AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit,...
Transcript of AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit,...
![Page 1: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications](https://reader035.fdocuments.in/reader035/viewer/2022071010/5fc8060385ba707b7314b522/html5/thumbnails/1.jpg)
AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview
DRaaS
AllConnected Veeam Solutions Overview
Document Type
Sales and Marketing
![Page 2: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications](https://reader035.fdocuments.in/reader035/viewer/2022071010/5fc8060385ba707b7314b522/html5/thumbnails/2.jpg)
AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview
VEEAM OVERVIEW
AllConnected leverages Veeam technology to offer a number of options to protect critical
applications and systems.
Cloud Connect Replication: SSL based Replication using Veeam’s Cloud Connect technology is
our primary offering.
VPN Based Replication: Depending on the complexity and unique business needs of each client,
AllConnected can develop solutions surrounding traditional VPNs.
![Page 3: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications](https://reader035.fdocuments.in/reader035/viewer/2022071010/5fc8060385ba707b7314b522/html5/thumbnails/3.jpg)
AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview
1. Offsite Replication using Veeam Cloud Connect
a. Imaged Based VM Replication
b. Service Provider Model – SP provides resources (Compute and Storage)
c. Partial Site Failover ability with built-in Network Extension Appliance
d. Only need one Public IP
e. Built in WAN Acceleration available
f. Straightforward setup to connect to Service Provider
![Page 4: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications](https://reader035.fdocuments.in/reader035/viewer/2022071010/5fc8060385ba707b7314b522/html5/thumbnails/4.jpg)
AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview
2. Offsite Replication using traditional VPN
a. Imaged Based Replication
b. Service Provider Model – SP provides resources (Compute and Storage)
c. Ability to design network architecture and recovery environment to address larger organizations with complex
network requirements, including various firewall requirements
d. Ability to develop partial and full site failover plans in collaboration with the client
AllConnected VMware ESX
Client
Replica
DataStore
AllConnected VM Infrastructure
Veeam Role: Veeam Proxy
Server Type: VM
Veeam Role: Veeam Proxy
Server Type: VM
Veeam Roles for Replication
SAN
Client VM Infrastructure
VMware ESX
VPN
Veeam Roles for Local Backups and Replication
Veeam Role: Veeam ProxyVeeam Role: Veeam Proxy
+ Bkp RepoVeeam Role: Veeam Proxy
+ Bkp Repo
Veeam Role: Veeam VBR
Server Type: VM
Veeam Backup and
Replication Server
![Page 5: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications](https://reader035.fdocuments.in/reader035/viewer/2022071010/5fc8060385ba707b7314b522/html5/thumbnails/5.jpg)
AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview
3. Veeam Features Demo
Partial Veeam Cloudconnect Failover using VM replicas
Scenario: Server Failure at primary site. Failover to recovery environment.
Recovery Environment: Off site data center.
Demo: VM is spun up in offsite data center. Access to VM and data verified.
![Page 6: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications](https://reader035.fdocuments.in/reader035/viewer/2022071010/5fc8060385ba707b7314b522/html5/thumbnails/6.jpg)
AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview
WHY ALLCONNECTED?
1. Failover Planning and Development
An important question to ask is: Do you know for sure that your failover solution will work during an
actual disaster event?
Although many Service Providers offer cloud resources to backup and replicate VMs, they often
leave the failover planning and testing up to the client.
At AllConnected our objective is to collaborate with each client to develop a tested and
validated failover solution.
Various levels of Failover Planning and Development services are available depending on each
organization’s requirements. For example, some client’s look to us for a partial failover solution whereas others engage us to develop a full site failover plan.
