Aluminum Conductor, Compressed Hard-drawn, EC-1350 · PDF fileCONDUMEX VULCANEL CABLE ......

16
CONDUMEX VULCANEL CABLE Primary URD 15 KV 100% Insulation Level 175 Mils EPR Insulation eliminating unequal electrical stress. loss, chemical resistance. Specifications: Aluminum conductors are also available strand-filled. ICEA S-94-649; AEIC CS 8 Short Circuit - 250 C O Dimensions and weights are nominal, and subject to standard industry tolerances. Normal Operation - 90 C; Emergency Overload - 130 C O O Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations. 1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core, Maximum Conductor Temperatures: Application: Features: 2. Ethylene Propylene Rubber (EPR) insulation offers: excellent heat, moisture and corona resistance; electrical stability under stress; low dielectric Aluminum Conductor, Compressed Hard-drawn, EC-1350 Alloy Conductor AWG or MCM Copper Neutral (Full) Diameter (Inches) Weight (Pounds) Stranding Conductor Conductor Size AWG (Solid) Number of Wires Over Insulation Over Neutral Wires Over Insul. Shield Over Encaps. Jkt. Concentric Neutral Total No Jacket Total With Jacket 2 1 1/0 2/0 3/0 4/0 7 wire 19 wire 19 wire 19 wire 19 wire 19 wire 10 13 16 20 16 20 14 14 14 12 12 12 0.29 0.33 0.37 0.42 0.47 0.53 0.69 0.73 0.77 0.82 0.87 0.93 0.75 0.80 0.84 0.88 0.93 0.99 0.88 0.93 0.97 1.01 1.10 1.15 0.98 1.03 1.07 1.11 1.20 1.26 62.2 79.0 98.8 124.6 157.5 198.2 132.1 172.0 212.0 273.0 338.0 425.0 455 536 615 732 848 1009 518 600 680 810 927 1090 Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds) AWG or MCM Stranding Conductor Conductor Size AWG (Solid) Number of Wires Over Insulation Over Neutral Wires Over Insul. Shield Over Encaps. Jkt. Concentric Neutral Total No Jacket Total With Jacket 2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000 7 wire 19 wire 19 wire 19 wire 19 wire 19 wire 37 wire 37 wire 37 wire 61 wire 61 wire 6 6 6 7 9 11 13 11 16 15 20 14 14 14 14 14 14 14 12 12 10 10 0.29 0.33 0.37 0.42 0.47 0.53 0.57 0.68 0.81 0.99 1.14 0.69 0.73 0.77 0.82 0.87 0.93 0.99 1.09 1.22 1.41 1.57 0.75 0.80 0.84 0.88 0.93 0.99 1.05 1.19 1.33 1.52 1.71 0.88 0.93 0.97 1.01 1.10 1.13 1.17 1.36 1.49 1.72 1.92 0.98 1.03 1.07 1.11 1.20 1.23 1.27 1.46 1.59 1.89 2.03 62.2 79.0 98.8 124.6 157.5 198.2 234.5 327.9 468.3 702.5 936.8 79.3 79.4 79.5 93.1 120.2 152.4 181.0 240.0 350.0 501.7 705.6 403 443 482 552 630 737 849 1111 1442 1959 2524 466 507 547 630 709 818 959 1253 1590 2149 2727

Transcript of Aluminum Conductor, Compressed Hard-drawn, EC-1350 · PDF fileCONDUMEX VULCANEL CABLE ......

CONDUMEX VULCANEL CABLEPrimary URD 15 KV 100% Insulation Level175 Mils EPR Insulation

eliminating unequal electrical stress.

loss, chemical resistance.

Specifications:

Aluminum conductors are also available strand-filled.

ICEA S-94-649; AEIC CS 8

Short Circuit - 250 CO

Dimensions and weights are nominal, and subject to standard industry tolerances.

Normal Operation - 90 C; Emergency Overload - 130 CO O

Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.

1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,

Maximum Conductor

Temperatures:

Application:

Features:

2. Ethylene Propylene Rubber (EPR) insulation offers: excellent heat, moisture and corona resistance; electrical stability under stress; low dielectric

Aluminum Conductor, CompressedHard-drawn, EC-1350 Alloy

ConductorAWG or

MCM

Copper Neutral (Full) Diameter (Inches) Weight (Pounds)

Stranding Conductor ConductorSize

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

2

1

1/0

2/0

3/0

4/0

7 wire

19 wire

19 wire

19 wire

19 wire

19 wire

10

13

16

20

16

20

14

14

14

12

12

12

0.29

0.33

0.37

0.42

0.47

0.53

0.69

0.73

0.77

0.82

0.87

0.93

0.75

0.80

0.84

0.88

0.93

0.99

0.88

0.93

0.97

1.01

1.10

1.15

0.98

1.03

1.07

1.11

1.20

1.26

62.2

79.0

98.8

124.6

157.5

198.2

132.1

172.0

212.0

273.0

338.0

425.0

455

536

615

732

848

1009

518

600

680

810

927

1090

Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)

AWG or

MCMStranding Conductor Conductor

Size

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

2

1

1/0

2/0

3/0

4/0

250

350

500

750

1000

7 wire

19 wire

19 wire

19 wire

19 wire

19 wire

37 wire

37 wire

37 wire

61 wire

61 wire

6

6

6

7

9

11

13

11

16

15

20

14

14

14

14

14

14

14

12

12

10

10

0.29

0.33

0.37

0.42

0.47

0.53

0.57

0.68

0.81

0.99

1.14

0.69

0.73

0.77

0.82

0.87

0.93

0.99

1.09

1.22

1.41

1.57

0.75

0.80

0.84

0.88

0.93

0.99

1.05

1.19

1.33

1.52

1.71

0.88

0.93

0.97

1.01

1.10

1.13

1.17

1.36

1.49

1.72

1.92

0.98

1.03

1.07

1.11

1.20

1.23

1.27

1.46

1.59

1.89

2.03

62.2

79.0

98.8

124.6

157.5

198.2

234.5

327.9

468.3

702.5

936.8

79.3

79.4

79.5

93.1

120.2

152.4

181.0

240.0

350.0

501.7

705.6

403

443

482

552

630

737

849

1111

1442

1959

2524

466

507

547

630

709

818

959

1253

1590

2149

2727

Aluminum Conductor, Compressed

CONDUMEX VULCANEL CABLEPrimary URD 15 KV 133% Insulation Level220 Mils EPR Insulation

Hard-drawn, EC-1350 Alloy

eliminating unequal electrical stress.

loss, chemical resistance.

