SPECIFICATION SUBMITTAL Page Job Name: Job Number: Model Numbers: Alena Drapery System System Specification 085319c 1 07.06.15 Alena | Drapery System The AlenaTM Drapery System is an easily installed, low- cost, plug-and-play solution designed for the hospitality and multi-dwelling market. Guests will have two methods of convenient control: via a Lutron or third- party keypad, or by pulling the drapery panel in the direction they want it to move. If a user is unaware of the keypad, they will learn of the drapery’s motorization when they manually pull on the panel, where the drive will take over and move the panel automatically to its Open or Close limit. Features Allows for motorized operation with or without controls Ultra-quiet operation: will not exceed 50 dBA measured 1 m (3 ft) from the Drive Simple plug-and-play installation with no programming required Drapery can be stopped while moving with the touch of any button on a keypad All drives start, move, and stop smoothly and quietly Can be installed in new construction or retrofit application Decouples the EDU and track into two separate components, allowing the EDU to be replaced or upgraded in the field 24 V- low-voltage power 8 year limited warranty Power Operating voltage: Low-voltage 24 V- power supply required Control system power supply offers (spike and brownout) over voltage protection (+/- 10% of line voltage) for all devices in the system. Power supply provides appropriate Electro Static Discharge (ESD) protection for all devices in the system Power must be derived from the Lutron® power supply provided with the drapery system System Capacity Maximum of 1 drive per contact closure output Maximum of 1 drive per power supply AlenaTM Drapery System Performance Uses steel-reinforced high-strength, low-friction belt to reduce noise and drag Supports drapery panels weighing up to 105 pounds (47 kg) Integrates with all third party CCI keypads, switches, and devices Can be controlled from multiple locations (i.e. manually at drape, or via keypad), and allows for operation when power is not available All system components are Electro Static Discharge (ESD) protected • Track length up to 16.4 ft (5 m) Controls The AlenaTM EDU accepts dry contact closure inputs Up to 2 groups of AlenaTM Drives can be controlled with a Two Group Standalone Keypad Up to 2 groups of AlenaTM Drives can be controlled with a QSE-IO Contact Closure Interface Drives can be assigned to different keypad groups by rewiring

Transcript of Alena Drapery System - Lutron Electronics · Alena ™ Drapery System System Specification 085319c...

Page 1: Alena Drapery System - Lutron Electronics · Alena ™ Drapery System System Specification 085319c 1 07.06.15 ... • Pressing any button on a keypad while the drape is moving will

SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Alena™ Drapery System System Specification

085319c 1 07.06.15

Alena™ | Drapery SystemThe AlenaTM Drapery System is an easily installed, low-cost, plug-and-play solution designed for the hospitality and multi-dwelling market. Guests will have two methods of convenient control: via a Lutron or third-party keypad, or by pulling the drapery panel in the direction they want it to move. If a user is unaware of the keypad, they will learn of the drapery’s motorization when they manually pull on the panel, where the drive will take over and move the panel automatically to its Open or Close limit.

Features• Allows for motorized operation with or without controls

• Ultra-quiet operation: will not exceed 50 dBA measured 1 m (3 ft) from the Drive

• Simple plug-and-play installation with no programming required

• Drapery can be stopped while moving with the touch of any button on a keypad

• All drives start, move, and stop smoothly and quietly

• Can be installed in new construction or retrofit application

• Decouples the EDU and track into two separate components, allowing the EDU to be replaced or upgraded in the field

• 24 V- low-voltage power

• 8 year limited warranty

Power• Operating voltage: Low-voltage 24 V- power supply

required

• Control system power supply offers (spike and brownout) over voltage protection (+/- 10% of line voltage) for all devices in the system.

