AMBIENT NOISE LEVEL ASSESSMENT
Transcript of AMBIENT NOISE LEVEL ASSESSMENT
Rochdale Holdings Pty Ltd A.B.N. 85 009 049 067 trading as:
HERRING STORER ACOUSTICS Suite 34, 11 Preston Street, Como, W.A. 6152 P.O. Box 219, Como, W.A. 6952 Telephone: (08) 9367 6200 Facsimile: (08) 9474 2579 Email: [email protected]
AMBIENT NOISE LEVEL ASSESSMENT
440 WILLIAM STREET, EAST PERTH
BY
HERRING STORER ACOUSTICS
FOR
DOMINATION HOMES
NOVEMBER 2012
OUR REF: 15509-1-12201
ITEM 9.1.4
DOCUMENT CONTROL PAGE
AMBIENT NOISE LEVEL ASSESSMENT 440 WILLIAM STREET
Job No: 12201
Document Reference: 15509-1-12201
FOR
DOMINATION HOMES
DOCUMENT INFORMATION Author: George Watts Checked By: Tim Reynolds Date of Issue : 29 November 2012
REVISION HISTORY Revision Description Date Author Checked
DOCUMENT DISTRIBUTION
Copy No. Version No. Destination Hard Copy Electronic Copy
1 1 Domination Homes
This report has been prepared in accordance with the scope of services and on the basis of information and documents provided to Herring Storer Acoustics by the client. To the extent that this report relies on data and measurements taken at or under the times and conditions specified within the report and any findings, conclusions or recommendations only apply to those circumstances and no greater reliance should be assumed. The client acknowledges and agrees that the reports or presentations are provided by Herring Storer Acoustics to assist the client to conduct its own independent assessment.
ITEM 9.1.4
CONTENTS
1.0 INTRODUCTION 3 2.0 CONCLUSION 3 3.0 CRITERIA 3
4.0 MEASUREMENTS 3 5.0 CALCULATIONS 5 6.0 REQUIRED CONSTRUCTION 5
6.1 Walls 5 6.2 Glazing 5 6.3 Roof/Ceiling 6
7.0 CHARACTER OF INTRUSIVE NOISE DISCUSSION 6
APPENDICES
A Development Plans B Location Plan C Monitoring Results D One-Third Octave Band Data
ITEM 9.1.4
Herring Storer Acoustics Our Ref: 15509-1-12201
4
1.0 INTRODUCTION
An assessment has been undertaken of the ambient noise levels for the residential section of the proposed development at 440 William Street, Perth, to determine construction requirements to meet acceptable internal noise levels as required by the Town Of Vincent Sound Attenuation Policy. The critical noise source contributing to the ambient levels at the residential section of the development is the neighbouring nightclub. The assessment consisted of:
1. Site inspection and measurements of the ambient noise levels. 2. Determine the minimum construction requirements to achieve acceptable internal
noise levels. The details and results of the above are provided within this report.
2.0 CONCLUSION
To meet the requirements of the of Town of Vincent Sound Attenuation Policy the internal allowable LAeq noise levels for bedrooms and living areas have been set at 35 and 40 dB(A) respectively. Noise levels associated with the neighbouring nightclub are such that upgraded construction measures are required for the residential section of the development – particularly glazing treatments. With the proposed upgraded constructions, the internal sound levels set by the Town of Vincent Sound Attenuation Policy can be complied with, however the low frequency content of the noise emissions are such that they are likely to remain both audible and annoying within the proposed apartments.
3.0 CRITERIA
The Town of Vincent Sound Attenuation Policy recommends the following noise levels within Residential Buildings:
Residential buildings are to be deigned to achieve the following sounds levels :
• Leq 35 dB(A) in sleeping areas (bedrooms); and • Leq 40 dB(A) in living/work areas and other habitable rooms.
4.0 MEASUREMENTS
Due to the location of the proposed residential section of the development, on the fourth floor, the noise source of primary consideration was the adjacent nightclub. See Appendix A and B for development plans and location plans respectively. Noise emissions associated with the nightclub were recorded between 22nd and 26th November 2012, which encompasses a weekend. The noise emissions were recorded at approximately the height and location of the proposed apartment façade adjacent to the nightclub, as shown in Figures 1 and 2 below.
