Agenda
• MP2 Vs X2 – the difference• How to order
–What is Included–Core features Vs Options
• Mountings & Accessories• Printing Solutions • Respironics CO2
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 2
CONFIDENTIAL 3Division, Author, MMMM dd, yyyy, Reference
IntelliVue FamilyIntelliVue Family
CONFIDENTIAL 4Division, Author, MMMM dd, yyyy, Reference
MP2 / X2 – IntelliVue Family
MP2MP2 X2X2
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 3
CONFIDENTIAL 5Division, Author, MMMM dd, yyyy, Reference
Intended UseIntended Use
CONFIDENTIAL 6Division, Author, MMMM dd, yyyy, Reference
MP2 – Low End Monitor
• Standalone patient monitor
M8102AM8102A
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 4
CONFIDENTIAL 7Division, Author, MMMM dd, yyyy, Reference
X2 – New MMS Generation• Processing unit and display in a single package• Can be used as an MMS or as a standalone patient monitor
M3002AM3002A
CONFIDENTIAL 8Division, Author, MMMM dd, yyyy, Reference
FeaturesFeatures
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 5
CONFIDENTIAL 9Division, Author, MMMM dd, yyyy, Reference
X2 – MP2
3,5’’color TFT-
displaywith Touch
188 x 99 x 86 mm7.4 x 3.9 x 3.4 in
1.2 kg (2.7 lbs)
CONFIDENTIAL 10Division, Author, MMMM dd, yyyy, Reference
X2 – MP2
You can usea pen
to operatethe screen
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 6
CONFIDENTIAL 11Division, Author, MMMM dd, yyyy, Reference
X2 – MP2
Rugged design
1 meter drop test
INTERNAL USE ONLY 12PMD, Martin Allgeier, Fall 2007
X2 – MP2 Profile Outdoor*
X2/MP2 onlyX2/MP2 only
VolumeWhite Colors
*Screenshots in Demo Mode
• For use in typical outdoor conditions
– bright sunlight– higher ambient
noise
Brightness
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 7
INTERNAL USE ONLY 13PMD, Martin Allgeier, Fall 2007
Green FlagshipGreen Flagship
INTERNAL USE ONLY PMD, Martin Allgeier, Fall 2007
EcoDesign Summary Patient Monitor MP2/X2
Guess what progress...!
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 8
INTERNAL USE ONLY PMD, Martin Allgeier, Fall 2007
Improvements MP2 vs. M3Actual Target
• Weight: 1.2 kg vs. 2.65 kg 1) - 55% - 30% 2)
• Energy: 4.5 W vs. 12.5 W 1) - 64% - 50% 2)
• Packaging: 1.1 kg vs. 1.58 kg - 30% - 25%
• Hazardous materials: no BeCu contact springs used
EcoDesign Summary Patient Monitor MP2/X2
The 1st PMS Product to carry this Logo!
INTERNAL USE ONLY 16PMD, Martin Allgeier, Fall 2007
X2 versus MP2X2 versus MP2
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 9
INTERNAL USE ONLY 17PMD, Martin Allgeier, Fall 2007
X2 versus MP2
1.5 kg (3.3 lbs)Weight
StandardTouch screen
3.5"TFT QVGA (320 x 240 pixels)Display
MP2X2Options Features
16 P, 4h@12s, 24h@1min, 48h@5min(no extended database)Trend
StandardTabular and Graphic Trend
3 WavesWaveforms
INTERNAL USE ONLY 18PMD, Martin Allgeier, Fall 2007
X2 versus MP2
n/aMasimo®Optional SpO2 Algorithm
StandardConnectivity to Extensions
Respironics ® mainstream/sidestreamCO2 Technology
(IBP+Temp) or CO2Optional Measurement
ECG - SpO2 - NBPBasic Measurement
MP2X2Options Features
Optional
OptionalStandardST Map
StandardECG Sync Pulse Output
OptionalConventional 12 lead
StandardEASI 12 lead
StandardFull Arrythmia
StandardBasic Arrythmia
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 10
INTERNAL USE ONLY 19PMD, Martin Allgeier, Fall 2007
X2 versus MP2
n/aStandardCompanion Mode
Via PC or PIICReports
OptionalITS Network (Smart Hopping) 1.4/2.4 GHz
OptionalStandardNetwork to PIIC
StandardNetwork to PC
MP2X2Options Features
StandardMMS mount
StandardAnti-slip Pad
3 hrsBattery Life
StandardBattery
