ALARMS & INDICATION

42
HUMIDITY ALARMS & INDICATION RAD-1 | p. 66 51XBR Series | p. 69 AIS | p. 65 MNST/MST1 | p. 92 Series 869/869STR | p. 67 ST120 Series | p. 90 ALARMS & INDICATION P il l a Electrical Products, Inc. P il l a Electrical Products, Inc. Kele Offers Custom Assemblies and FREE Display Calibrations.

Transcript of ALARMS & INDICATION

Page 1: ALARMS & INDICATION

HU

MID

ITY

ALARMS & INDICATION

RAD-1 | p. 66

51XBR Series | p. 69

AIS | p. 65

MNST/MST1 | p. 92 Series

869/869STR | p. 67

ST120 Series | p. 90

AL

AR

MS

&

IND

ICA

TIO

N

PillaElectricalProducts, Inc.

PillaElectricalProducts, Inc.

Kele Offers Custom Assemblies and FREE Display Calibrations.

Page 2: ALARMS & INDICATION

MODEL/SERIES PAGEProducts manufactured in the United States

Products that are new to the catalog

ke le .com

200 Class | p. 80 ClearView

ESM Series | p. 86

ESP Series | p. 88

ALARMS & INDICATIONA

LA

RM

S &

IN

DIC

AT

ION

Alarm and Indication StationsAIS — Kele Alarm Indication Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65RAD-1 — Kele Remote Alarm Indication Station . . . . . . . . . . . . . . . . . . . . . . . 66 Emergency Operator StationsE-Stop ESB Series — Operator Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84E-Stop ESM Series — Emergency Operator Stations . . . . . . . . . . . . . . . . . . . 86E-Stop ESP Series — Emergency Operator Stations . . . . . . . . . . . . . . . . . . . 88ST120 Series — Operator Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90WPS Series — Plate Mounted Operator Stations . . . . . . . . . . . . . . . . . . . . . . . 91MNST and MST1 Series — Power Control Stations . . . . . . . . . . . . . . . . . . . . 92 Loop Powered IndicatorsVPI Series — 3-1/2 Digit LCD Panel Display . . . . . . . . . . . . . . . . . . . . . . . . . . 93SGD-24, -28 — PanelPilot Smart Graphical Display . . . . . . . . . . . . . . . . . . . . . 94BDR Series — Kele Big Display Readout, 3-1/2 Digit LED, Red / Blue /

Green . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96LPI-1C — 3-1/2 Digit LCD Panel Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97LPI-1C-A, LPI-1C-G, LPI-1C-R — 3-1/2 Digit LCD Amber / Green / Red

Panel Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98LPI-3C, LPI-3C-A, LPI-3C-G or LPI-3C-R — 4-1/2 Digit Black / Amber /

Green / Red Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99LPI-4 — Kele 3-1/2 Digit Large Black / Red / Green / Amber Panel Display . . 100LPI-5 — Kele 3-1/2 Digit Small Black / Red Panel Display . . . . . . . . . . . . . . . 101 Multi-Status Indicators105XBRi Series — XTRA-BRITE LED Multi-Status Indicator . . . . . . . . . . . . . 76125XBRi Series — XTRA-BRITE LED Multi-Status Indicator . . . . . . . . . . . . . 78 Run Time AccumulatorALD-1 — Pulse or Run-time Accumulator Display . . . . . . . . . . . . . . . . . . . . . 102 Strobes and Horns125STR, 89STR, 869STR, 869, 868STR, 868 — Strobes & Horns . . . . . . . . . 67SC-Series — Alarm Horn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68STB, STB-H — Wall-Mounted Strobe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6851XBR Series — XTRA-BRITE LED Beacon with Horn . . . . . . . . . . . . . . . . . . 6957 Series — Polaris Class LED Beacon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7094 Series — Polaris Class LED Beacon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71107XBR Series — XTRA-BRITE LED Hazardous Location Beacon . . . . . . . . 72105XBRM Series — XTRA-BRITE LED Adverse Location Visual Signals . . . . 74125XBR Series — XTRA-BRITE LED Beacons . . . . . . . . . . . . . . . . . . . . . . . . 75 Tower Lights200 Class ClearView — LED Stacklight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80TWS Series — 75 mm Tower Lights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

Page 3: ALARMS & INDICATION

NEW!

65

ALARMS & INDICATIONALARM

S & INDICATION

2

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

Supply Voltage 24 VAC/ VDC, 120 VAC, 100 mA max

Contact Rating AIS-24D 24 VDC, 50 mA min AIS-24A 24 VAC, 90 mA min AIS-120A 120 VAC, 70 mA minAlarm Horn 80 dbDimensions 7 .09"H x 4 .33"W x 3 .54"D

(18 .0 x 11 .0 x 9 .0 cm)Mounting Four screws through back Enclosure Polystyrene, impact resistant,

knock-outsApprovals RoHSWeight 1 .1 lb (0 .5 kg)Warranty 1 year

KELE ALARM INDICATION STATION

DESCRIPTION

The Model AIS Alarm Indication Station features an indication light, alarm horn and an alarm horn silence switch .

FEATURES• Long lasting, red LED indication • Distinct continuous audible tone• Horn silence switch• Compact and rugged design• Available in 24 VDC, 24 VAC, or 120 VAC• Bright yellow panel face

Power Supply*

Controlling Device 4 3 2 1

(+)(+) (–)(–)

L

H

S

(Alarm initiated bycontact closure)

Red LED Light

Alarm horn, 80 db

Alarm HornSilence Switch

* Power must be supplied to the AIS

AIS

1

2

3

4

5 N.C.

Four-wire connection

Two-wire connection

Power supply24 VAC/VDC or 120 VAC

Remote alarm deviceAlarm initiated bycontact closure

A power interrupt or open alarm contactwill reset the AIS to normal.

A power interrupt or open alarmcontact will reset the AIS to normal.

AIS internalterminal strip

1

2

3

4

5 N.C.

Power supply24 VAC/VDC or 120 VAC

Remote alarm deviceAlarm initiated bycontact closure

AIS internalterminal strip

N.C.

N.C.

N.C.=no connection

N.C.=no connection

WIRING

APPLICATION• Refrigerant leak alarm indication• Water level alarm indication• Pressure alarm indication• High/Low temperature limits• Gas leak indication• Humidity limit alarm indication• Vibration limit• Voltage/Current level limit• Any contact closure alarm application

SEQUENCE OF OPERATIONUpon an alarm contact closure, the LED indicator will light, and the horn will sound . The horn can be silenced through the alarm silence switch, while the visual indication will continue to be lighted until the alarm condition has been corrected . A power interruption or open alarm contact will reset the AIS .

SPECIFICATIONS

ORDERING INFORMATION

MODEL DESCRIPTIONAIS Alarm indication station 12VD 12 VDC powered 24D 24 VDC powered 24A 24 VAC powered 120A 120 VAC powered

Example: AIS-24A 24 VAC powered alarm indication stationAIS 24A

March 2014

Page 4: ALARMS & INDICATION

ALARMS & INDICATION

66

ALAR

MS &

INDI

CATI

ON

2

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014March 2014

NEW!

Supply Voltage 24 VAC @ 100 mA or 24 VDC @ 34 mA

Alarm Delay Time None, or 1 to 31 seconds in one-second increments, or 10 to 310 seconds in 10-second increments

Alarm Horn Continuous or pulsed tone, 70 db min

Alarm Repeat Time None, or 1 to 7 in one-minute increments, or 10 to 70 minutes in 10-minute increments

Alarm Status Relay SPDT, 0 .5A @ 24 VAC, 1 .0A @ 30 VDC

Connections Screw terminals, 22 - 14 AWG wires Dimensions 4 .5"H x 2 .75"W x 1 .0"D

(11 .4 x 7 .0 x 2 .5 cm)Mounting Brushed stainless steel plate mounts

to standard single junction box, two screws provided

Approvals RoHSWeight 0 .19 lb (0 .07 Kg)Warranty 18 months

DESCRIPTIONThe RAD-1 is a wall mounted remote alarm indication station mounted on a stainless steel plate . Any contact closure alarm initiating device that can switch 24 VAC or DC can be used with the RAD-1 .

FEATURES• Red alarm LED• Alarm horn, continuous tone or pulsed• Alarm horn silence switch• Adjustable alarm delay time• Adjustable alarm repeat time• Alarm status SPDT relay• Relay operates with the alarm horn option

8

7

6

5

4

3

2

1

ON OFF

16

1

Repeattime inminutes

(add)

Repeattime in

seconds(add)

HORN PULSED

REPEAT TIME x10

DLY TIME x10

Relayfollowshorn

Alarm Repeat after Silence Time*SW6–SW8 OFF = No delaySW6 ON = 1 minuteSW7 ON = 2 minutesSW8 ON = 4 minutesInitial Alarm Delay Time*SW1–SW5 OFF = No delaySW1 ON = 1 secondSW2 ON = 2 secondsSW3 ON = 4 secondsSW4 ON = 8 secondsSW5 ON = 16 seconds

RAD-1

24VAC/VDC

Relay Alarmrelay

+

NO

COM

NC

NO

COM

NC

+

Alarm initiatingdevice

No jumper Jumper installed

* Times are additive; for example, with SW3 and SW5 both ON, 4 sec + 16 sec = 20 sec delay (or 200 sec if DLY TIME x10 jumper is installed)

Initial alarmdelay time x1

Continuous horn Pulsed horn

1

2

4

2

4

8

•Alarm repeatafter silencetime x1

•Alarm repeatafter silencetime x10

Inital alarmdelay time x10

WIRING

SEQUENCE OF OPERATIONWhen 24 VAC or VDC is applied to the RAD-1 through an alarm-initiating device, the red alarm LED will light, the horn will sound, and the alarm status relay will energize . If an initial alarm delay has been set, when 24 VAC or VDC is applied, the red alarm LED will blink until the delay period has expired . Then it will light continuously, the horn will sound continuously, and the relay will energize . If power is interrupted, the RAD-1 will reset to normal state .

During an alarm (24V applied to the RAD-1), the horn may be silenced by momentarily pressing the silence switch . The alarm LED will remain lighted, and the alarm status relay will remain energized when the horn is silenced until the alarm condition is cleared (24V removed) . If an alarm repeat after silence time has been set, the horn will re-sound at the end of the repeat time . If the relay-follows-horn jumper is installed, the alarm status relay will de-energize when the horn is silenced and re-energize when the horn sounds at the end of the repeat-after-silence time .

If a pulsed (instead of continuous tone) horn is desired, the horn-pulsed jumper may be installed . If both the horn pulsed jumper and the relay-follow-horn jumper are installed, the alarm status relay will energize and de-energize with the pulsed horn .

KELE REMOTE ALARM INDICATION STATIONRAD-1

SPECIFICATIONS

ORDERING INFORMATION

MODEL DESCRIPTIONRAD-1 Remote alarm indication station

Page 5: ALARMS & INDICATION

NEW!

67

ALARMS & INDICATIONALARM

S & INDICATION

2

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014March 2014

NEW!Supply Voltage N5 (89, 869, 868) 120 VAC AQ (89, 869, 868) 24 VDC, 24 VAC 120A (125STRH) 120 VAC -20% to +10% of nominal

voltageCurrent Rating 125STRH 120 mA Horn/Strobe 24 VDC, 22 mA/390 mA 24 VAC, 72 mA/390 mA 120 VAC, 24 mA/87 mAAverage Candela Amber 90 cd Blue 20 cd Clear 150 cd Green 70 cd Red 21 cdColor Amber, blue, clear, green, redHorn Loudness 90 dba @ 10'Peak Candela 300,000 cdStrobe Tube Life 3,000 hrs, 1,000 hrs

Operating Humidity 868, 868 STR 95% RH @ 86°F (30°C) 869, 89 STR, 869 STR 85% RH @ 86°F (30°C)Operating Temperature 868, 868 STR -31° to 150°F (-35° to 66°C) 869, 89 STR, 869 STR 32° to 120°F (0° to 49°C)Dimensions 89 STR 5"H x 3-3/8"W (12 .7 x 8 .6 cm) 869 STR, 868 STR, 869, 868 5-1/2"H x 5-1/2"W (14 x 14 cm), Enclosure Rating 125 STRH NEMA 4XMounting 868 Weatherproof surface box supplied –

no NEMA rating 869 3" sq x 1-1/2" electrical box with 1-1/2"

extension ring (need 3" depth)Approvals UL 1638 listed, cULWarranty 2 years

DESCRIPTIONSignal strobes and horns available in wall-mount and panel-mount configurations with a variety of colors and voltages . Model 125STR is a 120 VAC panel-mount strobe in NEMA 4X enclosure . Model 89STR mounts on a single-gang box and is a single, indoor, flush-mount strobe . Model 869STR is an indoor, flush-mount horn and strobe combination . Model 869 is an indoor, flush-mount horn only . Model 868 STR is an outdoor, surface-mount horn and strobe combination . Model 868 is an outdoor, surface-mount horn .

FEATURES• Indoor and outdoor applications• Amber, blue, clear, green, and red colors• 24 VAC, 24 VDC, and 120 VAC• Surface and panel mount

868 STR/869 STR Horn/Strobe

Strobe Horn

+

+

WIRING

STROBES & HORNS125STR, 89STR, 869STR, 869, 868STR, 868

SPECIFICATIONS

ORDERING INFORMATION

868STR B AQ Example: 868STR-B-AQ Outdoor surface- mount electronic horn with blue strobe and 24 VAC/VDC

MODEL DESCRIPTION125STRH Panel-mount strobe89STR Indoor flush-mount strobe869STR Indoor flush-mount electronic horn/strobe868STR Outdoor surface-mount electronic horn/strobe869 Indoor flush- or panel-mount electronic horn868 Outdoor surface-mount electronic horn COLOR A Amber B Blue C Clear G Green R Red SUPPLY VOLTAGE AQ 24 VAC/VDC (89, 869, 868) N5 120 VAC (89, 869, 868) 120A 120 VAC (125STRH only)

869 869STR

868STR 125STRH

Page 6: ALARMS & INDICATION

ALARMS & INDICATION

68

ALAR

MS &

INDI

CATI

ON

2

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

NEW!

Supply Voltage 20-31 VDC (24 VDC nominal)Current Rating STB 80 mA at 24 VDC STB-H 136 mA at 24 VACStrobe Frequency 1 HzHorn Loudness 104 dB maxStrobe Intensity 15 (off-center) candela 75

(on-center) candelaOperating Temperature 32° to 120°F (0° to 49°C)Dimensions 4 .5"H x 4 .56"W x 2 .25"D (11 .43 x 11 .58 x 5 .72 cm)WeightSTB 1 .0 lb (0 .45 Kg)STBH 1 .1 lb (0 .5 Kg)Approvals UL Listed File S3406Warranty 3 years

Supply Voltage SC110 30-120 VAC/VDC SC628 6-28 VDC SC628A, AN 6-28 VAC/VDCCurrent Rating SC100 6-21 mA SC628 3-18 mA SC628AN 4-30 mA SC628A 6-23 mAHorn Loudness Medium, 68-80 dB

(AN model Loud, 80-95 dB)Tone ContinuousPanel Cutout Panel, cutout 1 .13" (2 .87 cm)Weight 0 .1 lb (0 .05 Kg)Approvals UL recognized component File# S1290Warranty 1 year

ALARM HORNSC-SERIES

DESCRIPTIONThe SC Series Alarm Horns provide an audible tone when an electric signal is applied . They can be used in applications when an audible alarm is needed to indicate that immediate attention is required .

