ALTIVAR 66 Drive - Steven Engineering

13
24-9 3/00 © 2000 Square D All Rights Reserved 24 AC DRIVES ALTIVAR 66 AC Drives and Options Full-featured AC Drive–208/230 V and 460 V ratings The ALTIVAR 66 is a sensorless flux vector AC drive using the latest in motor control technology. Every unit has the following standard features: Advanced LCD graphic keypad with pull down menu programming and bar graph parameter display in six languages. Built-in I/O map, diagnostic routines and fault history assist in set-up and troubleshooting. UL Listed electronic motor overload protection. In constant torque mode for industrial and OEM applications, each unit provides: Autotuning to achieve exceptional torque performance with a standard motor without encoder feedback. Up to 8 preset speeds. External brake sequencing. Multi-motor control In variable torque mode for fan and pump applications, each unit provides: NOLD adaptive motor flux control for low noise operation and improved system efficiency. Auto restart: up to 5 times, up to 600 seconds apart. Skip frequency avoidance: up to 3 programmable bands, 2 Hz or 5 Hz. PI regulator control. Options and accessories (on page 24-10) to customize the ATV66: Extended I/O options including 120 Vac control Dynamic braking kits for reduced cycle times and increased available braking torque. Serial link monitoring and control over Modbus or Modbus Plus Networks Test and commissioning PC software for off-line programming and drive set-up archiving. q Motor rated Hp at listed line voltage (see motor nameplate). c Motor FLA (see motor nameplate). l For applications requiring dynamic braking, replace suffix “U” with “BU”. Example: for 100 Hp constant torque drive with internal dynamic braking switch, order catalog number ATV66C10N4BU. Note: For higher HP pricing, refer to Enclosed Drives ALTIVAR 66 on page 24-12. Selection and Pricing Input Line Voltage 50/60 Hz ± 5% Three Phase Motor Powerq ATV66 Continuous Output Current c Catalog Number Price Constant Torque Variable Torque Variable Torque Low Noise Constant Torque Variable Torque Variable Torque Low Noise V Hp Hp Hp A A A ATV66... 208 – 10% to 230 + 15% Three Phase 1 to 3 1 to 3 1 to 3 10.6 10.6 10.6 ATV66U41M2U $ 1667. 5 5 to 7.5 5 16.7 24.2 16.7 ATV66U72M2U 1931. 7.5 10 7.5 24.2 30.8 24.2 ATV66U90M2U 2606. 10 15 10 30.8 46.2 30.8 ATV66D12M2U 3651. 15 ... 15 46.2 ... 46.2 ATV66D16M2U 4414. 20 20 to 25 20 59.4 74.8 59.4 ATV66D23M2S264U 5318. 25 to 30 30 to 40 25 to 30 88.0 114.4 88.0 ATV66D33M2U 7030. 40 50 40 114.4 143.0 114.4 ATV66D46M2U 9069. 460 ± 15% Three Phase 1 to 3 1 to 3 1 to 3 4.8 4.8 4.8 ATV66U41N4U 1878. ... 5 ... ... 7.6 ... ATV66U54N4U 2055. 5 7.5 5 7.6 11.0 7.6 ATV66U72N4U 2242. 7.5 10 7.5 11.0 14.0 11.0 ATV66U90N4U 2806. 10 15 10 14.0 21.0 14.0 ATV66D12N4U 3604. 15 20 15 21.0 27.0 21.0 ATV66D16N4U 4519. 20 25 20 27.0 34.0 27.0 ATV66D23N4U 5611. 25 to 30 30 to 40 25 to 30 40.0 52.0 40.0 ATV66D33N4U 7982. 40 50 40 52.0 65.0 52.0 ATV66D46N4U 10225. 50 60 50 65.0 77.0 65.0 ATV66D54N4U 12408. 60 75 60 77.0 96.0 77.0 ATV66D64N4U 14427. 75 100 75 96.0 124.0 96.0 ATV66D79N4U 17339. 100 125 ... 124.0 156.0 ... ATV66C10N4Ul 19564. 100 125 ... 124.0 156.0 ... ATV66C10N4BU 20543. 125 150 ... 156.0 180.0 ... ATV66C13N4Ul 23005. 125 150 ... 156.0 180.0 ... ATV66C13N4BU 24156. 150 200 ... 180.0 240.0 ... ATV66C15N4Ul 26011. 150 200 ... 180.0 240.0 ... ATV66C15N4BU 27312. 200 ... ... 240.0 ... ... ATV66C19N4Ul 31566. 200 ... ... 240.0 ... ... ATV66C19N4BU 33144. Open Drives ALTIVAR ® 66 AC Drives 208/230 V and 460 V Ratings ALTIVAR is a Registered Trademark of Square D Company or related companies. CP4C Discount Schedule Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com

Transcript of ALTIVAR 66 Drive - Steven Engineering

Page 1: ALTIVAR 66 Drive - Steven Engineering

Courtesy of Steve

Open DrivesALTIVAR® 66 AC Drives

208/230 V and 460 V Ratings

24A

C D

RIV

ES

ALTIVAR 66 AC Drives and Options

Full-featured AC Drive–208/230 V and 460 V ratings

The ALTIVAR 66 is a sensorless flux vector AC drive using the latest in motor control technology. Every unit has thefollowing standard features:

• Advanced LCD graphic keypad with pull down menu programming and bar graph parameter display in sixlanguages.

• Built-in I/O map, diagnostic routines and fault history assist in set-up and troubleshooting.

• UL Listed electronic motor overload protection.

In constant torque mode for industrial and OEM applications, each unit provides:

• Autotuning to achieve exceptional torque performance with a standard motor without encoder feedback.

• Up to 8 preset speeds.

• External brake sequencing.

• Multi-motor control

In variable torque mode for fan and pump applications, each unit provides:

• NOLD adaptive motor flux control for low noise operation and improved system efficiency.

• Auto restart: up to 5 times, up to 600 seconds apart.

• Skip frequency avoidance: up to 3 programmable bands, 2 Hz or 5 Hz.

• PI regulator control.

Options and accessories (on page 24-10) to customize the ATV66:

• Extended I/O options including 120 Vac control

• Dynamic braking kits for reduced cycle times and increased available braking torque.

• Serial link monitoring and control over Modbus or Modbus Plus Networks

• Test and commissioning PC software for off-line programming and drive set-up archiving.

q Motor rated Hp at listed line voltage (see motor nameplate).c Motor FLA (see motor nameplate).l For applications requiring dynamic braking, replace suffix “U” with “BU”. Example: for 100 Hp constant torque drive with internal dynamic braking switch, order

catalog number ATV66C10N4BU.

Note: For higher HP pricing, refer to Enclosed Drives ALTIVAR 66 on page 24-12.

Selection and Pricing

Input LineVoltage

50/60 Hz ± 5%

Three Phase Motor Power q ATV66 Continuous Output Current cCatalogNumber PriceConstant

TorqueVariableTorque

Variable TorqueLow Noise

ConstantTorque

VariableTorque

Variable TorqueLow Noise

V Hp Hp Hp A A A ATV66...

208 – 10%to

230 + 15%Three Phase

1 to 3 1 to 3 1 to 3 10.6 10.6 10.6 ATV66U41M2U $ 1667.5 5 to 7.5 5 16.7 24.2 16.7 ATV66U72M2U 1931.

7.5 10 7.5 24.2 30.8 24.2 ATV66U90M2U 2606.10 15 10 30.8 46.2 30.8 ATV66D12M2U 3651.

15 . . . 15 46.2 . . . 46.2 ATV66D16M2U 4414.20 20 to 25 20 59.4 74.8 59.4 ATV66D23M2S264U 5318.

25 to 30 30 to 40 25 to 30 88.0 114.4 88.0 ATV66D33M2U 7030.40 50 40 114.4 143.0 114.4 ATV66D46M2U 9069.

460 ± 15%Three Phase

1 to 3 1 to 3 1 to 3 4.8 4.8 4.8 ATV66U41N4U 1878.. . . 5 . . . . . . 7.6 . . . ATV66U54N4U 2055.5 7.5 5 7.6 11.0 7.6 ATV66U72N4U 2242.

7.5 10 7.5 11.0 14.0 11.0 ATV66U90N4U 2806.10 15 10 14.0 21.0 14.0 ATV66D12N4U 3604.

15 20 15 21.0 27.0 21.0 ATV66D16N4U 4519.20 25 20 27.0 34.0 27.0 ATV66D23N4U 5611.

25 to 30 30 to 40 25 to 30 40.0 52.0 40.0 ATV66D33N4U 7982.40 50 40 52.0 65.0 52.0 ATV66D46N4U 10225.50 60 50 65.0 77.0 65.0 ATV66D54N4U 12408.

60 75 60 77.0 96.0 77.0 ATV66D64N4U 14427.75 100 75 96.0 124.0 96.0 ATV66D79N4U 17339.

100 125 . . . 124.0 156.0 . . . ATV66C10N4Ul 19564.100 125 . . . 124.0 156.0 . . . ATV66C10N4BU 20543.125 150 . . . 156.0 180.0 . . . ATV66C13N4Ul 23005.

