AN ELECTRO-TECHNICAL TESTING LABORATORYAt present, the demand for power has increased many folds and so is the expectation of customers. All customers want reliable power. This has created need for technologically advanced infrastructure solutions to minimize the electrical losses, minimize the breakdowns, assure public safety and avoid any potential liability.
Cables, Conductors and transformers serve as most important assets of the Power System for Transmission and Distribution of Electrical Energy from generation points to the end users.
It is observed that Cables, Conductors and transformers manufacturing industries are implementing the latest technologies and resources. Power Distribution Companies are adopting various techniques to assure the quality of the power to meet the speci�c requirements of their customers,
Rajasthan Test and Research Centre (RTRC) performs testing of Cables, Conductors and transformers in accordance with various National and International Standards i.e. IS/ISO/IEC/BS/BSEN/ASTM/ NEMA/ANSI/SANS/NES/NFC/etc.
RTRC Tests all the products/accessories with the objective to check and analyze their performance through a series of rigorous tests to identify and detect potential defects, which might otherwise jeopardize reliable operation.
Rajasthan Test & Research Centre (RTRC) is housed in most modern building having covered area 1800 sq. ft. and is situated in the heart of Manesar Gurugram which is an Industrial Hub in northern India.
RTRC is an Electro-technical Testing laboratory complying with the requirements of IS/ISO/IEC 17025:2017 – latest standard for “General Requirements for the Competence of Testing Laboratories” and is accredited with the National Accreditation Board for Testing and Calibration Laboratories (NABL).
A constituent Board of Quality Council of India. NABL is a full member of the International Laboratory Accreditation Cooperation (ILAC) and Asia Paci�c Accreditation Co-operation (APAC). NABL is signatory to ILAC as well as APAC Mutual Recognition arrangement (MRA) for accreditation of Testing and Calibration Laboratory, thus the Test Reports issued by us are accepted Worldwide amongst all member countries of International Laboratory Accreditation Cooperation (ILAC) and Asia Paci�c Accreditation Cooperation (APAC)
RTRC is recognized by the Bureau of Indian Standards (BIS), working under the aegis of Ministry of Consumer A�airs, Food & Public Distribution, and Government of India. RTRC is one of the three Laboratories in India recognized by BIS for performing testing of HT Cables. Detailed information is available on the BIS Website.
RTRC started its journey in the year 2008 by getting the accreditation in accordance with ISO/IEC 17025:2005. At present, we are equipped with state-of-the-art testing facilities covered in 18000 sq. ft. area.
Our people are fully competent & we enjoy a leadership position in all segments we cater to. We are always innovative & dynamic.
RTRC is proud of its competence in testing of Cables. We have a team of professionally quali�ed and experienced personnel. We use technologically advanced equipment, having high accuracy and precision.
The team of testing personnel are having experience and expertise in the �eld of high voltage and other tests like UV, Thermal Endurance, Toxicity Index, Presence of Fluorine content, test for Circuit Integrity for cables under speci�ed conditions and other tests.
RTRC believes that they are one of the best in the World for testing and evaluation of Cables for independent, unbiased and reliable services. All the personnel are trained and possess expertise for interpreting test results and even help to improve and enhance design capabilities of the manufacturer.
RTRC caters to the testing requirements of global customers like TUV Rheinland, Belden (U.S.), TACS Laboratory (South Africa), etc.
• Central Public Works Department (CPWD),• National Buildings Construction Corporation Limited (NBCC), • Airports Authority of India (AAI), • Department of Atomic Energy (DAE), • Indian Space Research Organization (ISRO) and many more.