![Page 7: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications](https://reader035.fdocuments.in/reader035/viewer/2022071010/5fc8060385ba707b7314b522/html5/thumbnails/7.jpg)
AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview
Figure 1a – Portion of Sample Failover Test Plan
Task ID Task ExecutorScheduled Date &
TimeTask Description Status
Est.Duratio
n
PRE-01Failover Planning: Complete Failover Specifications. Verify VMs to
be included in Test. Boot Order. Priorities. Network Configs.Completed 2 Hrs
PRE-02Veeam Failover Plan: Ensure Veeam Failover Plans are configured
per Failover SpecificationsCompleted 1 hr
PRE-03Network Configs: Ensure Public IP Assignments; Port Fowarding
Rules; VLAN configsCompleted 1 hr
PRE-04 DNS: Update DNS to map new Public IPS Completed 30 min
PRE-05 Pre-Test: VM Failover Tests and Verification Completed 1 hr
PRE-06Pre Test: Perform Operational Health Checks :(Network, VMWare,
SAN, etc.)Completed 30 min
PRE-07 Pre-Test: Replication Check. Ensure all jobs are healthy Completed 30 min
Task ID Task ExecutorScheduled Date &
TimeTask Description Status
Est.Duratio
n
FOT-01Pre-Failover Task: Pause Replication for VMs in [Client] Failover
PlanScheduled 10 min
FOT-02 Join Failover Test Webex Conference Scheduled 5 min
FOT-03 Execute Veeam Failover Plan: [Client] Failover Plan Scheduled 15 min
FOT-04 Verify VMs in [Client] Failover Plan are Online and accessible Scheduled 5 min
FOT-05 Hand off VMs to [Client] for Application Checks Scheduled 5 min
FOT-06Application Checks: Perform Application Checks, Run
Infrastructure Setup Tasks, Verify Application FunctionalityScheduled 1 Hour
FOT-07Documentation: Document Steps, Record Results, Identify
requirements for future Test PlanScheduled 1 Hour
AllConnected DRaaS Failover Test PlanClient:
Test Date and Time:
Conference:
PHASE: PRE-FAILOVER TASKS
PHASE: FAILOVER TEST
![Page 8: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications](https://reader035.fdocuments.in/reader035/viewer/2022071010/5fc8060385ba707b7314b522/html5/thumbnails/8.jpg)
AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview
2. Commitment to quality from beginning to end
AllConnected’s commitment to quality starts during the assessment process, then throughout the
development of a DRaaS Solution, on to Onboarding and throughout the day to day Operations.
OnboardingAssessment Solution Proposal Operational Excellence
![Page 9: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications](https://reader035.fdocuments.in/reader035/viewer/2022071010/5fc8060385ba707b7314b522/html5/thumbnails/9.jpg)
AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview
Assessment Process: Quality starts with the initial discovery and assessment process where we seek to
gather accurate information about each of our clients to determine their unique business needs .We
believe that a quality assessment will result in a quality solution.
We evaluate key data and metrics to develop our DRaaS solution:
o RPO/RTO requirements
o VM, Storage and Compute requirements
o Partial vs Full Site Failover requirements
o Network and Remote Access Architecture
o Types of Application and Systems that require protection
Figure 2a – Portion of Assessment Worksheet
1.60
Client Name:
Site Name:
# of Servers # of VMs Memory CPU
Storage Total
Allocated
(in GB)
Storage
Current
Utilization
(in GB)
TOTALS 1 1 TOTALS 8 4 0 125
VM Host NameBusiness Function / Application
Role
VM, HyperV
VMWare
Version
(Needs to be
4.x or higher)
OS Server
Role (IIS,
SQL, File,
App)
OS and VersionMemory
(In GB)
CPU
(Specs and
Quantity)
Total Server Data
Size in GB
Current Storage
Utilzation (GB)
General VM Info VM Resources
DRaaS - Assessment Worksheet
VM Inventory
Version:
![Page 10: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications](https://reader035.fdocuments.in/reader035/viewer/2022071010/5fc8060385ba707b7314b522/html5/thumbnails/10.jpg)
AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview
Solution Proposal: After gathering the necessary data during the assessment phase, a solution is
developed for each client based on their unique needs. RPO, RTO, Application protection
requirements, remote access methods, and storage and network configurations are all taken into
account when designing the solution.