SPECIFICATIONS

ORDERING INFORMATION

MODEL DESCRIPTIONSC110 Alarm horn, 120 VACSC628 Alarm horn, 24 VDCSC628A Alarm horn, 24 VAC/VDCSC628AN Alarm horn, 24 VAC/VDC

WALL-MOUNTED STROBESTB, STB-H

DESCRIPTIONThe Model STB and STB-H wall-mounted strobes provide a bright, eye-catching warning light for any alarm application . The STB-H features a distinct audible signal .

FEATURES• Wall mounted with 4" square or double-gang box• Integral alarm horn (91 db)• 24 VDC powered• 15/75 candela strobe intensity• Meets requirements of ADA4.28.3• UL listed• Xenon strobe for constant flash rate• Strobe and horn powered separately if desired• Jumper-selectable, continuous or temporal tone

SPECIFICATIONS

ORDERING INFORMATION

MODEL DESCRIPTIONSTB Wall-mounted strobeSTB-H Wall-mounted strobe with horn

WIRING

WIRING

SC Horn

Horn+

Note: Switch 1, 2 off

Signal

++

––

S+ S+ S- H- H+

March 2014

Page 7: ALARMS & INDICATION

NEW!

69

ALARMS & INDICATIONALARM

S & INDICATION

2

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014March 2014

NEW!

DIMENSIONS

1/2"(12.7mm)

conduit hole

3 1/2"(89mm)

3/4" (19.05mm)

6"(152mm)

7 3/8"(187mm)H

in(cm)

W

DESCRIPTIONThe 51XBR Series XTRA-BRITE™ LED beacons are combination visual and audible signaling devices, designed for indoor or outdoor applications . The integrated horn is synchronized with the flashing LED . The unit features a cast metal base that can be used as a junction box . The double fresnel lens is made of shatter-resistant polycarbonate, and is designed to magnify the superbright LED .

FEATURES• LED light source with integrated horn• Shatter-resistant double fresnel polycarbonate lens• Five lens color options• Immune to shock and vibration• Cast metal base• Suitable for indoor and outdoor applications

XTRA-BRITE LED BEACON WITH HORN51XBR SERIES

Supply Voltage 51XBRFx120A 120 VAC, 50/60 Hz, 51XBRFx24D 24 VDCCurrent 51XBRFx120A 175 mA 51XBRFx24D 275 mAMax. Off State Leakeage Current 10 mASurge (inrush / duration) 51XBRFx120A 50 A / 260 μs 51XBRFx24D 10 A / 120 μsColors Amber, blue, green,red, white Flash Rate 65 FPMProjected LED Life 148,000 hoursHorn Loudness 85 dB @10'Strobe Tube Life 148,000 hoursOperating Temperature -31°F to 150°F (-35°C to 66°C)Dimensions 7 .38"H x 6"W (18 .7cm x 15 .2cm)Mounting• Direct surface mount• Mounted on 1/2 in. NPT conduit• Mounted on a 4 in. octagon boxApprovals cULus Listed, uLWeight 2 .14lbs (0 .97 kg)Warranty 18 months

SPECIFICATIONS

ORDERING INFORMATION

MODEL DESCRIPTION51XBRF Combination flashing LEDs with horns COLOR A Amber B Blue G Green R Red W White SUPPLY VOLTAGE 24D 24 VDC 120A 120 VAC @ 50/60 Hz

57PLEDM G 24D Example: 51XBRFG24D Combination flashing LEDs with horns and 24V DC

51XBR

WIRING

24 VDCWIRING

RE

D

BLA

CK

+ –B

LAC

K

WH

ITE

120 VACWIRING

24 VDCPOWER

120 VACPOWER

+

GR

EE

N

GND – NEUTRAL

Wire nuts not included.

Page 8: ALARMS & INDICATION

ALARMS & INDICATION

70

ALAR

MS &

INDI

CATI

ON

2

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014March 2014

POLARIS CLASS LED BEACON57 SERIES

DESCRIPTIONEdwards Polaris Class 57PLEDM LED beacons are NEMA Type 4X and IP66 rated visual signals designed for indoor and outdoor applications .The Polaris Class is designed for industrial or commercial applications that require the longevity of an LED combined with the brightness of a xenon strobe . These units are very effective in high noise areas where ear protection is worn or audible signals may not be heard .

FEATURES• Six lens colors• Seven flash patterns (includes steady-on)• Hidden in Plain Sight (HIPS) switch• High level of immunity to shock and vibration• Black or gray base option

Supply Voltage 57PLEDMx24ADx 12 VDC, 0 .7A, 24 VAC/VDC, 0 .55A 57PLEDMx120Ax 120 VAC, 50/60Hz, 0 .25ALeakage Current Off State Leakage 5 mASurge Current 57PLEDMx24ADx 8 .5A/2ms 57PLEDMx120Ax 4 .5A/1msColor Amber, blue, green, magenta, red, clearProjected LED Life 148,000 hoursFlash Mode 7 selectable patterns with HIPS switchOperating Temperature -31° to 150 .8°F (-35° to 66°C)Dimensions 8" x 6 .5" (203 x 165 mm) Enclosure Rating NEMA 4XMounting: On 3/4" (19mm) NPT threaded conduitApprovals UL 1638 and cUL Listed (E11459)Weight 3 .4 lbs (1 .54 kg)Warranty 18 months

SPECIFICATIONS DIMENSIONS

8"(203mm)

6.5"(165mm)

WIRING

ACCESSORIES

BLA

CK

RE

D

24 VACWIRING

24 VACPOWER

+

GR

EE

N

GND – NEUTRAL

24 VDCWIRING

RE

D

BLA

CK

+ –

24 VDCPOWER

BLA

CK

WH

ITE

120 VACWIRING

120 VACPOWER

+

GR

EE

N

GND –NEUTRAL

Wire nuts not included.

57PLEDMR

57PLEDMB

57PLEDMA

ORDERING INFORMATION

MODEL DESCRIPTION57PLEDM LED beacon COLOR A Amber B Blue G Green M Magenta R Red W White SUPPLY VOLTAGE 24AD 12-24 VDC, 24 VAC @ 50/60 Hz 120A 120 VAC @ 50/60 Hz BASE COLOR (Blank) Gray B Black

57PLEDM G 24AD Example: 57PLEDG24AD LED beaconwith green lens, gray base, and 12-24 VDC, 24 VAC @ 50/60 Hz

CBRCorner Mount Bracket

WBRWall Mount Bracket

ACCESSORIES PAGECBR Corner Mount Bracket 70-71WBR Wall Mount Bracket 70-71

Page 9: ALARMS & INDICATION

NEW!

71

ALARMS & INDICATIONALARM

S & INDICATION

2

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014March 2014

POLARIS CLASS LED BEACON94 SERIES

DESCRIPTIONEdwards Polaris Class 94PLEDM LED beacons are NEMA Type 4X and IP66 rated visual signals designed for indoor and outdoor applications . The units are available in Edwards’ 94 Series housing in 12-24 VDC, 24 VAC, 120 VAC and are field configurable with up to seven flashing patterns, including steady-on, utilizing a “Hidden In Plain Sight” (HIPS) switch . The inner, double fresnel lens is made of a high grade polycarbonate and is designed to magnify the ultra-bright LEDs inside . A clear, outer, impact-resistant polycarbonate dome offers additional protection against accidental impacts with machinery or falling objects . It also acts as a protective and simple to clean “dust and residue” cover . The Polaris Class beacons are designed to be mounted on 3/4 inch NPT conduit (indoor or outdoor) . For outdoor installation and to maintain the NEMA and IP ratings, the beacon must be mounted with the dome facing directly up . When installing the beacon indoors in dry environments, it can be mounted in any position . The 94 Series housing has a cast base that can function as a junction box . The Polaris Class is designed for any industrial or commercial applications that require the longevity of an LED and the brightness of a xenon strobe . These units are very effective in high noise areas where ear protection is worn or audible signals may not be heard .

FEATURES• 12-24 VDC, 24 VAC, 120 VAC• Six lens colors• Seven flash patterns (includes steady-on)• Hidden in Plain Sight (HIPS) switch• 3/4" (19mm) NPT threaded conduit• High level of immunity to shock and vibration• Black or gray base option

Supply Voltage 94PLEDMx24ADx 12 VDC, 0 .7A; 24 VAC/DC, 0 .55A 94PLEDMx120Ax 120 VAC, 50/60Hz, 0 .25ALeakage Current Off State Leakage 5mASurge Current 94PLEDMx24ADx 8 .5 A / 2 ms 94PLEDMx120Ax 4 .5 A / 1 msColor Amber, blue, green, magenta, red,

white/clearProjected LED Life 148,000 hoursFlash Mode 7 Selectable Patterns with HIPS

SwitchOperating Temperature -31° to 150 .8°F (-35° to 66°C)Dimensions 94PLEDMx Models 8 .25" x 7 .75" (210 x 200 mm)Enclosure Rating NEMA 4X and IP66 RatedMounting On 3/4 inch NPT conduit

(indoor or outdoor)Approvals UL 1638 and cUL Listed (E11459)Weight 6 .10 lbs (2 .77 kg)Warranty 18 months

94PLEDMA 94PLEDMR 94PLEDMG

BLA

CK

RE

D

24 VACWIRING

24 VACPOWER

+

GR

EE

N

GND – NEUTRAL

24 VDCWIRING

RE

D

BLA

CK

+ –

24 VDCPOWER

BLA

CK

WH

ITE

120 VACWIRING

120 VACPOWER

+

GR

EE

N

GND – NEUTRAL

Wire nuts not included.

DIMENSIONS

WIRING

7.75"(200mm)

8.25"(210mm)

HIPSProgramming Switch

ORDERING INFORMATION

MODEL DESCRIPTION94PLEDM LED beacon COLOR A Amber B Blue G Green M Magenta R Red W White SUPPLY VOLTAGE 24AD 12-24 VDC, 24 VAC @ 50/60 Hz 120A 120 VAC @ 50/60 Hz BASE COLOR (Blank) Gray B Black

94PLEDM G 24AD B Example: 94PLEDG24AD LED beaconwith green lens, black base, and 12-24 VDC, 24 VAC @ 50/60 Hz

ACCESSORIES PAGECBR Corner Mount Bracket 70-71WBR Wall Mount Bracket 70-71

SPECIFICATIONS

Page 10: ALARMS & INDICATION

ALARMS & INDICATION

72

ALAR

MS &

INDI

CATI

ON

2

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014March 2014

XTRA-BRITE LED HAZARDOUS LOCATION BEACON107XBR SERIES

DESCRIPTIONThe 107XBR hazardous location XTRA-BRITE™ LED visual signals are NEMA Type 3R and Type 4 heavy-duty visual signals designed for indoor or outdoor applications . The units are available in 24 VDC or 120 VAC and are field configurable for steady-on or flashing (65 fpm) . The inner, double fresnel lens is made of a high grade polycarbonate and is designed to magnify the super-bright LEDs inside . A clear, outer, impact-resistant glass globe also covers the lens and an optional dome guard fits over the glass dome to protect it against accidental impacts with machinery or falling objects . The 107XBR has three different mounting configurations including the pendant mount, bracket mount and ceiling mount and can be mounted on 3/4" NPT threaded conduit . The 107XBR is designed for applications such as petroleum refineries, utility gas plants, dry cleaning plants, fuel servicing areas and other similar applications .

FEATURES• Available in 24VDC or 120VAC• Five lens colors• Steady-on or flashing in every unit• 3/4" NPT threaded conduit• High level of immunity to shock and vibration• Three mounting options: pendant, bracket or ceiling• UL Listed for Class I, Division 2, Groups A, B, C, D; Class II,

Division 1, Groups E, F, G; Class II, Division 2, Groups F & G and Class III, Division 1 locations

• UL and cUL Listed for Marine environments (120VAC only)

107XBRBMA

Flash Rate65 fpm

107XBRCMG

107XBRPMR

Supply Voltage 107XBRxMx24D 24 VDC 107XBRxMx120A 120 VAC, 60HzCurrent 107XBRxMx24D 220 mA 107XBRxMx120A 115 mAColor Amber,blue,green,red,clearFlash Mode Steady on or flashing

(65 FPM, field configurable)Project LED Life 148,000 hoursOperating Temperature See Table on next page Dimensions 7" X 10 .13" (178 x 260 mm)Enclosure Rating NEMA 3R and NEMA 4Mounting Bracket mount, pendant mount, ceiling mount Approvals UL & cUL Listed, UL Listed for Marine Use Weight 107XBRBMx 10 .87 lb (4 .93 kg) 107XBRCMx 9 .87 lb (4 .47 kg) 107XBRPMx 8 .97 lb (4 .06 kg)Warranty 18 months

SPECIFICATIONS

* Class II and Class III only apply to the pendant mount versions with clear globes .** Marine Rating applies to UL listing only .

Wire nuts (not supplied)Yellow,Not Connected(wire nut supplied)

Connect leads toPower Source

DC units; Red positive (+)AC units; Black HotDC units; Black negative (-)AC units; White neutral

Wire nuts (not supplied)

Connect leads toPower Source

DC units; Red positive (+)AC units; Black HotDC units; Black negative (-)AC units; White neutral

Yellow

DC units: Connectto Positive (+)AC units: Connect to Hot

(Yellow wire connectedfor Optional flash pattern)

WIRING

Page 11: ALARMS & INDICATION

NEW!

73

ALARMS & INDICATIONALARM

S & INDICATION

2

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014March 2014

XTRA-BRITE LED HAZARDOUS LOCATION BEACON107XBR SERIES

OPERATING TEMPERATURE CODES

11 3/8"(289mm)

10 1/2"(267mm)

10 7/8"(276mm)

10 1/4"(260mm)

7"(172mm)

9 7/8"(251mm)

10 1/8"(260mm)

7"(178mm)

9 3/4"(248mm)

4"(102mm)

DIMENSIONS

Pendant Mounting Bracket Mounting Ceiling Mounting

ORDERING INFORMATION

MODEL DESCRIPTION107XBR Hazardous Location LED Beacon MOUNTING PM Pendant BM Bracket CM Ceiling COLOR A Amber B Blue G Green R Red W White SUPPLY VOLTAGE 24D 24V DC 120A 120V AC @ 60 Hz

107XBR BM W 120A Example: 107XBRBMW120A Hazardous LocationLED Beacon with bracket mounting, white LED, and 120V AC @ 60 Hz

Ambient temperature

Class I, Div. 2 Groups A, B, C, D

Class II, Div. 2, Groups F, G; Class III, Div. 2

Class II, Div. 1, Groups E, F, G; Class III, Div. 1

40°C 135°C (T4) 85°C (T6)

55°C 135°C (T4) 85°C (T6)

65°C 135°C (T4) 85°C (T6)

Note: Class II and Class III only apply to the pendant mount versions with clear globes.