Specifications:

Aluminum conductors are also available strand-filled.

ICEA S-94-649; AEIC CS 8

Short Circuit - 250 CO

Dimensions and weights are nominal, and subject to standard industry tolerances.

Normal Operation - 90 C; Emergency Overload - 130 CO O

Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.

1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,

Maximum Conductor

Temperatures:

Application:

Features:

2. Ethylene Propylene Rubber (EPR) insulation offers: excellent heat, moisture and corona resistance; electrical stability under stress; low dielectric

ConductorAWG or

MCM

Copper Neutral (Full) Diameter (Inches) Weight (Pounds)

Stranding Conductor ConductorSize

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

2

1

1/0

2/0

3/0

4/0

7 wire

19 wire

19 wire

19 wire

19 wire

19 wire

10

13

16

20

16

20

14

14

14

12

12

12

0.29

0.33

0.37

0.42

0.47

0.53

0.78

0.83

0.87

0.91

0.96

1.02

0.84

0.89

0.93

0.98

1.03

1.12

0.97

1.02

1.06

1.10

1.19

1.29

1.075

1.121

1.161

1.207

1.291

1.386

62.2

79.0

98.8

124.6

157.5

198.2

132.1

172.0

212.0

273.0

338.0

425.0

534

606

691

808

926

1135

603

676

764

895

1015

1228

Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)

AWG or

MCMStranding Conductor Conductor

Size

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

2

1

1/0

2/0

3/0

4/0

250

350

500

750

1000

7 wire

19 wire

19 wire

19 wire

19 wire

19 wire

37 wire

37 wire

37 wire

61 wire

61 wire

6

6

6

7

9

11

13

11

16

15

20

14

14

14

14

14

14

14

12

12

10

10

0.29

0.33

0.37

0.42

0.47

0.53

0.57

0.68

0.81

0.99

1.14

0.78

0.83

0.87

0.91

0.96

1.02

1.08

1.18

1.31

1.51

1.66

0.84

0.89

0.93

0.98

1.03

1.12

1.18

1.29

1.42

1.61

1.81

0.97

1.02

1.06

1.10

1.19

1.27

1.37

1.45

1.58

1.81

2.01

1.075

1.121

1.161

1.207

1.291

1.369

1.469

1.552

1.746

1.980

2.175

62.2

79.0

98.8

124.6

157.5

198.2

234.5

327.9

468.3

702.5

936.8

79.3

79.4

79.5

93.1

120.2

152.4

181.0

240.0

350.0

501.7

705.6

482

513

558

628

708

863

978

1219

1555

2144

2667

551

583

631

715

797

956

1092

1369

1715

2349

2882

eliminating unequal electrical stress.

loss, chemical resistance.

Specifications:

Aluminum conductors are also available strand-filled.

ICEA S-94-649; AEIC CS 8

Short Circuit - 250 CO

Dimensions and weights are nominal, and subject to standard industry tolerances.

Normal Operation - 90 C; Emergency Overload - 130 CO O

Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.

1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,

Maximum Conductor

Temperatures:

Application:

Features:

2. Ethylene Propylene Rubber (EPR) insulation offers: excellent heat, moisture and corona resistance; electrical stability under stress; low dielectric

Aluminum Conductor, Compressed

CONDUMEX VULCANEL CABLEPrimary URD 25 KV 100% Insulation Level260 Mils EPR Insulation

Hard-drawn, EC-1350 Alloy

Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)

AWG or

MCMStranding Conductor Conductor

Size

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

0.33

0.37

0.42

0.47

0.53

0.57

0.68

0.81

0.99

1.14

0.91

0.95

0.99

1.04

1.10

1.16

1.26

1.40

1.59

1.74

0.97

1.01

1.06

1.15

1.21

1.26

1.40

1.50

1.73

1.89

1.10

1.14

1.19

1.31

1.37

1.47

1.53

1.66

1.94

2.09

1.20

1.24

1.29

1.41

1.47

1.57

1.70

1.83

2.10

2.26

79.0

98.8

124.6

157.5

198.2

234.5

327.9

468.3

702.5

936.8

79.4

79.5

93.1

120.2

152.4

181.0

240.0

350.0

501.7

705.6

583

629

706

820

961

1086

1328

1681

2294

2827

664

712

806

923

1068

1229

1500

1865

2528

3072

1

1/0

2/0

3/0

4/0

250

350

500

750

1000

19 wire

19 wire

19 wire

19 wire

19 wire

37 wire

37 wire

37 wire

61 wire

61 wire

6

6

7

9

11

13

11

16

15

20

14

14

14

14

14

14

12

12

10

10

ConductorAWG or

MCM

Copper Neutral (Full) Diameter (Inches) Weight (Pounds)

Stranding Conductor ConductorSize

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

1

1/0

2/0

3/0

4/0

19 wire

19 wire

19 wire

19 wire

19 wire

13

16

13

16

20

14

14

12

12

12

0.33

0.37

0.42

0.47

0.53

0.91

0.95

0.99

1.04

1.10

0.97

1.01

1.06

1.15

1.21

1.10

1.14

1.19

1.31

1.37

1.20

1.24

1.29

1.41

1.47

79.0

96.8

124.6

157.5

198.2

172.0

212.0

273.0

338.0

425.0

676

762

886

1038

1233

757

845

986

1141

1340

Aluminum Conductor, Compressed

CONDUMEX VULCANEL CABLEPrimary URD 35 KV 100% Insulation Level345 Mils EPR Insulation

Hard-drawn, EC-1350 Alloy

eliminating unequal electrical stress.

loss, chemical resistance.