ITEM 9.1.4
Herring Storer Acoustics Our Ref: 15509-1-12201
5
FIGURE 1 – LOGGER LOCATION
FIGURE 2 – LOGGER LOCATION RELATIVE TO NEIGHBOURING NIGHTCLUB
The results of the monitoring are shown in Appendix C, with the one-third octave band analysis, for a typical time during which the nightclub noise emissions was prominent in Appendix D. Noise levels for the 15 minutes period where nightclub noise was prominent (midnight 24/11/2012) were measured at 59 dB LA10. The LA10 parameter has been used for the assessment, as this is the parameter prescribed by the Environmental Protection (Noise)
ITEM 9.1.4
Herring Storer Acoustics Our Ref: 15509-1-12201
6
Regulations 1997 – which governs noise emissions within Western Australia – and ensures a conservative assessment of the impact on the proposed residential apartment. Noise emissions associated with other sources in the area are considered to be limited to traffic noise. Due to construction noise dominating typical peak traffic periods, the monitoring on the 25th November 2012 (Sunday) is the only period representative of “typical” traffic conditions – albeit during periods of lesser flow than a typical weekday. Based on other developments in the area, a traffic noise level of 55 dB(A) has been conservatively assumed for the facades of the proposed apartments, based on the setback of the apartments from the road. It is noted that at the measured noise levels associated with the neighbouring nightclub, the nightclub is conservatively estimated to exceed the requirements of the Environmental Protection (Noise) Regulations 1997 by in the order of 25 dB, after 10pm.
5.0 CALCULATIONS
Calculations were carried out to determine the noise that would be received within the proposed apartments due to passing vehicles. Guidance on the calculations was taken from AS 3671-1989 “Acoustics – Road traffic noise intrusion-Building siting and construction”. The results of the calculations indicate the following minimum Rw ratings are required for the façade of the apartment nearest to the adjacent nightclub. Rw Rating Unit 4 – Bed 2 36 Unit 4 – Bed 1 36 Unit 4 – Living (sliding door) 28 Unit 2 – Bed 1 34 Unit 2 – Living 27 Unit 2 – Living (sliding door) 28 Ceilings- Living 33 Ceiling – Bedrooms 38
6.0 REQUIRED CONSTRUCTION
6.1 Walls
Standard wall constructions will satisfy the Rw ratings, and therefore no additional noise amelioration is required for the wall.
6.2 Glazing
Where the required Rw rating is less than 20, there are no specific constructions required and standard constructions will provide adequate noise reductions. Where the required Rw ratings are higher, the following tabulation indicates the types of construction that would be appropriate. It is noted that these are given as examples only, with confirmation of the performance recommended to be attained from the glazier prior to installation.
ITEM 9.1.4
Herring Storer Acoustics Our Ref: 15509-1-12201
7
Table 1 – Construction Requirements and Corresponding RW Values
RW Value Description of Construction
Windows
20 to 24 Openable - 6mm horizontal sliding window Fixed – 4mm glass
25 to 27 Openable – 6mm glass in awning type windows with mechanical winders closing on compressible seals. Fixed – 6mm glass
28 to 30
Openable – 6.38mm laminated glass in awning type windows with mechanical winders closing on compressible seals. Fixed – 6.38mm laminated glass Fixed – 10mm glass
31 to 34 Openable – 10.38mm laminated glass in awning type windows with mechanical winders closing on compressible seals. Fixed – 10.38mm laminated glass
34 to 37 Openable – 12mm laminated glass in awning type windows with mechanical winders closing on compressible seals. Fixed – 12mm laminated glass
6.3 Roof/Ceiling
The ceiling construction should be confirmed prior to construction, however generally typical ceiling constructions would be sufficient for the calculated Rw ratings within living areas. Assuming a metal deck roof, it is recommended that a second layer of plasterboard be installed within the bedrooms. The attenuation path of the sky lights shown on the provided drawings would need to be confirmed to match the required ceiling/roof sound attenuation requirements.
