AM-MIO Input-Output Expansion Interface For Use With the AM-3, AE-1000, & AE-2000 Access Control Systems Installation Instructions PRODUCT DESCRIPTION The AM-MIO is an expandable input/output interface designed for use with Linear’s AM-3, AE-1000, & AE-2000 access control systems. Housed in a lockable cabinet, the basic AM-MIO consists of two modules: a power supply module (PSM) and a relay/loop module (RLM). Up to three additional RLM modules can be added to fill the five-position module “rack”. Each RLM module provides six Form “C” (normally open & normally closed) 5-amp relays for outputs and eight supervised loop terminals for inputs. With four RLM modules, the AM-MIO is capable of controlling 24 relay outputs and 32 loop inputs. Each module has a rotary switch to select its unique remote device address. The device address identifies each module to the system. Each module is interconnected to the controller by daisy-chained cables. Pushbuttons on the RLM module are provided for manually triggering each relay for testing. Each relay has a red LED light to show when it’s energized. A two-color red/ green LED on the RLM module displays the status of the loop inputs. If all eight loops are “normal” (not shorted or open) the indicator is green. If any of the eight loops are “abnormal” (shorted or open) the indicator is red. The power supply module distributes power to the RLM module(s). An external 16 VAC transformer powers the supply and provides charging current for a 12-volt backup battery (up to 7 amp/hour capacity). Indicators on the power supply module display its status. The green indicator lights when AC power is present and blinks when AC power is absent. The yellow indicator lights when the backup battery is low. Special power circuitry prevents fully discharging the backup battery. The status of the power supply is checked regularly by the controller. The red DATA indicator lights when data transfers. The red TAMPER indicator lights and the controller is signaled when the optional magnetic tamper switch detects that the cabinet has been opened. CABINET COMPONENTS MODULE FEATURES KEY LOCK INSTALLATION (OPTIONAL) REMOVING MODULES MOUNTING CABINET SETTING DEVICE ADDRESSES CONNECTING MODULES INSTALLING MODULES CONNECTING TAMPER SWITCH (OPTIONAL) CONNECT TO ACCESS CONTROLLER (760) 438-7000 USA & Canada (800) 421-1587 & (800) 392-0123 Toll Free FAX (800) 468-1340 www.linearcorp.com POWER SUPPLY MODULE (PSM) NOTE: ILLUSTRATION SHOWS FOUR RELAY/LOOP MODULES, ONLY ONE MODULE IS INCLUDED WITH THE AM-MIO RELAY/LOOP MODULES (RLM) (FOUR MODULES MAXIMUM) BACKUP BATTERY 12 VOLT 7 AMP/HOUR MAXIMUM (NOT INCLUDED) MODULE MOUNTING RACKS CAREFULLY ROUTE THE BATTERY LEADS UNDER MODULE RACK AS SHOWN 1 2 SLIDE MODULES OUT OF THE RACK PSM RLM 1 2 3 PLACE COVER ON CARPET AND PUNCH OUT KEY LOCK KNOCKOUT INSERT LOCK INTO COVER TIGHTEN NUT RELAY/LOOP MODULE (RLM) POWER SUPPLY MODULE (PSM) BACKUP BATTERY LEADS DEVICE ADDRESS SELECTOR DATA POWER SUPPLY STATUS INDICATORS TAMPER LOW BATTERY AC POWER TAMPER SWITCH CONNECTOR MODULE CONNECTOR CONTROLLER CONNECTOR POWER TERMINALS AUXILIARY PBUS TERMINALS RELAY STATUS INDICATORS LOOP STATUS INDICATOR DEVICE ADDRESS SELECTOR MODULE CONNECTORS RELAY TRIGGER PUSHBUTTONS RELAY OUTPUT TERMINALS LOOP INPUT TERMINALS USE THE CABINET BOTTOM AS A TEMPLATE TO MARK THE FOUR KEYHOLE MOUNTING HOLES FOR RECESSED WIRING, MARK WIRING SLOT, THEN CUT OUT HOLE WITH DRYWALL SAW FOR CONDUIT WIRING, REMOVE ANY CABINET KNOCKOUTS BEFORE MOUNTING THE CABINET USE THE APPROPRIATE HARDWARE TO MOUNT THE CABINET NOTE: PSM DEFAULT ADDRESS IS "5" NOTE: RLM DEFAULT ADDRESS IS "4" THE ARROW IN THE SELECTOR SWITCH SLOT POINTS TO THE ADDRESS NUMBER (ADDRESS NUMBERS 1-6 ARE VALID) SET EACH MODULE TO A DIFFERENT DEVICE ADDRESS (ONLY REQUIRED IF ADDRESS OTHER THAN DEFAULT IS DESIRED) RELAY/LOOP MODULE POWER SUPPLY MODULE CONNECT POWER SUPPLY TO RELAY/LOOP MODULE WITH THE 10-WIRE CABLE TO KEEP THE BATTERY LEADS AWAY FROM THE POWER SUPPLY HEAT SINK, ROUTE THE BATTERY LEADS UNDER MODULE RACK AS SHOWN 1 2 3 SLIDE MODULES INTO RACK PRESS THE MODULES IN UNTIL THEY SNAP INTO PLACE PSM RLM 1 2 3 REMOVE THE OPTIONAL JUMPER FROM THE TAMPER SWITCH CONNECTOR INSTALL THE TAMPER SWITCH IN THE BOTTOM CORNER OF CABINET AND CONNECT THE WIRE TO THE TAMPER SWITCH CONNECTOR ATTACH THE MAGNET TO THE CABINET COVER SO IT WILL ALIGN WITH THE TAMPER SWITCH WHEN THE COVER IS CLOSED PLUG CABLE FROM AM-MIO PSM CONTROLLER CONNECTOR INTO THE CONTROLLER'S AM-MIO INTERFACE CONNECTOR (MODEL AM-3 CONTROLLER SHOWN) TO AM-MIO PSM OPTIONAL: USE THE PSM AUXILIARY PBUS TERMINALS TO CONNECT TO THE CONTROLLER'S AUXILIARY PBUS TERMINALS. REFERENCE THE PSM WIRING DIAGRAM. CABLE TYPE IS BELDEN 9931 (300 FEET MAX. CABLE RUN) OR WEICO 9405 (500 FEET MAX. CABLE RUN).