ACCESSORIESEDVPGU1 Optional Dome Gaurd

Page 12: ALARMS & INDICATION

ALARMS & INDICATION

74

ALAR

MS &

INDI

CATI

ON

2

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014March 2014

ORDERING INFORMATION

WIRING

105-L SeriesLens

105XBR Base

Wire nuts(not supplied)

DC units; Red Positive (+), AC units; Black Hot

18” Wire Leads

DC units; Black Negative (-), AC units; White Neutral

Power Source Wires

OFF

OFF

ON

ON

1

2

OFF

OFF

ON

ON

1

2

STEADY

65 FPM

XTRA-BRITE LED ADVERSE LOCATION VISUAL SIGNALS105XBRM SERIES

DESCRIPTIONThe 105XBRM Series LED visual signals are heavy duty, reliable, UL, cUL beacons . The 105XBRM Series features a UL listed Type 4X enclosure and is UL Listed for Marine Use . The 105XBRM Series has three different configurations for mounting that include the 105BX junction box, the 105BM mounting bracket, and the 105PM pipe mount attachment . The unit can be mounted on 3/4 NPT using the 105PM pipe attachment . It can also be surface mounted using the 105BX junction box, or wall mounted using the 105BX junction box with the 105BM mounting bracket . They can only be used with metallic wiring systems when installed at the end of the run .FEATURES• Available in 24V DC or 120V AC• Three mounting bases: 3/4" pipe mount attachment,

outlet box attachment, or wall mounting bracket• 65 fpm mode field-selectable via dipswitch• Immune to shock and vibration

105XBRMB

(Dipswitches located inside the unit)

MODEL105XBRM

105XBRM Example: 105SLEDBN5 Steady-OnLED with blue lens and light sourceand 120V 60 Hz supply voltage

B N5

DESCRIPTIONXTRA-BRITE LED Adverse Locations Visual SignalsCOLORABGRW

AmberBlueGreenRedWhiteSUPPLY VOLTAGE24D120A

24V DC120V AC

5"(127 mm)

4.5"(114 mm)

4.5"(114 mm)

5.25"(133 mm)

6"(152 mm)

2"(51 mm)

4.5"(114 mm)

2.25"(57 mm)

105PM Pipe Mount Attachment 105BM Mounting Bracket(use with 105BX)

105BX Outlet Box Attachment

MODEL Class Division Group Operating Temperature105XBRMx24D I 2 A, B, C, D T4A (120C, 248F)105XBRMx120A I I 2 F, G T4A (120C, 248F)

I I I T4A (120C, 248F)

HAZARDOUS LOCATION RATINGS

Supply Voltage 105XBRMx24D 24 VDC 105XBRMx120A 120 VAC 50/60HzCurrent Rating 105XBRMx24D 0 .215 105XBRMx120A 0 .108AColor Amber, blue, green, red, whiteFlash Mode Steady on or 65 FPM (dipswitch

settings)Projected LED Life 148,000 hoursOperating Temperature -31° to 212°F (-35° to 100°C)Dimensions 4 .75" X 3 .75" (121 x 95mm)Enclosure Rating NEMA 4XMounting ¾" pipe mount attachment, outlet

box attachment, or wall mounting bracket

Approvals UL & cUL Listed, UL Listed for Marine Use

Weight: 1 .4 lbs (0 .63 kg)Warranty: 18 months

ACCESSORIES PAGE105BM Wall-mount bracket (requires 105BX) 74,77,479-480105BX Surface-mount box 74,77,479-480105PM Pipe-mount base 74,77,479-480

SPECIFICATIONS

Page 13: ALARMS & INDICATION

NEW!

75

ALARMS & INDICATIONALARM

S & INDICATION

2

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014March 2014

XTRA-BRITE LED BEACONS125XBR SERIES

DESCRIPTIONThe Edwards 125XBR Class XBR XTRA-BRITE™ LED beacons are UL and cUL listed dual mode signaling devices, available in two versions, Steady-On/Flashing (125XBRM) and Steady-On/Lightburst (125XBRZ) . Both versions feature a corrosion resistant Type 4X enclosure and can be panel or conduit mounted . The lens is made of shatter resistant polycarbonate . Both the 125XBRM and 125XBRZ beacons are dual mode devices, maximizing application flexibility while reducing inventory costs . It can also be panel-mounted using the mounting gasket provided with the unit .

FEATURES• Available in 24 VDC or 120 VAC• Available with amber, blue, green, red or white lens• Available with gray or black base• Option for panel or conduit mounting• Available in dual mode Steady-On/Flashing LED or

Steady-On/Lightburst LED versions

Gasket (provided for use when direct panel mounting)

Locknut - 1.3625" O.D. (provided for use when direct panel mounting)

3.25"(82.6mm)

3.875"(98.4mm)

Double threaded forpanel mounting or1/2" internal or 3/4" externalconduit mounting

DIMENSIONS

Supply Voltage 125XBRxx24Dx 24 VDC 125BRxx120Ax 120 VAC,50/60HzCurrent 125XBRxx24Dx 0 .215A 125BRx120Ax 0 .108AColor Amber, blue, clear, green, redFlash Rate 125XBRM STEADY-ON/FLASHING (65 FPM) 125XBRZ STEADY-ON/LIGHTBURST (420FPM)Projected LED Life 148,000 hoursOperating Temperature -31° to 150°F (-35° to 66°C)Dimensions 3 .875"H3 .875"H(98 .4mm) X 3 .25"W

(82 .6mm)(98 .4mm) X 3 .25"W (82 .6mm)Enclosure Rating NEMA 4xMounting On 1/2" or 3/4" NPT conduit using a 1/2"

internal or 3/4" external conduit hubApprovals cULus ListedWeight 0 .5lbsWarranty 18 months

SPECIFICATIONS

ORDERING INFORMATION

125XBRZR120A Dual Mode XBR LED Beacons in NEMA 4X Enclosure, with Steady-On Lightburst, red LED, 120V AC @ 60 Hz, and gray base

MODEL DESCRIPTION125XBR Dual Mode XBR LED Beacons in NEMA 4X Enclosure OPERATION M Steady-On/ Flashing LED Z Steady-On/ Lightburst COLOR A Amber B Blue G Green R Red W White SUPPLY VOLTAGE 24D 24V DC 120A 120V AC @ 60 Hz BASE COLOR (BLANK) Gray B Black

125XBR Z R 120A Example:

125XBR

WIRING

125XBR SeriesLED Visual Indicator

Gasket(supplied)Locking Nut -

1.3625" OD(supplied)

Control panel(Enclosure)

Wire Nuts(Not Supplied)

18” Wire Leads

Power SourceWires

DC units; Red Positive (+)AC units; Black HotDC units; Black negative (-)AC units; White neutral

Yellow, Not connected (wire nut supplied) ACCESSORIES

125GRD Optional Gaurd for use with 125 Class BeaconsCBR Corner Mount BracketWBR Wall Mount Bracket

Page 14: ALARMS & INDICATION

ALARMS & INDICATION

76

ALAR

MS &

INDI

CATI

ON

2

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014March 2014

Supply Voltage 105XBRiRxA24D 24 VDC 105XBRiRxA120A 120 VAC, 50/60HzCurrent 105XBRiRxA24D 0 .15A 105XBRiRxA120A 0 .1AMax. Off State Leakage Current 5mASurge (inrush/duration) 105XBRiRxA24D 28A/65uSeconds 105XBRiRxA120A 28 .5A/212uSecondsLED Colors Red/Green/Amber or Red/Blue/AmberFlash Mode Dipswitch settings for use with or without

external controlFlash Rate XTRA-SAFE™ Mode; Red 240 FPM,

Amber120 FPM, Green or Blue 65 FPMProjected LED Life 148,000 hoursOperating Temperature 31° to 150°F (-35° to 66°C)Dimensions 4 .5"W x 4 .625"H (114 x 117 mm)Enclosure Rating NEMA 4XMounting ¾" pipe mount attachment, outlet box

attachment, or wall mounting bracketApprovals UL & cUL ListedWeight 1 .4 lb(0 .63 kg)Warranty 18 months

105XBRi-RGA

DESCRIPTIONThe Edwards 105XBRi Series XTRA-BRITE™ LED Multi-Status Indicator is a heavy duty, reliable UL and cUL listed, multi-color visual signaling device . It features a corrosion resistant Type 4X enclosure that is UL listed for Marine use, and can be panel or conduit mounted . The base is manufactured from glass-reinforced thermoplastic polyester resin and the double fresnel lens is made of shatter resistant polycarbonate . The lights are available in 24 VDC and 120 VAC 50/60 Hz, in either Red/Blue/Amber or Red/Green/Amber .

FEATURES• Available in 24V DC or 120V AC• Available in Red/Blue/Amber or Red/Green/Amber• Three mounting bases: 3/4" pipe mount attachment, outlet

box attachment, or wall mounting bracket • PLC compatible• XTRA-SAFE™ Technology enables status indication for

those who are color blind• Dip switch settings for use with or without external control• Immune to shock and vibration

XTRA-BRITE LED MULTI-STATUS INDICATOR105XBRI SERIES

SPECIFICATIONS

4.625"(92mm)

4.375"(111mm)

4.5"(114mm)

4.625"(117mm)

Cat. No Class Division Group Operating Temperature 105XBRIRGA24D l 2 A,B,C,D T5 (100°C, 212°F)105XBRIRGA120A ll 2 F,G T5 (100°C, 212°F)

lll T5 (100°C, 212°F)105XBRIRBA24D l 2 A,B,C,D T6 (85°C, 185°F)105XBRIRBA120A ll 2 F,G T6 (85°C, 185°F)

lll T6 (85°C, 185°F)

HAZARDOUS LOCATION RATINGS

DIMENSIONS

Page 15: ALARMS & INDICATION

NEW!

77

ALARMS & INDICATIONALARM

S & INDICATION

2

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014March 2014

XTRA-BRITE LED MULTI-STATUS INDICATOR105XBRI SERIES

ORDERING INFORMATION

MODEL DESCRIPTION105XBRi LED Multi-Status Indicator in NEMA 4X Enclosure COLORS RGA Red, Green, Amber RBA Red, Blue, Amber SUPPLY VOLTAGE 24D 24 VDC 120A 120 VAC @ 50/60 Hz

105XBRi RGA 24D Example: 105XBRiRGA24D LED Multi-Status Indicator in NEMA 4X Enclosure with Red, Green, and Amber lens, and 24 VDC

5"(127mm)

4.5"(114mm) 2"

(51mm) 2.25"(57mm)

5.25"(133mm)

0.34"(9mm) Diameter

(4) 3/4"Knockouts

6"(152mm)

4.5"(114mm)

4.5"(114mm)

105BM Mounting Bracket(use with 105BX)

105BXOutlet Box Attachment

105PMPipe Mount Attachment

WIRING

105-LC Lens

(2) Screws to mount105BX to themounting surface

MountingSurface

Power source wires

Wire Nuts(not supplied)

Amber (DC + or AC hot for Amber LEDactivation)

Red (DC + or AC hot forRed LED activation)

Black (DC -) or White (AC neutral)

Blue with Green tracer(DC + or AC hot for Blue or Green

LED activation (depending on model))

Applications WITHa PLC or Controller*

Applications WITHOUTa PLC or Controller* - XTRA-SAFE TechnologyDisabled

Applications WITHOUTa PLC or Controller* - XTRA-SAFE TechnologyEnabled(Factory Default)

*It is generally recommended that both dipswitches, SW1 and SW2, be set to OFF for applications using an external Programmable Logic Controller (PLC) or other external controller. A PLC or controller, how-ever, can be used with any of the shown configurations.

Dipswtich Settings:

(Dipswitch located inside the unit)

ACCESSORIES PAGE105BM Wall-mount bracket (requires 105BX) 74,77,479-480105BX Surface-mount box 74,77,479-480105PM Pipe-mount base 74,77,479-480

Page 16: ALARMS & INDICATION

ALARMS & INDICATION

78

ALAR

MS &

INDI

CATI

ON

2

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014March 2014

125XBRi

DESCRIPTIONThe Edwards 125XBRi Series XTRA-BRITE™ LED Multi-Status Indicator is a UL and cUL listed, multi-color visual signaling device . It features a corrosion resistant Type 4X enclosure and can be panel or conduit mounted . The base is manufactured from a 33% glass filled nylon, providing high resistance to heat and high chemical resistivity . The lens is made of shatter resistant polycarbonate . The lights are available in 24 VDC and 120 VAC 50/60 Hz, in either Red/Blue/Amber or Red/Green/Amber .

FEATURES• Available in 24 VDC or 120 VAC• Available with gray or black base• Available in Red/Blue/Amber or Red/Green/Amber• Option for panel or conduit mounting• PLC Compatible• XTRA-SAFE™ Technology enables status indication for

those who are color-blind• Dip switch settings for use with or without external control• Immune to shock and vibration• Protective wire guard available, Cat. No. 125GRD

Gasket (provided for use when direct panel mounting)

Locknut - 1.3625" O.D. (provided for use when direct panel mounting)

3.25"(82.6mm)

3.875"(98.4mm)

Double threaded forpanel mounting or1/2" internal or 3/4" externalconduit mounting

DIMENSIONS

XTRA-BRITE LED MULTI-STATUS INDICATOR125XBRI SERIES

Supply Voltage 125XBRiRxA24Dx 24 VDC 125XBRiRxA120Ax 120 VAC, 50/60HzCurrent 125XBRiRxA24Dx 0 .15A 125XBRiRxA120Ax 0 .1AMax. Off State Leakage Current

5 mASurge (inrush/duration) 125XBRiRxA24Dx 28 .5A/65uSeconds 125XBRiRxA120Ax 28 .5A/212uSecondsLED Colors Red/Green/Amber or Red/Blue/

AmberFlash Mode Dipswitch enabledFlash Rate XTRA-SAFE™ Mode, Red 240

FPM, Amber120 FPM, Green or Blue 65 FPM

Projected LED Life 148,000 hoursOperating Temperature -31° to 150°F (-35° to 66°C)Dimensions 3 .25"W x 3 .875"H (82 .6 x 98 .4mm)Enclosure Rating NEMA 4XMounting Conduit or panel mountApprovals UL & cUL ListedWeight 0 .5 lbs (0 .22 kg)Warranty 18 months

SPECIFICATIONS

Page 17: ALARMS & INDICATION

NEW!

79

ALARMS & INDICATIONALARM

S & INDICATION

2

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014March 2014

WIRING

Applications WITHa PLC or Controller*

Applications WITHOUTa PLC or Controller* - XTRA-SAFE TechnologyDisabled

Applications WITHOUTa PLC or Controller* - XTRA-SAFE TechnologyEnabled(Factory Default)

*It is generally recommended that both dipswitches, SW1 and SW2, be set to OFF for applications using an external Programmable Logic Controller (PLC) or other external controller. A PLC or controller, how-ever, can be used with any of the shown configurations.