125 150 . . . 156.0 180.0 . . . ATV66C13N4BU 24156.150 200 . . . 180.0 240.0 . . . ATV66C15N4Ul 26011.150 200 . . . 180.0 240.0 . . . ATV66C15N4BU 27312.200 . . . . . . 240.0 . . . . . . ATV66C19N4Ul 31566.200 . . . . . . 240.0 . . . . . . ATV66C19N4BU 33144.

ALTIVAR is a Registered Trademark of Square D Company or related companies.

-9

ring.com

243/00

© 2000 Square DAll Rights Reserved

CP4C DiscountSchedule

n Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenenginee

Page 2: ALTIVAR 66 Drive - Steven Engineering

24A

C D

RIV

ES

C

Open DrivesALTIVAR® 66 AC DrivesOptions — Field Installed Kits

24

LoadLine

A1

B1

C1

A2

B2

C2

ourtes

q An I/O extension module or communication card carrier must also be ordered.c Designed for use with Telemecanique Type ZA2B 22 mm operators and 2- 1/2" surface mount meters. When used with compatible operators and meters and

the enclosed gasket, the control island maintains Type 12 / IP54 integrity of enclosure sidewall. Operators and meters are not included with the control island kit.l Mounting the dynamic braking resistor assemblies on the ATV66C23N4 to C31N4 AC Drives requires the use of the Dynamic Braking Resistor Mounting Plate

Kit VY1A66202.f Order quantity of 2. Two kits required on these units.j These RFI filters and ferrite cores are for use on equipment being designed for European power systems where CE compliance is required. Reference catalog

VVDED296034 for more information.

Selection and Pricing

Descript ion For Drives CatalogNumber Price

Extended I/O Options

24V I/O extension module ATV66 all ranges VW3A66201T $ 380.

115V I/O extension module ATV66 all ranges VW3A66202T 380.

Communication and Programming Options

PC test and commissioning software ATV66 all ranges VW3A66331 211.

PCMCIA memory card ATV66 all ranges VW3A66901T 528.

Communication card for Uni-Telway, Modbus RTU/JBUS, ModbusASCII networksq ATV66 all ranges VW3A66301U 554.

Communication card for Modbus Plus networkq ATV66 all ranges VW3A66305U 733.p

Communication card carrier ATV66 all ranges VW3A66205 317.

Enclosure Mount ing Options

Door mounting kit for keypad with 2 meter cable ATV66 all ranges VW3A66100 211.

Door mounting kit for keypad with 3 meter cable ATV66 all ranges VW3A66101 211.

2 meter keypad cable ATV66 all ranges VW3A66312 106.

3 meter keypad cable ATV66 all ranges VW3A66311 106.

Control island for eight operatorsc ATV66 all ranges VW3A66102 42.

Control island for six operators & one meterc ATV66 all ranges VW3A66103 42.

Control island for four operators & two metersc ATV66 all ranges VW3A66104 42.

Speed Potentiometer ATV66 all ranges ATVPOT25K 69.

Drive recess mounting kit - gasket onlyATV66U41N4–U72N4, U41M2 VW3A66801T 106.ATV66U90N4–D12N4, U72M2–U90M2 VW3A66802T 106.ATV66D16N4–D23N4, D12M2–D16M2 VW3A66803T 106.

Drive recess mounting kit - gasketand adaptor plate

ATV66U41N4–U72N4, U41M2 VW3A66806 211.ATV66U90N4–D12N4, U72M2–U90M2 VW3A66807 211.ATV66D16N4–D23N4, D12M2–D16M2 VW3A66808 211.

Dynamic Braking Options

Dynamic braking resistor withType 1 enclosure

ATV66U41N4–U72N4 VW3A66711 422.ATV66U90N4–D12N4 VW3A66712 633.ATV66D16N4–D23N4 VW3A66713 950.ATV66D33N4–D46N4 VW3A66714 1266.ATV66D54N4 VW3A66715 1846.ATV66D64N4–D79N4 VW3A66716 2321.ATV66C10N4–C19N4 VW3A66717 2743.ATV66C23N4l VW3A66718f 2743.ATV66C28N4–C31N4l VW3A66717f 2743.

Dynamic braking resistor mounting plate ATV66C23N4–C31N4l VY1A66202 380.

Miscellaneous Options

Metal conduit entry plate for wall mounted drives ATV66U41N4–D23N4, U41M2–D16M2 VY1A66201 53.

Motor and control cable ferrite cores j ATV66U41N4–D46N4, U41M2–D33M2 VW3A66470 30.ATV66D54N4–D79N4, D46M2 VW3A66471 36.

RFI filtersj

ATV66U41N4 (1-2 Hp) VW3A66401U 1409.ATV66U41N4 (3 Hp), U54N4 VW3A66402U 1520.ATV66U72N4–D12N4 VW3A66404U 1655.ATV66D16N4–D23N4 VW3A66405U 1901.ATV66D33N4–D46N4 VW3A66406U 2147.

Line reactors and other filters See Page 24-32 . . . . . .

are D Company or related companies.

For additional information, reference catalog number 8800CT9701 or D-Fax™ numbers 2586 through 2593.

ALTIVAR is a Registered Trademark of Squ

enengineering.com

-10 3/00

© 2000 Square DAll Rights Reserved

CP4C pCP4F DiscountSchedule

y of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stev

Page 3: ALTIVAR 66 Drive - Steven Engineering

Courtesy of Steve

Enclosed DrivesALTIVAR® 66

Class 8839

The Class 8839 ALTIVAR 66 enclosed AC drives are designed for flexibility to meet applications requiring additionalenclosure space for features such as line disconnects, meters, pilot devices, or isolation and bypass contactors. To selectan AC drive, identify the catalog number by Class, Type and Modification number(s) as shown below:

Standard AC Drive Includes:

Product

Code Enclosed Drive

66U ALTIVAR 66

�Horsepower

CodeHp rating

@208/230 V

460 V

CodeHp

rating@ 460 V

C 1 Hp Q 60 Hp

D 2 Hp R 75 Hp

E 3 Hp S 100 Hp

F 5 Hp T 125 Hp

G 7.5 Hp U 150 Hp

H 10 Hp W 200 Hp

J 15 Hp X 250 Hp

K 20 Hp Y 300 Hp

L 25 Hp Z 350 Hp

M 30 Hp 4 400 Hp

N 40 Hp

P 50 Hp

�Enclosure Type

Code EnvironmentRating

G Type 1

A Type 12

Power Circuit Description

Code with Bypass Code without Bypass

CSingle DisconnectIntegrated 2-contactors22,000 AIC rating

ANo DisconnectOptimized enclosure65,000 AIC rating

DSingle DisconnectIntegrated 2-contactors65,000 AIC rating

BDisconnectOptimized enclosure65,000 AIC rating

EDual DisconnectsBarriered 2-contactors22,000 AIC rating

GOutput contactorIntegrated enclosure65,000 AIC rating

FDual DisconnectsBarriered 2-contactors65,000 AIC rating

HLine contactorIntegrated enclosure65,000 AIC rating

IIsolation & transferIntegrated 2-contactors65,000 AIC rating

JSingle DisconnectIntegrated 3-contactors65,000 AIC rating

KSingle DisconnectIntegrated 3-contactors22,000 AIC rating

� Voltage Rating

Code Utilization/Distribution

2 200/208 Vac

3 230/240 Vac

4 460/480 Vac

�Application Type

Code Applied Rating

C Constant Torque

V Variable Torque

L Low Noise Variable Torque(1-75 Hp @ 460 V)

Class Type Number Modifications

8839 66U

� � � � � �

k Disconnect device with flange-mounted external Factory Modifications Include:

24A

C D

RIV

ES

operator interlocked with the door (except whenpower Circuit A is selected)

k Sensorless Flux Vector Technology

k Insulated Gate Bipolar Transistor (IGBT) with PWMoutput waveform

k 200,000 AIC current limiting line fuses installed

k Door mounted status lights; red fault LED, yellowcaution LED and green drive fail indiction

k UL 508C listed with NEMA ICS 7.1 compliance

k Type 1 or 12 enclosure

k Door mounted pilot devices and meters

k I/O extension module

k Line contactors

k Output contactors

k Isolation/bypass

k Factory engineered features

NOTE: All modifications follow specific interoperability rules for selection and configuration. Modification selection can be

validated at the time of quotation or order entry by Square D Q2C/Product Selector process.

ALTIVAR is a Registered Trademark of Square D Company or related companies.

11

ring.com

24-3/00

© 2000 Square DAll Rights Reserved

CP4C DiscountSchedule

n Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenenginee

Page 4: ALTIVAR 66 Drive - Steven Engineering

AC

DR

IVE

S

C

Enclosed DrivesALTIVAR® 66Class 8839

4

208/230 V and 460 V — Constant Torque Drives

2 = 208 V3 = 230 V4 = 460 V

Class 883l9 66U C

Style Hp Code Enclosure Voltage Torque PowerCircuit

Enclosures G =Type 1

A =Type 12

Hp @ 208/230 V Price Price1–10 Hp, CT Included $ 363.

15– 40 Hp, CT Included 850.Hp @ 460 V Price Price1–20 Hp, CT Included $ 363.

25–40 Hp, CT Included 850.50–75 Hp, CT Included 1213.