Transcript of AM-MIO - Nortek Security & Control · The AM-MIO is an expandable input/output interface designed...

Page 1: AM-MIO - Nortek Security & Control · The AM-MIO is an expandable input/output interface designed for use with Linear’s AM-3, AE-1000, & AE-2000 access control systems. Housed in

AM-MIOInput-Output Expansion InterfaceFor Use With the AM-3, AE-1000, & AE-2000 Access Control Systems

Installation Instructions

PRODUCT DESCRIPTIONThe AM-MIO is an expandable input/output interface designed for use with Linear’s AM-3, AE-1000, & AE-2000 access control systems. Housed in a lockable cabinet, the basic AM-MIO consists of two modules: a power supply module (PSM) and a relay/loop module (RLM). Up to three additional RLM modules can be added to fill the five-position module “rack”. Each RLM module provides six Form “C” (normally open & normally closed) 5-amp relays for outputs and eight supervised loop terminals for inputs. With four RLM modules, the AM-MIO is capable of controlling 24 relay outputs and 32 loop inputs. Each module has a rotary switch to select its unique remote device address. The device address identifies each module to the system. Each module is interconnected to the controller by daisy-chained cables.Pushbuttons on the RLM module are provided for manually triggering each relay for testing. Each relay has a red LED light to show when it’s energized. A two-color red/green LED on the RLM module displays the status of the loop inputs. If all eight loops are “normal” (not shorted or open) the indicator is green. If any of the eight loops are “abnormal” (shorted or open) the indicator is red.The power supply module distributes power to the RLM module(s). An external 16 VAC transformer powers the supply and provides charging current for a 12-volt backup battery (up to 7 amp/hour capacity). Indicators on the power supply module display its status. The green indicator lights when AC power is present and blinks when AC power is absent. The yellow indicator lights when the backup battery is low. Special power circuitry prevents fully discharging the backup battery. The status of the power supply is checked regularly by the controller. The red DATA indicator lights when data transfers. The red TAMPER indicator lights and the controller is signaled when the optional magnetic tamper switch detects that the cabinet has been opened.

