericson Laboratory

Enhanced Clean-up with Interference Removed

Page 14: Analytical Assessment Technology Advancements & …s3.amazonaws.com/ebcne-web-content/fileadmin/pres/...Technology Advancements & Common Analytical Pitfalls Mike Ericson Laboratory

PCB’s in Air Sampling

Polychlorinated biphenyls are sampled on a PUF (polyurethane foam) cartridge. High volume samples are taken on large high volume PUF’s by EPA Method TO-4A. Low volume samples can be taken by EPA Method TO-10A.

HIGH VOLUME

LOW VOLUME

Page 15: Analytical Assessment Technology Advancements & …s3.amazonaws.com/ebcne-web-content/fileadmin/pres/...Technology Advancements & Common Analytical Pitfalls Mike Ericson Laboratory

PCB’s in Caulking, Air, Wipes…

Typical Reporting Limits

PCB Aroclors in Air*

TO-4A (High Volume) 0.062-0.62 ng/m3

TO-10A (Low Volume) 0.0028-0.83 ug/m3

Optional

NIOSH 5503* 0.069-2.0 ug/m3

* RL calculated from sample volume

PCB 8082 in caulking/paint <1 mg/Kg 0.5/0.2g

PCB 8082 in concrete/brick 0.5 mg/Kg 2g

PCB 8082 in soil 0.1 mg/Kg 10g

PCB 8082 wipes 0.2ug/wipe 1 wipe

PCB 680 Homologues in wipes/air 0.001-0.005µg/homolog

25ng total PCB’s

Page 16: Analytical Assessment Technology Advancements & …s3.amazonaws.com/ebcne-web-content/fileadmin/pres/...Technology Advancements & Common Analytical Pitfalls Mike Ericson Laboratory

Thank you

Any Questions?

Michael Erickson [email protected] 413-525-2332