100–200 Hp, CT Included 6066.

Hp Code Drive and Power Circuits Priced with Type 1 Enclosures

Horsepower

Cont rollerOutp ut

Amperes

A B C D E F G H I J K

Code

@20

8/23

0V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

WithoutDisconnect

SingleDisconnect

Single Disconn ect,2-ContactorISO/Bypass

Dual Disconnect2-ContactorISO/Bypass

SingleDisconnect

OutputContactor

SingleDisconnect

InputContactor

SingleDisconn ect,2-ContactorISO/Transfer

Single Disconnect,3-ContactorISO/Bypass

Price Price Price Price Price Price Price Price Price Price Price

C 1 4.6 $ 3089. $ 4392. $ 6171. $ 6765. $ 6765. $ 8040. $ 4713. $ 4798. $ 6171. $ 8040. $ 6765.

D 2 7.5 3351. 4853. 6531. 7150. 7150. 8479. 5198. 5288. 6531. 8479. 7150.

E 3 10.6 4002. 5484. 7273. 7945. 7945. 9389. 5858. 5958. 7273. 9389. 7945.

F 5 16.7 4204. 5831. 7606. 8338. 8338. 9905. 6246. 6355. 7606. 9905. 8338.

G 7.5 24.2 5320. 7069. 8639. 9198. 9198. 10678. 7567. 7700. 8639. 10678. 9198.

H 10 30.8 6225. 7305. 9013. 9655. 9655. 11561. 7843. 7987. 9013. 11561. 9655.

J 15 46.2 6276. 7579. 9506. 10523. 10523. 12709. 8186. 8346. 9506. 12709. 10523.

K 20 59.4 7056. 8168. 10073. 11226. 11226. 13701. 8868. 9054. 10073. 13701. 11226.

L 25 74.8 7826. 9231. 11395. 12779. 12779. 15752. 10076. 10299. 11395. 15752. 12779.

M 30 88 9301. 10997. 13423. 15039. 15039. 18506. 11990. 12252. 13423. 18506. 15039.

N 40 114 14115. 16260. 18627. 20793. 20793. 25443. 17634. 17998. 18627. 25443. 20793.

Code

@ 460V 65 k AIC 65 k AIC 22 k AIC 65 k AIC 22 k AIC 65 k AIC 65 k AIC 65 k AIC 65 k AIC 65 k AIC 22 k AIC

C 1 2.1 2853. 3561. 4165. 4851. 4463. 5544. 3735. 3781. 4528. 5544. 4463.

D 2 3.4 2995. 3811. 4345. 5059. 4654. 5783. 3999. 4048. 4723. 5783. 4654.

E 3 4.8 3349. 4155. 4716. 5491. 5052. 6276. 4358. 4411. 5126. 6276. 5052.

F 5 7.6 3719. 4603. 5123. 5965. 5488. 6818. 4829. 4888. 5569. 6818. 5488.

G 7.5 11 4579. 5530. 5873. 6686. 6151. 7491. 5800. 5873. 6384. 7491. 6151.

H 10 14 5409. 5968. 6345. 7246. 6667. 8281. 6261. 6339. 6896. 8281. 6667.

J 15 21 5981. 6718. 7143. 8316. 7651. 9505. 7046. 7134. 7764. 9505. 7651.

K 20 27 7153. 7756. 8088. 9418. 8664. 10764. 8136. 8238. 8791. 10764. 8664.

L 25 34 8614. 9378. 9709. 11305. 10401. 12921. 9836. 9958. 10554. 12921. 10401.

M 30 40 10075. 10996. 11329. 13193. 12137. 15078. 11536. 11679. 12314. 15078. 12137.

N 40 52 14065. 15230. 15195. 17694. 16278. 20221. 15976. 16175. 16516. 20221. 16278.

P 50 65 16881. 18333. 17924. 20589. 18942. 23529. 19230. 19469. 19483. 23529. 18942.

Q 60 77 19390. 21036. 20515. 23606. 21718. 26978. 22068. 22340. 22299. 26978. 21718.

R 75 96 23101. 25125. 25042. 29161. 26828. 33326. 26355. 26683. 27220. 33326. 26828.

S 100 124 – 27639. 27518. 32044. 29480. 36620. 28993. 29351. 29911. – 29480.

T 125 156 – 32290. 32967. 38390. 35319. 43873. 33873. 34293. 35834. – 35319.

U 150 180 – 36715. 36514. 42519. 39117. 48593. 38514. 38991. 39689. – 39117.

W 200 240 – 43694. 45565. 53060. 48815. 60638. 45835. 46404. 49528. – 48815.

X 250 302 – 53904. – – – 75955. 64553. – 68313. – –

Y 300 361 – 59190. – – – 82494. 71092. – 76105. – –

Z 350 414 – 65366. – – – 89171. 78521. – 84787. – –

24

2

ourtes

For additional information, reference catalog number 8800CT9701 or D-FaxTM numbers 2586 through 2593.

ALTIVAR is a Registered Trademark of Square D Company or related companies.

enengineering.com

-12 3/00

© 2000 Square DAll Rights Reserved

CP4C DiscountSchedule

y of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stev

Page 5: ALTIVAR 66 Drive - Steven Engineering

Courtesy of Steve

Enclosed DrivesALTIVAR® 66

Class 8839

S

208/230 V and 460 V — Variable Torque Driv es

2 = 208 V3 = 230 V4 = 460 V

Class 8839 66U V

Style Hp Code Enclosure Voltage Torque PowerCircuit

Enclosures G =Type 1

A =Type 12

Hp @ 208/230 V Price Price1–10 Hp, VT Included $ 363.15–50 Hp, VT Included 850.Hp @ 460 V Price Price1–25 Hp, VT Included $ 363.30–50 Hp, VT Included 850.

60–100 Hp, VT Included 1213.125–200 Hp, VT Included 6066.

Hp Code Drive and Power Circuits Priced with Type 1 EnclosuresHorsepower

Cont rollerOutput

Amperes

A B C D E F G H I J K

Code

@20

8/23

0V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

WithoutDisconnect

SingleDisconnect

Single Disconn ect2-ContactorISO/Bypass

Dual Disconnect2-ContactorISO/Bypass

SingleDisconnect

Outputcont actor

SingleDisconnect

Inputcontactor

SingleDisconnect2-Cont actorISO/Transfer

Single Disconnect3-ContactorISO/Bypass

Price Price Price Price Price Price Price Price Price Price PriceC 1 4.6 $ 2808. $ 4040. $ 5725. $ 6288. $ 6288. $ 5725. $ 4344. $ 4424. $ 5834. $ 7493. $ 6288.D 2 7.5 3089. 4392. 6171. 6765. 6765. 7493. 4713. 4798. 6171. 8040. 6765.E 3 10.6 3351. 4853. 6531. 7150. 7150. 8040. 5198. 5288. 6531. 8479. 7150.F 5 16.7 3911. 5394. 7182. 7855. 7855. 8479. 5767. 5866. 7182. 9298. 7855.G 7.5 24.2 4204. 5831. 7606. 8338. 8338. 9298. 6246. 6355. 7606. 9905. 8338.H 10 30.8 5320. 7069. 8639. 9198. 9198. 9905. 7567. 7700. 8639. 10678. 9198.J 15 46.2 6276. 7305. 9013. 9655. 9655. 10678. 7843. 7987. 9013. 11561. 9655.K 20 59.4 6468. 7579. 9506. 10523. 10523. 11561. 8186. 8346. 9506. 12709. 10523.L 25 74.8 7056. 8168. 10073. 11226. 11226. 12709. 8868. 9054. 10073. 13701. 11226.M 30 88 7826. 9231. 11395. 12779. 12779. 13701. 10076. 10299. 11395. 15752. 12779.N 40 114 9301. 10997. 13423. 15039. 15039. 15752. 11990. 12252. 13423. 18506. 15039.P 50 143 14115. 16260. 18627. 20793. 20793. 25443. 17634. 17998. 18627. 25443. 20793.