StandardOptionalPower Supply with Network
StandardOptionalHandle
INTERNAL USE ONLY 20PMD, Martin Allgeier, Fall 2007
MeasurementsMeasurements
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 11
INTERNAL USE ONLY 21PMD, Martin Allgeier, Fall 2007
X2 – MP2 Measurements
Standard1. ECG/Resp2. SpO2 FAST– X2:
• FAST or• Masimo ®
3. NBP
Optional4. Temp 5. IBP
OR6. CO2 X2 MP2
INTERNAL USE ONLY 22PMD, Martin Allgeier, Fall 2007
X2 Measurement OptionsStandard
ECG/RespSpO2 FAST
• FAST #A01• Masimo® #A03
NBP
Optional Temp/IBP #C06
Temp AND IBP
OR
#C14CO2 Ready
X2
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 12
INTERNAL USE ONLY 23PMD, Martin Allgeier, Fall 2007
MP2 Measurement Options
Standard #B20ECG/RespSpO2 FASTNBP
Optional Temp/IBP #B22
Temp AND IBP
OR #B23CO2 ready MP2
INTERNAL USE ONLY 24PMD, Martin Allgeier, Fall 2007
X2 – MP2 Measurements Flexibility• Hemodynamic Extension• Capnography Extension
Extensions are NOT operable without power from monitor or power supplyM3012A
M3015A
M3014A
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 13
INTERNAL USE ONLY 25PMD, Martin Allgeier, Fall 2007
X2 – MP2 Measurement Selection Window
• New look• Unavailable measurements grayed-out• Measurement conflicts displayed in red
INTERNAL USE ONLY 26PMD, Martin Allgeier, Fall 2007
X2 – MP2 Clinical applications - Options
X2 MP2
StandardST segment analysis
StandardEASI 12 leadStandard5-/6-lead ECG
#C15StandardFull NetworkingStandard (but without ECG Sync Cable #SN3)ECG Sync Pulse Output
#C13StandardST Map
#C01
#C12 (as a hardware option)Conventional 12 leadStandardFull Arrythmia
StandardBasic Arrythmia
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 14
INTERNAL USE ONLY PMD, Martin Allgeier, Fall 2007
MP2 Hardware - Standard
• All MP2 monitors will come with –1 Handle–1 Anti-Slip Pad–1 Power and Network Adapter–1 SRL Cable–1 Battery with Charge Adapter–Network Hardware (need option C15 to
connect to PIIC)
INTERNAL USE ONLY PMD, Martin Allgeier, Fall 2007
X2 Hardware - Standard
• All MP2 monitors will come with –1 Anti-Slip Pad–1 SRL Cable (you need to order Option
SC? For length)–1 Battery with Charge Adapter–Network Hardware & Software
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 15
INTERNAL USE ONLY 29PMD, Martin Allgeier, Fall 2007
X2 – MP2 Hardware - Options
X2 MP2Standard#E31Carrying handle
#E18Extra 5 Anti-slip pad
INTERNAL USE ONLY 30PMD, Martin Allgeier, Fall 2007
X2 – MP2 Hardware - Options
X2 MP2
Part No. 9898 031 53021 ordirectly from GCX
Roller stand (no optionnumber)
#E20MMS mounting clamp
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 16
INTERNAL USE ONLY 31PMD, Martin Allgeier, Fall 2007
X2 – MP2 Hardware – Future Options
X2 MP2
#E23Protective casing
INTERNAL USE ONLY 32PMD, Martin Allgeier, Fall 2007
X2 – MP2 Hardware – Future Options
X2 MP2
#E19Carrying Strap
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 17
INTERNAL USE ONLY 33PMD, Martin Allgeier, Fall 2007
X2 – MP2 Hardware - Options
X2 MP2
#J47 (ROW)Instrument telemetry 2.4 GHz
Locatiaon tracking via PIIC
Standard#E27Power and network adapter
1 battery #E24 / 2 batteries #26Additional Lithium ion battery
#J45 (US only)Instrument telemetry 1.4 GHz
INTERNAL USE ONLY PMD, Martin Allgeier, Fall 2007
X2 – MP2 Hardware - Reminder
• For X2, battery can be charged by the Host Monitor. Only order Power & Network Adapter if needed to be monitoring outside the Host for extended time (eg X-Ray room)
• Order M8023A If you need extra Power and Network Adapters
• One Battery is included! All batteries will come with Adapter for the Battery Conditioner.