6.0 CHARACTER OF INTRUSIVE NOISE DISCUSSION
The intrusive noise at the façade, and in particular the windows are to be designed, includes a significant level of low frequency noise. This energy can be seen on the attached charts in Appendix D between 63 and 200 Hz.
The attenuation characteristics of glass are such that the performance is lower in these frequencies than at higher frequencies. Higher Rw rating glass can be installed, and would perform slightly higher in the low frequencies, but also performs much better in the higher frequencies. This has the unintended effect of emphasising the low frequency noise level within the room as the overall noise level has been reduced.
Based on the 12mm laminated glass on-third octave band performance, the spectrum of the calculated noise level within the proposed bedrooms are shown in Appendix D.
The low frequency content of the calculated levels within the bedrooms are such that they are likely to be audible and annoying to occupants within the proposed apartments. It is considered likely that the neighbouring nightclub noise emissions will require reduction for noise levels within the proposed apartment to comply with the Town of Vincent Sound Attenuation Policy.
Given the noise emissions associated with the neighbouring nightclub have been conservatively estimated to significantly exceed the allowable noise levels in accordance with the Environmental Protection (Noise) Regulations 1997, a reduction in noise emissions from the nightclub would be considered a fair compromise.
ITEM 9.1.4
Architectural
Lift Design
Car Stackers
Surveying
Mayes Drafting
Grant Elevators
Klaus Carparking Systems
De Nada Engineering Surveys
Allan Mayes
Simon Henderson
Rueben Pather
Adam Vincent
0417 942 179
0402 224 440
0410 427 859
0439 992 275
Energy 0412 679 431N.D. Engineering
CONSULTANTS COMPANY CONTACT NUMBER
Nick Della Gatta
Structural
Mechanical
Electrical
Hydraulic
Acoustic
Fire & B.C.A.
Structerre Consulting Engineers
N.D. Engineering
Electrical Design Consultants
Hydraulics Design Australia
Schwanke Consulting
Rob Jarman
Mark McNally
Joe Tilli
Helmut Schwanke
(08) 9205 4500
0412 679 431
0419 922 033
(08) 9225 9305
(08) 9271 1338
0412 679 431N.D. Engineering
CONSULTANTS COMPANY CONTACT NUMBER
Nick Della Gatta
Nick Della Gatta Scale:
Title:
1 = 100 23/11/2012Job No:
Drawn: Date:
A.Mayes
-Rev:Page:A1
Clients:
PERFECT TIME PTY LTDAddress:
LOT 200 (#440-444)WILLIAM STREETPERTH 6000
Size:
domination
construction
Wind:
Site: © Copyright Domination Homes.Reproduction of this plan is illegalwithout the written permission of
DOMINATION HOMES.
Suite 1/43 Westchester RdMALAGA WA 6090
Ph: 92627400 Fax: 92484466 A
Rev Int. Date Item
R:\Drafting\Working Drawings\William St, 440-444, Perth (Carrisa Pty Ltd)\Planning Drawings\Unit addition\WILLIAM ST - Unit Addition Latest.SKF
Allan Mayes Arch DraftsmanPrincipal
address ellenbrook wa 6069 phone (08) 6296 6614mobile 0417 942 179 email [email protected] www.mayesdrafting.com.au
Allan Mayes Arch DraftsmanPrincipal
address ellenbrook wa 6069 phone (08) 6296 6614mobile 0417 942 179 email [email protected] www.mayesdrafting.com.au