A JOURNEY TOWARDSEXCELLENCE
RTRC is competent to do testing of the following cables, Wires & Conductors and Transformers:
• Energy (Power) Cables up to 66 kVE
• Cables up to 66 kVE covering all types of insulating & sheathing material
• Aerial Bunched/Bundled Cables
• Elastomeric Insulated Cables
• FR/FR-LSH/LSZH/ZHFR/HFFR Cables
• Fire Alarm Cables & Circuit Integrity Cables (Also known as Fire Survival Cables)
• Mining Cables
• Solar Cables
• Instrumentation Cables
• Thermocouple Compensating Cables
• Welding Cables
• Winding Wires for Submersible Cables
• Cables for Motor Vehicles
• Flexible Cables for lifts & other �exible connections
• Overhead Conductors
• Raw Materials for Cables & Conductors
• Outdoor/ Indoor Oil-immersed/ Dry-type Power/ Distribution Transformers Up to 2.5 MVA 33 KVE
COMPETENCY
CIRCUIT INTEGRITY CABLES AS PER IEC AND BS STANDARDS
SPECIAL TESTS AS PER INTERNATIONAL & NATIONAL STANDARDS
ISO 4892-2BS EN 50289-4-17 Ultraviolet (UV) Test (Xenon Arc Lamp)UL 1581 Section-1200ASTM G 155
ASTM G 154 Ultraviolet (UV) Test (Fluorescent Lamp)
NES 713NCD 1409 Toxicity Index Test
NEMA WC-53NEMA WC-70ASTM D 2633-02IEC 60502-1 Accelerated Water Absorption TestIEC 60502- 2 (Electrical Method)IS 10810 (Part-28)IEC 60840
NEMA WC-57ASTM D 2633-02 Dielectric Strength Retention
BS EN 50618BS EN 60216-1 Thermal EnduranceBS EN 60216-2
IS 10810 (Part-19) Bleeding and Blooming
IEC 60811 (Part-404)IS 10810 (Part-31) Oil Resistance
IS 2465 E�ect of Lubricating oil, Break �uid, Diesel, Petrol
ASTM D 2843IS 13360 (Part-6/Sec-9) Smoke Density Rating
IEC 61034-2BS EN 61034-2IS 10810 (Part-63) Measurement of Smoke Density
ISO 4589-2ASTM D 2863 Oxygen Index IS 10810 (Part-58)
ISO 4589-3IS 10810 (Part-64) Temperature Index
IEC 60332 Test for vertical �ame spread ofIEEE 383 vertically mounted bunchedIS 10810 (Part-62) wires or cables
IEC 60754-1IS 10810 (Part-59) Halogen Acid Gas Evolution
IEC 60754-2IS 17048 pH & Conductivity
SS-424-1475 IS 10810 (Part-61) Swedish Chimney (Flame Retardant)
Airports Authorityof India Speci�cation Anti-Rodent & Termite
IEC 60684-2BS EN 50525-1 Presence of Fluorine andIS 17048 Fluorine Content
IEC 62930 Dynamic penetration
BS 7629-1 Fire resistant, screened, �xed installation multicore cables
BS 7846 Thermosetting insulated, armoured, Fire Resistant Cables
BS 6387 (Protocol C)IEC 60331-11IEC 60331-21IEC 60331-23 IEC 60331-25 Resistance to Fire Alone IS 16246
BS 6387 (Protocol W) Resistance to Fire with Water
BS 6387 (Protocol Z)IEC 60331-2 (less than 20mm diameter) Resistance to Fire with Mechanical Shock
IEC 60331-1 (more than 20mm diameter) Assessment of �re circuit integrity mechanical shock
BS 8491 Assessment of �re integrity with mechanical shock and water (Category F30, F60,120)
BS 8434-2 Resistance to Fire with Mechanical Shock & WaterBS EN 50200 (Classi�cation PH 15,30,60,90,120)
IEC60331-3BS EN 60331-3 Circuit Integrity Test under Fire Conditions in metal enclosure
COMPETENCY
IS 7098 (Part 1) Cross Linked Polyethylene Insulated Thermoplastic Sheathed cables for working voltages upto and including 1100V
IS 7098 (Part 2) Cross Linked Polyethylene Insulated Thermoplastic Sheathed cables for working voltages from 3.3 kV upto and including 33 kV
IS 7098 (Part 3) Cross Linked Polyethylene Insulated Thermoplastic Sheathed cables for working voltages from 66 kV upto and including 220 kV
