Alignment and Arthroplasty
description
Transcript of Alignment and Arthroplasty
![Page 1: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/1.jpg)
25 iv 06
Alignment and Arthroplasty
Justin Cobb Johann Henckel, Vijay Kannan, Farhad Iranpour,
Robin Richards
Imperial College London
![Page 2: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/2.jpg)
25 iv 06
Function is what really matters ? The relationship with alignment ? We know that they are related
– But how directly? The rules are different
– For osteotomy• overcorrect 62%
– For uka• Undercorrect leave varus
– For tka• ?undercorrect? or neutral
We also know that everyone is different– So does everyone deserve a unique plan?
![Page 3: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/3.jpg)
25 iv 06
Accuracy vs function
Better function
More accurate surgery
Type II error
![Page 4: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/4.jpg)
25 iv 06
Our Aim
Preop plan for each individual Precise operation Documentation of position achieved Correlated with function
![Page 5: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/5.jpg)
25 iv 06
This paper
Will show you how to measure Will talk about what to measure And suggest a way forward
![Page 6: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/6.jpg)
25 iv 06
1 how to measure
Computerised Axial Tomography– Modality of choice in the skeleton
-Planning
-Outcome measurement
Dose optimisation vs image quality• Minimising dose
![Page 7: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/7.jpg)
25 iv 06
X-rays Inaccurate
– Magnification• 8-20%
– Perspective distortion• Rotation in one plane creates compound errors
![Page 8: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/8.jpg)
25 iv 06
CT
Virtual surgery– Accurate pre-op planning
Ability to measure outcome– And confirm the link
• between structure and function
![Page 9: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/9.jpg)
25 iv 06
Dose measurements Assumed Linear relationship
– between radiation dose and malignancy.
Effective dose mSv-Weighted Dose received by the key dose sensitive organs.
10mSv gives a 1 in 2000 risk of radiation induced malignancy.
2.5mSv is annual background in UK
![Page 10: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/10.jpg)
25 iv 06
Risks CXR – 0.02 mSv Transatlantic flight 0.04mSv Long leg measurement film – 0.7 mSv… Lumbar spine x-ray – 1.3 mSv CT abdo/pelvis – 10mSv
Upper recommended limit – 5 mSv / year
Perth protocol - 2.5 mSv (Chauhan et al JBJS 2004 86 – B) kV 140, mAs 85 2.5mm slices
![Page 11: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/11.jpg)
25 iv 06
Methods
Phantom pelvis and limbs Varied the scan parameters Evaluated the image quality Effective dose measurements 2 commercial software packages
– CT DOSE & CT-EXPO
![Page 12: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/12.jpg)
25 iv 06
Phantom
![Page 13: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/13.jpg)
25 iv 06
Splint
Conventional trauma splint Stabilise leg and knee Distract the medial condyles Blind areas (Movement detection software)
![Page 14: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/14.jpg)
25 iv 06
Splinting
Picture of splint note can open the joint
Motion detecting software
![Page 15: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/15.jpg)
25 iv 06
Hip Centre
![Page 16: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/16.jpg)
25 iv 06
Ankle
![Page 17: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/17.jpg)
25 iv 06
Planning
![Page 18: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/18.jpg)
25 iv 06
Post op analysis
![Page 19: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/19.jpg)
25 iv 06
Post op analysis
![Page 20: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/20.jpg)
25 iv 06
Planned ve achieved
![Page 21: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/21.jpg)
25 iv 06
Tibia
![Page 22: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/22.jpg)
25 iv 06
Results
0.50 0.760.74
Total effective
dose (worst case)
0.0054x2.5mm545120Ankles
0.124x1mm20100120Knees
0.640.370.564x5mm
0.640.370.614x2.5mm580120Hips
Female patientMale patient
Calculation using CT-EXPO programme
Calculation using CT DOSE programme
Effective Dose (mSv)CollimationScan length (cm)
mAskVpArea scanned
![Page 23: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/23.jpg)
25 iv 06
Results
=
~ 0.7mSv ♀ 0.735mSv♂ 0.5mSv
![Page 24: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/24.jpg)
25 iv 06
Scan Time
Actual scan time under 1 Min
![Page 25: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/25.jpg)
25 iv 06
New CT scanners 16/64 slice – 256 More Detectors (Use more of the dose) Artifact reduction Speed Volume data
in 3 planes
Standing CT Segmenting MRI
![Page 26: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/26.jpg)
25 iv 06
Summary 1
How to measure Imperial Protocol: CT can be rapidly acquired 40s 2D and 3D post operative analysis Real measurements of implant position
can be obtained We are now able to fully measure the
accuracy of CAOS systems well within the envelope of +/- 2mm & 2
For the same dose as a standing film
![Page 27: Alignment and Arthroplasty](https://reader035.fdocuments.in/reader035/viewer/2022070418/56815915550346895dc63f8c/html5/thumbnails/27.jpg)
25 iv 06
Our Protocol
451202.5mm5cm distal tib/fib & talus
Ankle
1001201.0mm10cm either side of joint line
Knee
801202.5mmFemoral headHip
80Mid pelvis to feetTopogram(Scout film)
mAskVCollimationAreaPROTOCOL