Specifications:

Aluminum conductors are also available strand-filled.

ICEA S-94-649; AEIC CS 8

Short Circuit - 250 CO

Dimensions and weights are nominal, and subject to standard industry tolerances.

Normal Operation - 90 C; Emergency Overload - 130 CO O

Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.

1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,

Maximum Conductor

Temperatures:

Application:

Features:

2. Ethylene Propylene Rubber (EPR) insulation offers: excellent heat, moisture and corona resistance; electrical stability under stress; low dielectric

ConductorAWG or

MCM

Copper Neutral (Full) Diameter (Inches) Weight (Pounds)

Stranding Conductor ConductorSize

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

1/0

2/0

3/0

4/0

19 wire

19 wire

19 wire

19 wire

16

13

16

20

14

12

12

12

0.37

0.42

0.47

0.53

1.12

1.17

1.22

1.26

1.23

1.27

1.32

1.38

1.35

1.40

1.48

1.54

1.46

1.50

1.59

1.71

98.8

124.6

157.5

198.2

212.0

273.0

338.0

425.0

968

1105

1236

1433

1068

1224

1356

1558

Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)

AWG or

MCMStranding Conductor Conductor

Size

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

98.8

124.6

157.5

198.2

234.5

327.9

468.3

702.5

936.8

79.5

93.1

120.2

152.4

181.0

240.0

350.0

501.7

705.6

835

925

1018

1161

1301

1558

2003

2590

3143

935

10444

1138

1286

1484

1752

2213

2850

3415

0.37

0.42

0.47

0.53

0.57

0.68

0.81

0.99

1.14

1.12

1.17

1.22

1.28

1.33

1.44

1.57

1.76

1.92

1.23

1.27

1.32

1.38

1.44

1.54

1.72

1.93

2.06

1.35

1.40

1.48

1.54

1.64

1.70

1.88

2.11

2.27

1.46

1.50

1.59

1.71

1.81

1.89

2.04

2.28

2.43

1/0

2/0

3/0

4/0

250

350

500

750

1000

19 wire

19 wire

19 wire

19 wire

37 wire

37 wire

37 wire

61 wire

61 wire

6

7

9

11

13

11

16

15

20

14

14

14

14

14

12

12

10

10

eliminating unequal electrical stress.

loss, chemical resistance.

Specifications:

Aluminum conductors are also available strand-filled.

ICEA S-94-649; AEIC CS 8

Short Circuit - 250 CO

Dimensions and weights are nominal, and subject to standard industry tolerances.

Normal Operation - 90 C; Emergency Overload - 130 CO O

Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.

1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,

Maximum Conductor

Temperatures:

Application:

Features:

2. Ethylene Propylene Rubber (EPR) insulation offers: excellent heat, moisture and corona resistance; electrical stability under stress; low dielectric

Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)

AWG or

MCMStranding Conductor Conductor

Size

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

2

1

1/0

2/0

3/0

4/0

250

350

500

750

1000

7 wire

19 wire

19 wire

19 wire

19 wire

19 wire

37 wire

37 wire

37 wire

61 wire

61 wire

6

7

9

11

14

11

13

12

17

25

33

14

14

14

14

14

12

12

10

10

10

10

0.29

0.33

0.37

0.42

0.47

0.53

0.57

0.68

0.81

0.99

1.14

0.69

0.73

0.77

0.82

0.87

0.93

0.99

1.09

1.22

1.41

1.57

0.75

0.80

0.84

0.88

0.93

0.99

1.05

1.19

1.33

1.52

1.71

0.88

0.93

0.97

1.01

1.10

1.15

1.19

1.36

1.49

1.72

1.92

0.98

1.03

1.07

1.11

1.20

1.25

129

1.46

1.59

1.89

2.03

204.9

258.4

325.8

410.9

518.1

653.3

771.9

1081

1544

2316

3088

79.3

92.6

119.2

146.3

185.9

228.0

282.1

398.0

543.5

801.5

1058

545

636

749

891

1056

1267

1487

2022

2712

3873

5028

608

700

814

969

1135

1348

1597

2164

2860

4063

5231

CONDUMEX VULCANEL CABLEPrimary URD 15 KV 100% Insulation Level175 Mils EPR Insulation

ConductorAWG or

MCM

Copper Neutral (Full) Diameter (Inches) Weight (Pounds)

Stranding Conductor ConductorSize

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

2

1

1/0

2/0

3/0

4/0

7 wire

19 wire

19 wire

19 wire

19 wire

19 wire

10

13

16

20

16

20

14

12

12

12

12

12

0.29

0.33

0.37

0.42

0.47

0.53

0.69

0.73

0.77

0.82

0.87

0.93

0.75

0.80

0.84

0.88

0.93

0.99

0.88

0.93

0.97

1.01

1.10

1.15

0.98

1.03

1.07

1.11

1.20

1.26

204.9

258.4

325.8

410.9

518.1

653.3

210.9

267.8

330.3

421.4

527.9

663.3

677

811

960

1116

1398

170

740

875

1025

1244

1477

1784

Copper Conductor, CompressedSoft-drawn, Bare

CONDUMEX VULCANEL CABLEPrimary URD 15 KV 133% Insulation Level220 Mils EPR Insulation

eliminating unequal electrical stress.

loss, chemical resistance.

Specifications:

Aluminum conductors are also available strand-filled.

ICEA S-94-649; AEIC CS 8

Short Circuit - 250 CO

Dimensions and weights are nominal, and subject to standard industry tolerances.

Normal Operation - 90 C; Emergency Overload - 130 CO O

Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.