IS 8783 (Part 4 Sec 1) Winding Wires for Submersible Motors – Part 4 - Speci�cation for Individual Wires Section 1 - HR PVC Insulated Wires
IS 8783 (Part 4 Sec 2) Winding Wires for submersible motors – Part 4 - Speci�cation for individual wires Section 2 - Cross linked Polyethylene Insulated and Polyamide Jacketed Wires
IS 8783 (Part 4 Sec 3) Winding Wires for Submersible Motors – Part 4 - Speci�cation for Individual Wires Section 3 - Polyester and Polypropylene Insulated Winding Wires
IS 8784 Thermo-couple Compensating cables
IS 9857 Welding Cables
IS 9968 (Part 1) Elastomer Insulated Cables for working voltages upto and including 1100V
IS 9968 (Part 2) Elastomer Insulated Cables for working voltages from 3.3 kV to 33 kV
IS 10810 Method of test for cables
IS 3360 (Part 6 Sec 9) Plastics- Methods of testing – Part 6: Thermal Properties Section 9: Determination of Density of Smoke from the Burning or Decomposition of Plastics
IS 14255 Aerial Bunched Cables for working voltages upto and including 1100V
IS 14494 Elastomer Insulated Flexible Cables used in Mines
IS 17048 Halogen Free Flame Retardant (HFFR) cables for working voltages upto and including 1100 Volts
IS 16246 Elastomer Insulated Cables with limited circuit integrity when a�ected by �re.
COMPLETE TESTING FACILITIES AS PER NATIONAL STANDARDS FORCABLES AND CONDUCTORSIS 191 Copper – Speci�cation
IS 398 (Part 1) Aluminium Conductors for Overhead Transmission Purposes.
IS 398 (Part 2) Aluminium Conductors for Overhead Transmission Purposes - Aluminium Conductors, galvanized steel-reinforced
IS 398 (Part 3) Aluminium Conductors for overhead transmission purpose (Aluminium Conductors, Aluminized Steel Reinforced)
IS 398 (Part 4) Aluminium Conductors for overhead transmission purpose (Aluminium Alloy Stranded Conductors)[Al. – Magnesium – Silicon Type]
IS 398 (Part 5) Aluminium Conductors – Galvanized Steel – Reinforced for extra high voltage (400 kV & above)
IS 440 Methods of Chemical Analysis of Copper
IS 694 Polyvinyl Chloride Insulated unsheathed and sheathed cables/cords with rigid and �exible conductor for rated voltages upto and including 1100 V
IS 1554 (Part 1) PVC Insulated (Heavy Duty) Electric cables for working voltages upto 1100 V
IS 1554 (Part 2) PVC Insulated (Heavy Duty) Electric cables for working voltages from 3.3 kV upto and including11 kV
IS 2530 Methods of Test for Polyethylene Moulding Materials and Polyethylene Compounds
IS 2465 Cables for Motor Vehicle
IS 3975 Mild steel wires, formed wires and tapes for armouring of cables
IS 4289 (Part 1) Flexible Cables for Lifts and other �exible Connection (Part 1 Elastomer Insulated Cable)
IS 4289 (Part 2) Flexible Cables for Lifts and other �exible Connection (Part 2 PVC Insulated Circular Cable)
IS 5831 PVC insulation and sheath of electric cables
IS 6380 Elastomeric Insulation and Sheath of Electric Cables
INNOVATION
COMPLETE TESTING FACILITIES AS PER IEC STANDARDS FOR CABLES
IEC 60227-1 Polyvinyl Chloride Insulated Cable for rated voltages upto 450/750V - Part 1: General requirements
IEC 60227-2 Polyvinyl Chloride Insulated Cables for rated voltages upto 450/750V- Part 2: Test methods
IEC 60227-3 Polyvinyl Chloride Insulated Cables Part 3: Non-sheathed cables for �xed wiring
IEC 60227-4 Polyvinyl Chloride Insulated Cables Part 4: Sheathed Cables for Fixed Wiring
IEC 60227-5 Polyvinyl Chloride Insulated Cables Part 5: Flexible cables (Cords)
IEC 60227-6 Polyvinyl Chloride Insulated Cables Part 6: Lift Cables and cables for �exible connections
