Ammonia Unloading Storage
-
Upload
mohamed-ghadhab -
Category
Documents
-
view
67 -
download
3
Transcript of Ammonia Unloading Storage
Industries
Benefits Single Source Accountability Pre-Packaged Modular Design Costs Less
Than Component Based Site-Built Systems Reducing Overall Project Cost
Minimizes Field Erection Time -Shorter Overall Project Delivery Schedule
Complete System Function TestingPrior To Shipment
24/7 Customer Service
Industry Standards Vessels Code Stamped ASME Section VIII &
National Board Registered Piping Designed to ANSI B31.1/ANSI B31.3 Pipe Fabrication to ASME Section IX Structural Steel Assembly Designed to AWS D1.1 Complete System Designed to API RP 550 & K61.1
INTEGRATED FLOW SOLUTIONS 9800 Northwest Freeway, Suite 205 Houston, Texas 77092 713-956-9473
ANAM-100.0
Integrated Flow Solutions Anhydrous AmmoniaUnloading Stations & Storage/Forwarding Systemsare designed to unload Anhydrous Ammonia fromtransports into a modular Storage/Vaporizer Systemwhich includes a storage tank, vaporizer,instrumentation and controls. The complete system isdesigned to minimize field assembly. The vaporizingsystem is designed to transfer the Anhydrous Ammoniato the Ammonia Flow Control Unit (AFCU).
Anhydrous AmmoniaUnloading Station &Storage/Vaporizer System
Standard Features INTEGRASAFETM Unloading Station
Local Indication of:Tank LevelTank PressureFlow Indication
Local Manual/Automated Valve Operation Storage/Forwarding System
Vessel Storage Up to 30,000 Gallons Single & Double Wall Carbon Steel Vessels INTEGRAHEATTM Electrical Vaporizer ASME
Code Stamped (Locally Mounted) Full Thyrister (SCR) Control Panel with
Redundant Safety Shutdown System (LocallyMounted) per NEC & NFPA
Complete Factory Function Test
Optional Features UL or CSA Listed Heater and Control Panel
Assembly per NEC & NFPA Class 1, Div. 2 Hazardous Locations Compliance with Plant/Engineering Specifications
Additional Services “Aspen Plus” Process Simulation Software Used
To Guarantee Process Conditions Installation/Training/Start-Up Supervision Extended Warranty Nationwide Service Network
EMISSIONSGENERALPOWER
www.IFSolutions.com
www.IFSolutions.com
Anhydrous Ammonia UnloadingStation & Storage Vaporizer System
INTEGRATED FLOW SOLUTIONS 9800 Northwest Freeway, Suite 205 Houston, Texas 77092 713-956-9473LIT ANAM-100.0 10022004 IFS These materials contain proprietary information and may not be reproduced without prior written permission from Integrated Flow Solutions.
WORKING VOLUME -GALLONS LENGTH - X WIDTH - Y HEIGHT - Z WEIGHT - LBS.
6,000 20’ 11’ 14’ 15,00010,000 34’ 11’ 14’ 25,00014,000 50’ 11’ 14’ 35,00018,000 60’ 11’ 14’ 45,00022,000 75’ 12’ 16’ 55,000
ATMOS.
ATMOS.
ATMOS.
DRAIN
ATMOS.
NC
ANHYDROUS AMMONIA TANK
VAPORIZER ASSY.ELECTRIC HEATER
24" MANWAY
ATMOS.
ATMOS.
S
FC
ATMOS.
SCR PANEL
SKID LIMITS
I
AT
I
AMMONIATRANS.
PERPENDICULAR TO WORLD COORDINATES.ALL NOZZLES SHALL BE ORIENTEDNOTE:
ELECTRIC HEATERVAPORIZER ASSY.
VENT
LO
ADIN
G S
KID
ANHY
DROU
S AM
MON
IA IN
LET
OUT
LET
TO P
ROCE
SS
BY CUSTOMER1/2" INSTRUMENT AIR
SKID LIMITS
2"x3"
1"
1"
2"x1"
1"1"x
1/2"
2"
2"
2"x1
" 2" 2"
ATMOS.
2"x1"
2"
2"2"
1 1/2"
2"x1
1/2
"
2"x1
1/2
"
2"
E L E V A T I O N V I E W
L VESSELC
VAPORIZER-02 (FAR SIDE)VAPORIZER-01 (NEAR SIDE)
8070
60
10090
5040
3020
100
010
2030
40 50
90100
60
7080
01020
304050
90100
6070
80
"X" OVERALL SKID LENGTH
"Z" A
PP
RO
X. O
VE
RA
LL H
EIG
HT
P L A N V I E W VAPORIZER-01
VAPORIZER-02
"X" OVERALL SKID LENGTH
"Y" O
VE
RA
LL S
KID
WID
TH
www.IFSolutions.com