1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,

Maximum Conductor

Temperatures:

Application:

Features:

2. Ethylene Propylene Rubber (EPR) insulation offers: excellent heat, moisture and corona resistance; electrical stability under stress; low dielectric

Copper Conductor, CompressedSoft-drawn, Bare

ConductorAWG or

MCM

Copper Neutral (Full) Diameter (Inches) Weight (Pounds)

Stranding Conductor ConductorSize

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

2

1

1/0

2/0

3/0

4/0

7 wire

19 wire

19 wire

19 wire

19 wire

19 wire

10

13

16

20

16

20

14

12

12

12

12

12

0.29

0.33

0.37

0.42

0.47

0.53

0.78

0.83

0.87

0.91

0.96

1.02

0.84

0.89

0.93

0.96

1.03

1.12

0.97

1.04

1.08

1.10

1.19

1.29

1.075

1.141

1.181

1.207

1.291

1.389

204.9

258.4

325.8

410.9

518.1

653.3

210.9

267.8

330.3

421.4

527.9

663.3

756

881

1036

1242

1476

1829

825

951

1109

1329

1565

1922

Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)

AWG or

MCMStranding Conductor Conductor

Size

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

2

1

1/0

2/0

3/0

4/0

250

350

500

750

1000

7 wire

19 wire

19 wire

19 wire

19 wire

19 wire

37 wire

37 wire

37 wire

61 wire

61 wire

6

7

9

11

14

11

13

12

17

25

33

14

14

14

14

14

12

12

10

10

10

10

0.29

0.33

0.37

0.42

0.47

0.53

0.57

0.68

0.81

0.99

1.14

0.78

0.83

0.87

0.91

0.96

1.02

1.08

1.18

1.31

1.51

1.66

0.84

0.89

0.93

0.96

1.02

1.08

1.18

1.31

1.51

1.66

0.84

0.89

0.93

0.98

1.03

1.12

1.18

1.29

1.42

1.61

1.81

0.97

1.04

1.08

1.10

1.19

1.31

1.41

1.49

1.62

1.81

2.01

1.075

204.9

258.4

325.8

410.9

518.1

653.3

771.9

1081

1544

2316

3088

79.3

92.6

119.2

146.3

185.9

228.0

282.1

398.0

543.5

801.5

1058

624

706

825

967

1134

1393

1616

2130

2825

4058

5171

693

776

898

1054

1223

1486

1730

2280

2985

4263

5386

eliminating unequal electrical stress.

loss, chemical resistance.

Specifications:

Aluminum conductors are also available strand-filled.

ICEA S-94-649; AEIC CS 8

Short Circuit - 250 CO

Dimensions and weights are nominal, and subject to standard industry tolerances.

Normal Operation - 90 C; Emergency Overload - 130 CO O

Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.

1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,

Maximum Conductor

Temperatures:

Application:

Features:

2. Ethylene Propylene Rubber (EPR) insulation offers: excellent heat, moisture and corona resistance; electrical stability under stress; low dielectric

Copper Conductor, Compressed

CONDUMEX VULCANEL CABLEPrimary URD 25 KV 100% Insulation Level260 Mils EPR Insulation

Soft-drawn, Bare

Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)

AWG or

MCMStranding Conductor Conductor

Size

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

0.33

0.37

0.42

0.47

0.53

0.57

0.68

0.81

0.99

1.14

0.91

0.95

0.99

1.04

1.10

1.16

1.26

1.40

1.59

1.74

0.97

1.01

1.06

1.15

1.21

1.26

1.40

1.50

1.73

1.89

1.10

1.14

1.19

1.31

1.39

1.49

1.57

1.70

1.94

2.09

1.20

1.24

1.29

1.41

1.47

1.59

1.74

1.87

2.10

2.26

258.4

325.8

410.9

518.1

653.3

771.9

1081

1544

2316

3088

92.6

119.2

146.3

185.9

228.0

282.1

398.0

543.5

801.5

1058

776

896

1045

1246

1491

1724

2239

2951

4208

5331

859

996

1148

1353

1634

1896

2423

3185

4453

5331

1

1/0

2/0

3/0

4/0

250

350

500

750

1000

19 wire

19 wire

19 wire

19 wire

19 wire

37 wire

37 wire

37 wire

61 wire

61 wire

7

9

11

14

11

13

12

17

25

33

14

14

14

14

12

12

10

10

10

10

ConductorAWG or

MCM

Copper Neutral (Full) Diameter (Inches) Weight (Pounds)

Stranding Conductor ConductorSize

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

1

1/0

2/0

3/0

4/0

19 wire

19 wire

19 wire

19 wire

19 wire

13

16

20

25

32

12

12

12

12

12

0.33

0.37

0.42

0.47

0.53

0.91

0.95

0.99

1.04

1.10

0.97

1.01

1.06

1.15

1.21

1.10

1.16

1.19

1.31

1.37

1.20

1.26

1.29

1.41

1.47

258.4

325.8

410.9

518.1

653.3

267.8

330.3

421.4

527.9

663.3

951

1107

1320

1588

1927

1032

1190

1420

1691

2034

Copper Conductor, Compressed

CONDUMEX VULCANEL CABLEPrimary URD 35 KV 100% Insulation Level345 Mils EPR Insulation

Soft-drawn, Bare

eliminating unequal electrical stress.

loss, chemical resistance.

Specifications:

Aluminum conductors are also available strand-filled.

ICEA S-94-649; AEIC CS 8

Short Circuit - 250 CO

Dimensions and weights are nominal, and subject to standard industry tolerances.

Normal Operation - 90 C; Emergency Overload - 130 CO O

Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.