IEC 60228 Conductors of insulated cables
IEC 60245-1 Rubber insulated cables - Part 1 – General requirements
IEC 60245-2 Rubber insulated cables - Part 2 – Test methods
IEC 60245-3 Rubber insulated cables - Part 3 - Heat resistant silicone insulated cables
IEC 60245-4 Rubber insulated cables - Part 4 - Cords and Flexible Cables
IEC 60245-5 Rubber insulated cables - Part 5 - Lift Cables
IEC 60331-1 Test method for �re with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0.6/1.0 kV and with an overall diameter exceeding 20 mm
IEC 60331-2 Test Method for �re with shock at a temperature of at least 830OC for cables of rated voltages upto & including 0.6/1.0 kV and with an overall diameter not exceeding 20 mm
IEC 60331-3 Test Method for �re with shock at a temperature of at least 830 °C
IEC 60331-11 Tests for electric cables under �re conditions – Circuit Integrity – Part-11: Apparatus – Fire alone at a �ame temperature of at least 750 °C
IEC 60331-21 Fire Alone at a Flame Temperature of at least 750 deg. C
IEC 60331-25 Test for electric cables under �re conditions- Circuit Integrity Procedure and requirements – Optical Fibre Cables
IEC 60332-21 Test for vertical �ame spread of vertically-mounted bunched wires or cables - Category A F/R
IEC 60332-22 Test for vertical �ame spread of vertically-mounted bunched wires or cables - Category A
IEC 60332-23 Test for vertical �ame spread of vertically-mounted bunched wires or cables - Category B
IEC 60332-24 Test for vertical �ame spread of vertically-mounted bunched wires or cables - Category C
IEC 60332-25 Test for vertical �ame spread of vertically-mounted bunched wires or cables - Category D
IEC 60502-1 Power Cables with extruded insulation and their accessories for rated voltages from 1kV to 3 kV
IEC 60502-2 Power Cables with extruded insulation and their accessories for rated voltages from 6kV to 30 kV
IEC 60811 Electric and optical �bre cables- Test methods for non-metallic materials
IEC 60840 Power cables with extruded insulation and their accessories for rated voltages above 30kV (Um = 36 kV) up to 150 kV (Um= 170 kV) - Test methods and requirements
IEC 62930 Electrical Cables for photovoltaic system
IEC/BS EN 61034-2 Measurement of smoke density of cables burning under de�ned conditions
TECHNICALEXPERTISE
COMPLETE TESTING FACILITIES AS PER BS AND BS EN STANDARDS FOR CABLES & CONDUCTORSBS 5467 Thermosetting insulated, armoured cables for
voltages of 600/1000V and 1900/3300V for �xed installations
BS 6004 PVC Insulated and PVC Sheathed cables for electric power and lighting
BS 6195 Rubber or Silicon Rubber insulated �exible cables & cords for coils & leads
BS 6231 Single core PVC insulated �exible cable for switchgear and control gear wiring
BS 6387 Test method for resistance to �re of cables required to maintain circuit integrity under �re conditions – Protocol C (Fire Alone), Protocol W (Fire with Water) & Protocol Z (Fire with Mechanical Shock)
BS 6622 Armoured Cables with Thermosetting Insulation for rated voltages from 3.8/6.6 kV to 19/33 kV
BS 6724 Thermosetting insulated, armoured cables of rated voltages of 600/1000 V and 1900/3300 V for �xed installations, having low emission of smoke and corrosive gases when a�ected by �re
BS 7211 Thermosetting insulated and Thermoplastic Sheathed cables for electric power, lighting and having low emission of smoke and corrosive gases when a�ected by �re.
