Amos Lightv2

19
AMOS LIGHT TO ANOC 1 st Line

description

grdgdrggerger

Transcript of Amos Lightv2

  • AMOS LIGHT TO ANOC 1st Line

  • Amos Light Test for ANOC 1st Line V2 20-02-2014

    Classification C2 Page 2 of 19

    Document Controls

    Version Notes Author Date Approval

    Date

    0.1 Draft for review Joo Loiro 18/03/14

    Revision 2 Joo Loiro 08/04/14

    Description

    This document serves to elucidate the Users ANOC 1st LINE on the use of AMOS tool.

    Contents

    1. AMOS Light ................................................................................................................................................ 3

    1.1 Initializing Amos ............................................................................................................................................... 5

    1.2 Alarms ................................................................................................................................................................... 6

    1.3 Hardware ........................................................................................................................................................... 10

    1.4 Cells..................................................................................................................................................................... 13

    1.5 Software ............................................................................................................................................................ 14

    1.6 Transmission ................................................................................................................................................... 15

    1.7 Stats .................................................................................................................................................................... 18

  • Amos Light Test for ANOC 1st Line V2 20-02-2014

    Classification C2 Page 3 of 19

    1. AMOS Light

    The present demonstration, was made on RBS

    In the end, is expected to know check:

    Alarms

    Hardware

    Cells

    Software

    Transmission

    Stats

  • Amos Light Test for ANOC 1st Line V2 20-02-2014

    Classification C2 Page 4 of 19

    Operations of 1st line

    Actions on RBS

    TYPE TASKS STATE COMMAND

    ALARMS ALARM CHECK alt; ala

    ALARM CONFIGURATION get . Alarm

    ALARM TESTING alt; ala

    ALARM LOG lga

    HARDWARE

    CABINET get 0

    CHECK BOARDS Cabx & Cab

    LOCK AND UNLOCK BOARDS lbl board & ldeb board

    CELLS

    RADIO LINKS hget radio; get . Commcontext

    SOFTWARE

    LIST CV cvls

    SET CV cvset

    RESTART acc 0 manualrestart

    TRANSMISSION

    SYNCHRONISM get 10

    STATUS st E1

    TYPE OF TRANSMISSION get . Iub

    CONFIGURATION ATM: stv ; IP: get . Gigabit -> get < Mo name >

    TESTING

    IP & ATM: pdiff e1; ATM: acc .*vcltp=vc eteloopback

    STATS

    SITE pmr and pick the following options

    IUB Pget iub

  • Amos Light Test for ANOC 1st Line V2 20-02-2014

    Classification C2 Page 5 of 19

    1.1 Initializing Amos

    Please open the Common Explorer and pick a node.

    And Open a Amos session.

  • Amos Light Test for ANOC 1st Line V2 20-02-2014

    Classification C2 Page 6 of 19

    Loading all Managed Objects that match a specified word, and all the children of

    these Managed Objects

    To load all Managed Objects that match a specified word, and all the children of these

    Managed Objects, use the following command:

    Lt all:

    1.2 Alarms Usefull Commands:

    ALT: To print all alarms chronologically.

  • Amos Light Test for ANOC 1st Line V2 20-02-2014

    Classification C2 Page 7 of 19

    ALA: To print the active alarm list with detailed information on the alarm.

    Get . Alarm: To Print the configuration of external alarm.

  • Amos Light Test for ANOC 1st Line V2 20-02-2014

    Classification C2 Page 8 of 19

    If we want to configure any alarm we can do for example:

    The following command print every external alarms with the proxy number.

    pr Equipment=1,AuxPlugInUnit=1,XalmDeviceGroup=1,AlmDeviceSet=1,AlmDevice

    Now we can do the command get with the proxy number. In this case, is Proxy 503

    Get 503 Proxi ID

  • Amos Light Test for ANOC 1st Line V2 20-02-2014

    Classification C2 Page 9 of 19

    If the purpose, is to change any parameter from the configuration of external alarm. The Mo must

    be locked. To lock an MO, could be used a Set command to affect the administrativeState value.

    For example:

    Set

    set Equipment=1,AuxPlugInUnit=1,XalmDeviceGroup=1,AlmDeviceSet=1,AlmDevice=1 administrativeState 0

    or

    set 503 administrativeState 0

    An easy way to do it, is using the following commands.