1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,

Maximum Conductor

Temperatures:

Application:

Features:

2. Ethylene Propylene Rubber (EPR) insulation offers: excellent heat, moisture and corona resistance; electrical stability under stress; low dielectric

ConductorAWG or

MCM

Copper Neutral (Full) Diameter (Inches) Weight (Pounds)

Stranding Conductor ConductorSize

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

1/0

2/0

3/0

4/0

19 wire

19 wire

19 wire

19 wire

16

20

25

32

12

12

12

12

0.37

0.42

0.47

0.53

1.12

1.17

1.22

1.28

1.23

1.27

1.32

1.38

1.35

1.40

1.48

1.54

1.46

1.50

1.59

1.71

325.8

410.9

518.1

653.3

330.3

421.4

517.9

663.3

1313

1539

1786

2127

1413

1658

1906

2252

Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)

AWG or

MCMStranding Conductor Conductor

Size

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

325.8

410.9

518.1

653.3

771.9

1081

1544

2316

3088

119.2

146.3

185.9

228.0

282.1

398.0

543.5

801.5

1058

1102

1264

1444

1691

1939

2469

3273

4504

5647

1221

1384

1569

1874

2133

2679

3533

4776

-

0.37

0.42

0.47

0.53

0.57

0.68

0.81

0.99

1.14

1.12

1.17

1.22

1.28

1.33

1.44

1.57

1.76

1.92

1.23

1.27

1.32

1.38

1.44

1.54

1.72

1.93

2.06

1.35

1.40

1.48

1.54

1.64

1.70

1.88

2.11

2.27

1.46

1.50

1.59

1.71

1.81

1.89

2.04

2.28

2.43

1/0

2/0

3/0

4/0

250

350

500

750

1000

19 wire

19 wire

19 wire

19 wire

37 wire

37 wire

37 wire

61 wire

61 wire

9

11

14

11

13

12

17

25

33

14

14

14

12

12

10

10

10

10

Aluminum Conductor, Compressed

CONDUMEX VULCANEL CABLEPrimary URD 15 KV 100% Insulation Level175 Mils TR-XLP Insulation

Hard-drawn, EC-1350 Alloy

eliminating unequal electrical stress.

stability under stress; low dielectric loss, chemical resistance.

Specifications:

Aluminum conductors are also available strand-filled.

ICEA S-94-649; AEIC CS 8

Short Circuit - 250 CO

Dimensions and weights are nominal, and subject to standard industry tolerances.

Normal Operation - 90 C; Emergency Overload - 130 CO O

Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.

1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,

Maximum Conductor

Temperatures:

Application:

Features:

2. Tree-retardant Cross-Link Polyethylene Ethylene Propylene Rubber (TR-XLP) insulation offers: excellent heat, moisture and corona resistance; electrical

ConductorAWG or

MCM

Copper Neutral (Full) Diameter (Inches) Weight (Pounds)

Stranding Conductor ConductorSize

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

2

1

1/0

2/0

3/0

4/0

7 wire

19 wire

19 wire

19 wire

19 wire

19 wire

10

13

16

20

16

20

14

14

14

12

12

12

0.29

0.33

0.37

0.42

0.47

0.53

0.69

0.73

0.77

0.82

0.87

0.93

0.75

0.80

0.84

0.88

0.93

0.99

0.88

0.93

0.97

1.01

1.10

1.15

0.98

1.03

1.07

1.11

1.20

1.26

62.2

79.0

98.8

124.6

157.5

198.2

132.1

172.0

212.0

273.0

338.0

425.0

379

452

528

627

752

904

496

571

650

750

902

1055

Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)

AWG or

MCMStranding Conductor Conductor

Size

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

2

1

1/0

2/0

3/0

4/0

250

350

500

750

1000

7 wire

19 wire

19 wire

19 wire

19 wire

19 wire

37 wire

37 wire

37 wire

61 wire

61 wire

6

6

6

7

9

11

13

11

16

15

20

14

14

14

14

14

14

14

12

12

10

10

0.29

0.33

0.37

0.42

0.47

0.53

0.57

0.68

0.81

0.99

1.14

0.69

0.73

0.77

0.82

0.87

0.93

0.99

1.09

1.22

1.41

1.57

0.75

0.80

0.84

0.88

0.93

0.99

1.05

1.19

1.33

1.52

1.71

0.88

0.93

0.97

1.01

1.10

1.13

1.17

1.36

1.49

1.72

1.92

0.98

1.03

1.07

1.11

1.20

1.23

1.27

1.46

1.59

1.89

2.03

62.2

79.0

98.8

124.6

157.5

198.2

234.5

327.9

468.3

702.5

936.8

79.3

79.4

79.5

93.1

120.2

152.4

181.0

240.0

350.0

501.7

705.6

326

359

396

447

534

631

728

966

1230

1716

2246

445

480

521

573

689

788

939

1241

1521

2091

2558

Aluminum Conductor, Compressed

CONDUMEX VULCANEL CABLEPrimary URD 15 KV 133% Insulation Level220 Mils TR-XLP Insulation

Hard-drawn, EC-1350 Alloy

ConductorAWG or

MCM

Copper Neutral (Full) Diameter (Inches) Weight (Pounds)

Stranding Conductor ConductorSize

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

2

1

1/0

2/0

3/0

4/0

7 wire

19 wire

19 wire

19 wire

19 wire

19 wire

10

13

16

20

16

20

14

14

14

12

12

12

0.29

0.33

0.37

0.42

0.47

0.53

0.78

0.83

0.87

0.91

0.96

1.02

0.84

0.89

0.93

0.98

1.03

1.12

0.97

1.02

1.06

1.10

1.19

1.29

1.075

1.121

1.161

1.207

1.291

1.386

62.2

79.0

98.8

124.6

157.5

198.2

132.1

172.0

212.0

273.0

338.0

425.0

426

495

570

680

801

950

560

631

707

822

966

1123

Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)

AWG or

MCMStranding Conductor Conductor

Size

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

2

1

1/0

2/0

3/0

4/0

250

350

500

750

1000

7 wire

19 wire

19 wire

19 wire

19 wire

19 wire

37 wire

37 wire

37 wire

61 wire

61 wire

6

6

6

7

9

11

13

11

16

15

20

14

14

14

14

14

14

14

12

12

10

10

0.29

0.33

0.37

0.42

0.47

0.53

0.57

0.68

0.81

0.99

1.14

0.78

0.83

0.87

0.91

0.96

1.02

1.08

1.18

1.31

1.51

1.66

0.84

0.89

0.93

0.98

1.03

1.12

1.18

1.29

1.42

1.61

1.81

0.97

1.02

1.06

1.10

1.19

1.27

1.37

1.45

1.58

1.81

2.01

1.075

1.121

1.161

1.207

1.291

1.369

1.469

1.552

1.746

1.980

2.175

62.2

79.0

98.8

124.6

157.5

198.2

234.5

327.9

468.3

702.5

936.8

79.3

79.4

79.5

93.1

120.2

152.4

181.0

240.0

350.0

501.7

705.6

373

402

438

583

622

677

795

1002

1298

1796

2325

509

541

579

752

767

855

1027

1282

1616

2266

2772

eliminating unequal electrical stress.

stability under stress; low dielectric loss, chemical resistance.

