Home About Disclaimer Engineering Videos Automation Videos Aircraft Videos Industrial Processing Photo Gallery Categories Ebooks Buku Automation buku engineering buku gratis Buku Kedokteran Buku Komputer buku listrik Buku PLC buku scada Travel Book Travel Guide tugas akhir Engineering Aircraft Engineering Arsitektur Engineering Automation Engineering Chemical Engineering Civil Engineering Computer Engineering Electrical Engineering Environment Engineering Food Engineering Highway Engineering Industrial Engineering Information Technology Interior Engineering IT Engineering Rockwell PLC : Blog Dunia Engineering Indonesia http://duniaengineering.mekarraya.com/?cat=99 1 de 21 02/06/2011 01:48 p.m.

Transcript of Allen Bradley Micrologix 1100 Ethernet Configuration

Page 1: Allen Bradley Micrologix 1100 Ethernet Configuration

HomeAboutDisclaimerEngineering Videos

Automation VideosAircraft VideosIndustrial Processing

Photo GalleryCategories

EbooksBuku Automationbuku engineeringbuku gratisBuku KedokteranBuku Komputerbuku listrikBuku PLCbuku scadaTravel BookTravel Guidetugas akhir

EngineeringAircraft EngineeringArsitektur EngineeringAutomation EngineeringChemical EngineeringCivil EngineeringComputer EngineeringElectrical EngineeringEnvironment EngineeringFood EngineeringHighway EngineeringIndustrial EngineeringInformation TechnologyInterior EngineeringIT Engineering

Rockwell PLC : Blog Dunia Engineering Indonesia http://duniaengineering.mekarraya.com/?cat=99

1 de 21 02/06/2011 01:48 p.m.

Page 2: Allen Bradley Micrologix 1100 Ethernet Configuration

Machine EngineeringMaintenance EngineeringMechanical EngineeringNuclear EngineeringPharmaceutical EngineeringSafety EngineeringScience and Engineering

Engineering SoftwareAcronis True ImageAutocadEplan ElectricMicrosoft Virtual PCMSSQLMySQL

Generalgratisanproject managementTanya?TeknologiTeknologi masa depanTeknologi Militerteknologi roboticatips and trik

PLCAB PLCAllen BradlleyAplikasi PLCAutomation ProtocolsBasic PLCbuku training siemens gratisCX-One DownloadDP/DP couplerinterface cable plcinverterManual Book PLCmodiconomron plcPassword ProtectionProfibus

Rockwell PLC : Blog Dunia Engineering Indonesia http://duniaengineering.mekarraya.com/?cat=99

2 de 21 02/06/2011 01:48 p.m.

Page 3: Allen Bradley Micrologix 1100 Ethernet Configuration

rockwell automationrsemulatorrslink

Rockwell PLCunlock block programwonderware

plc softwarePLC Software DownloadUncategorized

Basic KnowledgeData backupDisk image

Allen Bradley Micrologix 1100 Ethernet Configuration

Posted by admin on April 8, 2009 · Leave a Comment

Before we can connect to the Micrologix 1100 through the Ethernet port we must assign it an initial IP address. There are two ways to do this.

Go online with the Micrologix through the serial port and configure it. For this method see the “Micrologix 1100 Serial Configuration” article,follow the instructions, then come back to this article.

1.

Use a BootP or DHCP server – RsLinx comes with a BootP server so below is an example of configuring it with the BootP server that youshould already have

2.

Connect your Micrologix 1100 and your PC to an Ethernet switch1.Go to Start Menu > Rockwell Software > BOOTP-DHCP Server and select the program BOOTP-DHCP Server. Your shortcut may varyon your computer but this is the default for this shortcut.

2.

Rockwell PLC : Blog Dunia Engineering Indonesia http://duniaengineering.mekarraya.com/?cat=99

3 de 21 02/06/2011 01:48 p.m.

Page 4: Allen Bradley Micrologix 1100 Ethernet Configuration

Within a few seconds you will see your device begin to make requests for an address3.

Rockwell PLC : Blog Dunia Engineering Indonesia http://duniaengineering.mekarraya.com/?cat=99

4 de 21 02/06/2011 01:48 p.m.