20
20
2720
3020
3020
19202720
2720
9230
12560
9230
6000
6000
01
SITE PLAN
PROPOSED ADDITIONSHOWN HATCHED
RL 29.250(REFER PLAN pg.02)
CARPARK
Klaus MultiparkingTrendVario 4300-230(7 bays, 20 cars)
DRIVEWAY
extent of ground floorparking shown dashed
Klaus MultiparkingTrendVario 4300-230(6 bays, 17 cars)
Binspace
12.74
13.16
13.61
13.64
12.65
13.06
13.5413.45
13.61
13.39
13.19
12.97
12.78
12.62
12.79
12.98
13.21
13.45
13.47
13.01
12.60
12.9213.00
13.34
13.32
13.41
13.3713.63
13.7013.23
12.88
13.0
13.0
14.0
14.013.03
12.83
13.13
13.49
13.6713.47
13.75
13.7113.85
13.5113.48
13.27
13.24
12.8612.84
12.84
13.42
13.6713.62
13.5513.17
13.3913.20
13.18
13.33
13.34
13.54
13.37
13.42
13.7513.96
13.87
13.83
14.03
13.93
13.9213.94
14.0514.02
13.92
14.05
14.00
14.08
14.37
14.5914.39
14.38
14.77
14.61
14.43
13.82
14.11
14.19
15.18
15.8315.43
14.9914.88
14.6714.38
14.2214.05
13.9714.13
13.96
14.02
13.78
13.66
WILLIAM STREET
90°90°90°
90° 90°
90°
40.23
12.07
12.07
12.0712.07
SIGN
PCB
GM
CP
2x M
M
IO(c)
IO(b)
IO(a)
40.23
40.23
4
7
12
SEMI-MOUNTABLE KERB
PAVED PATH
0.9m WIRE FENCE (POOR CONDITION)
STEPPING BRICK WALL
13.0
12.76
BALCONY
EXPOSED
PIPE
EXPOSED
PIPE
PCB
BRICK
BUILDING
PAVED PATH
SEMI-MOUNTABLE KERB
TEL
PATH UNDER REPAIR
METAL
SHED
1.8m BRICK WALL
UPPER LEVEL
OVERHANG
SILL RL 17.63
HEAD RL 19.88
2 STOREY
RENDERED
BRICK FLATS
SILL RL 18.32
HEAD RL 19.88
SILL RL 19.70
HEAD RL 21.00
SILL RL 19.36
HEAD RL 20.67
BRICK SHED
BRICK & METAL
BUILDING
FLLOR RL14.76
SILL RL 19.36
HEAD RL 20.67
2 STOREY
BRICK BUILDING
FLOOR RL 12.93NOTE:
APPROXIMATE AHD LEVEL DERIVED
FROM SEWERAGE MANHOLES
0336, 6015, X 3283 & W 8412.
TOP OF PARAPET
WALL RL 20.21
EVE RL 21.94
EVE RL 21.60
EVE RL 21.54
PARAPET
WALL RL16.90
TOP OF BRICK
WALL RL 16.46
TOP OF WALL
RL 17.51
TOP OF BRICK WALL RL 17.16
TOP OF BRICK
WALL RL 17.52
TOP OF WALL
RL 16.98
TOP OF WALL
RL 16.38
TOP OF PARAPET
WALL RL 21.18
TOP OF PARAPET
WALL RL 17.67
TOP OF PARAPET
WALL RL 19.17
DATUM NAIL 13.05
APPROX AHD
(GRAVEL)
GM
TEL
LP
TEL
G
LP
N
OVERSHADOWINGAREA - 933.648m²
ITEM 9.1.4
3850 2410 6060 1710 14820
Architectural
Lift Design
Car Stackers
Surveying
Mayes Drafting
Grant Elevators
Klaus Carparking Systems
De Nada Engineering Surveys
Allan Mayes
Simon Henderson
Rueben Pather
Adam Vincent
0417 942 179
0402 224 440
0410 427 859
0439 992 275
Energy 0412 679 431N.D. Engineering
CONSULTANTS COMPANY CONTACT NUMBER
Nick Della Gatta
Structural
Mechanical
Electrical
Hydraulic
Acoustic
Fire & B.C.A.
Structerre Consulting Engineers
N.D. Engineering
Electrical Design Consultants
Hydraulics Design Australia
Schwanke Consulting
Rob Jarman
Mark McNally
Joe Tilli
Helmut Schwanke
(08) 9205 4500
0412 679 431
0419 922 033
(08) 9225 9305
(08) 9271 1338
0412 679 431N.D. Engineering
CONSULTANTS COMPANY CONTACT NUMBER
Nick Della Gatta
Nick Della Gatta Scale:
Title:
1 = 100 23/11/2012Job No:
Drawn: Date:
A.Mayes
-Rev:Page:A1
Clients:
PERFECT TIME PTY LTDAddress:
LOT 200 (#440-444)WILLIAM STREETPERTH 6000
Size:
domination
construction
Wind:
Site: © Copyright Domination Homes.Reproduction of this plan is illegalwithout the written permission of
DOMINATION HOMES.