CABINET COMPONENTS

MODULE FEATURES KEY LOCK INSTALLATION (OPTIONAL) REMOVING MODULES

MOUNTING CABINET SETTING DEVICE ADDRESSES CONNECTING MODULES

INSTALLING MODULES CONNECTING TAMPER SWITCH (OPTIONAL) CONNECT TO ACCESS CONTROLLER

(760) 438-7000USA & Canada (800) 421-1587 & (800) 392-0123

Toll Free FAX (800) 468-1340www.linearcorp.com

PRINTER’S INSTRUCTIONS:INSTR,INSTL,AM-MIO - LINEAR P/N: 218307 B - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000” X 8.500” - SCALE: 1-1 - SIDE 1 OF 2

POWERSUPPLYMODULE(PSM)

NOTE: ILLUSTRATION SHOWS FOURRELAY/LOOP MODULES, ONLY ONEMODULE IS INCLUDED WITH THE AM-MIO

RELAY/LOOP MODULES (RLM)(FOUR MODULES MAXIMUM)

BACKUP BATTERY12 VOLT 7 AMP/HOURMAXIMUM(NOT INCLUDED)

MODULEMOUNTINGRACKS

CAREFULLY ROUTE THE BATTERYLEADS UNDER MODULE RACKAS SHOWN

1

2SLIDE MODULES OUTOF THE RACK

PSM RLM

1

2

3

PLACE COVER ONCARPET AND PUNCHOUT KEY LOCKKNOCKOUT

INSERT LOCK INTO COVER

TIGHTEN NUT

RELAY/LOOPMODULE (RLM)

POWER SUPPLYMODULE (PSM)

BACKUPBATTERY

LEADS

DEVICEADDRESSSELECTOR

DATA

POWER SUPPLYSTATUS

INDICATORS

TAMPER

LOW BATTERY

AC POWER TAMPERSWITCH

CONNECTOR

MODULECONNECTOR

CONTROLLERCONNECTOR

POWERTERMINALS

AUXILIARYPBUS

TERMINALS

RELAYSTATUS

INDICATORS

LOOP STATUSINDICATOR

DEVICE ADDRESSSELECTOR

MODULECONNECTORS

RELAY TRIGGERPUSHBUTTONS

RELAYOUTPUT

TERMINALS

LOOPINPUT

TERMINALS

USE THE CABINET BOTTOM AS A TEMPLATE TO MARK THE FOUR KEYHOLE MOUNTING HOLES

FOR RECESSED WIRING, MARK WIRING SLOT,THEN CUT OUT HOLEWITH DRYWALL SAW

FOR CONDUIT WIRING,REMOVE ANY CABINETKNOCKOUTS BEFOREMOUNTING THE CABINET

USE THE APPROPRIATEHARDWARE TO MOUNTTHE CABINET

NOTE: PSM DEFAULT ADDRESS IS "5"

NOTE: RLM DEFAULT ADDRESS IS "4"

THE ARROW IN THESELECTOR SWITCHSLOT POINTS TOTHE ADDRESSNUMBER (ADDRESSNUMBERS 1-6 AREVALID)

SET EACH MODULETO A DIFFERENTDEVICE ADDRESS(ONLY REQUIRED IFADDRESS OTHERTHAN DEFAULT ISDESIRED)