Specifications:

Aluminum conductors are also available strand-filled.

ICEA S-94-649; AEIC CS 8

Short Circuit - 250 CO

Dimensions and weights are nominal, and subject to standard industry tolerances.

Normal Operation - 90 C; Emergency Overload - 130 CO O

Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.

1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,

Maximum Conductor

Temperatures:

Application:

Features:

2. Tree-retardant Cross-Link Polyethylene Ethylene Propylene Rubber (TR-XLP) insulation offers: excellent heat, moisture and corona resistance; electrical

Aluminum Conductor, Compressed

CONDUMEX VULCANEL CABLEPrimary URD 25 KV 100% Insulation Level260 Mils EPR Insulation

Hard-drawn, EC-1350 Alloy

Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)

AWG or

MCMStranding Conductor Conductor

Size

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

0.33

0.37

0.42

0.47

0.53

0.57

0.68

0.81

0.99

1.14

0.91

0.95

0.99

1.04

1.10

1.16

1.26

1.40

1.59

1.74

0.97

1.01

1.06

1.15

1.21

1.26

1.40

1.50

1.73

1.89

1.10

1.14

1.19

1.31

1.37

1.47

1.53

1.66

1.94

2.09

1.20

1.24

1.29

1.41

1.47

1.57

1.70

1.83

2.10

2.26

79.0

98.8

124.6

157.5

198.2

234.5

327.9

468.3

702.5

936.8

79.4

79.5

93.1

120.2

152.4

181.0

240.0

350.0

501.7

705.6

466

508

560

683

799

994

1090

1380

1933

2422

615

656

715

865

988

1247

1377

1690

2321

2833

1

1/0

2/0

3/0

4/0

250

350

500

750

1000

19 wire

19 wire

19 wire

19 wire

19 wire

37 wire

37 wire

37 wire

61 wire

61 wire

6

6

7

9

11

13

11

16

15

20

14

14

14

14

14

14

12

12

10

10

ConductorAWG or

MCM

Copper Neutral (Full) Diameter (Inches) Weight (Pounds)

Stranding Conductor ConductorSize

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

1

1/0

2/0

3/0

4/0

19 wire

19 wire

19 wire

19 wire

19 wire

13

16

13

16

20

14

14

12

12

12

0.33

0.37

0.42

0.47

0.53

0.91

0.95

0.99

1.04

1.10

0.97

1.01

1.06

1.15

1.21

1.10

1.14

1.19

1.31

1.37

1.20

1.24

1.29

1.41

1.47

79.0

96.8

124.6

157.5

198.2

172.0

212.0

273.0

338.0

425.0

558

639

740

901

1070

704

787

890

1076

1253

eliminating unequal electrical stress.

stability under stress; low dielectric loss, chemical resistance.

Specifications:

Aluminum conductors are also available strand-filled.

ICEA S-94-649; AEIC CS 8

Short Circuit - 250 CO

Dimensions and weights are nominal, and subject to standard industry tolerances.

Normal Operation - 90 C; Emergency Overload - 130 CO O

Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.

1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,

Maximum Conductor

Temperatures:

Application:

Features:

2. Tree-retardant Cross-Link Polyethylene Ethylene Propylene Rubber (TR-XLP) insulation offers: excellent heat, moisture and corona resistance; electrical

Aluminum Conductor, Compressed

CONDUMEX VULCANEL CABLEPrimary URD 35 KV 100% Insulation Level345 Mils TR-XLP Insulation

Hard-drawn, EC-1350 Alloy

ConductorAWG or

MCM

Copper Neutral (Full) Diameter (Inches) Weight (Pounds)

Stranding Conductor ConductorSize

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

1/0

2/0

3/0

4/0

19 wire

19 wire

19 wire

19 wire

16

13

16

20

14

12

12

12

0.37

0.42

0.47

0.53

1.12

1.17

1.22

1.26

1.23

1.27

1.32

1.38

1.35

1.40

1.48

1.54

1.46

1.50

1.59

1.71

98.8

124.6

157.5

198.2

212.0

273.0

338.0

425.0

775

902

1031

1196

966

1123

1257

1453

Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)

AWG or

MCMStranding Conductor Conductor

Size

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

98.8

124.6

157.5

198.2

234.5

327.9

468.3

702.5

936.8

79.5

93.1

120.2

152.4

181.0

240.0

350.0

501.7

705.6

644

751

817

824

1031

1247

1636

2157

2763

839

982

1051

1190

1338

1615

2050

2669

3184

0.37

0.42

0.47

0.53

0.57

0.68

0.81

0.99

1.14

1.12

1.17

1.22

1.28

1.33

1.44

1.57

1.76

1.92

1.23

1.27

1.32

1.38

1.44

1.54

1.72

1.93

2.06

1.35

1.40

1.48

1.54

1.64

1.70

1.88

2.11

2.27

1.46

1.50

1.59

1.71

1.81

1.89

2.04

2.28

2.43

1/0

2/0

3/0

4/0

250

350

500

750

1000

19 wire

19 wire

19 wire

19 wire

37 wire

37 wire

37 wire

61 wire

61 wire

6

7

9

11

13

11

16

15

20

14

14

14

14

14

12

12

10

10

eliminating unequal electrical stress.

stability under stress; low dielectric loss, chemical resistance.