Suite 1/43 Westchester RdMALAGA WA 6090
Ph: 92627400 Fax: 92484466 A
Rev Int. Date Item
R:\Drafting\Working Drawings\William St, 440-444, Perth (Carrisa Pty Ltd)\Planning Drawings\Unit addition\WILLIAM ST - Unit Addition Latest.SKF
Allan Mayes Arch DraftsmanPrincipal
address ellenbrook wa 6069 phone (08) 6296 6614mobile 0417 942 179 email [email protected] www.mayesdrafting.com.au
Allan Mayes Arch DraftsmanPrincipal
address ellenbrook wa 6069 phone (08) 6296 6614mobile 0417 942 179 email [email protected] www.mayesdrafting.com.au
Velux sky lights
Velux sky lights
Velux sky lights
Velux sky lights
Velux sky lights
Velux sky lights
28850 overall
59524101370405011202410172530012102001250121011401210125020018104003850
28850 overall
3850 3820 2300 18880
3850 955 2410 455 2300 770 2410 420 1500 785 3430 4050 2510 2410 595
24100 overall
2700
18100
300
800
1900
300
2700
300
4385
2410
735
1210
620
1210
735
2410
4385
300
800
1900
1900
800
6850
5000
6550
300
2700
24100 overall
1900
800
1550
4050
1000250
3000
1000
10002501000
4050
1250
300
2700
610 530
2720
1920 2720
3020
6000
6000
3020
2720
9230
12560
9230
20
20
02
FLOOR PLAN
roofbelow
roofbelow
roofbelow
roofbelow
STAIR
LIFT
BALCONY
BALCONY
BALCONY
1050 highbalustrading
1050 highbalustrading
Sh-05
1600 high screen wall
ceiling @ 28c
ceiling @ 28c
Sh-05
A
LIVING
ptryohcfr rec
gas hp,ubo& r/hood
ptry
ohc
fr rec
gas hp,ubo &r/hood
FHR
BED 2ceiling @ 32c
BED 2
ceiling @ 32c
LIVING
ptry
ohc
fr rec
gas hp,ubo &r/hood
ptry
ohc
fr rec
gas hp,ubo &r/hood
BED 1
linen
shr
ENSWIR
BED 1
BED 1
BED 2
LIVING
LIVING
BED 2
BED 1
ENS
ENS
WIR
WIR
LDY
LDY
linen
linen
robe
robe
robe
robe
5.02 x 6.05
3.07 x 2.96
3.80 x 4.20
4.20 x 6.98
3.10 x 2.90
4.40 x 3.50
4.40 x 3.50
3.10 x 2.90
4.20 x 6.99
4.50 x 6.35
3.34 x 3.16
DUCT
COMMS
STORE 1 STORE 2
STORE 4STORE 3
ENSWIR
4.14 x 3.90
4.0m²4.0m²
4.0m² 4.0m²
ENS
PDR
BATH
BATH
BATH
ceiling @ 32c
ceiling @ 32c
ceiling @ 32c
ceiling @ 32c
ceiling @ 32c
ceiling @ 32c
ceiling @ 32c
ceiling @ 32c
720
720
720
720
820
820
920
720
720
820
720
820
820
820
720
720
820
820
820
720
720
720
820
820
820
820820
820
3/720
920
920
920
920
shrwc
vb
wc
wcvb
vb
shr
shr
shr
vb
wc
shr
wc
wc vb
tr
wmrec
wmrec
wmrec
wmrec
wc
vb
vb wcshr
shr
wc
vb
A
1200 high screen wall
1200 high screen wall