Code@

460 V 65 k AIC 65 k AIC 22 k AIC 65 k AIC 22 k AIC 65 k AIC 65 k AIC 65 k AIC 65 k AIC 65 k AIC 22 k AICC 1 2.1 2700. 3370. 3942. 4591. 4224. 5246. 3535. 3578. 4344. 5246. 4224.D 2 3.4 2853. 3561. 4165. 4851. 4463. 5544. 3735. 3781. 4528. 5544. 4463.E 3 4.8 2995. 3811. 4345. 5059. 4654. 5783. 3999. 4048. 4723. 5783. 4654.F 5 7.6 3349. 4155. 4716. 5491. 5052. 6276. 4358. 4411. 5126. 6276. 5052.G 7.5 11 3719. 4603. 5123. 5965. 5488. 6818. 4829. 4888. 5569. 6818. 5488.H 10 14 4579. 5530. 5873. 6686. 6151. 7491. 5800. 5873. 6384. 7491. 6151.J 15 21 5409. 5968. 6345. 7246. 6667. 8281. 6261. 6339. 6896. 8281. 6667.K 20 27 5981. 6718. 7143. 8316. 7651. 9505. 7046. 7134. 7764. 9505. 7651.L 25 34 7153. 7756. 8088. 9418. 8664. 10764. 8136. 8238. 8791. 10764. 8664.M 30 40 8614. 9378. 9709. 11305. 10401. 12921. 9836. 9958. 10554. 12921. 10401.N 40 52 10075. 10996. 11329. 13193. 12137. 15078. 11536. 11679. 12314. 15078. 12137.P 50 65 14065. 15230. 15195. 17694. 16278. 20221. 15976. 16175. 16516. 20221. 16278.Q 60 77 16881. 18333. 17924. 20589. 18942. 23529. 19230. 19469. 19483. 23529. 18942.R 75 96 19390. 21036. 20515. 23606. 21718. 26978. 22068. 22340. 22299. 26978. 21718.S 100 124 23101. 25125. 25042. 29161. 26828. 33326. 26355. 26683. 27220. 33326. 26828.T 125 156 – 27639. 27518. 32044. 29480. 36620. 28993. 29351. 29911. – 29480.U 150 180 – 32290. 32967. 38390. 35319. 43873. 33873. 34293. 35834. – 35319.W 200 240 – 36715. 36514. 42519. 39117. 48593. 38514. 38991. 39689. – 39117.X 250 302 – 48767. – – – 67060. 58164. – 60670. – –Y 300 361 – 53904. – – – 75955. 64553. – 68313. – –Z 350 414 – 59190. – – – 82494. 71092. – 76105. – –4 400 477 – 65366. – – – 89171. 78521. – 84787. – –

24A

C D

RIV

E

For additional information, reference catalog number 8800CT9701 or D-FaxTM numbers 2586 through 2593.

ALTIVAR is a Registered Trademark of Square D Company or related companies.

13

ring.com

24-3/00

© 2000 Square DAll Rights Reserved

CP4C DiscountSchedule

n Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenenginee

Page 6: ALTIVAR 66 Drive - Steven Engineering

AC

DR

IVE

S

C

Enclosed DrivesALTIVAR® 66Class 8839

208/230 V and 460 V — Variable Torque, Low Nois e Drives

Note: Variable Torque Low Noise drives are typically used for HVAC fan and pump applications where motor noise could be objectionable.

2 = 208 V3 = 230 V4 = 460 V

Class 8839 66U L

Style Hp Code Enclosure Voltage Torque PowerCircuit

Enclosures G =Type 1

A =Type 12

Hp @ 208/230 V Price Price1–10 Hp, LN VT Included $ 363.15–40 Hp, LN VT Included 850.

Hp @ 460 V Price Price1–20 Hp, LN VT Included $ 363.25–40 Hp, LN VT Included 850.50–75 Hp, LN VT Included 1213.

HP Code Drive and Power Circuits Priced with Type 1 Enclosures

Horsepower

Cont rollerOutp ut

Amperes

A B C D E F G H I J K

Code

@20

8/23

0V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

5 k AIC/208 V

22 k AIC/230 V

WithoutDisconnect

SingleDisconnect

Single Disconn ect2-ContactorISO/Bypass

Dual Disconnect2-ContactorISO/Bypass

SingleDisconnect

Outp utContactor

SingleDisconnect

InputContactor

SingleDisconnect2-ContactorISO/Transfer

Single Disconn ect3-ContactorISO/Bypass

Price Price Price Price Price Price Price Price Price Price Price

C 1 4.6 $ 3089. $ 4392. $ 6171. $ 6765. $ 6765. $ 8040. $ 4713. $ 4798. $ 6171. $ 8040. $ 6765.D 2 7.5 3351. 4853. 6531. 7150. 7150. 8479. 5198. 5288. 6531. 8479. 7150.

E 3 10.6 4002. 5484. 7273. 7945. 7945. 9389. 5858. 5958. 7273. 9389. 7945.F 5 16.7 4204. 5831. 7606. 8338. 8338. 9905. 6246. 6355. 7606. 9905. 8338.

G 7.5 24.2 5320. 7069. 8639. 9198. 9198. 10678. 7567. 7700. 8639. 10678. 9198.H 10 30.8 6225. 7305. 9013. 9655. 9655. 11561. 7843. 7987. 9013. 11561. 9655.

J 15 46.2 6276. 7579. 9506. 10523. 10523. 12709. 8186. 8346. 9506. 12709. 10523.K 20 59.4 7056. 8168. 10073. 11226. 11226. 13701. 8868. 9054. 10073. 13701. 11226.

L 25 74.8 7826. 9231. 11395. 12779. 12779. 15752. 10076. 10299. 11395. 15752. 12779.M 30 88 9301. 10997. 13423. 15039. 15039. 18506. 11990. 12252. 13423. 18506. 15039.

N 40 114 14115. 16260. 18627. 20793. 20793. 25443. 17634. 17998. 18627. 25443. 20793.

Code @ 460 V 65 k AIC 65 k AIC 22 k AIC 65 k AIC 22 k AIC 65 k AIC 65 k AIC 65 k AIC 65 k AIC 65 k AIC 22 k AICC 1 2.1 2853. 3561. 4165. 4851. 4463. 5544. 3735. 3781. 4528. 5544. 4463.

D 2 3.4 2995. 3811. 4345. 5059. 4654. 5783. 3999. 4048. 4723. 5783. 4654.E 3 4.8 3349. 4155. 4716. 5491. 5052. 6276. 4358. 4411. 5126. 6276. 5052.

F 5 7.6 3719. 4603. 5123. 5965. 5488. 6818. 4829. 4888. 5569. 6818. 5488.G 7.5 11 4579. 5530. 5873. 6686. 6151. 7491. 5800. 5873. 6384. 7491. 6151.

H 10 14 5409. 5968. 6345. 7246. 6667. 8281. 6261. 6339. 6896. 8281. 6667.J 15 21 5981. 6718. 7143. 8316. 7651. 9505. 7046. 7134. 7764. 9505. 7651.

K 20 27 7153. 7756. 8088. 9418. 8664. 10764. 8136. 8238. 8791. 10764. 8664.L 25 34 8614. 9378. 9709. 11305. 10401. 12921. 9836. 9958. 10554. 12921. 10401.

M 30 40 10075. 10996. 11329. 13193. 12137. 15078. 11536. 11679. 12314. 15078. 12137.N 40 52 14065. 15230. 15195. 17694. 16278. 20221. 15976. 16175. 16516. 20221. 16278.

P 50 65 16881. 18333. 17924. 20589. 18942. 23529. 19230. 19469. 19483. 23529. 18942.Q 60 77 19390. 21036. 20515. 23606. 21718. 26978. 22068. 22340. 22299. 26978. 21718.

R 75 96 23101. 25125. 25042. 29161. 26828. 33326. 26355. 26683. 27220. 33326. 26828.

4

For additional information, reference catalog number 8800CT9701 or D-FaxTM numbers 2586 through 2593.

2

ALTIVAR is a Registered Trademark of Square D Company or related companies.

24

ourtes enengineering.com

-14 3/00

© 2000 Square DAll Rights Reserved

CP4C DiscountSchedule

y of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stev

Page 7: ALTIVAR 66 Drive - Steven Engineering

Courtesy of Steve

Enclosed DrivesALTIVAR® 66–Standard Modifications

Class 8839

24A

C D

RIV

ES

The available space for mounting meters and control devices on the drive door is dependent upon the meter and controloptions selected. The following space is available based on the combination of meters and control options:

MetersDigital and analog meters may be selected to provide indication of speed, amperes, volts or watts. These meters are inaddition to the door mounted keypad display. The keypad display has many of the following built in metering functions.

The Digital and Analog meter functions along with their alpha-numeric modifications are listed. These meters are doormounted on the control island with space for a maximum of two meters. When selecting meter(s), use selection 1 columnfor the first meter and selection column 2 for the second meter.

General Purpose Control DevicesThese door mounted operator controls provide digital and analog inputs for commanding drive speed and start/stopfunctions. The digital and analog input terminals are active only when the keypad is programmed for Terminal Mode ofoperation.

Meters Number of Spaces for Control Operators or Pilot Lights

0 8

1 6

2 4

Modifications

Digital & Analog Meter Functions Price

Sec

tion

1

Sec

tion

2

A07 A08 Analog percent speed meter scaled 0 to 120% of base speed $490.B07 B08 Analog percent current scaled 0 to 200% of rated output current 490.

C07 C08 Analog percent volts scaled 0 to 120% of rated output voltage 490.D07 D08 Analog percent power scaled 0 to 200% of rated output power 490.

E07 E08 Digital ammeter (amperes) scaled 0 to 2 times rated output amperes 573.F07 F08 Digital voltmeter (voltage) scaled 0 to 1.1 times rated output voltage 573.

G07 G08 Digital speed meter (frequency) scaled 0 to 72 Hz output frequency 573.H07 H08 Digital power meter (kilowatts/horsepower) scaled 0 to 2.0 times related output horsepower 573.

J07 J08 Digital percent current scaled 0 to 120% rated output current 573.K07 K08 Digital percent volts scaled 0 to 110% rated output voltage 573.

L07 L08 Digital percent speed scaled 0 to 120% of base speed 573.M07 M08 Digital percent power scaled 0 to 200% rated output power 573.