• Power supply provides appropriate Electro Static Discharge (ESD) protection for all devices in the system

• Power must be derived from the Lutron® power supply provided with the drapery system

System Capacity• Maximum of 1 drive per contact closure output

• Maximum of 1 drive per power supply

AlenaTM Drapery System

Performance• Uses steel-reinforced high-strength, low-friction belt to

reduce noise and drag• Supports drapery panels weighing up to 105 pounds (47 kg)• Integrates with all third party CCI keypads, switches, and

devices• Can be controlled from multiple locations (i.e. manually at

drape, or via keypad), and allows for operation when power is not available

• All system components are Electro Static Discharge (ESD) protected

• Track length up to 16.4 ft (5 m)

Controls• The AlenaTM EDU accepts dry contact closure inputs• Up to 2 groups of AlenaTM Drives can be controlled with a

Two Group Standalone Keypad

• Up to 2 groups of AlenaTM Drives can be controlled with a QSE-IO Contact Closure Interface

• Drives can be assigned to different keypad groups by rewiring

Page 2: Alena Drapery System - Lutron Electronics · Alena ™ Drapery System System Specification 085319c 1 07.06.15 ... • Pressing any button on a keypad while the drape is moving will

SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Alena™ Drapery System System Specification

085319c 2 07.06.15

Drapery track options

Center-draw, left-or right-mounted EDU

Left draw/left-mounted EDU

Right draw/right-mounted EDU

NOTE: Valance and drapery not included

Page 3: Alena Drapery System - Lutron Electronics · Alena ™ Drapery System System Specification 085319c 1 07.06.15 ... • Pressing any button on a keypad while the drape is moving will

SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Alena™ Drapery System System Specification

085319c 3 07.06.15

System Capacity

Use this table to determine the maximum pinch pleat drapery panel size the Alena QS drapery system can operate, based upon height and weight.

NOTES• Pinch pleat fullness of 3:1 is allowable for sheer draperies only.

All other draperies must have a fullness of 2.5:1

Alena pinch pleat system capacity

System width Straight track

24 in to 32 in (600 mm to 800 mm) 20 lbs (9 kg)

32 in to 44 in (800 mm to 1100 mm) 30 lbs (13.6 kg)

44 in to 56 in (1100 mm to 1400 mm) 40 lbs (18 kg)

56 in to 68 in (1400 mm to 1700 mm) 55 lbs (24.9 kg)

68 in to 84 in (1700 mm to 2133 mm) 65 lbs (29.5 kg)

84 in to 108 in (2133 mm to 2743 mm) 80 lbs (36.3 kg)

108 in to 132 in (2743 mm to 3353 mm) 105 lbs (47.6 kg)

132 in to 156 in (3353 mm to 3962 mm) 100 lbs (45.3 kg)

156 in to 197 in (3962 mm to 5000 mm) 80 lbs (36.3 kg)

Page 4: Alena Drapery System - Lutron Electronics · Alena ™ Drapery System System Specification 085319c 1 07.06.15 ... • Pressing any button on a keypad while the drape is moving will

SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Alena™ Drapery System System Specification

085319c 4 07.06.15

System dimensions

Top view (single track, right draw)

2.1 in (52.1 mm)1.3 in (31.8 mm)1.6 in (41.3 mm)

3.3 in (83.82 mm)

10.6 in (270 mm)

Front view (single track, right draw)

8.89 in (225.6 mm)

3.3 in (83.8 mm)

2.1 in (52.3 mm)

Electronic Drive Unit1.9 lbs (0.9 kg)

Track width 16.4 ft (5.0 m) max

Page 5: Alena Drapery System - Lutron Electronics · Alena ™ Drapery System System Specification 085319c 1 07.06.15 ... • Pressing any button on a keypad while the drape is moving will

SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Alena™ Drapery System System Specification

085319c 5 07.06.15

Dual drapery track systemAlena drapery tracks can be used for a combination sheer/blackout treatment.

Dimensions*

11.25 in (286 mm)

3.5 in (89 mm)

2.5 in (64 mm)

1 in (25 mm)

Dimensions*

11.25 in (286 mm)

3.5 in (89 mm)

2.5 in (64 mm)

1 in (25 mm)

5.5 in (140 mm)

Single drapery track systemMaintain enough clearance between the drapery track and the inside face of the top treatment or ceiling recess to allow the fabric to move freely.