Dipswtich Settings:

(Dipswitch located inside the unit)

XTRA-BRITE LED MULTI-STATUS INDICATOR125XBRI SERIES

125XBRI Series ChameleonLED Visual Indicator

Gasket(supplied)

Wire nuts(not supplied)

Locking Nut -1.3625" OD

(supplied)

Control panel

(Amber LED activation)DC Units; Amber Positive (+)AC Units; Amber Hot

(Red LED activation)(DC Units; Red positive (+)AC Units Red HotDC Units; Black DC common (-)

AC Units; White AC neutral

(Blue or Green LED activation)DC Units; Blue with green stripe, Positive (+)AC Units; Blue with green stripe, Hot

Wire color corresponds with each indicated color .Red wire = Red LED's

Yellow wire = Amber LED'sBlue with Green tracer wire = Green or Blue LED's

ORDERING INFORMATION

125XBRi-RGA-120A LED Multi-Status Indicator in NEMA 4X Enclosure, with red, green, and amber LEDs, with 120 VAC @ 60 Hz, and gray base

MODEL DESCRIPTION125XBRi LED Multi-Status Indicator in NEMA 4X Enclosure COLOR RGA Red, Green, Amber RBA Red, Blue, Amber SUPPLY VOLTAGE 24D 24 VDC 120A 120 VAC @ 60 Hz BASE COLOR (BLANK) Gray B Black

125XBRi RGA 120A Example:

ACCESSORIES PAGE125GRD Optional Guard for Use with 125 Class Beacons CBR Corner Mount Bracket 70-71WBR Wall Mount Bracket 70-71

Page 18: ALARMS & INDICATION

ALARMS & INDICATION

80

ALAR

MS &

INDI

CATI

ON

2

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

Supply Voltage Light Modules 24 VDC, 0 .065A; 24 VAC, 0 .075A to 0 .085A 120 VAC/DC, 0 .035A Piezoelectric Sound Modules 12 VAC/DC, 0 .003A; 24 VAC/DC, 0 .006mA;

48 VAC/DC, 0 .013A; 120 VAC, 0 .004A; 240 VAC, 0 .01A Magnetodynamic Sound Modules 12 VAC, 0 .12-0 .95A; 12 VDC, 0 .03-0 .335A;

24 VAC 0 .17-1 .06A; 24VDC, 0 .045-0 .45A; 120VAC, 0 .04-0 .105A; 240 VAC, 0 .025-0 .06A Color White, red,green,blue, amberFlash Mode Steady on, Single (75FPM), Double

(85FPM), Triple (85FPM)Horn Loudness Piezoelectric Sound Modules 12 VAC/DC, 72-79dB; 24 VAC/DC, 77-85dB 48 VAC/DC, 79-89dB; 120 VAC, 75-81dB 240 VAC, 78-87dB Magnetodynamic Sound Modules 12 VAC/DC, 86 .5-103 .5dB; 24 VAC/DC,

91-107dB; 120 VAC, 93-103dB; 240 VAC, 93-103 .5dB

Operating Temperature Light Modules -22° to 122°F (-30° to 50°C) Piezoelectric Sound Modules -22° to 140°F (-30° to 60°C) at 12V to 48V; -22° to 132 .8°F (-30° to 56°C) at 120V to

240V Magnetodynamic Sound Modules -22° to 140°F (-30° to 60°C) at 12V to 24V;

-22°to 122°F (-30° to 50°C) at 120V to 240VDimensions Base 1 .89"H x 2 .678" dia (48 x 68 mm) Light Module 2 .323"H x 2 .953"dia (59 x 75 mm) Sound Module 4 .095"H x 2 .953"dia (104 x 75 mm)Enclosure Rating NEMA 3R, 4X,IP66 rated base and light

modules, IP54 rated sound modulesMounting Wall mount or Surface mountWeight Base 0 .83 lb (0 .38 Kg) Light Modules 0 .81 lb (0 .37 Kg) Piezoelectric Sound Modules 1 .04 lb (0 .47 Kg) Magnetodynamic Sound Modules 1 .28 lb (0 .58 Kg)Approvals cULus Listed, CE approvedWarranty 18 months

LED STACKLIGHT200 CLASS CLEARVIEW

DESCRIPTIONThe 200 Class 70mm ClearView™ LED Stacklight™ is a versatile, multi-mode signaling device that may contain up to five light modules, or four light modules and one sounder module in a single, integrated stack . The lens modules are clear, and are available with red, amber, blue, green, yellow and white LEDs in 24 VAC, 24 VDC and 120 VAC . The lenses are made from a self-extinguishing polycarbonate material and are scratch and impact resistant . Optional piezoelectric and magnetodynamic sounder modules complement the visual signals of the Stacklight™, offering several audible tones depending on the model chosen . The sound module has been designed so that it is always in the top position of the Stacklight™ . The 200 Class 70mm ClearView™ LED Stacklight™ features an interlocking system for quick assembly without any tools . It is available in gray or black and offers multiple voltage ranges to provide solutions for industrial applications, while also meeting machine builder and OEM requirements .

FEATURES• 24 VAC, 24 VDC and 120 VAC• Stackable up to five modules including sounder• Quick and simple assembly with NO tools required• Multi-Mode (Steady, Single, Double or Triple Flash)• Two optional sounders available; Piezoelectric: Six user

selectable tones, Magnetodynamic: 32 user selectable tones• Clear lens• LED light source• Available in Gray or Black• IP65 or IP54 available• cULus Listed• CE approved

270CLED

SPECIFICATIONS

WIRING

V DC (–) (+)V AC

5

4

3

2

1

C

On the power supply line, use appropriate time-lag fuses according to the voltage.

March 2014

Page 19: ALARMS & INDICATION

NEW!

81

ALARMS & INDICATIONALARM

S & INDICATION

2

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

LED STACKLIGHT200 CLASS CLEARVIEW

MODEL DESCRIPTION270CLED LED Stacklight Module MODULE TYPE S Steady M Multimode COLOR A Amber B Blue G Green R Red Y Yellow W White SUPPLY VOLTAGE 24AD 24V AC/DC 120A 120V AC

270CLED M W 120A Example:

BASE COLOR(BLANK) GrayB Black

270CLEDMW120A LED Stacklight Module with multimode module, white LED, 120 VAC, and gray base

SOUND MODULES

DIMENSIONS/ORDERING INFORMATION

LED LIGHT MODULES

LIGHT MODULE

Ø2.953"(75mm)

2.323"(59mm)

3.11"(79mm)

Ø2.835"(72mm)

2.717"(69mm)

BASE AND COVER

.788"(20mm)

2.323"(59mm)

Ø2.678"(68mm)

1/2" NPT

Ø2.953"(75mm)

1.89"(48mm)

ACOUSTIC MODULE

4.095"(104mm)

Ø2.953"(75mm)

4.567"(116mm)

70MM PIEZOELECTRIC (PZO) ACOUSTIC MODULE DIP SWITCH SETTINGS

12 VDC/VAC 24 VDC/VAC 48 VDC/VAC 120 VAC 240 VAC

Sound Type Diagram F (Hz)1 AdB

at 1m AdB

at 1m AdB

at 1m AdB

at 1m AdB

at 1m

Continuous reduced output 50/60 0.003 75 0.006 81 0.013 83 0.004 75 0.010 81

Continuous maximum output 50/60 0.003 79 0.006 85 0.013 89 0.004 81 0.010 87

Slow intermittent reduced output 50/60 0.003 72 0.006 77 0.013 79 0.004 76 0.010 78

Slow intermittent maximum output 50/60 0.003 77 0.006 84 0.013 86 0.004 81 0.010 85

Fast intermittent reduced output 50/60 0.003 74 0.006 79 0.013 81 0.004 76 0.010 79

Fast intermittent maximum output 50/60 0.003 78 0.006 85 0.013 87 0.004 81 0.010 85

1For AC voltages only

on

21 3on

21 3on

21 3on

21 3on

21 3on

21 3

March 2014

Piezoelectric Sounder270PZO1248AD 12-48 AC/DC, Gray270PZO1248ADB 12-48 AC/DC, Black270PZO120240A 120-240 VAC, Gray 270PZO120240AB 120-240 VAC, Black

Magnetodynamic Sounder270MDA1224AD 12-24 VAC/DV, Gray 270MDA1224ADB 12-24 VAC/DV, Black270MDA120A 120 VAC, Gray270MDA120AB 120 VAC, Black270MDA240A 240 VAC, Gray270MDA240AB 240 VAC, Black **NOTE: Add B to the end of the model number for black unit.

ACCESSORIES270FLXT 270 Flexible Steel Extension Stem - 370mm270FMLADAPT 270 Female Adapter Base - Gray270JBX** Junction Box - Gray270KIT** Footing with Extension - Gray270SSXT100 270 Stainless Steel Extension Stem - 100mm270SSXT200 270 Stainless Steel Extension Stem - 200mm270SSXT400 270 Stainless Steel Extension Stem - 400mm270TEP** Threaded Extension Pole 100mm - Gray270THF** Threaded Footing - Gray270TWM** Threaded Wall Mount - Gray270TWM2** Double Threaded Wall Mount - Gray

Page 20: ALARMS & INDICATION

ALARMS & INDICATION

82

ALAR

MS &

INDI

CATI

ON

2

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

Supply Voltage 12-24 VAC/VDC, 24-240 VACVoltage Range 24 VAC/ VDC, 110 VAC, 24 VAC , 24

VDCPower Light module 5W 12-120 VAC/VDC (7W 240 VAC) Horn module 12V-2 .7 mA, 24V-6 mA, 110V-4

mA,240V-8 .5 mAColor Blue, amber,red,green, yellow, clearFlash Rate Incandescent LED 110 FPM ±20 FPM Strobe 65 FPM ±10 FPM(24 VAC/DC) 90 FPM ±20 FPM (110/240 VAC)Horn Loudness Medium, 76-86 dBOperating Temperature -22° to 140°F (-30° to 60°C)

Strobe 14° to 122°F (-10° to 50°C)Dimensions Base 2 .68"H x 2 .95" dia (6 .8 x 7 .5 cm) Light 2 .72"H x 2 .95" dia (6 .9 x 7 .5 cm) Horn 3 .11"H x 2 .95" dia (7 .9 x 7 .5 cm)Mounting Wall, two holes; surface, four holes;

2 .13" (5 .4 cm) centersEnclosure IP66 Horn IP20 upward mount Ip 24 downward mountApprovals CE UL Listed File E194312Warranty 18 months

DESCRIPTIONThe TWS Series Tower Lights enable stacking of up to five signaling devices . Each device has its own set of contacts . Starting with a bottom module, up to five devices can be added in any combination of continuous and flashing incandescent lights, continuous and flashing LED lights, and Xenon strobes . Each stack can be capped with a horn . Each light comes in a variety of colors, and all lamps are replaceable . Several wall- and pedestal-mounting configurations are available .

OPERATION• Horns• IP20 upward mount• IP24 downward moun• Ratings IP66

SPECIFICATIONS

WIRING

75 MM TOWER LIGHTSTWS SERIES

0 .5-1 .5 mm2

(22-16 AWG)

54 3 2 1

COMMON

0 .4 Nm Max .(3 .5 lb-in)

0

1

2

3

4

5

4

1

2

3

5

C

VDC(VAC)

– +

Stack withTWS-BS Stack with

TWS-BP1

Two stacks withTWS-BP2

Stack withTWS-KIT

March 2014

Page 21: ALARMS & INDICATION

NEW!

83

ALARMS & INDICATIONALARM

S & INDICATION

2

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

75 MM TOWER LIGHTSTWS SERIES

ORDERING INFORMATION

Steps Direction Part Number Description

1Select Module and Cap

(1 required)

TWS-BC Bottom module and cap

2Select

Mounting Base

(1 required)

TWS-BS Base with gasket

TWS-BP1 Single wall-mount base

TWS-BP2 Double wall-mount base

TWS-KIT Base and stem extension

3Select

Lighting Modules

(5 maximum)

Module Voltage Range

Color Continuous Incandescent

Flashing Incandescent

Continuous LED

Flashing LED

Strobe

Part Number

24 VAC BLUE TWS-F1G TWS-L1G TWS-FL1G TWS-LL1G TWS-X1G

24 VDC BLUE TWS-F1N TWS-L1N TWS-FL1N TWS-LL1N TWS-X1N

110 VAC BLUE TWS-F1A TWS-L1A TWS-FL1A TWS-LL1A TWS-X1A

24 VAC AMBER TWS-F2G TWS-L2G TWS-FL2G TWS-LL2G TWS-X2G

24 VDC AMBER TWS-F2N TWS-L2N TWS-FL2N TWS-LL2N TWS-X2N

110 VAC AMBER TWS-F2A TWS-L2A TWS-FL2A TWS-LL2A TWS-X2A

24 VAC RED TWS-F3G TWS-L3G TWS-FL3G TWS-LL3G TWS-X3G

24 VDC RED TWS-F3N TWS-L3N TWS-FL3N TWS-LL3N TWS-X3N

110 VAC RED TWS-F3A TWS-L3A TWS-FL3A TWS-LL3A TWS-X3A

24 VAC GREEN TWS-F4G TWS-L4G TWS-FL4G TWS-LL4G TWS-X4G

24 VDC GREEN TWS-F4N TWS-L4N TWS-FL4N TWS-LL4N TWS-X4N

110 VAC GREEN TWS-F4A TWS-L4A TWS-FL4A TWS-LL4A TWS-X4A

24 VAC YELLOW TWS-F5G TWS-L5G TWS-FL5G TWS-LL5G TWS-X5G

24 VDC YELLOW TWS-F5N TWS-L5N TWS-FL5N TWS-LL5N TWS-X5N

110 VAC YELLOW TWS-F5A TWS-L5A TWS-FL5A TWS-LL5A TWS-X5A

24 VAC CLEAR TWS-F6G TWS-L6G TWS-X6G

24 VDC CLEAR TWS-F6N TWS-L6N TWS-X6N

110 VAC CLEAR TWS-F6A TWS-L6A - - TWS-X6A

4 Select Horn (1 maximum)

24 VAC TWS-AG

24 VDC TWS-AN

110 VAC TWS-AA

-

- -

-

March 2014

ACCESSORIES691-K0A Control transformer, 120:24 VAC, 40 VA, Class 2DCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUTDCPA-1.2 Power supply, 120 VAC In to 24 VAC/24 VDC OutTWS-BA15D-A 110VAC Replacement IC LampTWS-BA15D-G 24 VAC Replacement IC LampTWS-BA15D-N 24 VDC Replacement IC LampTWS-LED1-A 110 VAC Blue replacement LEDTWS-LED1-G 24 VAC Blue replacement LEDTWS-LED1-N 24 VDC Blue replacement LEDTWS-LED2-A 110 VAC Amber replacement LEDTWS-LED2-G 24 VAC Amber replacement LEDTWS-LED2-N 24 VDC Amber replacement LEDTWS-LED3-A 110 VAC Red replacement LEDTWS-LED3-G 24 VAC Red replacement LEDTWS-LED3-N 24 VDC Red replacement LEDTWS-LED4-A 110 VAC Green replacement LEDTWS-LED4-G 24 VAC Green replacement LEDTWS-LED4-N 24 VDC Green replacement LEDTWS-LED5-A 110 VAC Yellow replacement LEDTWS-LED5-G 24 VAC Yellow replacement LEDTWS-LED5-N 24 VDC Yellow replacement LEDTWS-LRX2J Universal Xenon replacement- requires solder connection

Page 22: ALARMS & INDICATION

ALARMS & INDICATION

84

ALAR

MS &

INDI

CATI

ON

2

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

Supply Voltage 24 VAC, 120 VACContact Rating A600 10A, 600 VAC Q600 2 .5A, 600 VDCContact Configuration 4 Maintained or 6 Momentary

maximumMechanical Life Contact 10 million operationsContact Type Self-cleaning silver contactsContact Resistance <25 mΩOperating Temperature -13° to 158°F (-25° to 70°C)Storage Temperature -22° to 185°F (-30° to 85°C)

DimensionsM1S, M2S, M3S 4"H x 4" W x 4"D (10 .2 x 10 .2 x 10 .2 cm)

M4S 5 .91"H x 5 .91"D x 4 .72"D (15 x 15 x 12 cm)

M1F 5 .5"H x 5 .5"W x 4"D (14 x 14 x 10 .2 cm)

Enclosure Rating NEMA 1, 3R, 4, 4X, 12, 13Approvals UL Listed file # E352651, NKCR,

cULWeightM1S 2 .63 lb (1 .19 kg)M2S,M1F 2 .55 lb (1 .16 kg)M3S 2 .83 lb (1 .28 kg)M4S 3 .95 lb (1 .79 kg)Warranty 1 year

DESCRIPTIONThe ESB Series Operator Stations offer a highly visible method to shut down equipment, initiate alarms, or give a controller input during emergency conditions . Operation occurs with the breaking of a lens, and then pushing the red push-button inside . Both break-lens to release button and field replacement lens are available .

FEATURES• Highly visible yellow/black background• UL listed for Category NKCR, File #E352651• Various NEMA rated enclosures • Red push-button operators• 1 N.O. and 1 N.C. contact included

OPERATOR STATIONSESB SERIES

SPECIFICATIONS

ESB-M1F-BLR-BS

WIRING

TOP

3

4

1

2

1NO-1NCNote: Typical contact connection

(4 momentary or 6 maintained maximum)

ESB-M3S-BLP-CS

March 2014

Page 23: ALARMS & INDICATION

NEW!

