Amit K Barui, Balaji Srinivasan, David Erickson and … Kumar...Amit K Barui, Balaji Srinivasan,...
Transcript of Amit K Barui, Balaji Srinivasan, David Erickson and … Kumar...Amit K Barui, Balaji Srinivasan,...
![Page 1: Amit K Barui, Balaji Srinivasan, David Erickson and … Kumar...Amit K Barui, Balaji Srinivasan, David Erickson and Saurabh Mehta Division of Nutritional Sciences, Sibley School of](https://reader035.fdocuments.in/reader035/viewer/2022063006/5fb733294a80953de27588d6/html5/thumbnails/1.jpg)
Amit K Barui, Balaji Srinivasan, David Erickson and Saurabh Mehta
Division of Nutritional Sciences,
Sibley School of Mechanical and Aerospace Engineering
Cornell University, Ithaca, NY
![Page 2: Amit K Barui, Balaji Srinivasan, David Erickson and … Kumar...Amit K Barui, Balaji Srinivasan, David Erickson and Saurabh Mehta Division of Nutritional Sciences, Sibley School of](https://reader035.fdocuments.in/reader035/viewer/2022063006/5fb733294a80953de27588d6/html5/thumbnails/2.jpg)
SAFE-PhoneSmartphone based Aflatoxin Evaluation
• 4’ diagonal size, with a touch screen.
• Internet of Things operating system.
• Available to transmission data with Wi-Fi, Bluetooth, and 3G GSM
networks
• Confocal fluorescence and visible optical sensor.
• Excite fluorescence image and capture immunoassay signals.
• Ultra-compact reader
• Europium nanoparticle and Gold nanoparticle based lateral flow assay.
TIDBIT ver. #1
TIDBIT ver. #2
![Page 3: Amit K Barui, Balaji Srinivasan, David Erickson and … Kumar...Amit K Barui, Balaji Srinivasan, David Erickson and Saurabh Mehta Division of Nutritional Sciences, Sibley School of](https://reader035.fdocuments.in/reader035/viewer/2022063006/5fb733294a80953de27588d6/html5/thumbnails/3.jpg)
![Page 4: Amit K Barui, Balaji Srinivasan, David Erickson and … Kumar...Amit K Barui, Balaji Srinivasan, David Erickson and Saurabh Mehta Division of Nutritional Sciences, Sibley School of](https://reader035.fdocuments.in/reader035/viewer/2022063006/5fb733294a80953de27588d6/html5/thumbnails/4.jpg)
Aflatoxin B1 determination in peanut samples
0 156 312 625 1250 2500 5000 10000
Aflatoxin B1 pg/mL
T
C
• Gold nanoparticle based lateral flow immunoassay.
• Assay covers the wide aflatoxin concentration range 300-5000 pg/mL.
• Limit of detection as low as 300 pg/mL
• Different batches of test strips were also analyzed to ascertain the interbatch variability
Aflatoxin - absence
Aflatoxin -presence
Anti-aflatoxin gold nanoparticle conjugate Aflatoxin-BSA conjugate Anti-rat antibodyAflatoxin
T = Test line C = Control line
T C
T C
T C
T C
625 pg/mL 5000 pg/mL
![Page 5: Amit K Barui, Balaji Srinivasan, David Erickson and … Kumar...Amit K Barui, Balaji Srinivasan, David Erickson and Saurabh Mehta Division of Nutritional Sciences, Sibley School of](https://reader035.fdocuments.in/reader035/viewer/2022063006/5fb733294a80953de27588d6/html5/thumbnails/5.jpg)
Steps for aflatoxin B1 determination in peanut samples
![Page 6: Amit K Barui, Balaji Srinivasan, David Erickson and … Kumar...Amit K Barui, Balaji Srinivasan, David Erickson and Saurabh Mehta Division of Nutritional Sciences, Sibley School of](https://reader035.fdocuments.in/reader035/viewer/2022063006/5fb733294a80953de27588d6/html5/thumbnails/6.jpg)
Acknowledgements