Amine Syste ms Rel iab ility Pro gra m - Pall Corporation · PDF fileAmine Syste ms Rel iab...

5
Comprehensive Fluid Management for Amine Systems Amine Systems Reliability Program: Contamination Evaluation Evaluation Clean-Up Phase Phase Technology Implementation Implementation Long-Term Service Program Service Program Process Survey / Feasibility Study Feasibility Study Technical Recommendations / Proposals Proposals

Transcript of Amine Syste ms Rel iab ility Pro gra m - Pall Corporation · PDF fileAmine Syste ms Rel iab...

Page 1: Amine Syste ms Rel iab ility Pro gra m - Pall Corporation · PDF fileAmine Syste ms Rel iab ility Pro gra m: Cont amin atio n ... any carry-over carbon bed fines and prevent fouling

Comprehensive Fluid Managementfor Amine Systems

Amine Systems Reliability Program:

ContaminationEvaluationEvaluation

Clean-Up PhasePhase

Technology ImplementationImplementation

Long-Term Service ProgramService Program

Process Survey / Feasibility StudyFeasibility Study

Technical Recommendations /

ProposalsProposals

Page 2: Amine Syste ms Rel iab ility Pro gra m - Pall Corporation · PDF fileAmine Syste ms Rel iab ility Pro gra m: Cont amin atio n ... any carry-over carbon bed fines and prevent fouling

Where to Apply Separation Equipment

2

1

3

4 7

6

5

mR

2

1

3

4 7

6

5

not all pumR

2

1

3

4 7

6

5

Treatment optionot all purificatimay apply. Contact yourRepresentative f

solutions.

2

1

3

4 7

6

5

Treatment optionot all purificatimay apply. Contact yourRepresentative f

solutions.

2

1

3

4 7

6

5

Treatment optionot all purificatimay apply. Contact yourRepresentative f

solutions.

2

1

3

4 7

6

5Treatment options will vary andnot all purifications steps listedmay apply. Contact yourRepresentative for optimized

solutions.

4 7

5

Sour Inlet Gas - Pall SepraSol™ Liquid/Gas Coalescers will removeentrained liquid and solid aerosols in the sour inlet gas and reduce aminecontamination. Removing contaminants at the source gas will effectivelyreduce contactor foaming, corrosion rates, and fouling in the amine systemincluding contactor trays, heat exchangers, and the regenerator.

Sweet Outlet Gas - Pall SepraSol Liquid/Gas Coalescers will prevent aminecarry-over from passing downstream where they may lead to contaminationof additional purification processes such as glycol or molecular sieve driers,or recycle compressors, and can be used to debottleneck higher flow rates.

Rich Amine - Pall Absolute-Rated Liquid Particulate Filters will remove corrosion products that may enter the amine system through the inlet sourgas or sour LPG, or are formed by corrosion of metallic components in theamine circuit.

Rich Amine - Pall PhaseSep® Liquid/Liquid Coalescers will remove dispersedoil or hydrocarbons in the amine that can lead to heat exchanger andregenerator fouling.

Lean Amine - Pall Absolute-Rated Liquid Particulate Filters will remove corrosion products and solids to protect the activated carbon bed.

Lean Amine - Pall Absolute-Rated Liquid Particulate Filters will captureany carry-over carbon bed fines and prevent fouling of the amine contactor.

Lean Amine - Eco-Tec AmiPur1 Heat Stable Salt (HSS) Removal System willremove dissolved impurities to maintain healthy amine circulating systemswith <1% HSS content. A continuous purification process is used on a slipstream of lean amine to ensure reliable performance and consistentlylow HSS levels.1 AmiPur is a trademark of Eco-Tec Incorporated.

