ANALISE VIBRAÇÃO

6
3 April 1997 A Demo Vibration report on Various Items EFFTEK Diagnostic Engineers Business & Innovation Centre Wearfield SUNDERLAND Tyne & Wear SR5 2TA Tel (0191) 5166378 Email [email protected] Vibration Analysis

description

Exemplo de análise de vibração

Transcript of ANALISE VIBRAÇÃO

  • 3 April 1997

    A Demo Vibration report onVarious Items

    EFFTEKDiagnostic Engineers

    Business & Innovation CentreWearfield

    SUNDERLANDTyne & Wear

    SR5 2TA

    Tel (0191) 5166378

    [email protected]

    VibrationAnalysis

  • Machines Monitored List

    Machine Condition Remarks

    No. 1 Paint Pump O.K.

    No. 2 Paint Pump CAUTION See text

    After Rinse Pump ACTION Defective motor de bearing

    Boiler Forced Draft Fan. O.K.

    Vibration Analysis Report3 April 1997

  • After Rinse Pump

    Plot 1 shows the enveloped spectras from the motor bearings of this unit.

    As can be seen, the spectra from point 1 shows a much higher level of activity with peaksabove the alarm limit of 0.5 G's. The spectra shows multiple harmonics of approximately 20Hz. which is a bearing cage frequency.

    The amplitude and characteristics of the spectra suggest that the bearing is in an advancedstage of deterioration and it is recommended that the motor should be removed andoverhauled as soon as possible.

    Vibration Analysis Report3 April 1997

  • .Plot 1

    Vibration Analysis Report3 April 1997

  • No. 2 Paint Pump

    Plot 2 shows the enveloped spectras from both motor bearings of this unit.

    These are examples of healthy spectras and are included for comparison to those shown forthe After Rinse Pump. There is evidence of slight bearing activity shown by the peaks abovethe 'carpet' level, however, these are at insignificant levels.

    At this time no action is required, however, it is recommended that caution should be observeduntil the next survey is carried out.

    Vibration Analysis Report3 April 1997

  • Plot 2

    Vibration Analysis Report3 April 1997