Amos Lightv2
description
Transcript of Amos Lightv2
-
AMOS LIGHT TO ANOC 1st Line
-
Amos Light Test for ANOC 1st Line V2 20-02-2014
Classification C2 Page 2 of 19
Document Controls
Version Notes Author Date Approval
Date
0.1 Draft for review Joo Loiro 18/03/14
Revision 2 Joo Loiro 08/04/14
Description
This document serves to elucidate the Users ANOC 1st LINE on the use of AMOS tool.
Contents
1. AMOS Light ................................................................................................................................................ 3
1.1 Initializing Amos ............................................................................................................................................... 5
1.2 Alarms ................................................................................................................................................................... 6
1.3 Hardware ........................................................................................................................................................... 10
1.4 Cells..................................................................................................................................................................... 13
1.5 Software ............................................................................................................................................................ 14
1.6 Transmission ................................................................................................................................................... 15
1.7 Stats .................................................................................................................................................................... 18
-
Amos Light Test for ANOC 1st Line V2 20-02-2014
Classification C2 Page 3 of 19
1. AMOS Light
The present demonstration, was made on RBS
In the end, is expected to know check:
Alarms
Hardware
Cells
Software
Transmission
Stats
-
Amos Light Test for ANOC 1st Line V2 20-02-2014
Classification C2 Page 4 of 19
Operations of 1st line
Actions on RBS
TYPE TASKS STATE COMMAND
ALARMS ALARM CHECK alt; ala
ALARM CONFIGURATION get . Alarm
ALARM TESTING alt; ala
ALARM LOG lga
HARDWARE
CABINET get 0
CHECK BOARDS Cabx & Cab
LOCK AND UNLOCK BOARDS lbl board & ldeb board
CELLS
RADIO LINKS hget radio; get . Commcontext
SOFTWARE
LIST CV cvls
SET CV cvset
RESTART acc 0 manualrestart
TRANSMISSION
SYNCHRONISM get 10
STATUS st E1
TYPE OF TRANSMISSION get . Iub
CONFIGURATION ATM: stv ; IP: get . Gigabit -> get < Mo name >
TESTING
IP & ATM: pdiff e1; ATM: acc .*vcltp=vc eteloopback
STATS
SITE pmr and pick the following options
IUB Pget iub
-
Amos Light Test for ANOC 1st Line V2 20-02-2014
Classification C2 Page 5 of 19
1.1 Initializing Amos
Please open the Common Explorer and pick a node.
And Open a Amos session.
-
Amos Light Test for ANOC 1st Line V2 20-02-2014
Classification C2 Page 6 of 19
Loading all Managed Objects that match a specified word, and all the children of
these Managed Objects
To load all Managed Objects that match a specified word, and all the children of these
Managed Objects, use the following command:
Lt all:
1.2 Alarms Usefull Commands:
ALT: To print all alarms chronologically.
-
Amos Light Test for ANOC 1st Line V2 20-02-2014
Classification C2 Page 7 of 19
ALA: To print the active alarm list with detailed information on the alarm.
Get . Alarm: To Print the configuration of external alarm.
-
Amos Light Test for ANOC 1st Line V2 20-02-2014
Classification C2 Page 8 of 19
If we want to configure any alarm we can do for example:
The following command print every external alarms with the proxy number.
pr Equipment=1,AuxPlugInUnit=1,XalmDeviceGroup=1,AlmDeviceSet=1,AlmDevice
Now we can do the command get with the proxy number. In this case, is Proxy 503
Get 503 Proxi ID
-
Amos Light Test for ANOC 1st Line V2 20-02-2014
Classification C2 Page 9 of 19
If the purpose, is to change any parameter from the configuration of external alarm. The Mo must
be locked. To lock an MO, could be used a Set command to affect the administrativeState value.
For example:
Set
set Equipment=1,AuxPlugInUnit=1,XalmDeviceGroup=1,AlmDeviceSet=1,AlmDevice=1 administrativeState 0
or
set 503 administrativeState 0
An easy way to do it, is using the following commands.