ModA09

Start/stop push buttons without manual speed potentiometer Price

Provides Start/Stop push buttons mounted on the door mounted control island. These pushbuttons control the starting andstopping of the connected motor. Speed may be adjusted by a remote manual speed potentiometer.Note: Use of the keypad to adjust speed is not possible when the start/stop pushbuttons are active in the terminal mode.

$214.

ModB09

Start/stop push buttons with manual speed potentiometer Price

Provides Start/Stop push buttons and manual speed potentiometer mounted on the door mounted control island. Thesepushbuttons control the starting and stopping of the connected motor. Speed may be adjusted by the door mounted manualspeed potentiometer.

$255.

ModC09qt

Start/stop push buttons, hand/auto selector switch without manual speed potentiometer Price

Provides Start/Stop push buttons and a Hand/Auto selector switch mounted on the door mounted control island. TheHand/Auto selector switch is used to select between the AI1 and AI2 analog inputs. In the Hand position the start/stop pushbuttons are active (3 wire control) and speed may be adjusted by a remote manual speed potentiometer. In the Auto positionthe AC drive may be started and stopped by a remote contact (user supplied) (2 wire control). The speed may be adjustedby a 4-20 madc signal to analog input reference AI2. The stop push button is active for both Hand and Auto modes.Note: Use of the keypad to adjust speed is not possible when the start/stop pushbuttons and Hand/auto switch are active inthe terminal mode.

$255.

ModD09q

Start/stop push buttons, Hand/auto selector switch with manual speed potentiometer Price

Provides Start/Stop push buttons, Hand/Auto selector switch and manual speed potentiometer mounted on the doormounted control island. The Hand/Auto selector switch is used to select between the AI1 and AI2 analog inputs. In the Handposition the start/stop push buttons are active (3 wire control) and speed may be adjusted by the manual speedpotentiometer. In the Auto position the AC drive may be started and stopped by a remote contract (user supplied) (2 wirecontrol). The speed may be adjusted by a 4-20 madc signal to analog input reference AI2. The stop push button is active forboth Hand and Auto modes.

$367.

ModE09ft

Stop pushbuttons and forward/reverse push buttons without manual speed potentiometer Price

Provides Stop, Forward and Reverse push buttons door mounted on the control island. Depressing the forward or reversepush button will start the motor in the desired direction. The stop push button will place the controller in the normal stopmode. The motor speed may be adjusted by a remote manual speed potentiometer or an external speed signal. Note: Useof the keypad to adjust speed is not possible when the stop push-button and forward/ reverse push-button is active in theterminal mode.

$255.

ALTIVAR is a Registered Trademark of Square D Company or related companies.

15

ring.com

24-3/00

© 2000 Square DAll Rights Reserved

CP4C DiscountSchedule

n Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenenginee

Page 8: ALTIVAR 66 Drive - Steven Engineering

AC

DR

IVE

S

C

Enclosed DrivesALTIVAR® 66–Standard ModificationsClass 8839

24

o

24

urtes

q If C09, D09, L09, or M09 general purpose pilot devices are selected for use with power circuits A or B, option board (A11) must be selected. (Included by factoryon power circuits C through K.)

f E09, F09, J09, K09 are not available with power circuits C, D, E, F, I, J, and K.t Requires user mounted manual speed potentiometer.

p Run/Jog selector switch (A10) only available when modifications A09, B09,C09, D09, E09 or F09 are selected.

u Jog push-button (C10) only available when modifications A09, B09, C09 orD09 are selected.

v Jog fwd and jog rev push-button (D10) only available when E09 or F09 areselected.

s Fwd/Rev selector switch (F10) only available when G09 or H09 areselected.

Mod A11 is included in Power Circuits C–K as standard hardware.

ModF09f

Stop pushbutton, forward and reverse push buttons with manual speed potentiometer Price

Provides Stop, Forward and Reverse push buttons and manual speed potentiometer door mounted on the control island.Depressing the forward or reverse push button will start the motor in the desired direction. The stop push button will placethe controller in the normal stop mode. The motor speed may be adjusted by the door mounted manual speedpotentiometer.

$367.

ModG09t

Run/stop selector switch without manual speed potentiometer Price

Provides a two position selector switch door mounted on the control island. Setting the switch in the run position will startthe motor. Setting the switch to the stop position will stop the motor. The motor speed may be adjusted by a remote manualspeed potentiometer or an external speed signal. Note: Use of the keypad to adjust speed is not possible when the run/stopselector switch is active in the terminal mode.

$144.

ModH09

Run/stop selector switch with manual speed potentiometer Price

Provides a two position selector switch and manual speed potentiometer door mounted on the control island. Setting theswitch in the runposition will start the motor. Setting the switch to the stop postion will stop the motor. The motor speed maybe adjusted by the door mounted manual speed potentiometer.

$255.

ModJ09ft

Forward-off-reverse selector switch without manual speed potentiometer Price

Provides a three position selector switch door mounted on the control island. Setting the switch either forward or reverse willstart the motor in the desired direction. The motor speed may be adjusted by a remote manual speed potentiometer or anexternal speed signal. Note: Use of the keypad to adjust speed is not possible when the forward-off-reverse selector switchis active in the terminal mode.

$179.

ModK09f

Forward-off-reverse selector switch with manual speed potentiometer Price

Provides a three position selector switch and manual speed potentiometer door mounted on the control island. Setting theswitch to either forward or reverse will start the motor in the desired direction. The motor speed may be adjusted by the doormounted manual speed potentiometer.

$260.

ModL09qt

Hand-off-auto selector switch without manual speed potentiometer Price

Provides a three position selector switch door mounted on the control island. The Hand-Off-Auto selector switch is used toselect between the AI1 and AI2 analog inputs. In the Hand position the motor will start and speed may be adjusted by aremote manual speed potentiometer. In the Auto position the motor may be started and stopped by a user supplied remotecontact. The speed may be adjusted by a 4-20 madc signal to analog input reference AI2. The off position will stop the motor.Note: Use of the keypad to adjust speed is not possible when the Hand-Off-Auto selector switch is active in the terminalmode.

$179.

ModM09q

Hand-off-auto selector switch without manual speed potentiometer Price

Provides a three position selector switch switch and manual speed potentiometer door mounted on the control island. TheHand-Off-Auto selector switch is used to select between the AI1 and AI2 analog inputs. In the Hand position the motor willstart and speed may be adjusted by a remote manual speed potentiometer. In the Auto position the motor may be startedand stopped by a user supplied remote contact. The speed may be adjusted by a 4-20 madc signal to analog input referenceAI2 or the door mounted manual speed potentiometer. The off position will stop the motor.

$260.

Special Purpose Control DevicesThese door mounted operator controls provide digitalinputs for jog and reversing functions.

ModA10p

Run-jog selector switch Price

Provides a two position selector switch switch for selectionof the start push-button to be a monetary contact (run) (3-wire control) or maintained contact (jog) (2-wire control).This selector switch is door mounted on the control island.

$144.

ModC10u

Jog push button Price

Provides a push button for jogging the connected motor.Refer to Instruction Manual VDOCO6S305 for informationconcerning the adjustment of job speed and cycle timer.This pushbutton is door mounted on the control island.

$97.

ModD10v

Fog forward and Jog reverse push buttons Price

Provides push buttons for jogging the connected motor inthe desired direction. Refer to Instruction ManualVDOCO6S305 for information concerning the adjustmentof job speed and jog cycle timer. These pushbuttons aredoor mounted on the control island.

$214.

ModF10s

Forward/reverse selector switch Price

Provides a two position selector switch to select the de-sired ddirectionof motor rotation. Refer to Instruction Man-ual VDOCO6S305– for information concerning speedreference inputs for the purpose of adjusting motor speed.This selector switch is door mounted on the control island.

$144.

I/O Extension ModuleWhen additional digital or analog inputs/outputs arerequired an I/O extension module may be selected.

ModA11

24 V I/O extension module Price

Provides additional 24 V digital/analog inputs and outputs

$380.• Four 24 Vdc digital logic inputs, LI5, LI6, LI7 and LI8• Two analog inputs AI3 (Differential) and AI4• Two relay outputs R3 and R4 (programmable)• One current loop output A03 (0-20 ma or 20-4 ma, 250W input impedance)

rk of Square D Company or related companies.

ALTIVAR is a Registered Tradema

enengineering.com

-16 3/00

© 2000 Square DAll Rights Reserved

CP4C DiscountSchedule

y of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stev

Page 9: ALTIVAR 66 Drive - Steven Engineering

Courtesy of Steve

Enclosed DrivesALTIVAR® 66–Standard Modifications

Class 8839

24A

C D

RIV

ES

Note: When power circuits C through K are selected an AFC Run (green) andBypass Run (amber) pilot light is provided on the door mounted bypasscontrol island as standard hardware.

Dynamic Braking

When the motor along with its connected mechanical load must be stopped faster than the normal coast time, the dynamicbraking modification should be selected.

ModD15

Dynamic BrakingHorsepower

Price460 V Constant Torque Variable Torque Low Noise up to 75 Hp 460 V Variable Torque

Provides a resistor and overloadprotection mounted in a self ventilatedenclosure mounted on top of the driveenclosure. This resistor will absorb theregenerative energy from an AC motorto provide internal braking action.