Page 5: Allen Bradley Micrologix 1100 Ethernet Configuration

Select one of the requests out of the “Request History” and press the “Add to Relation List.” Enter the IP Address you wish toassign to the device and press OK For this example the IP Address is 192.168.210.100 but yours will be different depending on yournetwork configuration

4.

Rockwell PLC : Blog Dunia Engineering Indonesia http://duniaengineering.mekarraya.com/?cat=99

5 de 21 02/06/2011 01:48 p.m.

Page 6: Allen Bradley Micrologix 1100 Ethernet Configuration

In the lower half of the screen you will now see your device added to the “Relation List”5.

Rockwell PLC : Blog Dunia Engineering Indonesia http://duniaengineering.mekarraya.com/?cat=99

6 de 21 02/06/2011 01:48 p.m.

Page 7: Allen Bradley Micrologix 1100 Ethernet Configuration

Within a few seconds you will see your device request an IP Address again only this time you will see the IP Address youassigned in the “IP Address Column. You are now ready to configure RsLinx.

6.

Rockwell PLC : Blog Dunia Engineering Indonesia http://duniaengineering.mekarraya.com/?cat=99

7 de 21 02/06/2011 01:48 p.m.

Page 8: Allen Bradley Micrologix 1100 Ethernet Configuration

Note that this is only a temporary assignment of the IP Address and you still must assign the device a permanent IP Address.You may now close the BootP Server. I would not worry about saving your changes on the BootP Server as these settingwere temporary just to set the IP Address so that you can connect to the device with RsLinx

7.

Now that we have initially set the IP Address using one of the above methods we are ready to configure RsLinx to connect to the device.First let’s open RsLinx. This program is already running as a service and all you need to do is find the RsLinx icon in the bottom righthand corner and click on it

There are two drivers that can be used in RsLinx to connect to the device

Ethernet/IP Driver – This driver is by far the easiest to use because it requires no configuration. Each device broadcast informationacross the Ethernet network with RsLinx uses to discover device. The downside to this method is depending on your network setupFirewalls and VPN configurations may block these broadcast. If you can’t see your device using this method use the Ethernet

1.

Rockwell PLC : Blog Dunia Engineering Indonesia http://duniaengineering.mekarraya.com/?cat=99

8 de 21 02/06/2011 01:48 p.m.

Page 9: Allen Bradley Micrologix 1100 Ethernet Configuration

Driver described in method 2First let’s see if you already have an Ethernet/IP driver configured1.From you menu at the top of RsLinx go to Communications > RsWho. Look at the pane to the left and look for a driversaying “ETHIP-1.” If you see this driver then you are all set, go to step e. If not proceed to step c

2.

From your menu at the top of RsLinx go to Communications > Configure Drivers…3.

Rockwell PLC : Blog Dunia Engineering Indonesia http://duniaengineering.mekarraya.com/?cat=99

9 de 21 02/06/2011 01:48 p.m.

Page 10: Allen Bradley Micrologix 1100 Ethernet Configuration

Under “Available Drive Type” select “Ethernet/IP Driver” and click “Add New.” The default name for the device is“ETHIP-1.” If you wish to change it you may do so now and click “OK.” Close the “Configure Drivers” dialog

4.

From you menu at the top of RsLinx go to Communications > RsWho. Look at the pane to the left, find your5.

Rockwell PLC : Blog Dunia Engineering Indonesia http://duniaengineering.mekarraya.com/?cat=99

10 de 21 02/06/2011 01:48 p.m.

Page 11: Allen Bradley Micrologix 1100 Ethernet Configuration

“ETHIP-1” driver, and select it. In a few moments you should now see your device in the right pane.

If you do not see the device, verify that you have followed the previous steps. If you have then try the EthernetDriver below as you may have something on the network blocking the request.

6.

Ethernet Driver – This driver is not plug and play like the Ethernet/IP driver. You must configure the IP Addresses you wishRsLinx to look for devices on.

2.

From your menu at the top of RsLinx go to Communications > Configure Drivers…1.

Rockwell PLC : Blog Dunia Engineering Indonesia http://duniaengineering.mekarraya.com/?cat=99

11 de 21 02/06/2011 01:48 p.m.