    Lbl/bl to lock

    lbl

    lbl Equipment=1,AuxPlugInUnit=1,XalmDeviceGroup=1,AlmDeviceSet=1,AlmDevice=1

    or

    lbl 503

    Ldeb/deb to unlock

    ldeb

    ldeb Equipment=1,AuxPlugInUnit=1,XalmDeviceGroup=1,AlmDeviceSet=1,AlmDevice=1

    or

    ldeb 503

    after this mo locked, may proceed with the changes. Please dont forget, to unlock the alarm at the end. If not the alarms will stay inhibit.

    Lga: Displays all of the past alarms.

    The password of node is wireless

  • Amos Light Test for ANOC 1st Line V2 20-02-2014

    Classification C2 Page 10 of 19

    1.3 Hardware

    Usefull Commands:

    Get 0: Print cabinet info like, cabinet type and serial.

    Cab: cab - Prints MP/BP HW info and LED status, MP temperature, and COREMGR status.

  • Amos Light Test for ANOC 1st Line V2 20-02-2014

    Classification C2 Page 11 of 19

    Cabx: Same as cab plus LED and HW info for the XP boards.

  • Amos Light Test for ANOC 1st Line V2 20-02-2014

    Classification C2 Page 12 of 19

    Lbl [s] & ldeb: Lock or soft-lock & Unlock MO(s).

    Lbl/bl to lock.

    On this example we use a ASC

    lbl

    lbl Equipment=1,SectorAntenna=2,AuxPlugInUnit=1

    or

    lbl 177

    Ldeb/deb to unlock

    ldeb

    ldeb Equipment=1,SectorAntenna=2,AuxPlugInUnit=1

    or

    ldeb 177

  • Amos Light Test for ANOC 1st Line V2 20-02-2014

    Classification C2 Page 13 of 19

    1.4 Cells

    Usefull Commands:

    Hget radio Print horizontally, one line per sector and carrier (instead of one line per

    attribute)

    Get . commcontext Display all of the established radio links.

  • Amos Light Test for ANOC 1st Line V2 20-02-2014

    Classification C2 Page 14 of 19

    1.5 Software Usefull Commands:

    Cvls Displays both the current CV information and CV list.

    Cv startable, CV loaded, CV Executing and the last CV Created.

    Upgrade software available on RBS.

    Configuration version Name Sofware version Responsible fro the CV

    Cvset Set a CV as startable.

  • Amos Light Test for ANOC 1st Line V2 20-02-2014

    Classification C2 Page 15 of 19

    Acc 0 manualrestart Restart RBS.

    After restart, RBS will be start on CV NTP_new_OK

    1.6 Transmission Usefull Commands:

    Get Synch Displays the sync Information.

    On this output is printed the state of the sync, his reference.and if its stable or not.

    St E1: Check the status of the E1.

  • Amos Light Test for ANOC 1st Line V2 20-02-2014

    Classification C2 Page 16 of 19

    Get iub: Print the Iub interface.

    Default gateway

    Type of IUB

    Configuration:

    ATM:

    Stv Display state, user, and bandwidth usage for ATM ports.

    Get ima Display the configuration of the IMA Group

    Required Number of Links

  • Amos Light Test for ANOC 1st Line V2 20-02-2014

    Classification C2 Page 17 of 19

    IP: Get Giga Display the configuration of the gigabit port.

    Testing:

    ATM: Acc .*vcltp=vc eteloopback This could be used to check if there was a transmission problem.

    ATM&IP: pdiff e1 Print incrementation of E1 PM attributes.

  • Amos Light Test for ANOC 1st Line V2 20-02-2014

    Classification C2 Page 18 of 19

    1.7 Stats Usefull Commands:

    Pmr produce PM KPI reports

    Option 1 RSSI Whole Period

    Rssi Value should be between -100 & -110

  • Amos Light Test for ANOC 1st Line V2 20-02-2014

    Classification C2 Page 19 of 19

    Option 2 RSSI Rop by Rop (Each rop is equal to 15 minutes)

    Option 7 IubDataStrams Performance

    Option 9 RSSI Rop by Rop (Each rop is equal to 15 minutes)