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 18
INTERNAL USE ONLY 35PMD, Martin Allgeier, Fall 2007
ECG Sync Output
ECG Sync Output
INTERNAL USE ONLY 36PMD, Martin Allgeier, Fall 2007
X2 – MP2 ECG Sync Pulse OUT
• Connection to synchronize external medical devices– Defibrillator– CT/MR scanner– Trans esophageal echo– Intra-aortic balloon pump (IABP)…
• Digital output – no analog ECG waveform• Special cable required - M3002-61601• Automatic cable detection
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 19
INTERNAL USE ONLY 37PMD, Martin Allgeier, Fall 2007
X2 – MP2 ECG Sync Pulse OUT
• Sync Pulse specification– Delay from R-wave peak to start of pulse 20 ms maximum
(per AAMI EC13)– Output signal > 2.4 V– Minimum required R-wave amplitude 0.5 mV
Sync Pulse marker
INTERNAL USE ONLY 38PMD, Martin Allgeier, Fall 2007
X2 – MP2 ECG Sync Pulse OUT
• SyncPulse Marker– Choices: On / Off– Default: On– Set to On and plug in the ECG Sync Pulse cable
SyncPulse markers in the ECG wave on the monitor screen
Main Setup > Measurements > ECG
+ =
Measurement Settings
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 20
INTERNAL USE ONLY 39PMD, Martin Allgeier, Fall 2007
digital output
X2 – MP2 ECG Sync Pulse OUT
• ECGOut Size Up/Down– Changes the level of the output signal
for analog output (ECG waveform)– when X2 in companion mode with a
host monitor
Main Setup > Measurements > ECG
analog output
> 2.4 V
INTERNAL USE ONLY 40PMD, Martin Allgeier, Fall 2007
BatteryBattery
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 21
INTERNAL USE ONLY 41PMD, Martin Allgeier, Fall 2007
X2 – MP2 Battery• Battery must always be in X2/MP2, even
when running on AC power• Changing the battery with AC power has
no influence on monitoring– After 15 seconds, severe yellow alarm
– Changing the battery without AC power switches off monitor
– Normal monitor resuming afterwards• Battery minimum 3 hours operating time
INTERNAL USE ONLY 42PMD, Martin Allgeier, Fall 2007
X2 – MP2 Battery LED
Battery recharges automatically when the X2/MP2 is connected to a host monitor or external power supply
Battery or charger malfunctionBattery or charger malfunction
Red flashing intermittently
n/a
Battery charging(off when fully charged)
Connected to monitoror external power supply
Less then 10 minutes power remainingRed flashing
n/aYellow
Running on batteryBattery LED colors
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 22
INTERNAL USE ONLY 43PMD, Martin Allgeier, Fall 2007
X2 – MP2 Battery Charger and Conditioner
• Compatible with Philips Battery Charger and Conditioner M8043A used for batteries of M3/4 MP20/30/40/50
• Adaptor required (included with every battery ordered)
INTERNAL USE ONLY 44PMD, Martin Allgeier, Fall 2007
TrendsTrends
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 23
INTERNAL USE ONLY PMD, Martin Allgeier, Fall 2007
X2 – MP2 Trends
• Both X2 and MP2 can store up to– 48 Hrs @ 5 minute– 24 Hrs @ 1 minute– 4 Hrs @ 12 seconds
• All 3 are being stored in both monitors simultaneously.
• For X2, only 8 Hr of data are uploaded to Receiving Monitor.
Supplies for MMS+
Dave Danehy, Sr. Product ManagerElectrodes, Paper, Fetal, Cardiac Output & AccessoriesMonitoring Supplies2007
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 24
Dave Danehy, August 200747
What about Supplies…? Things to remember!
• Comprehensive portfolio for your customer’s needs– Reusable & Disposable Supplies
• Tools – New Product Reference Table– Literature
Dave Danehy, August 200748
Product Reference Table
Coming so
on!
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 25
Dave Danehy, August 200749
Features and Benefits of MMS+ Supplies
•2 m drop protection provides durability in harsh environments•Meets IEC 60721-3-7/IEC TR 60721-4-7 requirements for vibration, shock and free fall.
Protective Case, 989803153871
• Pad design provides anti slip surface for MMS+ on tables and other flat surfaces.• Pack of 5
Anti Slip Pad, 989803157171
• Durable strap allows for better patient mobility• Integrated cable organizer for better cable management
Carrying Strap, 989803153441
· Provides 3 hrs basic monitoring time for convenient patient transport
Lithium Ion Battery, M4607A
Dave Danehy, August 200750
Tools to help!
• Reference Guide• On Line Store• 800 Number (US only)• Local Supplies Sales Rep• Brochure
– 4522 962 17611/864
NPI Sept 2007 Please contact your local marketing center for latest information
Confidential. For internal use only 26
Dave Danehy, August 200751
Why should you quote?
• Creating a full Philips customer!– Hardware & supplies– Bigger footprint in your account– Creates a loyal customer
• We’re only a phone call away for information and support!