Page 3: Amine Syste ms Rel iab ility Pro gra m - Pall Corporation · PDF fileAmine Syste ms Rel iab ility Pro gra m: Cont amin atio n ... any carry-over carbon bed fines and prevent fouling

Flas

hTa

nk

Amine ContactorAmine Contactor

Amine Regenerator

Refl

ux

Trea

tmen

top

tions

will

vary

and

not

allp

uriÞ

catio

nst

eps

liste

dm

ayap

ply

.Con

tact

your

Pal

lR

epre

sent

ativ

efo

rp

rogr

amop

timiz

atio

n.

2

1

3

4

76

5

Ligh

tHC

L/G

Coal

esce

r

Sour

Inle

tGas

Swee

tOut

letG

as

Rich

Amin

e

Liqu

idPa

rtic

leFi

lter

Liqu

id-L

iqui

dCo

ales

cer

Heat

Exch

ange

r

Re-b

oile

r

Hydr

ocar

bon

Lean

Amin

e

AirC

oole

rAi

rCoo

ler

Liqu

idPa

rtic

leFi

lter

Liqu

idPa

rtic

leFi

lter

Carb

onBe

d

Sour

Inle

tLPG

Swee

tOut

letL

PG

Acid

Gas

toSu

lfurP

lant

Eco-

Tec

AmiP

urHe

atSt

able

Salts

Rem

oval

Syst

em

Reflu

xAm

ine

Pum

p

Lean

Amin

ePu

mp

L/G

Coal

esce

r

Co

mp

rehe

nsiv

eF

luid

Man

agem

ent

for

Am

ine

Sys

tem

s

Page 4: Amine Syste ms Rel iab ility Pro gra m - Pall Corporation · PDF fileAmine Syste ms Rel iab ility Pro gra m: Cont amin atio n ... any carry-over carbon bed fines and prevent fouling

What Separation Equipment to Use

Pall absolute-rated particulate filters removesolids from liquid and are available in a broadrange of removal ratings, flow capacity, andchemical compatibilities. Products includeUltipleat® High Flow filters, Marksman™ filters,Profile® filters, Profile Coreless filters, Nexis®

filters, and Claris® filters.

Pall PhaseSep Liquid/Liquid Coalescers separate two immiscible phases such as oil from amine and are able to separate difficult emulsions.

Pall SepraSol Liquid/Gas Coalescersremove entrained liquid aerosols from a gasstream such as condensed hydrocarbons orpipeline chemicals.

Eco-Tec AmiPur purification systems continuously remove Heat Stable Salts (HSS)and bicine from amines, maintaining them atlow values in a skid mounted, fully automatedunit that is proven and reliable with lowoperating cost.

Page 5: Amine Syste ms Rel iab ility Pro gra m - Pall Corporation · PDF fileAmine Syste ms Rel iab ility Pro gra m: Cont amin atio n ... any carry-over carbon bed fines and prevent fouling

Corporate Headquarters2200 Northern BoulevardEast Hills, New York 11548-1289888.873.7255 toll free516.484.5400 phone 516.484.0364 [email protected]

United KingdomEuropa House, Havant StreetPortsmouth PO1 3PDHampshire, England+44 (0) 23 9230 2357 phone+44 (0) 23 9230 2509 fax [email protected]

Visit us on the Web at www.pall.com

Pall Corporation has offices and plants throughout the world.

© Copyright 2006, Pall Corporation. Pall, , Ultipleat, Marksman, Profile, Nexis, Claris, PhaseSep, andSepraSol are trademarks of Pall Corporation. ® Indicates a Pall trademark registered in the USA. AmiPur is atrademark of Eco-Tec incorporated. is a service mark of Pall Corporation.

FCAS06 7/06

Pall Comprehensive Amine Management

Staying Below the Danger Zone Will:• Reduce or eliminate Sulfur Plant Excursions• Ensure Regenerator Reliability• Minimize Contactor Foaming Upsets• Consistently Meet Gas SpeciÞcations for H2S

Cont

amin

antL

evel

s

Consistent Contaminant Control with Pall Comprehensive Amine Management

Danger Zone

Amine Reclaimed

Time