All-Flex Servi-Sert Field Assembled Riser - Honeywell … · All-Flex Servi-Sert® Field Assembled...

2
All-Flex Servi-Sert ® Field Assembled Riser Installation Guide Cut the tubing so the end is square. Wipe the tubing with a clean, dry cloth and inspect the tubing for damage. If there is damage, cut again to remove damaged area. Remove the Servi-Sert service head adapter from the flexible casing. 3 Insert the tubing through the casing. 2 4 1 (continued on opposite side) Mark the stab depth as indicated on the package instructions. Chamfer the OD of the tubing. At the tank 5 6

Transcript of All-Flex Servi-Sert Field Assembled Riser - Honeywell … · All-Flex Servi-Sert® Field Assembled...

All-Flex Servi-Sert® Field Assembled Riser

Installation Guide

Cut the tubing so the end is square.

Wipe the tubing with a clean, dry cloth and inspect the tubing for damage. If there is damage, cut again to remove damaged area.

Remove the Servi-Sert service head adapter from the flexible casing.

3

Insert the tubing through the casing.

2

4

1

(continued on opposite side)

Mark the stab depth as indicated on the package instructions.

Chamfer the OD of the tubing.

At the tank

5 6

Elster Perfection 222 Lake Street Madison, OH 44057USA

T +1 440 428 1171F +1 866 828 6862

www.elster-perfection.com

© 2010 Elster Perfection. All rights reserved.® Registered trademark of Elster Perfection Corporation.

Information contained herein is subject to changewithout notice. Product specifications may change.Contact your Elster Perfection representative for the most current product information. Printed in the United States.

EP-II0003.1-EN-P - June 2010Supercedes EP-II0003-EN-P

About Elster

A world leader in advanced metering infrastructure, integrated metering, and utilization solutions to the gas, electricity and water industries. Elster’s systems and solutions reflect over 170 years of knowledge and experience in measuring precious resources and energy.

Elster provides solutions and advanced technologies to help utilities more easily, efficiently and reliably obtain and use advanced metering intelligence to improve customer service, enhance operational efficiency, and increase revenues. Elster’s AMI solutions enable utilities to cost-effectively generate, deliver, manage, and conserve the life-essential resources of gas, electricity, and water.

Elster has over 7,000 staff and operations in 38 countries in North and South America, Europe, and Asia.

11

9

7

10

8

10

At the tank cont.

At the house

Follow procedures above (steps 1-9) and then...

Connect the Servi-Sert service head adapter to second-stage regulator.

Hook up riser and regulator to house piping.

Stab the tubing into the Servi-Sert service head adapter until the stab depth mark is reached.

Connect the Servi-Sert service head adapter to the flexible casing.

Apply pipe sealant to male threads of Servi-Sert service head adapter.

Utilizing the swivel feature of the All-Flex riser, connect Servi-Sert service head adapter to first-stage regulator and tighten connections.