Specifications:

Aluminum conductors are also available strand-filled.

ICEA S-94-649; AEIC CS 8

Short Circuit - 250 CO

Dimensions and weights are nominal, and subject to standard industry tolerances.

Normal Operation - 90 C; Emergency Overload - 130 CO O

Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.

1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,

Maximum Conductor

Temperatures:

Application:

Features:

2. Tree-retardant Cross-Link Polyethylene Ethylene Propylene Rubber (TR-XLP) insulation offers: excellent heat, moisture and corona resistance; electrical

CONDUMEX VULCANEL CABLEPrimary URD 15 KV 100% Insulation Level175 Mils TR-XLP Insulation

Copper Conductor, CompressedSoft-drawn, Bare

ConductorAWG or

MCM

Copper Neutral (Full) Diameter (Inches) Weight (Pounds)

Stranding Conductor ConductorSize

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

2

1

1/0

2/0

3/0

4/0

7 wire

19 wire

19 wire

19 wire

19 wire

19 wire

10

13

16

20

16

20

14

12

12

12

12

12

0.29

0.33

0.37

0.42

0.47

0.53

0.69

0.73

0.77

0.82

0.87

0.93

0.75

0.80

0.84

0.88

0.93

0.99

0.88

0.93

0.97

1.01

1.10

1.15

0.98

1.03

1.07

1.11

1.20

1.26

204.9

258.4

325.8

410.9

518.1

653.3

210.9

267.8

330.3

421.4

527.9

663.3

514

654

937

1124

1358

1662

580

715

1011

1192

1430

1730

eliminating unequal electrical stress.

stability under stress; low dielectric loss, chemical resistance.

Specifications:

Copper conductors are also available strand-filled.

ICEA S-94-649; AEIC CS 8

Short Circuit - 250 CO

Dimensions and weights are nominal, and subject to standard industry tolerances.

Normal Operation - 90 C; Emergency Overload - 130 CO O

Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.

1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,

Maximum Conductor

Temperatures:

Application:

Features:

2. Tree-retardant Cross-Link Polyethylene Ethylene Propylene Rubber (TR-XLP) insulation offers: excellent heat, moisture and corona resistance; electrical

Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)

AWG or

MCMStranding Conductor Conductor

Size

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

2

1

1/0

2/0

3/0

4/0

250

350

500

750

1000

7 wire

19 wire

19 wire

19 wire

19 wire

19 wire

37 wire

37 wire

37 wire

61 wire

61 wire

6

7

9

11

14

11

13

12

17

25

33

14

14

14

14

14

12

12

10

10

10

10

0.29

0.33

0.37

0.42

0.47

0.53

0.57

0.68

0.81

0.99

1.14

0.69

0.73

0.77

0.82

0.87

0.93

0.99

1.09

1.22

1.41

1.57

0.75

0.80

0.84

0.88

0.93

0.99

1.05

1.19

1.33

1.52

1.71

0.88

0.93

0.97

1.01

1.10

1.15

1.19

1.36

1.49

1.72

1.92

0.98

1.03

1.07

1.11

1.20

1.25

129

1.46

1.59

1.89

2.03

204.9

258.4

325.8

410.9

518.1

653.3

771.9

1081

1544

2316

3088

79.3

92.6

119.2

146.3

185.9

228.0

282.1

398.0

543.5

801.5

1058

383

479

710

846

1016

1228

1433

1915

2683

3855

5007

451

542

788

917

1090

1311

1555

2070

2847

4031

5193

Copper Conductor, Compressed

CONDUMEX VULCANEL CABLEPrimary URD 15 KV 133% Insulation Level220 Mils TR-XLP Insulation

Soft-drawn, Bare

ConductorAWG or

MCM

Copper Neutral (Full) Diameter (Inches) Weight (Pounds)

Stranding Conductor ConductorSize

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

2

1

1/0

2/0

3/0

4/0

7 wire

19 wire

19 wire

19 wire

19 wire

19 wire

10

13

16

20

16

20

14

12

12

12

12

12

0.29

0.33

0.37

0.42

0.47

0.53

0.78

0.83

0.87

0.91

0.96

1.02

0.84

0.89

0.93

0.96

1.03

1.12

0.97

1.04

1.08

1.10

1.19

1.29

1.075

1.141

1.181

1.207

1.291

1.389

204.9

258.4

325.8

410.9

518.1

653.3

210.9

267.8

330.3

421.4

527.9

663.3

564

701

988

1177

1405

1754

633

772

1069

1257

1486

1836

Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)

AWG or

MCMStranding Conductor Conductor

Size

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

2

1

1/0

2/0

3/0

4/0

250

350

500

750

1000

7 wire

19 wire

19 wire

19 wire

19 wire

19 wire

37 wire

37 wire

37 wire

61 wire

61 wire

6

7

9

11

14

11

13

12

17

25

33

14

14

14

14

14

12

12

10

10

10

10

0.29

0.33

0.37

0.42

0.47

0.53

0.57

0.68

0.81

0.99

1.14

0.78

0.83

0.87

0.91

0.96

1.02

1.08

1.18

1.31

1.51

1.66

0.84

0.89

0.93

0.96

1.02

1.08

1.18

1.31

1.51

1.66

0.84

0.89

0.93

0.98

1.03

1.12

1.18

1.29

1.42

1.61

1.81

0.97

1.04

1.08

1.10

1.19

1.31

1.41

1.49

1.62

1.81

2.01

1.075

204.9

258.4

325.8

410.9

518.1

653.3

771.9

1081

1544

2316

3088

79.3

92.6

119.2

146.3

185.9

228.0

282.1

398.0

543.5

801.5

1058

433

526

778

903

1065

1320

1564

2009

2781

3998

5112

504

600

863

986

1150

1407

1700

2174

2959

4196

5310

eliminating unequal electrical stress.

stability under stress; low dielectric loss, chemical resistance.