RELAY/LOOPMODULE

POWER SUPPLYMODULE

CONNECT POWER SUPPLYTO RELAY/LOOP MODULEWITH THE 10-WIRE CABLE

TO KEEP THE BATTERY LEADSAWAY FROM THE POWER SUPPLYHEAT SINK, ROUTE THE BATTERYLEADS UNDER MODULE RACKAS SHOWN

1

2

3

SLIDE MODULES INTO RACK

PRESS THE MODULES IN UNTILTHEY SNAP INTO PLACE

PSM RLM

1

2

3

REMOVE THE OPTIONAL JUMPER FROM THE TAMPER SWITCHCONNECTOR

INSTALL THE TAMPER SWITCHIN THE BOTTOM CORNER OFCABINET AND CONNECT THEWIRE TO THE TAMPERSWITCH CONNECTOR

ATTACH THE MAGNET TO THE CABINETCOVER SO IT WILL ALIGN WITH THETAMPER SWITCH WHEN THE COVER ISCLOSED

PLUG CABLE FROM AM-MIO PSM CONTROLLERCONNECTOR INTO THE CONTROLLER'S AM-MIOINTERFACE CONNECTOR (MODEL AM-3 CONTROLLER SHOWN)

TO AM-MIO PSM

OPTIONAL: USE THE PSM AUXILIARY PBUS TERMINALS TOCONNECT TO THE CONTROLLER'S AUXILIARY PBUS TERMINALS.REFERENCE THE PSM WIRING DIAGRAM. CABLE TYPE ISBELDEN 9931 (300 FEET MAX. CABLE RUN) OR WEICO 9405(500 FEET MAX. CABLE RUN).

Page 2: AM-MIO - Nortek Security & Control · The AM-MIO is an expandable input/output interface designed for use with Linear’s AM-3, AE-1000, & AE-2000 access control systems. Housed in

CONNECT RELAY OUTPUTS CONNECT LOOP INPUTS CONNECT AC POWER

CONNECT BACKUP BATTERY TEST RELAYS TEST LOOPS

WIRING DIAGRAM

TEST SYSTEM LINEAR LIMITED WARRANTYThis Linear product is warranted against defects in material and workmanship for twenty four (24) months. The Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fitness, are valid only until Warranty Expiration Date as labeled on the product. This Linear LLC Warranty is in lieu of all other warranties express or implied.All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Service at 1-800-421-1587 for an RPA# and other important details.

IMPORTANT !!!Linear radio controls provide a reliable communications link and fill an important need in portable wireless signalling. However, there are some limitations which must be observed.• For U.S. installations only: The radios are required to comply with FCC

Rules and Regulations as Part 15 devices. As such, they have limited transmitter power and therefore limited range.

• A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies, regardless of code settings.

• Changes or modifications to the device may void FCC compliance.• Infrequently used radio links should be tested regularly to protect

against undetected interference or fault.• A general knowledge of radio and its vagaries should be gained prior

to acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users.

Copyright © 2004 Linear LLC 218307 B

PRINTER’S INSTRUCTIONS:INSTR,INSTL,AM-MIO - LINEAR P/N: 218307 B - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000” X 8.500” - SCALE: 1-1 - SIDE 2 OF 2

N.O.

1

COM

2

N.C.

3

N.O.

4

COM

5

N.C.

6

N.O.

7

COM

8

N.C.

9

N.O.

10

COM

11

N.C.

12

N.O.

13

COM

14

N.C.

15

N.O.

16

COM

17

N.C.