85

ALARMS & INDICATIONALARM

S & INDICATION

2

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

NEW!OPERATOR STATIONS

ESB SERIES

ORDERING INFORMATION

Model Description

ESB Break-Lens Operator Station (UL NKCR)

Enclosure

M1S NEMA 1 Metal enclosure, surface mount

M3S NEMA 3R Metal enclosure, surface mount

M2S NEMA 12,13 Metal enclosure, surface mount

M4S NEMA 4,12 Metal Enclosure, surface mount

M1F NEMA 1 Metal enclosure, flush mount

Button Style

BLR “Break Lens to Release Button” model with red momentary push button

BLP “Break Lens - Push Button” model maintained operator

Legend

BS Boiler Shut-down

CS Chiller Stop

FN Exhaust Fan

HS HVAC Shut-down

PO Power Off

RP Refrigerant Purge

SD Shut Down

SO Shut Off

ST Stop

VP Ventilation Stop

VT Ventilation Start

XX* Custom Legend

ESB M1S BLP CS Example: ESB-M1S-BLP-CS Break-Lens Operator Station, NEMA 1 metal enclosure, surface mount, maintained “Break Lens Push Button” operator, labeled as “Chiller Stop”

-- -

*18 character max, no color changes, no font changes, no company logos.

ACCESSORIES PAGEES-LENS Replacment Lens for ESB series Operator Stations ES-NC Normally Closed Contact Block for Non-illuminated ESM, ESB, and ESP

Emergency Operator Stations 98ES-NO Normally Open Contact Block for Non-illuminated ESM, ESB, and ESP Operator Stations 98

March 2014

Page 24: ALARMS & INDICATION

ALARMS & INDICATION

86

ALAR

MS &

INDI

CATI

ON

2

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

Supply Voltage 24 VAC, 120 VACContact Rating A600 10A, 600 VAC Q600 2 .5A, 600 VDCContact Configuration 4 Maintained or 6 Momentary

maximumMechanical Life Contact 10 million operationsContact Type Self-cleaning silver contactsContact Resistance <25 mΩOperating Temperature -13° to 158°F (-25° to 70°C)Storage Temperature -22° to 185°F(-30° to 85°C)DimensionsM1S, M2S 4"H x 4"DW x 3"D

(10 .2 x 10 .2 x 7 .6 cm)NXS 4 .45"H x 2 .87" W x 3 .11"D

(10 .2 x 7 .6 x 7 .9 cm)SXS 3 .5"H x 3 .25"W x 2 .75"D

(8 .9 x 8 .3 x 7 .1 cm)

M3S 4"H x 4" W x 4"D (10 .2 x 10 .2 x 10 .2 cm)

M1F 5 .5"H x 5 .5"W x 3"D (14 x 14 x 7 .6 cm)

Enclosure Rating NEMA 1, 3R, 4, 4X, 12, 13 availiableApprovals UL Listed NISD File# E348889, CSA,

NEMAWeightM1S 1 .84 lb (0 .84 kg)NXS 1 .93 lb (0 .88 kg)M2S 2 .30 lb (1 .04 kg)SXS 1 .90 lb (0 .86 kg)M3S 2 .95 lb (1 .34 kg)M1F 2 .39 lb (1 .03 kg)Warranty 1 year

DESCRIPTIONThe E-Stop ESM Series Emergency Operator Stations offer a highly visible method to shut down equipment, initiate alarms, or give a controller input during emergency conditions . Operation is with the push of a red 40mm mushroom-head push-button . The button may be reset with a pull or twist of the mushroom head, depending on the button style .

FEATURES• Highly visible yellow/black background• UL listed for Category NISD Emergency Stop Devices,

File #E348889• Various NEMA rated enclosures• 40mm Red Mushroom Operators• 1 N.O. and 1 N.C. contact included

EMERGENCY OPERATOR STATIONSESM SERIES

SPECIFICATIONS

WIRING

PTI24

1 NO-1NCNote: Typical contact connection

TOP

3

4

1

2

PP0, PT0, PK

1NO-1NC Note: Typical contact connection

(4 momentary or 6 maintained maximum)

ESM-M1S-PP0-BS

ESM-NXS-PP0-VT

March 2014

Page 25: ALARMS & INDICATION

NEW!

87

ALARMS & INDICATIONALARM

S & INDICATION

2

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

EMERGENCY OPERATOR STATIONSESM SERIES

ORDERING INFORMATION

Model Description

ESM Maintained Emergency Operator Station (UL NISD)

Enclosure

M1S NEMA 1 Metal enclosure, surface mount

NXS NEMA 4X,12 Non-metal enclosure, surface mount

M2S NEMA 12,13 Metal enclosure, surface mount

SXS NEMA 4X Stainless steel enclosure, surface mount

M3S NEMA 3R Metal enclosure, surface mount

M1F NEMA 1 Metal enclosure, flush mount

Button Style

PP0 Red maintained 40mm mushroom (push-pull)

PT0 Red maintained 40mm mushroom (push-twist)

PTL24* Illuminated 24V red maintained 40mm mushroom (push-twist, lamp included)

PK0 Red maintained 40mm mushroom (push- key release)

Legend

BS Emergency - Boiler Shut-down

CS Emergency - Chiller Stop

FN Emergency - Exhaust Fan

HS Emergency- HVAC Shut-down

PO Emergency - Power Off

RP Emergency - Refrigerant Purge

SD Emergency - Shut Down

SO Emergency - Shut Off

ST Emergency - Stop

VP Emergency - Ventilation Stop

VT Emergency - Ventilation Start

XX** Custom Legend

ESM M1S PP0 CS Example: ESM-M1S-PP0-CS Maintained Emergency Operator Station, NEMA1 metal enclosure, surface mount, Red maintained 40mm push-pull mushroom, labeled as “Chiller Stop”

- - -

*Can only be used with M1S or M1F enclosure**18 character max, no color changes, no font changes, no company logos.

March 2014

ACCESSORIES PAGEES-KEY Replacement Key for PK0 option, ESM and ESP series 87,89ES-NC Normally Closed Contact Block for Non-illuminated ESM, ESB, and ESP Emergency Operator Stations 85,87,89ES-NO Normally Open Contact Block for Non-illuminated ESM, ESB, and ESP Emergency Operator Stations 85,87,89

Page 26: ALARMS & INDICATION

ALARMS & INDICATION

88

ALAR

MS &

INDI

CATI

ON

2

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

Supply Voltage 24 VAC, 120 VACContact Rating A600 10A, 600 VAC Q600 2 .5A, 600 VDCContact Configuration 4 Maintained or 6 Momentary

maximumMechanical Life Contact 10 million operationsContact Type Self-cleaning silver contactsContact Resistance <25 milli ohmsOperating Temperature -13° to 158°F (-25° to 70°C)

Storage Temperature -22° to 185°F (-30° to 85°C)Dimensions 4 .5"H x 2 .75"W x 0 .63"D

(11 .4 x 7 x 1 .6 cm)Enclosure Rating NEMA 1, 3R, 4, 4X, 12, 13Approvals UL Listed NISD File# E348889Weight 0 .58 lb (0 .26kg)Warranty 1 year

DESCRIPTIONThe E-Stop ESP Series Emergency Operator Stations offer a highly visible method to shut down equipment, initiate alarms, or give a controller input during emergency conditions . The ESP Series consists of a stainless steel plate with a 40mm mushroom head push-button . The button may be reset with a pull or twist of the mushroom head, depending on the button style .

FEATURES• Stainless steel plate mounted• Highly visible yellow/black background• UL listed for Category NISD Emergency Stop Devices,

File #E348889• 40mm Red Mushroom Operators• 1 N.O. and 1 N.C. contact included

EMERGENCY OPERATOR STATIONSESP SERIES

SPECIFICATIONS

WIRING

PTI24

1 NO-1NCNote: Typical contact connection

TOP

3

4

1

2

PP0, PT0, PK

ESP-PK0-SO

ESP-PP0-HS

1NO-1NCNote: Typical contact connection

(4 momentary or 6 maintained maximum)

March 2014

Page 27: ALARMS & INDICATION

NEW!

89

ALARMS & INDICATIONALARM

S & INDICATION

2

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

ORDERING INFORMATION

EMERGENCY OPERATOR STATIONSESP SERIES

Model Description

ESP Plate-mounted Emergency Operator Station (UL NISD)

Button Style

PP0 Red maintained 40mm mushroom (push-pull)

PT0 Red maintained 40mm mushroom (push-twist)

PTL24 Illuminated 24V Red maintained 40mm mushroom (push-twist, lamp included)

PK0 Red maintained 40mm mushroom (push- key release)

Legend

BS Emergency - Boiler Shut-down

CS Emergency - Chiller Stop

FN Emergency - Exhaust Fan

HS Emergency- HVAC Shut-down

PO Emergency - Power Off

RP Emergency - Refrigerant Purge

SD Emergency - Shut Down

SO Emergency - Shut Off

ST Emergency - Stop

VP Emergency - Ventilation Stop

VT Emergency - Ventilation Start

XX* Custom Legend

ESP PP0 CS Example: ESP-PP0-CS Plate mounted Emergency Operator Station. Red Maintained Push-Pull button labeled as “Chiller Stop”.

- -

*18 character max, no color changes, no font changes, no company logos.

ACCESSORIES PAGEES-KEY Replacement Key for PK0 option, ESM and ESP series 98ES-NC Normally Closed Contact Block for Non-illuminated ESM, ESB, and ESP Emergency Operator Stations 98ES-NO Normally Open Contact Block for Non-illuminated ESM, ESB, and ESP Emergency Operator Stations 98

March 2014

Page 28: ALARMS & INDICATION

ALARMS & INDICATION

90

ALAR

MS &

INDI

CATI

ON

2

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

OPERATOR STATIONSST120 SERIES

ORDERING INFORMATION

ACCESSORIES PAGEPILCLHCOV1 Clear hinged cover for push-pull model and ST120SN4XNM 90,92PILCLHCOV5 Clear hinged cover for break-lens model except ST120SN4XNM PILENS Replacement lens for break-lens model PILNCCB N.C. stackable contact block for MST1 stations 90-92PILNOCB N.O. stackable contact block for MST1 Stations 90-92

- Red maintained 40 mm mushroom (push-pull) labeled “Pull to Reset” NEMA 4X and 12 nonmetallic surface-mount boxF Red maintained 40 mm mushroom (push-pull) labeled “Pull to Reset” NEMA 4 and 12 all-metal flush-mount boxFN1 Red maintained 40 mm mushroom (push-pull) labeled “Pull to Reset” NEMA 1 all-metal flush-mount boxN1 Red maintained 40 mm mushroom (push-pull) labeled “Pull to Reset” NEMA 1 all-metal surface-mount boxRP1 Red “Raised Lid - Push Button” padlockable solid lid over momentary flush round push buttonRP2 Red “Raised Lid - Push Button” padlockable solid lid over maintained flush round push button

LEGENDSBS EMERGENCY - BOILER SHUT-DOWNCS EMERGENCY - CHILLER STOPFAN EMERGENCY - EXHAUST FANHS EMERGENCY - HVAC SHUT-DOWNPO EMERGENCY - POWER OFFRPG EMERGENCY - REFRIGERANT PURGESD EMERGENCY - SHUT DOWNSO EMERGENCY - SHUT OFFST EMERGENCY - STOPVS EMERGENCY - VENTILATION STOPVSTART EMERGENCY - VENTILATION START

PUSH-BUTTON OPERATION

MODEL DESCRIPTIONST120 Complete break-lens emergency operator station (spare lens included, contacts not included)

FN1 NEMA 1 all-metal flush-mount boxFN4 NEMA 4 and 12 all-metal flush-mount boxSN1 NEMA 1 all-metal surface-mount boxSN3R NEMA 3R rainproof all-metal surface-mount boxSN4 NEMA 4 and 12 all-metal surface-mount boxSN4XNM NEMA 4X non-metalic surface-mount box

- Red “Break Lens to Release Button” model (use normally closed contact to close circuit when button releases)BP1 Red “Break Lens - Push Button” model, momentary operatorBP2 Red “Break Lens - Push Button” model, maintained operatorP1 “Break Lens - Operate Switch” two-position selector switch, maintained both positions, short leverP3 “Break Lens - Operate Switch” three-position selector switch, maintained all positions, short lever

BREAK-LENS OPERATION

LEGENDS - See above

MODEL DESCRIPTIONST120SL Complete push-pull emergency operator station (contacts not included)

Notes: Six contact blocks max (2 rows of 3) may be used on each break glass operator station and the -FN1 and -N1 modesl of push-button operation stations . The - model and F model push-button stations can only take three contact blocks (1 row of 3) . All units use normally open contacts to close circuit or normally closed to open circuit (except "Break Glass of Release Button" model) .

ST120-SN3R-BP2-CS ST120SL-N1-BSST120-FN1-BP2-RPG ST120SL-RP2-VSST120-SN4XNM-PO

March 2014

PillaElectricalProducts, Inc.

DESCRIPTIONST120 Series Operator Stations offers a means of disconnect to shut down equipment and/or initiate alarms during emergency conditions . Contacts are rated 600V @ 10A AC and 2 .5A DC . All models carry a one-year warranty . UL file is E158147 .

Page 29: ALARMS & INDICATION

NEW!

91

ALARMS & INDICATIONALARM

S & INDICATION

2

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

NEW!DESCRIPTIONThe WPS Series Plate-mounted Operator Stations mount on a single-gang wall box or a standard handy box and come with brushed stainless steel plate . They are rated NEMA 1 for indoor applications . Many options are available for the WPS Series in addition to the models shown on our catalog page .

FEATURES• Mounted on brushed stainless steel wall plate• Order contacts separately for wiring flexibility• Hinged lockout lids options• Special configurations and labeling are available• Single-gang wall or handy box mounting• Contacts rated 600V at 10A AC and 2.5A DC• One-year warranty• UL File E158147

PLATE MOUNTED OPERATOR STATIONSWPS SERIES

ORDERING INFORMATION

MODEL DESCRIPTION WPS Wall plate, box mounted emergency operator station (order contacts separately)

BUTTON STYLE MO Red momentary 40 mm mushroomMP Red maintained 40 mm mushroom (push-pull) labeled “Pull to Reset”TW Red maintained 40 mm mushroom (push-turn to reset) labeled “Turn to Reset”KR Red maintained key release 40 mm mushroom with two keys, key required to reset onlyRP1 Red “Raise Lid - Push Button” padlockable solid lid over momentary flush round push buttonRP2 Red “Raise Lid - Push Button” padlockable solid lid over maintained flush round push buttonCP1 Red “Raise Lid - Push Button” padlockable clear lid over momentary flush round push buttonCP2 Red “Raise Lid - Push Button” padlockable clear lid over maintained flush round push buttonBR Break Lens model with hammer (NC/NO contacts included)

LEGENDS CS EMERGENCY - CHILLER STOP PO EMERGENCY - POWER OFF BS EMERGENCY - BOILER SHUT-DOWN HS EMERGENCY - HVAC SHUT-DOWN VS EMERGENCY - VENTILATION STOP ST EMERGENCY - STOP SD EMERGENCY - SHUT-DOWNVSTART EMERGENCY - VENTILATION START SO EMERGENCY - SHUT-OFF CLM Clearhinged lockout lid for use with MO, MP, TW, KR 40mm mushroom button DLM Hinged lockout lid for use with MO 40mm mushroom button. Requires lid to be lifted in order to automatically release/extend mushroom device.

