AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit,...

13
AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview DRaaS AllConnected Veeam Solutions Overview Document Type Sales and Marketing

Transcript of AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit,...

Page 1: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications

AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview

DRaaS

AllConnected Veeam Solutions Overview

Document Type

Sales and Marketing

Page 2: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications

AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview

VEEAM OVERVIEW

AllConnected leverages Veeam technology to offer a number of options to protect critical

applications and systems.

Cloud Connect Replication: SSL based Replication using Veeam’s Cloud Connect technology is

our primary offering.

VPN Based Replication: Depending on the complexity and unique business needs of each client,

AllConnected can develop solutions surrounding traditional VPNs.

Page 3: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications

AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview

1. Offsite Replication using Veeam Cloud Connect

a. Imaged Based VM Replication

b. Service Provider Model – SP provides resources (Compute and Storage)

c. Partial Site Failover ability with built-in Network Extension Appliance

d. Only need one Public IP

e. Built in WAN Acceleration available

f. Straightforward setup to connect to Service Provider

Page 4: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications

AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview

2. Offsite Replication using traditional VPN

a. Imaged Based Replication

b. Service Provider Model – SP provides resources (Compute and Storage)

c. Ability to design network architecture and recovery environment to address larger organizations with complex

network requirements, including various firewall requirements

d. Ability to develop partial and full site failover plans in collaboration with the client

AllConnected VMware ESX

Client

Replica

DataStore

AllConnected VM Infrastructure

Veeam Role: Veeam Proxy

Server Type: VM

Veeam Role: Veeam Proxy

Server Type: VM

Veeam Roles for Replication

SAN

Client VM Infrastructure

VMware ESX

VPN

Veeam Roles for Local Backups and Replication

Veeam Role: Veeam ProxyVeeam Role: Veeam Proxy

+ Bkp RepoVeeam Role: Veeam Proxy

+ Bkp Repo

Veeam Role: Veeam VBR

Server Type: VM

Veeam Backup and

Replication Server

Page 5: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications

AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview

3. Veeam Features Demo

Partial Veeam Cloudconnect Failover using VM replicas

Scenario: Server Failure at primary site. Failover to recovery environment.

Recovery Environment: Off site data center.

Demo: VM is spun up in offsite data center. Access to VM and data verified.

Page 6: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications

AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview

WHY ALLCONNECTED?

1. Failover Planning and Development

An important question to ask is: Do you know for sure that your failover solution will work during an

actual disaster event?

Although many Service Providers offer cloud resources to backup and replicate VMs, they often

leave the failover planning and testing up to the client.

At AllConnected our objective is to collaborate with each client to develop a tested and

validated failover solution.

Various levels of Failover Planning and Development services are available depending on each

organization’s requirements. For example, some client’s look to us for a partial failover solution whereas others engage us to develop a full site failover plan.

Page 7: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications

AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview

Figure 1a – Portion of Sample Failover Test Plan

Task ID Task ExecutorScheduled Date &

TimeTask Description Status

Est.Duratio

n

PRE-01Failover Planning: Complete Failover Specifications. Verify VMs to

be included in Test. Boot Order. Priorities. Network Configs.Completed 2 Hrs

PRE-02Veeam Failover Plan: Ensure Veeam Failover Plans are configured

per Failover SpecificationsCompleted 1 hr

PRE-03Network Configs: Ensure Public IP Assignments; Port Fowarding

Rules; VLAN configsCompleted 1 hr

PRE-04 DNS: Update DNS to map new Public IPS Completed 30 min

PRE-05 Pre-Test: VM Failover Tests and Verification Completed 1 hr

PRE-06Pre Test: Perform Operational Health Checks :(Network, VMWare,

SAN, etc.)Completed 30 min

PRE-07 Pre-Test: Replication Check. Ensure all jobs are healthy Completed 30 min

Task ID Task ExecutorScheduled Date &

TimeTask Description Status

Est.Duratio

n

FOT-01Pre-Failover Task: Pause Replication for VMs in [Client] Failover

PlanScheduled 10 min

FOT-02 Join Failover Test Webex Conference Scheduled 5 min

FOT-03 Execute Veeam Failover Plan: [Client] Failover Plan Scheduled 15 min

FOT-04 Verify VMs in [Client] Failover Plan are Online and accessible Scheduled 5 min

FOT-05 Hand off VMs to [Client] for Application Checks Scheduled 5 min

FOT-06Application Checks: Perform Application Checks, Run

Infrastructure Setup Tasks, Verify Application FunctionalityScheduled 1 Hour

FOT-07Documentation: Document Steps, Record Results, Identify

requirements for future Test PlanScheduled 1 Hour

AllConnected DRaaS Failover Test PlanClient:

Test Date and Time:

Conference:

PHASE: PRE-FAILOVER TASKS

PHASE: FAILOVER TEST

Page 8: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications

AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview

2. Commitment to quality from beginning to end

AllConnected’s commitment to quality starts during the assessment process, then throughout the

development of a DRaaS Solution, on to Onboarding and throughout the day to day Operations.

OnboardingAssessment Solution Proposal Operational Excellence

Page 9: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications

AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview

Assessment Process: Quality starts with the initial discovery and assessment process where we seek to

gather accurate information about each of our clients to determine their unique business needs .We

believe that a quality assessment will result in a quality solution.