1 Hp to 5 Hp 1 Hp to 7.5 Hp $ 422.7.5 Hp and 10 Hp 10 Hp and 15 Hp 633.15 Hp and 20 Hp 20 Hp and 25 Hp 950.25 Hp to 40 Hp 30 Hp to 50 Hp 1266.50 Hp 60 Hp 1846.60 Hp and 75 Hp 75 Hp and 100 Hp 2321.100 Hp to 200 Hp 125 Hp to 200 Hp 2743.250 Hp to 350 Hp 250 Hp to 400 Hp 5866.

Miscellaneous Modifications

These modifications provide a variety of functions to meetcertain application requirements. This extra flexibility offersthe ultimate in Build to Order capacity of an AC Drive.

ModA16

‘Power on’ red pilot light Price

Provides a red pilot light that illuminates when power isapplied to the drive. This pilot light is an LED type doormounted on the control island.

$97.

ModB16q

‘Fault’ yellow pilot light Price

Provides a yellow pilot light that illuminates when the driveis faulted. This pilot light is an LED type door mounted onthe control island.

$97.

ModC16c

‘Jog’ green pilot light Price

Provides a green pilot light that illuminates when the jogpush-button is depressed on the drive. This pilot light is anLED type door mounted on the control island.

$97.

ModD16

‘Run’ green pilot light Price

Provides a green pilot light that illuminates when the driveis supplying an output frequency to the connected motor.This pilot light is an LED type door mounted on the controlisland.

$97.

ModE16f

‘Hand and auto’ yellow pilot lights Price

Provides two yellow pilot lights that illuminate when HANDor AUTO mode have been selected. These pilot lights areof the LED type door mounted on the control island.

$194.

ModF16p

‘Forward and reverse’ green pilot lights Price

Provides two green pilot lights that illuminate when theFORWARD or REVERSE mode has been selected.These pilot lights are of the LED type door mounted on thecontrol island.

$194.

ModG16l

‘Fault’ yellow pilot light with reset push button Price

Provides an illuminated push-button with a yellow lens thatilluminates when the drive is faulted. This illuminatedpush-button is an LED type door mounted on the controlisland. Once the condition which initiated the fault hasbeen corrected, the drive may be reset by depressing thepush button and the yellow light will extinguish. The faultsthat are re-setable with this modification are:• Undervoltage• Motor Overload• Input Phase Loss• Loss of Follower• Drive Over temperature• DC Bus Overload• Overvoltage

$194.

ModH16su

Bypass 3 wire control Price

Provides start/stop pushbuttons (3-wire control) forbypass contactor operation. These pushbuttons are doormounted on the bypass control island. Upon loss ofpower, the bypass operation must be restarted using themomentary start push button.

$194.

ModJ16au

Bypass duty cycle timer Price

Prevents rapid cycling of line power to the motor whenoperating in bypass mode. When line power is removedfrom the motor, line power cannot be reapplied in thebypass mode until the time delay set on the CTR relaytimer. The CTR relay timer is factory set for 10 seconds. Itcan be adjusted to meet user’s process requirementswithin the range of 10 to 180 seconds.

$158.

ModK16

Automatic transfer to bypass Price

Provides an automatic transfer to bypass for full speedopertion, should a fault condition occur tripping the driveoff line.

$151.

ModL16

Additional control VA Price

Increases the standard control transformer by 50 VAbeyond that required for operation of the control functions. $243.

ModM16h

Power Isolator controls Price

Provides two pushbuttons (3-wire control) for manualoperation of the line contactor. The two push buttons arelabeled CONVERTER PWR ENABLE andCONVERTER PWR DISABLE. These pushbuttons aredoor mounted on the bypass control island.

N/C

ModO16k

Oversized enclosure(50–75 Hp CT/60–100 Hp VT only) Price

Provides a 90"H x 32"W x 20"D freestanding enclosure forsubstitution of the standard 42"H x 32"W x 20"D wallmounted enclosure.

$534.

ModP16a

Auto start relay Price

Provides an interface for remote contact (120 V rated) tostart the drive or bypass and Hand/Auto selector switch forthe bypass. The Hand/Auto selector switch provides handor auto operation in the bypass mode with extraterminal points for user supplied float switches and otherlevel alarm functions.

$153.

ModQ16j

3-15 PSI input follower Price

Provides a 3-15 PSI follower from the users pneumaticsource. The motor speed will be proportional to the 3-15PSI pneumatic signal.

$842.

ModR16v

Convert pilot light(s) to push-to-test Price

Provides push-to-test of all pilot lights selected previously,except the Power On Pilot Light (A16).

$61.each

ModS16

24 Vdc power supply Price

Provides an auxiliary 24 Vdc, 320 mA power supply,installed within the drive. May be used to power devicesthat exceed the rating of the drive 24 Vdc supply.

$334.

ModT16d

Motor Elapsed Timer Meter (ETM) Price

Provides elapsed time indication of motor opertion fromboth drive and bypass contactor functions. The MotorElapsed Time meter is a 0 to 99999.9 digit in HOURS,non-resettable display rated 120 Vac, 60 Hz with a NEMAType 12 sealed face. This meter is door mounted on thecontrol island.

$245.

ModW16t

‘Fast stop’ push button Price

Provides a pushbutton for modifying the set decelertionramp rate to the minimum ramp rate of 0.1 seconds. Thispushbutton is door mounted on the control island. Thisfunction will allow the drive to decelerate the motor asquickly as possible within the operating limits of thecontroller configuration (braking selection) withoutcausing nuisance tripping.

$97.

ModY16

Omit door mounted keypad Price

Removes the keypad and LED display from outside theenclosure door. The keypad will remain on the basic driveunit within the enclosure.

-$100.Deduct

,

,

t

,

ALTIVAR is a Registered Trademark of Square DCompany or related companies.

q B16 yellow fault pilot light notavailable with G16.

c C16 green jog pilot light availablewhen special purpose pilotdevices A10, C10 and D10 areselected.

f E16 yellow hand/auto pilot lightsand P16 auto start relay onlyavailable if general purposedevices are: C09, D09, L09 orM09. If meters or F16 green fwd/rev pilot light is used E16 is notavailable.

p F16 green forward reverse pilotlights only available if generalpurpose devices are: E09, F09,J09, K09 or if special purposepilot device is an F10. If metersare used F16 is not available.

l G16 yellow fault pilot light andreset button not compatible withB16.

j Q16 3–15 PSI follower notavailable when general purposedevices are: B09, F09, H09 orK09, or units rated 1–20 Hp CTand LNVT and 1–25 Hp VT oncircuits H, J and K.

v R16 push to test pilot devicesavailable only for B16, C16, D16,E16, F16 or G16, also add $106.if used with power circuits C, D, EF, I, J and K.

a A09, B09, C09 or D09 generalpurpose devices are not availablewhen miscellaneous options areJ16, K16 or P16.

s J16 bypass duty cycle timer K16auto bypass and P16 auto startrelay not available with miscella-neous option H16 bypass 3 wire.

d T16 motor elapsed time meter noavailable withpower circuits A andB or if M16 is used.

k O16 oversized enclosureavailable only for 50, 60 and75 Hp, constant torque and lownoise variable torque, or 60, 75and 100 Hp, variable torque.

h M16 power isolator controlstandard with power circuits H, Jand K. M16 modmust be includedfor these power circuits.

u H16 bypass 3 wire, J16 bypasstimer and K16 auto bypass, onlyavailable with power circuits C, DE, F, I, J and K.

t W16 fast stop push button onlyavailable with general purposedevices, A09, B09, C09, D09, E09and F09.

17

ring.com

24-3/00

© 2000 Square DAll Rights Reserved

CP4C DiscountSchedule

n Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenenginee

Page 10: ALTIVAR 66 Drive - Steven Engineering

AC

DR

IVE

S

C

Enclosed DrivesALTIVAR® 66–Engineered ModificationsClass 8839

24

24

ourtes

Factory Engineered Modifications

Control OptionsForm modifications within the Q200 series will covercontrol circuit engineered features for the Class 8839enclosed drive controller.

Rules: 1. Available on all configurations.

Rules: 1. Available only for Power Circuits C,D,E,F,I,J or K.

Rules: 1. Available on all configurations.

Rules: 1. Available on all configurations.

Specify VA requirements at time of order entry in the ‘Engineering Notes’ fieldwithin Q2C.

Rules: 1. Available on all configurations.

Rules: 1. Available on all configurations.

Rules: 1. Available on configurations except Power Circuit A.

Rules: 1. Available on all configurations.2. Not available if option Q208 is selected.

Rules: 1. Available on all configurations.2. Not available if option Q207 is selected.

Rules: 1. Available on all configurations.2. Not available if option Q210 is selected.

Rules: 1. Available on all configurations.2. Not available if option Q209 is selected.

Rules: 1. Available on all configurations.2. Not available if option Q212 is selected.

Rules: 1. Available on all configurations.2. Not available if option Q211 is selected.

Customer supplies relay. Details concerning type must also be provided attime of order entry in the ‘Engineering Notes’ field within Q2C.

Rules: 1. Available on all configurations.2. Not available if option Q214 is selected.