steel framed metaldeck roof over
steel framed metaldeck roof over
BALCONY
1200 high screen wall
1600 high screen wall
1200 high screen wall
1200 high screen wall
1200 high screen wall
1200 high screen wall
1200 high screen wall
1200 high screen wall
1200 high screen wall
Sh-05
BSh-05
B
box gutter over
box gutter over box gutter over
box gutter over
18c-7½b
08c-5bobs
18c-5b18c-10b SD-4050 25c-10b
10c-10b
14c-5b
obs
14c-5b
obs
10c-10b
25c-10bSD-405018c-10b18c-10b10c-10b
SD-4050
25c-1000
25c-1000
25c-3000
25c-1000
SD-4050
08c-5bobs
08c-1500obs
12c-2½bobs
skylight
skylight
skylight
skylight
skylight
skylight
2/520
12c-2½bobs
25c-2½b 5c-1610 25c-2½b
25c-2½b 5c-1610 25c-2½b
glazing
skylight
lin
3/820
extent of selectedwall lining & flush doorframes shown dashed
RL= 29.250
RL= 29.250
RL= 29.250
RL= 29.250
AREAS:
UNIT 1floor area: 94.514m²balcony: 20.405m² total: 114.919m²
UNIT 2floor area: 102.431m²balcony: 20.405m²total: 122.836m²
UNIT 3floor area: 89.652m²balcony: 29.490m²total: 119.142m²
UNIT 4floor area: 89.652m²balcony: 29.490m²total: 119.142m²
Area of Units: 476.039m²Common Area: 68.193m²
TOTAL AREA: 544.232m²
UNIT 1
UNIT 2 UNIT 4
UNIT 3
1.4.
3.2.
louveredawning
louveredawning
louveredawning
ITEM 9.1.4
Architectural
Lift Design
Car Stackers
Surveying
Mayes Drafting
Grant Elevators
Klaus Carparking Systems
De Nada Engineering Surveys
Allan Mayes
Simon Henderson
Rueben Pather
Adam Vincent
0417 942 179
0402 224 440
0410 427 859
0439 992 275
Energy 0412 679 431N.D. Engineering
CONSULTANTS COMPANY CONTACT NUMBER
Nick Della Gatta
Structural
Mechanical
Electrical
Hydraulic
Acoustic
Fire & B.C.A.
Structerre Consulting Engineers
N.D. Engineering
Electrical Design Consultants
Hydraulics Design Australia
Schwanke Consulting
Rob Jarman
Mark McNally
Joe Tilli
Helmut Schwanke
(08) 9205 4500
0412 679 431
0419 922 033
(08) 9225 9305
(08) 9271 1338
0412 679 431N.D. Engineering
CONSULTANTS COMPANY CONTACT NUMBER
Nick Della Gatta
Nick Della Gatta Scale:
Title:
1 = 100 23/11/2012Job No:
Drawn: Date:
A.Mayes
-Rev:Page:A1
Clients:
PERFECT TIME PTY LTDAddress:
LOT 200 (#440-444)WILLIAM STREETPERTH 6000
Size:
domination
construction
Wind:
Site: © Copyright Domination Homes.Reproduction of this plan is illegalwithout the written permission of
DOMINATION HOMES.
