S.no Alarm no Descriptions1 510000 FEED HOLD KEY ON MACHINE CONTROL PANEL PRESSED
Cause Feed stop button on the MCP is pressedRemedy Press the feed start button on the MCP to cancel the alarm
2 510001 WAIT FOR SPINDLECause Spindle is started.It is not yet reached the set speedRemedy The alarm will be automatically cancelled once the spindle rpm reaches the set speed
3 510002 GANTRY NOT SYNCHRONIZED.PLEASE SELECT REFERENCE MODE.FEED HOLD ACTIVECause Gantry not yet synchronizedRemedy Please select the reference mode to cancel the alarm
4 510100 TOOL NOT CLAMPED IN THE SPINDLE PROPERLYCause Spindle is in unclamped conditionRemedy Clamp the spindle and start the cycle
5 510102 TOOL NOT CLAMPED IN THE SPINDLE PROPERLYCause New tool was called without physical tool in the tool rackRemedy Reset the alarm put the tool in the tool rack and then call the tool
6 510103 TOOL CHANGER NOT IN HOME/REVERSE POSITIONCause Tool changer not in home positionRemedy Bring the tool changer to home position to cancel the alarm.To retract tool changer make M1.0=1
7 510104 TOOL CHANGER IN/OUT TIME OUT ALARMCause Tool changer in/out operation time out alarmRemedy Check the tool changer operation and eliminate the cause.To retract tool changer make M1.0=1
8 510105 WAITING FOR DRIVE READY.FEED HOLD/READ IN DISABLE ACTIVECause NC waitig for drives to get readyRemedy The alarm will be cancelled automatically once the drives are ready
9 510106 SPINDLE MOTOR THERMAL OVERLOAD.FEED HOLD/READ IN DISABLE ACTIVECause Spindle motor thermal input is not okRemedy Check the spindle motor for thermal overload and eliminate the cause
10 510107 SPINDLE AMPLIFIER ERROR.FEED HOLD/READ IN DISABLE ACTIVECause Spindle amplifier input not okRemedy Check the amplifier and eliminate the cause of the input
11 510108 AIR PRESSURE NOT OK.FEED HOLD/READ IN DISABLE ACTIVECause Air pressure not okRemedy Switch on the compressor.Check the pressure developed from the compressor is equal to 6 bar.
To disable air pressure switch make M2.0=112 700000 PRESS MACHINE ON PUSH BUTTON ON MCP
Cause Machine on push button not pressedRemedy Please press machine on push button on the MCP to cancel the alarm
13 700001 HAND HELD MPG ACTIVECause Hand held MPG is enabled in the jog modeRemedy No remedy.This is an operator message
14 700002 SPINDLE HOLD KEY ON MACHINE CONTROL PANEL PRESSEDCause Spindle stop button on the MCP is pressedRemedy Press the spindle start button on the MCP to cancel the alarm
15 700007 PLEASE ACKNOWLEDGE GANTRY SYNCHRONIZATION START BUTTONCause Gantry synchronization is waiting for acknowledgementRemedy Press the gantry synchronization button on the MCP to start gantry synchronization
16 700008 MEASURING PROBE NOT ACTUATEDCause Measuring probe not actuatedRemedy Reset to cancel the alarm.The measuring probe iS not actuated within the defined distance
17 700009 NO TOOL CLAMPED IN THE SPINDLECause No tool is clamped in the spindleRemedy Reset to cancel the alarm.Continue the operation with tool in the spindle