Plan View (mounting details not shown)

Plan View (mounting details not shown)

Elevation View

Elevation View

Page 6: Alena Drapery System - Lutron Electronics · Alena ™ Drapery System System Specification 085319c 1 07.06.15 ... • Pressing any button on a keypad while the drape is moving will

Ceiling

Washer

CamLock

SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Alena™ Drapery System System Specification

085319c 6 07.06.15

Mounting Options

Ceiling Mount

Recess Mount

1½ inch Wood Screw

Structural Member

Recessed Pocket

Recessed Mounting Bracket

Drapery Track

2.25 in (57 mm)Minimum Pocket Width

1 1/16 inch (27 mm)Minimum Pocket Depth

2.25 in (57 mm)Minimum Pocket Width

3 inch Drywall Anchor Screw

Drywall Anchor

Recessed Pocket

Recess-Mount Bracket

1 1/16 inch (27 mm)Minimum Pocket Depth

1/2 inch (13 mm) hole

Drywall

1.3 in (31.8 mm)

Structural Member

Drapery Track1.2 in(31 mm)

Recess-Mount Bracket(qty. varies with track length)

Cam Lock

Washer

Ceiling

Ceiling

Drapery Track

Page 7: Alena Drapery System - Lutron Electronics · Alena ™ Drapery System System Specification 085319c 1 07.06.15 ... • Pressing any button on a keypad while the drape is moving will

SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Alena™ Drapery System System Specification

085319c 7 07.06.15

Drapery fabric

Adjustment of the drapery pin height may be necessary to align these pleats with the other pleats on the drapery panel.

Pinch PleatLutron recommends a drapery hook setting of 1/2 in (13 mm) from the top of the drape to the top of the hook (hooks not included). This locates the drapes just below the track and prevents it from rubbing on the track. It is recommended that a distance of 1/2-1 in (13-25 mm) be maintained between the bottom of drapery panel and the floor.

Dressing the Drape Around the Drive End

Hanging Drapery Fabric

1/2 in (13 mm)

Top of drapery panel

Floor

Bottom of drapery track

5/8 in(16 mm)

1/2-1 in (13-25 mm)

Bottom of drapery panel

Drapery panel height +5/8- 1 1/8 in (16-29 mm)

Page 8: Alena Drapery System - Lutron Electronics · Alena ™ Drapery System System Specification 085319c 1 07.06.15 ... • Pressing any button on a keypad while the drape is moving will

SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Alena™ Drapery System System Specification

085319c 8 07.06.15

AlenaTM Drapery System | Single Drive Wiring

Wiring types Purpose Wire optionsA Contact Closure input/output 18-22 AWG (1.00-0.50 mm²)

per contact closure - 250 ft (75 m) max

B Drive power (power supply to Drive) 12 AWG - (4 mm²)-250 ft (75 m) max16 AWG - (1.5 mm²)-100 ft (30 m) maxLutron P/N QSHY-CBL-M-1000 Non-plenumLutron P/N QSHY-CBLP-M-1000 plenum18 AWG - (1 mm²)-50 ft (17 m) max

Notes: • Standalone draperies can be controlled with a keypad, or via manual activation. • Pressing any button on a keypad while the drape is moving will cause the drape to stop.• The contact closure device must be capable of switching 24V- with a minimum contact closure time of 0.25 seconds (for

each link)

MU

X

MU

X

Com

MU

X

MU

X

+24

V-

Com

QSPS-P1-1-50

Power Supply Models

NEMA 5-15 Plug

QSPS-P2-1-50CEE 7/7Plug

QSPS-P3-1-50BS 1363 Plug

QSPS-P4-1-50PSE Plug

Wire Type A

Wire Type B

Terminal block of drive controlling single drape

4-pin EDU connector

* All switch contacts are momentary and normally open

Power Supply

AlenaTM Drapery

Drive

Page 9: Alena Drapery System - Lutron Electronics · Alena ™ Drapery System System Specification 085319c 1 07.06.15 ... • Pressing any button on a keypad while the drape is moving will