18

CHANNEL 1 CHANNEL 2 CHANNEL 3

CHANNEL 4 CHANNEL 5 CHANNEL 6

CONNECT RELAYOUTPUTS TO THECONTROLLEDDEVICES

RELAY RATING:5 AMPS @14 VDCMAXIMUM

LOOP1

1

COM

2

LOOP2

3

LOOP3

4

COM

5

LOOP4

6

LOOP5

7

COM

8

LOOP6

9

LOOP7

10

COM

11

LOOP8

12

2.2K 2.2K 2.2K 2.2K

2.2K 2.2K 2.2K 2.2K

CONNECT ANY INPUTS TO THELOOP INPUT TERMINALS

EACH LOOP INPUT CAN BETRIGGERED WITH A NORMALLYOPEN OR NORMALLY CLOSEDSWITCH

ALL LOOP INPUTS MUST BETERMINATED WITH A 2.2KEND-OF-LINE RESISTOR

EXAMPLE OF LOOPS 1-4WITH NORMALLYCLOSED SWITCHES

EXAMPLE OF LOOPS 5-8WITH NORMALLYOPEN SWITCHES

ACIN1

ACIN2

EARTHGND

3

DATAGND

4

POWERTERMINALS

16 VAC, 24 VA MIN.POWER

TRANSFORMER

UNIFIEDEARTHGROUND

CONNECT 16 VACPOWER FROM PLUG-INTRANSFORMER TOPOWER TERMINALS1 & 2

CONNECT A GOODEARTH GROUND TOPOWER TERMINAL 3

NOTE: DATA GROUNDTERMINAL IS USED ONLYWHEN CONNECTINGTO THE CONTROLLERTHROUGH THECONTROLLER AUXILIARYPBUS TERMINALS

PLACE THE BACKUPBATTERY IN THE CABINET

CONNECT THE RED LEAD TO BATTERY POSITIVE (+)CONNECT THE BLACK LEAD TO BATTERY NEGATIVE (-)

PRESS THE RELAYTRIGGER BUTTONSTO TEST EACH RELAYCONNECTED

THE RELAY STATUSINDICATOR WILL

LIGHT WHEN THERELAY IS ENERGIZED

CAUTION!DEVICES CONNECTED TO

THE RELAYS WILL ACTIVATE

WATCH THE LOOPSTATUS INDICATORWHILE TESTING THE LOOPS

GREEN = ALL LOOPS NORMALRED = ANY LOOP OPEN OR SHORTED

LOOP1

COM LOOP2

LOOP3

COM LOOP4

2.2K 2.2K 2.2K 2.2K

4 5 61 2 3

LOOP5

COM LOOP6

LOOP7

COM LOOP8

2.2K 2.2K 2.2K 2.2K

10 11 127 8 9

CHANNEL 2 CHANNEL 3

7 8 94 5 6

16 17 1813 14 15

N.O.CHANNEL 1

2 31

11 1210

COM N.C. N.O. COM N.C. N.O. COM N.C.

CHANNEL 5 CHANNEL 6N.O.

CHANNEL 4COM N.C. N.O. COM N.C. N.O. COM N.C.

POWER TERMINALSACIN

ACIN

EARTHGND

DATAGND

DAT1 DAT0 DVAL PCLKAUXILIARY PBUS TERMINALS

RELAY OUTPUT TERMINALS

RELAY OUTPUT TERMINALS

LOOP INPUT TERMINALS

LOOP INPUT TERMINALS

ALL LOOP INPUTS MUST BETERMINATED WITH A 2.2KEND-OF-LINE RESISTOR

CONTROLLED DEVICE "4" CONTROLLED DEVICE "5" CONTROLLED DEVICE "6"

CONTROLLED DEVICE "1" CONTROLLED DEVICE "2" CONTROLLED DEVICE "3"16 VAC, 24 VA

MINIMUMTRANSFORMER EARTH

GROUNDSTAKE

CONTROLLER PBUS TERMINALS

6 7 85

4321

POWER SUPPLYMODULE (PSM)

RELAY/LOOPMODULE (RLM)

AM-MIO RLM WIRING DIAGRAMAM-MIO PSM WIRING DIAGRAM

12 VDCBACKUPBATTERY

+ RE

D W

IRE

- BLA

CK W

IRE

NOTE: OPTIONAL AM-MIO PSM TO CONTROLLER WIRING SHOWN WHEN NOT USING THE INCLUDED CABLE

1. PROGRAM THE ACCESSCONTROL SYSTEM. BESURE TO PROGRAM THESYSTEM FOR THE DEVICEADDRESS OF EACH OF THEAM-MIO MODULES.

2. USE ENTRY CODES ORTRANSMITTERS TO TESTACTIVATE EACH OF THEAM-MIO OUTPUTS

3. TEST TO SEE IF EACH OFTHE AM-MIO LOOP INPUTS(IF USED) ARE RECOGNIZEDBY THE ACCESS CONTROLSYSTEM