BS 7629-1 300/500 V �re resistant screened cables having low emission of smoke and corrosive gases when a�ected by �re - Part 1: Multicore and multi pair cables
BS 7655-4.2 Insulating and sheathing materials for cables. PVC sheathing compounds
BS 7835 Armoured Cables with Thermosetting Insulation having low emission of smoke and corrosive gases when a�ected by �re
BS 7846 Thermosetting insulated, armoured Fire Resistant cables having low emission of smoke and corrosive gases when a�ected by �re
BS 7870-1 LV and MV polymeric insulated cables for use by distribution and generation utilities - General
BS 7870-2 LV and MV polymeric insulated cables for use by distribution and generation utilities - Methods of test
BS 7870-3.10 PVC Insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors
BS 7870-4.10 Distribution Cables (Single Core) with extruded insulation of rated voltages of 11 kV to 33 kV
BS 7870-4.20 Distribution Cables (Three Core) with extruded insulation of rated voltage of 11 kV
BS 7870-5 Polymeric insulated aerial bundled conductors (ABC) of rated voltage 0.6/1 kV for overhead distribution
BS 7870-8.1 Single wire armoured and PVC sheathed multicore cable with copper conductors
BS 7870-8.2 Single Wire Armoured and PVC Sheathed Multipair Cable with Copper Conductors
BS 7870-8.3 Single wire armoured and PVC sheathed multicore cable with copper conductors, having reduced �re propagation performance
BS 7870-8.4 Single Wire or double steel tape armoured and PVC Sheathed multipair cable with copper conductors, having reduced �re propagation performance low emission of smoke
BS 7870-8.5 Single wire armoured and unarmoured multicore cables with copper conductor and non-halogenated sheath
BS 7870-8.6 Single wire or double steel tape armoured and non-halogenated sheathed multipair cable with copper conductors
BS 7889 Thermosetting Insulated, non-armoured cables with a voltage of 600/1100 V for �xed installations
BS 8434-2 Method of test for resistance to �re of unprotected small cables for use in emergency circuits – BS EN 50200 with a 930OC �ame and with Water/Mechanical Shock (Classi�cation – 120 Minutes)
BS 8491 Method for assessment of �re integrity of large diameter power cables (Fire with Mechanical Shock & burst of Water Jet) Category-30 Minutes, 60 Minutes, 90 Minutes & 120 Minutes
BS EN 50200 Method of test for resistance to �re of unprotected small cables for use in emergency circuits
BS EN 50288-7 Multi Element Metallic Cables Used in Analogue and Digital Communication and Control
BS EN 50289 Communication Cables
BS EN 50214 Flat Polyvinyl Chloride Sheathed Flexible Cables
BS EN 50305 Railway applications. Railway rolling stock cables having special �re performance. Test methods.