MU

X

MU

X

Com

MU

X

MU

X

+24

V-

Com

QSPS-P1-1-50

Power Supply Models

NEMA 5-15 Plug

QSPS-P2-1-50CEE 7/7Plug

QSPS-P3-1-50BS 1363 Plug

QSPS-P4-1-50PSE Plug

MU

X

MU

X

Com

MU

X

MU

X

+24

V-

Com

QSPS-P1-1-50

Power Supply Models

NEMA 5-15 Plug

QSPS-P2-1-50CEE 7/7Plug

QSPS-P3-1-50BS 1363 Plug

QSPS-P4-1-50PSE Plug

SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Alena™ Drapery System System Specification

085319c 9 07.06.15

AlenaTM Drapery System | Dual Drive Wiring

Wiring types Purpose Wire optionsA Contact Closure input/output 18-22 AWG (1.00-0.50 mm²)

per contact closure - 250 ft (75 m) max

B Drive power (power supply to Drive) 12 AWG - (4 mm²)-250 ft (75 m) max16 AWG - (1.5 mm²)-100 ft (30 m) maxLutron P/N QSHY-CBL-M-1000 Non-plenumLutron P/N QSHY-CBLP-M-1000 plenum18 AWG - (1 mm²)-50 ft (17 m) max

Terminal block of drive controlling single drape

Power Supply

Power Supply

Dual group keypad

Wire Type A

Wire Type B

Wire Type B

AlenaTM Drapery

Drive

AlenaTM Drapery

Drive

* All switch contacts are momentary and normally open

4-pin EDU connector

Notes: • Standalone draperies can be controlled with a keypad, or via manual activation. • Pressing any button on a keypad while the drape is moving will cause the drape to stop.• The contact closure device must be capable of switching 24V- with a minimum contact closure time of 0.25 seconds (for

each link)

Page 10: Alena Drapery System - Lutron Electronics · Alena ™ Drapery System System Specification 085319c 1 07.06.15 ... • Pressing any button on a keypad while the drape is moving will

SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Alena™ Drapery System System Specification

085319c 10 07.06.15

CC

O 1

NC

CC

O 1

NO

1-2

CO

MC

CO

2 N

CC

CO

2 N

OC

CO

3 N

CC

CO

3 N

O3-

4 C

OM

CC

O 4

NC

CC

O 4

NO

CC

O 5

NC

CC

O 5

NO

5 C

OM

CC

I 1C

CI 2

CC

I 3C

CI 4

CC

I 5C

OM

+PW

RC

OM

MU

XM

UX

Contact Closure Outputs (CCO)

Contact Closure Inputs (CCI)

MU

X

MU

X

Com

MU

X

MU

X

+24

V-

Com

QSPS-P1-1-50

Power Supply Models

NEMA 5-15 Plug

QSPS-P2-1-50CEE 7/7Plug

QSPS-P3-1-50BS 1363 Plug

QSPS-P4-1-50PSE Plug

AlenaTM Integrated System | Single Drive Wiring

QSE-IO Contact Closure Interface

Wiring types Purpose Wire optionsA Contact Closure input/output 18-22 AWG (1.00-0.50 mm²)

per contact closure - 250 ft (75 m) max

B Drive power (power supply to Drive) 12 AWG - (4 mm²)-250 ft (75 m) max16 AWG - (1.5 mm²)-100 ft (30 m) maxLutron P/N QSHY-CBL-M-1000 Non-plenumLutron P/N QSHY-CBLP-M-1000 plenum18 AWG - (1 mm²)-50 ft (17 m) max

Wire Type A

Wire Type B

Notes: • QSE-IO outputs programmed as a 0.25 second momentary contact closure output• Activating Open or Close while the drape is moving will cause it to stop

Terminal block of drive controlling single drape

Power Supply

AlenaTM Drapery

Drive

4-pin EDU connector

Page 11: Alena Drapery System - Lutron Electronics · Alena ™ Drapery System System Specification 085319c 1 07.06.15 ... • Pressing any button on a keypad while the drape is moving will

SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Alena™ Drapery System System Specification