Lbl/bl to lock
lbl
lbl Equipment=1,AuxPlugInUnit=1,XalmDeviceGroup=1,AlmDeviceSet=1,AlmDevice=1
or
lbl 503
Ldeb/deb to unlock
ldeb
ldeb Equipment=1,AuxPlugInUnit=1,XalmDeviceGroup=1,AlmDeviceSet=1,AlmDevice=1
or
ldeb 503
after this mo locked, may proceed with the changes. Please dont forget, to unlock the alarm at the end. If not the alarms will stay inhibit.
Lga: Displays all of the past alarms.
The password of node is wireless
-
Amos Light Test for ANOC 1st Line V2 20-02-2014
Classification C2 Page 10 of 19
1.3 Hardware
Usefull Commands:
Get 0: Print cabinet info like, cabinet type and serial.
Cab: cab - Prints MP/BP HW info and LED status, MP temperature, and COREMGR status.
-
Amos Light Test for ANOC 1st Line V2 20-02-2014
Classification C2 Page 11 of 19
Cabx: Same as cab plus LED and HW info for the XP boards.
-
Amos Light Test for ANOC 1st Line V2 20-02-2014
Classification C2 Page 12 of 19
Lbl [s] & ldeb: Lock or soft-lock & Unlock MO(s).
Lbl/bl to lock.
On this example we use a ASC
lbl
lbl Equipment=1,SectorAntenna=2,AuxPlugInUnit=1
or
lbl 177
Ldeb/deb to unlock
ldeb
ldeb Equipment=1,SectorAntenna=2,AuxPlugInUnit=1
or
ldeb 177
-
Amos Light Test for ANOC 1st Line V2 20-02-2014
Classification C2 Page 13 of 19
1.4 Cells
Usefull Commands:
Hget radio Print horizontally, one line per sector and carrier (instead of one line per
attribute)
Get . commcontext Display all of the established radio links.
-
Amos Light Test for ANOC 1st Line V2 20-02-2014
Classification C2 Page 14 of 19
1.5 Software Usefull Commands:
Cvls Displays both the current CV information and CV list.
Cv startable, CV loaded, CV Executing and the last CV Created.
Upgrade software available on RBS.
Configuration version Name Sofware version Responsible fro the CV
Cvset Set a CV as startable.
-
Amos Light Test for ANOC 1st Line V2 20-02-2014
Classification C2 Page 15 of 19
Acc 0 manualrestart Restart RBS.
After restart, RBS will be start on CV NTP_new_OK
1.6 Transmission Usefull Commands:
Get Synch Displays the sync Information.
On this output is printed the state of the sync, his reference.and if its stable or not.
St E1: Check the status of the E1.
-
Amos Light Test for ANOC 1st Line V2 20-02-2014
Classification C2 Page 16 of 19
Get iub: Print the Iub interface.
Default gateway
Type of IUB
Configuration:
ATM:
Stv Display state, user, and bandwidth usage for ATM ports.
Get ima Display the configuration of the IMA Group
Required Number of Links
-
Amos Light Test for ANOC 1st Line V2 20-02-2014
Classification C2 Page 17 of 19
IP: Get Giga Display the configuration of the gigabit port.
Testing:
ATM: Acc .*vcltp=vc eteloopback This could be used to check if there was a transmission problem.
ATM&IP: pdiff e1 Print incrementation of E1 PM attributes.
-
Amos Light Test for ANOC 1st Line V2 20-02-2014
Classification C2 Page 18 of 19
1.7 Stats Usefull Commands:
Pmr produce PM KPI reports
Option 1 RSSI Whole Period
Rssi Value should be between -100 & -110
-
Amos Light Test for ANOC 1st Line V2 20-02-2014
Classification C2 Page 19 of 19
Option 2 RSSI Rop by Rop (Each rop is equal to 15 minutes)
Option 7 IubDataStrams Performance
Option 9 RSSI Rop by Rop (Each rop is equal to 15 minutes)