Page 12: Allen Bradley Micrologix 1100 Ethernet Configuration

Under “Available Drive Type” select “Ethernet Devices” and click “Add New.” The default name for the device is“AB_ETH-1.” If you wish to change it you may do so now and click “OK.”

2.

Rockwell PLC : Blog Dunia Engineering Indonesia http://duniaengineering.mekarraya.com/?cat=99

12 de 21 02/06/2011 01:48 p.m.

Page 13: Allen Bradley Micrologix 1100 Ethernet Configuration

Now you will see the “Station Mapping dialog come up3.

Enter the IP Address of your device and click “OK”4.

Rockwell PLC : Blog Dunia Engineering Indonesia http://duniaengineering.mekarraya.com/?cat=99

13 de 21 02/06/2011 01:48 p.m.

Page 14: Allen Bradley Micrologix 1100 Ethernet Configuration

From you menu at the top of RsLinx go to Communications > RsWho. Look at the pane to the left, find your“ABETH-1” driver, and select it. In a few moments you should now see your device in the right pane.

5.

Rockwell PLC : Blog Dunia Engineering Indonesia http://duniaengineering.mekarraya.com/?cat=99

14 de 21 02/06/2011 01:48 p.m.

Page 15: Allen Bradley Micrologix 1100 Ethernet Configuration

All that is left now is to set your communications path in RsLogix 500.3.From the top menu of RsLogix 500 go to Comms > System Comms.1.

Rockwell PLC : Blog Dunia Engineering Indonesia http://duniaengineering.mekarraya.com/?cat=99

15 de 21 02/06/2011 01:48 p.m.

Page 16: Allen Bradley Micrologix 1100 Ethernet Configuration

Select the Ethernet driver in the left pane that you chose to configure in step 2 and click on your devicein the right pane

2.

Rockwell PLC : Blog Dunia Engineering Indonesia http://duniaengineering.mekarraya.com/?cat=99

16 de 21 02/06/2011 01:48 p.m.

Page 17: Allen Bradley Micrologix 1100 Ethernet Configuration

From here select OK and you are ready to go. Also you may select “Online” instead of OK toimmediately go online or “Upload” to upload the image out of the processor

3.

Now you are online with your device but we may not have permanently set the IP Address. You may do thisby either setting the IP Address in your offline file and then downloading it or you may set it while onlinewith the processor. The steps are the same. The only difference is if you do it with your offline file then don’tforget to download it.

4.

Open your file in RsLogix 5001.On the left pane go to Project > Controller and double click Channel Configuration.2.

Rockwell PLC : Blog Dunia Engineering Indonesia http://duniaengineering.mekarraya.com/?cat=99

17 de 21 02/06/2011 01:48 p.m.

Page 18: Allen Bradley Micrologix 1100 Ethernet Configuration

Select the Channel 1 tab and configure the IP Address, Subnet and Gateway. Uncheck the “BOOTPEnable” and click Ok. Your IP Address is now permanently set

3.

Rockwell PLC : Blog Dunia Engineering Indonesia http://duniaengineering.mekarraya.com/?cat=99

18 de 21 02/06/2011 01:48 p.m.

Page 19: Allen Bradley Micrologix 1100 Ethernet Configuration

Article written by TWControls

Start Slide Show with PicLens Lite

Filed under Allen Bradlley, Rockwell PLC · Tagged with

Quick Search

Rockwell PLC : Blog Dunia Engineering Indonesia http://duniaengineering.mekarraya.com/?cat=99

19 de 21 02/06/2011 01:48 p.m.

Page 20: Allen Bradley Micrologix 1100 Ethernet Configuration

Recent Posts

Scaffolding In Tissue EngineeringThe Engineering Handbook 2nd Edition (Repost)3 Engineering Books FreeAirbus Series Vol.1 Deluxe EditionA First Course in digital communications

Archives

October 2009September 2009August 2009July 2009June 2009April 2009March 2009February 2009January 2009December 2008November 2008October 2008July 2008June 2008April 2008August 2007

Links

Development BlogDocumentationPluginsSuggest IdeasSupport ForumThemes

Rockwell PLC : Blog Dunia Engineering Indonesia http://duniaengineering.mekarraya.com/?cat=99