Details concerning type must be provided at time of order entry in the ‘Engi-neering Notes’ field within Q2C.

Rules: 1. Available on all configurations.2. Not available if option Q213 is selected.

Rules: 1. Available on all configurations.2. Maximum of (6) operators per control station.

Rules: 1. Available for Power Circuits E and F only.

ModQ200

Auxiliary drive run contacts Price

Provides (3) Form ‘C’ contacts rated 5A @ 120 Vac wiredto terminal blocks (9080 GM6) for customer use. $ 276.

ModQ201

Auxiliary bypass run contacts Price

Provides (3) Form ‘C’ contacts rated 5A @ 120 Vac wiredto terminal blocks (9080 GM6) for customer use. $ 276.

ModQ202

Auxiliary drive fail contacts Price

Provides (3) Form ‘C’ contacts rated 5A @ 120 Vac wiredto terminal blocks (9080 GM6) for customer use. $ 276.

ModQ203

Auxiliary auto mode contacts Price

Provides an auxiliary AFC mode (auto) contact which willenergize a relay with (3) Form ‘C’ contacts rated 5A @120 Vac wired to terminal blocks (9080 GM6) for custom-er use.

$ 276.

ModQ204

Motor space heater Price

Provides control circuit contacts, 120 V, 150-500 VA sup-ply and fusing wired to terminals for customer use. $546.

ModQ205

Signal loss follower option board Price

Provides the 52010-055-50 intended for 4-20 mAdccontrol loop applications where upon the loss of inputsignal it is desired to retain the output signal at the lastinput signal level. The module provides isolated 4-20mAdc to 0-10 Vdc conversion and a normally open alarmrelay contact for signal loss alert. The module operatesfrom +24 Vdc power supply and is mounted on a stan-dard 35 mm DIN rail within the drive enclosure.

$ 460.

ModQ206

Emergency power off push-button Price

Provides a shunt trip modified molded case switch orcircuit breaker where a push-pull maintained mushroomhead push-button energizes the shunt trip coil andinstantaneously opens to shut down power supplied tothe drive controller in theAFC mode and/or bypass mode,coasting to an uncontrolled stop.

$ 316.

ModQ207

Inhibit/shutdown sequence(instantaneous operation) Price

Provides a relay circuit operating in the fail safe modewhere a remote initiating contact opens the relay,deenergizes and instantaneously shuts the AC drivedown in the AFC mode (hand or auto) and/or in thebypass mode (hand or auto).

$276.

ModQ208

Inhibit/shutdown sequence (timed operation) Price

Provides a relay circuit operating in the fail safe modewhere a remote initiating contact opens the relay,deenergizes and after a specified time shuts the AC drivedown in the AFC mode (hand or auto) and/or in thebypass mode (hand or auto).

$460.

ModQ209

Check valve sequence (gravity type) Price

Provides relay circuitry sequenced from a check valvelimit switch. A valve closed position limit switch willenergize the relay that will give a run permissive to thedrive controller in the AFC mode (hand or auto) and/or inthe bypass mode (hand or auto). A valve closed positionlimit switch will deenergize a timer relay such that if thisrelay is notdeenergizedwithin a specified time period, theAC drive will shut down in the AFC mode (hand orauto) and/or in the bypass mode (hand or auto).

$460.

ModQ210

Check valve sequence (motorized type) Price

Provides relay circuitry sequenced from a check valvelimit switch. A valve closed position limit switch willenergize relays that will initiate a remote valve operatingsolenoid limited to 50 VA and give a run permissive to theAC drive in the AFC mode (hand or auto) and/or in thebypass mode (hand or auto). A valve closed position limitswitch will deenergize a timer relay such that if this relayis not deenergized within a specified time period, the ACdrive will shut down in the AFC mode (hand or auto)and/or in the bypass mode (hand or auto).

$610.

ModQ211

Seal water solenoid – without pressure switchfeedback Price

Provides relay which will energize a remote seal watersolenoid limited to 50 VA during AC drive operation in theAFC mode (hand or auto) and/or in the bypass mode(hand or auto).

$610.

ModQ212

Seal water solenoid – with pressure switch feedback Price

Provides relay which will energize a remote seal watersolenoid limited to 50 VA duringdrivecontroller operation.Additionally, the remote initiating contact will open therelay, deenergizing and after a specified time shuts thedrive controller down in the AFC mode (hand or auto)and/or in the bypass mode (hand or auto).

$920.

ModQ213

Moisture detection relay circuit (without relay) Price

Provides 24 V or 120 V control power to a moisturedetection relay device, either electronic orelectro-mechanical prewired with socket or mountingspace only.

$316.

ModQ214

Moisture detection relay circuit (with relay) Price

Provides 24 V or 120 V control power to a moisturedetection relay device, either electronic orelectro-mechanical mounted and prewired.

$1035.

ModQ215

Substitute Type K operators Price

Provides Class 9001 Type K 30 mm heavy dutymultifunction operators in lieu of standard Telemecanique22 mm (XA2B/XB2B) pilot devices.

$282.

ModQ216

Substitute NEMA rated control relays Price

Provides NEMA type control relays in lieu of standard IECrated devices used on standard configurations. $475.

ALTIVAR is a Registered Trademark of Square D Company or related companies.

enengineering.com

-18 3/00

© 2000 Square DAll Rights Reserved

CP4C DiscountSchedule

y of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stev

Page 11: ALTIVAR 66 Drive - Steven Engineering

Courtesy of Steve

Enclosed DrivesALTIVAR® 66–Engineered Modifications

Class 8839

24A

C D

RIV

ES

Specify lens cap colors desired at time of order entry in ‘Engineering Notes’field within Q2C.

Rules: 1. Available on all configurations.

Rules: 1. Available on all configurations.

Rules: 1. Available on all configurations.2. Not available if option Q220 or Q221 is selected.

Rules: 1. Available on all configurations.2. Not available if option Q219 or Q221 is selected.

Rules: 1. Available on all configurations.2. Not available if option Q219 or Q220 is selected.

User supplies trunk cable dependent upon installation. Programming andsetup is required by user.

Rules: 1. Available on all configurations.2. Requires option A11.

Rules: 1. Available on all configurations.

Rules: 1. Available on all configurations.

Specify RTD values at time of order entry in ‘Engineering Notes’ field withinQ2C.

Rules: 1. Available on all configurations.2. Not available if option Q226 is selected.

Rules: 1. Available on units rated 250 Hp and up.2. Not available if option Q225 is selected.

Specify function at time of order entry in ‘Engineering Notes’ field within Q2C.Rules: 1. Available on all configurations.

Rules: 1. Available on all configurations.

Rules: 1. Available on all configurations.

Rules: 1. Available on Power Circuits C,D,E,F,G,I,J and K only.2. Must include option S16.

Enclosure and MiscellaneousModifications

Form modifications within the Q300 series will coverenclosure and miscellaneous enclosed features for theClass 8839 enclosed drive controller.

Specify legend, black letters/white background or white letters/black back-ground at time of order entry in ‘Engineering Notes’ field within Q2C.

Rules: 1. Available on all configurations.

Rules: 1. Available on all configurations.

Rules: 1. Available only on 250–400 Hp @ 460 V units.

ModQ217

Substitute pilot light lens color(s) Price

Provides the flexibility to configure lens cap colors tocontract equipment designations. N/C

ModQ218

Blown fuse indictors on control fuses Price

Provides blown circuit fuse indicators on control circuitfuses in lieu of standard fuses. $575.

ModQ219

PowerLogic® power meter display Price

Provides a Class 3020 PM-620 Power module true rmsmeter display with basic instrumentation, demand, THD,date/time stamping, neutral current, factory mounted andwired.

$1564.

ModQ220

CM-2250 PowerLogic® circuit monitor Price

Provides a Class 3020 CM-2250 circuit monitor displaywith instrumentation, 0.2% accuracy, data logging andwaveform capture, factory mounted and wired. IncludesPT’s and CT’s.

$4449.

ModQ221

CM-2350 PowerLogic® circuit monitor Price

Provides a Class 3020 CM-2350 circuit monitor displaywith instrumentation, 0.2% accuracy, data logging andwaveform capture, factory mounted and wired. IncludesPT’s and CT’s.

$5229.

ModQ222

ModBus Plus® communications Price

Provides the VW3-A66305U ModBus Plus( PCMCIAcommunication card kit with factory installed carrier andcard only. Drop cable and tap is provided in box for userinstallation.

$660.

ModQ223

Adjustable on delay timer Price

Provides an adjustable On Time Delay Relay for powerup restart function, mounted and wired for AFC mode(hand or auto) mode and/or in the bypass mode (hand/auto).

$144.

ModQ224

Motor overtemperature logic input Price

Provides dedicated terminals using an external motorovertemperature input (N.C. contact) factory wired andprogrammed.

$86.

ModQ225

RTD inputs (motor protection alarm) Price

Provides capability for accepting up to (3) RTD inputsmaximum using an RTD limit alarms, factory mountedand wired.

$1293.

ModQ226

Motor management relay Price

Provides motor protection and metering functions usingthe GE/Multilin 469 motor management relay. This relayprovides protection for motor and load conditions:overload, differential, stator temperature, high inertialoads, undercurrent, underpower, jam and bearingovertemperature. The motor management relay is facto-ry mounted and wired. Includes PT’s and CT’s.