BS EN 50395 Electrical test methods for low voltage energy cables
BS EN 50396 Non-electrical test methods for low voltage energy cables
BS EN 50363 Insulating, sheathing and covering materials for low voltage energy cables
BS EN 50397-1 Covered Conductors for overhead lines and related accessories
BS EN 50525-1 Electric Cables. Low voltage energy cables of rated voltages up to and including 450/750 V – General requirements
BS EN 50525-2-11 Low voltage energy cables of rated voltages up to and including 450/750 V – Cables for general applications. Flexible Cables with Thermoplastic PVC Insulation
BS EN 50525-2-21 Low voltage energy cables of rated voltages up to and including 450/750 V – Cables for general applications. Flexible Cables with cross-linked elastomeric insulation
BS EN 50525-2-31 Low voltage energy cables of rated voltages up to and including 450/750 V – Cables for general applications. Single Core non-sheathed cables with thermoplastic PVC Insulation
BS EN 50525-2-41 Low voltage energy cables of rated voltages up to and including 450/750 V – Cables for general applications. Single core cables with crosslinked silicone rubber insulation
BS EN 50525-2-42 Low voltage energy cables of rated voltages up to and including 450/750 V – Cables for general applications. Single core non-sheathed cables with crosslinked EVA insulation
BS EN 50525-2-83 Low voltage energy cables of rated voltages up to and including 450/750 V – Cables for general applications. Multicore Cables with cross-linked Silicon Rubber insulation
BS EN 50525-3-41 Low voltage energy cables of rated voltages up to and including 450/750 V – Cables with special �re performance. Single Core non-sheathed cables with halogen-free cross-linked insulation
BS EN 50618 Electrical Cables for photovoltaic system
RESEARCH &DEVELOPMENT
COMPLETE TESTING FACILITIES AS PER OTHER INTERNATIONAL STANDARDS FOR CABLES
COMPLETE TESTING FACILITIES AS PER INTERNATIONAL AND NATIONAL STANDARDS FOR TRANSFORMERS
NFC 33-209 Bundled Assembled Cores for Overhead Systems of rated voltages 0.6/1kV
SANS 6100 Aerial Bundled Conductors - Performance of Supporting Cores under Mechanical and Thermal Stresses
ANSI MC-96.1 Thermocouple compensating cables
NEMA WC-53 Standard Test Methods for Extruded Dielectric Power, Control, Instrumentation, and Portable Cables for Test
NEMA WC-57 Standard for control, thermocouple extension and instrumentation cable
NEMA WC-70 Power Cables rated 2000V or less for the distribution of Electrical Energy
PAS 5308 (Part-1) Polyethylene insulated, thermosetting sheathed cable
PAS 5308 (Part-2) PVC insulated control and instrumentation cable
IS 1180 (Part-1) Outdoor/indoor type oil immersed distribution transformers upto and including 2500 kVA, 33 kV
IS 2026 (Part-1) Power transformers
IS 2026 (Part-2) Power transformers temperature rise
IS 2026 (Part-3) Power transformers insulation levels, dielectric tests and external clearances in air
IS 2026 (Part-4) Power transformers terminal marking, tapping and connection
IS 2026 (Part-10) Power transformers: Determination of sound levels
IS 11171 Dry-type power transformers
IEC 60076-1 Power transformers - Part 1: General
IEC 60076-3 Power transformers - Part 3: Insulation levels, dielectric tests, external clearance in air
IEC 60076-11 Dry-type transformers
IEEE 57.12.60 Test procedure for thermal evaluation of insulation systems for dry-type power and distribution transformers, including open-wound, solid-cast and resin- encapsulated transformers
IEEE 57.12.90 IEEE standard test code for liquid-immersed distribution, power and regulating transformers
ASTM D - 3359 Standard test methods for rating adhesion by tape test
IS 335 Moisture content in oil in transformers
GP 275 CBIP - Manuals of TransformersGP 295GP 317
RESEARCH &DEVELOPMENT
OUR STATE-OF-THE-ART LABORATORY IS:
OUR FOOTPRINTS DEFINE OUR JOURNEY TOWARDS ACHIEVING AND SUSTAINING LEADERSHIP IN OUR AREAS OF SERVICE.
• An ISO/IEC 17025:2017 certi�ed Electro-technical Testing Laboratory accredited to NABL (ILAC-MRA) and approved by BIS (Ministry of Consumer A�airs, Food & Public Distribution, Government of India)
• One of the only three laboratories in India with NABL (ILAC-MRA) Accreditation & BIS approval for complete testing of HT Cables up to 66 kVE.
• Serving Customers across the GLOBE and PAN INDIA.
• An NABL (ILAC-MRA) accredited laboratory for Testing of cables with Circuit Integrity under Fire Conditions/Fire Resistant Cables/ Solar Cables, etc./having complete Testing facility for Fluorine content and Toxicity Tests.
• Located in an area of about 18,000 sq.ft.
• Providing Consultancy for speciality cables, including Circuit Integrity Cables and Optical Fibre Cables.