085319c 11 07.06.15

CC

O 1

NC

CC

O 1

NO

1-2

CO

MC

CO

2 N

CC

CO

2 N

OC

CO

3 N

CC

CO

3 N

O3-

4 C

OM

CC

O 4

NC

CC

O 4

NO

CC

O 5

NC

CC

O 5

NO

5 C

OM

CC

I 1C

CI 2

CC

I 3C

CI 4

CC

I 5C

OM

+PW

RC

OM

MU

XM

UX

Contact Closure Outputs (CCO)

Contact Closure Inputs (CCI)

MU

X

MU

X

Com

MU

X

MU

X

+24

V-

Com

QSPS-P1-1-50

Power Supply Models

NEMA 5-15 Plug

QSPS-P2-1-50CEE 7/7Plug

QSPS-P3-1-50BS 1363 Plug

QSPS-P4-1-50PSE Plug

MU

X

MU

X

Com

MU

X

MU

X

+24

V-

Com

QSPS-P1-1-50

Power Supply Models

NEMA 5-15 Plug

QSPS-P2-1-50CEE 7/7Plug

QSPS-P3-1-50BS 1363 Plug

QSPS-P4-1-50PSE Plug

Wire Type A

Wire Type B

Wire Type B

Wiring types Purpose Wire optionsA Contact Closure input/output 18-22 AWG (1.00-0.50 mm²)

per contact closure - 250 ft (75 m) max

B Drive power (power supply to Drive) 12 AWG - (4 mm²)-250 ft (75 m) max16 AWG - (1.5 mm²)-100 ft (30 m) maxLutron P/N QSHY-CBL-M-1000 Non-plenumLutron P/N QSHY-CBLP-M-1000 plenum18 AWG - (1 mm²)-50 ft (17 m) max

Notes: • QSE-IO outputs programmed as a 0.25 second momentary contact closure output• Activating Open or Close while the drape is moving will cause it to stop

Terminal block of drive controlling single drape

Power Supply

Power Supply

AlenaTM Drapery

Drive

AlenaTM Drapery

Drive

AlenaTM Integrated System | Dual Drive Wiring

4-pin EDU connector

QSE-IO Contact Closure Interface

Page 12: Alena Drapery System - Lutron Electronics · Alena ™ Drapery System System Specification 085319c 1 07.06.15 ... • Pressing any button on a keypad while the drape is moving will

SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Alena™ Drapery System System Specification

085319c 12 07.06.15

Lutron World HeadquartersLutron Electronics Co., Inc.7200 Suter RoadCoopersburg, PA 18036United States1.888.LUTRON1Tel: +1.610.282.3800Fax:+1.610.282.1243

European HeadquartersLutron EA Ltd.6 Sovereign CloseLondon, E1W 3JFUnited KingdomTel: +44.(0)20.7702.0657Fax: +44.(0)20.7480.6899

Asian HeadquartersLutron GL Limited390 Havelock Road#07-04 King’s CentreSingapore 169662Tel: +65.6220.4666Fax: [email protected]

FranceParis Lutron LTC SARL- Paris54/56 avenue Hoche Paris, 75008Phone: +33.1.56.59.16.64Toll Free (In-country only): [email protected]

GermanyLutron Electronics GMBH BerlinPhone: +49.309.710.4590Toll Free (In-country only): [email protected]

ItalyLutron LDV S.r.lPhone: [email protected]

SpainLutron CC, SRL c/ Herzeg ovina, 3. Local 2Barcelona, 08021Phone: +34.93.222.1180Toll Free (In-country only): [email protected]

Singapore (Regional Offi ce)Lutron GL Limited390 Havelock Road,#07-04 King’s CentreSingapore, 169662Phone: +65.6220.4666Fax: [email protected]

ChinaLutron GL Electronics Co. Ltd.Pudong Branch Offi ceShanghai World Financial Center17th Floor, No. 100Century Ave. Pudong, Shanghai, 200120Phone: +86.21.6165.0990Fax: [email protected]

Lutron GL Electronics Co. Ltd.Beijing Branch Offi ce5th Floor, China Life TowerNo. 16, Chaowai St.Chaoyang District, Beijing 100020Phone: +86.10.5925.1340Fax: [email protected]