$9177.

ModQ227

Local/remote selector switch Price

Provides an additional (2) position selector switch with orwithout auxiliary relay(s) for selection of one of thefollowing modes:• Hand/Auto or Hand/Off/Auto selector switch.• Speed reference (either speed potentiometer or auto

signal).• Start/Stop pushbuttons (stop is active for both modes).

$282.

ModQ228

Spare terminal blocks (unwired) Price

Provides (10) spare terminal blocks 'unwired' for custom-er use using the Class 9080 Type G series terminals. $290.

ModQ229

Smoke purge Price

Provides capability to run drive and/or bypass at fullspeed operation based upon contact closure or signalfrom remote source. Commonly specified for building firecode requirements on HVAC projects.

$200.

ModQ230

Riley current transducer Price

Provides a precision, high quality AC current sensor formonitoring AC motor currents and transmits continuousreadings via a 4-20 mA dc output signal. This modelcombines the function of a CT and a transducer in onecompact unit . This unit is an isolated, two wire transmit-ter that requires option S16 to excite the transducer.

$920.

ModQ300

ID engraved nameplates Price

Provides a lamacoid nameplate, engraved withequipment designation.ne compact unit. $40.

ModQ301

Permanent wire markers Price

Provides permanent type wire markers on control wiringassemblies. $437.

ModQ302

Fan filter assembly Price

Provides fan filter assembly factorymounted on 250–400 Hp @ 460 V units only. $506.

ALTIVAR is a Registered Trademark of Square D Company or related companies.

Discount

19

ring.com

24-3/00

© 2000 Square DAll Rights Reserved

CP4C Schedule

n Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenenginee

Page 12: ALTIVAR 66 Drive - Steven Engineering

AC

DR

IVE

S

C

Enclosed DrivesALTIVAR® 66–Engineered ModificationsClass 8839

24

24

ourtes

Rules: 1. Available on all configurations.2. Not available if option Q304 is selected.

Rules: 1. Available on all configurations.2. Not available if option Q303 is selected.

Rules: 1. Available on configurations up to 75 Hp Constant Torque (LowNoise VT) or 100 Hp Variable Torque.2. Not compatible with form O16.

Power OptionsForm modifications within the Q400 series will coverengineered power circuit configurations for the Class 8839enclosed drive controller.

Rules: 1. Not available if options D15 or Q401 is selected.

Rules: 1. Not available if option D15 or Q400 is selected.2. Q401 available offering is for 460 V rated units only up to 75 Hp CT/LN (100 Hp VT).3. Not available for 208 V and 230 V ratings.

Note: Devices rated 250–400 Hp @ 460 V use NEMA rated contactors asstandard.

Rules: 1. Available for Power Circuits E and F only.

Rules: 1. Available on all configurations.

Note: MOVs are standard hardware on devices rated up to 75 Hp CT (100Hp VT); 1000 V (breakover voltage), 230 joules.

Rules: 1. Available on all configurations.

Note: The sum of the total connected motors must not exceed the drivecontroller full load ampere rating. UL Label is voided; a UL Panel-builders label will be supplied. Specify motor FLA values at time oforder entry in ‘Engineering Notes’ field within Q2C.

Rules: 1. Available on all configurations.2. Not available if option Q406 is selected.

Note: Specify mode of operation via “Motor A-OFF-Motor B” selector switch,remote contact closure or rotation timer scheme at time of order entryin ‘Engineering Notes’ field within Q2C.

Rules: 1. Available on all configurations.2. Not available if option Q405 is selected.

Rules: 1. Available on Power Circuits C,D,E,F,G,I,J and K only.

ModQ303

ANSI#49 enclosure paint Price

Provides option to configure enclosure paint to industrystandard ANSI#49 gray paint in lieu of RAL 7032 (Beige). $316.

ModQ304

ANSI#61 enclosure paint Price

Provides option to configure enclosure paint to industrystandard ANSI#61 light gray paint in lieu of RAL 7032(Beige).

$316.

ModQ305

Free standing conversion Price

Converts all standard wall mounted configurations up to100 Hp using the Class 8839 FSK4 or FSK5 floor standkit, factory installed.

$805.

ModQ400

Top mounted5% LineReactor

Horsepower

460 V Ratings Price 208/230 VRatings Price

Provides afactorymounted andwired 5%impedance linereactor tomitigate har-monic distortion(IEEE 519) backonto the AC line.

1–3 $ 748. 1–3 $748.

5–7.5 863. 5–10 863.

10–15 909. 15 958.

20–25 1005.20–25 (208 V)

and30 (230 V)

1346.

30–40 1380.30–40 (208 V)

and40–50 (230 V)

1601.

50–60 1558. 50 (208 V) 1762.

75 1672.

100(VT only) 1819.

100(CT only)–125 2067.

150 2292.

200 3111.

ModQ401

Top mounted motorprotecting filter

Horsepower

Price460 V Ratingsonly

Provides a factory mounted andwired dv/dt filter on the drive outputfor long motor lead lengthsconsiderations in excess of ourpublished guidelines, up to1000 feet.

1–57.5–2530–4050–60

75100 (VT only)

$1265.1438.1840.2128.2588.2795.

ModQ402

NEMA ratedcontactors Horsepower

Provides NEMArated contactors forisolation andbypassconfiguration inlieu of the IEC ratedcontactors.

460 VRatings Price 208/230 V

Ratings Price

1–3 $ 1152. 1–3 $1725.

5–10 1449. 5–7.5 2013.

15–20 1840. 10–15 2415.

25–30 2530. 20–25 2875.

40–50 4025. 30 3450.

60 4600. 40–50 4830.

75–100 6325.

125 7705.

150 8510.

200 10580.

ModQ403

380 V/50 Hz system configuration Price

Provides device modifications to control power transform-er, power contactors (when provided) and firmware config-uration to 380 V/50 Hz utilization voltage and altersnameplate rating to reflect "KW" in lieu of Hp ratings.

$575.

ModQ404

Secondary surge arrester Price

Provides supplementary MOV protection using a Class6671 SDSA3650 SURGEBREAKER™ Secondary SurgeArrester hard-wired and factory mounted.

$385.

ModQ405

Dual motor overloads and branchshort circuit protection Horsepower Price

Provides short circuit and overloadprotection for (2) motors connected to theoutput of the drive controller. Includesoverload modules for each motor; ratedfuse blocks and fuses (if bypass issupplied).

1–1015–2530–50

60–100125–200

$642.698.786.

1100.3260.

ModQ406

Motor A or B contactor scheme Horsepower Price

Provides a contactor interlocked for theselection of one motor for load share viaa selector switch or rotation timerscheme.

1-10 Hp15-25 Hp30-50 Hp60-100 Hp

125-200 Hp250-400 Hp

$ 1169.1675.2176.4891.

10270.22549.

ModQ407

Substitute Class 20 overloads Price

Provides a Class 20 overload in lieu of standard Class 10bimetallic. $155.

ALTIVAR is a Registered Trademark of Square D Company or related companies.

enengineering.com

-20 3/00

© 2000 Square DAll Rights Reserved

CP4C DiscountSchedule

y of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stev

Page 13: ALTIVAR 66 Drive - Steven Engineering

3/00

Class 8839 ALTIVAR 66 Type CPD–

Courtesy of Steven Engineering, Inc. ! 230 Ryan W

Enclosed DrivesALTIVAR® 66 Type CPD

Class 8839

ES

200 Hp VT with POWERLOGIC ® circuit monitor shown.

ay, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-

AC Drives and Power Quality Solutions are now thesame Product! ALTIVAR® 66 Type CPD AC Drivesprovide integrated power quality solutions for customerswho require the most effective means of harmonicmitigation available in the industry. Utilizing an 18 Pulseconverter design, the ALTIVAR 66 Type CPD drivemaintains minimal AC line distortion for adjustablefrequency controllers rated 100 Hp and above. Thisproduct is strategically designed to help the user complywith IEEE 519 guidelines.

Ideal for pump and fan applications, the ALTIVAR 66 TypeCPD is available in variable and constant torque ratings.Designed for maximum flexibility, the ALTIVAR 66 TypeCPD drive will be offered with and without bypass,standard options and common control strategies.

Horsepower Offer

k 100–350 Hp (CT rating)

k 125–400 Hp (VT rating)

Enclosure Type

k Type 1 General Purpose

k Type 1 General Purpose with fan filters

k Floor mount construction

Voltage Rating

k 460 V ± 10%

Applied Rating

k Constant Torque (150% current limit)

k Variable Torque (110% current limit)

Power Circuit Configuration

k B: Disconnect means only

k D: Integrated Isolation and Bypass contactors

Standard Features

k 65,000 AIC short circuit coordinated rating toUL508C

k Phase Monitor relay

k Door mounted keypad display with indicators

k Industrial control operators

k Standard factory options

Engineered Modifications

k Customer specific requirements

Contact your nearest Square D/Schneider Electricsales office for availability and pricing.

24A

C D

RIV

ALTIVAR and POWERLOGIC are Registered Trademarks of Square D Company or related companies.

24-21© 2000 Square D

All Rights Reserved

9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com