Suite 1/43 Westchester RdMALAGA WA 6090
Ph: 92627400 Fax: 92484466 A
Rev Int. Date Item
R:\Drafting\Working Drawings\William St, 440-444, Perth (Carrisa Pty Ltd)\Planning Drawings\Unit addition\WILLIAM ST - Unit Addition Latest.SKF
Allan Mayes Arch DraftsmanPrincipal
address ellenbrook wa 6069 phone (08) 6296 6614mobile 0417 942 179 email [email protected] www.mayesdrafting.com.au
Allan Mayes Arch DraftsmanPrincipal
address ellenbrook wa 6069 phone (08) 6296 6614mobile 0417 942 179 email [email protected] www.mayesdrafting.com.au
ELEVATIONS 1
25.870
29.250
25.870
29.250
natural ground line
16.925 16.925
17.672sign and light (street address)
25.87025.870
sign and lightsign and light
ELEVATION 4 (Front, West)
RL=29.25fourth floor level
298
3252
298
3252
298
4472
first floor level
second floor level
third floor level RL=25.37
RL=21.82
RL=18.27
3550
3550
4770
ground floor level RL=13.50
shop 3 & 4 floor level RL=13.00
3440
pump room floor level RL=10.06
500
200
2740
pump room ceiling level
3582
2743
ceiling level
sign and light sign and light
EDCBA
approx. neighbouring brick fence / building line
natural ground line
22.420
18.850
22.720 22.72022.420
18.850
15.930
17.520
ELEVATION 2 (Rear, East)
RL=29.25fourth floor level
298
3252
298
3252
298
4472
first floor level
second floor level
third floor level RL=25.37
RL=21.82
RL=18.27
3550
3550
4770
ground floor level RL=13.50
shop 3 & 4 floor level RL=13.00
3440
pump room floor level RL=10.06
500
200
2740
pump room ceiling level
3582
19.170 19.120
ABCDE
ceiling level
2743
03
PROPOSED ADDITIONSHOWN HATCHED
PROPOSED ADDITIONSHOWN HATCHED
33.193 33.193
33.193 33.193
3880
3880
298
298
louveredawning
louveredawning
louveredawning
ITEM 9.1.4
Architectural
Lift Design
Car Stackers
Surveying
Mayes Drafting
Grant Elevators
Klaus Carparking Systems
De Nada Engineering Surveys
Allan Mayes
Simon Henderson
Rueben Pather
Adam Vincent
0417 942 179
0402 224 440
0410 427 859
0439 992 275
Energy 0412 679 431N.D. Engineering
CONSULTANTS COMPANY CONTACT NUMBER
Nick Della Gatta
Structural
Mechanical
Electrical
Hydraulic
Acoustic
Fire & B.C.A.
Structerre Consulting Engineers
N.D. Engineering
Electrical Design Consultants
Hydraulics Design Australia
Schwanke Consulting
Rob Jarman
Mark McNally
Joe Tilli
Helmut Schwanke
(08) 9205 4500
0412 679 431
0419 922 033
(08) 9225 9305
(08) 9271 1338
0412 679 431N.D. Engineering
CONSULTANTS COMPANY CONTACT NUMBER
Nick Della Gatta
Nick Della Gatta Scale:
Title:
1 = 100 23/11/2012Job No:
Drawn: Date:
A.Mayes
-Rev:Page:A1
Clients:
PERFECT TIME PTY LTDAddress:
LOT 200 (#440-444)WILLIAM STREETPERTH 6000
Size:
domination
construction
Wind:
Site: © Copyright Domination Homes.Reproduction of this plan is illegalwithout the written permission of
DOMINATION HOMES.
Suite 1/43 Westchester RdMALAGA WA 6090
Ph: 92627400 Fax: 92484466 A
Rev Int. Date Item
R:\Drafting\Working Drawings\William St, 440-444, Perth (Carrisa Pty Ltd)\Planning Drawings\Unit addition\WILLIAM ST - Unit Addition Latest.SKF
Allan Mayes Arch DraftsmanPrincipal
address ellenbrook wa 6069 phone (08) 6296 6614mobile 0417 942 179 email [email protected] www.mayesdrafting.com.au
Allan Mayes Arch DraftsmanPrincipal
address ellenbrook wa 6069 phone (08) 6296 6614mobile 0417 942 179 email [email protected] www.mayesdrafting.com.au
neighbouring gound level
7654321
25.870
22.420
18.850
natural ground line
17.672
16.925
boundary line
boundary line
existingneighbouringretaining
new cut and retaining
25.870
22.420
18.850
natural ground line
AFS wall system set 20mm from boundary
boundary line
boundary line
existingneighbouringbrick fence
existingneighbouringretaining
neighbouring gound level
17.520
new cut and retaining
ELEVATION 3 (Side, North)
ELEVATION 1 (Side, South)
AFS wall system set 20mm from boundary
17.672
16.925
RL=29.25fourth floor level
298
3252
298
3252
298
4472
first floor level
second floor level
third floor level RL=25.37
RL=21.82
RL=18.27
3550
3550
4770
ground floor level RL=13.50
shop 3 & 4 floor level RL=13.00
3440
pump room floor level RL=10.06
500
200
2740
pump room ceiling level
3582
RL=29.25fourth floor level
298
3252
298
3252
298
4472
first floor level
second floor level
third floor level RL=25.37
RL=21.82
RL=18.27
3550
3550
4770
ground floor level RL=13.50
shop 3 & 4 floor level RL=13.00
3440
pump room floor level RL=10.06
500
200
2740
pump room ceiling level
3582
2743
ceiling level
ceiling level
2743
1234567
04
ELEVATIONS 2
PROPOSED ADDITIONSHOWN HATCHED
PROPOSED ADDITIONSHOWN HATCHED
33.193 33.193
33.193 33.193
3880
3880
298
298
ITEM 9.1.4
Architectural
Lift Design
Car Stackers
Surveying
Mayes Drafting
Grant Elevators
Klaus Carparking Systems
De Nada Engineering Surveys
Allan Mayes
Simon Henderson
Rueben Pather
Adam Vincent
0417 942 179
0402 224 440
0410 427 859
0439 992 275
Energy 0412 679 431N.D. Engineering
CONSULTANTS COMPANY CONTACT NUMBER
Nick Della Gatta
Structural
Mechanical
Electrical
Hydraulic
Acoustic
Fire & B.C.A.