WPS MP VSTART

Example: WPS-MP-VSTART Wall plate operator station red maintained push-pull button labeled “Ventilation Start”

WPS-KR-VS WPS-BR-POWPS-MP-BS-CLM

WPS-RP2-HSWPS-MO-PO-DLM

RELATED PRODUCTS PAGEPILCLM Clear cover for MO, MP, TW, KR stations PILNCCB N.C. stackable contact block 103PILNOCB N.O. stackable contact block 103PILRPKEY Replacement key for WPS-KR series, specify model and key number when ordering PILBRLENS Replacement lenses for WPSBR models only (3/pkg)

Note: Three contact blocks can be used for a depth of 1-5/8" (42 mm) .Three more can be added for a depth of 2-5/8" (67 mm) .

March 2014

PillaElectricalProducts, Inc.

Page 30: ALARMS & INDICATION

ALARMS & INDICATION

92

ALAR

MS &

INDI

CATI

ON

2

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

ORDERING INFORMATION

POWER CONTROL STATIONSMNST AND MST1 SERIES

DESCRIPTIONThe MNST and MST1 Series Power Control Stations offer two push-button control for a variety of HVAC and other equipment . It comes with two round push-buttons (one green and one red) and one set of normally open and normally closed contacts .

FEATURES• Models with non-metallic NEMA 4X & 12 enclosures for

outdoor and wet locations• Models with metal NEMA 1 enclosures for indoor and dry

locations• Bold, reflective legends on white enamel aluminum face

plate• Two maintained/interlocked push buttons on MNST models• Two momentary/non-interlocked ormomentary/

noninterloced, push buttons on MST1 models• UL listed, File E158147

Contact Rating 600V, 10A continuous @120 VAC, 0 .5A continuous @24 VDC

Contact Configuration 1NC, 1 NOOperating Temperature -13° to 158°F (-25° to 70°C)Storage Temperature -40° to 158°F (-40° to 70°C)Conduit Connection MNSTxxN1x/MST1xxN1x Knockouts in top, bottom & back for 1/2"

(1 .27 cm) and 3/4" conduitMounting MNSTx/MST1x Surface mount, external mounting tabs

top and bottom MNSTxxN1x/MST1xxN1x Surface mount, two mounting holes in the

back

Approvals UL Listed file #E158147, cUL ListedEnclosure Rating MNSTx/MST1x NEMA 4X/4/12/3/1, Nonmetallic backbox MNSTxxN1x/MST1xxN1x NEMA 1, Metal backboxDimensions MNSTx/MST1x 4"W x 4"H x 2 .4"D

(10 .16 x 10 .16 x 6 .09 cm) MNSTxxN1x/MST1xxN1x 4"W x 4"H x 3"D

(10 .16 x 10 .16 x 7 .62 cm)Weight MNSTx/MST1x 1 lb (0 .45 kg) MNSTxxN1x/MST1xxN1x 2 .5 lbs (1 .13 kg)Warranty 1 year

SPECIFICATIONS

MNSTN1SS withPILCLHCOV1 COVER

MNSTLGSS

PillaElectricalProducts, Inc.

ACCESSORIESPILNCMN Additional specialty normally closed contact block for MNST stations onlyPILNOMN Additional specialty normally open contact block for MNST stations onlyPILCLHCOV1PILNCCBPILNOCB

Clear hinged cover, tamperproofN.C. stackable contact block for MST1 stationsN.O. stackable contact block for MST1 stations

ModelMNST

MNST

(BLANK)LB

LB

LCLELFLGLHLPLV

(BLANK)N1

N1

SS

SS

OOCI

Example: MNSTLBN1SS Boiler control station in NEMA 1 metal housing with start and stop pushbuttons

DescriptionPower control stations, two maintained/interlocked pushbuttons, one set of NO/NC specialty contact blocks included

MST1 Power control stations, two momentary/non-interlocked pushbuttons, one set of NO/NC contact blocks included

Main legend "HVAC"Main legend "POWER"Main legend "VENTILATION"

Default main legend "POWER CONTROL SWITCH"Main legend "BOILER"Main legend "CHILLER"Main legend "EXHAUST FAN"Main legend "FUEL"Main legend "GENERATOR"

Custom inscriptions on pushbuttons (customer to provide inscription details)

NEMA 4X/4/12/3 non-metallic grey surface-mount box for outdoor or indoor/wet locationsNEMA 1 metal grey surface-mount box for indoor/dry locations

"START" and "STOP" pushbuttons"ON" and "OFF" pushbuttons

March 2014

ACCESSORIES PAGEPILCLHCOV1 Clear hinged cover for push-pull model and ST120SN4XNM 90,92PILNCCB N.C. stackable contact block for MST1 stations 90-92PILNCMN Additional specialty Normally Closed contact block for MNST stations only PILNOCB N.O. stackable contact block for MST1 Stations 90-92PILNOMN Additional specialty Normally Open contact block for MNST stations only

Page 31: ALARMS & INDICATION

NEW!

93

ALARMS & INDICATIONALARM

S & INDICATION

2

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014March 2014

Supply Voltage Black 24 VDC @ 10 mA Color 24 VDC @ 35 mAInput Signal 0-5 VDC or 0-10 VDCInput Impedance 400 kΩAccuracy 0 .1% of scale plus one digitDigit Count VPI-1, VPI-4 3-1/2 digits VPI-3 4-1/2 digitsDigit Size VPI-1, VPI-3C 0 .5" (1 .27 cm) VPI-4 1 .0" (2 .54 cm)Digit Span (VPI-3) 2000 digits (20000 digits)Decimal Point (VPI-3) Three positions or none, Four positions or noneDisplay Color Black, amber, green, redZero Range (VPI-3) -1999 to 1999, -19999 to 19999Operating Humidity 95% non-condensingOperating Temperature 32° to 122°F (0° to 50°C)Panel Clearance 1 .0" (5 .08 cm)Cutout Requirement VPI-1C 1 .00"H x 2 .40"W (2 .54 x 6 .10 cm) VPI-4 1 .77"H x 3 .62"W (4 .5 x 9 .2 cm)Dimensions VPI-1C, VPI-3C 1 .10"H x 2 .51"W (2 .82 x 6 .38 cm) VPI-4 1 .89"H x 3 .62"W (4 .8 x 9 .6 cm) E (NEMA4X) 6 .0"H x 6 .0"W x 3"D (15 .2 x 15 .2 x 7 .6 cm) WMB 2 .12"H x 3 .12"W x 1 .75"D (5 .4 x 7 .94 x 4 .45 cm)Enclosure Rating NEMA 1, NEMA 4XApprovals RoHSWeight 4 oz (113g)Warranty 1 year

3-1/2 DIGIT LCD PANEL DISPLAYVPI SERIES

DESCRIPTIONThe VPI Series is a voltage (0-5V, 0-10V) input 24 VDC powered, 3-1/2 digit display . The VPI Series uses a voltage signal of 0-5 or 0-10 VDC that can be scaled to a span of 2000 digits within a range of -1999 to 1999 . This display also features jumper selectable, built-in engineering units . The VPI-4 offers large, easy to read 1" (2 .54 cm) digits .

FEATURES

• 0-5 or 0-10 VDC input signal• 3-1/2 digit, easy to read LCD display (VPI-1, VPI-4)• 4-1/2 digit, easy to read LCD display (VPI-3)• Available in black amber, green and red digits• Snap-in panel mounting• NEMA 4 enclosure available• Precalibrated before shipping• Positive-to-negative indication• Jumper selectable engineering unit display of °F, °C, PSI, %

Power supply24 VDC

+ - + - + -

Voltageinput

* PWR- and SIG- must be externally connected together

PWR SIG BL

VPI

Power connection onlyrequired for amber, green,or red display.

5V

10V

OFFSET

5V Span pot

10V Span pot

Offset (ZERO) pot

WIRING

SPECIFICATIONS

ORDERING INFORMATION

VPI-1C A E-DBL Example: VPI-1C-A-E-DBL Two amber 3-1/2 digit displays mounted in a single enclosure

MODEL DESCRIPTIONVPI-4 3-1/2 digit panel display*, 1'' (2.54 cm) digitsVPI-1C 3-1/2 digit panel display*, 0.5'' (1.27 cm) digitsVPI-3C 4-1/2 digit panel display*, 0.5'' (1.27 cm) digits – 3-1/2 digit display with black digits A 3-1/2 digit display with amber digits G 3-1/2 digit display with green digits R 3-1/2 digit display with red digits – No enclosure E LCD panel display with NEMA 4X enclosure (VPI-1C and VPI-3C only) WMB LCD panel display with small enclosure (VPI-1C and VPI-3C only) E-DBL Two LCD panel displays in one NEMA 4X enclosure (VPI-1C and VPI-3C only)

VPI-1-C-WMB

VPI-4

VPI-1-C-G(typical panel mount)

VPI-1-C-R-E VPI-1-C-R-E-DBLAPPLICATION• Temperature• Humidity• Pressure

• Gallons per minute• Voltage• Kilowatt demand

Displays are custom calibrated at no charge and require specification of input scale (VDC), range, engineering units, and decimal point placement .

RELATED PRODUCTS PAGEDCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUT 995DCPA-1.2 Power supply, 120 VAC In to 24 VAC/24 VDC OutGP-3420 LPI-1C, LPI-3C, VPI-1C mounting goof plate, 3.40" x 2.00" (8.6 x 5.1 cm) 93,97-99GP-3430 LPI-1C, LPI-3C, VPI-1C mounting goof plate, 3.40" x 3.00" (8.6 x 7.6 cm) 93,97-99

Page 32: ALARMS & INDICATION

ALARMS & INDICATION

94

ALAR

MS &

INDI

CATI

ON

2

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014March 2014

Supply Voltage 4 to 30 VDC @ 35 mA Input Signal 0/2-10 VDC, 4-20mA (with resistor)

0-40 VDC maxInput Impedance 110 mA @ 5 VDCWire Type Screw terminals, 16 to 26 AWGAccuracy 0 .05% typical, 0 .1% maximumDisplay Type SGD-24 2 .4 inch diagonal 320 x 240 pixels,

16-bit color SGD-28 2 .8 inch diagonal 320 x 240 pixels,

16-bit colorInterface Compatible with Windows XP, 2000,

Vista, Windows 7, mini USB cable connection

Sample Intervals 3 samples per secondOperating Temperature 32° to 104°F (0° to 40°C)Panel Cutout SGD-24 1 .81"H x 2 .91"W (4 .60 x 7 .40 cm) 0 .11"

(3 mm) maximum panel thickness SGD-28 2 .15"H x 3 .43"W (5 .45 x 8 .70 cm)

0 .11" (3 mm) maximum panel thicknessDimensions SGD-24 1 .9"H x 3 .0"W x 0 .7"D

(4 .8 x 7 .6 x 1 .8 cm) SGD-28 2 .2"H x 3 .5"W x 0 .8"D

(5 .7 x 8 .9 x 1 .9 cm) NEMA 4X enclosure 6 .0"H x 6 .0"W x 3 .0"D

(15 .2 x 15 .2 x 7 .6 cm)Enclosure Options NEMA 1 standard NEMA 4X optional Additional Specifications Meter choices- Bar graph, analog

needle, digital readout, combinationsApprovals CE, RoHSWeight SGD-24 0 .11 lb (0 .05 kg) SGD-28 0 .14 lb (0 .06 kg)Warranty 1 year

PANELPILOT SMART GRAPHICAL DISPLAYSGD-24, -28

DESCRIPTIONThe PanelPilot Smart Graphics Display is a configurable panel-mount volt meter with selectable graph colors, input signal scales, and meter display types . It can be used to display any proportional control or transmitter signal represented by a voltage span within 0 to 40 VDC . It is easily and quickly field-configured using simple software, via a USB cable, or is available preconfigured from Kele . It has a customizable splash screen and comes in a 2 .4" or 2 .8" screen size . A NEMA 4X enclosure is also available which can house one or two displays, preassembled at Kele or separately available for field installation .

FEATURES• 2.4" or 2.8" color TFT screen for high visibility• Free PanelPilot software saves money• Simple USB cable connection for quick setup• 6 standard meter types, selectable colors, scales, and

labels for display flexibility• Splash screen accepts common picture files and

allows customization• Snap-in panel mount for fast installation• NEMA 4X enclosure option with single or double

display mounting

APPLICATION• Temperature• Humidity• Pressure• Air quality• Valve or damper position• Air or water flow• Water level• Light level• Motor speed• Any 4-20 mA or 0-10 VDC transmitter signal

SPECIFICATIONS

SGD-28-M-C-E

METER CHOICES

SGD-28-M

Digital Analog Analog & Digital Bar Graph Bar Graph Meter Digital & Bar Graph Meter

Page 33: ALARMS & INDICATION

NEW!

95

ALARMS & INDICATIONALARM

S & INDICATION

2

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

WIRING

PANELPILOT SMART GRAPHICAL DISPLAYSGD-24, -28

24 VDCPower Supply

1-5 V

BAS Input 4-20 mA + -

+

+

-

+ -

4-20 mALoop-powered

Transmitter

-

+

4-20 mA Wiring

1

1 = IN2 Input 2 (40 VDC max) (not used)2 = IN1 Input 1 (40 VDC max)3 = OV Common4 = v+ Power (4-30 VDC)

+2 3 4

- *24 VDC POWER SUPPLY MUST BE FLOATING (NOT GROUNDED TO

BAS COMMON)*

250Ω*

*Order Separately

*Meter must be configured for 1-5 V input for 4-20 mA input signal, when

using the 250Ω resistor. If using a 500Ω resistor, configure the meter for 2-10 V.

24 VDCPower Supply

BAS Input 0-10V

-

+

-

+ -

0-10 VDCTransmitter+

-+

0-10 VDC Wiring

+1 2 3 4

+

+

- SIGPWR

-

ORDERING INFORMATION

ACCESSORIESSFP66-258E Panel for SGD-24, singleSFP66-258F Panel for SGD-24, doubleSFP66-258C Panel for SGD-28, singleSFP66-258D Panel for SGD-28, doubleUSB-A-MF USB Cable Type A TO Mini BP6063C-P258 6x6x3 NEMA4X Encl Clear Hinge Cover w/ SOPK Kit250R-3-1 250 OHM 3 WATT 1% Resistor Long Leads

MODEL DESCRIPTIONSGD-24-M Smart Graphics Display, 2.4 inchSGD-24-M-C Smart Graphics Display, 2.4 inch, custom calibratedSGD-24-M-C-E Smart Graphics Display, 2.4 inch, calibrated, enclosureSGD-24-M-C-XK Smart Display, 2.4 inch, calibrated, custom graphicSGD-24-M-C-XK-E Smart Display, 2.4 inch, calibrated, custom graphic, enclosureSGD-24-M-CEDBL Smart Display, 2.4 inch, calibrated, enclosure, doubleSGD-24-MCXKEDBL Smart Display, 2.4 inch, calibrated, custom graphic, enclosure, doubleSGD-28-M Smart Graphics Display, 2.8 inchSGD-28-M-C Smart Graphics Display, 2.8 inch, custom calibratedSGD-28-M-C-E Smart Graphics Display, 2.8 inch, calibrated, enclosureSGD-28-M-C-XK Smart Display, 2.8 inch, calibrated, custom graphicSGD-28-M-C-XK-E Smart Display, 2.8 inch, calibrated, custom graphic, enclosureSGD-28-M-CEDBL Smart Display, 2.8 inch, calibrated, enclosure, doubleSGD-28-MCXKEDBL Smart Display, 2.8 inch, calibrated, custom graphic, enclosure, double

Note: Custom Calibrated Panels, require completion of the panel configuration worksheet . Work-sheet available on Kele website www .kele .com

RELATED PRODUCTSDCPA-1.2 Power supply, 120 VAC IN to 24 VAC/24 VDC OUTDCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUT

March 2014

Page 34: ALARMS & INDICATION

ALARMS & INDICATION

96

ALAR

MS &

INDI

CATI

ON

2

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014March 2014

Supply Voltage 90-240 VAC, 12 VA / 10 .5 - 30 VAC/VDC 6VAInput Current 4-20 mA, 300ΩInput Voltage DC 0-5 VDC, 0-10 VDC, 1 MΩInput Monitor DC power (no offset, 10 MΩ 0-200 mVDC,

0-2 VDC, 0-20 VDCAccuracy ±1% full scale plus 1 count Digit Span 3-1/2 digitDecimal Point Off, DP1, DP2, DP3

(1999, 199 .9, 19 .99, 1 .999)Display Color Red, green, blueDisplay Size 2 .3" (5 .8 cm)Display Type Seven-segment LEDRange -1999 to 1999Calibration Zero and span, non-interactiveOperating Humidity 5-95% RH non-condensingOperating Temperature 14° to 122°F (-10° to 50°C)Cutout Requirement 4 .0"H x 10 .4"W x 2 .0"D (10 .0 x 26 .4 x 5 .0 cm)Dimensions 4 .2"H x 10 .6"W x 2 .2"D (10 .6 x 27 .0 x 5 .5 cm)Enclosure Options NEMA 1, aluminum and plasticMounting Panel: Steel U-bracket Wall/ceiling: Steel swivel bracketApprovals RoHSWeight 2 .8 lb (1 .3 kg)Warranty 1 year

KELE BIG DISPLAY READOUT, 3-1/2 DIGIT LED, RED/BLUE/GREENBDR SERIES

DESCRIPTIONThe BDR Big Display Readout has large 2 .3" size LED digits . It provides 3-1/2 digits and comes in three bright LED colors: red, green or blue . The BDR has a selectable decimal point position and accommodates negative sign readouts . The readouts are in linear proportion to the 4-20 mA, 0-10 VDC, 0-5VDC signal inputs or a voltage monitor input from 0-20VDC . These displays are easy to field calibrate with non-interactive zero and span pots as well as free pre-calibration service from Kele at time of order .