Hong KongLutron GL LtdUnit 2808, 28/F248 Queens Road EastWanchai Hong KongPhone: +852.2104.7733Fax: [email protected]

Tokyo (Regional Offi ce)Lutron Asuka Co., Ltd.NOF Tameike Bldg. 9F1-1-14 Akasaka, Minato-kuTokyo, 107-0052Phone: +81.3.6866.8444Fax: [email protected]

India-GurgaonLutron GL Sales and Services Pvt. Ltd.Building 8A, 5th FloorDLF CybercityGurgaon, Haryana 122002Phone: +91 124 439 0130Fax: +91 124 439 [email protected]

India-MumbaiLutron GL Sales and Services Pvt. Ltd.Trade Centre, Regus1st Floor, Bandra Kurla ComplexBandra (E), Mumbai 400051Phone: +91 22 4070 [email protected]

India-BangaloreLutron GL Sales and Services Pvt. Ltd.15th Floor,Concorder TowersU.B.City, 1 Vittal Mallya RoadBangalore, Karnataka 560001Phone: +91 80 4030 [email protected]

China – GuangzhouLutron GL Electronics Co. Ltd.Guangzhou Branch Offi ceRoom B12, Tower A, 23/F, Centre PlazaNo. 161 Lin He Xi RoadTianhe District, Guangzhou 510620Phone: [email protected]

Russia – MoscowLutron Russia (Lutron Electronika)Ul. Pravdy, 8-13 125040Phone: [email protected]

UAE – DubaiLutron GL Ltd6EB building – 1st Floor, Offi ce #145Dubai Airport Free ZoneP.O. Box 54759Phone: +971.4.299.1224Fax: +971.4.299. [email protected]

Saudi ArabiaLutron EA LimitedBranch Offi ce #303Sada 1 , 3rd FloorOlaya District8306 Awal ValleyP.O. Box 301129Riyadh 11372Phone: +966 11 466 1546Fax: +966 11 462 [email protected]

Latin AmericaBrasil Lutron BZ do Brasil LtdaAvenida Ibirapuera2064/ 7o andar- cj. 72MoemaSão Paulo, SP 04.028-001Phone: +55 11 3257 [email protected]

ColombiaLutron Electronics de Colombia S.A.S.Carrera 13 #96-67Ofi cina 607, Edifi co A KoryBogota, ColombiaPhone: [email protected]

Chihuahua, MexicoLutron CN S de RL de CVRudyard Kipling, 11530Complejo Industrial ChihuahuaCp 31136 MEXICOPhone: +52 (614) [email protected]

South Africa – JohannesburgLutron South Africa (Pty) LtdP.O. Box 3094HoughtonJohannesburg, 2041Phone: + 27.(0)[email protected]

Customer Service & OrderingUSA and Canada: 1.800.446.1503 – 08.00 - 19.00 EST

UK +44.(0)20.7702.0657 – 09.00 - 18.00 GMT

[email protected]

lutron.com/shadingsolutions

Technical Support & ServicesUSA and Canada: +1.800.523.9466 (24 hrs / 7 days)

UK +44.(0)20.7680.4481 – 08.00 - 18.00 GMT

[email protected] | forums.lutron.com

For product warranty information, please see: lutron.com/TechnicalDocumentLibrary/Window Systems Warranty.pdf

Asian Headquarters | SingaporeLutron GL Ltd.390 Havelock Road,#07-04 King’s CentreSingapore, 169662TEL: +65.6220.4666FAX: [email protected]

Worldwide Headquarters | USALutron Electronics Co., Inc.7200 Suter RoadCoopersburg, PA 18036-1299 USATEL: 1.610.282.3800FAX: 1.610.282.3090Technical Support: 1.800.523.9466Toll Free: [email protected]/shadingsolutions

Europe Headquarters | United KingdomLutron EA Ltd6 Sovereign CloseLondon, E1W3JF, UKTEL: +44.(0)20.7702.0657FAX: +44.(0)20.7480.6899Technical Support: +44.(0)20.7680.4481FREEPHONE: 0800.282.107