AMS® CAT BOSS™ Cleaner Procedure

1
CAT BOSS OPERATING INSTRUCTIONS It is important that tools are hydro-tested prior to each use. Do not modify, change or adapt any other equipment to these tools. Do not use in confined spaces. Do not use any leverage device or pipe wrench to assist tool. 1. Connect nitrogen hose (with swivel) to tool. 2. Be certain packing gland is tight and will not leak during use. 3. Close vent valve (1/4 turn ball valve on side of tool) 4. With tool fully retracted, attach tool to process connection. Tighten sufficiently to prevent leaks. Open nitrogen supply to tool. 5. Open process valve and check for leaks. If any leaks, immediately close process valve. If no leaks appear, open process valve to the full open position. 6. Rotate ratchet handle and push fully into process 7. Open vent valve to allow catalyst to be removed from aeration tap. 8. When aeration tap has been cleared, there will be no catalyst debris venting from valve. 9. Close vent valve and retract tool fully. When fully retracted the process valve can be closed and the tool removed from the process connection. NITROGEN FLOW NITROGEN FLOW 1. connect nitrogen hose 2. check for leaks at packing gland 3. close valve 4. attach tool to process 5. open process valve 6. rotate ratchet handle and push fully into process NITROGEN FLOW 7. Open valve and vent catalyst debris

Transcript of AMS® CAT BOSS™ Cleaner Procedure

Page 1: AMS® CAT BOSS™ Cleaner Procedure

CAT BOSS

OPERATING INSTRUCTIONS

It is important that tools are

hydro-tested prior to each use.

Do not modify, change or adapt

any other equipment to these

tools. Do not use in confined

spaces. Do not use any

leverage device or pipe wrench

to assist tool.

• 1. Connect nitrogen hose

(with swivel) to tool.

• 2. Be certain packing

gland is tight and will not

leak during use.

• 3. Close vent valve (1/4

turn ball valve on side of

tool)

• 4. With tool fully

retracted, attach tool to

process connection.

Tighten sufficiently to

prevent leaks. Open

nitrogen supply to tool.

• 5. Open process valve

and check for leaks. If

any leaks, immediately

close process valve. If

no leaks appear, open

process valve to the full

open position.

• 6. Rotate ratchet handle

and push fully into

process

• 7. Open vent valve to

allow catalyst to be

removed from aeration

tap.

• 8. When aeration tap has

been cleared, there will

be no catalyst debris

venting from valve.

• 9. Close vent valve and

retract tool fully. When

fully retracted the

process valve can be

closed and the tool

removed from the

process connection.

NITROGEN FLOW

NITROGEN FLOW

1. connect

nitrogen

hose

2. check for

leaks at

packing

gland 3. close valve

4. attach tool to process

5. open process valve

6. rotate ratchet

handle and push

fully into process

NITROGEN FLOW

7. Open valve and vent catalyst debris