FEATURES• Large 2.3" (5.8 cm) digital display• LED colors in red, green or blue• 3-1/2 digit with negative signal as needed• Standard signal inputs: 4-20 mA, 0-10 VDC, 0-5 VDC• Wall, ceiling or panel mount• Non-interactive zero and span pots• Pre-calibration

Calibration pots(use varies withsource; seeinstallationmanual)

SPAN

IN– IN+DCV

Power supply monitor0-(0.2, 2, or 20) VDC

Voltage signal in

LPI = Current signalVPI = Voltage signalDCV = Voltage monitorDP = Decimal point placementLPI OFFSET = Negative (–) sign Choice for V or I signal

*LPI function disables RANGES switch

0-5 or 0-10 VDC

Current signal in4-20 mA

VPI

VPI

DCV

RANGES

200m

V20

0mV

2V5V

20V

10V

INPUT

LPIAC POWER90V-250V

SIG– SIG+ SIG– SIG+ AC GNDAC

DCV 5V 10VLPIVPI LPI

OFFSET

FUNCTION DECIMAL

LPI

VPIDCV

DP1

DP2DP3

+

*

*

–SPAN SPANSPAN

SPAN OR ZERO ADJ.

ZERO ZERO

BDR-999-[R/G/B]-2410.5 to 30 VAC/VDC

WIRING

SPECIFICATIONS

BDR-G

BDR-B

Mounting Brackets included

ORDERING INFORMATION

MODEL DESCRIPTIONBDR-999-R-24 Red LED 3-1/2 digit display, 2.3" (5.8 cm) high 24 VAC/VDCBDR-999-G-24 Green LED 3-1/2 digit display, 2.3" (5.8 cm) high 24 VAC/VDCBDR-999-B-24 Blue LED 3-1/2 digit display, 2.3" (5.8 cm) high 24 VAC/VDCBDR-999-R-120 Red LED 3-1/2 digit display, 2.3" (5.8 cm) high 120 VACBDR-999-G-120 Green LED 3-1/2 digit display, 2.3" (5.8 cm) high 120 VACBDR-999-B-120 Blue LED 3-1/2 digit display, 2.3" (5.8 cm) high 120 VAC

Displays are custom calibrated at no charge and require specification of input scale (mA, VDC), range, engineering units, and decimal point placement .

BDR-R

RELATED PRODUCTSDCPA-1.2 Power supply, 120 VAC IN to 24 VAC/24 VDC OUTDCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUT

Page 35: ALARMS & INDICATION

NEW!

97

ALARMS & INDICATIONALARM

S & INDICATION

2

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014March 2014

DESCRIPTIONModel LPI-1C is a loop-powered indicator featuring a large 3-1/2 digit LCD display with black digits . The Model LPI-1C displays engineering units of °F, °C, PSI, %, or no engineering units if desired . It is directly powered by the 4-20 mA signal and scaled to specifications .

FEATURES• Indication of 4-20 mA signal in desired scale• 3-1/2 digit LCD display• Snap-in panel mounting• Easy-to-read digits• NEMA 4X enclosure available• Precalibrated for desired range• Negative-to-positive indication• Jumper-selectable engineering unit display

Powersupply

Sensor/transmitter

BAS inputor other

4-20 mA load

-

+ -

+

ZERO

SPAN

+ -Factory calibrated(no field calibration

needed)

- +

Back of display unit

Board unit°F°CPSI%

Connector pins Engineering unit jumpersUnit selected displays tothe right of display reading.

4-20 mA

SIGConnect the LPI-1C indicator in series with the 4-20 mA current loop to be measured.

WIRING

APPLICATION• Temperature• Humidity• Pressure• Differential or static pressure• Kilowatt demand

3-1/2 DIGIT LCD PANEL DISPLAYLPI-1C

SPECIFICATIONS

ORDERING INFORMATION

LPI-1C E-DBL Example: LPI-1C-E-DBL Two LPI-1C displays mounted in a single enclosure

MODEL DESCRIPTIONLPI-1C 3-1/2 digit LCD panel display with black digits* – No enclosure E 3-1/2 digit LCD panel display with NEMA 4X enclosure WMB 3-1/2 digit LCD panel display with small enclosure E-DBL Two 3-1/2 digit LCD panel displays in one NEMA 4X enclosure

• Gallons per minute• Voltage• Current• Many other 4-20 mA applications

LPI-1C-WMB

Input Signal 4-20 mA loop-poweredInput Impedance 300Ω nominal @ 24 VDCAccuracy 0 .1% of scaleDigit Size 0 .5" (1 .27 cm)Decimal Point Three positions or none (1 .0 .0 .0)Display Color BlackRange -1999 to 1999Operating Humidity 95% non-condensingOperating Temperature 32° to 122°F (0° to 50°C)Panel Clearance 1 .97" (5 .00 cm)Cutout Requirement 1 .00" H x 2 .40" W (2 .54 x 6 .10 cm)Dimensions Display 1 .11" H x 2 .51" W (2 .82 x 6 .38 cm) E (NEMA 4X) 6 .0"H x 6 .0"W x 3 .0"D

(15 .2 x 15 .2 x 7 .62 cm) WMB 2 .12''H x 3 .12''W x 1 .75''D

(5 .4 x 7 .94 x 4 .45 cm)Approvals RoHSWeight 0 .14 lb (0 .06 kg) (display only)Warranty 1 year

LPI-1C (typical panel mount)

LPI-1C-E LPI-1C-E-DBL

Displays are custom calibrated at no charge and require specification of input scale (mA), range, engineering units, and decimal point placement .

RELATED PRODUCTS PAGEDCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUT DCPA-1.2 Power supply, 120 VAC In to 24 VAC/24 VDC Out GP-3420 LPI-1C, LPI-3C, VPI-1C mounting goof plate, 3.40" x 2.00" (8.6 x 5.1 cm) 93,97-99GP-3430 LPI-1C, LPI-3C, VPI-1C mounting goof plate, 3.40" x 3.00" (8.6 x 7.6 cm) 93,97-99

Page 36: ALARMS & INDICATION

ALARMS & INDICATION

98

ALAR

MS &

INDI

CATI

ON

2

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

NEW!

March 2014

Supply Voltage 24 VDC @ 35 mAInput Signal 4-20 mA loop poweredInput Impedance 300Ω nominal @ 24 VDCAccuracy 0 .1% of scaleDigit Size 0 .5" (1 .27 cm)Decimal Point Three positions or none (1 .0 .0 .0)Display Color AmberDisplay Size 0 .5" (1 .27 cm)Range -1999 to 1999Operating Humidity 95% non-condensingOperating Temperature 32° to 122°F (0° to 50°C)Panel Clearance 1 .97" (5 .00 cm)Cutout Requirement 1 .00"H x 2 .40"W (2 .54 x 6 .10 cm)Dimensions Display 1 .11"H x 2 .51"W (2 .82 x 6 .38 cm) E (NEMA 4x) 6 .0"H x 6 .0"W x 3 .0"D (15 .2 x 15 .2 x 7 .62 cm) WMB 2 .12''H x 3 .12''W x 1 .75''D (5 .4 x 7 .94 x 4 .45 cm) DBL 6 .0"H x 6 .0"W x 3 .0"D (15 .2 x 15 .2 x 7 .62 cm) Approvals RoHSWeight 0 .14 lb (0 .06 kg) (Display only)Warranty 1 year

3-1/2 DIGIT LCD AMBER / GREEN / RED PANEL DISPLAYLPI-1C-A, LPI-1C-G, LPI-1C-R

DESCRIPTIONModels LPI-1CA, G, and R are 4-20 mA, 24 VDC-powered, brightly lit 3-1/2 digit color LCD displays, available with amber, green, or red digits . Models LPI-1CA, G, and R also feature jumper-selectable built-in engineering units of °F, °C, PSI, %, or no units . The same 24 VDC power supply can be used to provide power to the 4-20 mA loop and the display .

FEATURES• Indication of 4-20 mA signal in desired scale• Bright 3-1/2 digit LCD display• Available in amber, green, and red• Snap-in panel mounting• Easy-to-read digits• NEMA 4X enclosure available• Precalibrated for desired range• Negative-to-positive indication• Jumper selectable engineering unit display

Powersupply

24 VDC

Sensor/transmitter

BAS input orother 4-20 mA

load

-

+ -

+

ZERO

SPAN

+ - + -Factory calibrated

(no field calibration needed)

- +

Back of display unit

Board unit

°F°CPSI%

Connector pinsEngineering unit jumpersUnit selected displaysto the right of displayreading.

SIG B/L

4-20 mA

Connect the LPI-1C indicator in series with the 4-20 mA current loop to be measured.

WIRING

APPLICATION• Temperature• Humidity• Pressure

SPECIFICATIONS

ORDERING INFORMATION

LPI-1C-G-WMBLPI-1C-G

(typical panel mount)

• Differential or static pressure• Kilowatt demand• Gallons per minute• Voltage• Current• Many other 4-20 mA applications

LPI-1C-R-E LPI-1C-R-E-DBL

LPI-1C-A E-DBL Example: LPI-1C-A-E-DBL Two amber 3-1/2 digit LCD displays mounted in single enclosure

MODEL DESCRIPTIONLPI-1C-A 3-1/2 digit LCD with amber digits*LPI-1C-G 3-1/2 digit LCD with green digits*LPI-1C-R 3-1/2 digit LCD with red digits* – No enclosure E 3-1/2 digit LCD panel display with NEMA 4X enclosure WMB 3-1/2 digit LCD panel display with small enclosure E-DBL Two 3-1/2 digit LCD panel displays in one NEMA 4X enclosure

Displays are custom calibrated at no charge and require specification of input scale (mA), range, engineering units, and decimal point placement .

RELATED PRODUCTS PAGEDCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUT DCPA-1.2 Power supply, 120 VAC In to 24 VAC/24 VDC OutGP-3420 LPI-1C, LPI-3C, VPI-1C mounting goof plate, 3.40" x 2.00" (8.6 x 5.1 cm) 93,97-99GP-3430 LPI-1C, LPI-3C, VPI-1C mounting goof plate, 3.40" x 3.00" (8.6 x 7.6 cm) 93,97-99

Page 37: ALARMS & INDICATION

NEW!

99

ALARMS & INDICATIONALARM

S & INDICATION

2

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

NEW!

March 2014

Supply Voltage 24 VDC @ 35 mA for colored digitsInput Signal Loop-powered 4-20 mA signalInput Impedance 300Ω nominal @ 24 VDCAccuracy 0 .1% FSDigit Size 0 .5" (1 .27 cm) LCDDecimal Point Four positions or none (1 .0 .0 .0 .0)Range -19999 to +19999Operating Humidity 95% non-condensingOperating Temperature 32° to 122°F (0° to 50°C)Panel Clearance 1 .97" (5 .00 cm)Cutout Requirement 1 .00"H x 2 .40"W (2 .54 x 6 .10 cm)Dimensions Display 1 .11"H x 2 .51"W (2 .82 x 6 .38 cm) E (NEMA 4X) 6 .0"H x 6 .0"W x 3 .0"D

(15 .2 x 15 .2 x 7 .62 cm) WMB 2 .12''H x 3 .12''W x 1 .75''D

(5 .4 x 7 .94 x 4 .45 cm)Approvals RoHS, Except: (LPI-3CA)Weight 0 .14 lb (0 .06 kg) (Display only)Warranty 1 year

4-1/2 DIGIT BLACK / AMBER / GREEN / RED DISPLAYLPI-3C, LPI-3C-A, LPI-3C-G OR LPI-3C-R

DESCRIPTIONModel LPI-3C is a 4-20 mA, brightly lit, 4-1/2 digit display . Along with standard black digits, amber, green, and red (powered by 24 VDC) are also available . The Model LPI-3C also features jumper-selectable built-in engineering units of °F, °C, PSI, %, or no units . For those units with colored digits, the same 24 VDC power supply can be used to provide power to the 4-20 mA loop and the display .

FEATURES• Indication of 4-20 mA signal in desired scale• Optional, bright 4-1/2 digit LCD colored display• Available in black, amber, green, or red digits• Snap-in panel mounting• Easy-to-read digits• NEMA 4X enclosure available• Precalibrated for desired range• Negative-to-positive indication• Jumper-selectable engineering unit display

Power supply24 VDC

Sensor/transmitter

BAS inputor other

4-20 mA load4-20mA

ZEROSIG B/L

+ - + -

SPAN

Board unit

Display unit

Connector pinsFactory calibrated(no field calibration

required)

Power connection only requiredfor amber, green, or red display.

°F°CPSI%

Connect the LPI-3Cindicator in series with the 4-20 mAcurrent loop to be measured.

Engineering unit jumpersUnit selected displays to theright of display reading.

WIRING

APPLICATION

• Temperature• Humidity• Pressure• Differential or static pressure• Kilowatt demand• Gallons per minute• Voltage• Current• Many other 4-20 mA applications

SPECIFICATIONS

ORDERING INFORMATION

LPI-3C A E-DBL Example: LPI-3C-A-E-DBL Two amber 4-1/2 digit LCD displays mounted in a single enclosure.

MODEL DESCRIPTIONLPI-3C 4-1/2 digit LCD panel display* 4-1/2 digit display with black digits A 4-1/2 digit display with amber digits, (This unit not RoHS compliant) G 4-1/2 digit display with green digits R 4-1/2 digit display with red digits – No enclosure E 4-1/2 digit LCD panel display with NEMA 4X enclosure WMB 4-1/2 digit LCD panel display with small enclosure E-DBL Two 4-1/2 digit LCD panel displays in a single NEMA 4X enclosure

LPI-3C-A-WMBLPI-3C

(typical panel mount)

LPI-3C-G-E LPI-3C-R-E-DBL

Displays are custom calibrated at no charge and require specification of input scale (mA), range, engineering units, and decimal point placement .