We evaluate key data and metrics to develop our DRaaS solution:

o RPO/RTO requirements

o VM, Storage and Compute requirements

o Partial vs Full Site Failover requirements

o Network and Remote Access Architecture

o Types of Application and Systems that require protection

Figure 2a – Portion of Assessment Worksheet

1.60

Client Name:

Site Name:

# of Servers # of VMs Memory CPU

Storage Total

Allocated

(in GB)

Storage

Current

Utilization

(in GB)

TOTALS 1 1 TOTALS 8 4 0 125

VM Host NameBusiness Function / Application

Role

VM, HyperV

VMWare

Version

(Needs to be

4.x or higher)

OS Server

Role (IIS,

SQL, File,

App)

OS and VersionMemory

(In GB)

CPU

(Specs and

Quantity)

Total Server Data

Size in GB

Current Storage

Utilzation (GB)

General VM Info VM Resources

DRaaS - Assessment Worksheet

VM Inventory

Version:

Page 10: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications

AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview

Solution Proposal: After gathering the necessary data during the assessment phase, a solution is

developed for each client based on their unique needs. RPO, RTO, Application protection

requirements, remote access methods, and storage and network configurations are all taken into

account when designing the solution.

Figure 2b – Example DRaaS Design

AllConnected VMware ESX

Client

Replica

DataStore

AllConnected VM Infrastructure

Hostname:

IP:

Role: Veeam Proxy

Server Type: VM

Hostname:

IP:

Role: Veeam Proxy

Server Type: VM

CloudConnect Veeam Roles for Replication

SAN

VM Infrastructure

VMware ESX

CloudConnect

AllConnected, Inc.

DRaaS – Infrastructure Design

Veeam Roles for Replication

Hostname:

IP:

Role: Veeam VBR

Server Type: VM

Simple Deployment:

Handles Proxy and Repository Roles

Hostname:

IP:

Role: Veeam VBR

Server Type: VM

Page 11: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications

AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview

Onboarding Process: After the Proposal Solution has been signed, the Onboarding process promptly

begins. Quality assurance processes are followed to ensure each onboarding effort consistently

delivers on the developed solution.

Figure 2c – Onboarding Workflow

Onboarding Preliminary

Tasks

Appliance Provisioning and

Installation

Backup and Replication

Configuration

NOC Operations Hand Off /

Failover Test Scheduling

Figure 2d – Portion of Onboarding QA Checklist

Client Setup and Job Configurations

Perform Veeam Tenant Creation

Perform Veeam Hardware Plan Setup including NEA Config (Setup VM on

Client Infrastructure)

Perform Veeam Failov er Plan Setup

Perform Veeam Off Site Replication Job Setup

Perform Veeam On Prem Backup Job Setup (if Applicable)

Test Backup Jobs using temporary Replication Backup Sets

Perform Initial Monitoring of Replication Jobs and Ensure Successful

Replication

Update VM Master Sheet with updated Job Configuration Info (Job Names,

RPOs, etc.)

Page 12: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications

AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview

Operational Excellence: Replication Management. NOC Monitoring and Alerts. Job Scheduling.

RPO Management. Veeam Infrastructure Updates and Optimizations. Documentation. Incident and

Problem Management.

Those are just some of things you don’t have to worry about since AllConnected has all of that covered as part of the DRaaS offering.

Figure 2e – AllConnected Service Management Functions

Backup and Replication

Management

Change and

Configuration

Management

Incident and Problem

Management

Capacity Management

Updates and Patch

Management

Page 13: AllConnected Veeam Solutions OverviewUnit is powered by dual power cords. To disconnect the unit, power cords. tg 1 tg 2 eth2 eth1/m 9) POD Design POD Type : VMware Compute Specifications

AllConnected | 4514 Ish Drive, Suite 103 | Simi Valley, CA 93063 AllConnected Veeam Solutions Overview

Infrastructure Management:

o Premium Nimble SAN Storage

o Cisco UCS Compute

o Secure SAS Data Center (SAS 70 Type II and SSAE 16 SOC I complaint)

Figure 2f – Example “POD” Setup (AllConnected’s Modular/Scalable Compute and Storage Units)

FAN STATUS

FAN STATUS

FAN STATUS

FAN STATUS

FAN STATUS

FAN STATUS

FAN STATUS

FAN STATUS

CHS A56

FAN 1 FAN 5 FAN 2 FAN 6 FAN 3 FAN 7 FAN 4 FAN 8

!

FA

UL

T

RE

MO

VE

PO

WE

R

FA

UL

T

RE

MO

VE

PO

WE

R

Controller

Power supply A

100 – 240 VAC11.5 – 5.5 A50 – 60 Hz

For fully-loaded productMaximum Input power settings

Model CS460GPower supply B

Controller

Unit is powered by dual power

cords. To disconnect the unit,

remove both power cords.

tg 1 tg 2

eth2

eth1/m

Heavy 34.5 kg (75.9)

POD Design

POD Type : VMware

Compute Specifications

Manufacturer: Cisco

Model: UCS B200 M4 (QTY x 4 Blades)

CPU: 96 Cores (192 Threads)

Memory: 2 TB

Storage Specifications

Manufacturer: Nimble

Model: CS 1000

Capacity: 59 TB Useable (No