Structerre Consulting Engineers
N.D. Engineering
Electrical Design Consultants
Hydraulics Design Australia
Schwanke Consulting
Rob Jarman
Mark McNally
Joe Tilli
Helmut Schwanke
(08) 9205 4500
0412 679 431
0419 922 033
(08) 9225 9305
(08) 9271 1338
0412 679 431N.D. Engineering
CONSULTANTS COMPANY CONTACT NUMBER
Nick Della Gatta
Nick Della Gatta Scale:
Title:
1 = 100 23/11/2012Job No:
Drawn: Date:
A.Mayes
-Rev:Page:A1
Clients:
PERFECT TIME PTY LTDAddress:
LOT 200 (#440-444)WILLIAM STREETPERTH 6000
Size:
domination
construction
Wind:
Site: © Copyright Domination Homes.Reproduction of this plan is illegalwithout the written permission of
DOMINATION HOMES.
Suite 1/43 Westchester RdMALAGA WA 6090
Ph: 92627400 Fax: 92484466 A
Rev Int. Date Item
R:\Drafting\Working Drawings\William St, 440-444, Perth (Carrisa Pty Ltd)\Planning Drawings\Unit addition\WILLIAM ST - Unit Addition Latest.SKF
Allan Mayes Arch DraftsmanPrincipal
address ellenbrook wa 6069 phone (08) 6296 6614mobile 0417 942 179 email [email protected] www.mayesdrafting.com.au
Allan Mayes Arch DraftsmanPrincipal
address ellenbrook wa 6069 phone (08) 6296 6614mobile 0417 942 179 email [email protected] www.mayesdrafting.com.au
RL=11.20
RL=10.06
RL=10.45
SHOP 01 SHOP 02 SHOP 03 SHOP 04
OFFICE 01 OFFICE 02 OFFICE 03 OFFICE 04
OFFICE 08OFFICE 07OFFICE 06OFFICE 05
OFFICE 12OFFICE 11OFFICE 10OFFICE 09
SECTION A-Ascale 1:100
RL=29.25fourth floor level
298
3252
298
3252
298
4472
first floor level
second floor level
third floor level RL=25.37
RL=21.82
RL=18.27
3550
3550
4770
ground floor level RL=13.50
shop 3 & 4 floor level RL=13.00
3440
pump room floor level RL=10.06
500
200
2740
pump room ceiling level
3582
2743
ceiling level
05
SECTION A-A & B-B
BED 2 PASSAGE LDRY WIR ENSENT
PROPOSED ADDITION SHOWN HATCHED
SECTION B-Bscale 1:100
298
3252
298
3252
298
4472
3550
3550
4770
3440
500
200
2740
3880
2743
RL=29.25
RL=25.37
RL=21.82
RL=18.27
RL=13.50
RL=13.00
RL=10.06
BED 2 FHR COMMS STAIRS KITCHEN
PROPOSED ADDITIONSHOWN HATCHED
33.19333.193 33.193 33.193
3880
298
louveredawning
louveredawning
ITEM 9.1.4