RELATED PRODUCTS PAGEDCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUT DCPA-1.2 Power supply, 120 VAC In to 24 VAC/24 VDC OutGP-3420 LPI-1C, LPI-3C, VPI-1C mounting goof plate, 3.40" x 2.00" (8.6 x 5.1 cm) 93,97-99GP-3430 LPI-1C, LPI-3C, VPI-1C mounting goof plate, 3.40" x 3.00" (8.6 x 7.6 cm) 93,97-99

Page 38: ALARMS & INDICATION

ALARMS & INDICATION

100

ALAR

MS &

INDI

CATI

ON

2

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

NEW!

March 2014

Supply Voltage Black loop powered Red/Green/Amber 24 VDC @ 35 mA

Input Signal 4-20 mAInput Impedance 300ΩAccuracy ± 0 .05% of scale plus one digitDigit Count 3-1/2 digitsDigit Size 1" (2 .54 cm)Decimal Point Three positions or none (1 .0 .0 .0)Range -1999 to 1999Operating Humidity 95% non-condensingOperating Temperature 32° to 122°F (0° to 50°C)Cutout Requirement 1 .77" x 3 .62" (4 .5 X 9 .2 cm)Dimensions 1 .89"H x 3 .78"W x 1 .8"D (4 .8 x 9 .6 x 4 .6 cm)Approvals RoHSWeight 0 .25 lb (0 .11 kg)Warranty 1 year

DESCRIPTIONThe Model LPI-4 loop-powered indicator features a large 1" (2 .54 cm) 3-1/2 digit display . It is designed to display any 4-20 mA signal in desired scale . The Model LPI-4 is powered directly from the 4-20 mA signal loop, so there is no need for a power supply for the black digit model . It is also available in a 24 VDC powered version with red, green, or amber digits .

FEATURES• Indication of 4-20 mA signal in desired scale• 3-1/2 digit LCD display• Large, easy-to-read digits• Available in either black, red, green, or amber digits• Precalibrated for desired range• Snap-in panel mount with retainer• Negative range indicator• Includes weather-resistant seal• Optional jumper-selectable display units °F, °C, %, PSI

LPI-4

Power supply24 VDC

-

+ -

+

+ -

- +

SIG

SPAN ZERO

Sensor/transmitter

BAS inputor other

4-20 mA load

LPI-4R, G, A

Power supply24 VDC

-

+ -

+

+ -

- +

SIG+ -

B/L

SPAN ZERO

Sensor/transmitter

BAS inputor other

4-20 mA load

WIRING

APPLICATION• Temperature• Humidity• Pressure• Killowatt demand• Gallons per minute

KELE 3-1/2 DIGIT LARGE BLACK/RED/GREEN/AMBER PANEL DISPLAYLPI-4

SPECIFICATIONS

ORDERING INFORMATION

• Voltage/current

LPI-4

LPI-4G

LPI-4R

LPI-4A

MODEL DESCRIPTIONLPI-4 3-1/2 digit black panel displayLPI-4R 3-1/2 digit red panel displayLPI-4G 3-1/2 digit green panel displayLPI-4A 3-1/2 digit amber panel display

Displays are custom calibrated at no charge and require specification of input scale (mA), range, engineering units, and decimal point placement .

RELATED PRODUCTS DCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUT DCPA-1.2 Power supply, 120 VAC IN to 24 VAC/24 VDC OUT GP-5132 LPI-4 mounting goof plate, 5.13" x 3.25" (13.0 x 8.3 cm)

Page 39: ALARMS & INDICATION

NEW!

101

ALARMS & INDICATIONALARM

S & INDICATION

2

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

NEW!

March 2014

NEW!Supply Voltage 24 VDC @ 35 mAInput Signal 4-20 mAInput Impedance Black 300Ω Red 380ΩAccuracy ± 0 .1% of scale plus one digitDigit Count 3-1/2 digits maxDigit Size 0 .37" (0 .94 cm)Decimal Point Three positions of none (1 .0 .0 .0)Display Color Black, RedEngineering Units (Black only) MΩ, kΩ, °C, m, V, °F, A, μRange Black -1999 to 1999, min span 100 digit

counts

Red 0 to 1999 Operating Humidity 95% RH non-condensingOperating Temperature 32° to 130°F (0° to 54°C)Cutout Requirement Black 0 .86"H x 1 .57"W (2 .2 x 4 .0 cm) Red 0 .8"H x 1 .3"W (2 .0 x 3 .3 cm)Dimensions Black 0 .95"H x 1 .73"W x 1 .1"D (2 .4 x 4 .4 x 2 .8 cm) Red 1 .28"H x 1 .82"W x 1 .6"D (3 .25 x 4 .64 x 4 .0 cm)Approvals RoHSWeight 0 .13 lb (0 .06 Kg)Warranty 1 year

DESCRIPTIONThe LPI-5 loop-powered indicator features a small 0 .37" (0 .94 cm), 3-1/2 digit, black LCD or red LED display . The meter displays any 4-20 mA signal in desired scale . The Model LPI-5 is powered directly from the 4-20 mA signal loop, so the black LCD display and red LED display do not require a separate power supply .

FEATURES• Indication of 4-20 mA signal in desired scale• Loop powered• 3-1/2 digit display• Snap-in panel mounting• Small, easy-to-read display• Precalibrated for desired range• Selectable decimal point location• Positive-to-negative indication (black LCD display)

24 VDC Power supply

SIG

4-20 mASensor/transmitter

BAS inputor other

4-20 mA load

-+ -

+

- +

Factory calibrated(No field calibration needed)

LPI-5or

LPI-5R

WIRING

KELE 3-1/2 DIGIT SMALL BLACK/RED PANEL DISPLAYLPI-5

SPECIFICATIONS

LPI-5

LPI-5R

APPLICATION

• Temperature• Humidity• Pressure

• GPM• Kilowatt demand• Voltage/Current

ORDERING INFORMATION

MODEL DESCRIPTIONLPI-5 3-1/2 digit small black LCD panel displayLPI-5R 3-1/2 digit small red LED panel display

Displays are custom calibrated at no charge and require specification of input scale (mA), range, engineering units, and decimal point placement .

RELATED PRODUCTSDCPA-1.2 Power supply, 120 VAC IN to 24 VAC/24 VDC OUTDCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUT

Page 40: ALARMS & INDICATION

ALARMS & INDICATION

102

ALAR

MS &

INDI

CATI

ON

2

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014March 2014

Battery Life 10 years nominalInput Contact or solid-state switchCount Speed Accumulator 100 counts per second Timer counts One-hour or 0 .1-hour incrementsDigit Size 0 .2" (0 .51 cm) highDisplay 5-1/2 digitRange 0-199999

Reset Push button or remote contactOperating Temperature 32° to 122°F (0° to 50°C)Panel Cutout 1 .0"H x 2 .0"W (2 .54 x 5 .08 cm)Bezel 1 .1"H x 2 .09"W x 1 .72"D

(2 .79 x 5 .3 x 4 .37 cm)Weight 0 .13 lb (0 .06 Kg)Warranty 2 years

PULSE OR RUN-TIME ACCUMULATOR DISPLAYALD-1

DESCRIPTIONThe ALD-1 is a 5-1/2 digit LCD resettable accumulator or run-time counter . The lithium battery provides years of trouble-free service . Two wires are all that are necessary to totalize consumption, flow data, or run-time data . No external power supply is necessary .

FEATURES• Resettable accumulator or run-time counter• Long life lithium battery• No external power supply

SPECIFICATIONS

ORDERING INFORMATION

MODEL DESCRIPTIONALD-1 LCD push-button resettable accumulator counterALD-10C LCD run-time remote reset clock, one-hour incrementsALD-1C LCD run-time remote reset clock, 0.1-hour incrementsALD-1R LCD remote reset accumulator counter

WIRING

Run

Reset

Reset

Count

ALD-1RReset Wiring

(orange) (not used)

(+) (white)

(+) (blue)

(-) (orange/white)

(+) Cnt (white)

Rst (blue)

(-) Com (black)

N.O.

N.O.

SwitchContact

SwitchContact

ALD-1/RAccumulatorCounter

ALD-1C/10CRun TimeClock

GROUNDSHIPPING

ONLY

Page 41: ALARMS & INDICATION

NEW!

103

ALARMS & INDICATIONALARM

S & INDICATION

2

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

EDWARDS AUDIBLE AND VISUAL SIGNALSSIGNALING BASICS

BEACON TYPES AND THEIR APPLICATIONS

Rotating Beacons

Used to signal over a large area such as in airports,distribution centers and large process areas .

Flashing Beacons

Used to signal attention and equipment condition in processcontrol lines, airport baggage areas, and other areasrequiring human interface .

Double Flashing Beacons

Used to signal attention and equipment condition over wideareas . Sometimes used in lieu of Rotating Beacons .

Steady Beacons

Used to identify a continuous source or process .

Strobe Lights

Used for equipment status and malfunction indication overlarge and high noise areas .

Diode Supervised and UL 1971 Strobe Lights

Diode polarized strobes are used in electronicallysupervised alarm circuits . When the strobe has a UL 1971listing it may also be used in compatible fire alarm systemsas a signaling device for the hearing impaired .

LENS COLORS AND THEIR APPLICATIONSMost Edwards strobes, steady and flashing beacons come insix lens colors: amber, blue, clear, green, magenta and red .Edwards LED signals come in amber, blue, green, red and,in some cases, white . The following are examples of howvarious lens colors are used in industrial and commercialsignaling environments:

Amber

Denotes caution .

Blue

Used for safety and security .

Clear (or White) & Green

Used to indicate normal run operation .

Magenta

Used for radiation alarms .

Red

Denotes emergency or warning .

LIGHT SOURCES AND THEIRAPPLICATIONSEdwards signals use a variety of light sources: halogen,standard incandescent, LED, and strobe . The following is abrief overview of these type of light sources and their use .

LED

Use in areas where vibration resistance and long life are ofutmost concern . Light output with older technology LEDs isrelatively poor; newer technology LEDs have vastlyimproved light output but are still expensive .

Halogen

Use in areas where high light output and long life areconsiderations . Halogen light sources work well in highambient light areas . However, halogen bulbs tend to performunfavorably in high vibration environments .

Incandescent

Incandescent light sources are typically the mostinexpensive . They are often used in applications where costis a driving factor . Incandescent bulbs tend to have arelatively short life span . Their light output, while usuallysufficient, is less than that of a halogen or strobe .

Strobes

Strobes are known for their exceptional bright burst of lightenergy . A strobe light passes a brief, intense pulse of electriccurrent through a gas, which then emits a brilliant burst oflight . The gas is usually one of two inert gases, xenon orkrypton . Strobe lights are very vibration resistant and willfunction for thousands of hours before requiringreplacement .

CAT. NUMBER VOLTAGE SUFFIXESEdwards visual signals are available in a wide variety ofvoltages . Each signal has a catalog number suffix whichindicates the voltage of that specific signal . The following is alist of the cat . number suffixes and the voltages theyrepresent:

From the amber light of a rotating beacon at an airport to the double flash of a red strobe in a Division 2 area, Edwards providesthe widest array of visual signaling solutions in the industry . The following is a brief overview of some of the types of visualsignals and applications .

Suffix Voltage Suffix Voltage

-AQ 24V AC/DC -G5 24V AC 50/60 Hz

-E1 12V DC -GW 24-28V DC

-EK 12-48V DC -MP 72-125V DC

-FJ 20-30V DC -N5 120V AC 50/60 Hz

-FY 36V DC -R5 240V AV 50/60 Hz

-G1 24V DC -S1 250V DC

VISUAL SIGNALING BASICS BY EDWARDS SIGNALING

Page 42: ALARMS & INDICATION

ALARMS & INDICATION

104

ALAR

MS &

INDI

CATI

ON

2

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

AUDIBLE SIGNALING BASICS BY EDWARDS SIGNALING

EDWARDS AUDIBLE AND VISUAL SIGNALSSIGNALING BASICS

AUDIBLE SIGNALS AND THEIR APPLICATIONS

Vibrating and Single Stroke Bells

6", 8", and 10" bells are used for alarms over large areassuch as distribution centers . 4" bells are used for smallerapplications . Single stroke bells are most useful for pagingapplications .

Vibrating Horns

Used to signal attention and equipment condition in processcontrol lines and other areas requiring human interface .

Buzzers

Most often used for local annunciation of noncritical eventsbut can also be used when a distinctive paging signal isrequired .

Chimes

Suitable for relatively quiet locations to page or locallyannunciate .

Sirens and Outdoor Warning Signals

For use in general services and emergency warning overlarge geographic areas .

Multiple Tone Signals

Used in stand-alone and signaling systems that requiremultiple tone selectability and flexibility .

Voice Signals

Used where the delivery of specific instructions are required .

SOUND PRESSURE LEVELSSound pressure fluctuations diminish or “die out” with increasing distance from the sound source . A distance must generally be specified along with the dB rating to fully describe a sound . The sound pressure level changes 6 dB for each halving or doubling of distance . For a change in distance of ten times, the sound pressure level changes 20 dB .

TYPICAL DB LEVELS WHEN SELECTINGAUDIBLE SIGNALSIn specifying a signaling device, the above characteristicsshould be considered along with as many factors concerningthe application as can be gathered . Selecting the proper device for each signaling application need not be difficult if thefollowing points are observed .

1. Signal Function

Basically, the types of functions to which signals can be applied are: general alarm or emergency, start and dismissal,paging or coding, localized danger, and indication .The first step in selecting a signal is to carefully define thisfunction . Is the signal to be a warning, a call, or an instruction?Will it be used to protect life or property? How muchtime will be available to take action?

Obviously, the more critical the application, the more startlingthe signal generated must be . A horn is generally the moststartling signal . Its rasping tone commands immediate attention .A single stroke bell can be used for paging applicationswhere danger is not at hand . A small buzzer may serve tonotify a machine operator that a particular operation is completed .

2. Uniform Sound Distribution

Usually, better signal distribution can be achieved by carefullypositioning a number of smaller signals throughout a givenarea than by centrally locating a single large unit .

3. Ambient Sound Conditions

The frequency of the signaling device selected should be asdifferent from the background noise as possible . The signalshould override this noise by a minimum of six decibels . Usually,the noisier the area, the louder the signal required andthe greater the number required .

4. Size of Area to be Covered

The larger the area, the louder the signal required or thegreater the number of units required . Better coverage is frequentlyobtained by the use of several signals of lower dBrating than by the use of one very loud signal, providing thesignals can be positioned to advantage .

5. Mounting Considerations

The surface that the signal is mounted on can markedly affectthe signal’s performance . A horn, for example, should be rigidly mounted to a sturdy surface so that all of its energy is directed into the sound output and not absorbed by the wall . Abuzzer, however, can sound much louder if mounted on aresonant surface because it will act as a “sound board” for the device .

CAT. NUMBER VOLTAGE SUFFIXESEdwards audible signals are available in a wide variety ofvoltages . Each signal has a catalog number suffix whichindicates the voltage of that specific signal . The following is alist of the cat . number suffixes and the voltages theyrepresent:

Suffix Voltage Suffix Voltage

-AQ 24V AC/DC -G5 24V AC 50/60 Hz

-E1 12V DC -GW 24-28V DC

-EK 12-48V DC -MP 72-125V DC

-FJ 20-30V DC -N5 120V AC 50/60 Hz

-FY 36V DC -R5 240V AV 50/60 Hz

-G1 24V DC -S1 250V DC

From the soft melodic sound of a chime, to the ear piercing emergency blast of an outdoor warning signal, Edwards audiblesignals produce sounds that demand immediate attention .