Figure 2b – Example DRaaS Design
AllConnected VMware ESX
Client
Replica
DataStore
AllConnected VM Infrastructure
Hostname:
IP:
Role: Veeam Proxy
Server Type: VM
Hostname:
IP:
Role: Veeam Proxy
Server Type: VM
CloudConnect Veeam Roles for Replication
SAN
VM Infrastructure
VMware ESX
CloudConnect
AllConnected, Inc.
DRaaS – Infrastructure Design
Veeam Roles for Replication
Hostname:
IP:
Role: Veeam VBR
Server Type: VM
Simple Deployment:
Handles Proxy and Repository Roles
Hostname:
IP:
Role: Veeam VBR
Server Type: VM
![Page 11: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications](https://reader035.fdocuments.in/reader035/viewer/2022071010/5fc8060385ba707b7314b522/html5/thumbnails/11.jpg)
AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview
Onboarding Process: After the Proposal Solution has been signed, the Onboarding process promptly
begins. Quality assurance processes are followed to ensure each onboarding effort consistently
delivers on the developed solution.
Figure 2c – Onboarding Workflow
Onboarding Preliminary
Tasks
Appliance Provisioning and
Installation
Backup and Replication
Configuration
NOC Operations Hand Off /
Failover Test Scheduling
Figure 2d – Portion of Onboarding QA Checklist
Client Setup and Job Configurations
Perform Veeam Tenant Creation
Perform Veeam Hardware Plan Setup including NEA Config (Setup VM on
Client Infrastructure)
Perform Veeam Failov er Plan Setup
Perform Veeam Off Site Replication Job Setup
Perform Veeam On Prem Backup Job Setup (if Applicable)
Test Backup Jobs using temporary Replication Backup Sets
Perform Initial Monitoring of Replication Jobs and Ensure Successful
Replication
Update VM Master Sheet with updated Job Configuration Info (Job Names,
RPOs, etc.)
![Page 12: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications](https://reader035.fdocuments.in/reader035/viewer/2022071010/5fc8060385ba707b7314b522/html5/thumbnails/12.jpg)
AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview
Operational Excellence: Replication Management. NOC Monitoring and Alerts. Job Scheduling.
RPO Management. Veeam Infrastructure Updates and Optimizations. Documentation. Incident and
Problem Management.
Those are just some of things you don’t have to worry about since AllConnected has all of that covered as part of the DRaaS offering.
Figure 2e – AllConnected Service Management Functions
Backup and Replication
Management
Change and
Configuration
Management
Incident and Problem
Management
Capacity Management
Updates and Patch
Management
![Page 13: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications](https://reader035.fdocuments.in/reader035/viewer/2022071010/5fc8060385ba707b7314b522/html5/thumbnails/13.jpg)
AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview
Infrastructure Management:
o Premium Nimble SAN Storage
o Cisco UCS Compute
o Secure SAS Data Center (SAS 70 Type II and SSAE 16 SOC I complaint)
Figure 2f – Example “POD” Setup (AllConnected’s Modular/Scalable Compute and Storage Units)
FAN STATUS
FAN STATUS
FAN STATUS
FAN STATUS
FAN STATUS
FAN STATUS
FAN STATUS
FAN STATUS
CHS A56
FAN 1 FAN 5 FAN 2 FAN 6 FAN 3 FAN 7 FAN 4 FAN 8
!
FA
UL
T
RE
MO
VE
PO
WE
R
FA
UL
T
RE
MO
VE
PO
WE
R
Controller
Power supply A
100 – 240 VAC11.5 – 5.5 A50 – 60 Hz
For fully-loaded productMaximum Input power settings
Model CS460GPower supply B
Controller
Unit is powered by dual power
cords. To disconnect the unit,
remove both power cords.
tg 1 tg 2
eth2
eth1/m
Heavy 34.5 kg (75.9)
POD Design
POD Type : VMware
Compute Specifications
Manufacturer: Cisco
Model: UCS B200 M4 (QTY x 4 Blades)
CPU: 96 Cores (192 Threads)
Memory: 2 TB
Storage Specifications
Manufacturer: Nimble
Model: CS 1000
Capacity: 59 TB Useable (No
Compression)