Specifications:

Copper conductors are also available strand-filled.

ICEA S-94-649; AEIC CS 8

Short Circuit - 250 CO

Dimensions and weights are nominal, and subject to standard industry tolerances.

Normal Operation - 90 C; Emergency Overload - 130 CO O

Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.

1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,

Maximum Conductor

Temperatures:

Application:

Features:

2. Tree-retardant Cross-Link Polyethylene Ethylene Propylene Rubber (TR-XLP) insulation offers: excellent heat, moisture and corona resistance; electrical

Copper Conductor, Compressed

CONDUMEX VULCANEL CABLEPrimary URD 25 KV 100% Insulation Level260 Mils TR-XLP Insulation

Soft-drawn, Bare

Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)

AWG or

MCMStranding Conductor Conductor

Size

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

0.33

0.37

0.42

0.47

0.53

0.57

0.68

0.81

0.99

1.14

0.91

0.95

0.99

1.04

1.10

1.16

1.26

1.40

1.59

1.74

0.97

1.01

1.06

1.15

1.21

1.26

1.40

1.50

1.73

1.89

1.10

1.14

1.19

1.31

1.39

1.49

1.57

1.70

1.94

2.09

1.20

1.24

1.29

1.41

1.47

1.59

1.74

1.87

2.10

2.26

258.4

325.8

410.9

518.1

653.3

771.9

1081

1544

2316

3088

92.6

119.2

146.3

185.9

228.0

282.1

398.0

543.5

801.5

1058

659

775

900

1180

1330

1633

2002

2650

3847

4926

808

923

1055

1292

1519

1886

2289

2960

4235

5337

1

1/0

2/0

3/0

4/0

250

350

500

750

1000

19 wire

19 wire

19 wire

19 wire

19 wire

37 wire

37 wire

37 wire

61 wire

61 wire

7

9

11

14

11

13

12

17

25

33

14

14

14

14

12

12

10

10

10

10

ConductorAWG or

MCM

Copper Neutral (Full) Diameter (Inches) Weight (Pounds)

Stranding Conductor ConductorSize

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

1

1/0

2/0

3/0

4/0

19 wire

19 wire

19 wire

19 wire

19 wire

13

16

20

25

32

12

12

12

12

12

0.33

0.37

0.42

0.47

0.53

0.91

0.95

0.99

1.04

1.10

0.97

1.01

1.06

1.15

1.21

1.10

1.16

1.19

1.31

1.37

1.20

1.26

1.29

1.41

1.47

258.4

325.8

410.9

518.1

653.3

267.8

330.3

421.4

527.9

663.3

834

987

1175

1452

1764

980

1135

1325

1627

1947

eliminating unequal electrical stress.

stability under stress; low dielectric loss, chemical resistance.

Specifications:

Copper conductors are also available strand-filled.

ICEA S-94-649; AEIC CS 8

Short Circuit - 250 CO

Dimensions and weights are nominal, and subject to standard industry tolerances.

Normal Operation - 90 C; Emergency Overload - 130 CO O

Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.

1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,

Maximum Conductor

Temperatures:

Application:

Features:

2. Tree-retardant Cross-Link Polyethylene Ethylene Propylene Rubber (TR-XLP) insulation offers: excellent heat, moisture and corona resistance; electrical

Copper Conductor, Compressed

CONDUMEX VULCANEL CABLEPrimary URD 35 KV 100% Insulation Level345 Mils TR-XLP Insulation

Soft-drawn, Bare

ConductorAWG or

MCM

Copper Neutral (Full) Diameter (Inches) Weight (Pounds)

Stranding Conductor ConductorSize

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

1/0

2/0

3/0

4/0

19 wire

19 wire

19 wire

19 wire

16

20

25

32

12

12

12

12

0.37

0.42

0.47

0.53

1.12

1.17

1.22

1.28

1.23

1.27

1.32

1.38

1.35

1.40

1.48

1.54

1.46

1.50

1.59

1.71

325.8

410.9

518.1

653.3

330.3

421.4

517.9

663.3

834

987

1175

1452

1764

980

1135

1325

Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)

AWG or

MCMStranding Conductor Conductor

Size

AWG (Solid)

Number of

Wires

Over

Insulation

Over Neutral

Wires

Over Insul.

Shield

Over

Encaps. Jkt.

Concentric

Neutral

Total

No Jacket

Total With

Jacket

325.8

410.9

518.1

653.3

771.9

1081

1544

2316

3088

119.2

146.3

185.9

228.0

282.1

398.0

543.5

801.5

1058

659

775

900

1110

1330

1633

2002

2650

3847

4926

808

923

1055

1292

1519

1886

2289

2960

0.37

0.42

0.47

0.53

0.57

0.68

0.81

0.99

1.14

1.12

1.17

1.22

1.28

1.33

1.44

1.57

1.76

1.92

1.23

1.27

1.32

1.38

1.44

1.54

1.72

1.93

2.06

1.35

1.40

1.48

1.54

1.64

1.70

1.88

2.11

2.27

1.46

1.50

1.59

1.71

1.81

1.89

2.04

2.28

2.43

1/0

2/0

3/0

4/0

250

350

500

750

1000

19 wire

19 wire

19 wire

19 wire

37 wire

37 wire

37 wire

61 wire

61 wire

9

11

14

11

13

12

17

25

33

14

14

14

12

12

10

10

10

10

eliminating unequal electrical stress.

stability under stress; low dielectric loss, chemical resistance.

Specifications:

Copper conductors are also available strand-filled.

ICEA S-94-649; AEIC CS 8

Short Circuit - 250 CO

Dimensions and weights are nominal, and subject to standard industry tolerances.

Normal Operation - 90 C; Emergency Overload - 130 CO O

Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.

1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,

Maximum Conductor

Temperatures:

Application:

Features:

2. Tree-retardant Cross-Link Polyethylene Ethylene Propylene Rubber (TR-XLP) insulation offers: excellent heat, moisture and corona resistance; electrical